• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 16
  • 1
  • Tagged with
  • 17
  • 17
  • 14
  • 13
  • 7
  • 7
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Cálculo da força contra eletromotriz em máquinas síncronas com ímãs na superfície do rotor / Assessment of surface mounted magnet synchronous machine\'s on-load back-EMF

Geyverson Teixeira de Paula 28 April 2016 (has links)
O presente trabalho trata do cálculo da força contra eletromotriz em carga de uma máquina síncrona com ímãs na superfície do rotor (cuja forma de onda de força contra eletromotriz é não senoidal) sendo esta alimentada por correntes de fase cujas forma de onda são quadradas. Para conduzir esta investigação e calcular a força contra eletromotriz da máquina em estudo, faz-se uma revisão sobre o Método da Permeabilidade Fixa, método este que permite a linearização do ponto de operação da máquina. Dessa forma, as simulações são conduzidas por meio do método dos elementos finitos e do Método da Permeabilidade Fixa, levando-se em conta a forma de onda da corrente de alimentação. Atenção especial é dada ao modo que se analisa o fluxo concatenado e a forma de obtenção da força contra eletromotriz uma vez que as formas de onda do fluxo concatenado sofrem variações abruptas a cada 60º elétricos. Além destes parâmetros, analisa-se também cada uma das parcelas do torque eletromagnético, i.e., torque mútuo, torque de relutância e torque de borda, sendo realizado ao final do trabalho, uma comparação entre a soma da estimativa de cada parâmetro com o valor do torque eletromagnético obtido por meio de uma simulação não linear. / This work deals with the assessment of a surface mounted magnet synchronous machine\'s parameters (whose back-EMF is approximately trapezoidal) and that is fed by an ideal square current waveform. In order to investigate and describe each machine\'s parameter, a review on Frozen Permeability Method is presented. Some simulation by means of finite element method with the aid of Frozen Permeability Method are carried out taking into account that the machine is fed by an ideal square current waveform. The results for flux-linkage wave-form and back-EMF waveform are shown and analyzed. A special attention is given to back-EMF calculation since the linkage flux of each phase has an abrupt change every sixty electrical degrees due to the phase commutation. In addition, an attention is given to each torque component on load condition, i.e., mutual torque, reluctance torque, cogging torque and a comparison between the electromagnetic torque and the summation of these components.
12

Controle preditivo Finite Control-Set aplicado à máquina síncrona com ímã permanente no rotor / Finite Control-Set predictive control of permanent magnet synchronous machine

Allan Gregori de Castro 20 February 2017 (has links)
Ondulações de torque devido à comutação de fases é apontada como a principal desvantagem do método de controle 6 pulsos convencional do motor síncrono de ímã permanente no rotor com força contra-eletromotriz trapezoidal. Para reduzir essas ondulações, diferentes estratégias de controle vetorial dessa máquina são apresentadas na literatura. Nesse trabalho é proposto e analisado o controle vetorial dessa máquina utilizando uma malha de controle de corrente baseada no Finite Control-Set Model-based Predictive Control (FCS-MPC). Como resultado, a estrutura de controle vetorial proposta é capaz de reduzir as ondulações de torque de comutação e também aquelas provenientes de imperfeições da força contraeletromotriz trapezoidal. Esse resultado é atingido sem a alteração da estrutura do conversor, adição de circuito ou alteração na tensão de barramento. Em termos de desempenho dinâmico, são demonstradas a rápida dinâmica de torque sem necessidade de sintonia ou projeto de ganhos de controlador e dinâmica desacoplada das variáveis de controle sem necessidade de cálculo de termos de desacoplamento. Esses resultados apontam vantagens sobre recentes propostas na literatura baseada em controladores lineares. Também é implementado uma estratégia de melhoria de desempenho do FCS-MPC baseado na inclusão do conceito de ciclo de trabalho. Essa abordagem permite reduzir significativamente, em baixa velocidade, a banda de ondulação da corrente de estator e torque da máquina, demonstrando uma melhoria em relação ao FCS-MPC sem ciclo de trabalho. / Torque ripples due to phase commutation are pointed to the main drawback of 120 degree 6 step control of synchronous motor with trapezoidal back electromotive force (back EMF). To reduce these ondulations, different vector control strategies are presented in the literature. This study proposes and analyzes the application of the Finite Control-Set Model-based Predictive Control in the current loop of vector control strategy of permanent magnet synchronous motor with trapezoidal back EMF. As a result, the control structure reduces the torque ripple comming from phase commutation and back EMF shape imperfections. This result is achieved without changing the converter topology, the DC link voltage or including aditional circuit. Concerning to dynamic response, the proposed control strategy offers fast torque dynamics without gain tunning needed and decoupled dynamic of variable control. Furthermore, it is implemented an improvement approach to FCS-MPC based on duty-cycle concept. This strategy reduces significantly the torque ripple in low speed range, demonstrating an advance over conventional FCS-MPC.
13

