Spelling suggestions: "subject:"macrófagos aquáticos flutuante"" "subject:"macrófagos aquáticos flutuação""
1 |
Estudo de bioacumulação de metais tóxicos e elementos traço em amostras de macrófitas aquáticas flutuantes do Reservatório Guarapiranga, São Paulo - SP, Brasil / Bioaccumulation of toxic elements in floating aquatic macrophytes of Guarapiranga Reservoir, São Paulo - SP, BrazilCoutinho, Suellen Nobrega 06 February 2018 (has links)
As macrófitas desempenham um papel de extrema relevância em ambientes aquáticos, pois acumulam elementos metálicos e podem ser utilizadas para biomonitoramento desses ecossistemas, principalmente quando se trata de um importante reservatório para abastecimento público de água, assim como o Reservatório Guarapiranga. Neste estudo, foram avaliados os teores dos elementos potencialmente tóxicos As, Cd, Cr, Cu, Hg, Ni, Pb e Zn e outros elementos de interesse, em amostras de quatro espécies de macrófitas flutuantes (E. crassipes, P. stratiotes, S. herzogii e S. molesta), e nos compartimentos ambientais sedimentos e água. Foram coletadas amostras de macrófitas, sedimentos e água, em três pontos ao longo do Reservatório Guarapiranga em duas campanhas de coleta realizadas nas épocas chuvosa (março) e seca (setembro), em três semanas consecutivas para cada época de coleta, com o objetivo de avaliar a extensão da contaminação por elementos metálicos neste ecossistema. Para tal, foram aplicadas as seguintes técnicas analíticas: INAA, GF AAS, Análise Direta de Mercúrio, ICP OES e ICP MS para as análises das macrófitas e as técnicas ICP OES e CV AAS para as análises de água e sedimentos. Os resultados dos elementos tóxicos determinados nas macrófitas apresentaram valores acima dos valores de referência para plantas vasculares aquáticas para a maioria dos elementos, especialmente para o Cu, que apresentou teores extremamente elevados (10 a 802 mg kg-1), em especial no ponto P-03, onde foram encontradas as concentrações mais elevadas deste metal. A ANOVA mostrou diferenças estatisticamente significativas entre as concentrações nos locais de coleta, para a maioria dos elementos, porém não indicou diferenças estatisticamente significativas em relação ao acúmulo desses elementos entre as espécies de macrófitas flutuantes, em ambas as épocas (chuvosa e seca). Os teores dos elementos tóxicos determinados nas amostras de água mostraram-se abaixo dos limites de quantificação das técnicas analíticas aplicadas. No entanto, a avaliação das concentrações desses elementos nas amostras de sedimentos revelou valores que ultrapassaram os valores de TEL (Threshold Effect Level) para a maioria dos elementos analisados e os altos teores de Cu (32 a 4567 mg kg-1) ultrapassaram o valor de PEL (Probable Effect Level), especialmente no ponto P-03. O índice de geoacumulação demonstrou sedimentos de moderadamente a muito poluídos por Zn e de moderadamente a altamente poluídos por Cu. A contaminação de cobre no reservatório é explicada pela frequente aplicação deste metal na forma de sulfato de cobre, como algicida, em especial no ponto de coleta (P-03) que está localizado próximo ao local onde a Companhia de Saneamento Básico do Estado de São Paulo (SABESP) realiza a captação de água no reservatório. A comparação entre os teores dos elementos As, Cd, Cr, Cu, Hg, Ni, Pb e Zn analisados nas amostras de sedimentos e macrófitas apresentou uma correlação positiva, indicando a bioacumulação desses elementos pelas macrófitas. Os resultados podem indicar potencial risco da qualidade da água no reservatório. / Macrophytes play a relevant role in aquatic environments since they may accumulate metallic elements and can be an important tool for bioaccumulation studies, especially concerning an important and strategic water supply as Guarapiranga Reservoir. In this study, the contents of the potentially toxic elements As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, and other elements of interest, were determined in samples of four species of macrophytes (E. crassipes, P. stratiotes, S. herzogii e S. molesta), sediments and water samples, aiming to assess metallic elements contamination. Samples were collected at three sites of the Guarapiranga Reservoir, in two sampling campaigns on wet (March) and dry (September) seasons, in three consecutive weeks for each season. The analytical techniques employed were: INAA, GF AAS, Mercury Direct Analysis, ICP OES and ICP MS, for macrophyte analysis, and ICP OES and CV AAS for sediment and water analysis. Toxic element concentration results in macrophytes presented higher values than reference values for aquatic plants for most elements, mainly for Cu, which presented extremely high values (10 to 802 mg kg-1), especially at site P-03, where the highest contents were observed. ANOVA showed significant differences among sampling sites. However, there were no significant statistical differences in the accumulation of the analyzed elements among the macrophyte species for both season campaigns (wet and dry). The toxic elements content in water samples were below the quantification limits of the analytical techniques applied. Nevertheless, the level of the toxic elements analyzed in sediment samples exceeded TEL values (Threshold Effect Level) for most elements. Besides, Cu presented high concentrations (32 a 4567 mg kg-1) that surpassed PEL value (Probable Effect Level), especially at site P-03. The geoaccumulation index indicated sediments moderate to highly polluted by Zn and moderate to extremely polluted by Cu. The contamination by Cu in the reservoir is explained by the frequent use of this metal as algicide (copper sulphate), especially at the site (P-03) located near the State Company of Water Supply (SABESP) catchment point. The results obtained for As, Cd, Cr, Cu, Hg, Ni, Pb and Zn in the sediment samples were compared to the results obtained for the macrophyte samples, and a positive correlation was obtained, indicating bioaccumulation of these elements in aquatic macrophytes. These results may indicate potential risk of the reservoir water quality.
|
2 |
Estudo de bioacumulação de metais tóxicos e elementos traço em amostras de macrófitas aquáticas flutuantes do Reservatório Guarapiranga, São Paulo - SP, Brasil / Bioaccumulation of toxic elements in floating aquatic macrophytes of Guarapiranga Reservoir, São Paulo - SP, BrazilSuellen Nobrega Coutinho 06 February 2018 (has links)
As macrófitas desempenham um papel de extrema relevância em ambientes aquáticos, pois acumulam elementos metálicos e podem ser utilizadas para biomonitoramento desses ecossistemas, principalmente quando se trata de um importante reservatório para abastecimento público de água, assim como o Reservatório Guarapiranga. Neste estudo, foram avaliados os teores dos elementos potencialmente tóxicos As, Cd, Cr, Cu, Hg, Ni, Pb e Zn e outros elementos de interesse, em amostras de quatro espécies de macrófitas flutuantes (E. crassipes, P. stratiotes, S. herzogii e S. molesta), e nos compartimentos ambientais sedimentos e água. Foram coletadas amostras de macrófitas, sedimentos e água, em três pontos ao longo do Reservatório Guarapiranga em duas campanhas de coleta realizadas nas épocas chuvosa (março) e seca (setembro), em três semanas consecutivas para cada época de coleta, com o objetivo de avaliar a extensão da contaminação por elementos metálicos neste ecossistema. Para tal, foram aplicadas as seguintes técnicas analíticas: INAA, GF AAS, Análise Direta de Mercúrio, ICP OES e ICP MS para as análises das macrófitas e as técnicas ICP OES e CV AAS para as análises de água e sedimentos. Os resultados dos elementos tóxicos determinados nas macrófitas apresentaram valores acima dos valores de referência para plantas vasculares aquáticas para a maioria dos elementos, especialmente para o Cu, que apresentou teores extremamente elevados (10 a 802 mg kg-1), em especial no ponto P-03, onde foram encontradas as concentrações mais elevadas deste metal. A ANOVA mostrou diferenças estatisticamente