Spelling suggestions: "subject:"aeroacoustic"" "subject:"aeracoustic""
1 |
Laser-akustische Messtechnik in der MaterialcharakterisierungWindisch, Thomas 19 October 2016 (has links) (PDF)
Testing equipment based on the propagation of elastic waves are commonly used for measuring specific material properties. As a prerequisite for accurate measurements a reliable acoustic coupling of probe and specimen is highly important. Therefore, high-resolution testing equipment is using fluids as couplant. In certain conditions, only non-contacting methods can be considered. This is the case for example, if particular high or low temperatures are present, if topographic features impede the use of ultrasonic probes, diffusion or solubility processes exist, measurements at vacuum are addressed and if high purity requirements need to be fulfilled. Hence, subject of this work is a method which offers to handle these constraints.
With the emergence of modern laser systems the scientific basics for a non-contacting, laser-acoustic excitation of ultrasound were discovered. The tremendous development of commercially available laser systems during the last decade was taken as reason to investigate, to which extent former scientifically designed laboratory setups can now be merged into one single application oriented measuring system. All considerations are based on the thermoelastic excitation of ultrasound in combination with a likewise laser-based detection. By this, a self-contained measuring chain is built which combines the attributes non-destructive, non-contacting and application oriented within one ultrasonic measurement system for the first time.
Thermal calculations lead to more precise equations which predict a laser-induced, local temperature rise of about 100 K. The examination of sound field simulations, as a prerequisite for the design of ultrasonic systems, identified an additional complex of problems. Although existing calculation approaches presuppose laser intensity profiles what can be described in analytical terms, real-world laser sources exhibit a complex shaped spatial distribution of laser energy. Based on a preceding CEFIT simulation, the developed CPSS method enables the calculation of the time resolved, 3D wave propagation of arbitrary shaped sources. A comparison to measured data successfully validated the results of simulation.
By presenting selected scenario of measurements, the practical suitability of this non-contacting method is demonstrated. Using a transmission setup enables the characterization of open-pore ceramic coatings as well as the deduction of longitudinal and transversal speeds of sound. Equally, the imaging and estimation of the depth position of artificial defects with 0.7 mm in diameter is shown. Measurements based on a reflection setup provided evidence of a resolution limit of at least FBH = 1 mm in 4.5 mm depth. Additional examples demonstrate the ability to detect close-surface defects, the analysis of the challenging lamb waves zero-group-velocity S1 mode as well as the utilization of buried laser-acoustic sources. / Prüfsysteme, welche die Ausbreitungseigenschaften elastischer Wellen zur Ableitung spezifischer Messgrößen nutzen, sind etablierte Messverfahren. Voraussetzung für zuverlässige Ergebnisse ist stets die sichere akustische Kopplung zwischen Sensor und Material. Daher arbeiten hochauflösende Prüfsysteme mit Fluiden als Koppelmedium. Unter bestimmten Bedingungen scheiden kontaktierende Ultraschallsysteme allerdings ersatzlos aus. Dies ist beispielsweise der Fall, wenn die Probe eine besonders niedrige oder hohe Temperatur besitzt, topografische Eigenschaften ein sicheres Ankoppeln der Kontaktprüfköpfe erschweren, Diffusionsvorgänge oder Löslichkeiten zu beachten sind, in Vakuum zu arbeiten ist oder erhöhte Reinheitsanforderungen vorliegen. Gegenstand der vorliegenden Arbeit ist eine Technik welche hilft, diese Einschränkungen zu umgehen.
Mit dem Aufkommen der ersten Laserquellen entstanden die wissenschaftlichen Grundlagen zur kontaktlosen Anregung und Detektion von Ultraschall. Die rasante Entwicklung kommerziell verfügbarer Lasersysteme der vergangenen Dekade wurde zum Anlass genommen zu untersuchen, in wie weit sich die einst wissenschaftlich orientierte Laboraufbauten zu einem anwendungsnahen Messsystem zusammenführen lassen. Basis der Arbeiten ist die thermoelastische Anregung von Ultraschall in Kombination mit einer ebenfalls kontaktlosen Detektion. Damit entsteht eine geschlossene Messkette welche erstmals die Eigenschaften zerstörungsfrei, kontaktlos und anwendungsorientiert in einem Ultraschallmesssystem vereint.
