• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 1
  • Tagged with
  • 16
  • 16
  • 10
  • 10
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do uso de inversor de frequência em estação elevatória de água

Cherem, Lucas Braga 24 June 2016 (has links)
A energia elétrica é fundamental para o desenvolvimento do saneamento básico, com este setor representando 2,40% do consumo de energia elétrica no Brasil no ano de 2015. No panorama atual buscar alternativas de eficiência energética é fundamental tanto para redução no consumo de energia, causando assim um menor impacto ambiental, como para a redução de custos para as empresas responsáveis pelo saneamento, melhorando assim seu desempenho. Neste contexto o objetivo deste trabalho foi a avaliação de uma técnica de eficiência energética em sistemas de bombeamento. Utilizou-se um inversor de frequência para variar a rotação do motor com o objetivo de reduzir a vazão em comparação ao uso de uma válvula controladora de vazão. A análise foi feita em um sistema de abastecimento de água no município de Palmas-TO onde um motor de 100 cv era acionado por uma chave soft starter. O estudo de caso monitorou a potência, vazão, pressão, volume de água bombeado e o consumo de energia do sistema em questão, e possibilitou comprovar a eficiência do uso do inversor de frequência visto que o houve um ganho representativo no rendimento do sistema, além de uma redução de aproximadamente 22% no consumo de energia após sua implementação. Conclui-se que em sistemas onde há restrição de vazão feitas por válvulas, há viabilidade econômica para aplicação de um inversor de frequência, e que o investimento necessário para essa alteração, retorna para o investidor por meio da economia com o consumo de energia elétrica. Para este caso foi calculado um pay back de 10 meses. / Electricity is primordial for basic sanitation development, and this sector was responsible for 2.4% of Brazilian energy consumption in 2015. In our recent scenario, seeking for more energetic efficient processes is mandatory for reducing the environmental impact as well as costs incurred from a lower energy consumption for companies responsible for public sanitation. The objective of this current study was the evaluation of energetic efficiency technique for pumping systems. A Variable Frequency Drive was installed to vary the engine rotation aiming to reduce the flow rate when compared to the standard usage of a flow control valve. The analysis was made on a system of water supply in the municipality of Palmas-TO where a 100hp motor was ignited by a soft starter. This study monitored the following parameters: power, flow rate, pressure, pumped water volume and system energy consumption; this allowed proving the efficiency of the usage of the variable frequency drive which increased the system yield as well as reduced energy consumption in approximately 22%. It was then concluded that on systems where there are flow rate restrictions by valves it is economically feasible to install a variable frequency drive and the payback for the initial investment will come in power savings, to the case in question the payback is 10 months.
2

Sistema de Balanceamento Dinâmico Embarcado nos Controladores dos Poços de Produção por Bombeio Mecânico

Oliveira, Natalia Lima de 16 September 2015 (has links)
Submitted by Marcos Samuel (msamjunior@gmail.com) on 2017-02-06T15:18:32Z No. of bitstreams: 1 Dissertação_Natalia_versaofinal_CD.pdf: 2740629 bytes, checksum: 2ad0d4cbbf049e9e14424691d159d518 (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2017-02-06T16:10:18Z (GMT) No. of bitstreams: 1 Dissertação_Natalia_versaofinal_CD.pdf: 2740629 bytes, checksum: 2ad0d4cbbf049e9e14424691d159d518 (MD5) / Made available in DSpace on 2017-02-06T16:10:18Z (GMT). No. of bitstreams: 1 Dissertação_Natalia_versaofinal_CD.pdf: 2740629 bytes, checksum: 2ad0d4cbbf049e9e14424691d159d518 (MD5) / A Unidade de Bombeio Mecânico (UBM) é um dos equipamentos mais utilizados na produção de petróleo. Ele sofre com efeitos de desbalanceamento devido às características das cargas aplicadas e aos desgastes mecânicos causados ao longo do tempo por conta do esforço repetitivo que exerce. O desbalanceamento dos equipamentos é um dos principais efeitos usualmente estudados pela academia e indústria em função do grande impacto que provocam na durabilidade dos equipamentos. Este trabalho propõe um sistema capaz de balancear dinamicamente uma UBM através de algoritmos embarcados no controlador lógico programável do inversor de frequência, utilizado no controle de UBMs automatizadas. Para a detecção do desbalanceamento, duas formas indiretas de avaliar esse efeito foram abordados: o Fator de Carga Cíclica (CLF – Ciclic Load Factor) e análise de vibrações, através da Transformada Discreta de Fourier, ambos utilizando a variável torque. O CLF foi o critério escolhido para validação experimental do sistema. Em uma abordagem convencional, o CLF é calculado a cada ciclo de bombeio, mas tal estratégia não permite a atuação para o controle instantâneo da velocidade, que deve ser baseado na minimização do CLF. Para tanto, este trabalho propõe a aplicação de conceito baseado em janela deslizante, permitindo o cálculo de CLF a cada nova amostra. Esta abordagem permitiu também superar as limitações encontradas nos sistemas de inversão de frequência necessários à implementação da solução proposta neste trabalho. A atuação no controle de velocidade do motor usado no sistema de bombeio mecânico naturalmente pode interferir a capacidade do sistema de bombeio. Uma avaliação dessa capacidade foi implementada de forma a demonstrar a aplicabilidade do método de controle de desbalanceamento. Os resultados alcançados mostram que o sistema desenvolvido é capaz de minimizar o CLF através de um controle de velocidade, essencialmente, sem perda na capacidade do sistema de bombeio. Os testes foram realizados em bancada e validados na planta disponibilizadas pelo Laboratório de Elevação Artificial da Universidade Federal da Bahia
3

