• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 205
  • 100
  • 32
  • 23
  • 15
  • 8
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 454
  • 454
  • 186
  • 183
  • 40
  • 38
  • 34
  • 32
  • 30
  • 30
  • 30
  • 29
  • 28
  • 27
  • 26
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Radiation response in human cells : DNA damage formation, repair and signaling

Gustafsson, Ann-Sofie January 2015 (has links)
Ionizing radiation induces a range of different DNA lesions. In terms of mutation frequency and mammalian cell survival, the most critical of these lesions is the DNA double-strand break (DSB). DSB left unrepaired or mis-repaired may result in chromosomal aberrations that can lead to permanent genetic changes or cell death. The complexity of the DNA damage and the capacity to repair the DSB will determine the fate of the cell. This thesis focuses on the DNA damage formation, repair and signaling after irradiation of human cells. Radiation with high linear energy transfer (LET) produces clustered damaged sites in the DNA that are difficult for the cell to repair. Within these clustered sites, non-DSB lesions are formed that can be converted into a DSB and add to the damage complexity and affect DSB repair and the measurement. Heat-labile sites in DNA are converted into DSB at elevated temperatures. We show that heat-released DSB are formed post-irradiation with high-LET ions and increase the initial yield of DSB by 30%-40%, which is similar to yields induced by low-LET radiation. DNA-PKcs, a central player in non-homologous end-joining (NHEJ), the major mammalian DSB repair pathway, has been found to be both up- and downregulated in different tumor types. In Paper II we show that low levels of DNA-PKcs lead to extreme radiosensitivity but, surprisingly, had no effect on the DSB repair. However, the fraction of cells in G2/M phase increased two-fold in cells with low levels of DNA-PKcs. The study continued in Paper IV, where cells were synchronized to unmask potential roles of DNA-PKcs in specific cell cycle phases. Irradiation of DNA-PKcs suppressed cells in the G1/S phase caused a delay in cell cycle progression and an increase in accumulation of G2 cells. Further, these cells showed defects in DNA repair, where a significant amount of 53BP1 foci remained after 72 h. This further strengthens the hypothesis that DNA-PKcs has a role in regulation of mitotic progression. Several cellular signaling pathways are initiated in response to radiation. One of these downstream signaling proteins is AKT. We identified an interaction between DNA-PKcs and AKT. Knockouts of both AKT1 and AKT2 impaired DSB rejoining after radiation and low levels of DNA-PKcs increased radiosensitivity and decreased DNA repair further.
192

Efeitos da radioterapia na obtenção da osseointegração em ratos / Effects of radiotherapy in obtaining osseointegration in rats

