1

Análise experimental da punção em lajes de concreto armado e protendido / Experimental punching shear analysis of reinforced and prestressed concrete slabs

Melges, José Luiz Pinheiro 29 March 2001 (has links)
As lajes lisas podem oferecer diversas vantagens quando comparadas ao sistema de lajes, vigas e pilares, sendo, em muitos casos, mais econômicas. O uso da protensão pode oferecer outras vantagens, tais como um melhor controle da fissuração e dos deslocamentos transversais da laje. Como a punção é um dos pontos fracos das lajes lisas protendidas, face à grande esbeltez destas lajes, apresentam-se resultados experimentais de ligações laje-pilar interno, com carregamento concêntrico, com e sem armadura de punção (conectores tipo-pino), com e sem protensão por pós-tração (cabos não aderentes). Os principais aspectos analisados foram as influências da armadura de punção e da protensão na resistência da ligação laje-pilar. Fez-se também uma análise envolvendo a previsão da resistência da ligação, dada por algumas normas e códigos. Observa-se que, de um modo aproximado, a armadura de punção eleva significativamente a resistência do modelo à punção, seja ele de concreto armado ou protendido. Observa-se ainda que, embora diminuindo a taxa de armadura dos modelos de concreto armado, para que se introduzissem as cordoalhas de protensão, os valores experimentais obtidos mostram que a presença da protensão aumentou a resistência da ligação. De um modo geral, a melhor norma que reflete o comportamento da ligação lajepilar é a Revisão da NB-1 (2000). Com relação aos modelos protendidos, o ACI poderia ter tido um bom desempenho, caso não houvesse uma restrição tão rígida com relação ao uso de armaduras de punção / The use of flat plates may offer some economical and aesthetic benefits when compared with other structural systems. The use of post-tensioned slabs may offer other advantages, as a better crack and deflection control and a thinner slab for the same span and load conditions. This work presents some experimental results and conclusions about the punching shear failure, as it is a critical problem for flat plate structures, post-tensioned or not. The main aspects analyzed are the influence of the shear reinforcement (studs) and of the post-tensioning with unbonded tendons on a slab – internal column connection strength. A comparison between experimental results and those given by some standards is presented. This comparison aims to verify if the codes accurately predict the punching shear strength of the connection. It can be noted that, in an specific comparison, the studs enhance the punching shear strength of the slab-column connection. In spite of the use of less flexural reinforcement in the post-tensioned models, the punching shear strength of the connection had a higher value when compared with the reinforced ones. This fact is due to the presence of the prestressed strands
2

Análise experimental da punção em lajes de concreto armado e protendido / Experimental punching shear analysis of reinforced and prestressed concrete slabs

José Luiz Pinheiro Melges 29 March 2001 (has links)
As lajes lisas podem oferecer diversas vantagens quando comparadas ao sistema de lajes, vigas e pilares, sendo, em muitos casos, mais econômicas. O uso da protensão pode oferecer outras vantagens, tais como um melhor controle da fissuração e dos deslocamentos transversais da laje. Como a punção é um dos pontos fracos das lajes lisas protendidas, face à grande esbeltez destas lajes, apresentam-se resultados experimentais de ligações laje-pilar interno, com carregamento concêntrico, com e sem armadura de punção (conectores tipo-pino), com e sem protensão por pós-tração (cabos não aderentes). Os principais aspectos analisados foram as influências da armadura de punção e da protensão na resistência da ligação laje-pilar. Fez-se também uma análise envolvendo a previsão da resistência da ligação, dada por algumas normas e códigos. Observa-se que, de um modo aproximado, a armadura de punção eleva significativamente a resistência do modelo à punção, seja ele de concreto armado ou protendido. Observa-se ainda que, embora diminuindo a taxa de armadura dos modelos de concreto armado, para que se introduzissem as cordoalhas de protensão, os valores experimentais obtidos mostram que a presença da protensão aumentou a resistência da ligação. De um modo geral, a melhor norma que reflete o comportamento da ligação lajepilar é a Revisão da NB-1 (2000). Com relação aos modelos protendidos, o ACI poderia ter tido um bom desempenho, caso não houvesse uma restrição tão rígida com relação ao uso de armaduras de punção / The use of flat plates may offer some economical and aesthetic benefits when compared with other structural systems. The use of post-tensioned slabs may offer other advantages, as a better crack and deflection control and a thinner slab for the same span and load conditions. This work presents some experimental results and conclusions about the punching shear failure, as it is a critical problem for flat plate structures, post-tensioned or not. The main aspects analyzed are the influence of the shear reinforcement (studs) and of the post-tensioning with unbonded tendons on a slab – internal column connection strength. A comparison between experimental results and those given by some standards is presented. This comparison aims to verify if the codes accurately predict the punching shear strength of the connection. It can be noted that, in an specific comparison, the studs enhance the punching shear strength of the slab-column connection. In spite of the use of less flexural reinforcement in the post-tensioned models, the punching shear strength of the connection had a higher value when compared with the reinforced ones. This fact is due to the presence of the prestressed strands
3