MONITORAMENTO E CONTROLE DO BALANCEAMENTO DE UNIDADE DE BOMBEIO MECÂNICO USANDO INVERSOR DE FREQUÊNCIA E FATOR DE CARGA CÍCLICA

Paula, Cicero ALexandre Brandão de 16 March 2012 (has links)
Submitted by Kleber Silva (kleberbs@ufba.br) on 2017-02-06T17:30:55Z No. of bitstreams: 1 Cícero.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2017-02-07T12:25:49Z (GMT) No. of bitstreams: 1 Cícero.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / Made available in DSpace on 2017-02-07T12:25:49Z (GMT). No. of bitstreams: 1 Cícero.pdf: 2013213 bytes, checksum: d134e81af3b53e4027c70fb34e1eb13f (MD5) / O desbalanceamento é inerente ao funcionamento de uma unidade de bombeio (UB). Para reduzir seus efeitos, o contrabalanceio é uma das ações que precisa ser adotada. Para atingir o balanceamento ideal é preciso buscar o equilíbrio entre os torques requerido pela haste polida e o torque fornecido pelo redutor durante o ciclo de bombeio. O objetivo principal deste trabalho é utilizar informações extraídas de medições realizadas da tensão no barramento DC de inversores de frequência, visando, promover o balanceamento das forças que atuam nesse equipamento. O balanceamento ótimo de uma unidade de bombeio mecânico foi alcançado, medindo esta variável, determinando o fator de carga cíclica (CLF), promovendo o ajuste na posição dos contrapesos e manipulando a velocidade de bombeamento. Para isto, faz-se necessário conhecer os principais métodos utilizados para contrabalancear a UB. Também foi preciso determinar o CLF por meio da tensão do barramento DC. Além disso, um controlador de tensão elétrica foi projetado e implantado em um controlador (CLP), sendo seu propósito reduzir a variabilidade da tensão no barramento do inversor. Como resultados, se tem uma redução significativa na potência consumida, em função do rendimento energético do motor que foi elevado. A variação do torque foi reduzida drasticamente, contribuindo pra uma operação mais suave do sistema, o que certamente irá elevar o tempo médio entre falhas (MTBF). Estes resultados levaram a melhoria do rendimento energético e da confiabilidade do sistema.
4

Diagnóstico energético de instalações de bombeamento de água – Estudo de caso / Energetic diagnosis for a water pumping station – Case study

