• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 20
  • 2
  • 1
  • Tagged with
  • 143
  • 143
  • 92
  • 58
  • 55
  • 44
  • 43
  • 36
  • 33
  • 29
  • 25
  • 25
  • 24
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
111

Estudo teórico experimental da resposta radiométrica de câmaras de ionização utilizadas em dosimetria em feixes de raios X para diagnóstico radiológico / Theoretical-experimental study of the radiometrical response of ionization chambers used in X ray beam dosimetry in diagnostic radiology

Rodrigo Sanchez Giarola 05 September 2014 (has links)
O Programa de Controle de Qualidade de sistemas geradores de raios X inclui a verificação periódica da constância dos feixes de raios X, para tanto é preciso que o físico especialista conheça as respostas dos instrumentos medidores de radiação. Neste trabalho foi analisado o comportamento das câmaras de ionização submetidas a feixes de radiação em Radiodiagnóstico nas energias de 50, 81, 90 e 102 kV. Inicialmente foram realizadas medidas experimentais com oito câmaras de ionização de quatro modelos- e, em seguida, foi simulado através do Método de Monte Carlo, com o código MCNP5, um sistema gerador de raios X e os quatro modelos de câmaras de ionização empregados na parte experimental. Com as simulações de arranjo padronizado foi calculado o valor de kerma no ar e foram comparadas, então, as respostas obtidas experimentalmente com os cálculos por simulação. As correlações obtidas entre os resultados permitiram o desenvolvimento de uma ferramenta que apresenta maiores informações para a compreensão dos equipamentos detectores utilizados, e que auxilia o especialista em física médica na análise da resposta dos detectores. / The Quality Control Program for X ray generator systems includes the periodic verification of the X rays beams constancy, therefore it is necessary that the medical physics specialist knows the measuring instruments physical response to radiation. In this work it was analyzed the behavior of ionization chambers subjected to radiation beams at diagnostic radiology energies of 50, 81, 90 and 102 kV. Initially it was performed experimental measurements with eight ionization chambers four models- and then it was simulated, by Monte Carlo Method, with the MCNP5 code an X ray generator system and the four ionization chambers models used in the experimental part. A patterned array was taken by the simulations and the air kerma value was calculated to the simulated system and then those values were compared to the experimental data. The correlations between the results allowed the development of a tool that enables a better understanding of the detectors and helps the physics specialist in the analysis of the detectors response.
112

Avaliação de dispositivos de proteção individual utilizados em radiologia diagnóstica

SOARES, FERNANDA C.S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:13Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
113

Intercomparação de câmaras de ionização em feixes padrões de raios X, níveis radioterapia, radiodiagnóstico e radioproteção

BESSA, ANA C.M. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:19Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
114

Medidas do primeiro coeficiente de Townsend de ionização no isobutano puro submetido a campos elétricos uniformes / Measurements of Townsend first ionization coefficient in pure isobutane under uniform electric fields

PETRI, ANNA R. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:54Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:30Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
115

Desenvolvimento e caracterização de câmaras de ionização cilíndricas como sistemas de referência para dosimetria de feixes de radiação de fótons / Development and characterization of cylindrical ionization chambers as dosimetric reference systems for photon radiation

NEVES, LUCIO P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:41:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:28Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:10/01070-4
116

Metodologia dosimetrica e sistema de referencia para radiacao x nivel diagnostico

POTIENS, MARIA da P.A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:51Z (GMT). No. of bitstreams: 1 06644.pdf: 6476949 bytes, checksum: 537fe5234ba74d48639417cebfe94231 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
117

Estabelecimento de um sistema padrão primário para raios X baixas com uma câmara de ionização de ar livre de energias / Establishment a primary standard system for low energy X-rays using a free air ionization chamber

SILVA, NATALIA F. da 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:43:46Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:43:46Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
118

Intercomparacao de colimadores de multiplas laminas para implementacao de terapia de feixes de intensidade modulada

