• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 20
  • 2
  • 1
  • Tagged with
  • 143
  • 143
  • 92
  • 58
  • 55
  • 44
  • 43
  • 36
  • 33
  • 29
  • 25
  • 25
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Dosimetria de filtros dinamicos aprimorados

SILVA, ROSIANE A. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:23Z (GMT). No. of bitstreams: 0 / O objetivo deste trabalho foi realizar a dosimetria de filtros dinâmicos aprimorados (“Enhanced Dynamic Wedge” – EDW). Isso foi feito com dois intuitos: 1) a avaliação da implementação clínica do filtro dinâmico aprimorado considerando-se suas vantagens e desvantagens; e 2) a comparação entre a eficiência e a melhor aplicabilidade de três sistemas dosimétricos diferentes em conjunto com o filtro dinâmico aprimorado. Os sistemas dosimétricos utilizados foram: o Sistema de Imagem de Feixe (“Beam Image System” – BIS2G), da Scanditronix-Wellhöfer, uma câmara de ionização cilíndrica de 0,6 cm3 do tipo Farmer, e um arranjo linear de câmaras de ionização múltiplas (“Ionization Chamber Linear Detector Array”) com 23 câmaras de ionização cilíndricas de 0,14 cm3, tipo Farmer. Com o Sistema de Imagem de Feixe – BIS2G foi possível obter curvas de fluência que permitiram analisar a simetria dos perfis de fluência, linearidade da dose, efeito da taxa de dose e efeito da gravidade, características diretamente ligadas à qualidade do funcionamento do filtro dinâmico aprimorado, além de ter sido possível também calcular o fator filtro para campos simétricos. Com a câmara de ionização mediu-se a porcentagem de dose em profundidade - PDP e calculou-se o fator filtro para campos simétricos e campos assimétricos (uma das vantagens do EDW). Com o arranjo linear de câmaras de ionização múltiplas foi possível obter curvas de isodose que permitiram a verificação da simetria e a comparação com os resultados obtidos com o BIS2G, além do cálculo do fator filtro para campos simétricos. O fator filtro calculado através de medidas tomadas com os três sistemas foi também comparado com resultados obtidos por dois formalismos, de Gibbons1 e de Klein et al 2, bem conhecidos da literatura e que serviram para a validação dos resultados e deste trabalho. Destas comparações verificou-se que os ângulos do filtro dinâmico aprimorado que apresentam maior diferença entre resultados obtidos e os formalismos foram os ângulos de 45º e de 60º em relação ao método de Klein et al que apresentaram diferenças de 2,1% em relação ao BIS2G, 1,9% em relação à câmara de ionização e 1,1% em relação ao arranjo linear de câmaras de ionização. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
82

Desenvolvimento e aplicacao de metodologia de feixes terapeuticos de raios x com sistema Tandem

SARTORIS, CARLA E. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:11Z (GMT). No. of bitstreams: 1 07166.pdf: 3329418 bytes, checksum: 88c4b97cfccfc432748bf428347c8e76 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
83

Implantação do novo protocolo de dosimetria da AIEA no LCI/IPEN/CNEN

SIQUEIRA, PATRICIA M. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:44Z (GMT). No. of bitstreams: 0 / A fim de implementar o novo código de prática da Agência Internacional de Energia Atômica (AIEA) no Brasil, o Laboratório de Calibração de Instrumentos (LCI/IPEN) está realizando calibrações em termos de kerma no ar e em termos de dose absorvida na água, em feixes de 60Co. As razões ND,w/NK obtidas são comparadas com valores da literatura, obtendo-se concordância satisfatória. As diferenças entre os valores das razões CK (ND,w/NK) obtidas no presente trabalho e os valores da literatura são devidas a vários fatores. Estes fatores podem ser as variações entre as câmaras, que devem ser objeto de diferenças nas incertezas estimadas pelos PSDLs, e as diferenças nos padrões utilizados por cada Instituto de Metrologia Nacional (NMI) ou Laboratório de Dosimetria. No entanto, se forem conhecidas as razões entre cada NMI e o BIPM, para os padrões de kerma no ar e de dose absorvida na água, é possível a normalização das razões CK medidas para as razões equivalentes ao BIPM. Todos os resultados de razões CK obtidos foram convertidos para as razões equivalentes ao BIPM para facilitar a comparação. Neste trabalho é discutida a utilização da razão CK como parâmetro de controle de qualidade na verificação de resultados das calibrações rotineiras. Para avaliação dos procedimentos de calibração adotados no LCI, foram realizados testes de estabilidade a longo prazo com as câmaras de ionização padrões. Além disso, foi criado um banco de dados para armazenamento dos dados de calibração, com o objetivo de melhorar a qualidade do procedimento de calibração. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
84

Aceite, comissionamento e controle de qualidade em radiocirurgia / Acceptance, commissioning and quality control in radiosurgery