Kamezawa, Leonardo Silva Gomes 11 December 2017 (has links)
Submitted by Leonardo Silva Gomes null (drleonardosgomes@gmail.com) on 2018-01-22T00:28:55Z No. of bitstreams: 1 Dissertação corrigida.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Approved for entry into archive by Silvana Alvarez null (silvana@ict.unesp.br) on 2018-01-23T19:48:52Z (GMT) No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) / Made available in DSpace on 2018-01-23T19:48:52Z (GMT). No. of bitstreams: 1 kamezawa_lsg_me_sjc.pdf: 2116172 bytes, checksum: f055c6caaf0bf0c28d76947eacf9e78c (MD5) Previous issue date: 2017-12-11 / A radioterapia é o uso da aplicação de radiação ionizante em áreas específicas, visando tratamento de tumores. Porém, a área irradiada e os tecidos normais circundantes estão sujeitos a danos agudos e crônicos. As injúrias no tecido ósseo variam desde osteopenia até osteorradionecrose e, devido a estas alterações, pacientes irradiados portadores de implantes vêm demonstrando maior taxa de insucesso. O objetivo deste estudo foi avaliar os efeitos da radioterapia, simulando uma dose total de um tratamento radioterápico convencional para pacientes oncológicos, na neoformação óssea e na osseointegração de implantes em fêmures de ratos. Foram utilizados neste estudo 66 ratos que receberam implantes cilíndricos de titânio comercialmente puro (TiCp) nos fêmures direito e esquerdo. Os animais foram divididos em 3 grupos: a) Grupo controle (C): cirurgia de colocação dos implantes (tecido sadio sem irradiação); b) Grupo irradiação precoce (Ip): cirurgia de colocação dos implantes seguido de irradiação após 24h; c) Grupo irradiado (I): irradiação e após 4 semanas, cirurgia de colocação dos implantes. Os animais dos grupos Ip e I foram submetidos a irradiação em 02 sessões de 15 Gy, totalizando a dose de 30 Gy. Os animais foram eutanasiados nos períodos de 2 e 7 semanas após o tratamento. Durante o experimento, os animais foram cuidadosamente monitorados quanto as alterações clínicas. Em cada período, 06 animais foram submetidos à análise histomorfométrica, visando avaliar a neoformação óssea e a interface osso-implante. Os outros 05 animais, dos períodos de 2 e 7 semanas após o tratamento, foram submetidos ao teste de torque reverso para avaliar a força de fixação osso-implante, obtida na osseointegração. Todos os dados foram estatisticamente analisados por meio da análise de variância de 2 fatores para torque reverso, porcentagem de área de formação óssea (BAFO) e porcentagem de superfície de contato osso implante (BIC) com nível de significância a 5%. O teste de Tukey foi realizado para determinação dos grupos homogêneos. A irradiação ionizante influenciou negativamente de maneira estatisticamente significante, retardando o processo de osseointegração, porém, não sendo capaz de inibí-lo. / The radiotherapy is ionizing radiation proceeding in specific areas, aiming at the treatment of tumors. However, the irradiated area and the surrounding normal tissue can develop acute and chronic damage. In bone tissue, injuries ranging from osteopenia to osteroadionecrosis and due to these changes patients irradiated with implants have shown higher failure rate. The objective of this study was to evaluate the effects of radiation, simulating a total dose of a conventional radiotherapy treatment for cancer, bone regeneration and osseointegration of implants in femurs of rats. It was used in this study 66 mice that receive cylindrical implants of commercially pure titanium (cpTi) on the right and left femurs. The animals were divided into 3 groups: a) control group (C): implant placement surgery (control group - healthy tissue without irradiation); b) Group early irradiation (Ip): placement of implants surgery followed by radiation after 24h; c) Group irradiated (I): irradiation and after 4 weeks of surgery implant placement. The animals of the Ip and I groups were subjected to irradiation in a double step at a dose of 15 Gy each, totalizing dose of 30 Gy. The animals were euthanized at periods of 2 and 7 weeks after treatment. During the experiment, the animals were carefully monitored for clinical changes. In each period 06 animals were submitted to histomorphometric analysis, to evaluate the bone formation and boneimplant interface. The other 05 animals, in periods of 2 and 7 weeks after treatment, were submitted to the reverse switch test to evaluate the strength of bone-implant fixation, obtained in osseointegration. All data were statistically analyzed by means of the 2-factor variance analysis for reverse torque, percentage of bone area fraction occupancy (BAFO) and percentage of bone implant contact (BIC) with significance level at 5%. The Tukey test was performed to determine the homogeneous groups. The ionizing radiation influenced negatively in a statistically significant way, delaying the process of osseointegration, but not being able to inhibit it.
193

Efeitos de raios-X de baixa energia em células mamárias / Effects of low energy x-rays in mammary cells

