• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 100
  • 32
  • 23
  • 15
  • 8
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 454
  • 454
  • 186
  • 183
  • 40
  • 38
  • 34
  • 32
  • 30
  • 30
  • 30
  • 29
  • 28
  • 27
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Avaliação morfológica e biomecânica dos efeitos da radiação gama em osso humano liofilizado ou congelado / Morphological and biomechanical evaluation of gamma radiation effects on lyophilized or frozen human bone

Santin, Stéfany Plumeri 04 December 2013 (has links)
Diversos pacientes são beneficiados com ossos armazenados em Bancos de Tecidos e utilizados em cirurgias reconstrutivas ortopédicas e em implantodologia como aloenxertos. No entanto, há uma intensa preocupação em garantir segurança na esterilidade do aloenxerto para proporcionar eficácia no transplante. Para minimizar possíveis contaminações utiliza-se a radiação ionizante como forma de esterilização final, desde que esta seja feita de maneira controlada, evitando possíveis modificações na matriz óssea. No presente trabalho, utilizamos as técnicas de colorimetria para avaliar modificações estéticas, Tomografia por Coerência Óptica, Tomografia por Coerência Óptica sensível à polarização, espectroscopia Raman e ensaios mecânicos de compressão para identificar as possíveis alterações na matriz óssea, ocasionadas pela forma de preservação, assim como, pelas diferentes doses de irradiação. Foram obtidas 8 amostras de fíbulas de 4 doadores, fracionadas de maneira a obter 48 amostras liofilizadas e 48 amostras congeladas. As amostras foram irradiadas com as doses de 15, 25 e 50 kGy comparando os resultados com o controle não irradiado. Observamos uma diminuição na intensidade das cores iniciais, mais relacionada com o processamento e preservação das amostras, e para as amostras irradiadas somente foi observado um aumento da coloração amarelada na dose de 50 kGy. A forma de preservação por liofilização ocasionou maiores modificações na estrutura terciária do colágeno dos ossos irradiados nas diferentes doses, principalmente nas doses acima de 25 kGy, porém estas modificações não foram suficientes para alterar a organização das fibras de colágeno. Quanto à resistência mecânica, verificou-se que as amostras liofilizadas foram menos resistentes que as congeladas e nas doses de 15 kGy e 25 kGy em ambas as formas de preservação ocorreu uma tendência a diminuir a resistência mecânica em relação ao controle. / Several patients are benefited with bones stored in Tissue Banks and used in orthopedic reconstructive surgery and implantodology as allografts. However, there is a strong concern to ensure safety in sterile allograft transplantation in order to provide efficacy. To minimize a probable contamination, ionizing radiation is used as a form of final sterilization, since the procedure is done in a controlled manner, avoiding possible changes in the bone matrix. In this dissertation, the techniques of colorimetry were used to evaluate aesthetic modifications; Optical Coherence Tomography, Optical Coherence Tomography sensitive to polarization, Raman spectroscopy and mechanical compression was carried out to identify possible changes in the bone matrix, caused by the preservation method, as well as the different irradiation doses. Eight fibulae from four donors were fractionated and from that forty-eight lyophilized samples and forty-eight frozen samples were obtained. The samples were irradiated with doses of 15, 25 and 50 kGy and the results were compared with the non-irradiated control. A decrease in the intensity of the initial colors was noticed and it was more related to the processing and preservation of the samples; for the irradiated samples, only an increase in the yellowness was observed, in the 50 kGy doses. The lyophilization preservation method caused major changes in the tertiary structure of the bone collagen irradiated at different doses, particularly at doses above 25 kGy, but these changes were not enough to change the organization of collagen fibers. Regarding the mechanical strength, were detected that lyophilized samples were less resistant than those which were frozen. With doses of 25 kGy and 15 kGy, in both forms of preservation, the mechanical strength tended to decrease, compared to the control. Therefore, it was observed that the aesthetic and structural changes caused by the different irradiation doses depend on the processing used in the Tissue Banks, besides the preservation method selected.
152

"Toxoplasma gondii vs radiação ionizante: Estudo da imunidade intestinal em camundongos C57Bl/6j experimentalmente vacinados com taquizoítos irradiados" / Toxoplasma gondii vs ionizing radiation: Intestinal immunity induced in C57bl/6j mice by irradiated tachyzoites

