• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 100
  • 32
  • 23
  • 15
  • 8
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 454
  • 454
  • 186
  • 183
  • 40
  • 38
  • 34
  • 32
  • 30
  • 30
  • 30
  • 29
  • 28
  • 27
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
221

Estrutura eletrônica do polímero orgânico conjugado MEH-PPV em solução sob radiação ionizante /

Batagin Neto, Augusto. January 2009 (has links)
Orientador: Francisco Carlos Lavarda / Banca: Carlos Frederico de Oliveira Graeff / Banca: Paulo Monteiro Vieira Braga Barone / O Programa de Pós-Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra as atividades de pesquisa em materiais de diversos campi da Unesp / Resumo: Os polímeros orgânicos conjugados têm sido amplamente utilizados em diversos campos tecnológicos devido às suas características semicondutoras e ópticas. Recentemente foi relatada a possibilidade de sua utilização na área de dosimetria. O polímero MEH-PPV, quando diluído em solventes que contenham halogênios, tem apresentado características bastante promissoras nesta área, contudo não há ainda uma completa compreensão dos mecanismos envolvidos. No presente trabalho realizou-se o estudo conformacional e da estrutura eletrônica do polímero MEH-PPV em clorofórmio e as possíveis alterações provenientes da irradiação desta solução com radiações ionizantes. Métodos de modelagem de materiais foram utilizados a fim de simular o sistema. Resultados experimentais sugerem que os efeitos observados são oriundos da interação do solvente com a cadeia polimérica. A fim de investigar tal possibilidade, uma análise dos prováveis sítios de maior reatividade sobre o polímero foi realizada, apontando um mecanismo de incorporação de radicais sobre a cadeia principal. / Abstract: Organic conducting polymers have been employed in several technological fields due to its semiconducting and optical properties. Recently, several reports points to applications in radiation dosimetry. When diluted in halogen-containing solvents, the polymer MEH-PPV shows interesting properties after gamma irradiation. Despite the promising application, still is lacking a complete understanding of the underlying phenomena. In the present work, we studied the geometry conformation and electronic structure of MEH-PPV in the presence of chloroform employing molecular modeling techniques to simulate the system. Several possibilities for polymer modification under gamma radiation were investigated, following suggestion from experimental results. Finally, a model for the color modifications of the solution is present. / Mestre
222

Exposição à radiação ionizante dos profissionais de saúde em hemodinâmica: o enfoque da enfermagem / Exposure of health professionals to ionizing radiation at hemodynamic: the nursing's vision

Katia Maria dos Santos Calegaro 18 December 2007 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / As radiações ionizantes têm sido cada vez mais usadas na medicina contemporânea, inserida em contextos diagnósticos e terapêuticos. O objeto deste estudo foi, portanto, a exposição à radiação ionizante relacionada ao processo de trabalho dos profissionais de saúde em hemodinâmica e seus objetivos foram conhecer o perfil dos trabalhadores de saúde que atuam no setor de hemodinâmica, levantar os problemas de saúde provocados ou agravados pelo trabalho a partir da ótica do profissional, conhecer as doses ocupacionais dos trabalhadores, correlacionando os dados encontrados à luz da legislação específica vigente. Tratou-se de um estudo exploratório e descritivo com abordagem quanti-qualitativa que teve como instrumentos de coleta de dados: a observação sistemática do local de estudo, lê-se, o setor de hemodinâmica de um hospital universitário localizado na cidade do Rio de Janeiro; a aplicação de um questionário com 35 perguntas abertas e fechadas aos sujeitos do estudo, lê-se, os profissionais de saúde médicos, enfermeiros, técnicos de enfermagem e técnicos de radiologia que atuavam no setor de hemodinâmica; e a busca documental pelas doses ocupacionais retrospectivas dos trabalhadores. Como resultados, identificou-se uma população com média de 39 anos, com experiência profissional média, em saúde e hemodinâmica, de 10 anos, que trabalham em mais de uma instituição de saúde expostos à radiação ionizante. Foram discutidas questões relativas à saúde, segurança, formação e prática profissional dos sujeitos à luz das legislações que versam sobre o uso de radiações ionizantes. Concluiu-se a necessidade de adaptações e mudanças em diversas esferas / setores objetivando a otimização da radioproteção, da saúde dos trabalhadores e da prática em hemodinâmica. / Ionizing radiations have been used in the contemporary medicine, inserted in disgnostic and therapeutical contexts. Therefore, the object of this study was the relation among ionizing radiation exposition and the work process of the health professionals at hemodynamic; the objectives were: know the profile of the professionals working at hemodynamic unit, identify health problems caused or aggravated by work on the workers agreement, know the occupational dosis of this professionals and correlate data with the specific current law. This is a descriptive study, quanti-qualitative that had like data collection instruments: a systematic observation of an hemodynamic unit located in an university hospital in Rio de Janeiro; application of a questionnaire with 35 open and closed questions to population healths professionals: physicians, nurses, radiology technicians and nursing technicians - that works at hemodynamics, and a documentary search about their last occupational dosis. The results of this study shows a population with average age of 39 years, with a lot of professional experience, in health and hemodynamic (10 years in average), that work at more than one health institution exposed to ionizing radiation. Questions about health, security, graduation and professional practice had been analyzed and argued based in the specific legislation. The conclusions are a necessity of adaptations and changes in diverse sectors objectifying the optimization of radioprotection, workers health and the practice at hemodynamics units.
223