Flávia Ventura dos Passos 12 August 2011 (has links)
Doses de radiação de baixa energia podem induzir quebras de dupla fita no DNA assim como também produzir perfis alterados de expressão de genes relacionados a estas lesões. Os danos não reparados ou mal reparados levam a uma maior suscetibilidade à transformação oncogênica já que os efeitos biológicos mais importantes causados pela radiação ionizante são mutação e carcinogênese. As lesões no DNA provocadas pela radiação podem também ocasionar o surgimento micronúcleos e as células podem ser induzidas à apoptose. O objetivo deste trabalho é estudar in vitro a presença de micronúcleos e a apoptose ocasionados por Raios-X de baixa energia. Pretende-se analisar estes efeitos biológicos em relação à energia equivalente à utilizada em exames mamográficos usando duas linhagens estabelecias de células de mama: a MCF-7 (tumoral) e a HB-2 (não-tumoral). As células, em crescimento exponencial, foram irradiadas no equipamento de arranjo experimental de mamografia do LCR/UERJ. A dose de 5Gy na energia de 30 kV foi aplicada com taxa de 0,1 Gy/seg utilizando filtro de 0,03 mm de molibdênio. As irradiações foram realizadas duas vezes, após as irradiações, as células foram incubadas por 4, 24 ou 48 horas e posteriormente coradas com o corante Hoechst33258 para análise em microscopia de fluorescência. Para cada análise, 1000 células foram categorizadas pela morfologia do núcleo. Os resultados mostraram que a HB-2, utilizada neste estudo como célula mamária normal, apresentou maior sensibilidade aos efeitos da radiação, com 37 % das células em apoptose após 4 hs de incubação, enquanto a MCF-7 apresentou 6,5 %. Nas análises após 24 hs foi possível confirmar a radioresistência da MCF-7 tendo sido observadas 11% de células em apoptose no grupo irradiado. Houve um aumento crescente de micronúcleos radioinduzidos nas duas linhagens de acordo com os tempos de incubação. Na análise de 4 hs a HB-2 apresentou 3%, em 24 hs, 8,5% e 48 hs, 11,5 %. Diante destes resultados, foi possível concluir que a energia do feixe de raios-X utilizada na mamografia pode ser capaz de ocasionar aumento de ocorrência de apoptose e geração de micronúcleos nas duas linhagens estudadas / Radiation doses of low-energy can induce double-stranded breaks in DNA as well resulting in altered profiles of gene expression related to these injuries. The damage is not repaired or poorly repaired leading to increased susceptibility to oncogenic transformation since most important biological effects caused by ionizing radiation are mutation and carcinogenesis. The DNA lesions caused by radiation can also provoke the presence of micronuclei and as result cells can be induced to apoptosis. The aim of this work is to perform a preliminary study "in vitro" to identify the presence of micronuclei caused by low energy. X-rays. It is intended analyze these biological effects caused by x-rays with energy equivalent to the ones used in mammography in two very well established breast: cell lines the MCF-7 (tumor) and HB-2 (non-tumor). Cells in exponential growth were irradiated using an experimental arrangement with a mammography tube of the LCR / UERJ. The dose of 5Gy was used for 30 kVp x-rays using 0.03 mm filter molybdenum with a fixed dose rate of 0.1 Gy / sec. The irradiations were repeated twice and. the cells were incubated for 4, 24 or 48 hours and stained with dye Hoechst 33258 for fluorescence microscopy analysis. For each analysis 1000 cells were categorized by the morphology of the nucleus. The results revealed that the HB-2, used in this study as normal mammary cell have showed high sensitivity to the effects of radiation, with 37% of cells undergoing apoptosis after incubation of 4hs, while MCF-7 showed 6.5%. In the 24 hour-analysis it was confirmed the radiation resistance of MCF-7 were it was observed 11% of cells in apoptosis in the irradiated group. There was an increasing number of radiation-induced micronuclei in both cell lines, according to the incubation times. After 4 hours, HB-2 presented 3% of micronuclei, in 24 hours, the experiment reveled 8.5%, and after 48 hours it increased to 11.5%. As result of this study we may conclude that the energy used in mammography is capable to cause an increase in incidence of apoptosis and in the production of micronuclei in both cell lines studied
194