Análise do efeito da retangularidade dos pilares nos critérios normativos de dimensionamento à punção em lajes lisas de concreto armado / Analysis of the effect of rectangularity rate of the columns in normative criteria for sizing punching in reinforced concrete flat slabs

PAIVA, Odilson da Silva de 22 October 2013 (has links)
Submitted by Cássio da Cruz Nogueira (cassionogueirakk@gmail.com) on 2017-03-16T13:05:15Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-20T16:05:13Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) / Made available in DSpace on 2017-03-20T16:05:13Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_AnaliseEfeitoRetangularidade.pdf: 2760909 bytes, checksum: f7553da9a0e039bc587df51a11724a63 (MD5) Previous issue date: 2013-10-22 / O sistema com lajes lisas que não dependem de vigamento apresenta sua resistência limitada pela resistência à punção, visto que a região da ligação laje-pilar é critica devido às cargas concentradas em torno dos pilares. A geometria dos pilares é um dos fatores de influência na distribuição de tensões da região de ligação laje-pilar afetando por sua vez no dimensionamento à punção de lajes lisas. Neste estudo foi realizada uma profunda coleta de dados que visa reunir em um único trabalho a maior quantidade possível de lajes englobando os maiores nomes no estudo de punção, nacionais e internacionais, apresentando um total de 131 lajes. Foi feita uma comparação entre os principais códigos normativos usados atualmente, Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) e CEB-FIP (2010). Os resultados experimentais foram confrontados com os obtidos teoricamente levando em consideração os efeitos do índice de retângularidade em lajes lisas de concreto armado sem armaduras de cisalhamento verificando a adequação, confiabilidade de cada recomendação, analisando as particularidades das regras e diretrizes de cada critério normativo. / The system with flat slabs that do not depend on framework of beam has limited resistance by the resistance to punching shear, since the region of the slab-column is critical due to concentrated loads around the columns. The geometry of the columns is one of the factors influencing the distribution of stresses in the region of slab-column connection affecting turn in sizing the punching shear in the flat slabs. In this study we performed a thorough data collection that aims to collect into a single job the greatest possible amount of slabs covering the biggest names in the study of national and international punch, featuring a total of 131 slabs. A comparison was made between the main normative codes currently used Eurocode 2 (2004), NBR 6118 (2007), ACI 318 (2008) and CEB-FIP (2010). The experimental results were compared with those obtained theoretically taking into account the effects of retangularidade rate index in flat slabs of reinforced concrete, without punching shear reinforcement checking the adequacy, trustworthiness of each recommendation, analyzing the particularities of the rules and guidelines of each normative criterion.
4

Punção em lajes lisas de concreto armado com furo adjacente ao pilar e transferência de momento / Punching Shear In Reinforced Flat Slabs with Hole Adjacent to the Column and Moment Transfer