Controle preditivo Finite Control-Set aplicado à máquina síncrona com ímã permanente no rotor / Finite Control-Set predictive control of permanent magnet synchronous machine

Castro, Allan Gregori de 20 February 2017 (has links)
Ondulações de torque devido à comutação de fases é apontada como a principal desvantagem do método de controle 6 pulsos convencional do motor síncrono de ímã permanente no rotor com força contra-eletromotriz trapezoidal. Para reduzir essas ondulações, diferentes estratégias de controle vetorial dessa máquina são apresentadas na literatura. Nesse trabalho é proposto e analisado o controle vetorial dessa máquina utilizando uma malha de controle de corrente baseada no Finite Control-Set Model-based Predictive Control (FCS-MPC). Como resultado, a estrutura de controle vetorial proposta é capaz de reduzir as ondulações de torque de comutação e também aquelas provenientes de imperfeições da força contraeletromotriz trapezoidal. Esse resultado é atingido sem a alteração da estrutura do conversor, adição de circuito ou alteração na tensão de barramento. Em termos de desempenho dinâmico, são demonstradas a rápida dinâmica de torque sem necessidade de sintonia ou projeto de ganhos de controlador e dinâmica desacoplada das variáveis de controle sem necessidade de cálculo de termos de desacoplamento. Esses resultados apontam vantagens sobre recentes propostas na literatura baseada em controladores lineares. Também é implementado uma estratégia de melhoria de desempenho do FCS-MPC baseado na inclusão do conceito de ciclo de trabalho. Essa abordagem permite reduzir significativamente, em baixa velocidade, a banda de ondulação da corrente de estator e torque da máquina, demonstrando uma melhoria em relação ao FCS-MPC sem ciclo de trabalho. / Torque ripples due to phase commutation are pointed to the main drawback of 120 degree 6 step control of synchronous motor with trapezoidal back electromotive force (back EMF). To reduce these ondulations, different vector control strategies are presented in the literature. This study proposes and analyzes the application of the Finite Control-Set Model-based Predictive Control in the current loop of vector control strategy of permanent magnet synchronous motor with trapezoidal back EMF. As a result, the control structure reduces the torque ripple comming from phase commutation and back EMF shape imperfections. This result is achieved without changing the converter topology, the DC link voltage or including aditional circuit. Concerning to dynamic response, the proposed control strategy offers fast torque dynamics without gain tunning needed and decoupled dynamic of variable control. Furthermore, it is implemented an improvement approach to FCS-MPC based on duty-cycle concept. This strategy reduces significantly the torque ripple in low speed range, demonstrating an advance over conventional FCS-MPC.
14

Detecção de ilhamento em redes com geração distribuída por injeção de pequenos sinais na rede elétrica

Oliveira, Ramon Reis Siqueira de 18 December 2017 (has links)
Submitted by Geandra Rodrigues (geandrar@gmail.com) on 2018-03-27T15:28:12Z No. of bitstreams: 1 ramonreissiqueiradeoliveira.pdf: 4744081 bytes, checksum: dbce2e20c42a3bc456ad52a2096349ec (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2018-03-27T17:52:51Z (GMT) No. of bitstreams: 1 ramonreissiqueiradeoliveira.pdf: 4744081 bytes, checksum: dbce2e20c42a3bc456ad52a2096349ec (MD5) / Made available in DSpace on 2018-03-27T17:52:51Z (GMT). No. of bitstreams: 1 ramonreissiqueiradeoliveira.pdf: 4744081 bytes, checksum: dbce2e20c42a3bc456ad52a2096349ec (MD5) Previous issue date: 2017-12-18 / Uma rede com vários geradores distribuídos conectados pode melhorar a eficiência energética e reduzir o impacto negativo na rede elétrica. Um problema que surge é quando o fornecimento de energia principal é desconectado do sistema, diz-se então que ocorreu um ilhamento. Essa situação é indesejada, pois pode provocar problemas em termos de qualidade de energia, segurança, tensão e estabilidade de frequência. Esse trabalho tem por finalidade identificar o ilhamento pela variação da impedância do sistema, utilizando um método proposto que utiliza uma técnica de estimação de impedância através da injeção de um pequeno sinal na tensão de saída do gerador distribuído. Os testes realizados mostraram que quanto maior for a contribuição do inversor na potência fornecida para a carga, melhores são os valores estimados de impedância e na presença de dois inversores, os sinais injetados por cada um deles devem estar em frequências harmônicas o mais distante possível, para melhores resultados na estimação da impedância. Além disso, quando o fluxo de potência da rede para a carga é próximo de zero, o método foi capaz de identificar o ilhamento mesmo cosem atuação dos relés de tensão e frequência. O ilhamento é possível de ser identificado em aproximadamente 0,5 s em todos os casos testados, estando dessa forma dentro do tempo máximo estabelecido nas normas. / A grid with multiple distributed generators can improve energy efficiency and reduce the negative impact on itself. One problem that occurs is when the main power supply is disconnected from the system, this is called islanding. This is undesirable because it can cause problems in terms of power quality, safety, voltage and frequency stability. This work aims to identify the islanding by the system impedance variation, using a proposed method that uses an impedance estimation technique, injecting a small signal into the output voltage of the distributed generator. The tests performed showed as higher the contribution of the inverter to the power supplied to the load as better the estimated impedance values. In the presence of two inverters, the signals injected by each of them must be in harmonic frequencies, for better impedance estimation results. In addition, when the utility energy flow to the load is close to zero, the method was able to identify the same island as the voltage and frequency relays. The island can be identified in approximately 0.5 s in all cases tested, thus being within the maximum time limit set in the standards.
15

