Spelling suggestions: "subject:"ligas alternativa""
1 |
Avaliação da adaptação marginal e rugosidade de superfície de copings confeccionados de Níquel-Cromo e Cobalto-Cromo injetados em moldes de revestimento a temperatura reduzida / Evaluation of the marginal fit and surface roughness of Nickel Cromium and Cobalt Cromium copings injected in refractory molds under reduced temperatureDias, Ana Paula 30 June 2017 (has links)
A adaptação marginal e a rugosidade de superfície são parâmetros fundamentais para o sucesso clinico e longevidade das coroas metalocerâmicas. O primeiro permite o selamento das bordas do preparo, prevenindo contra problemas relacionados a exposição do preparo aos fluidos orais e a placa bacteriana e o segundo, remete ao auxilio de uma boa adaptação a fatores mecânicos e biológicos importantes a qualidade da restauração final. Visto que ambos os aspectos são diretamente relacionados a temperatura em que as ligas são submetidas, o objetivo deste trabalho foi avaliar o desajuste marginal, por meio de microscopia óptica, e rugosidade de superfície, por meio de microscopia confocal, de copings metálicos obtidos com as ligas metalicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen) injetadas no molde de revestimento a duas diferentes temperaturas de estufagem (900°C e 700°C), de forma a avaliar se a redução da temperatura de estufagem possa causar o melhoramento do resultado das fundições, minimizando os efeitos das altas temperaturas. As leituras foram realizadas em copings confeccionados a partir da fundição de casquetes de munhão calcináveis. Cada coping foi cimentado a uma matriz (munhão) por meio de um padronizador da pressão de assentamento e levado aos respectivos microscópios para leitura de desajuste marginal e rugosidade de superfície. Para a avaliação do desajuste marginal foi calculada a media das distancias da borda da restauração a borda do preparo a partir de um ponto inicial aleatório selecionado sobre a margem cervical do coping. Duas leituras eram realizadas a cada ¼ de volta, totalizando 8 leituras por coping. Para os dados obtidos, que tiveram distribuição não normal, foi utilizado o teste não paramétrico de Kruskal Wallis e foi observado que a liga VB apresentou menor desajuste marginal (56,92µm) quando comparado a liga Keragen (66,75 µm) com p<0,05 e a liga SR apresentou resultado intermediário (49,87µm), sem diferença estatística entre as demais. Para comparação das temperaturas foi utilizado o teste Mann-Whitney e a fundição a 700 °C resultou em melhor adaptação marginal que a 900 °C (50,75 µm e 66,75 µm, respectivamente) com p=0,045. Para a avaliação da rugosidade foi selecionada uma área do coping distante 100 m da borda cervical da peca e realizada a leitura. Os dados de rugosidade de superfície seguiram distribuição normal, sendo utilizado um teste paramétrico (ANOVA), seguindo pelo teste de Bonferroni. Ao se compararem as Ligas, SR apresentou menor rugosidade que Keragen (p=0,002) e que Vera Bond (p=0,001); ao se compararem as temperaturas a fundição a 700 °C resultou em menor rugosidade que a 900 °C (p=0,045). O que se concluiu com a presente metodologia apresentada foi que o comportamento das ligas as diferentes temperaturas varia de acordo com a sua composição tanto em relação a superfície quanto a adaptação marginal e que a fundição a 700 °C proporcionou obtenção dos melhores resultados em ambas as variáveis, sendo possível a otimização da superfície da peca fundida sem o comprometimento da adaptação marginal por meio da redução da temperatura de injeção da liga no molde, favorecendo o resultado final das restaurações. / A proper marginal fit and surface roughness are fundamental aspects for the clinical success of metal-ceramic crowns. The first parameter allows to preserve the margins adaptation accuracy of the restaurations, thus preventing issues related to an improper exposition of the dental tissues into the oral fluids and biofilm. The second parameter is related to mechanical and biological important aspects for the restoration quality and is also able to optimize the piece final adaptation. Both parameters are associated to temperature levels and the understanding of their behavior is convenient for the improvement of the Fixed Prostheses, therefore the aim of this study was to mensure the maginal gap by using the optical microscopy and evaluate the surface roughness by confocal microscopy of metallic copings fused with Nickel-Chromium alloys [Verabond II e experimental (SR)] and Cobalt- Chromium (Keragen) under two distinct mold temperature for the alloy injection: 700°C and 900°C. Performing those analysis represents a way to find out if the temperature reduction of the mold can be convenient to increase the quality of the casting patterns`s surface without affect the marginal fidelity, thus minimizing the overheat casting problems. The mensurements were performed in copings fused from resin cylinders for casting and each one, after fused, was cimented in a abutment cylinder analogue with standardized pression and placed under the respective microscopes for marginal fit and surface analyses. For the marginal fit mensurement were selected two equidistant points in a metal coping that representing ¼ turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Once it was found a non-normal distribution, the non-parametric Kruskal Wallis test was performed for the data and was observed that the allow VBII conferred lower values of marginal fit (56,92 µm) when compared to Keragen alloy (66,75 µm), p<0,05, and SR conferred average values between the others (49,87 µm),with no statistic difference. In the comparison between the mold temperatures the Mann-Whitney test was implemented and the temperature at 700°C reveled better results of marginal fit than the 900 °C temperature (50,75 µm e 66,75 µm, respectively) with p=0,045.For the surface analysis was selected an anatomic reference line in each coping and was set up a distance of 100 µm from this point to make the quantification. For the surface roughness data, with normal distribution, comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test. The level of significance was set at 5%. At the comparison of alloys, the SR granted lower values of roughness in its patterns than Keragen (p=0.002) and Verabond II (p=0,001). Comparing the temperatures, the values of roughness of the patterns fused under 700° were lower than those fused under 900° (p=0,045). There was no significant difference for interaction between alloy X temperature (p=0,280). The conclusion of the present study was that the behavior of the alloys regarding the marginal fit and surface roughness vary depending of its composition and the Mold temperature and Pieces injected at 700°C in the mold conferred better results in both parameters, therefore being possible to optimize the fixed photesis casting patterns surfaces without marginal fit commitment by reducing the mold temperature for the alloy injection, thus Contributing to the quality of the metal ceramic restorations.
