• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 30
  • 16
  • 7
  • 1
  • 1
  • Tagged with
  • 55
  • 32
  • 23
  • 19
  • 18
  • 15
  • 15
  • 15
  • 15
  • 10
  • 10
  • 10
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Surface-initiated Polymerization and Janus Membrane Synthesis from Graphene and Poly(dopamine)

Hafner, Daniel 17 May 2021 (has links)
In dieser Arbeit wurden verschiedene Materialien durch das Pfropfen von Polymerbürsten auf Poly(dopamin) (PDA) und Graphen (G) synthetisiert. Ein besonderes Augenmerk wurde dabei auf sog. strain-engineering von Graphen und Synthese von Janus-Membranen gelegt. Die Kombination aus PDA-Oberflächenchemie und oberflächeninitiierter Cu(0)-vermittelter kontrolliert radikalischer Polymerisation (SI-CuCRP) wurde als robuste und vielseitige Methode zur Synthese von Polymerbürsten etabliert. Dabei können Schichtdicken von einigen hundert Nanometern innerhalb 1 h erreicht werden. Die Zugänglichkeit der Endgruppen bleibt erhalten, was die Synthese von Pentablockcopolymerbürsten ermöglicht. Dies stellt die bis dato höchste Blockzahl für oberflächengebundenes Copolymer dar. Zudem erlaubt die SI-CuCRP eine einfache und hocheffiziente Synthese von Polymerbürsten mit definierten Gradienten und Strukturen sowie die Funktionalisierung von natürlichen Membranen. Im zweiten Teil der Arbeit wurde diese Methode zur Funktionalisierung von Graphen mit Polymerbürsten angewendet. Aufgrund des hohen sterischen Drucks innerhalb der Bürsten, sollte die resultierende chemisch-mechanische Beanspruchung zu einer Deformation des Graphens und einem straintronic-Effekt führen. Die Bewertung und Quantifizierung der chemisch-mechanisch induzierten Belastung ist jedoch problematisch. Vermutlich führt die induzierte mechanische Spannung zum Bruch bzw. Reißen der Graphenschicht, wenn die Pfropfungsdichte und Schichtdicke der Polymerbürsten zunimmt. Diese Annahme wird durch neueste Literatur gestützt. Dennoch wurde eine ganze Reihe von Polymermodifikationen auf Graphen erhalten, um (gerichtete) Faltenbildung verschiedener Größenordnungen zu erzielen. Im Zusammenhang der Materialsynthese wurden sowohl aus PDA als auch aus Graphen Janus-Membranen, sog. Janus polymer carpets, hergestellt. Hierzu wurde entweder sequentieller Transfer freistehender Polymerteppiche oder einseitige, sequentielle Polymerisation auf Graphen genutzt. Auf diesem Weg wurden Janus-Membranen hergestellt, die hydrophob/hydrophil, nicht-sensitiv/T sensitiv oder nicht sensitiv/pH sensitiv sind oder eine Polymerbürsten/Flaschenbürsten-Architektur besitzen. Diese kann allerdings Reihe auf einfache Weise erweitert werden. Alle hergestellten Janus polymer carpets weisen typischerweise eine Größe von ca. 1 cm² auf. Unter Berücksichtigung ihrer Gesamtdicken, die im Bereich von max. einigen hundert Nanometern liegen, betragen die Aspektverhältnisse zwischen 10000 und 100000. In Kombination mit der strukturellen Vielfalt von Polymerbürsten bieten die vorgestellten Methoden einen einzigartigen Weg zu einer ganzen Palette neuartiger 2D-Materialien mit einstellbaren Eigenschaften. Das hervorragende Faltverhalten von strukturierten Janus polymer carpets macht sie besonders interessant für gerichteten Transport und Bewegung oder kontrollierte Verformung.
52