significativas entre as concentrações nos locais de coleta, para a maioria dos elementos, porém não indicou diferenças estatisticamente significativas em relação ao acúmulo desses elementos entre as espécies de macrófitas flutuantes, em ambas as épocas (chuvosa e seca). Os teores dos elementos tóxicos determinados nas amostras de água mostraram-se abaixo dos limites de quantificação das técnicas analíticas aplicadas. No entanto, a avaliação das concentrações desses elementos nas amostras de sedimentos revelou valores que ultrapassaram os valores de TEL (Threshold Effect Level) para a maioria dos elementos analisados e os altos teores de Cu (32 a 4567 mg kg-1) ultrapassaram o valor de PEL (Probable Effect Level), especialmente no ponto P-03. O índice de geoacumulação demonstrou sedimentos de moderadamente a muito poluídos por Zn e de moderadamente a altamente poluídos por Cu. A contaminação de cobre no reservatório é explicada pela frequente aplicação deste metal na forma de sulfato de cobre, como algicida, em especial no ponto de coleta (P-03) que está localizado próximo ao local onde a Companhia de Saneamento Básico do Estado de São Paulo (SABESP) realiza a captação de água no reservatório. A comparação entre os teores dos elementos As, Cd, Cr, Cu, Hg, Ni, Pb e Zn analisados nas amostras de sedimentos e macrófitas apresentou uma correlação positiva, indicando a bioacumulação desses elementos pelas macrófitas. Os resultados podem indicar potencial risco da qualidade da água no reservatório. / Macrophytes play a relevant role in aquatic environments since they may accumulate metallic elements and can be an important tool for bioaccumulation studies, especially concerning an important and strategic water supply as Guarapiranga Reservoir. In this study, the contents of the potentially toxic elements As, Cd, Cr, Cu, Hg, Ni, Pb, Zn, and other elements of interest, were determined in samples of four species of macrophytes (E. crassipes, P. stratiotes, S. herzogii e S. molesta), sediments and water samples, aiming to assess metallic elements contamination. Samples were collected at three sites of the Guarapiranga Reservoir, in two sampling campaigns on wet (March) and dry (September) seasons, in three consecutive weeks for each season. The analytical techniques employed were: INAA, GF AAS, Mercury Direct Analysis, ICP OES and ICP MS, for macrophyte analysis, and ICP OES and CV AAS for sediment and water analysis. Toxic element concentration results in macrophytes presented higher values than reference values for aquatic plants for most elements, mainly for Cu, which presented extremely high values (10 to 802 mg kg-1), especially at site P-03, where the highest contents were observed. ANOVA showed significant differences among sampling sites. However, there were no significant statistical differences in the accumulation of the analyzed elements among the macrophyte species for both season campaigns (wet and dry). The toxic elements content in water samples were below the quantification limits of the analytical techniques applied. Nevertheless, the level of the toxic elements analyzed in sediment samples exceeded TEL values (Threshold Effect Level) for most elements. Besides, Cu presented high concentrations (32 a 4567 mg kg-1) that surpassed PEL value (Probable Effect Level), especially at site P-03. The geoaccumulation index indicated sediments moderate to highly polluted by Zn and moderate to extremely polluted by Cu. The contamination by Cu in the reservoir is explained by the frequent use of this metal as algicide (copper sulphate), especially at the site (P-03) located near the State Company of Water Supply (SABESP) catchment point. The results obtained for As, Cd, Cr, Cu, Hg, Ni, Pb and Zn in the sediment samples were compared to the results obtained for the macrophyte samples, and a positive correlation was obtained, indicating bioaccumulation of these elements in aquatic macrophytes. These results may indicate potential risk of the reservoir water quality.