VITERI, JUAN F.D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:51:09Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:37Z (GMT). No. of bitstreams: 0 / Neste trabalho é apresentada uma intercomparaçào das características dosimétricas entre três sistemas de colimadores multi-lâminas: Varian Millenium com 120 lâminas, mMLC m3 Brainlab e Varian Mark II ambos com 52 lâminas. A largura da projeção das lâminas no isocentro e na região central do campo é de 0,5 cm; 0,35 cm e 1,0 cm respectivamente. Foram comparadas características dosimétricas comuns aos três sistemas em modo estático e, no modo dinâmico, o trabalho limitou-se aos dois primeiros. Em modo dinâmico, foram realizados testes que avaliam o funcionamento através da irradiação em filme de figuras padrão, como a reprodutibilidade e estabilidade do MLC. Foi testada a linearidade das UM, sensibilidade â interrupção de tratamentos, a constância na velocidade das lâminas encontrando-se em todos os casos dentro do ±3%. Na linearidade da taxa de dose existem diferenças quando este parâmetro diminui. Encontrou-se que o desvio médio da dose é inversamente proporcional à abertura média dos campos dinâmicos. O fator de rendimento em modo dinâmico apresentou variações de até 1% quando o sistema suporte funcional se encontrava em posições laterais. Para os três sistemas de MLC, nos perfis para um mesmo tamanho de campo foi observada uma inclinação maior na região de penumbra para o mMLC; nos fatores de rendimento existem também pequenas diferenças de um sistema para outro. A abertura dosi métrica entre pares de lâminas foi determinado para o MLC 120, mMLC e MLC 52, os valores obtidos para 6 MV foram: (0,202 ± 0,054) cm; (0,157 ± 0,070) cm e (0,189 ± 0,081) cm respectivamente. A transmissão apresentou um comportamento crescente com a profundidade e o tamanho de campo para 6 MV nos três sistemas. Os valores médios determinados com câmara de ionização para 6 MV foram os seguintes: (1,630 ± 0,018)% para o MLC 120; (1,291 ± 0,029)% para o mMLC e (1,638 ± 0,010)% para o MLC 52. Quando testada com filme, a transmissão entre as lâminas e intralâminas apresentou dependência com a posição fora do eixo central tanto no MLC 120 quanto no mMLC. A porcentagem de espalhamento produzido pelo MLC, com relação a um campo aberto de referência de 6 MV foi: (0,297 ± 0,024)% para o MLC 120; (0,239 ± 0,052)% para o mMLC e (0,202 ± 0,028)% para o MLC 52. A penumbra (80-20%) em função do deslocamento fora do eixo não apresentou variações significativas nos três sistemas. Para todos os MLCs, a penumbra apresentou um comportamento crescente em função do tamanho de campo definido pelas lâminas. Em função da profundidade em 6 MV, a penumbra apresentou o menor valor para o mMLC em d max: 2,59 mm e o maior é 6,74 mm para o MLC Mark II a 10 cm de profundidade. A penumbra em função do ângulo que as lâminas formam com o seu eixo de movimento, para o ângulo de 10° no mMLC apresentou um valor 3,74 mm; já para os ângulos maiores, os maiores valores foram os obtidos para o Mark II. A série de testes descrita no presente trabalho permite estabelecer uma rotina no comissionamento de sistemas de MLC que pode ser aplicada nos serviços de Radioterapia que vão comissionar sistemas de MLC para IMRT em modo dinâmico. Os resultados descritos permitem caracterizar cada um dos sistemas de MLC estudados. Não é possível dizer que um sistema é melhor que outro, mas é possível, a partir da escolha de um deles, identificar as possíveis vantagens e desvantagens que cada um vai apresentar. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
119

Estabelecimento e controle de qualidade de feixes padroes de radiacao X para calibracao de instrumentos, nivel mamografia

GUERRA, ALINE B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:41Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:10Z (GMT). No. of bitstreams: 1 07150.pdf: 9130636 bytes, checksum: cb7e14964ddd9719ff5fe8392bed1d90 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
120

Desenvolvimento de camaras de ionizacao Tandem para utilizacao em programas de controle da qualidade em radioterapia e radiodiagnostico

COSTA, ALESSANDRO M. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:23Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:11Z (GMT). No. of bitstreams: 1 08715.pdf: 4323271 bytes, checksum: 6c93cac5d8cfc34b7d3a208547cb8f8d (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:98/14763-4

Page generated in 0.0989 seconds