|
2 |
Avaliação da adaptação marginal e rugosidade de superfície de copings confeccionados de Níquel-Cromo e Cobalto-Cromo injetados em moldes de revestimento a temperatura reduzida / Evaluation of the marginal fit and surface roughness of Nickel Cromium and Cobalt Cromium copings injected in refractory molds under reduced temperatureAna Paula Dias 30 June 2017 (has links)
A adaptação marginal e a rugosidade de superfície são parâmetros fundamentais para o sucesso clinico e longevidade das coroas metalocerâmicas. O primeiro permite o selamento das bordas do preparo, prevenindo contra problemas relacionados a exposição do preparo aos fluidos orais e a placa bacteriana e o segundo, remete ao auxilio de uma boa adaptação a fatores mecânicos e biológicos importantes a qualidade da restauração final. Visto que ambos os aspectos são diretamente relacionados a temperatura em que as ligas são submetidas, o objetivo deste trabalho foi avaliar o desajuste marginal, por meio de microscopia óptica, e rugosidade de superfície, por meio de microscopia confocal, de copings metálicos obtidos com as ligas metalicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen) injetadas no molde de revestimento a duas diferentes temperaturas de estufagem (900°C e 700°C), de forma a avaliar se a redução da temperatura de estufagem possa causar o melhoramento do resultado das fundições, minimizando os efeitos das altas temperaturas. As leituras foram realizadas em copings confeccionados a partir da fundição de casquetes de munhão calcináveis. Cada coping foi cimentado a uma matriz (munhão) por meio de um padronizador da pressão de assentamento e levado aos respectivos microscópios para leitura de desajuste marginal e rugosidade de superfície. Para a avaliação do desajuste marginal foi calculada a media das distancias da borda da restauração a borda do preparo a partir de um ponto inicial aleatório selecionado sobre a margem cervical do coping. Duas leituras eram realizadas a cada ¼ de volta, totalizando 8 leituras por coping. Para os dados obtidos, que tiveram distribuição não normal, foi utilizado o teste não paramétrico de Kruskal Wallis e foi observado que a liga VB apresentou menor desajuste marginal (56,92µm) quando comparado a liga Keragen (66,75 µm) com p<0,05 e a liga SR apresentou resultado intermediário (49,87µm), sem diferença estatística entre as demais. Para comparação das temperaturas foi utilizado o teste Mann-Whitney e a fundição a 700 °C resultou em melhor adaptação marginal que a 900 °C (50,75 µm e 66,75 µm, respectivamente) com p=0,045. Para a avaliação da rugosidade foi selecionada uma área do coping distante 100 m da borda cervical da peca e realizada a leitura. Os dados de rugosidade de superfície seguiram distribuição normal, sendo utilizado um teste paramétrico (ANOVA), seguindo pelo teste de Bonferroni. Ao se compararem as Ligas, SR apresentou menor rugosidade que Keragen (p=0,002) e que Vera Bond (p=0,001); ao se compararem as temperaturas a fundição a 700 °C resultou em menor rugosidade que a 900 °C (p=0,045). O que se concluiu com a presente metodologia apresentada foi que o comportamento das ligas as diferentes temperaturas varia de acordo com a sua composição tanto em relação a superfície quanto a adaptação marginal e que a fundição a 700 °C proporcionou obtenção dos melhores resultados em ambas as variáveis, sendo possível a otimização da superfície da peca fundida sem o comprometimento da adaptação marginal por meio da redução da temperatura de injeção da liga no molde, favorecendo o resultado final das restaurações. / A proper marginal fit and surface roughness are fundamental aspects for the clinical success of metal-ceramic crowns. The first parameter allows to preserve the margins adaptation accuracy of the restaurations, thus preventing issues related to an improper exposition of the dental tissues into the oral fluids and biofilm. The second parameter is related to mechanical and biological important aspects for the restoration quality and is also able to optimize the piece final adaptation. Both parameters are associated to temperature levels and the understanding of their behavior is convenient for the improvement of the Fixed Prostheses, therefore the aim of this study was to mensure the maginal gap by using the optical microscopy and evaluate the surface roughness by confocal microscopy of metallic copings fused with Nickel-Chromium alloys [Verabond II e experimental (SR)] and Cobalt- Chromium (Keragen) under two distinct mold temperature for the alloy injection: 700°C and 900°C. Performing those analysis represents a way to find out if the temperature reduction of the mold can be convenient to increase the quality of the casting patterns`s surface without affect the marginal fidelity, thus minimizing the overheat casting problems. The mensurements were performed in copings fused from resin cylinders for casting and each one, after fused, was cimented in a abutment cylinder analogue with standardized pression and placed under the respective microscopes for marginal fit and surface analyses. For the marginal fit mensurement were selected two equidistant points in a metal coping that representing ¼ turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Once it was found a non-normal distribution, the non-parametric Kruskal Wallis test was performed for the data and was observed that the allow VBII conferred lower values of marginal fit (56,92 µm) when compared to Keragen alloy (66,75 µm), p<0,05, and