Synthesis and controlled radical polymerization of multifunctional monomers

Yin, Meizhen 08 June 2004 (has links)
Multifunctional monomers on the basis of acryl- and methacryl derivatives were synthesized and different protective groups were used. After polymerization the protective groups were removed by different methods. Various initiators for the NMP of the monomers were synthesized and the reaction conditions were optimized. The results showed that NMP was not a suitable method for multifunctional acryl- and methacryl derivatives to achieve well-defined homopolymers, although it was successful for control of polymerization of styrene and block copolymerization of multifunctional acryl- and methacryl derivatives with alkoxyamine terminated polystyrene. The ATRP of multifunctional acrylates and methacrylates has been successfully performed, as well as the block copolymerization of multifunctional acrylates and methacrylates. Relatively low polydispersities of the corresponding polymers (PD=1.18-1.36) and reasonably high rates of polymerization could be achieved when Me6TREN and PMDETA were used as ligands. However, the ATRP of multifunctional acrylamides and methacrylamides failed. The RAFT-polymerization of styrene, acrylamide and acrylate using BDTB as a CTA and AIBN as an initiator afforded polymers with narrow molecular weight distribution (PD=1.13-1.26). A kinetic investigation and the further synthesis of block copolymers using dithioester-terminated homopolymers as macroCTAs showed that the RAFT polymerization of acrylamide M9b proceeded in a living manner. However, BDTB does not control the reaction of methacrylic monomers, such as methacrylates and methacrylamides. The bulk phase behavior of the block copolymers were examined by means of DSC and the surface behaviors of block copolymers as thin layers were examined with AFM. Two-phase transitions in the block copolymers were observed clearly by DSC, indicative of the appearance of phase separations, which were seen in an AFM image. In conclusion, multifunctional acryl- and methacryl derivatives failed to achieve well-defined homopolymers by NMP. However, this method was successful for block copolymerization of multifunctional acryl- and methacryl derivatives with alkoxyamine terminated polystyrene. Multifunctional acrylates and methacrylates were successfully homopolymerized and block copolymerized by ATRP. Multifunctional acrylates and acrylamides were suitable for homopolymerization and block copolymerization by the RAFT process. Thus far, it is difficult to homopolymerize multifunctional methacrylamides in controlled way.
53

Omega‑3 fatty acids in bipolar patients with a low omega‑3 index and reduced heart rate variability: the “BIPO‑3” trial

Berger, Michael, Seemüller, Florian, Voggt, Alessandra, Obermeier, Michael, Kirchberg, Franca, Löw, Anja, Riedel, Michael, von Schacky, Clemens, Severus, Emanuel 22 February 2024 (has links)
Background: Research suggests that a low omega-3 index may contribute to the low heart rate variability and the increased risk of cardiovascular morbidity and mortality in bipolar disorders. However, so far, no intervention trial with EPA and DHA has been conducted in bipolar patients attempting to increase their heart rate variability. - Methods: 119 patients with bipolar disorder according to DSM-IV were screened, with 55 euthymic bipolar patients—owing to inclusion criteria (e.g. low omega-3 index (< 6%), SDNN < 60 ms.)—being enrolled in a randomized, double-blind, 12-week parallel study design with omega-3 fatty acids (4 capsules of 530 mg EPA, 150 mg DHA) or corn oil as a placebo, in addition to usual treatment. Heart rate variability as well as the omega-3 index were measured at baseline and at the endpoint of the study. - Results: A total of 42 patients (omega-3: n = 23, corn oil: n = 19) successfully completed the study after 12 weeks. There was a significant increase in the omega-3 index (value at endpoint minus value at baseline) in the omega-3 group compared to the corn oil group (p < 0.0001). However, there was no significant difference in the change of the SDNN (value at endpoint minus value at baseline) between the treatment groups (p = 0.22). In addition, no correlation between changes in SDNN and change in the omega-3 index could be detected in the omega-3 group (correlation coefficient = 0.02, p = 0.94) or the corn oil group (correlation coefficient = − 0.11, p = 0.91). Similarly, no significant differences between corn oil and omega-3 group regarding the change of LF (p = 0.19), HF (p = 0.34) and LF/HF ratio (p = 0.84) could be demonstrated. - Conclusions: In our randomized, controlled intervention trial in euthymic bipolar patients with a low omega-3 index and reduced heart rate variability no significant effect of omega-3 fatty acids on SDNN or frequency-domain measures HF, LF and LF/HF ratio could be detected. Possible reasons include, among others, the effect of psychotropic medication present in our trial and/or the genetics of bipolar disorder itself. Further research is needed to test these hypotheses.
54