Efeitos da radiação ionizante e eventos singulares em circuitos analógicos de baixo e ultra baixo consumo

Fusco, Daniel Alves January 2016 (has links)
Esse trabalho apresenta um estudo sobre os efeitos de radiação em circuitos analógicos de baixa e ultra baixa potência e tensão, identificando as fragilidades destes circuitos (e das respectivas técnicas de projeto) quando aplicados em ambientes radioativos, como, por exemplo, os circuitos em satélites, e em equipamentos de instalações nucleares. Foram realizados estudos de caso, via simulação elétrica utilizando o software HSPICE, considerando os efeitos de degradação elétrica correspondentes a doses de radiação acumulada de até 500krad(Si), além de eventos singulares considerando circuitos de baixa tensão e potência projetados para a tecnologia IBM (GF) de 130nm. Pôde-se observar que o uso de transistores de óxido mais fino, apesar de afetar negativamente o consumo estático, é recomendado para as aplicações estudadas, devido a menor sensibilidade à radiação. Ainda, foi discutido o aumento dos caminhos de fuga de corrente devido ao uso de layout distribuído. Possibilidades e estratégias de mitigação foram discutidas. Por fim, obteve-se um conjunto de sugestões e informações para auxiliar o projetista de circuitos de baixo consumo a obter soluções robustas à radiação. / This work studies the radiation effects in low-power and ultra-low power analog circuits, identifying the fragility of such circuits (and associated design techniques) when employed in radioactive environments, as for example, in satellites and nuclear facilities. Case studies were carried out using HSPICE software for electrical simulation of cumulative radiation effects, corresponding to doses up to 500krad(Si), as well as for single events simulation. We showed that, the use of thin oxide (core) MOSFETS, though increasing the static consumption, is recommended for the studied applications, because they are less sensitive to radiation. Then, we discussed the increase of current leakage paths by the distributed layout style. Mitigation strategies were also discussed. Finally, we obtained a set of suggestions and information to guide the designers of low power analog circuits towards obtaining radiation robust solutions.
195

Estudo de propriedades dosimétricas utilizando polímero organometálico em solução /