Sampaio, Ricardo Petrillo 21 October 2005 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-03-09T13:15:55Z No. of bitstreams: 1 texto completo.pdf: 210013 bytes, checksum: 009aeeb827af39a84734f768c7405b0f (MD5) / Made available in DSpace on 2017-03-09T13:15:55Z (GMT). No. of bitstreams: 1 texto completo.pdf: 210013 bytes, checksum: 009aeeb827af39a84734f768c7405b0f (MD5) Previous issue date: 2005-10-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Estações de captação de água para abastecimento de cidades têm a função de retirar a água de seu curso natural ou de um reservatório e transportá-la a uma estação de tratamento. Sabe-se que quase a totalidade da energia consumida é para o funcionamento dos conjuntos motobombas, sendo, portanto, importante conhecer o funcionamento destas máquinas, portanto se faz necessários estudos que objetivam a integração dos dimensionamentos elétricos e hidráulicos, com a avaliação do impacto da qualidade de energia e da automação de estações de captação de água. Tudo isso visando a economia de energia, o controle e a supervisão do sistema e à minimização dos impactos da variação do sinal elétrico. O objetivo geral deste trabalho foi de desenvolver metodologia de diagnóstico energético de instalações de captação de água. Para tal foi estudado e simulado as instalações de captação de água do Serviço Autônomo de Água e Esgoto de Viçosa – SAAE, Viçosa, MG. Para o gerenciamento energético de qualquer instalação é requerido o pleno conhecimento dos sistemas energéticos existentes. Sendo assim, avaliou-se a energia elétrica fornecida pela concessionária em relação ao nível e desbalanceamento do sinal de tensão da rede, o uso adequado do consumo de energia elétrica na estação de captação, e a caracterização das cargas, incluindo: (i) potência nominal e potência em uso; (ii) tensão nominal e de fornecimento; (iii) corrente em função da carga e da tensão de fornecimento; (iv) horas de funcionamento anual; (iv) regime de trabalho (v) procedimentos operacionais, como a forma de partida; e (vi) potência hidráulica útil. A partir destes conhecimentos dimensionou-se individualmente a bomba, o motor elétrico e o conjunto motobomba e com isto foi possível realizar a simulação do consumo e da demanda de energia elétrica para o sistema corretamente dimensionado e simulação de tarifa de energia elétrica ideal para contratação. Concluíu-se que em relação a qualidade da tensão o potencial de economia de energia foi pequeno pois a tensão se encontrou dentro dos padrões, 98,26% na fase A, 97,36% na fase B e 72,36% na fase C e com esta variação de tensão encontrada obteve-se uma diferença final no rendimento de 0,36% na pior situação, portanto devendo-se trabalhar com a tensão na qualidade fornecida sem mexer na estrutura instalada, já em relação a adequação de força motriz e de bombas verificou-se um grande potencial de economia de energia pois na planta atual havia bombas com um rendimento muito baixo e apenas a troca da bomba e do motor no conjunto dois poderia-se obter uma economia de 16,8% apenas no consumo de energia elétrica e na adequação tarifaria verificou-se um grande potencial de economia de energia, pois no contrato atual tem-se bombas com rendimento muito baixo e tarifas não adequadas a situação. O sistema proposto necessitava de um manejo adequado, que permitiria-se chegar a uma economia financeira de 48,18% em todo o sistema. / The water pumping stations for supplying the localities operate by removing the water from its natural course or a reservoir and transporting it to the treatment plant. It is well-known that almost the total consumed energy is to the operation of the power pumping sets, therefore is important to know the operation of these machines. Thus, there is a need for studies that aim the integration of the electric and hydraulic dimensioning, such as, the evaluation of the impact of the energy quality and automation of the water pumping stations, on the energy economies, control and supervision of the system, as well as to the minimization of the impacts from the variation in electric sign. In this context, the present study was carried out to diagnose energetically a water pumping station, as well as to develop a methodology to accomplish the energetic diagnosis in the water pumping system of the Serviço Autônomo de Água e Esgoto de Viçosa – SAAE, Viçosa -MG. The energy management in any facility requires the complete knowledge of the existing energetic systems. Then, the electric power supplied by the utility is evaluated, relative to the level and imbalance of the network tension sign, whereas the way the electric power is consumed in the water pumping station is studied, by surveying the characteristics of each electric charge, as including: (i) nominal power and power in use; (ii) both nominal and supplied tensions; (iii) current as a function of the load and supplied tension; (iv) yearly operating hours; (iv) work regime; (v) operational procedures, as a starting way; and (vi) effective hydraulic power. Based on this knowledge, the dimensioning were only performed for the pump, the electric motor and both. So, it was possible to simulate the consumption and demand of the electric power for the correctly dimensioned system and to simulate the tariff of the ideal electric power for contract. It is concluded that in relation to tension quality, the energy economy potential is low because the tension is within the standards for 98.26% of the cases at phase A, 97.36% at phase B and 72.36% at phase C, and this variation in the tension provides a final difference of 0.36% in efficiency under the worst situation. Thus, it is advised to work with the tension under the supplied quality, so maintaining the structure as it really is. In relation to the adequacy of the engine power and pumps, a high potential for energy economy is verified, since there are low efficient pumps in the current project, so just changing the pump and engine in set 2 might provide an economy of around 16.8% in the consumption. Concerning to tariff adequacy, there is a high potential for energy economy, since in the current contract the pumping system shows a very low efficiency as well as tariffs not appropriate to the situation. The proposed system needs an adequate management, as an economy of 48.18% in the whole system might be obtained. / Dissertação importada do Alexandria
5