TORETI, DALILA L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:27:10Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:19Z (GMT). No. of bitstreams: 0 / A Radiocirurgia Estereotática é a técnica de tratamento que usa feixes estreitos de radiação focalizados com grande exatidão em uma lesão pequena. A introdução dos colimadores micro multi-lâminas (mMLC) permite que essa técnica alcance um maior grau de conformação de dose na lesão alvo, possibilitando uma menor irradiação das estruturas críticas e dos tecidos normais. Este trabalho visa apresentar os resultados dos testes de aceite e do comissionamento de um acelerador linear Varian ® 6EX dedicado à Radiocirurgia, associado com o colimador multi-lâminas da BrainLab ® instalado no Hospital das Clínicas da Faculdade de Medicina da USP (HC-FMUSP) e estabelecer um Programa de Garantia de Qualidade que seja exequível para os serviços que pretendem implantar essa técnica especial. Os resultados dos testes de aceitação mostraram-se coerentes e satisfatórios com as especificações definidas pelo fabricante e os testes de comissionamento ficaram dentro das recomendações internacionais. Os testes e as medidas que compõem o processo de controle de qualidade devem ser específicos para cada unidade de tratamento, assim como a necessidade, a frequência e os níveis de tolerância. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
85

Elaboracao e implementacao de testes de controle de qualidade em equipamentos de angiografia por subtracao digital

LAMMOGLIA, PATRICIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:46:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:44Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foram elaborados e implementados testes de controle de qualidade em equipamentos de angiografia por subtração digital. Estes testes foram baseados em normas nacionais e internacionais e foram implementados em cinco equipamentos de três instituições diferentes. Estes testes avaliam os parâmetros de desempenho dos equipamentos e são utilizados para a determinação da taxa de kerma no ar na entrada da pele do paciente e do corpo clínico. Os testes foram realizados utilizando dispositivos, simuladores de pacientes e câmaras de ionização. Os testes convencionais e do sistema de subtração digital indicaram que os equipamentos avaliados encontravam-se em bom estado de desempenho. Os testes para verificação da taxa de kerma no ar indicaram que um dos equipamentos avaliados apresentou altas taxas de kerma no ar na entrada da pele do paciente em modo fluoroscopia. Este problema foi notificado, e as devidas providências foram imediatamente tomadas pela gerência do hospital. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:99/06803-9
86

Desenvolvimento de um sistema dosimetrico para feixes de eletrons de enegias altas

SOUZA, CLEBER N. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:34Z (GMT). No. of bitstreams: 1 05589.pdf: 5500511 bytes, checksum: e678ea0585ad825ea9f71a7ce347adb4 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
87

Projeto, construção e caracterização de câmaras de ionização para utilização como sistemas padrões em feixes de radiação X e gama / Project, construction and characterization of ionizing chambers for use as standard systems in X and gamma radiation beams

PERINI, ANA P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:00Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:34Z (GMT). No. of bitstreams: 1 19053.pdf: 423725 bytes, checksum: fd7cf0eca97172d6f66db487b29c2059 (MD5) / As câmaras de ionização apresentam várias vantagens em comparação com os demais dosímetros: facilidade de uso, dependência energética pequena e excelente precisão. Estas vantagens aliadas ao grande número de exames de radiodiagnóstico e tratamentos radioterápicos motivaram o desenvolvimento deste plano de doutorado. Neste projeto foram desenvolvidas e caracterizadas câmaras de ionização para aplicação em dosimetria de feixes de radiodiagnóstico e em terapia, com boa precisão e desempenho nos testes de caracterização dentro dos limites recomendados internacionalmente. Elas foram construídas de maneira simples com materiais nacionais de baixo custo, para que elas possam ser reproduzidas e aplicadas em laboratórios de calibração. Os projetos das câmaras de ionização desenvolvidas e caracterizadas neste projeto apresentam diferenças relacionadas ao material e configuração geométrica em comparação às câmaras de ionização comerciais disponíveis no mercado. Além do desenvolvimento de câmaras de ionização para serem utilizadas em feixes padrões de radiação X como padrões de trabalho, neste projeto também foram desenvolvidas e caracterizadas experimentalmente e por simulação de Monte Carlo duas câmaras de ionização cavitárias de grafite de placas paralelas, que foram caracterizadas como sistemas padrões de referência para determinação da taxa de kerma no ar de fontes de radiação gama. Comparando a taxa de kerma no ar determinada com o padrão de referência do Laboratório de Calibração do IPEN, uma câmara de ionização tipo Farmer, com os valores de taxa de kerma no ar obtidos com as câmaras de ionização de grafite, as máximas diferenças obtidas foram de apenas 1,7% e 1,2% para as câmaras de ionização de grafite G1 e G2, respectivamente. Além disso, estas câmaras de ionização apresentaram fatores de correção próximos de 1,000, que é o ideal para uma câmara de ionização ser caracterizada como um sistema de referência. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
88

Projeto de um laboratorio integrado de calibracao de instrumentos no IPEN / Project of an integrated calibration laboratory of instruments at IPEN