Design of the DAVOS Study: Diabetes Smartphone App, a Fully Automatic Transmission of Data From the Blood Glucose Meter and Insulin Pens Using Wireless Technology to Enhance Diabetes Self-Management - A Study Protocol for a Randomized Controlled Trial

Grosser, Franziska, Herrmann, Sandra, Bretschneider, Maxi, Timpel, Patrick, Schildt, Janko, Bentrup, Markus, Schwarz, Peter E. H. 04 April 2024 (has links)
Background: In the treatment of diabetes mellitus, the challenge is to integrate adequate self-management into clinical care. Customization including goal setting, monitoring, and feedback could be achieved through digitization. Digital linking between different devices could simplify and promote self-management. The aim of this study is to evaluate the outcome of diabetes treatment assisted by a digital health application compared with standard diabetes therapy. - Methods: The DAVOS study is a 6-month-period prospective, multicentric, randomized controlled trial. In total, 154 diabetes patients (age ≥18; treated with insulin) will be recruited and randomized into control group or intervention group. Both groups will receive standard diabetes care. The intervention group will additionally use a diabetes app. HbA1c value will be monitored on three separate defined visits. Primary endpoint is the overall reduction of HbA1c value. Secondary endpoints (eg, usability of the app) will be determined through patient-reported outcome questionnaires. - Discussion: Through enhanced interaction of health care professionals, providers of the app, and patients, the study aims to demonstrate improvement in the self-management of diabetes. As part of the closure management, all patients will be invited to use the examined application after completion of the study. The DAVOS study will be conducted in accordance with the valid version of the present study protocol and the internationally recognized International Conference on Harmonization–Good Clinical Practice (ICH-GCP) Guidelines. Special attention will be paid to European, national, and regional requirements for the approval, provision, and use of medical devices. The study was registered in the German Register of Clinical Trials (DRKS) with number DRKS00025996.
55

Kontrollierte natürliche Lüftung in Büro- und Verwaltungsgebäuden: Ein Beitrag zur Steigerung von Energieeffizienz und Nutzerbehaglichkeit

