• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Moisture Content and Mould Risk in Concrete Outer Walls / Fuktinnehåll och Mögelrisk i Ytterväggar av Betong

Björnsdóttir, Jóhanna Eir, Jóhannsson, Jóhann Björn January 2018 (has links)
Previous studies on the typical Icelandic external wall have shown thatcondensation occurs at the interior surface of the concrete and field inspectionshave supported this conclusion. The primary objective ofthis study is to analyse the hygrothermal behaviour of the typical Icelandicwall and evaluate the mould risk at the interior surface of theconcrete.A comparative study is performed to compare the hygrothermalperformance and mould growth risk of two concrete outer wall structureswith interior and exterior insulation, by performing a parametricstudy using the simulation program WUFI® Pro.Additional parametric studies are performed in order to analyse theeffect of various material properties of the Icelandic building materialson the hygrothermal behaviour of the wall. This part also utilizedWUFI® Pro.To investigate the thermal bridge of the Icelandic wall, simulationswere conducted with the COMSOL Multiphysics software to evaluatethe linear thermal bridge and the risk of condensation at the joint.Lastly, an experiment was set up at the Innovation Center Iceland tomodel the interior insulated wall-slab section. The experimental setupwas completed during this time but the results will be analysedfurther after the thesis work.The results from this study indicate that the typical Icelandic wall ismore sensitive to rain than to interior moisture load and that no condensationoccurs within the wall structure. As concrete is inorganic,the risk of mould growth in the wall structure is limited, however,with increased driving rain load the mould risk increases. The resultsalso revealed that the moisture content of the interior insulated wallwas a great deal higher compared to the exterior insulated wall. Furthermore,the humidity level at the interior surface of the concrete inthe interior insulated wall exceeded the recommended critical humiditylevel based on general suggestions. Finally, results indicated thatusing a more dense concrete resulted in higher relative humidity at theinterior surface but a lower total water content of the wall.
2

Horský penzion / Mountain pension

Landecký, Tomáš January 2015 (has links)
The objective of this thesis is to create the documentation for building construction. Designed building is a mountain guesthouse. Building plat is located in the cadastral Poteč. Project documentation has been prepared in accordance with applicable laws, regulations and standards. The object is designed as one floor building with basement and residential loft and is fitted in sloping terrain. The building is shaped in layout L with the longest plane dimensions 40,11 x 39,05 m. Foundations are designed as strips of plain concrete. The building is designed as a wall support system. Wall system is combined of shuttering blocks filled with concrete, ceramic brick blocks and wood timbering. Roofed building is realized through the roof with a vertical stool. The ceiling above the ground floor is designed as a reinforced concrete slab ceiling and above the first floor as the timber.
3

CORNET: IN2EUROBUILD

Technische Universität 17 October 2024 (has links)
Der Heizenergieverbrauch in Bestandsgebäuden trägt erheblich zum gesamten Energieverbrauch und den CO2-Emissionen in Deutschland bei. Eine Reduktion dieses Verbrauchs ist essenziell für den Klimaschutz und wird durch energetische Sanierungen und den Erhalt von Gebäuden erreicht. Neben der Senkung der Heizkosten erhöhen solche Maßnahmen auch den Wohnkomfort und die Wertigkeit der Gebäude. Wenn eine Außendämmung nicht möglich ist, etwa aus Denkmalschutzgründen oder bei Sichtmauerwerk, ist Innendämmung eine Alternative, die schon vielfach erfolgreich eingesetzt wurde. Viele erprobte Systemlösungen stehen dafür zur Verfügung. Viele Innendämmmaßnahmen sind unkritisch und können mit Standardlösungen bewältigt werden, manche Maßnahmen erfordern dagegen Fachwissen. Die fachlich komprimierten Leitfäden sollen dabei helfen, kritische von unkritischen Fällen zu unterscheiden. Bei allen Arbeitsschritten unterstützen detaillierte Ablaufschemata. Für erfolgreiche Dämmmaßnahmen ist eine gründliche Begutachtung des Bauwerks notwendig, gefolgt von der Planung und Anbringung des Innendämmsystems. Im ersten Teil der vorliegenden Leitfadenreihe ‚Bauwerksanalyse‘ wurde deshalb zunächst auf die Bewertung und Zustandsanalyse von Bauwerken eingegangen. Übliche Bauschäden, die für einen langfristigen Erfolg der Sanierung unabhängig von einer Dämmmaßnahme behoben werden müssen, werden im ersten Teil beschrieben. Der zweite Teil der Leitfadenreihe ‚Fassadensanierung und Innendämmung‘ beschreibt die Erstellung eines Sanierungskonzepts und vermittelt ferner, was bei der Planung, Dimensionierung und Ausführung einer Innendämmmaßnahme beachtet werden muss. / Heating energy consumption in existing buildings contributes significantly to overall energy consumption and CO2 emissions in Germany. Reducing this consumption is essential for climate protection and is achieved through energy-efficient refurbishment and the preservation of buildings. In addition to reducing heating costs, such measures also increase living comfort and the value of the building. If external insulation is not possible, for example for reasons of monument protection or in the case of exposed brickwork, internal insulation is an alternative that has already been used successfully in many cases. Many tried and tested system solutions are available for this purpose. Many interior insulation measures are not critical and can be managed with standard solutions, while some measures require specialist knowledge. The professionally summarised guidelines are intended to help distinguish between critical and non-critical cases. Detailed flow charts provide support for all work steps Successful insulation measures require a thorough assessment of the building, followed by the planning and installation of the internal insulation system. The first part of this series of guidelines, 'Analysing buildings', therefore initially deals with the assessment and condition analysis of buildings. Common structural damage that must be repaired to ensure the long-term success of the refurbishment, regardless of insulation measures, is described in the first part. The second part of the series of guidelines, 'Façade refurbishment and internal insulation', describes the creation of a refurbishment concept and also explains what needs to be taken into account when planning, dimensioning and implementing an internal insulation measure.
4