Avaliação da eficiência energética de uma bomba hidráulica uti-lizada em uma plataforma de descarga de grãos / Analysis of Energy Efficiency of a Hydraulic Pump in a Discharged Platform Used in Agroindustry

Figueiredo, João Luiz Fontana de 08 March 2018 (has links)
Submitted by Rosangela Silva (rosangela.silva3@unioeste.br) on 2018-06-25T23:49:50Z No. of bitstreams: 2 Joao_Luiz_ Fontana_Figueiredo.pdf: 3144216 bytes, checksum: 115906953fe12769294f97e9078a752d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-06-25T23:49:50Z (GMT). No. of bitstreams: 2 Joao_Luiz_ Fontana_Figueiredo.pdf: 3144216 bytes, checksum: 115906953fe12769294f97e9078a752d (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-08 / The population advances quickly in the regard to the increase in consumption energy in many forms. Brazil, considered the "breadbasket of the world", has innumerable grain storage units in his territory, and these, consume a lot of energy in their reception, drying and storage processes. Particularly in the process of receiving grains, there is a large energy consumption in the discharged platforms responsible for receiving the products in bulk. These discharged platforms are operated by hydraulic pumps driven by an electric motor, which operates uninterruptedly throughout the basculation pro-cess. The present work aims to perform a study of energy efficiency in the basculation system of the discharged platform, from the use of electric devices to control the oper-ation of the engine. For this purpose, two scenarios were established. The first sce-nario considers the platform in its current state, with engine starting made by a star-triangle key. In the second scenario, star-delta start is switched off, and a frequency inverter and a programmable logic controller (PLC) are coupled to control the electric motor. For the two scenarios, the active and reactive energy consumptions were meas-ured in the discharged platform using an energy analyzer, and the costs of the energy consumed in the period of one year were calculated. Finally, the discounted Payback was calculated to evaluate the economic feasibility of installing the proposed equip-ment. The results obtained were as follows: For the current scenario, the energy used to raise a ton was 35.44.10-3 kWh/ton, for the proposed scenario, with a frequency inverter, this index was 32.78.10-3 kWh/ton. With an annual projection, the current sce-nario would consume the equivalent of 10,921.35 kWh and the proposed scenario 10,100.81 kW, generating an annual savings with equipment installation of R$721.49, and the discounted Payback found of approximately 31 years. It can be concluded, therefore, that there is a reduction of electric energy consumption from the use of the frequency inverter, but the time of return of the invested capital is very long, making the proposal economically unfeasible. / A população avança a cada dia no tocante ao aumento do consumo de energia, nas suas mais variadas formas. O Brasil, considerado o “celeiro do mundo”, possui inúme-ras unidades de armazenamento de grãos em seu território, as quais, por sua vez, consomem energia significativa em seus processos de recepção, secagem e armaze-nagem. Particularmente, no processo de recepção de grãos, existe um grande con-sumo de energia nas plataformas de descarga responsáveis por receber os produtos a granel. Essas plataformas de descarga são operadas por bombas hidráulicas, aci-onadas por um motor elétrico, que opera de forma ininterrupta durante todo o processo de basculamento. O presente trabalho visa realizar um estudo de eficiência energé-tica, no sistema de basculamento da plataforma de descarga, a partir da utilização de dispositivos elétricos para controle do funcionamento do motor. Para tal finalidade, foram estabelecidos dois cenários. O primeiro cenário considera a plataforma em seu estado atual, com partida do motor feita por uma chave estrela-triângulo. No segundo cenário, a partida com chave estrela-triângulo é desligada e são acoplados um inver-sor de frequência e um controlador lógico programável (CLP), para fazer o controle do motor elétrico. Para os dois cenários, foram medidos os consumos de energia ativa e reativa na plataforma de descarga, utilizando um analisador de energia; além disso, foram calculados os custos da energia consumida, no período de um ano. Por fim, foi calculado o Payback, descontado para avaliar a viabilidade econômica da instalação dos equipamentos propostos. Os resultados obtidos foram os seguintes: Para o cená-rio atual, a energia gasta para bascular uma tonelada foi de 35,44.10-3 kWh/ton; para o cenário proposto, com inversor de frequência, o índice foi de 32,78.10-3 kWh/ton. Realizando uma projeção anual, o cenário atual consumiria o equivalente a 10.921,35 kWh; diante do cenário proposto, o índice foi de 10.100,81 kW, gerando uma econo-mia anual, com a instalação dos equipamentos, de R$721,49; o Payback descontado encontrado foi de 31 anos aproximadamente. Pode-se concluir, portanto, que existe uma redução de consumo de energia elétrica a partir da utilização do inversor de fre-quência, porém, o tempo de retorno do capital investido é muito longo, tornando a proposta inviável economicamente.
6

