• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Bygg- och rivningsavfall- Hanteras kakel och klinker på rätt sätt? / Construction- and demolition wasteAre tile and clinker handled correctly?

Läckgren, Robin, Osama, Yesen January 2014 (has links)
Inom byggbranschen omsätts stora mängder byggavfall. Avfallet är svårt att hantera för att det består av så stora mängder. Restavfall som kommer från en byggarbetsplats källsorteras. Avfall från byggnation och rivning innehåller många olika typer av miljöfarliga ämnen, vilket förorsakar miljöföroreningar. Farliga ämnen riskerar att läcka ut i marken och ut i naturen. Branschen har funderat på om kakel och klinkers verkligen deponeras på rätt sätt idag från byggavfall och rivning. Syftet med arbetet var att undersöka om kakel och klinkers innehåller metaller som kan vara miljöfarliga. Halterna i ytskikten uppmättes och genom att utföra laktester kunde vi analysera avgivningen från materialen i olika miljöer. Det visade sig att kakel och klinker innehåller höga halter av metaller som kan läcka ut till omgivningen vid lågt pH-värde. Slutsatsen från laktesterna är att om kakel och klinker hanteras på rätt sätt i neutral eller basisk miljö är det inte miljöfarligt, eftersom samtliga utlakningsvärden vid pH åtta till tio låg inom gränserna. Men vi ser en fara om kakel och klinker hamnar i en sur miljö som har ett lågt pH runt fem till sex. Då är kakel och klinker inte inert avfall och skall alltså inte hanteras som det. Detta gör att kakel och klinker inte bör användas som till exempel fyllnadsmassor, utan att det bör deponeras som det görs idag. Arbetet bygger till stor del på diskussioner och samtal med Structor i Örebro och MTM på Örebro Universitet. / The construction industry deals with large quantities of construction waste. The waste is difficult to manage because of large amounts. Residual waste that comes from a construction site is recycled. Waste from construction and demolition includes many different types of pollutants causing environmental pollution. Hazardous substances likely to leach into the soil and into the wild. Structor have been thinking about if tile and clinkers tiles really are deposited in the right way today from construction waste and demolition. The purpose of this work is to investigate whether tile and clinker contains metals that can be harmful to the environment. The contents in the surface layers were measured and by performing leaching tests, we could analyze the leakage from materials in different surroundings. The samples proved that tile and clinker have high level of metals in the materials that can be given off to the environment at low pH. The conclusion from the leaching tests is that if the tiles are handled properly in the neutral or alkaline environment, it is not harmful to the environment because all results of leaching tests at pH values between eight and ten were within limits. But we see a danger if tiles end up in an acidic environment that has a low pH of around five to six. Then the tiles are not inert waste and therefore should not be handled like that. Tiles should thus not be used to such as aggregate, but it should be deposited as is done today. The work is largely based on discussions and conversations with Structor in Örebro and MTM at Örebro University.
2

Ensaios geoelétricos 2D no antigo lixão de Ribeirão Preto-SP: avaliação de parâmetros de aquisição e monitoramento ambiental do problema / Geoelectrical 2D investigations in the old landfill site at Ribeirão Preto city, São Paulo, Brazil: Acquisition parameters evaluation and environmental monitoring.

Fachin, Sérgio Junior da Silva 14 September 2007 (has links)
Em razão da crescente preocupação com a proteção ao meio ambiente e preservação da qualidade das águas superficiais e subterrâneas, as áreas de disposição de resíduos, tanto domésticos como industriais, têm merecido especial atenção das instituições de pesquisa ligadas à proteção ambiental. Atualmente o uso dos métodos geoelétricos vem se destacando como metodologia indireta de investigação de áreas afetadas pela disposição inadequada de resíduos sólidos urbanos e industriais pois fornecem, desde que adequadamente escolhidas as técnicas e os parâmetros de aquisição, informações importantes com respeito à localização e geometria dos depósitos de resíduos, extensão da pluma de contaminação, posição da zona saturada e sentido do fluxo subterrâneo, características litológicas e presença de estruturas geológicas. A integração de ferramentas como simulações e métodos de interpretação qualitativa e quantitativa também auxiliam na caracterização e monitoramento ambiental de áreas de disposição de resíduos sólidos. O objetivo principal deste trabalho foi a avaliação de alguns parâmetros de aquisição 2D (arranjos eletródicos, espaçamento entre eletrodos e níveis de investigação) com os métodos da Eletrorresistividade e da Polarização Induzida, para caracterização e monitoramento ambiental. Esta avaliação foi realizada através do uso de modelagens diretas bidimensionais e ensaios de campo, tendo como área de estudos o antigo lixão do município de Ribeirão Preto-SP. O uso das modelagens diretas permitiu escolher os melhores parâmetros de aquisição de acordo com as respostas obtidas pelo modelo geológico-geofísico simulado. Os parâmetros de aquisição testados em campo refletiram os resultados obtidos através das modelagens diretas. O arranjo Polo-dipolo (a= 5 metros e n= 10) apresentou os melhores resultados (melhor resolução lateral e maior profundidade de investigação). Os resultados obtidos com as investigações de campo comparados com resultados anteriores (1997), mostraram que ainda há contaminação, marcada por baixos valores de resistividade elétrica (1 à 30 Ohm.m) e altos valores de cargabilidade (15 à 50 mV/V). / Due to the increasing concern with the environmental protection and preservation of the shallow water and groundwater aquifers quality, the areas of disposal of residues, have been special attention of the environmental protection agency. Currently the geoelectrical methods have been largely used as an investigation non-evasive methodology in affected areas by inadequate disposal of urban solid and industrial residues, because it provides information of the localization and geometrical characteristics of the waste disposal, contamination plume extent, saturated zone position, underground flow direction and geologic characteristic, if the techniques and the acquisition parameters are adequately chosen. The simulations and interpretation methods also assists during the characterization and environmental monitoring of landfill areas. The objective of this research was the evaluation of the acquisition field parameters (electrodes arrays, electrodes spacing and number of the investigations levels) and 2D investigations with the resistivity and induced polarization methods for characterization and environmental monitoring. This evaluation was carried through the use of 2D forward modeling and field investigations in old landfill site at Ribeirão Preto city, São Paulo, Brazil. The use of the forward modeling allowed to choose the best field acquisition parameters in accordance with the answers for the geologic-geophysical simulated model. The comparison between our results and previous results showed contamination marked for low electric resistivity values (1 ? 30 Ohm.m) and high chargeability values (15 ? 50 mV/V) and also that the tested parameters of acquisition in agreement with the results of the forward modeling. The Pole-dipole array (a= 5 meters and n= 10) show the best result (resolution image and investigation depth), forward modelling and field acquisition.
3