Galisteo Junior, Andrés Jimenez 20 April 2004 (has links)
Em nosso estudo pretendemos estudar a via oral para o desenvolvimento de vacina para toxoplasmose utilizando parasitas irradiados por Cobalto-60, como uma alternativa para a prevenção desta importane parasitose. Para tanto, avaliamos o desenvolvimento da imunidade sistêmica e intestinal e a resistência à infecção, em camundongos imunizados por esta via com taquizoítos irradiados a 255Gy, e desafiados com cistos da cepa ME-49. Camundongos isogênicos C57Bl/6j foram imunizados com 107 taquizoitos de T. gondii irradiados a 255Gy em diferentes esquemas e utilizando adjuvantes leite (anti-péptico) e hidróxido de alumínio (anti-ácido). As preparações de taquizoítos irradiados por via oral induziram produção de imunoglobulinas IgG e IgA no soro de camundongos, sendo predominante a subclasse de IgG2a, similar a infecção crônica, determinadas por ELISA. Seu uso com adjuvantes anti-pépticos ou anti-ácidos induziu produção de IgA fecal e menos significativamente de IgG fecal. Existem indícios de indução de tolerância em nível intestinal, com queda da produção de anticorpos e da proliferação celular antígeno dirigida, especialmente quando o leite foi utilizado como adjuvante, em ensaios de produção in vitro de anticorpos ou proliferação estimulada por antígenos de T.gondii, por esplenócitos e linfócitos intestinais. As preparações orais induziram proteção quantitativa ao desafio dos animais imunizados por cepa cistogênica, que foi semelhante a imunização parenteral, quando o hidróxido de alumínio foi usado como adjuvante. Todos estes dados mostram a possibilidade de desenvolvimento de uma vacina oral para toxoplasmose utilizando taquizoítos irradiados, com aplicação prática num futuro próximo para uso em campo, utilizando iscas atrativas para imunizar felinos domésticos e selvagens. / We study the oral route for the development of a vaccine for toxoplasmosis, using parasites irradiated with 60 Cobalt, as an alternative for vaccine development to this worldwide parasitic infection. We evaluated the development of immunity at serum or mucosal levels, and their efficiency in protect the mice against challenge with oral cysts of the ME-49 strain. C57Bl/6j isogenic mice were immunized by oral route with 107 255 Gy irradiated tachyzoites from RH strain, at several protocols using milk as anti-peptic adjuvant and alum hydroxide as antacid. The preparations of irradiated tachyzoites induced production of serum IgG and IgA in immunized mice, as determined by ELISA, with IgG2a as the dominant subclass, similar to chronic infection. Their use with adjuvant allowed the excretion of significant amounts of IgA in stools also IgG, despite a lesser extent. There are suggestion of tolerance induction at mucosal level, with lower antigen induced proliferation and lower in vitro antibody production by spleen and gut lymphocytes, with the latter doses, specially when milk was used as adjuvant. All oral preparations induced some quantitative protection against challenge, which was similar to the parenteral route only isolated alum hydroxide was used as adjuvant. All these data support the possibility of the development of an oral vaccine against toxoplasmosis, using irradiated tachyzoites, which would be possible tool in near future for use in field baits, for immunizing either domestic or wild felids.
153

Efeito da irradiação por feixe de elétrons sobre as propriedades físicas e químicas de uma resina de polipropileno. / Effect of electron beam irradiation by on the physical and chemical properties of a resin polypropylene.

