491

The development of a guideline to assist with compiling asset management plans for transmission lines.

Mansingh, Sharan. January 2010 (has links)
The overhead transmission line is a fundamental component in the power supply system as it links electricity supply to the various points on the electrical network. Failure of the transmission overhead line will result in interruption of supply and depending on the network configuration may result in long term outages. It is therefore essential that the overhead transmission line asset is inspected and maintained regularly to prevent premature failure. Newer approaches to maintenance management are required to improve the overhead transmission lines performance and reduce the cost and risk associated with the asset. Asset management is seen as the process that can be adopted to enhance overall management of the overhead transmission line. The review of maintenance practices of various Utility’s and that of a pilot site made up of selected lines within Eskom’s North East Transmission Grid revealed numerous shortcomings in the current practices largely due to the application of traditional (non-holistic) methods. This situation supports the development of asset management plans which will cater for improvement in performance, reduction in the risk and cost and achieving service level targets. This research has used asset management principles to design a guideline in the form of a flowchart for effective maintenance management for overhead transmission lines. The key benefits/advantages of the maintenance management guideline are as follows: It is closed loop and process driven. Decision making is more scientific because it requires the use of historical performance data, detailed asset condition information and encourages quantitative analysis. Promotes defect and condition assessment tracking via the condition database. Rather than focusing mainly on defect management, the asset manager will be directed towards the performance specifications and the condition database to establish individual action plans which can be prioritized against short, medium and long term improvement plans per specific asset. / Thesis (M.Sc.)-University of KwaZulu-Natal, Durban, 2010.
492

Cost effective DSL solutions for the developing countries.

January 2004 (has links)
Developing countries in Africa present a graphic picture of the digital divide. High costs associated with serving rural customers are the major cause of uneven distribution of services. Rural areas are characterised by a high rate of unemployment and a poor level of education. This results in a scenario where most of the residents are unable to utilize IT resources. Some people in these areas are not informed about the availability and importance of these technologies in the market. Those who are academically fit for accessing these technologies often cannot afford them. Some of the areas still have no existing telecommunications infrastructure. High deployment costs associated with broadband services makes it even more challenging to deploy such services in this environment. In Africa approximately 80% of the population is living in rural areas, which alone creates a demand for the coverage of rural regions. Leaving such a large number of residents not connected, means poor medical care, students cannot participate in distance learning programs which means poor quality of education, poor performance in businesses, poor farming and crippling delivery of government services. DSL technologies were originally designed to suit suburban to urban conditions. In this research it is shown that broadband services can be delivered to rural people by applying DSL technologies, using the existing telecommunications infrastructure. This will mean significant savings, as it does not need core network investments. DSL increases network capacity to a network, which is no longer limited to voice. With this technology a number different high bandwidth applications are delivered to the homes, schools, hospitals, telecentres and small businesses. The cost effectiveness of these technologies for several reach and rural traffic environment is investigated. This is done by investigating several promising DSL solutions in terms of diverse geography, demographics and other cost dictating parameters. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Westville, 2004.
493

A study of the electrical environment below HVDC transmission lines.

Govender, Dhevandhran. January 2008 (has links)
The main aim of this project was to determine the extent to which the study of electric fields and ions in a laboratory can be used to study the electrical environment below High Voltage Direct Current (HVDC) transmission lines. The focus of the study was to set up small scale laboratory experiments and to compare these results to actual line measurements and to software simulations. The laboratory tests were undertaken at the HVDC Centre at the University of KwaZulu-Natal (Westville Campus). The software simulations that were conducted as part of this study were done using EPRI TL 3.0 and Microsoft Excel. Initially tests conducted were the measurement of the induced voltage and corona leakage current on a floating object. The next set of laboratory tests conducted was the measurement of ion current density and the electric field at ground level. The ion current density was measured with a Wilson Plate (lm2) and the electric field at ground level was measured using a JCI static monitor field meter (JCI 140) and a Monroe (257D) Portable Electrostatic Fieldmeter, with an elevated earth plane. Measurements of ion current density and electric field at ground level were also taken under an operating HVDC transmission line (Cahora Bassa to Apollo), in order to compare the laboratory measurements and simulations with real line measurements. The results have shown that the electrical parameters (i.e. ion current, induced voltages, corona currents, electric field, ion density, space charge) are higher under the negative pole as compared to the positive pole. The results of the laboratory measurements show that the ion currents under the negative polarity are almost double the ion currents that were measured under positive polarity, while the electric field under negative polarity was 20 percent higher than under positive polarity. Measurements of the electric field show that the total electric field below the line is greatly enhanced when corona generated space charge is present. The results of the EPRI TL Workstation simulations show good correlation with the EXCEL® simulations. However, there was poor correlation between EPRI simulations and test line measurements in the laboratory. The EPRI simulations show good correlation to the measured electric field values below the Cahora Bassa line. The comparison between the actual measurements on the test line and the Cahora Bassa line showed poor correlation and this was attributed to factors such as scaling, laboratory size constraints, ion concentration in laboratory, line loading and wind speeds. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2008.
494

Dynamic characteristics of bare conductors.

