21

Estudo clínico de prevalência de sinais e sintomas de disfunções craniomandibulares e contatos oclusais cêntricos em pacientes portadores de lesão labiopalatal /

Silva, Regina Célia Santos Pinto. January 1992 (has links)
Orientador: Marco Antonio Bottino / Banca: Celso Luiz de Angelis Porto / Banca: Maria Amélia Máximo de Araújo / Resumo: Foi realizado um estudo em onze pacientes portadores de lesão labiopalatal, quanto a prevalência de sinais e sintomas de disfunções craniomandibulares, associada ao número e distribuição dos contatos oclusais cêntricos, através de questionário, exame clínico e exame dos modelos dos pacientes montados em articulador semi-ajustável, em posição de máxima intercuspidação. Com relação aos sinais e sintomas, os mais frequentes foram ruído articular e sensibilidade à palpação do músculo lateral, seguidos por limitação de abertura e sensação de cansaço. Quanto aos contatos oclusais, o número foi muito reduzido (cerca de 5 contatos por pacientes, em média) e a localização foi considerada atípica pois em 62% dos casos o contato ocorreu em plano inclinado, o que sugere instabilidade oclusal. Foi baixa a frequência dos sinais e sintomas encontrados e todos considerados suaves. Os três sinais mais comuns de disfunções craníomandibulares (ruído articular, sensibilidade muscular à palpação e limitação de abertura) estavam presentes em apenas um dos casos / Abstract: A clinical investigation was undertaken to find out the prevalence of craniomandibular signs and symptoms in a group of 11 patients with labiopalatal lesions. The number and distribution of occlusal contacts was evaluated through questionnaire, clinical examination and analysis of mounted casts in partially adjustable articulators in the position of maximum inter cuspation. The most frequent signs and symptoms were articular sounds and lateral pterygoid muscle tenderness to palpation followed by restriction of mouth opening and sensation of tiredness. The number of occlusal contacts was small, mean of 5 contacts per patient, and the site was considered as atypical, 62% of them were on inclined plane surfaces , suggesting occlusal instability. The frequency of signs and symptoms was low and they were of a mild character. The most prevailing signs of craniomandibular dysfunction - articular sounds, muscular tenderness to palpation and restriction of mouth opening - was noticed in only one of the patients / Mestre
22

Influência do intemperismo natural ou induzido sobre a estabilidade cromática de próteses faciais, em função do material de confecção e da pigmentação /

Santos, Daniela Micheline dos. January 2008 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Alício Rosalino Garcia / Banca: Mário Alexandre Coelho Sinhoreti / Resumo: O maior problema enfrentado pelo protesista bucomaxilofacial é reproduzir a cor exata da pele do paciente, proporcionando uma estética agradável. Para alcançar este objetivo, o profissional deve ter materiais que possibilitem uma fácil caracterização, mantendo por um longo período de tempo a cor obtida. O propósito do presente estudo foi avaliar a estabilidade de cor de resinas acrílicas (Rapidaflex, Lentaflex e Resina Acrílica Termopolimerizável incolor e pigmentada) e de um silicone (Silastic MDX4-4210 incolor e com pigmentação) utilizados na confecção de próteses faciais, submetidos ao intemperismo natural ou artificial. Foram confeccionados 120 corpos-de-prova distribuídos em doze grupos. Metade dos corpos-de-prova foram submetidos ao envelhecimento natural por 180 dias, e a outra metade ao envelhecimento acelerado por 1008 horas. A alteração cromática dos corpos-de-prova foi verificada por meio da análise visual e da espectrofotometria de reflexão (Shimadzu, Kyoto, Japão). Os resultados foram submetidos à análise estatística pelos testes de Variância (ANOVA) de dois fatores e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica e visual que, independente do tipo de envelhecimento, ocorreu alteração de cor, estatisticamente significativa, entre alguns materiais. Os corpos-de-prova submetidos ao envelhecimento natural apresentaram maiores valores de alteração de cor do que aqueles submetidos ao envelhecimento acelerado. Todos os materiais sofreram alteração cromática pela influência da exposição ao meio ambiente ou pela ação do envelhecimento acelerado. / Abstract: The great problem that confronts the maxillofacial prosthodontist is reproduces the accurate color of the patient's skin, providing a satisfactory esthetic. Attempt to reach this purpose; the clinician should have materials to make an easy characterization, keeping the color by the time. The aim of this study was to evaluate the color stability of acrylic resins (Rapidaflex, Lentaflex and heat-cured colorless and pigmented acrylic resins) and a silicone (colorless and pigmented Silastic MDX4-4210) used to the confection of facial prostheses, submitted to natural or artificial weathering. 120 samples were made and distributed in twelve groups. 60 samples were submitted to the natural aging by 180 days, and the other half were submitted to the accelerated aging by 1008 hours. The chromatic differences were verified by means of the visual analysis and reflection spectrophotometer (Shimadzu, Kyoto, Japan). The results were analyzed by two-way analysis of variance (ANOVA) and Tukey tests (P<0,05). Color changes, between some materials, were observed by spectrophotometer and visual analysis, independently of the type of aging; it was statistically significant. The samples submitted to the natural aging showed higher values than the samples submitted to the accelerated aging. All materials suffered chromatic differences because to the environment exposure or the accelerated aging. / Mestre
23