|
3 |
Estudo do potencial de biossorção dos íons Cd (II), Cu (II) e Zn (II) pela macrófita Eichhornia crassipes / Biosorption potential study of Cd (II), Cu (II) and Zn (II) by the macrophyte Eichhornia crassipesLavarda, Fábio Luciano 19 February 2010 (has links)
Made available in DSpace on 2017-07-10T18:08:13Z (GMT). No. of bitstreams: 1
Fabio Luciano Lavarda.pdf: 1286405 bytes, checksum: 6e333d013ea649c1abc83af92614fc90 (MD5)
Previous issue date: 2010-02-19 / The aim of this work was to evaluate the adsorption capacity of Eichhornia crassipes as well as to investigate on the adsorption equilibrium and kinetic of copper, cadmium and zinc divalent ions in single, binary and ternary sorption systems. In order to improve the biosorption kinetic and experimental equilibrium conditions, the temperature effect on the plant drying was tested in 30 and 50°C temperatures, while the solution temperature effect was evaluated at four controlled temperatures, ranging from 25 to 45°C. The biosorbent grain size effect was also studied, using three fractional grain sizes between 0.147 to 0.589 mm and their mixture as well. For all tests, a volume of 50 mL for metal solution (4 mEq.L-1) was added to 250 mg dry plant in 125-mL Erlenmeyer flask. The mixtures were shaken for 12 h for each temperature setting, and then, the quantity of metal in each filtrated liquid phase sample was measured by AAS. In order to obtain the equilibrium time, the adsorption experimental times were set up at several short contact times, ranging from 5 min to 48 h. On the other hand, several batch single metal sorption experiments using the E. crassipes biomass as biosorbent were also carried out using a constant volume of 50 mL metal-supplied solution (4.0 mEq.L-1) in contact with dry biomass, ranging from 20 to 550 mg. Similarly, batch multicomponent sorption experiments, with equals and different amounts of metals spiked in biosorption medium, were performed in pH 5, during a 4 h shaking time. Within the dry temperature range tested, a higher metal removal performance was achieved for a temperature of 30oC. In the interval from 25 to 45oC controlled temperatures, the highest metal removal percent was observed to occur at 30oC solution temperature. On the other hand, the metal-sorption experiments based on fractional biomass grain sizes (0.147-0.589 mm) have not shown significant differences on the metal ion removal as compared among a mixture of them and different grain sizes tested. The results of monocomponent kinetic tests have showed that the equilibrium time was achieved around 2 h, 1 h and 45 min for Zn(II), Cu(II) and Cd(II), respectively. However, 1 and 2 h equilibrium time was achieved for Zn(II) and Cd(II), respectively, in a Zn(II)-Cd(II) binary system. In similar way, 1 and 2 h equilibrium time was achieved for Cu(II) and Cd(II), respectively, in a Cu(II)-Cd(II) binary system, while it was 45 min for both Zn(II) and Cu(II) in a Zn(II)-Cu(II) binary system. From the ternary kinetic test, equilibrium time of 45 min was observed for both Zn(II) and Cd(II), while a 1h equilibrium time was observed for Cu(II). The kinetic experimental data, at 30oC and pH 5, were found to best follow the pseudo-second order kinetic model, according to the good correlation coefficient value. The single equilibrium data for each metal at pH 5 were described according to the Langmuir isotherm model, with the same maximum metal content (qmax) values around 0.6 mEq.g-1 for all metals. While, the binary sorption data were evaluated through the Langmuir-type isotherms surface and their adjustable parameters were determined by the PSO (Particle Swarm Optimization) method. From the modeling results of the binary sorption data, the maximum metal contents were: 0.49 and 0.21 mEq.g-1 for Zn(II) and Cu(II), respectively, in Zn(II)-Cu(II) system; 0.42 and 0.17 mEq.g-1 for Cu(II) and Cd(II), respectively, in Cu(II)-Cd(II) system; 0.46 and 0.17 mEq.g-1 for Zn(II) and Cd(II), respectively, in Zn(II)-Cd(II) system. While, the maximum metal content values of 0.27, 0.65 and 0.30 mEq.g-1 were obtained for Zn(II), Cu(II) and Cd(II) ions, respectively, for a ternary sorption system. The kinetic and equilibrium adsorption results suggest that the E. crassipes biomass can be used as a low-cost, alternative biosorbent in metal treatment