SR conferred average values between the others (49,87 µm),with no statistic difference. In the comparison between the mold temperatures the Mann-Whitney test was implemented and the temperature at 700°C reveled better results of marginal fit than the 900 °C temperature (50,75 µm e 66,75 µm, respectively) with p=0,045.For the surface analysis was selected an anatomic reference line in each coping and was set up a distance of 100 µm from this point to make the quantification. For the surface roughness data, with normal distribution, comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test. The level of significance was set at 5%. At the comparison of alloys, the SR granted lower values of roughness in its patterns than Keragen (p=0.002) and Verabond II (p=0,001). Comparing the temperatures, the values of roughness of the patterns fused under 700° were lower than those fused under 900° (p=0,045). There was no significant difference for interaction between alloy X temperature (p=0,280). The conclusion of the present study was that the behavior of the alloys regarding the marginal fit and surface roughness vary depending of its composition and the Mold temperature and Pieces injected at 700°C in the mold conferred better results in both parameters, therefore being possible to optimize the fixed photesis casting patterns surfaces without marginal fit commitment by reducing the mold temperature for the alloy injection, thus Contributing to the quality of the metal ceramic restorations.
|
3 |
Efeito da sinterização da cerâmica no desajuste marginal de coroas metalocerâmicas de níquel-cromo e cobalto-cromo / The effect of ceramics sintering in the marginal misfit on nickel-chromium and cobalt-chromium metal-ceramic crownsDias, Ana Paula 11 December 2013 (has links)
A adaptação marginal é fundamental para o sucesso clínico e longevidade das coroas metalocerâmicas. O objetivo deste trabalho foi avaliar, por meio de microscopia óptica, o desajuste marginal de copings metalocerâmicos obtidos com as ligas metálicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen). As leituras foram realizadas antes da sinterização (T1), após a sinterização do opaco (T2) e após a sinterização da cerâmica (T3). A partir de uma matriz metálica e uma contra-matriz de teflon, encaixada sobre o preparo da matriz, foram obtidos 30 padrões de resina acrílica Duralay/cera com espessura de 0,7 mm (n=30), que foram incluidos em anel com revestimento Microfine (Talladium). Após a fundição, os copings foram desincluídos, jateados e usinados. Cada copings, adaptado à outra matriz metálica por meio de um padronizador da pressão de assentamento, foi levado ao microscópio óptico. Foram selecionados dois pontos equidistantes de um ponto selecionado no copings, que representava ¼ de volta no dispositivo de leitura, totalizando 8 leituras por etapa em cada copings. Os dados de desajuste marginal (μm) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados mostraram que houve diferença para os fatores: tempo (p=0,00) e liga metálica (p=0,001). Com relação aos tempos, após a aplicação da cerâmica, houve maior desajuste marginal (132 μm) que após a sinterização de opaco (111,81) e antes da sinterização (90,44), com diferença entre essas duas etapas. Com relação às ligas metálicas, a liga experimental SR apresentou o menor desajuste marginal (79,75 μm) que as ligas de Ni-Cr (120,23 μm) e Co-Cr (134,28 μm) que não apresentaram diferença entre si. Não houve diferença significativa para as interações (p=0,834). Conclui-se que o desajuste marginal aumenta após as sinterizações da cerâmica e a liga experimental SR pode ser utilizada com segurança para confecção de restaurações metalocerâmicas, por apresentar os melhores resultados entre as ligas utilizadas. / The good marginal fit is a critical point for the clinical success of metal-ceramic crowns after definitive cementation. The knowledge of alloys properties, their interference factors and materials development allows the creation of new crowns within clinically acceptable marginal fit, factor that enables a good periodontal restorations performance and also prevents caries recurrences in cementation line. The present study evaluated, by optical microscopy, marginal fit in metal-ceramic crowns fused with three different alloys; Nickel-Chromium (Verabond II), Cobalt- Chromium (Keragen) and a experimetal Nickel-Chromium (SR) alloy in three distinct stages; after the cast (T1), after opaque layer application (T2) and after ceramic coating (T3). Were selected two equidistant points in a metal coping that representing ¼ turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test where applicable. The level of significance was set at 5%. The results showed there were statistical differences for such factors: time (p = 0.00) and alloy (p = 0.001). In relation to time, after ceramics application, there was higher marginal misfit (132 μm) than after opaque sintering (111.81 μm) and before sintering (90.44 μm) with differences between these two steps. In relation to alloys, the experimental SR alloy showed the lower marginal misfit (79.75 μm) than Ni-Cr alloys (120.23 μm) and Co- Cr (134.28 μm) and there was no statistical difference for these experimental groups There was no significant difference for interaction (p = 0.834). In conclusion the marginal misfit increases after ceramics sintering. Experimental SR alloy showed the best results among the alloys and can be safely used to metal ceramic restorations.