Protese ocular individualizada em resina acrílica com esfera oca /

Oliveira, Simone Helena Gonçalves de. January 1995 (has links)
Orientador: Rolf Rode / Banca: Maria Cecília Montagna Rosé / Banca: Horácio Faig Leite / Resumo: A técnica proposta visa conseguir uma diminuição de peso das próteses oculares individualizadas amplas de resina acrílica, com passos laboratoriais simplificados. Para isso utilizaram-se esferas ocas pré fabricadas de material plástico, que são incluídas dentro da esclera. Compararam-se os pesos médios de escleras maciças convencionais (5,30g) com os de escleras com esferas ocas pré-fabricadas de material plástico (3,91g), respectivamente. A redução de peso foi significante com intervalo de confiança de 95% pelo teste "t " de "Student". Foi também executada a técnica, a título de ilustração, em pacientes do Ambulatório da Disciplina de Prótese Buco-Maxilo-Facial da Faculdade de Odontologia do Câmpus de São José dos Campos-Unesp, tendo cada paciente recebido uma prótese maciça e uma prótese com esfera oca pré-fabricada de material plástico. Concluiu-se que as próteses e as escleras que possuem no seu interior a esfera oca pré-fabricada de material plástico são mais leves que as escleras maciças e que a técnica é viável para cavidades anoftálmicas amplas e é praticada em poucas sessões / Abstract: The technique proposed aims at reducing the weight of individualized ample ocular prostheses using acrylic resins as well as simplifying laboratory procedure. For that, prefabricated hollow spheres made of plastic material, were inserted in the sclera. The average weights of the solid conventional sclera (5.30g) and those of the respective prefabricated plastic ones (3.91g) were compared. The weight reduction was significative with a confidence interval of 95% by the "Student" "t" test. ln addition, for illustration purpose, the technique was applied to patients in the ward of the Maxillofacial Prostheses Dicipline of the Dentistry School in the Campus of São José dos Campos - UNESP, having each patient received a solid prosthesis and a hollow prefabricated one made of plastic material. It has been concluded that the prostheses material spheres were inserted are lighter than the ones which received solid spheres; furthermore, thr technique is viable for ample anophtalmic cavities and requires few sessions / Mestre
24

Efeito da desinfecção química e do envelhecimento acelerado sobre a estabilidade dimensional, reprodução e manutenção de detalhes e estabilidade de cor do silicone facial Silastic MDX 4-4210 com opacificador /