Ensaios geoelétricos 2D no antigo lixão de Ribeirão Preto-SP: avaliação de parâmetros de aquisição e monitoramento ambiental do problema / Geoelectrical 2D investigations in the old landfill site at Ribeirão Preto city, São Paulo, Brazil: Acquisition parameters evaluation and environmental monitoring.

Sérgio Junior da Silva Fachin 14 September 2007 (has links)
Em razão da crescente preocupação com a proteção ao meio ambiente e preservação da qualidade das águas superficiais e subterrâneas, as áreas de disposição de resíduos, tanto domésticos como industriais, têm merecido especial atenção das instituições de pesquisa ligadas à proteção ambiental. Atualmente o uso dos métodos geoelétricos vem se destacando como metodologia indireta de investigação de áreas afetadas pela disposição inadequada de resíduos sólidos urbanos e industriais pois fornecem, desde que adequadamente escolhidas as técnicas e os parâmetros de aquisição, informações importantes com respeito à localização e geometria dos depósitos de resíduos, extensão da pluma de contaminação, posição da zona saturada e sentido do fluxo subterrâneo, características litológicas e presença de estruturas geológicas. A integração de ferramentas como simulações e métodos de interpretação qualitativa e quantitativa também auxiliam na caracterização e monitoramento ambiental de áreas de disposição de resíduos sólidos. O objetivo principal deste trabalho foi a avaliação de alguns parâmetros de aquisição 2D (arranjos eletródicos, espaçamento entre eletrodos e níveis de investigação) com os métodos da Eletrorresistividade e da Polarização Induzida, para caracterização e monitoramento ambiental. Esta avaliação foi realizada através do uso de modelagens diretas bidimensionais e ensaios de campo, tendo como área de estudos o antigo lixão do município de Ribeirão Preto-SP. O uso das modelagens diretas permitiu escolher os melhores parâmetros de aquisição de acordo com as respostas obtidas pelo modelo geológico-geofísico simulado. Os parâmetros de aquisição testados em campo refletiram os resultados obtidos através das modelagens diretas. O arranjo Polo-dipolo (a= 5 metros e n= 10) apresentou os melhores resultados (melhor resolução lateral e maior profundidade de investigação). Os resultados obtidos com as investigações de campo comparados com resultados anteriores (1997), mostraram que ainda há contaminação, marcada por baixos valores de resistividade elétrica (1 à 30 Ohm.m) e altos valores de cargabilidade (15 à 50 mV/V). / Due to the increasing concern with the environmental protection and preservation of the shallow water and groundwater aquifers quality, the areas of disposal of residues, have been special attention of the environmental protection agency. Currently the geoelectrical methods have been largely used as an investigation non-evasive methodology in affected areas by inadequate disposal of urban solid and industrial residues, because it provides information of the localization and geometrical characteristics of the waste disposal, contamination plume extent, saturated zone position, underground flow direction and geologic characteristic, if the techniques and the acquisition parameters are adequately chosen. The simulations and interpretation methods also assists during the characterization and environmental monitoring of landfill areas. The objective of this research was the evaluation of the acquisition field parameters (electrodes arrays, electrodes spacing and number of the investigations levels) and 2D investigations with the resistivity and induced polarization methods for characterization and environmental monitoring. This evaluation was carried through the use of 2D forward modeling and field investigations in old landfill site at Ribeirão Preto city, São Paulo, Brazil. The use of the forward modeling allowed to choose the best field acquisition parameters in accordance with the answers for the geologic-geophysical simulated model. The comparison between our results and previous results showed contamination marked for low electric resistivity values (1 ? 30 Ohm.m) and high chargeability values (15 ? 50 mV/V) and also that the tested parameters of acquisition in agreement with the results of the forward modeling. The Pole-dipole array (a= 5 meters and n= 10) show the best result (resolution image and investigation depth), forward modelling and field acquisition.

Page generated in 0.0591 seconds