|
4 |
Avaliação da adaptação marginal de copings metálicos fundidos em ligas de níquel-cromo, níquel-cromo-berílio e em titânio comercialmente puro em função da aplicação de espaçadores / Evaluation of the use of die spacer over the marginal fit of casting copings of Ni-Cr, Ni-Cr-Be and commercially pure TitaniumNatércia Carreira Soriani 01 February 2008 (has links)
O objetivo do trabalho foi avaliar o efeito do uso de espaçadores na adaptação marginal de copings confeccionados em ligas de Ni-Cr (Verabond II) (VB II) e Ni-Cr-Be (Verabond) (VB) e Titânio cp (Tritan) (Ti-cp) fundidos pela técnica de cera perdida. A partir de uma matriz metálica, foram obtidos 135 troquéis de gesso resinado tipo IV para confecção dos padrões de cera nas seguintes condições: sem a presença de espaçador (G0), com uma camada de espaçador (G1) e com duas camadas de espaçador (G2), com quinze repetições para cada grupo. Foi realizado o enceramento de cada troquel e os padrões de cera foram incluídos em revestimento adequado para cada material. Em cada anel de fundição foram incluídos 3 padrões de cera, sendo cada um correspondente a cada condição. Cada coping, adaptado à matriz metálica por meio de um dispositivo padronizador da pressão de assentamento, foi levado ao Microscópio Óptico para aferição das medidas da desadaptação marginal. Os dados obtidos (µm) foram submetidos à análise estatística (ANOVA) e teste de Tukey (p<0.05). Para a condição material, a liga VB (118,73) não apresentou diferença estatisticamente significante em relação à liga VB II (93,40), sendo que estas apresentaram diferença estatisticamente significante em relação ao Ti-cp (168,35). Em relação ao fator espaçador, houve diferença estatisticamente significante entre as três condições (G0=177,31; G1=121,51 e G2=81,66). Com base nos dados obtidos pelo presente estudo, pode-se afirmar que a presença de duas camadas de espaçador propicia menor desadaptação marginal. / The purpose of the study was to evaluate the effect of using die spacers on the marginal fit of Ni Cr (Verabond II) (VB II) and Ni-Cr-Be (Verabond) (VB) alloys and commercially pure Titanium (Tritan) (Ti-cp) casting copings by the lost wax technique. Using a metal master die, 135 Resin Added Extra Hard Type IV Stone were obtained for the fabrication of wax patterns in the following conditions: without die spacer (G0), with one die spacer layer (G1); and with two die spacer layers (G2), with fifteen repetitions for each group. Each stone die was waxed and the wax patterns were invested as recommended by the manufacturer. Three wax patterns were embedded in each casting ring, each corresponding to a condition. Each coping, seated to the metal matrix by a Seating Pressure Standardizing Device (SPSD), was taken to the Optic Microscope for the measurement of marginal discrepancy. The obtained data (µm) were submitted to statistical analysis (ANOVA) and Tukey test (p<0.05). There was not statistically significant difference among the materials VB II (93,40) and VB (118,73), and there was statistically significant different to Ti-cp (168,35) . In terms of the die spacer, there was a statistically significant difference among the three conditions (G0=177,31; G1=121,51 e G2=81,66). It was concluded that with two die spacer layers there is less marginal discrepancy.
