• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 14
  • 10
  • 7
  • 6
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Tratamento eletroquímico e eletroquímico irradiado do corante vermelho de alizarina S / Electrochemical and irradiated electrochemical treatment of alizarin red S dye

Moreira, Eduardo Marques 14 October 2011 (has links)
O vermelho de alizarina S é um corante cuja cor é função do pH. É uma antraquinona sulfonada que possui dois grupos fenólicos ligados ao mesmo anel onde se encontra o grupo sulfônico. Usualmente é comercializado sob a forma de sal monossódico, também chamado alizarinossulfonato de sódio ou simplesmente vermelho de alizarina. Esse corante pode ser sintetizado pela oxidação e hidroxilação do antraceno, seguida de sua sulfonação. Ele é largamente empregado em histoquímica, análises quantitativas e em indústrias têxtil e de couros. Na indústria de couros, esse corante vem acompanhado de grandes cargas de íon cloreto, o que é vantajoso para a aplicação de eletrodos ADE&reg no tratamento eletroquímico e fotoquímico eletro-assistido desse corante, haja vista que esses eletrodos são capazes de produzir espécies de cloro ativo altamente oxidantes, como gás cloro em pH fortemente ácido (< 2,00). Nesse trabalho foram empregados tratamentos eletroquímicos (puro e eletroquímico foto-assistido) para tratar o vermelho de alizarina S. Foram feitos estudos de densidade de corrente, concentração de cloreto de sódio, temperatura e investigação da natureza dos processos eletroquímicos irradiados. Para monitorar as degradações foram empregadas as técnicas de UV-Vis, DQO, COT, AOX e CLAE-MS. Percebeu-se que a concentração de cloreto de sódio e a corrente influenciam diretamente na velocidade de descoloração. Também foi possível notar que a regra de Van\'t Hoff equilibra-se com a regra de solubilidade dos gases em estudos de temperatura. Observou-se ainda que a irradiação aumenta muito o rendimento oxidativo das degradações, além de diminuir a quantidade de AOX gerados no produto final. Notou-se também que diminuindo a concentração de corante, a constante de velocidade de descoloração aumenta. Para monitorar os materiais eletródicos, foram empregadas as técnicas de VC, EDX e MEV. Constatou-se que eletrodos de composição Ti/Ir1-xSb1-ySn1-zO2 com baixo teor de Ir não são mecânica e eletroquimicamente resistentes, sendo necessário aumentar a concentração desse elemento e de Sb no material eletródico para incrementar a eficiência e a estabilidade. Palavras chave: Vermelho de alizarina S, ânodo dimensionalmente estável, cloreto, tratamento eletroquímico, tratamento eletroquímico irradiado / Alizarin red S is a dye whose color is a function of pH. It is a sulfonated anthraquinone which has two phenolic groups connected to the same ring where there is the sulphonic group. It is usually commercialized in the form of monossodic salt, also called sodium alizarinessulphonate or simply alizarin red. This dye can be synthesized by oxidation and hidroxilation of anthracene, followed by sulphonation reaction. It is largely used in histochemistry, quantitative analysis, textile and leather industries. In leather industry, this dye is accompanied by large quantities of chloride ions, which is advantageous for the application of DSA&reg electrodes in electrochemical or photo-assisted electrochemical treatment. This electrodes are capable of producing chlorine species, highly active oxidants such as chlorine gas in strongly acid pH (< 2.00). In this work we employed pure electrochemical and photo-assisted electrochemical treatments to degrade alizarin red S. The current density, concentration of sodium chloride, temperature parameters and the nature of irradiated electrochemical process were studied. To monitor the degradation were employed techniques of UV-Vis, COD, TOC, AOX and HPLC-MS. It was noticed that the sodium chloride concentration and the current directly influence in the rate of discoloration. It was also possible to note that the Van\'t Hoff rule is balanced with the gases solubility rule in temperature studies. It was observed that irradiation increases the efficiency of oxidation and reduce the amount of AOX generated in the final product. It was also noted that lowering the concentration of dye, the discoloration rate constant increases. To monitor the electrodic materials were used CV, SEM and EDX techniques. It was found that electrodes of Ti/Ir1-(x+y)SbxSnyO2 with low quantities of Ir are not mechanically and electrochemically resistant. Because this, it is necessary to increase the concentration of Sb and Ir elements in electrodic material to increase efficiency and stability. Key words: Alizarin red S, dimensionally stable anode, chloride, electrochemical treatment, irradiated electrochemical treatment
12

[en] METROLOGICAL EVALUATION OF THE RADIATION FIELD SIZE BY LINEAR ACCELERATORS / [pt] AVALIAÇÃO METROLÓGICA DO TAMANHO DE CAMPO IRRADIADO POR ACELERADORES LINEARES