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução

Fernandes, David Moreira [UNESP] 30 March 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-03-30Bitstream added on 2014-06-13T20:40:11Z : No. of bitstreams: 1 fernandes_dm_me_bauru.pdf: 957024 bytes, checksum: 166e807e8c28852f41e7733849398194 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho teve como objetivo estudar as características dosimétricas do polímero poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)] (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... / This work aimed to study the dosimetric characteristics of the polymer of the polymerpoly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)] (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below)
224

Hrozba teroristického radiačního útoku / The threat of a terrorist radiation attack

RAŠÍNOVÁ, Libuše January 2007 (has links)
The goals of this thesis are as follows: Firstly, I seek to assess the risk of a terrorist radiation attack. I also characterize the effects that the ionizing radiation has on the human being and outline a scenario of a possible radiation attack. Secondly, I evaluate what awareness of the civil defence exists among the students in the final year of the compulsory school attendance. Thirdly, I propose some measures to improve the situation.
225

MEMS Harsh Environment Sensors for Earth and Space Exploration

January 2013 (has links)
abstract: Harsh environments have conditions that make collecting scientific data difficult with existing commercial-off-the-shelf technology. Micro Electro Mechanical Systems (MEMS) technology is ideally suited for harsh environment characterization and operation due to the wide range of materials available and an incredible array of different sensing techniques while providing small device size, low power consumption, and robustness. There were two main objectives of the research conducted. The first objective was to design, fabricate, and test novel sensors that measure the amount of exposure to ionizing radiation for a wide range of applications including characterization of harsh environments. Two types of MEMS ionizing radiation dosimeters were developed. The first sensor was a passive radiation-sensitive capacitor-antenna design. The antenna's emitted frequency of peak-intensity changed as exposure time to radiation increased. The second sensor was a film bulk acoustic-wave resonator, whose resonant frequency decreased with increasing ionizing radiation exposure time. The second objective was to develop MEMS sensor systems that could be deployed to gather scientific data and to use that data to address the following research question: do temperature and/or conductivity predict the appearance of photosynthetic organisms in hot springs. To this end, temperature and electrical conductivity sensor arrays were designed and fabricated based on mature MEMS technology. Electronic circuits and the software interface to the electronics were developed for field data collection. The sensor arrays utilized in the hot springs yielded results that support the hypothesis that temperature plays a key role in determining where the photosynthetic organisms occur. Additionally, a cold-film fluidic flow sensor was developed, which is suitable for near-boiling temperature measurement. Future research should focus on (1) developing a MEMS pH sensor array with integrated temperature, conductivity, and flow sensors to provide multi-dimensional data for scientific study and (2) finding solutions to biofouling and self-calibration, which affects sensor performance over long-term deployment. / Dissertation/Thesis / Ph.D. Engineering 2013
226

Avaliação dos efeitos da radiação ionizante e do Resveratrol na cultura de células tumorais de pulmão / Evaluation of ionizing radiation and resveratrol effects in lung cancer cell culture

Carolina dos Santos Moreno 20 May 2016 (has links)
O carcinoma mucoepidermóide de pulmão, um tipo histológico que deriva das glândulas mucosas traqueobrônquicas, manifesta-se com sintomas obstrutivos e tende a comprometer a traqueia. Com finalidade curativa ou paliativa da doença, atualmente há uma forte tendência na oncologia em desenvolver estratégias terapêuticas que visam à administração de compostos com elevado potencial de otimizar o efeito do tratamento com a radiação ionizante, de modo a aumentar a morte de células tumorais e preservar íntegras as células dos tecidos sadios adjacentes. A intensa busca por tais estratégias evidenciou resultados promissores apresentados pelo composto denominado Resveratrol (3,4,5-trihidroxiestilbeno), tornando-o amplamente divulgado e alvo de intensas pesquisas. O principal objetivo do presente estudo foi determinar o efeito do resveratrol em cultura celular de carcinoma mucoepidermóide de pulmão exposta a diferentes doses de radiação ionizante. Para tal, os estudos de citotoxicidade utilizando o método de incorporação do vermelho neutro, e da determinação da dose letal 50 % (DL50) da radiação ionizante, foram realizados em cultura de células da linhagem NCI-H292 [H292] (ATCC® CRL-1848TM), CCIAL069. Com base nos resultados do IC50% (401,5 μM) e da DL50 (693 Gy) foram realizados o teste in vitro do micronúcleo e os ensaios para avaliar o efeito do resveratrol no ciclo celular, reparo da lesão no DNA e processo de lesão radioinduzida, necrose e apoptose celular. Os resultados evidenciaram que o resveratrol na concentração de 30 μM apresenta uma importante capacidade em promover danos às células NCI-H292 após 24 h da irradiação. / Mucoepidermoid lung carcinoma is a histological type that derives from the tracheobronchial mucous glands. It is manifested by trachea symptoms. Curative or palliative purpose for the disease, nowadays presents a strong oncology tendency to develop therapeutic strategies aimed at the administration of high potential compounds to improve the ionizing radiation treatments, so as to increase the radiation effects on tumor cells while minimizing these effects to surrounding normal tissues. The intensive search for such strategies showed promising results by the compound called Resveratrol, making it widely available and subject of many studies. The main of this study was to determine in vitro resveratrol effect in mucoepidermoid lung carcinoma cells NCI-H292 [H292] (ATCC® CRL-1848TM), CCIAL069, exposed to ionizing radiation doses. For this purpose, there were performed in vitro cytotoxicity studies by neutral red uptake assay, as well as the lethal dose 50 % (LD50) of ionizing radiation. On the basis of the IC50% (401.5 μM) and LD50 (693 Gy) results, there were performed in vitro micronucleus test and other tests in order to evaluate the cell cycle, repair and injury processes, cellular apoptosis and necrosis inductions. The results showed that resveratrol in 30 μM concentrations showed an important capability to injury NCI-H292 cells after 24 h of irradiation.
227