Haddad, Marcela Filié. January 2010 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Aline Úrsula Rocha Fernandes / Resumo: Este estudo teve como objetivo avaliar a estabilidade dimensional, reprodução de detalhes e estabilidade de cor de silicone facial, com adição ou não de pigmento e opacificador; sob influência da desinfecção química e do envelhecimento acelerado. Para isso, foram obtidas 120 amostras, utilizando o silicone Silastic MDX 4-4210, divididas em 4 grupos contendo 30 amostras cada, sendo GI - incolor, GII - pigmentado com pó de cerâmica, GIII - com adição de sulfato de bário (opacificador) e GIV- pigmentado com pó de cerâmica e sulfato de bário. Dez amostras de cada grupo foram desinfetadas com uma das três substâncias a seguir: pastilhas efervescentes a base de peróxido alcalino, sabão neutro ou clorexidina. O processo de desinfecção química foi realizado três vezes por semana, durante 60 dias. Após esse período, todas as amostras foram submetidas ao envelhecimento acelerado. Os testes de estabilidade dimensional, reprodução de detalhes e estabilidade de cor foram realizados no período inicial, após 60 dias de desinfecção e, nos intervalos de 252, 504 e 1008 horas de envelhecimento acelerado. As amostras foram analisadas em computador pelo sistema AutoCAD para verificação da alteração dimensional linear; e observadas em lupa estereoscópica para a análise da reprodução de detalhes. A estabilidade de cor foi verificada por meio de espectrofotometria de reflexão. Os valores obtidos nos testes de estabilidade dimensional e estabilidade cromática foram submetidos à análise de variância e teste de Tukey (p<0,05). Para a análise da reprodução e manutenção de detalhes foi utilizado escore de 0 a 2. O fator desinfecção não influenciou estatisticamente nos valores de estabilidade dimensional, reprodução de detalhes e estabilidade de cor do silicone, independente da... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the dimensional stability, reproduction and maintenance of details and color stability of facial silicone, with different pigmentation, on the influence of the disinfection and accelerated aging. 120 samples were obtained, using Silastic MDX 4-4210 elastomer, divided in 4 groups with 30 samples: GI - colorless, GII - pigmented with ceramics, GIII - pigmented with barium sulfate opacifier, and GIV - pigmented with ceramics and barium sulfate opacifier. Ten samples of each group was submitted to the disinfection with effervescent tablets, with neutral soap or 4% chlorhexidine, three times a week during 60 days. After this period all samples were taken to a chamber of accelerated aging for not metallic bodies. The tests of dimensional stability, maintenance of the details, and color stability were realized after the confection, disinfection and in the intervals of each cycle of accelerated aging (252, 504 e 1008 hours). Samples were analyzed, in computer by the AutoCAD system to verification of the linear dimensional alteration and observed, in stereoscopic magnifying glass for analysis of the reproduction of details. The color stability was analyzed by means of spectrophotometer. The dimensional alteration and color stability values had been submitted to the analysis of variance and Tukey test (p<0.05). For the analysis of detail reproduction, the 0 -2 scores were used It can be observed that the factor: chemical disinfection had no influenced statistically on dimensional stability, detail reproduction and color stability values. Accelerated aging had influenced statistically on dimensional stability values after 1008 hours. About detail reproduction, all samples exhibited score 2 for all analyzed periods. Pigment and opacifier association was more stable for chromatic stability test in all analyzed... (Complete abstract, click electronic address below) / Mestre
25

Towards developing CAD/CAM solutions in the retention of extra-oral facial prosthetics

Daniel, Steffan John Rhys January 2014 (has links)
In the production of removable facial prosthetics, Computer-Aided Design and Manufacture (CAD/CAM) is being increasingly explored. This PhD thesis investigates the application of CAD/CAM in the design and production of components that retain the prostheses to the anatomy. Conventional methods of hand-crafting the retention elements are well established but little research has considered producing these elements using CAD/CAM. A fully digital prosthetic workflow has not yet been developed, and the efficacy of using CAD/CAM for retention mechanism design and fabrication remains unclear. This study firstly focuses on defining the requirements for designing extra-oral prosthesis retention mechanisms, by mapping the various stages of conventional practice and obtaining the opinions of practicing clinicians. Secondly, the qualitative findings are applied to develop a fully CAD/CAM process using existing technologies. Scanning, reverse engineering, design and fabrication technologies are trialled and samples of bar-clip mechanisms are produced. The final stage focuses on developing objective methods to evaluate aspects of bar-clip design previously limited to subjective evaluation, and to make an initial comparison of conventional and CAD/CAM bar-clip mechanisms. This focuses on measuring surface and dimensional quality, accuracy of fit and clip retention forces. This study provides an increased knowledge-base of current prosthetic practice; CAD/CAM prosthesis production and evaluation methods; and insight into the attitudes of clinicians towards the integration & implementation of CAD/CAM. The thesis demonstrates that CAD/CAM can be used to design, produce, and integrate bar-clip retention mechanisms in all aspects of the prosthesis production workflow. Digital measurement methods allow an objective evaluation of the important aspects of bar-clip mechanism design, identifying a number of inaccuracies/design flaws that current evaluation techniques fail to identify. The study concludes that the overall CAD/CAM workflow is not yet appropriate for clinical practice but there is potential in the newly developed processes and this drives future work.
26