Ausgangspunkt stellt die thermische Simulation der Anregung dar. Mit Hilfe präzisierter Gleichungen wird eine lokale Erwärmung von lediglich 100 K vorausgesagt. Für die zur Auslegung eines akustischen Messsystems notwendige Schallfeldsimulation wurde eine weitere Problematik identifiziert. Während bekannte Rechenansätze stets analytisch beschreibbare Strahlprofile des Lasers voraussetzen, zeigen reale Laserquellen kompliziert gestaltete räumliche Intensitätsverteilungen. Auf Basis einer vorangestellten CEFIT-Simulation ist mit der entwickelten CPSS-Methode eine zeitdiskrete Berechnung der 3D-Wellenausbreitung beliebiger Quellgeometrien möglich. Vergleiche mit realen Messdaten bestätigen die Simulationsrechnungen.
Anhand ausgewählter Messszenarien wird die Praxistauglichkeit der kontaktlosen Arbeitsweise demonstriert. Neben der Charakterisierung einer offenporigen keramischen Beschichtung erlauben Transmissionsmessungen die Berechnung der longitudinalen und transversalen Schallgeschwindigkeiten. Ebenso ist die Abbildung wie auch die Beurteilung der Tiefenlage von Referenzfehlern mit lediglich 0,7 mm Durchmesser möglich. In Reflexionsmessungen wurde eine Auflösungsgrenze von mindestens KSR = 1 mm in 4,5 mm Tiefe nachgewiesen. Weitere Beispiele zeigen die Sensitivität hinsichtlich oberflächennaher Fehler, die Auswertung der anspruchsvollen „Zero Group Velocity“ S1-Mode der Lambwelle wie auch die Nutzung eingebetteter Quellen.
|
2 |
Laser-akustische Messtechnik in der Materialcharakterisierung: Numerische Schallfeldberechnung und praxisgerechte Auslegung für die kontaktlose VolumenprüfungWindisch, Thomas 24 February 2016 (has links)
Testing equipment based on the propagation of elastic waves are commonly used for measuring specific material properties. As a prerequisite for accurate measurements a reliable acoustic coupling of probe and specimen is highly important. Therefore, high-resolution testing equipment is using fluids as couplant. In certain conditions, only non-contacting methods can be considered. This is the case for example, if particular high or low temperatures are present, if topographic features impede the use of ultrasonic probes, diffusion or solubility processes exist, measurements at vacuum are addressed and if high purity requirements need to be fulfilled. Hence, subject of this work is a method which offers to handle these constraints.
With the emergence of modern laser systems the scientific basics for a non-contacting, laser-acoustic excitation of ultrasound were discovered. The tremendous development of commercially available laser systems during the last decade was taken as reason to investigate, to which extent former scientifically designed laboratory setups can now be merged into one single application oriented measuring system. All considerations are based on the thermoelastic excitation of ultrasound in combination with a likewise laser-based detection. By this, a self-contained measuring chain is built which combines the attributes non-destructive, non-contacting and application oriented within one ultrasonic measurement system for the first time.
Thermal calculations lead to more precise equations which predict a laser-induced, local temperature rise of about 100 K. The examination of sound field simulations, as a prerequisite for the design of ultrasonic systems, identified an additional complex of problems. Although existing calculation approaches presuppose laser intensity profiles what can be described in analytical terms, real-world laser sources exhibit a complex shaped spatial distribution of laser energy. Based on a preceding CEFIT simulation, the developed CPSS method enables the calculation of the time resolved, 3D wave propagation of arbitrary shaped sources. A comparison to measured data successfully validated the results of simulation.