Fabricação e caracterização de filmes finos de brometo de tálio (TIBr) / Fabrication and characterization of thallium bromide (TlBr) thin films

Natália Destefano 31 July 2009 (has links)
Por ser um semicondutor de elevado número atômico, elevada densidade de massa e largo gap de energia, o brometo de tálio (TlBr) é um material promissor para a detecção da radiação à temperatura ambiente. Entretanto, existem poucos trabalhos relacionados ao estudo deste material sob forma de filme fino policristalino para produção em grandes áreas como desejado para aplicações médicas. Neste trabalho, as técnicas de spray pyrolysis e evaporação térmica foram avaliadas como métodos alternativos para a deposição de filmes de TlBr policristalinos. Ambas as técnicas apresentam relativo baixo custo e podem facilmente ser expandidas para grandes áreas. O objetivos deste trabalho é o estudo da influência das principais condições de crescimento nas propriedades (estruturais, ópticas e elétricas) finais dos filmes de TlBr. Para os filmes produzidos por spray pyrolysis água mili-Q foi utilizada como solvente. A solução (0,10 g de TlBr dissolvidos em 100 g de água) foi agitada à temperatura de 70ºC. Cada deposição foi realizado mantendo os substratos (1cm x 1cm) à temperatura de 100ºC, com um fluxo de nitrogênio (N2) de 8 1/min e um fluxo de solução de aproximadamente 1/90 (ml/s). A distância bico de spray-substrato utilizada foi de 19 cm. Os filmes de TlBr evaporados foram crescidos pela evaporação térmica do material a partir de um cadinho de tungstênio. Um sistema de aquecimento dos substratos foi implantado e permitiu a variação da temperatura destes durante a deposição desde a temperatura ambiente até 200ºC. A separação substrato-superfície de evaporação, h, e o número de deposições por filme, n, também foram variados no intervalo de 3 a 9 cm e 1 a 4, respectivamente. A estrutura dos filmes foi investigada por Difração de Raio-x, a morfologia por Microscopia Eletrônica de Verredura e a composição através da Espectroscopia de Dispersão de Energia (EDS). Experimentos ópticos de transmitância em função do comprimento de ondas foram realizados para estimar o gap ótico dos filmes.As resistividades foram medidas a partir de experimentos de corrente em função da voltagem aplicada fluorescente (20 watts). Por fim, algumas amostras selecionadas foram expostas aos raios-X na faixa de diagnóstico mamográfico. As melhores propriedades foram obtidas para os filmes crescidos por evaporação térmica. A maior compactação e o maior gap óptico foram encontrados para os filmes produzidos a partir de h= 9 cm, os quais garantiram a maior sensibilidade para estes filmes quando expostos aos raios-X. Para os filmes produzidos pela deposição sequencial de várias camadas, a estrutura colunar dos filmes foi mantida para camadas superiores e resultados semelhantes para todas as amostras foram obtidos em relação ao gap óptico e à resistividade elétrica. Além disso, a sensibilidade a partir da utilização de raio-X na faixa mamográfica foi quadruplicada para o filme mais espesso. O aumento da temperatura do substrato resultou na maior compactação e homogeneidade no recobrimento do substrato. Entretanto, uma perda significativa de material durante a evaporação determinou filmes menos espessos em relação aos depósitos à temperatura ambiente. Variações cristalográficas e morfológicas foram obtidas entre os filmes depositados a diferentes temperaturas. Maiores valores gap foram obtidos para 150 e 200ºC. A caracterização elétrica dos filmes depositados a diferentes temperaturas foi limitada, neste trabalho, pela baixa pureza do pó utilizado para produção destes filmes. / Due to its high atomic number, high mass density and intrinsic band gap, thallium bromide (TlBr) is a promising semiconductor for room temperature operation for ionizing radiation detection. However, there are few works related to the study of this material in the polycrystalline thin film form for production in large areas (~ 40 x 40 cm2 ), as desired by medical applications. In this work, spray pyrolysis and thermal evaporation were used as alternative methods for the deposition of polycrystalline TlBr films. Both techniques present relative low cost and can be expanded for large areas. The aim of this work is to investigate the influence of the main growth conditions on the final structural, optical and electrical TlBr films properties. Films produced by spray pyrolysis used mili-Q water as solvent. The solution (0,10g of TlBr dissolved in 100g of water) was stirred at 70o C. Each deposition was performed maintaining the substrates (1cm2 ) at 100o C, the nitrogen rate at 8l/min and the solution flow at 1/90 ml/s approximately. The nozzle-spray to substrate distance was 19 cm. Evaporated TlBr films were grown by resistive thermal evaporation of purified material from a tungsten crucible. The substrate temperature was evaluated from room temperature to 200°C. The separation between evaporation source and substrates, h, and the number of depositions, n, were also varied from 3 cm up to 9 cm and from 1 up to 4, respectively. The structure of the crystals was investigated by X-ray Diffraction, the morphology by Scanning Electron Microscopy and the composition by Energy Dispersive X-Ray Spectroscopy. Optical experiments of absorbance as a function of wavelength were performed to estimate the optical gap of the TlBr films. Electrical resistivities were measured using current versus voltage experiments. The dark current was compared to the current under illumination with a fluorescent lamp (20 watts). Finally, some selected samples were exposed to X-ray in the range of mammography diagnosis. The best properties were obtained for films produced by resistive thermal evaporation. This technique allowed the production of films with thickness of approximately 28 µm, for a unique deposition of 12 minutes. However, bromine has lower vapor pressure than the thallium, what leads to a Br loss of about 10% in the composition of evaporated films. The smallest distribution of cracks and the largest optical gap were obtained for films produced at the lowest deposition rates. This leads also to a higher increase of the ratio between current under irradiation and in the dark, when the films were exposed to X-rays. For films produced at room temperature using sequential depositions, the columnar structure was kept for the superior layers and similar results for all samples were obtained in relation to optical gap and electrical resistivity. Moreover, for the thicker film, an increase of a factor 4 was observed for the ratio between current under irradiation using X-rays in the mammography range in relation to the dark. The higher substrate temperature leads to significant material loss during the evaporation and determined less thick films in relation to the ones deposited at room temperature. Structural and morphological variations were verified for films deposited at different temperatures. Larger gap values were found for 150 and 200ºC. For the electrical characterization of the films deposited at different temperatures an original powder with higher purity would be necessary. Moreover, due to the significant difference between bromine and thallium vapor pressures, better results would probably be obtained by a change to the hot-wall evaporation technique.
228