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Pinheiro, Juliana Barchelli 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
27

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Cobein, Marcus Vinicius 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
28

Correlação estrutura-propriedades de silicones para prótese facial - Efeitos da pigmentação e do envelhecimento / Correlation structure-properties of silicones for facial prosthesis - Effects of pigmentation and aging

Juliana Barchelli Pinheiro 13 April 2012 (has links)
Este estudo avaliou a dureza Shore A, alteração de cor, recuperação elástica e resistência ao rasgamento de um silicone experimental (Ortho Pauher - O), quando comparado a um silicone usado em reabilitações faciais (MDX 4-4210 - MDX), quando submetidos à pigmentação e envelhecimento e ainda, analisou a micro estrutura desses materiais. Para análise da alteração de cor e dureza foram obtidos 160 espécimes circulares (80/material); para os ensaios de recuperação elástica foram obtidos 200 espécimes cilíndricos (100/material) e para o ensaio de resistência ao rasgamento, foram confeccionados 200 espécimes em forma de calça (100/material). Metade dos espécimes recebeu pigmentação intrínseca e a outra metade, pigmentação intrínseca e extrínseca, por meio da adição de pó de maquiagem. Em seguida, foram distribuídos aleatoriamente em três grupos de envelhecimento: 1 termociclagem (T), 2 - luz ultravioleta (UV) e 3 - luz natural (LN). O envelhecimento simulou um período de uso de um ano. Como controle (C), os espécimes foram mantidos em um recipiente fechado e na ausência total de luz por um ano. Para as análises micro estruturais, três espécimes de cada grupo foram submetidos à Microscopia Eletrônica de Varredura (MEV), Espectroscopia no Infravermelho (EI), Calorimetria Exploratória Diferencial (DSC) e Termogravimetria (TG). Os dados foram submetidos à Análise de variância e Teste Complementar de Tukey (p<0,05). Os resultados das análises micro estruturais foram apresentados em tabelas e gráficos. Para alteração de cor, não houve diferença entre os materiais e pigmentação. Os envelhecimentos por UV, LN e T promoveram a maior alteração. O MDX apresentou alterações em função da PIE, T e UV e o Ortho Pauher, em função da PI/UV e PIE/T e UV. Para a dureza, o silicone Ortho e a PI apresentaram as maiores alterações, bem como a LN e a UV. Ambos os materiais variaram em função das pigmentações e envelhecimento. Para resistência ao rasgamento houve diferença para todos os fatores e para a interação. O silicone O e a PI promoveram as menores médias. O MDX sofreu alteração em função da pigmentação e do envelhecimento. Na recuperação elástica, o material M apresentou a maior média, bem como o grupo PIE. Para o envelhecimento, a UV resultou em menor recuperação e os maiores valores foram encontrados no C e LN. Os dois materiais variaram em função da pigmentação e envelhecimento. As análises micro estruturais demonstraram que a polimerização dos materiais foi completa e que os pigmentos adicionados, nas proporções utilizadas, não influenciaram na estabilidade dos materiais. O resultado do estudo sugere que as alterações encontradas nas propriedades físico-mecânicas, em função da exposição às diferentes pigmentações e envelhecimento não representam diferenças estruturais importantes e que o silicone experimental merece estudos com vistas em sua aplicabilidade clínica e que o silicone experimental precisa ser estudado com vistas em sua aplicabilidade clínica. / This study evaluated the color change, Shore A hardness, tear resistance and elastic recovery of an experimental silicone (Ortho Pauher - O), compared to a silicone used in facial rehabilitation (MDX 4-4210 - MDX), when submitted to pigmentation and accelerated aging and also examined the microstructure of these materials. To analyze the color change and hardness, we were obtained 160 circular specimens (80/material); for the elastic recovery, 200 cylindrical specimens were obtained (100/material) and for the tear strength, 200 specimens were fabricated in the form of pants (100/material). Half of the samples received intrinsic pigmentation and the other half received intrinsic and extrinsic pigmentation, also by applying makeup powder. Subsequently, the specimens were randomly distributed into three groups of aging: 1 - thermocycling (T), 2 - ultraviolet light (UV) and 3 - natural light (NL). All of the aging steps simulated a period of 1-year. As a control (C), the specimens were kept in a closed container in total absence of light for 1-year. For the micro structural analysis, three specimens of each group were subjected to Scanning Electron Microscopy (SEM), Infrared Spectroscopy (EI), Differential Scanning Calorimetry (DSC) and Thermogravimetry (TG). For statistical analysis tests were used ANOVA and Tukeys test (p<0.05). For the micro structural analysis, the results were presented in tables and graphs. For color change, there was no difference between the materials and pigmentation. The UV, LN and T aging, promoted the greatest change. MDX was altered in function of the IEP, T and UV and Ortho Pauher, according to the PI/UV and IEP/T and UV. For hardness, Ortho Pauher silicone and IP showed the greatest changes, as well as the LN and UV. Both materials varied depending on the pigmentation and aging. For tear strength, difference was found for all factors and interaction. The Silicone Ortho Pauher and IP promoted the lowest averages. The MDX was altered depending of the pigmentation and aging. In the elastic recovery, the material M and the PIE group showed the highest average. For aging, UV resulted in lower recovery and higher values were found in the C and LN. The two materials were changed according to pigmentation and aging. The micro structural analyzes showed that the polymerization was completed and the material and the pigments added, in the proportions used, do not influence the stability of the materials. The study results suggest that the changes found in physical-mechanical properties, depending on exposure to different pigmentation and aging, do not represent important structural alterations and the experimental silicone needs to be studied with a view to its clinical applicability.
29