NILMARA ALMEIDA GUIMARÃES 30 August 2018 (has links)
[pt] O objetivo desta dissertação é o estudo de procedimentos para avaliação da confiabilidade metrológica do tamanho de campo irradiado (TCI) por aceleradores lineares. No contexto das recentes alterações no panorama regulamentar dos serviços de radioterapia, com a implementação da RDC número 20, em 2006, pela Agência Nacional de Vigilância Sanitária (ANVISA), foi estabelecida a compulsoriedade do uso do densitômetro óptico na verificação do TCI, como parte do controle da qualidade. Questões associadas à implementação prática dos recentes requisitos para medição do tamanho de campo irradiado e as recentes indicações do potencial uso de filmes radiocrômicos para o controle da qualidade em radioterapia motivaram a realização do presente trabalho. Foram empregados três diferentes procedimentos para avaliação do tamanho de campo irradiado por aceleradores lineares utilizados em treze serviços de radioterapia localizados no Estado do Rio de Janeiro, utilizando filmes radiocrômicos EBT QD mais, RTQA, densitômetro óptico DensiX tipo T52001 ou scanner de transmissão Microtek. Os resultados destacam a contribuição das fontes de incerteza de medição para cada procedimento realizado e indicam a necessidade de considerá-la na avaliação da conformidade utilizando o densitômetro óptico (DO). Devido às propriedades do filme radiocrômico RTQA, o mesmo não pode ser utilizado no procedimento de medição com DO. Em conclusão, o uso do procedimento de medição utilizando scanner mostrou-se mais adequado para avaliação das dimensões de campos de radiação não-homogêneos. / [en] The objective of the present work is to study different procedures for metrological evaluation of the size of the radiation field emitted by linear accelerators. In the context of the recent requirements determined by the publication of the RDC number 20, in 2006, by National Agency for Sanitary Vigilance (Anvisa), the compulsory use of the optical densitometer for the measurements of the field size during quality control tests was introduced. Practical implementation issues associated with these requirements and the recent studies indicating the potential use of radiochromic films for measurements of the field size motivated the present work. Three different procedures were employed in order to evaluate the radiation field size emitted by linear accelerators used in thirteen radiotherapy services located in Rio de Janeiro, using radiochromic films EBT QD plus and RTQA, optical densitometer DensiX type T52001 or scanner Microtek. The results indicate the contribution of the measurement uncertainty associated to each procedure performed, highlighting the importance of its consideration during tests for conformity assessment with the recently required optical densitometer. Nevertheless, the RTQA radiochromic film properties precluded its use in the procedure using optical densitometer. In conclusion, among the evaluated procedures for radiation field evaluation, the use of the scanner was the most appropriate, especially if dimensional non-homogeneities are present.
13

Reparo em osso irradiado utilizando enxerto ósseo autógeno associado a plasma rico em plaquetas: análise histomorfométrica em coelhos

Scartezini, Guilherme Romano 17 December 2008 (has links)
The aim of this study was to observe the repair in irradiated bone using autogenous bone graft associated with platelet-rich plasma in rabbit model. Twelve New Zealand White rabbits were divided into two equal groups: irradiated (I) and non-irradiated (II), which were divided into subgroups: control (left tibiae) and PRP (right tibiae). The irradiated group received a single dose of 15 Gy in the tibiae bone. After forty-five days, in groups I and II, were created lesions in the tibiae, with trephine of 5 mm of diameter. The lesions were filled with autogenous bone grafts with PRP (test group) or without PRP (control group). After four weeks, the animals were sacrificed and the grafted regions were removed, fixed in formalin in PBS, demineralized in EDTA and embedded in paraffin. The histological images were captured at 4X magnification and submitted to the process of Targeting Interactive, as recommended by Oliveira et al. (2006). The region of bone matrix was called Region of Interest (ROI) and the percentage of matrix by area was obtained and analyzed through algorithms developed in the programming environment Scilab. The data were processed using the tests Kolmogrorov-Smirnov and paired ttest student and not paired. The statistical analysis of irradiated and nonirradiated groups showed no significant difference between test and control groups. Also, there s no significant difference between groups irradiated and non-irradiated. According to data obtained, the use of autogenous bone grafts associated with the PRP did not contribute significantly in the repair of irradiated bone. / O objetivo deste estudo foi analisar histologicamente, o reparo ósseo em lesões de tíbia previamente irradiada, após tratamento com enxerto ósseo autógeno associado ao PRP. Neste estudo, foram utilizados 12 coelhos separados em dois grupos iguais: irradiado (I) e não irradiado (II), que foram divididos em subgrupos: controle (tíbia esquerda) e PRP (tíbia direita). O grupo irradiado recebeu dose única de 15 Gy nas tíbias. Após 45 dias, nos grupos I e II, foram criadas lesões nas tíbias, com trefina de 5 mm de diâmetro. As lesões foram preenchidas com enxerto autógeno associado a PRP (grupo teste) ou não associado a PRP (grupo controle). Após quatro semanas, os animais foram sacrificados e as regiões enxertadas foram removidas, fixadas em formol tamponado, desmineralizadas em EDTA e processadas para inclusão em parafina. As imagens histológicas foram digitalizadas, utilizando objetiva de 4X, e submetidas ao processo de segmentação interativa, como preconizado por Oliveira et al. (2006). A região de matriz óssea foi denominada de Região de Interesse (ROI) e a porcentagem de matriz por área foi obtida e analisada por meio de algoritmos desenvolvidos em ambiente de programação SCILAB. Os dados foram tratados utilizando os testes Kolmogrorov Smirnov e Teste t de Student pareado e não pareado. Nos grupo irradiado e não irradiado a análise estatística não mostrou diferença significativa entre os subgrupos teste e controle. Também não foi observada diferença significativa entre os grupos irradiado e não irradiado. De acordo com os dados obtidos, a utilização de enxerto autógeno associado ao PRP não contribuiu, significativamente no reparo de lesões em osso irradiado. / Mestre em Odontologia
14