Efeitos da irradiação nas propriedades físico-químicas do feijão carioca / Effects of irradiation on the physicochemical properties of carioca beans

Dâmaris Carvalho Lima 08 July 2016 (has links)
O feijão é um importante alimento na dieta alimentar do brasileiro. A cada colheita ocorrem perdas dos grãos de feijão devido ao ataque de insetos e roedores. Uma das maneiras de se preservar os grãos de feijão, mantendo suas características nutricionais, é o uso da radiação gama. O objetivo do trabalho é avaliar os efeitos de diferentes doses da radiação gama nas propriedades físico-químicas do feijão carioca submetido à cocção e que sofreu ou não o processo de maceração. Partes dos feijões cariocas crus foram utilizadas como controle e outra parte foram submetidos à radiação ionizante com doses de 1, 5 e 10 kGy. Após a irradiação uma parcela das amostras (controle e irradiadas) passou pela maceração e outra não, em seguida, todos os feijões foram cozidos. As amostras cozidas foram liofilizadas, moídas e depois acondicionas em potes e armazenadas a temperaturas de -23ºC. As análises de composição centesimal, determinação da digestibilidade proteica, teores de tanino condensado e ácido fítico foram feitas utilizando as amostras moídas. Utilizando grãos inteiros, foram feitas análises de capacidade expansão e hidratação, tempo de cocção e cor instrumental. A irradiação não alterou a composição centesimal das amostras maceradas e sem macerar. Os teores de taninos condensados não reduziram conforme o aumento das doses. As concentrações de ácido fítico foram reduzidas nas doses de 5 e 10 kGy, para amostras maceradas, enquanto que para os feijões sem macerar, a irradiação gama não influenciou nos teores de fitatos. Ocorreu diminuição da digestibilidade proteica, nas amostras maceradas, a partir dose de 1 kGy, e as demais doses a redução não foi significativa. Já para os feijões sem macerar, houve aumento da digestibilidade, na dose de 10 kGy. Conforme o aumento das doses foi observado redução nos tempos de cocção dos feijões macerados e sem macerar. Na dose de 10 kGy, a capacidade de expansão do feijão aumentou. A coloração das amostras não modificou significativamente conforme o aumento das doses. Desta forma conclui-se que a radiação ionizante não influencia na composição centesimal e nos teores de taninos. A irradiação influenciou nos teores de ácido fítico em altas doses aplicadas, mas somente nas amostras maceradas, além de atenuar a digestibilidade proteica de feijões macerados. Reduz os tempos de cocção. Eleva a capacidade de expansão do feijão na dose de 10 kGy, porém não altera a coloração do feijão, conforme o aumento das doses / The common bean is an important component in the diet of the average Brazilian person. Each harvest of beans, losses occur due to attacks of insects and rodents. One of the ways to preserve the beans, and at the same time keep its nutritional characteristics, is the use of gamma radiation. This study aimed to evaluate the effects of different doses of gamma radiation on the physical and chemical properties of the carioca variety of common beans subject to cooking of soaked and unsoaked beans. Portions of raw beans were used as control and the other was subject to ionizing radiation at doses of 1, 5 and 10 kGy. Following irradiation, a portion of the samples (control and irradiated) were soaked and the other was not, then all beans were cooked. The cooked samples were lyophilized, milled and then accommodated in pots and stored at -23ºC temperatures. The analysis of chemical composition, determination of protein digestibility, condensed tannin and phytic acid content were performed using the milled samples. Using whole grains, were performed analysis of expansion capability and hydration, cooking time and instrumental color. Irradiation did not alter the chemical composition of soaked and unsoaked samples. The condensed tannin levels did not reduce according to increased doses. The phytic acid concentrations were reduced at the doses of 5 and 10 kGy for soaked samples, whereas for the not soaked beans, gamma irradiation did not influence the phytate content. The protein digestibility decreased on soaked samples, at doses of 1 kGy and in the other doses, the reduction was not significant. As for not soaked beans, increases in digestibility were observed at dose of 10 kGy. As the doses increased, reduction in cooking time on soaked and unsoaked beans was noted. At a dose of 10 kGy, the bean expansion capability increased. The samples\' color did not change significantly, as the doses increased. Therefore, it is concluded that ionizing radiation has no effect on the chemical composition and tannin content. Irradiation influenced the phytates when applied in higher doses, but only in soaked samples, as well as mitigate protein digestibility on soaked beans. It reduces cooking time, raises bean expansion capability at a 10 kGy dose, but it does not change the bean color as doses increase
229