|
5 |
Avaliação da adaptação marginal de copings metálicos fundidos em ligas de níquel-cromo, níquel-cromo-berílio e em titânio comercialmente puro em função da aplicação de espaçadores / Evaluation of the use of die spacer over the marginal fit of casting copings of Ni-Cr, Ni-Cr-Be and commercially pure TitaniumSoriani, Natércia Carreira 01 February 2008 (has links)
O objetivo do trabalho foi avaliar o efeito do uso de espaçadores na adaptação marginal de copings confeccionados em ligas de Ni-Cr (Verabond II) (VB II) e Ni-Cr-Be (Verabond) (VB) e Titânio cp (Tritan) (Ti-cp) fundidos pela técnica de cera perdida. A partir de uma matriz metálica, foram obtidos 135 troquéis de gesso resinado tipo IV para confecção dos padrões de cera nas seguintes condições: sem a presença de espaçador (G0), com uma camada de espaçador (G1) e com duas camadas de espaçador (G2), com quinze repetições para cada grupo. Foi realizado o enceramento de cada troquel e os padrões de cera foram incluídos em revestimento adequado para cada material. Em cada anel de fundição foram incluídos 3 padrões de cera, sendo cada um correspondente a cada condição. Cada coping, adaptado à matriz metálica por meio de um dispositivo padronizador da pressão de assentamento, foi levado ao Microscópio Óptico para aferição das medidas da desadaptação marginal. Os dados obtidos (µm) foram submetidos à análise estatística (ANOVA) e teste de Tukey (p<0.05). Para a condição material, a liga VB (118,73) não apresentou diferença estatisticamente significante em relação à liga VB II (93,40), sendo que estas apresentaram diferença estatisticamente significante em relação ao Ti-cp (168,35). Em relação ao fator espaçador, houve diferença estatisticamente significante entre as três condições (G0=177,31; G1=121,51 e G2=81,66). Com base nos dados obtidos pelo presente estudo, pode-se afirmar que a presença de duas camadas de espaçador propicia menor desadaptação marginal. / The purpose of the study was to evaluate the effect of using die spacers on the marginal fit of Ni Cr (Verabond II) (VB II) and Ni-Cr-Be (Verabond) (VB) alloys and commercially pure Titanium (Tritan) (Ti-cp) casting copings by the lost wax technique. Using a metal master die, 135 Resin Added Extra Hard Type IV Stone were obtained for the fabrication of wax patterns in the following conditions: without die spacer (G0), with one die spacer layer (G1); and with two die spacer layers (G2), with fifteen repetitions for each group. Each stone die was waxed and the wax patterns were invested as recommended by the manufacturer. Three wax patterns were embedded in each casting ring, each corresponding to a condition. Each coping, seated to the metal matrix by a Seating Pressure Standardizing Device (SPSD), was taken to the Optic Microscope for the measurement of marginal discrepancy. The obtained data (µm) were submitted to statistical analysis (ANOVA) and Tukey test (p<0.05). There was not statistically significant difference among the materials VB II (93,40) and VB (118,73), and there was statistically significant different to Ti-cp (168,35) . In terms of the die spacer, there was a statistically significant difference among the three conditions (G0=177,31; G1=121,51 e G2=81,66). It was concluded that with two die spacer layers there is less marginal discrepancy.
|
6 |
Efeito da sinterização da cerâmica no desajuste marginal de coroas metalocerâmicas de níquel-cromo e cobalto-cromo / The effect of ceramics sintering in the marginal misfit on nickel-chromium and cobalt-chromium metal-ceramic crownsAna Paula Dias 11 December 2013 (has links)
A adaptação marginal é fundamental para o sucesso clínico e longevidade das coroas metalocerâmicas. O objetivo deste trabalho foi avaliar, por meio de microscopia óptica, o desajuste marginal de copings metalocerâmicos obtidos com as ligas metálicas de Ni-Cr [Verabond II e experimental (SR)] e Co-Cr (Keragen). As leituras foram realizadas antes da sinterização (T1), após a sinterização do opaco (T2) e após a sinterização da cerâmica (T3). A partir de uma matriz metálica e uma contra-matriz de teflon, encaixada sobre o preparo da matriz, foram obtidos 30 padrões de resina acrílica Duralay/cera com espessura de 0,7 mm (n=30), que foram incluidos em anel com revestimento Microfine (Talladium). Após a fundição, os copings foram desincluídos, jateados e usinados. Cada copings, adaptado à outra matriz metálica por meio de um padronizador da pressão de assentamento, foi levado ao microscópio óptico. Foram selecionados dois pontos equidistantes de um ponto selecionado no copings, que representava ¼ de volta no dispositivo de