• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Implementering av en PSS i Trängslets kraftstation

Ilis, Lars January 2013 (has links)
The purpose of this master thesis is to implement and validate a Power System Stabilizer (PSS) to a generator at Trängslet hydropower station in Dalarna, Sweden. Problems with local rotor oscillations can occur at the hydropower station when power is transferred on a new power line (130 kV) from Northern to Southern part of Dalarna. To ensure good operation properties on this power line Fortum Generation AB and Fortum Distribution AB wants to activate a PSS on a generator. There have been investigations in which situations and what equipment that contributes to rotor oscillations. When this is known the PSS is tuned to damp these oscillations by choosing a good set of parameters. The most important parameters for good performance are to choose amount of gain and phase compensation. The chosen set of parameters are verified with a test in the power station to ensure that the task is completed. Test results shows that the magnitude of the first swing in rotor oscillation is almost the double than what PSS/E shows, but good correlation five seconds after initialization of the disturbance. The inherent dampening performance of the generator is much better in reality than in simulation. The chosen set of parameters contributes to rotor oscillation dampening in a magnitude approximately equal to simulation results in PSS/E, why the conclusion has been made that the implementation of the PSS is successful. There has also been made simulations with different power outputs and amount of generators synchronized whose results shows that damping is greatly increased with the chosen PSS.
2

Avledning av öringsmolt (<em>Salmo trutta</em>) från turbinintag / Diversion of trout smolts (<em>Salmo trutta)</em> from turbine intakes

Engqvist, Thérèse January 2009 (has links)
<p>Vattenkraftstationer, med dammar och turbiner, utgör hinder för nedströmsvandrande smolt. Syftet med denna studie var att undersöka turbindödligheten för öringsmolt (<em>Salmo trutta)</em> vid två kraftstationer, de befintliga ytlänsarnas avledningseffekt och om effekten kunde förstärkas genom mörkläggning i form av övertäckning av kraftkanalen med en presenning vid turbinintaget. Utöver detta var avsikten även att undersöka om det fanns något samband mellan smoltgrad och smoltens förmåga att förflytta sig mot havet. I Emån i Småland fångades 46 öringsmolt som radiomärktes och sattes ut vid två kraftstationer och pejlades dagligen i sex veckor. Det var en större dödlighet vid den övre stationen än vid den nedre. Ytlänsen vid den nedre stationen hade en klart avledande effekt, men inte ytlänsen vid den övre stationen. Samtliga smolt som valde passage via isutskovet, gjorde det när kraftkanalen vid turbinintaget var övertäckt med presenning (d.v.s. ljusintensiteten minskades kraftigt). Det gick inte att påvisa någon skillnad mellan låg och hög smoltgrad eller tidig och sen utsättning för fördröjning vid den ena kraftstationen, inte heller för förflyttning efter de två kraftstationerna.</p> / <p>Hydropower plants, with dams and turbines, form obstacles to smolts migrating downstream. The purpose of this study was to investigate turbine-induced mortality of brown trout (<em>Salmo trutta</em>) smolts at two power plants, guidance efficiency of existing diverters and whether the effect was enhanced by reducing light levels at the turbine intake by covering the power plant channel with an opaque tarpaulin. Furthermore, the aim was to investigate whether there was a relationship between smolt status and the smolts’ ability to move towards the sea. In the River Emån in Småland 46 trout smolts were caught, radio-tagged, released at two power plants and tracked daily for six weeks. There was a higher mortality at the upper power plant than at the lower one. The diverter at the lower power plant had a statistically significant guiding effect, but the diverter at the upper power plant did not. All of the smolts that chose passage through the trash gate did so when the power channel was covered with tarpaulin (i.e. light levels were greatly reduced). There was no evidence that smolt status or release date would affect passage times at the upper station, nor did smolt status affect swimming speeds downstream of the two power stations.</p> / Cost-Benefit Analysis of River Regulation
3

Avledning av öringsmolt (Salmo trutta) från turbinintag / Diversion of trout smolts (Salmo trutta) from turbine intakes

Engqvist, Thérèse January 2009 (has links)
Vattenkraftstationer, med dammar och turbiner, utgör hinder för nedströmsvandrande smolt. Syftet med denna studie var att undersöka turbindödligheten för öringsmolt (Salmo trutta) vid två kraftstationer, de befintliga ytlänsarnas avledningseffekt och om effekten kunde förstärkas genom mörkläggning i form av övertäckning av kraftkanalen med en presenning vid turbinintaget. Utöver detta var avsikten även att undersöka om det fanns något samband mellan smoltgrad och smoltens förmåga att förflytta sig mot havet. I Emån i Småland fångades 46 öringsmolt som radiomärktes och sattes ut vid två kraftstationer och pejlades dagligen i sex veckor. Det var en större dödlighet vid den övre stationen än vid den nedre. Ytlänsen vid den nedre stationen hade en klart avledande effekt, men inte ytlänsen vid den övre stationen. Samtliga smolt som valde passage via isutskovet, gjorde det när kraftkanalen vid turbinintaget var övertäckt med presenning (d.v.s. ljusintensiteten minskades kraftigt). Det gick inte att påvisa någon skillnad mellan låg och hög smoltgrad eller tidig och sen utsättning för fördröjning vid den ena kraftstationen, inte heller för förflyttning efter de två kraftstationerna. / Hydropower plants, with dams and turbines, form obstacles to smolts migrating downstream. The purpose of this study was to investigate turbine-induced mortality of brown trout (Salmo trutta) smolts at two power plants, guidance efficiency of existing diverters and whether the effect was enhanced by reducing light levels at the turbine intake by covering the power plant channel with an opaque tarpaulin. Furthermore, the aim was to investigate whether there was a relationship between smolt status and the smolts’ ability to move towards the sea. In the River Emån in Småland 46 trout smolts were caught, radio-tagged, released at two power plants and tracked daily for six weeks. There was a higher mortality at the upper power plant than at the lower one. The diverter at the lower power plant had a statistically significant guiding effect, but the diverter at the upper power plant did not. All of the smolts that chose passage through the trash gate did so when the power channel was covered with tarpaulin (i.e. light levels were greatly reduced). There was no evidence that smolt status or release date would affect passage times at the upper station, nor did smolt status affect swimming speeds downstream of the two power stations. / Cost-Benefit Analysis of River Regulation

Page generated in 0.135 seconds