AvaliaÃÃo MutagÃnica em CirurgiÃes Dentistas Expostos Ocupacionalmente à RadiaÃÃo Ionizante / Evaluation mutagenic dentists occupationally exposed to ionizing radiation.

Maria do Amparo da Silva Bida Mesquita 21 December 2011 (has links)
nÃo hà / Os raios X sÃo bastante utilizados nas prÃticas mÃdicas e odontolÃgicas, mas sÃo agentes mutagÃnicos potentes capazes de induzir Ãs mutaÃÃes e aberraÃÃes cromossÃmicas. Este trabalho teve por objetivo avaliar os efeitos da radiaÃÃo ionizante induzida por raios X em cÃlulas esfoliadas da mucosa bucal de cirurgiÃes dentistas exposto ocupacionalmente, atravÃs da aplicaÃÃo do teste de micronÃcleos, para evidenciar nÃmero e freqÃÃncia de micronÃcleo, alÃm de outras anormalidades nucleares, como cÃlulas binucleadas, cariorrexe (fragmentaÃÃo nuclear) e cariÃlise (dissoluÃÃo nuclear). A idade da populaÃÃo estudada foi de 32 a 65 anos, representado por cirurgiÃes dentistas sendo 95% de brancos e 5% negros, enquanto que a nÃo exposta foi de 30% branco e 25% negros. Em relaÃÃo à exposiÃÃo a agentes quÃmicos e fÃsicos, os resultados mostraram que 100% dos cirurgiÃes dentistas se expÃem aos dois tipos de agentes. Nos Ãltimos dez anos, 65% dos expostos e 45% dos nÃo expostos realizaram raio X com fins terapÃuticos. Quanto ao tempo de trabalho, o grupo dos sujeitos com exposiÃÃo à radiaÃÃo ionizante supera o grupo dos nÃo expostos, 19,40  8,74 vs correspondendo de 11 a 32 anos nos expoxtos e 6,55  7,09 vs correspondendo de 11 a 25 anos nos nÃo expostos. Quanto ao uso de proteÃÃo, 100% de ambos os grupos nÃo utilizam proteÃÃo. A avaliaÃÃo mutagÃnica foi evidenciada pelo nÃmero de micronÃcleo em cÃlulas esfoliadas do epitÃlio bucal, 5,85  3,58 vs nos expostos e de 1,00  0,85 nos nÃo expostos, como tambÃm pela freqÃÃncia de micronÃcleo, sendo 0,41 0,27MN nos expostos e de 0,02  0,04 MN nos nÃo expostos, com significÃncia de p< 0,001 nos expostos em relaÃÃo aos nÃo expostos. As anormalidades nucleares como cariorrexe (39,49  16, 29 vs 16, 03  8,61), cariÃlise (6,92  5,87 x 1,11  0,99) e cÃlulas binucleadas(12,45  8,43 x 0,76  0,23), em relaÃÃo aos nÃo expostos, evidenciam apoptose, necrose e citotocixidade e foram estatisticamente significante p<0,01. NÃo foi encontrada correlaÃÃo positiva entre hÃbitos de vida, doenÃas genÃticas e a presenÃa de micronÃcleos ou anormalidades nucleares. Assim, os resultados deste trabalho indicam que as radiaÃÃes odontolÃgicas induzem danos ao material genÃtico de cÃlulas esfoliadas da mucosa bucal, ocasionando tambÃm aumento de apoptose, indicando que o uso deste procedimento deve ser requisitado somente quando necessÃrio. Este trabalho demonstra tambÃm a importÃncia de se avaliar as outras anormalidades nucleares e nÃo apenas os micronÃcleos como indicadores de danos ao DNA. A preocupaÃÃo com esses efeitos à pertinente, principalmente aos expostos ocupacionalmente, pois alÃm de estabelecer um prognÃstico da incidÃncia do desenvolvimento de cÃncer, a monitoraÃÃo das exposiÃÃes dos cirurgiÃes dentistas a esses agentes pode ser um passo importante para o planejamento e estratÃgias de medidas de seguranÃa. / Os raios X sÃo bastante utilizados nas prÃticas mÃdicas e odontolÃgicas, mas sÃo agentes mutagÃnicos potentes capazes de induzir Ãs mutaÃÃes e aberraÃÃes cromossÃmicas. Este trabalho teve por objetivo avaliar os efeitos da radiaÃÃo ionizante induzida por raios X em cÃlulas esfoliadas da mucosa bucal de cirurgiÃes dentistas exposto ocupacionalmente, atravÃs da aplicaÃÃo do teste de micronÃcleos, para evidenciar nÃmero e freqÃÃncia de micronÃcleo, alÃm de outras anormalidades nucleares, como cÃlulas binucleadas, cariorrexe (fragmentaÃÃo nuclear) e cariÃlise (dissoluÃÃo nuclear). A idade da populaÃÃo estudada foi de 32 a 65 anos, representado por cirurgiÃes