• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 10
  • 2
  • 2
  • 1
  • Tagged with
  • 13
  • 7
  • 7
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Développement et optimisation des diagnostiques des faisceaux du LHC et du SPS basé sur le suivi de la lumière synchrotron / Development and Optimization of the LHC and the SPS Beam Diagnostics Based on Synchrotron Radiation Monitoring

Trad, Georges 22 January 2015 (has links)
La mesure de l’émittance transverse du faisceau est fondamentale pour tous les accélérateurs, et en particulier pour les collisionneurs, son évaluation precise étant essentielle pour maximiser la luminosité et ainsi la performance des faisceaux de collision.Le rayonnement synchrotron (SR) est un outil polyvalent pour le diagnostic non-destructif de faisceau, exploité au CERN pour mesurer la taille des faisceaux de protons des deux machines du complexe dont l’énergie est la plus élevée, le SPS et le LHC où l’intensité du faisceau ne permet plus les techniques invasives.Le travail de thèse documenté dans ce rapport s’est concentré sur la conception, le développement, la caractérisation et l’optimisation des moniteurs de taille de faisceau basés sur le SR. Cette étude est fondée sur un ensemble de calculs théoriques, de simulation numériques et d’expériences conduite au sein des laboratoires et accélérateurs du CERN. Un outil de simulation puissant a été développé, combinant des logiciels classiques de simulation de SR et de propagation optique, permettant ainsi la caractérisation complète d’un moniteur SR de la source jusqu’au détecteur.La source SR a pu être entièrement caractérisée par cette technique, puis les résultats validés par observation directe et par la calibration à basse énergie basée sur les mesures effectuées avec les wire-scanners (WS), qui sont la référence en terme de mesure de taille de faisceau, ou telles que la comparaison directe avec la taille des faisceaux obtenue par déconvolution de la luminosité instantanée du LHC.Avec l’augmentation de l’énergie dans le LHC (7TeV), le faisceau verra sa taille diminuer jusqu’à atteindre la limite de la technique d’imagerie du SR. Ainsi, plusieurs solutions ont été investiguées afin d’améliorer la performance du système: la sélection d’une des deux polarisations du SR, la réduction des effets liés à la profondeur de champ par l’utilisation de fentes optiques et l’utilisation d’une longueur d’onde réduite à 250 nm.En parallèle à l’effort de réduction de la diffraction optique, le miroir d’extraction du SR qui s’était avéré être la source principale des aberrations du système a été entièrement reconçu. En effet, la détérioration du miroir a été causée par son couplage EM avec les champs du faisceau, ce qui a conduit à une surchauffe du coating et à sa dégradation. Une nouvelle géométrie de miroir et de son support permettant une douce transition en termes de couplage d’impédance longitudinale dans le beam pipe a été définie et caractérisée par la technique dite du “streched wire”. Egalement, comme méthode alternative à l’imagerie directe, un nouveau moniteur basé sur la technique d’interférométrie à deux fentes du SR, non limité par la diffraction, a également été développé. Le principe de cette méthode est basé sur la relation directe entre la visibilité des franges d’interférence et la taille de faisceau.Comme l’emittance du faisceau est la donnée d’intérêt pour la performance du LHC, il est aussi important de caractériser avec précision l’optique du LHC à la source du SR. Dans ce but, la méthode “K-modulation” a été utilisée pour la première fois au LHC en IR4. Les β ont été mesurés à l’emplacement de tous les quadrupoles et ont été évalués via deux algorithmes de propagation différents au BSRT et au WS. / Measuring the beam transverse emittance is fundamental in every accelerator, in particular for colliders, where its precise determination is essential to maximize the luminosity and thus the performance of the colliding beams.
 Synchrotron Radiation (SR) is a versatile tool for non-destructive beam diagnostics, since its characteristics are closely related to those of the source beam. At CERN, being the only available diagnostics at high beam intensity and energy, SR monitors are exploited as the proton beam size monitor of the two higher energy machines, the Super Proton Synchrotron (SPS) and the Large Hadron Collider (LHC). The thesis work documented in this report focused on the design, development, characterization and optimization of these beam size monitors. Such studies were based on a comprehensive set of theoretical calculations, numerical simulations and experiments.A powerful simulation tool has been developed combining conventional softwares for SR simulation and optics design, thus allowing the description of an SR monitor from its source up to the detector. 
The simulations were confirmed by direct observations, and a detailed performance studies of the operational SR imaging monitor in the LHC, where different techniques for experimentally validating the system were applied, such as cross-calibrations with the wire scanners at low intensity (that are considered as a reference) and direct comparison with beam sizes de-convoluted from the LHC luminosity measurements.In 2015, the beam sizes to be measured with the further increase of the LHC beam energy to 7 TeV will decrease down to ∼190 μm. In these conditions, the SR imaging technique was found at its limits of applicability since the error on the beam size determination is proportional to the ratio of the system resolution and the measured beam size. Therefore, various solutions were probed to improve the system’s performance such as the choice of one light polarization, the reduction of depth of field effect and the reduction of the imaging wavelength down to 250 nm.In parallel to reducing the diffraction contribution to the resolution broadening, the extraction mirror, found as the main sources of aberrations in the system was redesigned. Its failure was caused by the EM coupling with the beam’s fields that led to overheating and deterioration of the coating. A new system’s geometry featuring a smoother transition in the beam pipe was qualified in terms of longitudinal coupling impedance via the stretched wire technique. A comparison with the older system was carried out and resulted in a reduction of the total power dissipated in the extraction system by at least a factor of four.A new, non-diffraction limited, SR-based monitor based on double slit interferometry was designed as well as an alternative method to the direct imaging. Its principle is based on the direct relation between the interferogram fringes visibility and the beam size.Since the beam emittance is the physical quantity of interest in the performance analysis of the LHC, determining the optical functions at the SR monitors is as relevant as measuring the beam size. The “K-modulation” method for the optical function determination was applied for the first time in the LHC IR4, where most of the profile monitors sit. The βs at the quadrupoles were measured and via two different propagation algorithms the βs at the BSRT and the WS were obtained reducing significantly the uncertainty at the monitors location.
12