Fernandes, David Moreira. January 2012 (has links)
Orientador: Carlos Frederico de Oliveira Graeff / Coorientador: Erika Soares Bronze-Uhle / Banca: Francisco Eduardo Gontijo Guimarães / Banca: Marco Antonio Rodrigues Fernandes / O Programa de Pós Graduação em Ciência e Tecnologia de Materiais, PosMat, tem carater institucional e integra as atividades de pesquisa em materiais de diversos campi / Resumo: Este trabalho teve como objetivo estudar as características dosimétricas do polímero "poly-[1,1-bis(ethynyl)-4,4-bipheny(bis-tributylphosphine)Pt(11)]" (Pt-DEBP) frente à radiação gama. Para realização dos experimentos dissolveu-se o polímero Pt-DEBP, contendo dez unidades monoméricas, em solventes orgânicos - clorofórmio e totueno. As amostras foram irradiadas em quatro concentrações (0,0500; 0,0375; 0,0250; 0,0113 mg/mL) e em duplicatas, com doses que variaram de 1 a 90 Gy. Os resultados foram avaliados com base em técnicas espectroscópias, como a espectroscopia de absorção óptica (UV-VIs), fluorescência (emissão), fluorescência com resolução temporal (FRT) e infravermelho com transformada de Fourier (FTIR). Para soluções de Pt-DEBP em clorofórmio, nota-se uma alteração na posição da banca principal (л-л *) de absorção óptica para menores comprimentos de onda (blue-shift), aliado a uma diminuição da intensidade de absorção, á medida em que se aumenta a dose de radiação. Na espectroscopia de fluorescência, observou-se um deslocamento para maiores comprimentos de onda (red-shift) aliado a um aumento de intensidade na banda de emissão com aumento da dose de radiação. Experimentos de FRT, das amostras irradiadas em clorofórmio indicam a presença de um novo centro emissor. Os espectros de infravermelho com transformada de Fourier (FTIR) comprovam a entrada de cloro na cadeia polimérica, justificando o blue-shift obervado nos espectros de absorção e o novo centro emissor responsável pela alteração nos espectros de emissão. Além disso, foi analisado o comportamento linear dos resultados obtidos nos estudos de absorção e fluorescência, tomando como base a relação entre comprimento de onda máxima de absorção com a dose e, para o segundo caso, a relação entre... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This work aimed to study the dosimetric characteristics of the polymer of the polymer"poly-[1,1-bis (ethynyl) -4,4 biphenyl (bis-tributylphosphine) Pt (II)]" (Pt-DEBP) compared to radiation gamma. The Pt-DEBP polymer, containing ten monomer units, was then dissolved in organic solvents as chloroform and toluene. The samples were irradiated at four concentrations (0.0500, 0.250, 0.0113 mg / mL) in duplicate, with radiation doses ranging from 1 to 90 Gy. The results were evaluated based on spectroscopic techniques such as optical absorption spectroscopy (UV-Vis), fluorescence (emission), time resolved fluorescence (FRT) and Fourier transform infrared (FTIR). For DEBP-Pt solutions in chloroform, there is a shift in the position of the main optical absorption band (л-л *) to lower wavelength (blue-shift), allied to a decreasing absorption intensify with increasing radiation dose. In fluorescence spectroscopy, there was a shift to longer wavelengths (red-shift) allied to an increasing emission intensify with increasing radition dose. FRT experiments on irradiated samples dissolved in chloroform indicated the presence of a new emitter center. FTRI spectra show the incorporation of chlorine in polymer chain, justifying the blue-shift observed in the absorption spectra and the new emission center. In addition, the behavior of linear results in the aborption and fluorescence studies was investigated based on the relationship between the wavelength of maximum absorption/emission and the radiation dose. For both cases, a linear behavior was observed in relation to the sample concentration. Repeatability and stability tests were also performed. For the samples dissolved in tolluene, there was no significant shift of the spectrum of absorption or fluorescence for all doses. The results show that the Pt-DEBP polymer dissolved in chloroform can be used as a dosimer for y-ray doses between... (Complete abstract click electronic access below) / Mestre
196

Efeitos da radiação ionizante e eventos singulares em circuitos analógicos de baixo e ultra baixo consumo

Fusco, Daniel Alves January 2016 (has links)
Esse trabalho apresenta um estudo sobre os efeitos de radiação em circuitos analógicos de baixa e ultra baixa potência e tensão, identificando as fragilidades destes circuitos (e das respectivas técnicas de projeto) quando aplicados em ambientes radioativos, como, por exemplo, os circuitos em satélites, e em equipamentos de instalações nucleares. Foram realizados estudos de caso, via simulação elétrica utilizando o software HSPICE, considerando os efeitos de degradação elétrica correspondentes a doses de radiação acumulada de até 500krad(Si), além de eventos singulares considerando circuitos de baixa tensão e potência projetados para a tecnologia IBM (GF) de 130nm. Pôde-se observar que o uso de transistores de óxido mais fino, apesar de afetar negativamente o consumo estático, é recomendado para as aplicações estudadas, devido a menor sensibilidade à radiação. Ainda, foi discutido o aumento dos caminhos de fuga de corrente devido ao uso de layout distribuído. Possibilidades e estratégias de mitigação foram discutidas. Por fim, obteve-se um conjunto de sugestões e informações para auxiliar o projetista de circuitos de baixo consumo a obter soluções robustas à radiação. / This work studies the radiation effects in low-power and ultra-low power analog circuits, identifying the fragility of such circuits (and associated design techniques) when employed in radioactive environments, as for example, in satellites and nuclear facilities. Case studies were carried out using HSPICE software for electrical simulation of cumulative radiation effects, corresponding to doses up to 500krad(Si), as well as for single events simulation. We showed that, the use of thin oxide (core) MOSFETS, though increasing the static consumption, is recommended for the studied applications, because they are less sensitive to radiation. Then, we discussed the increase of current leakage paths by the distributed layout style. Mitigation strategies were also discussed. Finally, we obtained a set of suggestions and information to guide the designers of low power analog circuits towards obtaining radiation robust solutions.
197