dentistas sendo 95% de brancos e 5% negros, enquanto que a nÃo exposta foi de 30% branco e 25% negros. Em relaÃÃo à exposiÃÃo a agentes quÃmicos e fÃsicos, os resultados mostraram que 100% dos cirurgiÃes dentistas se expÃem aos dois tipos de agentes. Nos Ãltimos dez anos, 65% dos expostos e 45% dos nÃo expostos realizaram raio X com fins terapÃuticos. Quanto ao tempo de trabalho, o grupo dos sujeitos com exposiÃÃo à radiaÃÃo ionizante supera o grupo dos nÃo expostos, 19,40  8,74 vs correspondendo de 11 a 32 anos nos expoxtos e 6,55  7,09 vs correspondendo de 11 a 25 anos nos nÃo expostos. Quanto ao uso de proteÃÃo, 100% de ambos os grupos nÃo utilizam proteÃÃo. A avaliaÃÃo mutagÃnica foi evidenciada pelo nÃmero de micronÃcleo em cÃlulas esfoliadas do epitÃlio bucal, 5,85  3,58 vs nos expostos e de 1,00  0,85 nos nÃo expostos, como tambÃm pela freqÃÃncia de micronÃcleo, sendo 0,41 0,27MN nos expostos e de 0,02  0,04 MN nos nÃo expostos, com significÃncia de p< 0,001 nos expostos em relaÃÃo aos nÃo expostos. As anormalidades nucleares como cariorrexe (39,49  16, 29 vs 16, 03  8,61), cariÃlise (6,92  5,87 x 1,11  0,99) e cÃlulas binucleadas(12,45  8,43 x 0,76  0,23), em relaÃÃo aos nÃo expostos, evidenciam apoptose, necrose e citotocixidade e foram estatisticamente significante p<0,01. NÃo foi encontrada correlaÃÃo positiva entre hÃbitos de vida, doenÃas genÃticas e a presenÃa de micronÃcleos ou anormalidades nucleares. Assim, os resultados deste trabalho indicam que as radiaÃÃes odontolÃgicas induzem danos ao material genÃtico de cÃlulas esfoliadas da mucosa bucal, ocasionando tambÃm aumento de apoptose, indicando que o uso deste procedimento deve ser requisitado somente quando necessÃrio. Este trabalho demonstra tambÃm a importÃncia de se avaliar as outras anormalidades nucleares e nÃo apenas os micronÃcleos como indicadores de danos ao DNA. A preocupaÃÃo com esses efeitos à pertinente, principalmente aos expostos ocupacionalmente, pois alÃm de estabelecer um prognÃstico da incidÃncia do desenvolvimento de cÃncer, a monitoraÃÃo das exposiÃÃes dos cirurgiÃes dentistas a esses agentes pode ser um passo importante para o planejamento e estratÃgias de medidas de seguranÃa. / X-rays are widely used in medical and dental practices, but are potent mutagens able to induce mutations and chromosomal aberrations. This study aimed to evaluate the effects of ionizing radiation-induced X-rays in exfoliated buccal mucosa cells of dentists exposed occupationally, through the application of the micronucleus test, to show the number and frequency of micronuclei, and other nuclear abnormalities such as binucleated cells, karyorrhexis (nuclear fragmentation) and karyolysis (nuclear dissolution). The age of the study population was 32 to 65 years, represented by dentists and 95% white and 5% were black, while the unexposed was 30% white and 25% were black. In relation to exposure to chemical and physical agents, the results showed that 100% of dentists are exposed to both types of agents. Over the past decade, 65% of those exposed and 45% of unexposed X-ray performed for therapeutic purposes. The working time, the group of subjects with exposure to ionizing radiation overcomes the unexposed group, 19.40  8.74 vs corresponding 11 to 32 years in expoxtos and 6.55  7.09 vs corresponding 11 to 25 years in the unexposed. Regarding the use of protection of 100% in both groups did not use protection. The assessment of mutagenicity was observed by the number of micronuclei in exfoliated cells of oral epithelium, vs. 5.85  3.58 in those exposed and 1.00  0.85 in the unexposed, but also by the frequency of micronuclei, and 0.41  0.27 MN in the exposed and 0.02  0.04 MN in unexposed, with a significance of p <0.001 in exposed compared to