systems of industrial effluents. / O objetivo deste trabalho foi avaliar a capacidade de adsorção da macrófita Eichhornia crassipes, bem como investigar o equilíbrio e a cinética de adsorção dos íons divalentes cobre, cádmio e zinco, em sistemas monocomponentes, binários e ternários de sorção. A fim de melhorar a cinética de biossorção e as condições experimentais de equilíbrio, foi testado o efeito da temperatura de secagem da planta utilizando as temperaturas de 30 e 50°C, enquanto que o efeito da temperatura de sorção foi avaliada em quatro diferentes temperaturas, variando de 25 a 45°C. O efeito do tamanho dos grânulos do biossorvente também foi estudado utilizando-se três granulometrias, as quais estavam na faixa entre 0,147 e 0,589 mm e também foi testada a mistura dos grânulos sem ser peneirada. Para todos os testes, um volume de 50 mL de solução contendo os íons metálicos (4 mEq.L-1) foi colocada em contato com 250 mg de biomassa em erlenmeyers de 125 mL. As misturas foram agitadas por 12 h para cada ajuste de temperatura e, em seguida, as amostras foram filtradas e as quantidades de íons metálicos presentes na fase líquida foram medidas por espectrofotometria de absorção atômica. A fim de obter os tempos de equilíbrio foram realizados experimentos de adsorção em uma faixa de tempo variando de 5 min a 48 h. Também foram realizados testes batelada dos dados de equilíbrio utilizando a biomassa da E. crassipes como biossorvente em um volume constante de 50 mL de solução de metal (4,0 mEq.L-1) em contato com a biomassa seca, variando de 20 a 550 mg. Da mesma forma foram realizadas as bateladas experimentais de adsorção multicomponente, em pH 5, durante 4 horas de agitação. A temperatura de secagem da macrófita que obteve um desempenho maior na remoção dos íons metálicos foi a de 30°C. Para as temperaturas de sorção testadas no intervalo de 25 a 45°C, a percentagem mais elevada de remoção dos metais foi observada em 30°C. Por outro lado, os experimentos de sorção em várias granulometrias (0,147 a 0,589 mm) não mostraram diferenças significativas na remoção dos íons metálicos em relação à mistura delas ou entre as diferentes granulometrias testadas. Os resultados dos testes cinéticos monocomponentes mostraram que o tempo de equilíbrio foi alcançado em torno de 2 h, 1 h e 45 min para Zn (II), Cu (II) e Cd (II), respectivamente. No entanto, no sistema binário Zn(II)-Cd(II), os tempos de equilíbrio foram 1 e 2 h para o Zn(II) e para o Cd(II), respectivamente. De maneira similar, tempos de equilíbrio de 1 e 2 h também foram alcançados para o Cu(II) e para o Cd(II), respectivamente, no sistema binário Cu(II)-Cd(II) e de 45 min para ambos os íons Zn(II) e Cu(II) no sistema binário Zn(II)-Cu(II). A partir do teste cinético ternário foi possível observar que o tempo de equilíbrio para os íons Zn(II) e Cd(II) foram de 45 min, enquanto que para o Cu(II) o tempo de equilíbrio foi de 1h. Os dados experimentais da cinética em 30°C e em pH 5 foram melhor ajustados pelo modelo cinético de pseudo-segunda ordem de acordo com o valor do coeficiente de correlação obtido. Os dados de equilíbrio foram melhor descritos pela isoterma de Langmuir em pH 5 para todos os íons metálicos, obtendo os valores das capacidades máximas de sorção (qmax) em torno de 0,6 mEq.g-1 para todos os metais. Os dados de sorção para os sistemas binários foram avaliados através das isotermas de superfície de resposta pelo modelo de Langmuir e os parâmetros ajustáveis foram determinados pelo método PSO (Particle Swarm Optimization). A partir dos resultados obtidos na modelagem dos dados binários as capacidades máximas de sorção dos íons metálicos foram: 0,49 e 0,21 mEq.g-1 para o Zn(II) e o Cu(II), respectivamente, no sistema binário Zn(II)-Cu(II); 0,42 e 0,17 mEq.g-1 para o Cu(II) e o Cd(II), respectivamente, no sistema Cu(II)-Cd(II) e 0,46 e 0,17 mEq.g-1 para o Zn(II) e o Cd(II), respectivamente, no sistema Zn(II)-Cd(II). Enquanto que, para os sistema ternário, as capacidades máximas de sorção foram de 0,27; 0,65 e 0,30 mEq.g-1 para o Zn(II), o Cu(II) e o Cd(II), respectivamente. Os resultados obtidos na cinética de adsorção e de equilíbrio sugerem que a biomassa da E. crassipes pode ser utilizada com um baixo custo e é um biossorvente alternativo para o uso em sistemas de tratamento de efluentes industriais.