By presenting selected scenario of measurements, the practical suitability of this non-contacting method is demonstrated. Using a transmission setup enables the characterization of open-pore ceramic coatings as well as the deduction of longitudinal and transversal speeds of sound. Equally, the imaging and estimation of the depth position of artificial defects with 0.7 mm in diameter is shown. Measurements based on a reflection setup provided evidence of a resolution limit of at least FBH = 1 mm in 4.5 mm depth. Additional examples demonstrate the ability to detect close-surface defects, the analysis of the challenging lamb waves zero-group-velocity S1 mode as well as the utilization of buried laser-acoustic sources. / Prüfsysteme, welche die Ausbreitungseigenschaften elastischer Wellen zur Ableitung spezifischer Messgrößen nutzen, sind etablierte Messverfahren. Voraussetzung für zuverlässige Ergebnisse ist stets die sichere akustische Kopplung zwischen Sensor und Material. Daher arbeiten hochauflösende Prüfsysteme mit Fluiden als Koppelmedium. Unter bestimmten Bedingungen scheiden kontaktierende Ultraschallsysteme allerdings ersatzlos aus. Dies ist beispielsweise der Fall, wenn die Probe eine besonders niedrige oder hohe Temperatur besitzt, topografische Eigenschaften ein sicheres Ankoppeln der Kontaktprüfköpfe erschweren, Diffusionsvorgänge oder Löslichkeiten zu beachten sind, in Vakuum zu arbeiten ist oder erhöhte Reinheitsanforderungen vorliegen. Gegenstand der vorliegenden Arbeit ist eine Technik welche hilft, diese Einschränkungen zu umgehen.
Mit dem Aufkommen der ersten Laserquellen entstanden die wissenschaftlichen Grundlagen zur kontaktlosen Anregung und Detektion von Ultraschall. Die rasante Entwicklung kommerziell verfügbarer Lasersysteme der vergangenen Dekade wurde zum Anlass genommen zu untersuchen, in wie weit sich die einst wissenschaftlich orientierte Laboraufbauten zu einem anwendungsnahen Messsystem zusammenführen lassen. Basis der Arbeiten ist die thermoelastische Anregung von Ultraschall in Kombination mit einer ebenfalls kontaktlosen Detektion. Damit entsteht eine geschlossene Messkette welche erstmals die Eigenschaften zerstörungsfrei, kontaktlos und anwendungsorientiert in einem Ultraschallmesssystem vereint.
Ausgangspunkt stellt die thermische Simulation der Anregung dar. Mit Hilfe präzisierter Gleichungen wird eine lokale Erwärmung von lediglich 100 K vorausgesagt. Für die zur Auslegung eines akustischen Messsystems notwendige Schallfeldsimulation wurde eine weitere Problematik identifiziert. Während bekannte Rechenansätze stets analytisch beschreibbare Strahlprofile des Lasers voraussetzen, zeigen reale Laserquellen kompliziert gestaltete räumliche Intensitätsverteilungen. Auf Basis einer vorangestellten CEFIT-Simulation ist mit der entwickelten CPSS-Methode eine zeitdiskrete Berechnung der 3D-Wellenausbreitung beliebiger Quellgeometrien möglich. Vergleiche mit realen Messdaten bestätigen die Simulationsrechnungen.
Anhand ausgewählter Messszenarien wird die Praxistauglichkeit der kontaktlosen Arbeitsweise demonstriert. Neben der Charakterisierung einer offenporigen keramischen Beschichtung erlauben Transmissionsmessungen die Berechnung der longitudinalen und transversalen Schallgeschwindigkeiten. Ebenso ist die Abbildung wie auch die Beurteilung der Tiefenlage von Referenzfehlern mit lediglich 0,7 mm Durchmesser möglich. In Reflexionsmessungen wurde eine Auflösungsgrenze von mindestens KSR = 1 mm in 4,5 mm Tiefe nachgewiesen. Weitere Beispiele zeigen die Sensitivität hinsichtlich oberflächennaher Fehler, die Auswertung der anspruchsvollen „Zero Group Velocity“ S1-Mode der Lambwelle wie auch die Nutzung eingebetteter Quellen.
|
Page generated in 0.0661 seconds