Možná rizika zneužívání radioaktivních materiálů z bývalé úpravny uranových rud MAPE Mydlovary / Possible risks of abuse of radioactive materials from the former uranium ore processing plant MAPE Mydlovary.

ŘEPA, Libor January 2012 (has links)
Possible risks of using radioactive materials are a highly discussed topic nowadays. This work is dealing with this problem and it is focused on possible risks of using radioactive materials from the ex-treatment plant of uranium ores MAPE Mydlovary. In introductory chapters I am describing the current state of ex-treatment plant of uranium ores. I am dealing with the history of operation of MAPE, information about sludge lagoons and about stored sediments in them and other characteristics concerning this operation. For years, sediments in which radionuclides are contained have been stored in treatment plants and that is why I am dealing with ionizing radiation. Because the topic is the using of radioactive materials which can be used mainly by terrorists, I am also describing this worldwide phenomenon of recent years where I first of all focused on super-terrorism using radioactive weapons, namely so-called ?dirty bombs?. The target of this work is to find out possibilities of using radioactive materials from the ex-treatment plant. Therefore I measured values of radioactivity and exposition of radiation at some places with the help of exploratory research. That meant sampling of soils and water and also measurement of power of dose equivalent of radiation gamma. After gathering information of needed radiation values I carried out simulation of possible using of radioactive materials from the premises MAPE. By means of dirty bomb I used the programme TerEx at using radioactive material. Then I carried out several calculations which were focused on inhalation, ingestion or outdoor radiation from radioactive materials and also calculation how much it is necessary to gain a significant source of ionizing radiation. From these sources I have deduced impacts for individuals, society or environment. Based on analysis and evaluation of given problems, my set hypothesis ?By using radioactive materials from the ex-treatment plant of uranium ores MAPE Mydlovary a serious threat to people will not occur? was confirmed. Results of my work can be used as a study material for completing and broadening knowledge about risks resulting from using radioactive materials. Further an increase of foreknowledge and explanation of certain consequences of ionizing radiation on humans from materials from the ex-treatment plant of uranium ores MAPE Mydlovary, for inhabitants of Mydlovary and surrounding areas and also useful information for lay and professional society which is interested in these problems.
198

Exposição à radiação ionizante dos profissionais de saúde em hemodinâmica: o enfoque da enfermagem / Exposure of health professionals to ionizing radiation at hemodynamic: the nursing's vision