Apports de l'interférométrie radar différentielle à la tectonique active de Taiwan

Pathier, Erwan 09 December 2003 (has links) (PDF)
L'île de Taiwan est le résultat de la collision, toujours active, des plaques Philippines et Eurasie. Ce travail a pour objet de mieux comprendre les processus tectoniques qui accompagnent la croissance actuelle de l'orogène, en utilisant l'interférométrie radar différentielle satellitaire en complément des autres méthodes d'investigation existantes. Cette technique fournit des cartes de déformation instantanée du sol (de quelques années à quelques jours) étendues, précises et denses. Après avoir détaillé les principes et les limites de cette mesure, ainsi que son potentiel à Taiwan, la technique est appliquée, avec des données issues des satellites ERS, à deux phénomènes tectoniques caractéristiques du développement de cette chaîne de collision. (1) Le séisme de Chi-Chi (1999, Mw = 7.6) sur la frontière Ouest de l'orogène, correspond à la réactivation de la faille chevauchante majeure de Chelungpu. L'interférométrie radar et le GPS permettent de quantifier avec une précision centimétrique les déformations cosismiques métriques affectant le bloc chevauché et d'y détecter les réactivations, induites par le choc principal, des failles de Changhua et de Tuntzuchiao. La comparaison avec les déplacements prédits par les modèles publiés de distribution de glissement sur la faille montre les limites de ces modèles. (2) Au SW de l'île, l'interférométrie radar permet la quantification de la croissance rapide (1,5 cm/an de 1993 à 2000) d'un anticlinal d'axe N-S, traduisant la propagation du front de déformation sur la marge continentale chinoise à l'Ouest. Ce phénomène tectonique est modélisé par une structure en "pop-up" limitée au nord par une rampe latérale, orientée E-W.
13

Etude ultra-sensible en phase de nano-structures par interferométrie optique à balayage en champ proche / A study on ultra-sensitive phase in nano-structures by near-field scanning optical interferometry

Mok, Jinmyoung 26 March 2015 (has links)
La construction d’un NSOM, dans ce manuscrit de thèse, est décrite en détail. Lacombinaison du système NSOM construit avec un interféromètre est proposée afin d’accéderà des mesures de phase, à la fois de ultra-haute sensibilité mais également de très granderésolution spatiale. Le nom de l’instrument développé est un interferomètre optique àbalayage en champ proche (NSOI, pour l’acronyme en anglais). Le principe est basé surl’utilisation d’un diapason accordable en cristal de quartz, sur lequel se trouve une pointe,afin de sonder le matériau étudié. La mesure de la force de cisaillement de la pointe sondeau voisinage de la surface permet d’assurer la régulation et la stabilité de la distance depositionnement de la pointe par rapport à la surface considérée. Le dispositif est construit encombinant différents éléments électroniques pilotés par un logiciel développé en langageLab-VIEW. Le bruit de la mesure en NSOI est supprimé par un calcul simple basé sur lathéorie de l’optique ondulatoire et des interférences associées. Le système permet deréaliser des mesures optiques en champ proche ainsi que la détermination en hauterésolution de la phase du champ optique. L’échantillon SNG01 (l’un des réseaux utilisés pourcaractériser notre microscope à balayage en champ proche), ainsi que des disques optiques(CD, DVD and disques blu-ray) ont été utilisés pour tester la faisabilité et les performancesde notre système.Dans ce manuscrit de thèse, le graphène et les monocouches de MoS2 sont étudiés. Nous montrons qu’une épaisseur à l’échelle atomique peut être résolue par notresystème NSOI, avec l’utilisation de l’algorithme de suppression du bruit de mesure. Lesjoints de grain du graphène sont observés à grande échelle, via la technique d’imagerie parcollection en champ proche et par la réalisation de cartographies de phase. En particulier,les tensions internes à une couche de graphène sont observées, uniquement dans le casd’une imagerie de phase. / In this thesis, near-field scanning optical interferometry (NSOI), which combinesNSOM with interferometer, is proposed for the phase measurement. The shear-forcedetection scheme is applied for distance regulation. The hardware of the systemis constructed by combining various electronic devices, and the operating softwareis coded by LabVIEW. Unwanted background signal is removed by simple calculationbased on interference theory. By using this, the near-field optical measurementand the ultra-sensitive phase investigation of nano-materials are performed. 2D materialssuch as graphene and monolayer MoS2 are investigated. It is shown thatatomic-scale thickness can be resolved by the NSOI. Especially, the grain boundariesof graphene and the seed of MoS2 can be found by phase detection. In addition,direct laser writing (DLW) on silver-containing glass is observed by using NSOM,and NSOI. For the first time, the writing threshold is correlatively observed in thefluorescence imaging and the near-field phase image.

Page generated in 0.0694 seconds