• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 45
  • 10
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • Tagged with
  • 59
  • 59
  • 39
  • 38
  • 16
  • 15
  • 15
  • 13
  • 13
  • 12
  • 12
  • 10
  • 10
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado

Nobrega, Adhara Smith [UNESP] 20 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-20Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000795003.pdf: 1118199 bytes, checksum: 98a54dea093e378451b9a2f7d2e032e2 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / FAPESP: 12/05270-3
42

Influência da adição de nanopartículas sobre a dureza, resistência à ruptura e deformação permanente de silicone facial submetido ao envelhecimento acelerado /

Nobrega, Adhara Smith. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Mário Alexandre Coelho Sinhoreti / Resumo: Apesar de satisfatórias, as próteses maxilofaciais apresentam limitações quanto à estética, conforto e durabilidade. Por isso estudos com o objetivo de melhorar as propriedades desses materiais são incessantes. É comprovada a eficiência da adição de nanopartículas na proteção de silicones, evitando a degradação da sua cor, no entanto a literatura é escassa quando se refere a outras alterações das propriedades físicas causadas no silicone facial. Assim, o objetivo deste estudo é avaliar a influência da adição de nanopartículas na ruptura, deformação permanente e dureza do Silicone Facial Silastic MDX4-4210. Foram confeccionadas 560 amostras em silicone facial, sendo 280 dessas amostras para o teste de ruptura, 140 para o teste de dureza e 140 para o teste de deformação permanente. As nanopartículas adicionadas na confecção das amostras de silicone foram: óxido de zinco (ZnO); sulfato de bário (BaSO4) e dióxido de titânio (TiO2). Para cada teste (exceção do teste de ruptura, no qual a quantidade de amostras será confeccionada em duplicata), 40 amostras de silicone serão confeccionadas com adição de cada um dos tipos de nanopartículas, totalizando 120 amostras; 10 amostras de silicone com tinta a óleo, sem nanopartículas, e 10 amostras somente de silicone .Para cada tipo de nanopartícula adicionada ao silicone facial, 20 amostras foram confeccionadas na concentração de 1% e 20 na concentração de 2%. Para cada concentração de nanopartículas, metade (10 amostras) foi com adição de tinta a óleo e a outra metade sem tinta a óleo. As amostras foram submetidas aos ensaios de dureza, resistência à ruptura e deformação permanente, e 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Pode-se... / Abstract: Although satisfactory, the maxillofacial prostheses present aesthetics, comfort and durability limitations. Therefore, studies with the purpose to obtain better properties of these materials are unceasing. The efficiency of adding nanoparticles to silicon protection is well proven in preventing its color degradation, however the literature is scarce when it comes to other physical property changes with infacial silicon.The aim of this study is to evaluate the influence of nanoparticles addition to hardness, rupture resistance and permanent deformation of Facial Silicone Silastic MDX4-4210. 560 samples of facial silicone were made, 280 for rupture resistance test, 140 for hardness test and 140 for permanent deformation test. Nanoparticles added in the preparation of silicone samples were zinc oxide (ZnO), barium sulfate (BaSO4) and titanium dioxide (TiO2). For each test (except the rupture test, in which the samples are duplicated), 40 samples will be made of silicon added to each type of nanoparticles, totaling 120 samples, 10 samples of silicone with oil paint without nanoparticles, and 10 samples only of silicone (control group). For each type of nanoparticle added to the facial silicone, 20 samples were prepared at a concentration of 1% and 20 at a concentration of 2%. For every concentration of nanoparticles, half (10 samples) were added oil paint and the other half without oil paint. Samples were submitted to testing hardness, rupture resistance and permanent deformation, and 1008 hours of accelerated aging. The data were subjected to statistical analysis using nested ANOVA and Tukey tests. It can be verified through the results that the presence of nanoparticles influenced the hardness, tear strength and permanent deformation of the assessed groups. We conclude that all evaluated nanoparticles influenced the hardness, tear strength and permanent... / Mestre
43