Katia Maria dos Santos Calegaro 18 December 2007 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / As radiações ionizantes têm sido cada vez mais usadas na medicina contemporânea, inserida em contextos diagnósticos e terapêuticos. O objeto deste estudo foi, portanto, a exposição à radiação ionizante relacionada ao processo de trabalho dos profissionais de saúde em hemodinâmica e seus objetivos foram conhecer o perfil dos trabalhadores de saúde que atuam no setor de hemodinâmica, levantar os problemas de saúde provocados ou agravados pelo trabalho a partir da ótica do profissional, conhecer as doses ocupacionais dos trabalhadores, correlacionando os dados encontrados à luz da legislação específica vigente. Tratou-se de um estudo exploratório e descritivo com abordagem quanti-qualitativa que teve como instrumentos de coleta de dados: a observação sistemática do local de estudo, lê-se, o setor de hemodinâmica de um hospital universitário localizado na cidade do Rio de Janeiro; a aplicação de um questionário com 35 perguntas abertas e fechadas aos sujeitos do estudo, lê-se, os profissionais de saúde médicos, enfermeiros, técnicos de enfermagem e técnicos de radiologia que atuavam no setor de hemodinâmica; e a busca documental pelas doses ocupacionais retrospectivas dos trabalhadores. Como resultados, identificou-se uma população com média de 39 anos, com experiência profissional média, em saúde e hemodinâmica, de 10 anos, que trabalham em mais de uma instituição de saúde expostos à radiação ionizante. Foram discutidas questões relativas à saúde, segurança, formação e prática profissional dos sujeitos à luz das legislações que versam sobre o uso de radiações ionizantes. Concluiu-se a necessidade de adaptações e mudanças em diversas esferas / setores objetivando a otimização da radioproteção, da saúde dos trabalhadores e da prática em hemodinâmica. / Ionizing radiations have been used in the contemporary medicine, inserted in disgnostic and therapeutical contexts. Therefore, the object of this study was the relation among ionizing radiation exposition and the work process of the health professionals at hemodynamic; the objectives were: know the profile of the professionals working at hemodynamic unit, identify health problems caused or aggravated by work on the workers agreement, know the occupational dosis of this professionals and correlate data with the specific current law. This is a descriptive study, quanti-qualitative that had like data collection instruments: a systematic observation of an hemodynamic unit located in an university hospital in Rio de Janeiro; application of a questionnaire with 35 open and closed questions to population healths professionals: physicians, nurses, radiology technicians and nursing technicians - that works at hemodynamics, and a documentary search about their last occupational dosis. The results of this study shows a population with average age of 39 years, with a lot of professional experience, in health and hemodynamic (10 years in average), that work at more than one health institution exposed to ionizing radiation. Questions about health, security, graduation and professional practice had been analyzed and argued based in the specific legislation. The conclusions are a necessity of adaptations and changes in diverse sectors objectifying the optimization of radioprotection, workers health and the practice at hemodynamics units.
199

Efeitos de raios-X de baixa energia em células mamárias / Effects of low energy x-rays in mammary cells