|
4 |
Utilização da espectroscopia PIXE na avaliação do mecanismo de biossorção dos íons Cu²+, Zn²+ e Cd²+ pela macrófita Egeria densa / Study of biosorption mechanism of Cu²+, Zn²+ and Cd²+ by Egeria densa macrophyte using pixe spectroscopySantos, Gustavo Henrique Fidelis dos 16 February 2012 (has links)
Made available in DSpace on 2017-07-10T18:08:21Z (GMT). No. of bitstreams: 1
Gustavo H F dos Santos.pdf: 2924329 bytes, checksum: 74a03389110637af2cd08afee90b23ec (MD5)
Previous issue date: 2012-02-16 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The main objective of this study was to evaluate the types of biosorption mechanisms involved in the removal of copper, zinc and cadmium divalent ions by dead Egeria densa macrophyte biomass. Batch adsorption experiments, consisting of mixtures of 0.3 g biomass and 50 mL metal solution were performed at initial pH 5, and under constant temperature (50 oC) and shaking conditions. The PIXE analytical technique was applied to determine the metal concentration in aqueous and solid phases. All PIXE measurements were performed at the Ion Beam-based Material Analysis Laboratory of the Physics Institute of the São Paulo University. Preliminary to adsorption experiments, the point of zero charge assigned to E. densa biosorbent was determined to be at a 5.0-6.5 pH value range. From metal speciation diagrams, the Cu, Zn, Cd and Ca divalent ions are expected to be majorities below the pH values of 5, 6, 8, and 10, respectively, whereas above these pH regions other metal compounds are mainly expected. As confirmed by measured pH values of 5.0 ± 0.2 at all experiments of adsorption and desorption, E. densa biosorbent submerged in each metal solution has exhibited zero net electrical charge on its surface, indicating that the removals of Cu²+, Zn²+, and Cd²+ and the desorption of these metal ions should be mainly performed by the ion exchange mechanism. According to the mass balance analysis performed for each metal adsorption experiment, the ion exchange process was confirmed to be the main mechanism for the metal removal and desorption by the E. densa biosorbent. At pH value of 5 the E. densa biosorbent surface shows a behavior of ion exchanger. / O objetivo principal deste trabalho foi avaliar os mecanismos de biossorção envolvidos na remoção dos íons cobre, zinco e cádmio pela macrófita aquática Egeria densa inativa. Experimentos de sorção monocomponente foram realizados em sistema batelada, misturando 0,3 g do biossorvente com 50 mL de solução metálica, com pH inicial 5,0, sob agitação constante e temperatura controlada em 30°C, em uma incubadora refrigerada com agitação. A determinação da concentração das espécies iônicas nas fases líquida e sólida foi realizada pela técnica espectroscópica PIXE (Particle Induced X-ray Emission). As medidas foram realizadas no Laboratório de Análise de Materiais por Feixes Iônicos do Instituto de Física da USP. Foram realizados experimentos para determinação do ponto de carga zero (pHPCZ) da biomassa e elaborados diagramas de especiação dos metais. O pHPCZ da macrófita Egeria densa foi encontrado na faixa entre 5,0 a 6,5. Por meio de diagramas de especiação, observou-se que as formas iônicas Cu²+, Zn²+, Cd²+ e Ca²+ são predominantes nas faixas de pH entre 0 - 5,0; 0 - 5,0; 0 - 8,0 e 0 - 10,0, respectivamente. O pH final medido em todos experimentos de biossorção e de regeneração da biomassa, foi em média de 5,0 ± 0,2. Desta forma, nos experimentos de sorção, os íons cobre, zinco, cádmio e cálcio encontravam-se na forma divalente. Nas condições operacionais utilizadas, a biossorção dos íons metálicos cobre, cádmio e zinco, pela macrófita Egeria densa, em pH inicial 5,0, ocorreu principalmente pelo mecanismo de troca iônica, com os cátions cálcio, sódio e potássio. Na regeneração da macrófita utilizando solução de CaCl2, também foi verificado que o mecanismo envolvido neste processo foi de troca iônica. O processo de dessorção dos íons metálicos ocorreu, devido ao comportamento da biomassa ser equivalente a de um trocador iônico.