Santos, Alessandra Fernandes 30 March 2011 (has links)
No presente trabalho modificou-se o polímero polipropileno por meio de radiação por feixes de elétrons com dose de 20, 40, 60, 100, 200 e 300kGy. Foram estudados os efeitos das doses de radiação nas propriedades físicas e químicas do polímero e a possível existência de uma correlação entre os resultados da indentação instrumentada e as demais propriedades físico-químicas do polímero, assim como ocorre com os metais. O polímero foi submetido aos ensaios de tração, indentação instrumentada, difração de raios-X (DRX), espectroscopia de elétrons na região do ultravioleta próximo e visível (UV VIS), espectroscopia vibracional no infravermelho com transformada de Fourier (FTIR), índice de fluidez, fração gel e análise térmica. Sobre as propriedades químicas do polímero observa-se que em doses de esterilização (até 20kGy) o mesmo não sofre oxidação radiolítica. A partir de doses superiores a 40kGy o polímero apresentou modificação permanente de cor (amarelecimento). Esta formação da cor mostrou ser ocasionada pela presença crescente do grupo cromóforo -C=O, fato este confirmado pelos resultados de espectroscopia UV-VIS. O resultado não pode ser comprovado no espectro de FTIR, porém observou-se que o método de preparação das amostras afetou o resultado deste ensaio lançando dúvidas sobre sua representatividade. A falha em identificar a presença crescente de grupos carbonila por FTIR, portanto, não invalida esta conclusão. Sobre as propriedades físicas do polímero comprovou-se com o ensaio de DRX que o aumento da dose de radiação não alterou a estrutura cristalina do polímero e não houve mudança significativa nos parâmetros de rede da célula monoclínica. Observou-se, entretanto, a diminuição da cristalinidade do polímero irradiado com doses de radiação até 60kGy. Para doses maiores observou-se novamente o aumento de fração cristalina, ou seja, a amostra sofreu recristalização induzida por irradiação. O polímero apresentou um aumento da resistência à degradação térmica com doses até 60kGy, permanecendo constante para doses maiores. Os resultados obtidos no ensaio de tração mostraram que o polímero irradiado com doses até 40kGy, não apresentaram alteração do limite de escoamento, porém para doses de radiação maiores houve decréscimo desta propriedade. Finalmente observou-se ensaio de indentação instrumentada não é sensível o suficiente para reproduzir as significativas alterações de propriedades mecânicas produzidas no polímero aqui estudado em função da irradiação por feixe de elétrons, porém observa-se uma queda acentuada do módulo de rigidez estimado no ensaio a partir do material irradiado com uma dose de 100kGy, que correlaciona com a recuperação da cristalinidade observada. / A polypropylene resin was modified in the present work by submitting standard tensile specimens to electron beam irradiation, with doses corresponding to 20, 40, 60, 100, 200 and 300kGy. The effect of this irradiation upon the polymer\'s chemical and physical properties was investigated, in particular seeking a possible correlation between these properties and instrumented indentation results, as it is common usage in the case of metals and alloys. The polymer was submitted to tensile, instrumented indentation, X-ray diffraction (DRX), electron spectroscopy (UV-VIS), vibrational infrared spectroscopy (FTIR), melt-flow index, gel fraction and thermal analysis tests. Concerning the chemical properties, it was observed that up to 20kGy dose there is no evidence of radiolytic oxidation in the polymer. Above 40kGy dose it was observed the irreversible yellowing of the samples, indicating the growing presence of chromophore groups (e.g. -C=O), which was confirmed by the UV-VIS results. The FTIR data could not confirm this hypothesis, but it was observed that the sample preparation method severely affected the FTIR spectra, casting doubt about its representativity. This failure of the FTIR data to identify the growing presence of carbonyl groups does not invalidate the previous results. Concerning the physical properties, X-ray diffraction showed that irradiation did not change the crystal structure of the polymer and no significant changes in lattice parameters could be identified either. The samples crystallinity, however, shows a remarkable reduction up to 60kGy dose. At the 100kGy sample, however, it was observed a recover of the crystallinity, which was attributed to radiation induced recrystallization. The thermal degradation resistance of the polymer enhanced up to 60kGy dose and remained approximately constant for higher doses. The yield strength of the samples kept approximately constant up to 60kGy dose, but decreased after that. Finally the instrumented indentation results where not sensible enough to detects the macroscopic mechanical properties, but the estimated Young\'s modulus shows a remarkable reduction for radiation doses equal or higher than 100kGy, which correlated well with the other chemical and physical properties.
154

Remoção da toxicidade do fármaco propranolol e de sua mistura com cloridrato de fluoxetina em solução aquosa empregando irradiação com feixe de elétrons / Removal of toxicity the pharmaceutical propranolol and your mixture with fluoxetine hydrochloride in aqueous solution using radiation with electron beam