Estudo do motor de indução linear utilizado como posicionador e simulações computacionais / not available

Martins Filho, Geraldo Macias 24 April 2003 (has links)
Desde a idealização das máquinas elétricas girantes, o motor de indução linear (MIL) fora também considerado viável e, ao longo do tempo, foi pesquisado e foram desenvolvidas novas tecnologias para sua melhoria e para o seu acionamento. Muitos trabalhos acadêmicos foram realizados em todos os centros de pesquisa do mundo e, no Brasil, os primeiros a estudá-lo com rigor científico foram os professores Morency Arouca e Délio Pereira Guerrini, no início da década de 70, no departamento de Engenharia Elétrica da EESC/USP. Até hoje no Brasil, pouco se desenvolve neste campo de estudo da Engenharia Elétrica e, quando se desenvolve, ficam restritos à simulações e levantamentos de parâmetros característicos aos MIL\'s específicos. O presente trabalho tem como objetivo fazer uma explanação teórica e matemática que servirá de base ao estudo e compreensão do MIL e propor uma aplicação ao mesmo: o MIL acionado por inversor de freqüência e utilizado para obtenção de posicionamento com auxílio de simulação computacional de algumas malhas de controle para tal posicionamento. / Since the rotating machines had been idealized, the Linear Induction Motor (LIM) has been researched and, along the time, new technologies are being developed in order to improve it. Many academic works were accomplished in several research centers and universities around the world. In Brazil, the first ones to study it with scientific approach were Professors Morency Arouca and Délio Pereira Guerrini, in the early 70\'s. Even nowadays, works are seldom developed, and most of them are dedicated to simulation of the LIM or obtaining of parameters of specific LIM\'s. The present work has as objective to study the mathematical and theoretical modeling, which will be used as basis in order to study and understand the LIM and to propose an application: the LIM fed by Frequency Inverter, used in order to obtain positioning, with simulation of specific control systems.
7

Metodologia para avaliação da influência de geradores distribuídos nos níveis de curto-circuito em sistemas de distribuição de energia / Methodology for assessment of distributed generators Influence on short circuit levels of power distribution systems

Petean, Daniel 27 February 2015 (has links)
A instalação de geração distribuída nas redes de distribuição e de subtransmissão de energia elétrica tem apresentado significativo crescimento em âmbito mundial, impulsionada pelos benefícios que pode proporcionar aos sistemas elétricos, pela necessidade de diversificação da matriz energética dos países, pela desregulamentação do setor de energia elétrica em diversos países e pela necessidade de gerar energia elétrica de forma sustentável. No entanto, para que os geradores distribuídos possam de fato beneficiar a operação das redes elétricas, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, destaca-se a elevação do nível de curto-circuito da rede, pois correntes de curto-circuito com valores elevados podem causar violação das capacidades dos equipamentos em suportar os esforços térmicos e dinâmicos e também provocar a perda da coordenação entre os dispositivos de proteção contra sobrecorrente. Neste contexto, este trabalho analisa a influência de geradores distribuídos baseados em inversores na corrente de curto-circuito trifásica em um sistema de distribuição de energia, e sobretudo, comprova que sua contribuição no valor da corrente de falta não supera o dobro de sua corrente nominal. Além disso, com base nesta comprovação, apresenta duas estratégias para inserção desse tipo de gerador nos cálculos de curto-circuito de um sistema de distribuição de energia elétrica. As duas estratégias apresentam resultados satisfatórios, utilizam conceitos básicos de circuitos elétricos, independem de dados minuciosos dos inversores e são validadas através de aplicações numéricas com resultados confrontados aos obtidos das simulações. / The installation of distributed generation in distribution and subtransmission systems has shown significant growth worldwide, driven by the benefits it can provide to electrical systems, the need to diversify the energy sources, deregulation of the electricity industry in several countries and the need to generate electricity in a sustainable manner. However, in order to evaluate if distributed generators benefit the operation of power networks, their technical impacts should be carefully studied, especially in distribution networks, which were originally designed to operate with unidirectional power flow. Among the aforementioned impacts, there is the increase of the short circuit level in the distribution network, since high short-circuit currents may exceed the capabilities of equipment to support the dynamic and thermal stresses and also cause loss of coordination between the overcurrent protection devices. Within this context, this thesis analyzes the influence of inverter based distributed generators on three-phase short circuit currents in a power distribution systems. Especially it confirms that the contribution to the fault current does not exceed twice its rated value. Furthermore, based on this issue, this work presents two strategies for the inclusion of this type of generator in short circuit calculations. Both strategies presented satisfactory results, use basic concepts of electrical circuits, they do not depend on detailed data from the inverters and the results are validated by using simulation results.
8