Influência de pigmentos e opacificadores na estabilidade de cor, dureza, absorção e solubilidade de um silicone facial submetido ao envelhecimento acelerado /

Santos, Daniela Micheline dos. January 2009 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Stefan Fiúza de Carvalho Dekon / Banca: Ricardo Coelho Okida / Banca: Aimeé Maria Guiotti / Banca: Fellippo Ramos Verri / Resumo: O presente estudo teve por objetivo avaliar a influência de dois pigmentos (pó de cerâmica e tinta a óleo) e um opacificador (sulfato de barium) sobre as propriedades físicas de estabilidade de cor, dureza, absorção e solubilidade do silicone facial MDX4-4210, submetido ao envelhecimento acelerado. Para a confecção das amostras, foram utilizadas 2 matrizes metálicas em alumínio, contendo em seu interior 10 compartimentos circulares com 45mm de diâmetro apresentando estes, em uma matriz, uma espessura de 2mm para os testes de estabilidade de cor e dureza e, na outra, 1mm para os ensaios de absorção e solubilidade. Foram confeccionadas 120 amostras, metade para os ensaios de análise cromática e dureza e, a outra metade, para o teste de absorção e solubilidade. As amostras destinadas para cada teste foram distribuídas em seis grupos, incolor (G1), incolor com opacificador (G2), cerâmica (G3), cerâmica com opacificador (G4), óleo (G5), óleo com opacificador (G6). Após a obtenção das amostras, a análise cromática inicial foi verificada por meio da análise visual e da espectrofotometria de reflexão. Os ensaios de dureza foram realizados com auxílio de um durômetro Shore A. Os testes de absorção e solubilidade foram realizados por meio de um dessecador no qual as amostras permaneceram neste ambiente em estufa à temperatura de 37±2°C, sendo pesadas diariamente até obtenção de massa constante (W1); posteriormente as amostras foram submetidas ao envelhecimento seguido de nova pesagem (W2), e nova dessecação com pesagem final (W3). As amostras foram submetidas ao envelhecimento acelerado por 1008 horas, sendo os ensaios realizados nos períodos correspondentes a 252, 504 e 1008 horas. Os dados obtidos foram submetidos à ANOVA e Tukey, com significância de 5%. Pode-se observar pela análise espectrofotométrica que os grupos com opacificador apresentaram melhor... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to evaluate the influence of two pigments (ceramic powder and oil paint) and one opacifier (barium sulfate) on physical properties of color stability, hardness, absorption and solubility of the facial silicone MDX4-4210 submitted to artificial aging. The replicas were fabricated in two metallic matrixes in aluminum containing 10 circular compartments with 45mm in diameter. One matrix generated specimens with 2mm in thickness for color stability and hardness evaluations while the other matrix, specimens with 1mm in thickness for absorption and solubility tests. The replicas were divided into six groups: colorless (G1), colorless with opacifier (G2), ceramic (G3), ceramic with opacifier (G4), oil (G5) and oil with opacifier (G6). Initial chromatic evaluation was performed by visual analysis and reflection spectrophotometry. The hardness tests were carried out by a Shore A durometer. The evaluations of absorption and solubility were performed through a desiccator to maintain the replicas in a stove at 37±2°C. The specimens were weighed daily until obtaining a constant mass, (W1). Then, the replicas were submitted to aging followed by a new weighing (W2) and drying with final weighing (W3). The replicas were submitted to accelerated aging during 1008 hours with evaluation after 252, 504 and 1008 hours. Data were submitted to statistical analysis by ANOVA and Tukey's test at 5% level of significance. According to spectrophotometry, the groups with opacifier presented statistically significant better chromatic stability than the other groups. The accelerated aging generated significant chromatic alterations in all groups, except for colorless and oil groups both with opacifier. There was no statistically significant difference among the groups after aging regarding hardness, absorption and solubility. According to the results, it may be concluded that... (Complete abstract, click electronic access below) / Doutor
44

Avaliação das propriedades físicas de dois materiais flexíveis de produção nacional para uso em prótese facial / Evaluation of the physical properties of two flexível materials domestic produced, to create facial prosthesis