unexposed. Abnormalities such as nuclear karyorrhexis (39.49  16, 29 vs 16, 03  8.61), karyolysis (6.92  5.87 x 1.11  0.99) and binucleated cells (12.45  8 , 43 x 0.76  0.23) compared to unexposed, demonstrate apoptosis, necrosis and citotocixidade and were statistically significant p <0.01. No correlation was found between positive lifestyle habits, genetic diseases and the presence of micronuclei and nuclear abnormalities. Thus, the results of this study indicate that dental radiation induced damage to the genetic material of cells exfoliated buccal mucosa, also causing increased apoptosis, indicating that the use of this procedure should be ordered only when necessary. This work also demonstrates the importance of evaluating the nuclear and other abnormalities not only micronuclei as indicators of DNA damage. Concern about these effects is relevant mainly to the occupationally exposed, as well as establishing a prognosis of the incidence of cancer development, the monitoring of exposure of dentists to these agents can be an important step for planning strategies and security measures. / X-rays are widely used in medical and dental practices, but are potent mutagens able to induce mutations and chromosomal aberrations. This study aimed to evaluate the effects of ionizing radiation-induced X-rays in exfoliated buccal mucosa cells of dentists exposed occupationally, through the application of the micronucleus test, to show the number and frequency of micronuclei, and other nuclear abnormalities such as binucleated cells, karyorrhexis (nuclear fragmentation) and karyolysis (nuclear dissolution). The age of the study population was 32 to 65 years, represented by dentists and 95% white and 5% were black, while the unexposed was 30% white and 25% were black. In relation to exposure to chemical and physical agents, the results showed that 100% of dentists are exposed to both types of agents. Over the past decade, 65% of those exposed and 45% of unexposed X-ray performed for therapeutic purposes. The working time, the group of subjects with exposure to ionizing radiation overcomes the unexposed group, 19.40  8.74 vs corresponding 11 to 32 years in expoxtos and 6.55  7.09 vs corresponding 11 to 25 years in the unexposed. Regarding the use of protection of 100% in both groups did not use protection. The assessment of mutagenicity was observed by the number of micronuclei in exfoliated cells of oral epithelium, vs. 5.85  3.58 in those exposed and 1.00  0.85 in the unexposed, but also by the frequency of micronuclei, and 0.41  0.27 MN in the exposed and 0.02  0.04 MN in unexposed, with a significance of p <0.001 in exposed compared to unexposed. Abnormalities such as nuclear karyorrhexis (39.49  16, 29 vs 16, 03  8.61), karyolysis (6.92  5.87 x 1.11  0.99) and binucleated cells (12.45  8 , 43 x 0.76  0.23) compared to unexposed, demonstrate apoptosis, necrosis and citotocixidade and were statistically significant p <0.01. No correlation was found between positive lifestyle habits, genetic diseases and the presence of micronuclei and nuclear abnormalities. Thus, the results of this study indicate that dental radiation induced damage to the genetic material of cells exfoliated buccal mucosa, also causing increased apoptosis, indicating that the use of this procedure should be ordered only when necessary. This work also demonstrates the importance of evaluating the nuclear and other abnormalities not only micronuclei as indicators of DNA damage. Concern about these effects is relevant mainly to the occupationally exposed, as well as establishing a prognosis of the incidence of cancer development, the monitoring of exposure of dentists to these agents can be an important step for planning strategies and security measures.
230