Boiani, Nathalia Fonseca 25 November 2016 (has links)
A saúde do meio ambiente vem sendo comprometida devido ao descarte incorreto de produtos e seus subprodutos. Dentre os contaminantes emergentes encontram-se os fármacos, causadores de problemas ambientais por serem descartados no meio ambiente através dos efluentes. As técnicas convencionais de tratamento são insuficientes na remoção de diversos fármacos, por apresentarem resíduos resistentes e baixa biodegradabilidade. Sendo assim os processos oxidativos avançados vêm sendo estudados como alternativa para o tratamento de diferentes tipos de efluentes. O objetivo desse trabalho foi aplicar o processo de irradiação com feixe de elétrons para reduzir os efeitos tóxicos do propranolol, e de sua mistura com cloridrato de fluoxetina, em solução aquosa. Foram realizados ensaios ecotoxicológicos com o fármaco propranolol, e de sua mistura com o cloridrato de fluoxetina, utilizando como organismos-teste o microcrustáceo Daphnia similis, e a bactéria Vibrio fischeri. Observamos que o organismo D. similis mostrou-se mais sensível as amostras de fármacos quando comparado à bactéria V.fischeri. Após serem submetidas ao tratamento com radiação ionizante, todas as doses aplicadas para o propranolol e a mistura, mostraram significativa redução de toxicidade, tendo como organismo-teste D. similis. Para a bactéria V. fischeri apenas na dose de 5,0 kGy foi verificada a redução da toxicidade para o fármaco propranolol. Quanto à mistura dos fármacos, apenas as doses de 2,5 e 5,0 kGy apresentaram eficiência de remoção da toxicidade. A dose 5,0 kGy mostrou-se a melhor, apresentando redução de 79,94% para D. similis, e 15,64% para V. fischeri, quando expostas ao fármaco propranolol. Quanto à mistura, apresentou 81,59% e 26,93%, para D.similis e V.fischeri, respectivamente. / Environmental health has been damage due to incorrect disposal of products and by-products. Among emerging pollutants it is possible to account with several pharmaceuticals, causing those problems when disposed in the environment by effluents. Conventional processing techniques are insufficient in removal of the pharmaceuticals, for having resistant waste and low biodegradability. Thus the advanced oxidation processes have been studied as an alternative for the treatment of different types of effluents. The objective of this study was to apply the process of irradiation with electron beam in order to reduce the toxic effects of propranolol, and the mixture with fluoxetine hydrochloride in aqueous solution. Ecotoxicological tests conducted with propranolol, and the mixture with fluoxetine hydrochloride, for Daphnia similis microcrustacean, and the Vibrio fischeri bacterium. It was observed that D. similis was more sensitive to propranolol drug and to the mixture, when compared to bacterium V.fischeri. After being subjected to the treatment with ionizing radiation, all applied doses to the propranolol and the mixture, showed significant reduction of toxicity, for D. similis. Different were the results for V. fischeri, when only 5.0 kGy reduced toxicity to propranolol. The mixture of pharmaceuticals required 2.5 and 5.0 kGy for reducing toxicity. 5.0 kGy showed the best removal efficiency for toxicity: 79.94 % for D. similis and 15.64 % for V. fischeri, when exposed to propranolol. The mixture reduction eficacy were 81.59 % and 26.93 % for D.similis and V.fischeri, respectively.
155

Efeito da irradiação na toxicidade de fármacos em solução aquosa: cloridrato de fluoxetina, diclofenaco de sódio e mistura de ambos / Radiation effects onto toxicity of pharmaceuticals solution: hydrochloride fluoxetine, sodium diclofenac and their mixture

Tominaga, Flavio Kiyoshi 25 August 2016 (has links)
As evidências da contaminação das águas por resíduos de medicamentos e seus subprodutos levou esse grupo de resíduos a compor a lista de poluentes orgânicos emergentes, como consequência da expansão do uso de medicamentos, como o antidepressivo cloridrato de fluoxetina e o anti-inflamatório diclofenaco. Diversos Processos Oxidativos Avançados vêm sendo aplicados para a degradação destes compostos. Dentre eles, o processo de irradiação com feixe elétrons obteve bons resultados na remoção de toxicidade e degradação de fármacos. O presente estudo consistiu em aplicar radiação ionizante como uma possível tecnologia para degradar os fármacos em águas. A irradiação de solução aquosa contendo os fármacos foi aplicada usando acelerador de elétrons, cuja eficiência foi discutida mediante análises químicas (Cromatografia Líquida Ultra Rápida e Carbono Orgânico Total (COT)), ecotoxicológicas (ensaios de toxicidade com Vibrio fischeri e Daphnia similis) e biológicas (Ensaios Respirométricos). Os resultados de COT indicaram mineralização não significativa dos compostos, mesmo sendo observada degradação máxima de 99,9% para o diclofenaco e 55% para o cloridrato de fluoxetina na mistura (1:1) em 5.0 kGy. Foi observada toxicidade aguda dos fármacos, sendo mais acentuada para a fluoxetina, seguido do diclofenaco e, finalmente, da mistura para V. fischeri. Quando D. similis foram empregadas nessa avaliação, a ordem de toxicidade foi de fluoxetina, a mistura de ambos os medicamentos e do diclofenaco. Além disso, foi observada remoção de toxicidade nas amostras irradiadas em todas as doses aplicadas para a bactéria V. fischeri, com maior eficiência de remoção de toxicidade de 55%, em 5 kGy, na mistura dos dois fármacos. Para a D. similis, foi observada remoção significativa de toxicidade da mistura apenas na dose 2,5 kGy. Os ensaios respiroétricos não indicaram biodegradabilidade após o tratamento. / The evidence of water contamination by pharmaceuticals and byproducts residues took them to the list of wastewater emerging organic pollutants, as a result of expansion in drug usage. Fluoxetine hydrochloride antidepressant and diclofenac anti-inflammatory are good examplex. Several Advanced Oxidation Processes have been applied for degradation of these compounds. Among them, the electron beam irradiation process obtained good results in the removal of toxicity and degradation of pharmaceutical. The present study aimed to apply ionizing radiation as a possible technology to degrade the pharmaceutical in water. Irradiation of aqueous solution containing the pharmaceutical was applied using electron accelerator, whose efficiency was discussed through Chemical Analysis, COT, ecotoxicological (Toxicity Testing using Vibrio fischeri and Daphnia similis) and biological measurements (respirometric tests). The COT results indicated not significant mineralization of the compounds. It was observed maximum degradation of 99.9% for diclofenac and 55% for fluoxetine hydrochloride in a mixture solution (1:1) at 5.0 kGy. Regarding ecotoxicity, acute effects were more pronounced for fluoxetine, followed by diclofenac and finally the mixture, to Vibrio fischeri. When Daphnia similis were exposed fluoxetine was more toxic, followed by the mixture of both products and the third was diclofenac. Furthermore, radiation effects for removing toxicity was more effective with V. fischeri bacterium, all applied doses and > 55% removal of toxicity at 5 kGy (in the mixture). To D. similis, toxicity removal was effective when treated with 2.5 kGy ( mixture). No improvements in biodegradability was obtained by radiation ( respirometric tests).
156