OLIVEIRA, Diorgenes Carvalho de 17 June 2011 (has links)
Made available in DSpace on 2014-07-29T15:03:34Z (GMT). No. of bitstreams: 1 Dissertacao Diorgenes C de Oliveira.pdf: 4985818 bytes, checksum: 3bb65a23267322ba684300f2b7486ab1 (MD5) Previous issue date: 2011-06-17 / The structural behavior and the ultimate punching shear resistance of internal reinforced concrete flat slab-column connections, with one hole adjacent to the column, with or without flexural moment transfer of the slab to the column was investigated. Main variables were: the existence whether or not hole, flexural reinforcement layout and ratio, the direction and sense of the moment transferred and the eccentricity of the load (M (moment transferred to column) / V (shear)) ratio at the connection - 0,50 m or 0,25 m. Seven internal slab-column joining were tested and ultimate loads, cracking, deflections, concrete and reinforcement strains were analyzed. The existence of hole adjacent to the smaller column dimension, the hole dimension, flexural reinforcement rate and placing, the variation of relation Mu/Vu in function of the load, and, than, of eccentricity of the load, influenced the slabs behavior and rupture load. These influences were quantified. Test results were compared with the estimations from CEB-FIP/MC1990, EC2/2004, ACI-318:2005 and NBR 6118:2003. ACI and EC2 presented most conservative estimates, although have presented some non conservative estimates. Brazilian NBR, even though being partly based in EC2, presented smaller conservative estimates and more non conservative estimates. A modification on all codes is proposed for taking in account the moment caused by the eccentricity at the critical perimeter for slabs with holes. / São investigados o comportamento estrutural e a resistência última à punção de ligações laje-pilar de regiões internas das lajes lisas, com um furo adjacente ao pilar, e com ou sem transferência de momento fletor da laje ao pilar. As principais variáveis foram: a existência ou não de furo, a taxa e a distribuição da armadura de flexão, a direção e o sentido do momento transferido e a excentricidade de carga (relação M(momento transferido ao pilar)/V(força cortante)) na ligação, igual a 0,50 m ou 0,25 m. Foram ensaiadas 7 (sete) ligações internas laje-pilar e analisados os resultados das cargas últimas, fissuração, deslocamento vertical, deformações das armaduras de flexão e do concreto. A existência de furo adjacente ao menor lado do pilar, a taxa e a distribuição da armadura de flexão, a variação da relação Mu/Vu em função do carregamento, e, por conseguinte, da excentricidade, influenciaram o comportamento e a carga de ruptura das lajes. Essas influências foram quantificadas. Os resultados experimentais foram comparados com os estimados pelas normas: CEB-FIP/MC1990, EC2/2004, ACI-318:2005 e NBR 6118:2003. O ACI e o EC2 apresentaram estimativas mais conservadoras, embora tenham apresentado algumas estimativas contra a segurança. A NBR 6118:2003, apesar de baseada em parte no EC2, apresentou estimativas menos conservadoras e com um número maior de estimativas contra a segurança. Recomenda-se que todas as normas passem a considerar o momento causado pela excentricidade do perímetro crítico em lajes com furos e, neste sentido, foram apresentadas propostas de modificações para todas as normas estudadas.
5

Análise experimental de lajes lisas unidirecionais de concreto armado ao puncionamento simétrico ou assimétrico / Experimental unidirectional smooth flagstone analysis of reinforced concrete to the symmetrical or anti-symmetrical punching

FERREIRA, Maurício de Pina 02 March 2006 (has links)
Made available in DSpace on 2011-03-23T21:19:40Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:40Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:298 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Punching is normally a critical case in the design of reinforced concrete flat slabs. According to many design codes, punching develops in a more unfavorable way in cases where the load is asymmetrically applied, due to unbalanced bending moments at slab-column connections. In order to evaluate the normative prescriptions in these cases, 12 reinforced concrete oneway flat slabs ( c f ' between 36 and 58 MPa) were submitted to symmetric or asymmetric punching. The slabs dimensions were (1.800 x 1.800 x 110) mm with the load being applied through a metallic plate simulating a square column with (85 x 85 x 50) mm. This research had as variables, in addiction to the load position, the reinforcement rate in transversal direction, in order to evaluate their influence in the punching ultimate resistance of one-way slabs. Results for vertical deflections, concrete surface and flexural reinforcement strains, cracking pattern, observed ultimate loads and failure modes are presented and analyzed. Also were analyzed the estimates of 6 design codes, with 3 European and 1 North-American, beyond the versions from 1978 and 2003 of the Brazilian structural concrete design code. A numerical analysis using the Finite Elements Method to simulate the slabs behavior is presented and its results are compared to the experimentally observed ones. The results showed that, unlike the normative previsions, punching resistance doesnt reduce linearly with the increments in the loads eccentricities, with the flexural effects significantly influencing the ultimate punching resistance. Even in one-way slabs, the transversal reinforcement rate showed significant influence on the slabs force distribution, interfering in the punching resistance. / O puncionamento é normalmente uma situação crítica no projeto de lajes lisas de concreto armado. Segundo várias normas de projeto, o puncionamento se desenvolve de maneira ainda mais desfavorável nos casos onde o carregamento atua de forma assimétrica, graças a momentos desbalanceados na ligação laje-pilar. Visando avaliar as recomendações normativas para estas situações, foram ensaiadas 12 lajes lisas unidirecionais de concreto armado ( c f ' entre 36 e 58 MPa) submetidas a puncionamento simétrico ou assimétrico. As lajes apresentavam dimensões de (1.800 x 1.800 x 110) mm com carregamento sendo aplicado através de uma chapa metálica simulando um pilar quadrado com (85 x 85 x 50) mm. O trabalho teve como variáveis, além da posição de carregamento, a taxa de armadura na direção transversal, objetivando avaliar a influência destas armaduras na resistência última ao puncionamento de lajes lisas unidirecionais. São apresentados e analisados os resultados dos deslocamentos verticais, deformações na superfície de concreto e nas armaduras de flexão, mapas de fissuração, cargas últimas e modos de ruptura observados. Apresentam-se ainda os resultados da avaliação das recomendações de 6 normas de projeto, sendo 3 européias e 1 norte americana, além das versões de 1978 e 2003 da norma brasileira para projeto de estruturas de concreto. Foi realizada também uma análise numérica utilizando o Método dos Elementos Finitos para idealizar o comportamento das lajes, comparando-se os resultados desta análise elástica com aqueles verificados experimentalmente. Os resultados indicaram que, ao contrário do que as normas prescrevem, a resistência ao puncionamento não diminui de forma linear com o aumento da excentricidade do carregamento, com a flexão influenciando significativamente na resistência última ao puncionamento. Os resultados indicam também que, mesmo em lajes unidirecionais, a taxa de armadura transversal apresenta influência significativa na distribuição dos esforços na laje, interferindo na resistência à punção.
6