leitura, totalizando 8 leituras por etapa em cada copings. Os dados de desajuste marginal (μm) foram analisados estatisticamente pelos testes ANOVA e Bonferroni (α=0,05). Os resultados mostraram que houve diferença para os fatores: tempo (p=0,00) e liga metálica (p=0,001). Com relação aos tempos, após a aplicação da cerâmica, houve maior desajuste marginal (132 μm) que após a sinterização de opaco (111,81) e antes da sinterização (90,44), com diferença entre essas duas etapas. Com relação às ligas metálicas, a liga experimental SR apresentou o menor desajuste marginal (79,75 μm) que as ligas de Ni-Cr (120,23 μm) e Co-Cr (134,28 μm) que não apresentaram diferença entre si. Não houve diferença significativa para as interações (p=0,834). Conclui-se que o desajuste marginal aumenta após as sinterizações da cerâmica e a liga experimental SR pode ser utilizada com segurança para confecção de restaurações metalocerâmicas, por apresentar os melhores resultados entre as ligas utilizadas. / The good marginal fit is a critical point for the clinical success of metal-ceramic crowns after definitive cementation. The knowledge of alloys properties, their interference factors and materials development allows the creation of new crowns within clinically acceptable marginal fit, factor that enables a good periodontal restorations performance and also prevents caries recurrences in cementation line. The present study evaluated, by optical microscopy, marginal fit in metal-ceramic crowns fused with three different alloys; Nickel-Chromium (Verabond II), Cobalt- Chromium (Keragen) and a experimetal Nickel-Chromium (SR) alloy in three distinct stages; after the cast (T1), after opaque layer application (T2) and after ceramic coating (T3). Were selected two equidistant points in a metal coping that representing ¼ turn on the measurement device, in a total of 8 measurements for coping in each step that results in a misfit average. Comparisons were performed using a parametric test for independent data (ANOVA), followed by Bonferroni test where applicable. The level of significance was set at 5%. The results showed there were statistical differences for such factors: time (p = 0.00) and alloy (p = 0.001). In relation to time, after ceramics application, there was higher marginal misfit (132 μm) than after opaque sintering (111.81 μm) and before sintering (90.44 μm) with differences between these two steps. In relation to alloys, the experimental SR alloy showed the lower marginal misfit (79.75 μm) than Ni-Cr alloys (120.23 μm) and Co- Cr (134.28 μm) and there was no statistical difference for these experimental groups There was no significant difference for interaction (p = 0.834). In conclusion the marginal misfit increases after ceramics sintering. Experimental SR alloy showed the best results among the alloys and can be safely used to metal ceramic restorations.
|
7 |
Comparative study of five Ni-Cr alloys concerning castability and reproducibility / Estudo comparativo entre cinto ligas de níquel-cromo no tocante a fluidez e consequente reprodutibilidadeMauro D Oliveira 22 December 2004 (has links)
The aim of this study was to verify the behavior of five brands of NiCr alloys, indicated to porcelain fused to metal restorations, comparing the castability with the ability of reproducing the thin edges of restoration margins. The samples were divided in five groups, each one for one brand, with ten repetitions for castability test and ten for edge reproduction, in a total of 100 specimens. A carbon free phosphate bonded investment was used for all casting procedures. Optical microscopy was used to investigate the microstructure of the specimens obtained with two of the alloys, those which have shown better results. Statistical analysis stated that the commercial brand Tilite showed both better castability and edge reproduction. / O objetivo desta pesquisa foi verificar o desempenho de cinco ligas de níquel-cromo para restaurações de metalocerâmicas, comparando a fluidez com a capacidade de cópia da borda fina das restaurações. Os corpos-de-prova foram divididos em 5 grupos um para cada liga, sendo realizado dez corpos-de-prova para o teste de fluidez e dez corpos-de-prova para o teste da cópia da borda, totalizando 100 corpos-de-prova. Um revestimento de fosfato sem carbono foi usado para todas as inclusões e fundições. Em seguida foram submetidos a microscopia óptica, para se observar a microestrutura das duas ligas que obtiveram os melhores desempenhos. Os resultados, após análise estatística, demonstraram que a liga Tilite apresentou a melhor fluidez e melhor cópia da borda.