Análise da estabilidade de sistemas de potência via ATP e comparação dos resultados com o PSAT / Power system stability analysis using ATP and comparison of results with PSAT

Ferreira, Gislene Cristiane de Lima 20 September 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This study had as main objective to perform the modeling and analysis of transient stability of a typical electric power system. The second goal, also important, was to assess the feasibility of using ATP (Alternative Transients Program) as a computer tool for simulation of transient stability. The system focused here is comprised of nine busses with three generators, one hydraulic and the other two with thermal characteristics. All the system machines were equipped with voltage regulators and speed governor in ATP software. The technical issues studied here refer to the analysis of system stability after a disturbance, such as: three-phase short-circuit, load loss and generation outage. The results show that ATP software performs satisfactorily the transient stability analysis. This fact can also be proved by comparing the results obtained from ATP with those from simulations with PSAT (Power System Analysis Toolbox). For this purpose some adjustments were necessary in the graphical results since ATP works in time domain while PSAT program operates in the frequency domain. / Este trabalho teve como principal objetivo realizar a modelagem e a análise da estabilidade transitória de um sistema elétrico de potência típico. O segundo objetivo, também importante, consistiu em avaliar a viabilidade de se utilizar o ATP (Alternative Transients Program) como uma ferramenta computacional para simulação de estabilidade transitória. O sistema aqui enfocado é composto por nove barramentos com três unidades geradoras, uma com característica hidráulica e as outras duas com características térmicas. Todas as máquinas do sistema foram equipadas com reguladores de tensão e velocidade no programa ATP. As questões técnicas estudadas aqui se referem à análise da estabilidade do sistema após uma perturbação, sendo elas: falta trifásica, perda de carga e saída de geração. Os resultados mostram que o software ATP realiza satisfatoriamente a análise de estabilidade transitória. Este fato pode também ser comprovado pela comparação dos resultados obtidos com o ATP com aqueles provenientes de simulações com o PSAT (Power System Analysis Toolbox). Para este propósito foi necessário realizar alguns ajustes nos resultados gráficos já que ATP trabalha no domínio do tempo enquanto que o programa PSAT opera no domínio da frequência, tais como: transformação de alguns gráficos fornecidos pelo ATP em pu. / Mestre em Ciências
16

Controle sem sensores mecânicos para gerador síncrono a ímã permanente / Sensorless control of permanent magnet synchronous generator