Expressão dos genes EGFR, PTEN, MGMT e IDH1/2 e dos microRNAs miR-181b, miR-145, miR-149 e miR128a em neuroesferas em linhagens de glioblastoma submetidos ao tratamento com radiação ionizante e temozolomida / Expression of EGFR, PTEN, MGMT and IDH1 / 2 Genes and the MicroRNAs miR-181b, miR-145, miR-149 and miR-128a in Neurospheres In Glioblastoma Lineages Undergoing Treatment with Ionizing Radiation and Temozolomide

Thiago Lins da Costa Almeida 17 June 2016 (has links)
Introdução: O glioblastoma multiforme é a neoplasia maligna primária mais prevalente do sistema nervoso central. Enquanto apresenta aumento em sua incidência, mantém a perspectiva de sobrevida global aproximada de 14 meses. Objetivos: O presente estudo objetiva avaliar a expressão dos genes EGFR, PTEN, MGMT e IDH1/2 e dos microRNAs miR-181b, miR-145, miR-149 e miR-128a em neuroesferas (NE) e células aderidas (CA), a partir das linhagens celulares (T98G e U343) submetidas ao tratamento com temozolomida (TMZ) e com radiação ionizante (RI) isolados e em associação (TMZ+RI). Material e métodos: As linhagens celulares T98G e U343 foram tratadas com TMZ, RI e TMZ+RI. A verificação da expressão dos genes e miRNAs foi realizada utilizando o método de PCR em tempo real. Resultados: Observamos: a) o aumento na expressão do IDH1 após RI (4-fold) e TMZ+RI (5-fold) nas NE (T98G); o aumento na expressão do IDH2 (20-fold) nas NE (T98G), após TMZ, e do IDH2 (3-fold) nas CA (U343) submetidas à TMZ+RI; b) a redução na expressão do EGFR após TMZ; o aumento dessa expressão nas NE (T98G), após RI (2-fold) e TMZ+RI (3-fold), e a sua diminuição nas CA (U343) submetidas à TMZ e TMZ+RI; c) a redução na expressão PTEN nas NE (T98G), após TMZ e RI, e sua expressão nas NE (3-fold) frente à TMZ+RI; d) aumento na expressão de MGMT nas NE (T98G) nos grupos RI (10-fold) e TMZ+RI (25-fold). Quanto a expressão de miRNAs, foram identificados os seguintes resultados: a) as CA (U343) expressaram: miR-181b após TMZ (60-fold), RI (20-fold) e TMZ+RI (40- fold); e miR-128a após TMZ (500-fold), RI (200-fold) e TMZ+RI (600-fold); b) as NE (T98G) após TMZ+RI expressaram: miR-181b (30-fold), miR-149 (40-fold), miR-145 (300-fold) e miR-128a (40-fold); c) as NE (U343) após RI hiperexpressaram miR-149 e miR-145 (ambos em 4000-fold). Conclusão: A RI apresentou-se como fator independente e determinante para a radiorresistência das NE, entretanto não observamos ação de complementariedade de regulação dos oncomiRs observados sobre a expressão dos genes estudados. Esta é a primeira análise na literatura que correlaciona a expressão de genes e de miRNAs através das intervenções TMZ, RI e TMZ+RI sobre células aderidas e neurosferas. / Introduction: Glioblastoma multiforme is the most prevalent primary malignant neoplasm of the central nervous system. It has increased its incidence, while the overall survival remains over 14 months. Objectives: This study aims to evaluate the expression of the following genes EGFR, PTEN, MGMT and IDH1/2 and microRNAs miR-181b, miR-145, miR-149 and miR-128a in adhered cells (AC) and neurospheres (NS) from cell lines (T98G and U343) which were submitted to temozolomide (TMZ) and ionizing radiation (IR), isolated and associated (TMZ + IR). Methods: The cell lines T98G and U343 were treated with TMZ, IR and TMZ+IR. The analysis of gene expression and miRNAs was performed using the PCR in real time. Results: This study demonstrated: a) an improvement in the expression of IDH1 after IR (4-fold) and TMZ + IR (5-fold) in the NS (T98G); increased expression of IDH2 (20-fold) in the NS (T98G) after TMZ and IDH2 (3-fold) in AC (U343) submitted to TMZ + IR; b) reduction in EGFR expression after TMZ; increase this expression in NS (T98G) after IR (2-fold) and TMZ + IR (3-fold), and a decrease in AC (U343) submitted to TMZ and TMZ + IR; c) reduction in PTEN expression in NS (T98G) after TMZ and IR, and its improvement in NS (3-fold) when compared to TMZ + IR; d) increase in the expression of MGMT in NS (T98G) in IR groups (10-fold) and TMZ + IR (25-fold). It was also identified the expression of miRNAs results as: a) AC (U343) expressed more miR-181b after TMZ (60-fold), IR (20-fold) and TMZ + IR (40-fold); and miR- 128a improved after TMZ (500-fold), IR (200-fold) and TMZ + IR (600-fold); b) NS (T98G) after TMZ + IR expressed: miR-181b (30-fold); miR-149 (40-fold); miR-145 (300-fold) and miR-128a (40-fold); c) NS (U343) after IR huge expressed miR-149 and miR-145 (both in 4000-fold). Conclusion: IR was an independent and determining radio resistance factor in NS. However, we observed no complementarity action of oncomiRs regulation. This is the first study in the literature correlating gene expression, and miRNAs through TMZ, IR and IR + TMZ interventions in AC and NS.

Page generated in 0.1177 seconds