CORNET: IN2EUROBUILD

Technische Universität 17 October 2024 (has links)
Der Heizenergieverbrauch in Bestandsgebäuden trägt erheblich zum gesamten Energieverbrauch und den CO2-Emissionen in Deutschland bei. Eine Reduktion dieses Verbrauchs ist essenziell für den Klimaschutz und wird durch energetische Sanierungen und den Erhalt von Gebäuden erreicht. Neben der Senkung der Heizkosten erhöhen solche Maßnahmen auch den Wohnkomfort und die Wertigkeit der Gebäude. Wenn eine Außendämmung nicht möglich ist, etwa aus Denkmalschutzgründen oder bei Sichtmauerwerk, ist Innendämmung eine Alternative, die schon vielfach erfolgreich eingesetzt wurde. Viele erprobte Systemlösungen stehen dafür zur Verfügung. Viele Innendämmmaßnahmen sind unkritisch und können mit Standardlösungen bewältigt werden, manche Maßnahmen erfordern dagegen Fachwissen. Die fachlich komprimierten Leitfäden sollen dabei helfen, kritische von unkritischen Fällen zu unterscheiden. Bei allen Arbeitsschritten unterstützen detaillierte Ablaufschemata. Für erfolgreiche Dämmmaßnahmen ist eine gründliche Begutachtung des Bauwerks notwendig, gefolgt von der Planung und Anbringung des Innendämmsystems. Im ersten Teil der vorliegenden Leitfadenreihe ‚Bauwerksanalyse‘ wurde deshalb zunächst auf die Bewertung und Zustandsanalyse von Bauwerken eingegangen. Übliche Bauschäden, die für einen langfristigen Erfolg der Sanierung unabhängig von einer Dämmmaßnahme behoben werden müssen, werden im ersten Teil beschrieben. Der zweite Teil der Leitfadenreihe ‚Fassadensanierung und Innendämmung‘ beschreibt die Erstellung eines Sanierungskonzepts und vermittelt ferner, was bei der Planung, Dimensionierung und Ausführung einer Innendämmmaßnahme beachtet werden muss. / Heating energy consumption in existing buildings contributes significantly to overall energy consumption and CO2 emissions in Germany. Reducing this consumption is essential for climate protection and is achieved through energy-efficient refurbishment and the preservation of buildings. In addition to reducing heating costs, such measures also increase living comfort and the value of the building. If external insulation is not possible, for example for reasons of monument protection or in the case of exposed brickwork, internal insulation is an alternative that has already been used successfully in many cases. Many tried and tested system solutions are available for this purpose. Many interior insulation measures are not critical and can be managed with standard solutions, while some measures require specialist knowledge. The professionally summarised guidelines are intended to help distinguish between critical and non-critical cases. Detailed flow charts provide support for all work steps Successful insulation measures require a thorough assessment of the building, followed by the planning and installation of the internal insulation system. The first part of this series of guidelines, 'Analysing buildings', therefore initially deals with the assessment and condition analysis of buildings. Common structural damage that must be repaired to ensure the long-term success of the refurbishment, regardless of insulation measures, is described in the first part. The second part of the series of guidelines, 'Façade refurbishment and internal insulation', describes the creation of a refurbishment concept and also explains what needs to be taken into account when planning, dimensioning and implementing an internal insulation measure.

Page generated in 0.1503 seconds