Scheuring, Leonie 26 August 2022 (has links)
Es ist ein politisch erklärtes Ziel, den Ausstoß von klimaschädlichen Treibhausgasen weltweit zu verringern. Eine wesentliche Stellschraube im Gebiet des Bauwesens stellt hierbei die Einsparung von Energien zur Raumkonditionierung dar. Diese wird unter anderem über das Lüftungskonzept beeinflusst. Die Belüftung von Gebäuden ist zwingend notwendig, um die Emissionen der Baustoffe und die der Menschen, beispielsweise ihren CO2-Ausstoß über die Atmung, abzuführen und der Schimmelbildung vorzubeugen. Erfolgt die Belüftung über öffenbare Fenster – natürliche Lüftung – wird so allerdings energetisch aufwändig temperierte Raumluft mit untemperierter Außenluft ausgetauscht. Daraus können Wärmeverluste und thermisches Unbehagen resultieren. Energieeffiziente Technologien sind ventilatorgestützte Lüftungssysteme mit Wärmerückgewinnung. Doch nicht für alle Gebäudekonzepte und Nutzer stellen diese Lüftungskonzepte einen hohen Nutzerkomfort dar. Korrelationen zwischen Gebäuden mit ventilatorgestützten Lüftungsystemen und dem Sick-Building-Syndrom sind in der Literatur beschrieben, während hier für natürliche Lüftungskonzepte keine Korrelation besteht. Stattdessen wird in Nutzerbefragungen der natürlichen Lüftung eine hohe Akzeptanz zugeschrieben. Mit elektrisch angetriebenen Fenstern kann die natürliche Lüftung nutzerunabhängig gesteuert und so Wärmeverluste und thermisches Unbehagen kontrolliert werden. Bisher sind die Auslegungen solcher kontrollierten natürlichen Lüftungskonzepte noch sehr planungsintensiv. Das Ziel der Arbeit ist es, für Büro- und Verwaltungsgebäude Öffnungs- und Schließsignale einer kontrollierten natürlichen Lüftung zu geben. Diese zeichnen sich darüber aus, dass sie ein gesundes Raumklima, eine hohe Nutzerbehaglichkeit und Energieeffizienz über den Jahresverlauf schaffen und auf ihre Robustheit gegenüber Änderungen von Gebäuderandbedingungen überprüft sind. Für das Ziel wird ein über CO2- und Temperatursensoren gesteuertes Fenstersystem mittels dynamisch thermischer Gebäudesimulationen in vier Varianten von Schließsignalen auf thermische Behaglichkeit und Energiebedarf untersucht. Die Grundlage dazu stellt die bezüglich Entwurf, Konstruktion und Nutzung allgemeingültige Entwicklung eines Büroraums dar. Der Büroraum wird im Simulationsmodell abgebildet und in Realität errichtet. Die Kombination von Simulationsmodell und realem, als experimentellem Teststand ausgeführtem Büroraum ermöglicht verifizierte Ergebnisse. So werden vier Berechnungsmodelle für Luftvolumenströme von Fenstern über den Teststand verifiziert. Dazu dienen Luftwechselmessungen nach der Konstantinjektionsmethode an 173 Fensteröffnungen für fünf Außentemperatur- und elf Windgeschwindigkeitsbereiche. Das Berechnungsmodell nach DIN EN 16798-7 zeigt sich als realitätsnah. Da dieses Berechnungsmodell nicht im Gebäudesimulationsprogramm implementiert ist, wird eine Methode zur Implementierung entwickelt. Über das entwickelte Simulationsmodell zeigt sich, dass eine kombinierte CO2- und temperaturgesteuerte kontrollierte natürliche Lüftung nur zweimal im Jahr ihre Grenzwerte zur Fensteröffnung und -schließung variieren muss, um ganzjährig eine hohe Energieeffizienz und Nutzerbehaglichkeit zu schaffen. Die Schließsignale des sensorgesteuerten Fenstersystems werden in eine Zeitsteuerung überführt. Es zeigt sich, dass für die kühlen Monate jede Öffnung mit identischer Dauer angesetzt werden darf. In wärmeren Monaten muss die Öffnungsdauer in Abhängigkeit der Außentemperatur angepasst werden, so dass eine Zeitsteuerung mit einer Außentemperaturmessung gekoppelt werden muss. Die Ergebnisse zeigen, dass über eine Variation der Schließsignale einer kontrollierten natürlichen Lüftung die Energieeffizienz und die thermische Behaglichkeit wesentlich gesteigert werden und dass selbst bei geringen Windgeschwindigkeiten und Temperaturdifferenzen die Raumluftqualität stets gewährleistet ist. Für nahezu alle Standorte in Deutschland kann die kontrollierte natürliche Lüftung so den Kühlbedarf der untersuchten Büroräume eliminieren, ohne in einer sommerlichen Überhitzung der Räume zu resultieren. Die entwickelten und bezüglich Raumluftqualität und thermischer Behaglichkeit charakterisierten Sensor- und Zeitsteuerungen tragen dazu bei, die kontrollierte natürliche Lüftung als wartungsarme, technikreduzierte Alternative zu der ventilatorgestützten Lüftung zu etablieren.:1 Einleitung 2 Natürliche Lüftung 3 Kontrollmöglichkeiten der natürlichen Lüftung 4 Entwicklung der Untersuchungsmodelle 5 Voruntersuchungen 6 Sensorsteuerung für den Basisraum 7 Zeitsteuerung für den Basisraum 8 Übertragung auf unterschiedliche Gebäuderandbedingungen 9 Diskussion und Empfehlungen 10 Zusammenfassung