|
5 |
Uso de duas espécies de macrófitas aquáticas, Eichhornia crassipes e Pistia stratiotes em tratamento de resíduos de cervejaria na cidade de Toledo/PR / Use of two species of aquatic macrophytes Eichhornia crassipes and Pistia stratiotes for treatment of waste brewery in the city of Toledo / PRSales, Cristina Viana 23 August 2011 (has links)
Made available in DSpace on 2017-07-10T18:13:31Z (GMT). No. of bitstreams: 1
Cristina Viana Sales.pdf: 1033711 bytes, checksum: 66526bf26f60f186b7ec4f4ca78473c3 (MD5)
Previous issue date: 2011-08-23 / The accumulation and deposition of high concentrations of organic matter cause the eutrophication of aquatic environments, and a sustainable alternative to the removal of these compounds is phytoremediation. This study evaluated the potential of two floating aquatic macrophytes, Eichhornia crassipes and Pistia stratiotes in the treatment of brewery wastewater. The treatment system consisted of eight experimental units, and the experimental design 2 treatments and 4 pseudoréplicas, each treatment was coupled to a mechanical filter in closed circulation system. We analyzed the parameters temperature, electrical conductivity, pH, dissolved oxygen, turbidity, COD, total phosphorus, nitrogen, nitrite and nitrate, and measure the biomass of macrophytes, the experiment lasted 21 days, with collections made weekly. Statistical analysis showed no statistical difference between treatments for the reduction of nutrients, however the two species E. crassipes and P. statiotes been proven effective in removing these nutrients. As for weight gain, E. crassipes had a higher growth compared to P. stratiotes. The use of phytoremediation is recommended for the treatment of brewery effluents due to low cost, easy maintenance and efficiency of aquatic macrophytes in removing nutrients that cause eutrophication of aquatic environments. / O acúmulo e deposição de elevadas concentrações de matéria orgânica provocam a eutrofização de ambientes aquáticos, e uma alternativa sustentável para a retirada destes compostos é a fitorremediação. Neste estudo avaliou-se o potencial de duas espécies de macrófitas aquáticas flutuantes, Eichhornia crassipes e Pistia stratiotes, no tratamento de efluente de cervejaria. O sistema de tratamento foi constituído de 8 unidades experimentais, sendo o delineamento experimental de 2 tratamentos com 4 pseudoréplicas, cada tratamento foi acoplado a um filtro mecânico, em sistema de circulação fechado. Foram analisados as variáveis temperatura, condutividade elétrica, pH, oxigênio dissolvido, turbidez, DQO, fósforo total, nitrogênio, nitrito e nitrato, e medida a biomassa das macrófitas aquáticas, o experimento teve duração de 21 dias, sendo as coletas feitas semanalmente. O estudo estatístico mostrou que não houve diferença estatística entre os tratamentos quanto à redução de nutrientes, no entanto as duas espécies E. crassipes e P. statiotes se mostraram eficazes na remoção desses nutrientes. Quanto ao ganho de peso, E. crassipes teve maior crescimento comparado a P. stratiotes. O uso da fitorremediação é recomendável para o tratamento de efluentes de cervejaria devido ao baixo custo, a fácil manutenção e a eficiência das macrófitas aquáticas na remoção de nutrientes que causam a eutrofização de ambientes aquáticos.
|
Page generated in 0.1232 seconds