Bernardes, Thiago Araújo 29 July 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Thesis proposes sensorless vector control schemes that combine designed observers in the discrete-time domain to estimate the rotor position and speed for a permanent magnet synchronous generator of non-salient poles. Two control schemes are proposed. The first scheme is based on a discrete sliding mode current observer in series with an adaptive electromotive force observer. Then, the sliding conditions that assure the sliding motion around the sliding surface are derived to ensure the stability of the current observer as well as an innovative design procedure is proposed for it. Moreover, the electromotive force observer is designed using Lyapunov s Discrete Direct Method, which provides the estimated rotor position and speed. The second scheme extends the developed methodology for the former, considering the parametric uncertainties and eliminating the high frequency components of chattering. The second scheme uses a discrete sliding mode current observer as in the first scheme. However, the electromotive force observer is replaced by a phase-locked loop in series with a discrete sliding mode robust differentiator, which follows the proposed methodology for the discrete sliding mode current observer. Experimental results validate the theoretical analysis and demonstrate the performance of the proposed control schemes considering a small scale wind energy conversion system. In addition, proposed schemes are compared with others of the literature. It should be noticed that the whole approach is carried out in discrete time domain making it suitable for a microcontroller or digital signal processor implementation. / Esta Tese propõe esquemas de controle vetorial sem sensores mecânicos de posição e de velocidade que combinam observadores projetados no domínio de tempo discreto para estimar essas variáveis para um gerador síncrono a ímãs permanentes de polos não salientes. Dois esquemas de controle são propostos. O primeiro esquema baseiase em um observador de corrente por modos deslizantes discretos em série com um observador adaptativo de força eletromotriz. Então, as condições de deslizamento que asseguram os modos deslizantes em torno da superfície de deslizamento são estabelecidas no domínio de tempo discreto para garantir a estabilidade do observador de corrente e um inovador procedimento de projeto para ele é proposto. Em seguida, o observador de força eletromotriz é projetado usando o método direto de Lyapunov discreto, que fornece a posição e a velocidade rotóricas estimadas. O segundo esquema estende a metodologia desenvolvida para o primeiro, considerando as incertezas paramétricas bem como eliminando as componentes de alta frequência de chattering. O segundo esquema usa um observador de corrente por modos deslizantes discretos como o primeiro. Entretanto, o observador de força eletromotriz é substituído por um retentor de fase em série com um diferenciador robusto por modos deslizantes discretos, que segue a metodologia proposta para o observador de corrente. Resultados experimentais validam a análise teórica desenvolvida e demonstram o desempenho dos esquemas de controle propostos considerando um sistema de conversão de energia eólica de pequeno porte. Além disso, os esquemas propostos são comparados com outros da literatura. Ressalta-se que a toda abordagem é desenvolvida no domínio de tempo discreto tornando-a apta para uma implementação em microcontroladores e em processadores digitais de sinais.
17

Estudos de desempenho dinâmico de geradores síncronos de produtores independentes em sistemas de geração distribuída via ATPDraw / Dynamic performance studies of synchronous generators of independent producers in distributed generation systems via ATPDraw

Peres, Larissa Marques 19 July 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work aims to analyze the dynamic performance of a synchronous generator and its controls in a distributed generation system, as well as evaluate the impacts of its operation when connected to the distribution grid, using for this task the ATPDraw interface/tool of software ATP. Within this context, it is firstly necessary to obtain suitable models to represent the synchronous machine control systems (voltage regulator, speed governor and stabilizer system) in ATPDraw. Furthermore, for stability analysis, it is developed a mathematical technique to calculate the machine power angle which is represented in ATPDraw by a device (icon). The adjustments of voltage and speed control system parameters are performed by some adopted procedures which are verified using two electric systems: the first one with a synchronous generator connected to the distribution grid; and the second with three distinct generators forming a multimachine system. In these systems some disturbances are applied such as load shedding and short-circuit to accomplish the studies. Finally, with the previous results, it is carried out some dynamic performance studies of a synchronous generator of an independent producer connected to a distribution grid so as to assess aspects of power quality (voltage magnitude), stability and to evaluate the influence of machine controls during the system response for a given load shedding. / Este trabalho tem como objetivo analisar o desempenho dinâmico de um gerador síncrono e seus controles, num sistema de geração distribuída, assim como avaliar os impactos causados por este quando da sua operação conectado às redes de distribuição, utilizando a interface ATPDraw do software ATP. Neste contexto, é primeiramente necessário obter modelos adequados para representar os sistemas de controle da máquina síncrona (regulador de tensão e regulador de velocidade e estabilizador do sistema) no ATPDraw. Além disso, para análise de estabilidade é desenvolvido uma técnica matemática para o cálculo do ângulo de potência da máquina a qual é representada no ATPDraw por um dispositivo (ícone). Para ajustar os parâmetros dos sistemas de controle de tensão e de velocidade são apresentados alguns procedimentos adotados, sendo estes verificados por meio de dois sistemas elétricos: o primeiro com um gerador síncrono conectado a uma rede de distribuição; e o segundo composto por três geradores distintos formando um sistema multimáquinas. Nesses sistemas são aplicados distúrbios do tipo rejeição de carga e curto-circuito para realização dos estudos. Finalmente, com os resultados obtidos anteriormente, são realizados estudos do desempenho dinâmico de um gerador síncrono de um produtor independente, conectado a rede de distribuição, para avaliar aspectos de qualidade de energia (magnitude de tensão), de estabilidade e verificar as influências dos controles da máquina durante a resposta do sistema para uma dada rejeição de carga. / Mestre em Ciências

Page generated in 0.087 seconds