Análise experimental de lajes lisas nervuradas de concreto armado com armadura de cisalhamento / Experimental nervuradas smooth flagstone analysis of reinforcement concrete with shear armor

SOUZA, Shirley do Socorro Melo de 11 January 2007 (has links)
Made available in DSpace on 2011-03-23T21:19:40Z (GMT). No. of bitstreams: 0 / Item created via OAI harvest from source: http://www.bdtd.ufpa.br/tde_oai/oai2.php on 2011-03-23T21:19:40Z (GMT). Item's OAI Record identifier: oai:bdtd.ufpa.br:300 / Two-way waffle flat slabs are structural elements of reinforced concrete supported directly on columns, under bending moments over the two directions, they improve the speed of the execution and save moulds and concrete and, consequently, labor. This work seeks to contribute for the study of the behavior of this kind of slab, as the shear resistance of the ribs and the punching in the solid area, through tests of 8 two-way reinforced concrete waffle flat slabs. Comparative analyses between the experimental results and estimated by national and international design codes had been carried out. The slabs were square, with 1.800 mm of side and total height of 140 mm. The cross section of the slabs was formed by ribs with 50 mm of width for the base and 100 mm for the upper base and the spaces between the ribs had been filled with EPS blocks (expanded polystyrene). The main variables considered were the type of shear reinforcement in the ribs (trusses, closed vertical stirrup and 45 inclined stirrup) and the use of 45 inclined stirrup as shear reinforcement in the solid region. They were presented and analyzed the results observed for the vertical displacements, deformation in the flexural and shear reinforcement, and the propagation of cracks. The values observed for failure loads were compared with the estimated ones. It was observed that the shear reinforcement in the ribs did not increase the failure loads and that the shear reinforcement in the solid region increased significantly the resistance of the slabs. / Lajes lisas nervuradas bidirecionais são elementos estruturais de concreto armado apoiados diretamente sobre pilares, sujeitas a solicitações importantes nas duas direções, possibilitam maior velocidade na execução da obra e economia considerável de formas e concreto e, conseqüentemente, mão-de-obra. Este trabalho visa contribuir para o estudo do comportamento deste tipo de laje, quanto a resistência ao cisalhamento nas nervuras e à punção na região maciça das lajes, através de ensaios de 8 lajes lisas nervuradas bidirecionais de concreto armado. Foram realizadas análises comparativas entre os resultados obtidos experimentalmente e os fornecidos por normas técnicas nacionais e internacionais. As lajes eram quadradas de lado igual a 1.800 mm de comprimento e altura total de 140 mm. A seção transversal das lajes foi formada por nervuras de 50 mm de largura na base menor e 100 mm na base maior e os vazios entre as nervuras foram preenchidos com blocos de EPS (poliestireno expandido). As principais variáveis consideradas foram o tipo de armadura de cisalhamento nas nervuras (treliça, estribo vertical fechado e estribo aberto inclinado a 45) e a utilização de estribo aberto inclinado a 45 como armadura de punção na região maciça. Foram apresentados e analisados os resultados observados para os deslocamentos verticais, deformação nas armaduras de cisalhamento e de flexão, e a propagação das fissuras. Os valores observados para cargas últimas foram comparados com os resultados estimados. Observou-se que as armaduras de cisalhamento nas nervuras não ocasionaram ganhos significativos na resistência última e que a armadura de punção elevou significativamente a resistência das lajes.