Radioprotective effects of rooibos herbal tea on the developing central nervous system of wistar rats

Alrtemi, Milod M Ahmed January 2018 (has links)
Magister Scientiae - MSc / Background: Early postnatal radiation exposure from environmental, diagnostic or therapeutic sources is potentially deleterious to the developing nervous system resulting in oxidative stress, structural damage, altered neurochemistry, DNA damage, inflammatory stresses as well as correlating cognitive impairment during adult life. Numerous studies in literature have investigated the radioprotective effects of medicinal plants and beverages. However, only a few studies have focused on the radioprotective effects of rooibos, an indigenous South African herbal tea, well known for its many acclaimed health benefits. Aims: This study was done to investigate the diverse radioprotective potential of fermented Rooibos herbal tea (FRHT) consumed ad libitum by pregnant rats on the adult offspring rats exposed to a once-off 6 Gy dose of gamma irradiation on postnatal day 3. Methods: Twenty-four (24) adult female rats were equally divided into four groups (6 per group) as control (NS), radiation (X), tea (RT) and their combination. On PND 30, offspring rats were subjected to neurobehavioural assessment for open field and novel object recognition parameters and later sacrificed, the brain tissues removed and processed for histological, immunohistochemical and neurochemical analyses, using standard techniques. Results: Pre-treatment with FRHT showed overall protection against radiation-induced distortions in offspring rats by significantly improving exploratory activity, the frequency of central square entry, rearing episodes, cumulative freezing time and memory retention as indicated by a relatively higher recognition index. FRHT was also found to significantly improve the antioxidant defence mechanisms in the offspring rats by reversing lowered FRAP levels, increasing superoxide dismutase and catalase enzyme activities and reducing lipid peroxidation. Histological and immunohistochemical analyses showed that morphological alterations were generally attenuated in the RTX group and the high number of caspase-3 and Glial fibrillary acidic protein (GFAP)-positive cells was significantly reduced, indicating protective effects against apoptosis and gliosis. Conclusion: Taken together, our findings tend to suggest that the potential radioprotective effects of FRHT are multimodal, possibly executed through the anti-apoptotic, antioxidative, anti-gliosis and other mechanisms, as observed in this study, and this is often attributed to the high polyphenol content in Rooibos tea.
157

Comparação  das propriedades das superfícies da poliamida 6.6 tratada por plasma e por radiação ionizante / Comparison of the properties polyamide 6.6 surfaces treated by plasma and by ionizing radiation