|
8 |
Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromiumAlves, Luciana Mara Negrão 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental “SR” . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150μm) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100μm) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
|
9 |
Efeito do ambiente de sinterização na resistência de união de cerâmicas a ligas de níquel-cromo, cobalto-cromo e titânio comercialmente puro / Effect of firing atmosphere on metal ceramic bond strength of nickelchromium, cobalt-chromium and commercially pure titaniumRocha, Milena Teixeira da 23 November 2012 (has links)
O objetivo deste trabalho foi avaliar o efeito do ambiente de sinterização vácuo e argônio na resistência de união (RUMC) de cerâmicas às ligas de Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) e titânio comercialmente puro (Tritan). A partir de uma matriz de teflon, foram obtidos 60 padrões de resina/cera em forma de cilindro, com 8 mm de comprimento e 5 mm de diâmetro. Os padrões foram incluídos e os anéis foram levados ao forno e submetidos a ciclos térmicos para a expansão do revestimento. Em seguida, os anéis para fundição em Ni-Cr e Co-Cr foram levados à máquina de fundição por indução eletrônica. Os anéis referentes ao titânio foram levados à máquina de fundição por arco voltaico. Após resfriamento dos anéis, as fundições foram desincluídas e jateadas com óxido de alumínio (100 μm). Depois de recortados dos canais de alimentação, os cilindros metálicos foram preparados para aplicação da cerâmica. Em seguida, foi realizada a aplicação e sinterização da cerâmica à vácuo ou em argônio. Para as ligas alternativas, foi utilizada a cerâmica IPS Classic V e para o titânio, a Triceram. Na sequência, os cilindros compostos pelo metal e disco cerâmico (5 mm de diâmetro e 2 mm de espessura) (n=10) foram submetidos aos ensaios de RUMC por cisalhamento na máquina de ensaios universais com célula de carga de 500 Kg e velocidade do travessão móvel de 0,5 mm/min. Após os ensaios, foram realizadas análises das fraturas por meio de microscopia óptica (MO) (15X) e microscopia eletrônica de varredura (MEV). Os dados de RUMC (MPa) obtidos foram analisados estatisticamente pelos testes ANOVA e Tukey (α=0,05). Os resultados demonstraram que a sinterização à vácuo propiciou obtenção de maiores valores (MPa) de RUMC (76,58) que a sinterização em argônio (51,31). Quanto às ligas avaliadas, as de Ni-Cr e Co-Cr apresentaram maiores valores de RUMC (71,32 e 71,28, respectivamente) que o titânio cp (49,23); sendo que entre elas não houve diferença estatística. Não houve interação entre os fatores avaliados. De acordo com a MO, houve predomínio de fraturas mistas. Segundo a MEV, os espécimes de Ni-Cr e titânio sinterizados a vácuo apresentaram maior rugosidade de superfície do que os sinterizados em argônio. Para a liga de Co-Cr não houve diferença na topografia de superfície. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos analisados. / The aim of this study was to evaluate the effect of firing atmospheres: vacuum and argon on the bond strength of ceramic to Ni-Cr (Fit Cast SB), Co-Cr (Star Loy C) and commercially pure titanium (Tritan) alloys. 60 wax/acrylic resin cylinder patterns (8 mm high and 5 mm in diameter) were prepared on a plastic custom mold for metalceramic bond strength (MCBS) test. The patterns were invested in phosphated investment and manipulated on vacuum. The rings were placed in a furnace to burn out patterns and thermally expand the molds. Then, the rings of Ni-Cr and Co-Cr were placed in an electronic machine to cast. The rings related to titanium were positioned in the casting machine with a voltaic arc. After the rings have cooled, the castings were divested manually and abraded with aluminum oxide particles (100 μm). Then, the cylinders were prepared for applying of the ceramic veneering disks. The ceramic was applied and fired in vacuum and argon atmospheres. IPS-Classic ceramic was used for alternative alloys and for titanium, Triceram ceramic. Then, the cylinders composed of metal and ceramic disk (5 mm diameter and 2 mm height) (n=10) were submitted to metal-ceramic bond strength (MCBS) shear tests on an universal testing machine with load cell of 500 Kg at a crosshead speed of 0.5 mm/min. After the tests, there were made fracture analysis by optic microscopy (OM) and scanning electron microscopy (SEM). The MCBS data (MPa) were statistically analyzed by the ANOVA and Tukey test (α=0.05). The results indicated that the vacuum firing (76.58) promoted higher MCBS values than argon firing (51.31). Among the metals, Ni-Cr and Co-Cr alloys presented higher MCBS (71.32 e 71.28, respectively) than titanium (49.23); between two base alloys there was no statistical difference. There was no interaction between the evaluated factors. According to MO analysis, there was predominance of mixed fractures. According SEM, the Ni-Cr and titanium specimens submitted to vacuum presented higher surface roughness than the specimens submitted to argon. For Co-Cr, there was no difference of surface topography. The argon firing influenced negatively the MCBS of metal-ceramic evaluated pairs.