Flávia Ventura dos Passos 12 August 2011 (has links)
Doses de radiação de baixa energia podem induzir quebras de dupla fita no DNA assim como também produzir perfis alterados de expressão de genes relacionados a estas lesões. Os danos não reparados ou mal reparados levam a uma maior suscetibilidade à transformação oncogênica já que os efeitos biológicos mais importantes causados pela radiação ionizante são mutação e carcinogênese. As lesões no DNA provocadas pela radiação podem também ocasionar o surgimento micronúcleos e as células podem ser induzidas à apoptose. O objetivo deste trabalho é estudar in vitro a presença de micronúcleos e a apoptose ocasionados por Raios-X de baixa energia. Pretende-se analisar estes efeitos biológicos em relação à energia equivalente à utilizada em exames mamográficos usando duas linhagens estabelecias de células de mama: a MCF-7 (tumoral) e a HB-2 (não-tumoral). As células, em crescimento exponencial, foram irradiadas no equipamento de arranjo experimental de mamografia do LCR/UERJ. A dose de 5Gy na energia de 30 kV foi aplicada com taxa de 0,1 Gy/seg utilizando filtro de 0,03 mm de molibdênio. As irradiações foram realizadas duas vezes, após as irradiações, as células foram incubadas por 4, 24 ou 48 horas e posteriormente coradas com o corante Hoechst33258 para análise em microscopia de fluorescência. Para cada análise, 1000 células foram categorizadas pela morfologia do núcleo. Os resultados mostraram que a HB-2, utilizada neste estudo como célula mamária normal, apresentou maior sensibilidade aos efeitos da radiação, com 37 % das células em apoptose após 4 hs de incubação, enquanto a MCF-7 apresentou 6,5 %. Nas análises após 24 hs foi possível confirmar a radioresistência da MCF-7 tendo sido observadas 11% de células em apoptose no grupo irradiado. Houve um aumento crescente de micronúcleos radioinduzidos nas duas linhagens de acordo com os tempos de incubação. Na análise de 4 hs a HB-2 apresentou 3%, em 24 hs, 8,5% e 48 hs, 11,5 %. Diante destes resultados, foi possível concluir que a energia do feixe de raios-X utilizada na mamografia pode ser capaz de ocasionar aumento de ocorrência de apoptose e geração de micronúcleos nas duas linhagens estudadas / Radiation doses of low-energy can induce double-stranded breaks in DNA as well resulting in altered profiles of gene expression related to these injuries. The damage is not repaired or poorly repaired leading to increased susceptibility to oncogenic transformation since most important biological effects caused by ionizing radiation are mutation and carcinogenesis. The DNA lesions caused by radiation can also provoke the presence of micronuclei and as result cells can be induced to apoptosis. The aim of this work is to perform a preliminary study "in vitro" to identify the presence of micronuclei caused by low energy. X-rays. It is intended analyze these biological effects caused by x-rays with energy equivalent to the ones used in mammography in two very well established breast: cell lines the MCF-7 (tumor) and HB-2 (non-tumor). Cells in exponential growth were irradiated using an experimental arrangement with a mammography tube of the LCR / UERJ. The dose of 5Gy was used for 30 kVp x-rays using 0.03 mm filter molybdenum with a fixed dose rate of 0.1 Gy / sec. The irradiations were repeated twice and. the cells were incubated for 4, 24 or 48 hours and stained with dye Hoechst 33258 for fluorescence microscopy analysis. For each analysis 1000 cells were categorized by the morphology of the nucleus. The results revealed that the HB-2, used in this study as normal mammary cell have showed high sensitivity to the effects of radiation, with 37% of cells undergoing apoptosis after incubation of 4hs, while MCF-7 showed 6.5%. In the 24 hour-analysis it was confirmed the radiation resistance of MCF-7 were it was observed 11% of cells in apoptosis in the irradiated group. There was an increasing number of radiation-induced micronuclei in both cell lines, according to the incubation times. After 4 hours, HB-2 presented 3% of micronuclei, in 24 hours, the experiment reveled 8.5%, and after 48 hours it increased to 11.5%. As result of this study we may conclude that the energy used in mammography is capable to cause an increase in incidence of apoptosis and in the production of micronuclei in both cell lines studied
200

Použití přenosného spektrometru pro detekci radionuklidů v přepravovaných materiálech / Radionuclide detection in transported materials by a portable spectrometer.

PLAŇANSKÝ, Jiří January 2018 (has links)
The aim of my diploma thesis was to assess possibilities of tracing and, consequently, identifying radionuclides in transported materials detected by detection frames on the protected area border of the nuclear power plant of Temelín, by means of the portable spectrometer Inspector 1000. To achieve this, I designed a series of measurements based on a simulated passage of a motor vehicle fitted with ionizining radiation sources of various activities at the designed points of measurement so that these measurements corresponded as close as possible to the actual passage of vehicles with large-sized loads. Recorded values were analysed and marginal activities for the particular measuring points were fixed. Computation correctness was then verified by another passage of the vehicle through the measuring device. Specified values of the marginal activities at the particular measuring points were, for comparison, consequently measured by the portable spectrometer Inspector 1000. Measurement results proved that the portable spectrometer Inspector 1000 can efficiently detect, identify and locate the sources of ionizing radiation causing the alarm level to be exceeded on a stable measuring device at the fixed measuring points, with a higher sensitivity than a stable measuring device. Conclusions of this diploma thesis will be given to the radiation protection unit of the nuclear power plant of Temelín as a basis for specification or even expansion of the methods of measuring ionizining radiation sources when transporting large-sized loads in the nuclear power plant, and their introduction into the monitoring programme.

Page generated in 0.7195 seconds