Prótese óculopalpebral com captação de movimento palpebral: proposta de dispositivo mecânico / Oculopalpebral prosthesis with eyelid motion capture: mechanical appliance proposition

Vieira, Lívia Morelli 08 April 2016 (has links)
Introdução: A reconstrução de grandes defeitos da face nem sempre é passível de correção cirúrgica, podendo ser restaurados com as próteses faciais. Apesar da prótese óculopalpebral apresentar uma aparência natural, ela é facilmente notada, pois não apresenta os movimentos palpebrais de abertura e fechamento sincronizadas com o olho contralateral, tornando assim a reconstrução protética um grande desafio. Objetivos: Planejar, desenhar, viabilizar e construir um protótipo com recurso mecânico/elétrico possibilitando sincronia dos movimentos palpebrais com o olho sadio para utilização em prótese óculopalpebral. Material e Métodos: Confecção de uma prótese óculopalpebral com um dispositivo de pálpebra móvel em silicone médico capaz de conectar-se a um sistema mecânico-elétrico responsável por realizar movimentos de abertura e fechamento da pálpebra móvel da prótese. Resultados e Discussão: Foi confeccionada uma prótese óculo-palpebral em resina acrílica termicamente ativada, criando-se um nicho para a acomodação de um sistema elétrico e possibilitar a livre movimentação de uma fina pálpebra em silicone interligada ao dispositivo tornando possível a conexão desse sistema com um sensor que capta o movimento palpebral de um olho saudável. Conclusão: No presente estudo um protótipo mecânico - elétrico foi planejado, desenhado e desenvolvido acoplado a uma prótese óculopalpebral estabelecendo e sincronizando seus movimentos palpebrais com o olho sadio. / Introduction: Surgical reconstruction of large facial defects may not be always possible. Extraoral maxillofacial prosthesis are a good restorative option. Even though when the oculopalpebral prosthesis presents a natural appearance, it can be easily noticed because its eyelids do not move. It is desirable for the eyelids to open and close synchronously with contralateral eye. Thus, prosthetic reconstruction of oculopalpebral region is a great challenge. Objectives: To plan, design, enable and build a oculopalpebral prosthesis prototype with mechanical and electric features allowing eyelid motion with synchronization with the sound eye. Material and method: Fabrication of an oculopalpebral prosthesis with a medical grade silicone movable eyelid which has the capability to connect itself to an mechanical-eletrical system responsible to make opening and closing movements on prosthesis movable eyelid. Results and discussion: An oculopalpebral prosthesis was made in thermoactivated acrylic resin. A gap was created to accomodate an electrical system and also allow free motion of a thin silicone eyelid attached to the dispositive. This system can be connected to a sensor which captured the eyelid motion of a sound eye. Conclusion: A mechanical-electrical prototype was planned, designed and developed attached to an oculopalpebral prosthesis stablishing and synchronizing its eyelid movements with the sound eye.
30