Metodologia para avaliação da influência de geradores distribuídos nos níveis de curto-circuito em sistemas de distribuição de energia / Methodology for assessment of distributed generators Influence on short circuit levels of power distribution systems

Daniel Petean 27 February 2015 (has links)
A instalação de geração distribuída nas redes de distribuição e de subtransmissão de energia elétrica tem apresentado significativo crescimento em âmbito mundial, impulsionada pelos benefícios que pode proporcionar aos sistemas elétricos, pela necessidade de diversificação da matriz energética dos países, pela desregulamentação do setor de energia elétrica em diversos países e pela necessidade de gerar energia elétrica de forma sustentável. No entanto, para que os geradores distribuídos possam de fato beneficiar a operação das redes elétricas, seus impactos técnicos devem ser cuidadosamente estudados, sobretudo em redes de distribuição, as quais foram inicialmente planejadas para operar com fluxo de potência unidirecional. Dentre esses impactos, destaca-se a elevação do nível de curto-circuito da rede, pois correntes de curto-circuito com valores elevados podem causar violação das capacidades dos equipamentos em suportar os esforços térmicos e dinâmicos e também provocar a perda da coordenação entre os dispositivos de proteção contra sobrecorrente. Neste contexto, este trabalho analisa a influência de geradores distribuídos baseados em inversores na corrente de curto-circuito trifásica em um sistema de distribuição de energia, e sobretudo, comprova que sua contribuição no valor da corrente de falta não supera o dobro de sua corrente nominal. Além disso, com base nesta comprovação, apresenta duas estratégias para inserção desse tipo de gerador nos cálculos de curto-circuito de um sistema de distribuição de energia elétrica. As duas estratégias apresentam resultados satisfatórios, utilizam conceitos básicos de circuitos elétricos, independem de dados minuciosos dos inversores e são validadas através de aplicações numéricas com resultados confrontados aos obtidos das simulações. / The installation of distributed generation in distribution and subtransmission systems has shown significant growth worldwide, driven by the benefits it can provide to electrical systems, the need to diversify the energy sources, deregulation of the electricity industry in several countries and the need to generate electricity in a sustainable manner. However, in order to evaluate if distributed generators benefit the operation of power networks, their technical impacts should be carefully studied, especially in distribution networks, which were originally designed to operate with unidirectional power flow. Among the aforementioned impacts, there is the increase of the short circuit level in the distribution network, since high short-circuit currents may exceed the capabilities of equipment to support the dynamic and thermal stresses and also cause loss of coordination between the overcurrent protection devices. Within this context, this thesis analyzes the influence of inverter based distributed generators on three-phase short circuit currents in a power distribution systems. Especially it confirms that the contribution to the fault current does not exceed twice its rated value. Furthermore, based on this issue, this work presents two strategies for the inclusion of this type of generator in short circuit calculations. Both strategies presented satisfactory results, use basic concepts of electrical circuits, they do not depend on detailed data from the inverters and the results are validated by using simulation results.
9

Identificação de falhas elétricas em motores de indução trifásicos por injeção de sinal de referência / Identification of electrical faults in three-phase induction motors by reference signal Injection