und Ausblick 11 Literatur 12 Abbildungsnachweis 13 Bezeichnungen 14 Anhang / It is a politically declared goal to reduce the emission of climate-damaging greenhouse gases worldwide. To support this goal by the building industry a key driver is the saving of energy for room conditioning. Among other factors, this is influenced by the ventilation concept. Also the ventilation of buildings is absolutely necessary in order to remove the emissions of the building materials and those of the people, for example their CO2 emissions through breathing as well as to prevent mould. However, if ventilation is carried out via openable windows - natural ventilation - then energetically expensive tempered room air is exchanged with cold outside air. This could result in heat loss and thermal discomfort. Mechanical ventilation systems with heat recovery are energy-efficient technologies. However, these ventilation concepts do not represent a high level of user comfort for all building concepts and users. Correlations between buildings with mechanical ventilation systems and sick building syndrome are described in the literature, while there is no such correlation for natural ventilation concepts. Instead, a high level of acceptance is attributed to it in user surveys. With electrically driven and controlled windows, natural ventilation can be controlled independently from the user, thus minimizing heat loss and thermal discomfort. So far, the design of such controlled natural ventilation concepts is still very planning-intensive. The aim of this work is to provide opening and closing signals for controlled natural ventilation in office buildings. These are characterized for their capability to create a high indoor air quality, high user comfort and high energy efficiency over the course of the year and are tested for their robustness against changes in building characteristics. To achieve this goal, a window system controlled by CO2 and temperature sensors is examined for its impact on thermal comfort and energy demand by means of building simulation tools with four variants of closing signals. As a basis for this examination an office room is utilized that conforms to the current standards in terms of design, construction and use. The office space is transferred to a simulation model and constructed in reality. The combination of the simulation model and the real office space, which is designed as an experimental test rig, enables verified results. Thus, four calculation models for air flow volumes of windows are verified via the test rig. Air exchange measurements according to the constant injection method on 173 window openings for five outdoor temperature and eleven wind speed ranges are used for this purpose. The calculation model according to DIN EN 16798-7 proves to be close to reality. Since this calculation model is not implemented in the building simulation program, a method for its implementation is developed. Using the developed simulation model, it is shown that a combined CO2- and temperature-controlled natural ventilation creates a high energy efficiency and user comfort throughout the year by varying its limit values for window opening and closing only twice a year. The closing signals of the sensor controlled window system are transferred to a time control system. It turns out that for the cold months, each opening could be set to the same opening time. In warmer months, the opening time must be adjusted depending on the outside temperature. Thus, a time control should be coupled with an outside air temperature measurement. The results show that by varying the closing signals of a controlled natural ventilation system, the energy efficiency and thermal comfort is significantly increased and that a high indoor air quality is always guaranteed even at low wind speeds and low temperature differences. For almost all locations in Germany, controlled natural ventilation can thus eliminate the cooling requirements in the office spaces studied without overheating in the summer. The developed sensor and time control systems are characterized by high indoor air quality and good thermal comfort. Thus, these systems are a contribution to promote controlled natural ventilation as a low-maintenance and technically reduced alternative to mechanical ventilation.:1 Einleitung 2 Natürliche Lüftung 3 Kontrollmöglichkeiten der natürlichen Lüftung 4 Entwicklung der Untersuchungsmodelle 5 Voruntersuchungen 6 Sensorsteuerung für den Basisraum 7 Zeitsteuerung für den Basisraum 8 Übertragung auf unterschiedliche Gebäuderandbedingungen 9 Diskussion und Empfehlungen 10 Zusammenfassung und Ausblick 11 Literatur 12 Abbildungsnachweis 13 Bezeichnungen 14 Anhang

Page generated in 0.0516 seconds