Avaliação de fala de pacientes submetidos à glossectomia após adaptação de prótese rebaixadora de palato / Speech evaluation after palatal augmentation in glossectomy patients

Silva, Viviane de Carvalho Teles da 05 April 2007 (has links)
O objetivo principal deste estudo foi avaliar a influência da adaptação da prótese rebaixadora de palato na inteligibilidade e na ressonância de fala, e nas características acústicas espectrográficas dos três primeiros formantes das vogais orais do português brasileiro de pacientes submetidos à glossectomia. Participaram 36 pacientes, 33 do sexo masculino e 3 do sexo feminino, com idades entre 30 e 80 anos (Média=53,91±10,53 anos), sendo 14 submetidos à glossectomia total, 12 à glossectomia total e mandibulectomia parcial, 6 à hemiglossectomia e, 4 à glossectomia subtotal. Amostras de fala (conversa espontânea e repetição de 18 sílabas) de pacientes com e sem prótese foram randomizadas e a ressonância e inteligibilidade de fala foram julgadas por 2 fonoaudiólogos. Também foi realizada a análise espectrográfica dos formantes das 7 vogais do português brasileiro com e sem prótese, extraindo-se as médias dos três primeiros formantes. Houve melhora significante na inteligibilidade de fala e de sílabas após adaptação da prótese rebaixadora de palato (p < 0,001). Não houve diferença estatística nos julgamentos da ressonância com e sem prótese. Existiu diferença significante na situação com e sem prótese para o primeiro formante nas vogais /a/, /e/, /u/ (p < 0,001) e tendência estatística na vogal /o/ (p = 0,09); para segundo formante nas vogais /o/, / /, /u/ (p < 0,001), e tendência estatística nas vogais /e/ (p = 0,058) e /i/ (p = 0,080) e para o terceiro formante nas vogais /a/ e / / (p < 0,001). A prótese rebaixadora de palato melhorou a inteligibilidade da fala espontânea e das sílabas dos pacientes glossectomizados. Também aumentou os valores de F2 e F3 para todas as vogais e, de F1 para as vogais /o/, / /, /u/. Isto gerou uma aproximação dos valores dos formantes da maioria das vogais junto aos valores de normalidade. / The main objective of this study was to assess the influence of the palatal augmentation prostheses on speech intelligibility, ressonance and acoustic spectrographic characteristics of the first three formants of oral vowels in Brazilian Portuguese, in patients submitted to glossectomy. Thirty-six (33 men and 3 women), aged 30 to 80 years (mean = 53.9 ±10.5 years) underwent glossectomy (14 = total glossectomy; 12 = total glossectomy associated partial mandibulectomy; 6=hemiglossectomy, and 4 = subtotal glossectomy) constituted the study sample. Speech samples (spontaneous conversation and repetition of 18 syllables) from the patients with and without prosthesis were randomly distributed and the resonance and speech intelligibility were judged by 2 speech language pathologist. A spectrographic assessment of formants of the 7 vowels of Brazilian Portuguese, with and without prosthesis, was performed. The mean values of the first three formants were extracted. There was a statistically significant improvement of the spontaneous speech intelligibility and of the average number of correctly identified syllables with the use of the prosthesis (p<0.05). The speech resonance results have not demonstrated a significant reduction in hypernasality with the palatal augmentation prostheses in place. Statistically significant differences occurred in F1 values for the vowels /a/, /e/, /u/, for F2, there was a significant difference in the vowels /o/, / /, /u/; and for F3, there was a significant difference in the vowels /a/, / / (p < 0.001). Palatal augmentation prosthesis improved intelligibility of spontaneous speech and syllables in glossectomized patients. It also increased F2 and F3 values for all vowels and F1 values for the vowels /o/, / /, /u/. This effect has brought the values of many vowel formants closer to normality.