Tratamento eletroquímico e eletroquímico irradiado do corante vermelho de alizarina S / Electrochemical and irradiated electrochemical treatment of alizarin red S dye

Eduardo Marques Moreira 14 October 2011 (has links)
O vermelho de alizarina S é um corante cuja cor é função do pH. É uma antraquinona sulfonada que possui dois grupos fenólicos ligados ao mesmo anel onde se encontra o grupo sulfônico. Usualmente é comercializado sob a forma de sal monossódico, também chamado alizarinossulfonato de sódio ou simplesmente vermelho de alizarina. Esse corante pode ser sintetizado pela oxidação e hidroxilação do antraceno, seguida de sua sulfonação. Ele é largamente empregado em histoquímica, análises quantitativas e em indústrias têxtil e de couros. Na indústria de couros, esse corante vem acompanhado de grandes cargas de íon cloreto, o que é vantajoso para a aplicação de eletrodos ADE&reg no tratamento eletroquímico e fotoquímico eletro-assistido desse corante, haja vista que esses eletrodos são capazes de produzir espécies de cloro ativo altamente oxidantes, como gás cloro em pH fortemente ácido (< 2,00). Nesse trabalho foram empregados tratamentos eletroquímicos (puro e eletroquímico foto-assistido) para tratar o vermelho de alizarina S. Foram feitos estudos de densidade de corrente, concentração de cloreto de sódio, temperatura e investigação da natureza dos processos eletroquímicos irradiados. Para monitorar as degradações foram empregadas as técnicas de UV-Vis, DQO, COT, AOX e CLAE-MS. Percebeu-se que a concentração de cloreto de sódio e a corrente influenciam diretamente na velocidade de descoloração. Também foi possível notar que a regra de Van\'t Hoff equilibra-se com a regra de solubilidade dos gases em estudos de temperatura. Observou-se ainda que a irradiação aumenta muito o rendimento oxidativo das degradações, além de diminuir a quantidade de AOX gerados no produto final. Notou-se também que diminuindo a concentração de corante, a constante de velocidade de descoloração aumenta. Para monitorar os materiais eletródicos, foram empregadas as técnicas de VC, EDX e MEV. Constatou-se que eletrodos de composição Ti/Ir1-xSb1-ySn1-zO2 com baixo teor de Ir não são mecânica e eletroquimicamente resistentes, sendo necessário aumentar a concentração desse elemento e de Sb no material eletródico para incrementar a eficiência e a estabilidade. Palavras chave: Vermelho de alizarina S, ânodo dimensionalmente estável, cloreto, tratamento eletroquímico, tratamento eletroquímico irradiado / Alizarin red S is a dye whose color is a function of pH. It is a sulfonated anthraquinone which has two phenolic groups connected to the same ring where there is the sulphonic group. It is usually commercialized in the form of monossodic salt, also called sodium alizarinessulphonate or simply alizarin red. This dye can be synthesized by oxidation and hidroxilation of anthracene, followed by sulphonation reaction. It is largely used in histochemistry, quantitative analysis, textile and leather industries. In leather industry, this dye is accompanied by large quantities of chloride ions, which is advantageous for the application of DSA&reg electrodes in electrochemical or photo-assisted electrochemical treatment. This electrodes are capable of producing chlorine species, highly active oxidants such as chlorine gas in strongly acid pH (< 2.00). In this work we employed pure electrochemical and photo-assisted electrochemical treatments to degrade alizarin red S. The current density, concentration of sodium chloride, temperature parameters and the nature of irradiated electrochemical process were studied. To monitor the degradation were employed techniques of UV-Vis, COD, TOC, AOX and HPLC-MS. It was noticed that the sodium chloride concentration and the current directly influence in the rate of discoloration. It was also possible to note that the Van\'t Hoff rule is balanced with the gases solubility rule in temperature studies. It was observed that irradiation increases the efficiency of oxidation and reduce the amount of AOX generated in the final product. It was also noted that lowering the concentration of dye, the discoloration rate constant increases. To monitor the electrodic materials were used CV, SEM and EDX techniques. It was found that electrodes of Ti/Ir1-(x+y)SbxSnyO2 with low quantities of Ir are not mechanically and electrochemically resistant. Because this, it is necessary to increase the concentration of Sb and Ir elements in electrodic material to increase efficiency and stability. Key words: Alizarin red S, dimensionally stable anode, chloride, electrochemical treatment, irradiated electrochemical treatment

Page generated in 0.0356 seconds