BARROS, GUSTAVO A.S.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:20Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:32Z (GMT). No. of bitstreams: 0 / O Laboratório de Calibração de Instrumentos do Instituto de Pesquisas Energéticas e Nucleares oferece serviços de calibração de detectores de radiação utilizados em radioproteção, radiodiagnóstico e radioterapia, para o IPEN e também para instalações externas, públicas e particulares. Uma parte de suas instalações estão localizadas no prédio principal, junto com outros laboratórios e salas de estudo, e uma outra parte num prédio isolado, semienterrado (Bunker). Para a otimização, a modernização e principalmente a segurança, os laboratórios situados no prédio principal precisam ser transferidos para um local isolado. Neste trabalho foi desenvolvido um projeto de um laboratório integrado, que será uma expansão do atual Laboratório de Calibração de Instrumentos do IPEN. Para isto, foram feitos levantamentos radiométricos no local escolhido e levantadas todas as necesidades da equipe quanto a espaço e disposição das salas. No projeto, os laboratórios com equipamentos de radiação X, e fontes radioativas alfa e beta ficaram isolados numa parte do prédio, e as blindagens das paredes foram determinadas, dependendo do uso de cada laboratório. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
89

Desenvolvimento de câmaras de ionização especiais para controle de qualidade em mamografia / Development of special ionization chambers for a quality control program in mammography

SILVA, JONAS O. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:17Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:04Z (GMT). No. of bitstreams: 0 / A mamografia é um método de diagnóstico por imagem que utiliza radiação X. No controle de qualidade dos mamógrafos, as câmaras de ionização são usadas para verificar se os parâmetros de exposição das pacientes estão corretos. Contudo, as câmaras de ionização comerciais para dosimetria em mamografia representam alto custo para clínicas de pequeno e médio porte que desejam ter esse equipamento ou para profissionais que trabalham com controle de qualidade. Assim, a característica inovadora deste trabalho foi desenvolver câmaras de ionização para este fim. Neste trabalho foram projetadas, construídas e caracterizadas câmaras de ionização para feixes de radiação X, no intervalo de energia de mamografia. As câmaras de ionização foram caracterizadas em feixes padronizados de radiação X no LCI/IPEN. Os testes principais de caracterização das câmaras de ionização foram: curva de saturação, linearidade da resposta, dependência energética e angular. Os testes de estabilidade da resposta das câmaras de ionização também foram realizados, apresentando resposta dentro de 2,0 % para estabilidade em longo prazo. Os resultados dos demais testes foram em conformidade com normas internacionais. Essas câmaras de ionização foram ainda submetidas a testes de controle de qualidade de mamógrafos quanto à linearidade das taxas de kerma no ar, à determinação das camadas semirredutoras e das doses glandulares médias. Para a linearidade da taxa de kerma, os valores obtidos foram abaixo dos 10 %, como estabelecido em norma. A dose glandular determinada com as câmaras desenvolvidas apresentaram valores comparáveis com os da câmara de referência testada, com variação prevista em recomendações internacionais. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
90

Estudo comparativo entre metodos de calibracao de aplicadores clinicos de radiacao beta / Comparative study among calibration methods of clinical applicators of beta radiation

ANTONIO, PATRICIA de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:14Z (GMT). No. of bitstreams: 0 / Os aplicadores clínicos de 90Sr+90Y são instrumentos utilizados em procedimentos de braquiterapia e devem ser calibrados periodicamente, de acordo com normas e recomendações internacionais. Neste trabalho, foram estudados quatro métodos de calibração de aplicadores dermatológicos e oftálmicos, comparando-se os resultados com os fornecidos pelos certificados de calibração dos fabricantes dos aplicadores. Os métodos envolveram o aplicador clínico padrão do Laboratório de Calibração de Instrumentos (LCI), calibrado pelo laboratório padrão primário americano do National Institute of Standards and Technology, como referência; um aplicador da Amersham, também pertencente ao LCI, como referência; uma mini-câmara de extrapolação desenvolvida no IPEN como padrão absoluto; e dosimetria termoluminescente. A mini-câmara de extrapolação e uma câmara de extrapolação comercial PTW foram estudadas com relação ao seu desempenho por meio de testes de controle de qualidade, como corrente de fuga, repetitividade e reprodutibilidade. A distribuição de dose em profundidade na água, estudo de grande importância na dosimetria de aplicadores clínicos, foi determinada utilizando-se a mini-câmara de extrapolação e dosímetros termoluminescentes. Os resultados obtidos foram considerados satisfatórios para os dois casos, quando comparados com os dados fornecidos pela norma IAEA (2002). Além disso, foi desenvolvido um sistema postal dosimétrico para a calibração de aplicadores clínicos por meio da técnica da termoluminescência, para ser enviado para clínicas e hospitais, sem a necessidade do transporte das fontes ao LCI do IPEN para calibração. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.1313 seconds