Eshiemogie, Ojo Evans. January 2011 (has links)
The dynamic characteristic of transmission line conductors is very important in designing and constructing a new line or upgrading an existing one. This concept is an impediment to line design and construction because it normally determines the tension at which the line is strung and this in respect affects the tower height and the span length. Investigations into the phenomenon of mechanical oscillation of power line conductors have been extensively looked into by many researchers using concepts from mechanics and aerodynamics to try and predict the conductor dynamic behaviour. Findings have shown that precise prediction of conductor windinduced vibration is very difficult i.e. non-linearity. Over the years, various analytical models have been developed by researchers to try and predict the mechanical vibration of transmission line conductors. The first part of this dissertation considers the analysis of the model describing the transverse vibration of a conductor as a long, slender, simply supported beam, isotropic in nature and subjected to a concentrated force. The solution of this beam equation was used to obtain the conductor natural frequencies and mode shapes. Conductor self-damping was obtained by the introduction of both external and internal damping models into the equation of motion for the beam. Next, also using the same beam concept was the application of the finite element method (FEM) for the dynamic analysis of transmission line conductors. A finite element formulation was done to present a weak form of the problem; Galerkin‟s method was then applied to derive the governing equations for the finite element. Assembly of these finite element equations, the equation of motion for the transverse vibration of the conductor is obtained. A one dimensional finite element simulation was done using ABAQUS software to simulate its transverse displacement. The eigenvalues and natural frequencies for the conductors were calculated at three different tensions for two different conductors. The damping behaviour of the conductors was evaluated using the proportional damping (Rayleigh damping) model. The results obtained were then compared with the results from the analytical model and the comparison showed a very good agreement. An electrical equivalent for the conductor was developed based on the concept of mechanicalelectrical analogy, using the discrete simply supported beam model. The developed electrical equivalent circuit was then used to formulate the transfer function for the conductor. Matlab software was used to simulate the free response of the developed transfer function. Finally, the experimental study was conducted to validate both the analytical model and the FEM. Tests were done on a single span conductor using two testing methods i.e. free and force vibration. The test results are valid only for Aeolian vibration. From the test results the conductor‟s natural frequencies and damping were determined. The experimental results, as compared with the analytical results were used to validate the finite element simulation results obtained from the ABAQUS simulation. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2011.
495

Design optimisation of bare conductors for overhead line applications.

Munilall, Anandran. January 2009 (has links)
The South African economy is an emerging market and as such there is a continued and growing need for the efficient supply of cost effective electricity. The capital investment involved in the design, construction, installation and commissioning of overhead transmission line networks are high and so too are the subsequent maintenance and operation costs, incurred over their life cycle periods. The need to improve the electrical operating efficiency of existing and future electrical transmission networks, through the reduction of electrical losses, focused and motivated the research in this particular area. The results and findings produced by this research study show that the magnetic induction produced by the steel core in ACSR (Aluminium conductor, steel reinforced) conductors cause in increase in the ac power losses, associated ac-dc resistance ratio and the effective ac resistance of the conductor, whilst the conductor is energised during normal operation. More specifically, the key parameters that cause this increase in the effective ac resistance of the conductor, as a result of the magnetic induction produced by the steel core, are those of hysterisis and eddy current power losses in the steel core and an added power loss caused by the non-uniform redistribution of current in the layers of aluminum wires, due to the ‘transformer effect’. Therefore the addition of the conductor dc resistance value to the component resistances produced by the current redistribution and magnetic hysterisis & eddy current power losses, form the total effective ac conductor resistance. This is contrary to standard practice where assumption is made that the conductor ac and dc resistance values are equal. The factors which influence the magnetic induction, include amongst others; the ferromagnetic properties of the steel core, the physical construction of the conductor, the conductor operating/core temperature and the load current. In order to calculate the effective ac-resistance of multi-layer ACSR conductors a computer simulation program was developed, which was largely based on determining the impact of varying these key factors, by evaluating its effect on the ac resistance of the conductor. It was found through manipulation of these factors that the total effective ac resistance of the conductor could be reduced and significantly so with higher load currents. The conductor sample used in this research study is commonly known as TERN ACSR conductor in the South African market and it was shown that with practical changes in lay ratios or lay lengths, one is able to reduce the total effective ac resistance of the conductor and associated power losses. Several software simulation exercises were performed using the developed software simulation program, to ultimately produce a set of optimised lay-lengths (lay-ratios) for the TERN ACSR conductor, with the intention that these simulated parameters would be employed in the production of actual conductor samples. The intention going forward after the planned production trial runs would be to test these conductor samples to verify compliance, in meeting both electrical and mechanical performance requirements. It should be noted that the planned production trials and relevant conductor-testing processes did not form part of the scope of this research report but are processes that have been planned for in the near future. Although testing to IEC 61089 are post processes that are planned for outside of this research scope, the specification requirements of IEC61089 were incorporated into the various computer simulation exercises. / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2009.
496

A study and implementation analysis of an anti-sagging device for power transmission lines using shape memory alloys

31 August 2010 (has links)
Shape memory alloys (SMA’s) are a family of metals that exhibit properties of pseudo-elasticity / Thesis (M.Sc.Eng.)-University of KwaZulu-Natal, Durban, 2009.
497

Cell cycle affects accumulation of β-D-5-o-Carboranyl-2'-Deoxyuridine(D-CDU) in human glioma cell line

Moore, Casey Benjamin 12 1900 (has links)
No description available.
498

An analysis of the thermal stability of the soil environment of underground electrical cables

Hartley, James Gary 08 1900 (has links)
No description available.
499

Determination of effective thermal conductivity of media surrounding underground transmission cables

Wood, Sandra Jean 12 1900 (has links)
No description available.
500

Transient thermal models for substation transmission components

Coneybeer, Robert T. 08 1900 (has links)
No description available.