Irineu, Rosa Maria da Silva 17 December 2010 (has links)
Este trabalho tem por objetivo a comparação das propriedades da superfície da poliamida 6.6 tratada por plasma e por radiação ionizante, assim como determinar qual a melhor técnica e condição para ativação da superfície, visando a adesão da mesma e borracha poliacrílica utilizada na fabricação de retentores automotivos. O tratamento da poliamida 6.6 por plasma foi realizado utilizando um equipamento Electronic DIENER Plasma Surface- Technology LFG40, com gás nitrogênio à pressão de 1,40 kg/cm2. As amostras de poliamida 6.6 também foram tratadas por radiação ionizante, à pressão atmosférica e em vácuo, utilizando um acelerador industrial de elétrons, Dynamitron JOB 188, com dose de radiação de 5, 10, 20, 40, 50, 100, 200, 300, 400 e 500kGy com taxa de dose de 11,22 kGy/s para todas as doses e taxa de 11,22 kGy/s e 22,38 kGy/s para a dose de 20kGy. Após os processos de modificação da superfície da poliamida 6.6, parte das amostras não tratadas, tratadas por plasma e por radiação ionizante foram incorporadas à borracha poliacrílica, e outra parte foi destinada a caracterização da superfície utilizando as técnicas de MEV/EDS, FT-IR, PIXE/RBS, AFM e ângulo de contato. As amostras não tratadas e as amostras irradiadas não aderiram à borracha poliacrílica. As amostras tratadas por plasma aderiram à borracha poliacrílica com eficiência e apresentaram diferenças de rugosidade, nas análises de MEV e AFM, e aumento no ângulo de contato quando comparado com as amostras não tratadas. As amostras irradiadas não apresentaram diferenças significativas de propriedades nas análises utilizadas neste trabalho, quando comparadas com as amostras não tratadas. A radiação ionizante não foi eficiente na modificação da superfície da poliamida 6.6 para aderência à borracha poliacrílica. / This study aims to compare the surface properties of polyamide 6.6 plasma treatment and ionizing radiation, as well as determine the best technique and condition of the surface activation, adhesion of the same order and polyacrylic rubber used in manufacturing of automotive retainers. Treatment of polyamide 6.6 plasma was performed using an equipment \"Electronic Diener - Plasma - Surface-Technology LFG40\" with nitrogen gas at a pressure of 1.40 kg/cm2. Samples of polyamide 6.6 were also treated with ionizing radiation, atmospheric pressure and in vacuum, using an industrial electron accelerator, Dynamitron JOB 188 with radiation dose of 5, 10, 20, 40, 50, 100, 200, 300, 400 and 500kGy with a dose rate of 11.22 kGy/s for all doses and rate of 11.22 kGy/s and 22.38 kGy/s for a dose of 20kGy. After the processes of surface modification of polyamide 6.6, part of the untreated samples, treated by plasma and by ionizing radiation were incorporated into the polyacrylic rubber, and another part was designed to characterize the surface using the techniques of SEM / EDS, FT- IR, PIXE / RBS, AFM and contact angle. Untreated samples and the irradiated samples did not join the polyacrylic rubber. The samples treated by plasma joined the polyacrylic rubber efficiently and showed differences in roughness in SEM and AFM, and an increase in contact angle when compared with untreated samples. The irradiated samples showed no significant differences in the analysis of properties used in this study when compared with untreated samples. Ionizing radiation was not effective in surface modification of polyamide 6.6 for adherence with polyacrylic rubber.
158

Efeitos da radiação em transistores 3D tensionados. / Effects of radiation on strained 3D transistors.