|
10 |
Efeito da atmosfera de sinterização na resistência de união da porcelana com ligas de níquel-cromo e cobalto-cromo / Effect of firing atmosphere on metal ceramic bond strength of nickel-chromium and cobalt-chromiumLuciana Mara Negrão Alves 11 February 2015 (has links)
O objetivo deste trabalho foi avaliar a influência de dois diferentes ambientes de sinterização (vácuo e argônio) sobre a resistência da união metaloceramica (RUMC) envolvendo diferentes ligas de metais básicos (Co-Cr e Ni-Cr) e uma porcelana odontológica, através do teste de flexão de três pontos, conforme preconizado pela ISO 9693:2012. As ligas estudadas foram Co-Cr: Remanium e Keragen e Ni-Cr: Verabond II e uma liga experimental “SR” . Foram obtidos 80 corpos de prova em forma tiras metálicas medindo 25 X 0,5 X 5 mm. Para esse ensaio, portanto, o número de corpos de prova foi o produto de 4 ligas x 2 condições de atmosfera de sinterização x 10 repetições. A parte metálica de todos os corpos de prova após a fundição foram usinados e jateados com óxido de alumínio (150μm) e a seguir tratados como preconizado pelo fabricante. O corpo cerâmico, com o auxílio de uma matriz, foi confeccionado na área central da tira, 8,0 X 3,0mm, apresentando 1,1mm de espessura, sendo 10 corpos de prova em cada ambiente de sinterização para cada tipo de liga. Os corpos de prova obtidos foram submetidos aos testes de flexão de três pontos na Máquina de Ensaios Mecânicos (EMIC) com velocidade de 1.0mm/min. para determinação da RUMC. Os valores da carga de ruptura obtidos em quilograma-força (Kgf) foram convertidos para Newton (N) e a partir disso foi calculado o valor da RUMC para cada corpo de prova, considerando o coeficiente de elasticidade de cada liga e a espessura exata de cada corpo de prova. Os dados obtidos (MPa) foram submetidos à análise estatística (ANOVA) e Bonferroni. A Análise de Variância indicou diferença estatisticamente significante para os fatores de variação ambiente (P=0,00), liga (P=0,009) e entre as interações ambiente de sinterização e liga (P=0,000). Na sinterização a vácuo as ligas Keragen, SR e Verabond II apresentaram maiores valores de RUMC do que o argônio. Para a liga Remanium, não houve diferença entre a sinterização em argônio e a sinterização a vácuo. Dentre os grupos sinterizados no argônio não houve diferença estatisticamente significante entre as ligas. Entretanto, no vácuo a liga Remanium apresentou menor valor de RUMC do que as demais ligas, que não apresentaram diferença entre si. Os corpos de prova, após os ensaios de flexão, foram submetidos a análise em microscopia optica, MEV e EDS para avaliar e registrar tipo de falha que sofreram. De acordo com a MO, houve predomínio de fraturas mistas. Os corpos de prova de Co-Cr (Remanium e Keragen), independende do ambiente de sinterização, apresentaram uma fina camada de óxido no corpo cerâmico, o que foi comprovado pelo EDS, com maior presença de íons Cr nessas regiões, já os grupos SR e Verabond II, apresentaram maior quantidade de opaco aderido em suas tiras metálicas. A MEV comprovou os achados da MO, onde foi possível encontrar grandes ilhas de material cerâmico nas ligas de Ni-Cr. A sinterização em argônio influenciou negativamente a RUMC dos pares metalocerâmicos confeccionados em Ni-Cr e na liga Keragem / The aim of this study was to evaluate the influence of two different firing atmosphere (vacuum and argon) on the metalceramic bond strength (MCBS) involving different base metal alloys (Co-Cr and Ni-Cr) and a dental porcelain through three-point bending test, as recommended by ISO 9693: 2012. Co-Cr alloys studied were: Remanium and Keragen and Ni-Cr: Verabond II and an experimental alloy \"SR\". 80 specimens were obtained in metallic form strips measuring 25X0.5 X 5.0 mm. For this test, therefore, the number of specimens was the product of 4 x 2 alloy sintering atmosphere conditions x 10 replicates. The metal portion of all specimens were machined after casting and sandblasted with aluminum oxide (100μm) and then treated as recommended by the manufacturer. By using a matrix, the ceramic body was made in the central area of the strip, 8.0 x 3.0 mm, it was made 1.1 mm thickness, 10 specimens in each sintering environment for each type of alloy. The specimens obtained were tested for three-point bending in a universal testing machine with a speed of 1.0mm / min. to determine MCBS. The values of the tensile strength obtained in kilogramforce (kgf) were converted into Newton (N) and from this the value of MCBS for each specimen was calculated, considering the coefficient of elasticity of each league and the exact thickness of each specimen. The data (MPa) were subjected to statistical analysis (ANOVA) and Bonferroni. The analysis of variance indicated statistically significant difference for the environment factors of firing atmosphere (P = 0.00) and alloy (P = 0.009). There was a statistically significant difference in the interaction factors for firing atmosphere x alloy (P = 0.000). In the vacuum Keragen, SR and Verabond II alloys showed higher MCBS than argon. To Remanium, there was no difference between the sintering in argon and vacuum. Among the groups sintered in argon there was no statistically significant difference between the alloys. However, the vacuum Remanium showed the lowest RUMC than other alloys, which showed no difference between them. The specimens after the bending tests, were subjected to analysis in optical microscopy, SEM and EDS to assess and record type of failure they suffered. According to the MO was predominantly mixed fractures. Specimens of Co-Cr (Remanium and Keragen) independende the atmosphere firing, showed a thin oxide layer on the ceramic body, which was confirmed by EDS, with greater presence of Cr in these regions, since the SR groups and Verabond II, presented more opaque stuck in their metal strips. SEM confirmed the findings of MO, where it was possible to find large islands of ceramic material in Ni-Cr alloys. The sintering in argon negatively influenced MCBS metalceramic of pairs made of Ni-Cr alloy and Keragem
|
Page generated in 0.1117 seconds