Gongora, Wylliam Salviano 06 May 2019 (has links)
As máquinas elétricas rotativas são hoje a principal forma de transformação da energia elétrica em mecânica motriz e os motores de indução trifásicos têm grande relevância dentro do setor produtivo. A garantia de um correto funcionamento torna-se vital para eficácia e competitividade da empresa dentro do setor fabril. Assim sendo, um correto diagnóstico e classificação de falhas de funcionamento dos motores em operação pode fornecer maior segurança no processo de tomada de decisão sobre a manutenção, aumentar a produtividade e eliminar os riscos e os danos aos processos como um todo. A proposição deste trabalho baseia-se na análise das correntes de estator no domínio da frequência com sinais injetados na máquina juntamente com a modulação de alimentação para o diagnóstico do motor sem defeitos, com falhas de curtocircuito nos enrolamentos do estator e com falhas de rotor. A proposta é validada numa ampla faixa de frequências de operação bem como de regimes de conjugado de carga. São analisados os desempenhos individuais de cinco técnicas de classificadores de padrões, sendo proposta a utilização de: i) Perceptron Multicamadas, ii) Máquina de Vetores de Suporte, iii) k-Vizinhos Próximos, iv) Árvore de Decisão C 4.5 e v) Naive Bayes. Complementarmente, é desenvolvido um comparativo dos métodos de classificação de padrões para avaliar a precisão de classificação frente aos diversos níveis de severidade das falhas. Resultados experimentais com motor de 1 cv são apresentados para validar a proposta. / Rotating electric machines are today the main form of transformation of electrical energy in motor mechanics and three-phase induction motors have great relevance within the productive sector. Thus a correct diagnosis and classification of failures of the engines in operation can provide security in the decision making process on maintenance, increase productivity and eliminate risks and damages to processes as a whole. The purpose of this paper is based on the analysis of the stator currents in the frequency domain with signals injected into the machine together with the power modulation for the diagnosis of motor faultless, stator winding short-circuit faults and rotor faults. Considering also, for validation of the proposal is validated on a broad range frequency of operation as well as load torque. We analyze the individual performances of five standard classifier techniques, proposing the use of: i) Multilayers Perceptron, ii) Support Vector Machine, iii) k-Nearest Neighbor, iv) C 4.5 Decision Tree and v) Naive Bayes. Complementarily, a comparison of the methods of classification of standards is developed to evaluate the accuracy of classification against the different levels of severity of the failures. Experimental results with 735.5 w and 1.471 w engines are presented to validate the proposal.
10

Estudo do motor de indução linear utilizado como posicionador e simulações computacionais / not available

Geraldo Macias Martins Filho 24 April 2003 (has links)
Desde a idealização das máquinas elétricas girantes, o motor de indução linear (MIL) fora também considerado viável e, ao longo do tempo, foi pesquisado e foram desenvolvidas novas tecnologias para sua melhoria e para o seu acionamento. Muitos trabalhos acadêmicos foram realizados em todos os centros de pesquisa do mundo e, no Brasil, os primeiros a estudá-lo com rigor científico foram os professores Morency Arouca e Délio Pereira Guerrini, no início da década de 70, no departamento de Engenharia Elétrica da EESC/USP. Até hoje no Brasil, pouco se desenvolve neste campo de estudo da Engenharia Elétrica e, quando se desenvolve, ficam restritos à simulações e levantamentos de parâmetros característicos aos MIL\'s específicos. O presente trabalho tem como objetivo fazer uma explanação teórica e matemática que servirá de base ao estudo e compreensão do MIL e propor uma aplicação ao mesmo: o MIL acionado por inversor de freqüência e utilizado para obtenção de posicionamento com auxílio de simulação computacional de algumas malhas de controle para tal posicionamento. / Since the rotating machines had been idealized, the Linear Induction Motor (LIM) has been researched and, along the time, new technologies are being developed in order to improve it. Many academic works were accomplished in several research centers and universities around the world. In Brazil, the first ones to study it with scientific approach were Professors Morency Arouca and Délio Pereira Guerrini, in the early 70\'s. Even nowadays, works are seldom developed, and most of them are dedicated to simulation of the LIM or obtaining of parameters of specific LIM\'s. The present work has as objective to study the mathematical and theoretical modeling, which will be used as basis in order to study and understand the LIM and to propose an application: the LIM fed by Frequency Inverter, used in order to obtain positioning, with simulation of specific control systems.

Page generated in 0.0851 seconds