Fernando Ferrari Teixeira 30 May 2014 (has links)
Os efeitos causados pela radiação de raios X em transistores MOS com canal n e p, de porta tripla, com e sem tensionamento mecânico foram estudados teórica e experimentalmente. Após a irradiação de raios X, com doses totais acumuladas de 150Mrad e 3Mrad, em 12 dispositivos diferentes, foi constatada uma grande variação em algumas de suas características, como por exemplo um aumento de 40mV/dec na inclinação de limiar nos dispositivos mais largos, devido a criação de cargas positivas nos óxidos, tanto no enterrado quanto de porta. As cargas geradas no óxido enterrado apresentaram grande influência na condução de corrente pela segunda interface (silício/óxido enterrado), uma vez que o óxido enterrado é espesso (145nm), que por sua vez afetou significativamente diversos outros parâmetros. A formação de cargas positivas no óxido enterrado causou variações distintas no valor da tensão de limiar referente à segunda interface, em função do canal do transistor. No caso dos transistores MOS com canal n, foi observado um aumento na condução parasitária proveniente da segunda interface, enquanto que nos dispositivos MOS com canal p essa corrente foi minimizada devido aos efeitos da radiação, gerando uma melhora do desempenho destes dispositivos (é possível observar uma redução da inclinação de sublimiar de 60 a 80mV/dec no caso dos dispositivos mais largos). Entretanto, como o óxido de porta é mais fino que o óxido enterrado, não foram observadas grandes variações causadas pelas cargas formadas no mesmo. Quando comparada com a literatura, a dose total acumulada foi muito alta, então foi realizada uma nova rodada de radiação em que a distância entre a amostra e o feixe e a taxa de exposição foram alterados. Com isso, foi possível observar o mesmo efeito descrito anteriormente, porém com uma dose total acumulada cerca de 50 vezes menor. Em ambos os casos a exposição foi realizada sem a presença de polarização nos dispositivos, usada normalmente para reduzir a recombinação de portadores aumentando assim o efeito da radiação. Para realizar a polarização dos dispositivos durante a exposição de radiação, é preciso que os dispositivos estejam encapsulados, porém a etapa de encapsulamento poderia danificar os dispositivos utilizados. / The effects caused by the X-ray radiation in n and p channel triple gate transistors, with and without mechanical tensioning, were theoretically and experimentally studied. After X-ray irradiation on the devices, it was observed a large variation in some of their characteristics, such as an increase in the slope of 40mV/dec threshold in larger devices, due to the creation of positive charges in the oxides, both for the buried oxide as for the gate oxide. The charges generated in the buried oxide had great influence on the current conduction through the back interface (silicon / buried oxide), since the buried oxide is thicker (145nm), which in turn significantly affected many other parameters. The formation of positive charges in the buried oxide caused distinct variations in the threshold voltage on the second interface, depending on the channel type of the transistor. In the case of n-channel MOS transistors, it was observed an increase in parasitic conduction from the second interface, whereas for p-channel MOS devices the current was minimized - due to the effects of radiation - generating an improvement in performance of such devices (it is possible to observe a reduction of subthreshold slope of 60 to 80mV/dec in the case of larger devices).. However, as the gate oxide is thinner than the buried oxide, large variations caused by the generated charges were not observed. When compared to the literature, the total accumulated dose was very high, therefore, a new round of radiation were performed, in which the distance between the sample and beam, and the exposure rate were changed. Thus, it was possible to observe the same effect described above, but with a total accumulated dose about 50 times lower. In both cases, the bias was not used during the radiation exposure, normally used to reduce the recombination, thereby increasing the the radiation effect.
159

Comparação  das propriedades das superfícies da poliamida 6.6 tratada por plasma e por radiação ionizante / Comparison of the properties polyamide 6.6 surfaces treated by plasma and by ionizing radiation

Rosa Maria da Silva Irineu 17 December 2010 (has links)
Este trabalho tem por objetivo a comparação das propriedades da superfície da poliamida 6.6 tratada por plasma e por radiação ionizante, assim como determinar qual a melhor técnica e condição para ativação da superfície, visando a adesão da mesma e borracha poliacrílica utilizada na fabricação de retentores automotivos. O tratamento da poliamida 6.6 por plasma foi realizado utilizando um equipamento Electronic DIENER Plasma Surface- Technology LFG40, com gás nitrogênio à pressão de 1,40 kg/cm2. As amostras de poliamida 6.6 também foram tratadas por radiação ionizante, à pressão atmosférica e em vácuo, utilizando um acelerador industrial de elétrons, Dynamitron JOB 188, com dose de radiação de 5, 10, 20, 40, 50, 100, 200, 300, 400 e 500kGy com taxa de dose de 11,22 kGy/s para todas as doses e taxa de 11,22 kGy/s e 22,38 kGy/s para a dose de 20kGy. Após os processos de modificação da superfície da poliamida 6.6, parte das amostras não tratadas, tratadas por plasma e por radiação ionizante foram incorporadas à borracha poliacrílica, e outra parte foi destinada a caracterização da superfície utilizando as técnicas de MEV/EDS, FT-IR, PIXE/RBS, AFM e ângulo de contato. As amostras não tratadas e as amostras irradiadas não aderiram à borracha poliacrílica. As amostras tratadas por plasma aderiram à borracha poliacrílica com eficiência e apresentaram diferenças de rugosidade, nas análises de MEV e AFM, e aumento no ângulo de contato quando comparado com as amostras não tratadas. As amostras irradiadas não apresentaram diferenças significativas de propriedades nas análises utilizadas neste trabalho, quando comparadas com as amostras não tratadas. A radiação ionizante não foi eficiente na modificação da superfície da poliamida 6.6 para aderência à borracha poliacrílica. / This study aims to compare the surface properties of polyamide 6.6 plasma treatment and ionizing radiation, as well as determine the best technique and condition of the surface activation, adhesion of the same order and polyacrylic rubber used in manufacturing of automotive retainers. Treatment of polyamide 6.6 plasma was performed using an equipment \"Electronic Diener - Plasma - Surface-Technology LFG40\" with nitrogen gas at a pressure of 1.40 kg/cm2. Samples of polyamide 6.6 were also treated with ionizing radiation, atmospheric pressure and in vacuum, using an industrial electron accelerator, Dynamitron JOB 188 with radiation dose of 5, 10, 20, 40, 50, 100, 200, 300, 400 and 500kGy with a dose rate of 11.22 kGy/s for all doses and rate of 11.22 kGy/s and 22.38 kGy/s for a dose of 20kGy. After the processes of surface modification of polyamide 6.6, part of the untreated samples, treated by plasma and by ionizing radiation were incorporated into the polyacrylic rubber, and another part was designed to characterize the surface using the techniques of SEM / EDS, FT- IR, PIXE / RBS, AFM and contact angle. Untreated samples and the irradiated samples did not join the polyacrylic rubber. The samples treated by plasma joined the polyacrylic rubber efficiently and showed differences in roughness in SEM and AFM, and an increase in contact angle when compared with untreated samples. The irradiated samples showed no significant differences in the analysis of properties used in this study when compared with untreated samples. Ionizing radiation was not effective in surface modification of polyamide 6.6 for adherence with polyacrylic rubber.
160

Avaliação dos efeitos da radiação ionizante por feixe de elétrons na incorporação de fibras de piaçava (Attalea funifera Mart.) no copolímero de etileno e álcool vinílico (EVOH) / Evaluation of electron beam radiation effects in the incorporation of piassava fibers (Attalea funifera Mart.)on ethylene vinyl alcohol copolymer (EVOH)

Beatriz Ribeiro Nogueira 27 January 2012 (has links)
O objetivo deste trabalho é explorar a contribuição da radiação ionizante por feixe de elétrons na incorporação de fibras de piaçava (proveniente de resíduos de fábricas de vassouras) no copolímero de etileno e álcool vinílico (EVOH) para a obtenção de um material compósito EVOH-Piaçava para aplicações no segmento de embalagens. O interesse por esta fibra deve-se tanto a suas propriedades intrínsecas quanto a sua morfologia, além do fato de ser biodegradável. Os compósitos de EVOH reforçado com 5 % ou 10 %, em massa, de fibras de piaçava, em pó, com granulometria igual ou menor que 125 μm, não tratadas ou tratadas com 1 % de silano, foram obtidos por extrusão, utilizando-se uma extrusora dupla rosca. Foram confeccionados filmes dos materiais compósitos obtidos e da resina EVOH utilizando-se o processo de extrusão plana, para a viabilização dos ensaios de caracterização mecânica e de barreira a oxigênio dos materiais obtidos. As amostras de EVOH e dos compósitos foram submetidas à radiação ionizante em um acelerador de elétrons, às doses de radiação de 0 a 500 kGy. Os resultados das análises de MEV e difração de raios-X dos compósitos sugerem uma boa adesão fibra-matriz, o que pode ser confirmado também pela sua maior resistência à tração no ponto de ruptura quando comparada àquela do EVOH puro. Os resultados mostraram que a incorporação de fibras de piaçava pode promover melhor barreira ao oxigênio em comparação com o EVOH puro, em condições de umidade relativa alta. Observou-se que, após a irradiação, o filme de EVOH apresentou melhor barreira ao oxigênio em condição de umidade relativa alta quando comparado ao EVOH não irradiado nesta mesma condição, indicando o tratamento por radiação como efetivo para melhoria de barreira a oxigênio nas condições estudadas. / The aim of this work is to explore the contribution of ionizing radiation in the incorporation of piassava fibers (derived from wastes from broom factories) in the ethylene vinyl alcohol copolymer (EVOH), to obtain a composite material, \"EVOH-Piassava\", for packaging applications. The interest in this fiber is due to its inherent properties and morphology as well as being biodegradable. The EVOH composite reinforced with 5% or 10%, by weight of piassava fiber powder with a particle size equal to or less than 125 μm, untreated or treated with 1% silane, were obtained by extrusion, using a twin screw extruder. For carrying out the tensile tests and oxygen barrier of the materials obtained, films were produced from composite materials and EVOH resin was obtained using the process of flat extrusion. Samples of EVOH and the composites were irradiated using an electron accelerator, at doses from 0 to 500 kGy. The results of SEM analysis and X-ray diffraction of composites suggest a good fiber-matrix adhesion, which can be also confirmed by its higher tensile strength at break, compared to that of neat EVOH. The results showed that the incorporation of piassava fibers can promote better oxygen barrier compared to the neat EVOH, in conditions of high humidity. It was observed that, after irradiation, the EVOH film showed better oxygen barrier in high humidity condition, when compared to the non-irradiated EVOH under the same condition, indicating radiation as an effective treatment to improve oxygen barrier in the studied conditions.

Page generated in 0.2189 seconds