Luis Pablo Herrera Tinajero 19 January 2011 (has links)
Para confeccionar próteses faciais e reabilitar aqueles pacientes com perdas anatômicas, são empregados diversos materiais, destacando-se entre estes os flexíveis,devido á semelhança estética que apresentam com a pele humana. O padrão de qualidade dos materiais é liderado por produtos estrangeiros, tornando difícil a obtenção e, por tanto, a aplicação dos mesmos em território nacional. Devido à necessidade de se ter materiais nacionais com qualidade semelhante aos importados, este trabalho mensurou dois materiais, a resina resiliente CLASSIFLEX e o silicone médico ORTHO PAUER, ambos de produção nacional, seguindo as normas da ASTM (American Standard for testing materiais). Foram testadas dureza Shore A, resistência ao rasgamento, resistência a tração e alongamento de ruptura. Os valores obtidos foram analisados estatisticamente e comparados entre sim. Os valores de resistência a tração, resistência ao rasgamento e dureza Shore A, dos materiais testados foram baixos quando comparados com os valores encontrados em outras pesquisas .Os valores de Alongamento de ruptura se encontram dentro dos valores aceitáveis para matérias de uso em reabilitação buco maxilo facial. / To fabricate and create facial prosthesis for those patients with anatomical loss, maxillo facial protesiologist use differet materials. Flexible materials has being used mostly because of their aesthetic similarity with the skin. The standard for quality in prostethic materilas is led by foreign products, making it difficult to obtain and apply these materials in national territory. Due to the necessity of giving new and better materilas the CLASSIFLEX resilient resin and the ORTHO PAUER medical silicone, both of domestic production, were selected to test the fisical properties of: Shore A hardness, elongation, tensile strength and tear strenght. The specimens were made following the parameters indicated by the ASTM and each test was performed. The values obtained were analyzed statistically and compared. The results obtained may conclude that the physical properties of tensile srtrenght, tear strenght and Shore A hardness were low when compared with the results observed in other similar studies. The values obtained from the elongation test shows similarity of other values obtained by past studies.
45

Prótese óculopalpebral com captação de movimento palpebral: proposta de dispositivo mecânico / Oculopalpebral prosthesis with eyelid motion capture: mechanical appliance proposition

Lívia Morelli Vieira 08 April 2016 (has links)
Introdução: A reconstrução de grandes defeitos da face nem sempre é passível de correção cirúrgica, podendo ser restaurados com as próteses faciais. Apesar da prótese óculopalpebral apresentar uma aparência natural, ela é facilmente notada, pois não apresenta os movimentos palpebrais de abertura e fechamento sincronizadas com o olho contralateral, tornando assim a reconstrução protética um grande desafio. Objetivos: Planejar, desenhar, viabilizar e construir um protótipo com recurso mecânico/elétrico possibilitando sincronia dos movimentos palpebrais com o olho sadio para utilização em prótese óculopalpebral. Material e Métodos: Confecção de uma prótese óculopalpebral com um dispositivo de pálpebra móvel em silicone médico capaz de conectar-se a um sistema mecânico-elétrico responsável por realizar movimentos de abertura e fechamento da pálpebra móvel da prótese. Resultados e Discussão: Foi confeccionada uma prótese óculo-palpebral em resina acrílica termicamente ativada, criando-se um nicho para a acomodação de um sistema elétrico e possibilitar a livre movimentação de uma fina pálpebra em silicone interligada ao dispositivo tornando possível a conexão desse sistema com um sensor que capta o movimento palpebral de um olho saudável. Conclusão: No presente estudo um protótipo mecânico - elétrico foi planejado, desenhado e desenvolvido acoplado a uma prótese óculopalpebral estabelecendo e sincronizando seus movimentos palpebrais com o olho sadio. / Introduction: Surgical reconstruction of large facial defects may not be always possible. Extraoral maxillofacial prosthesis are a good restorative option. Even though when the oculopalpebral prosthesis presents a natural appearance, it can be easily noticed because its eyelids do not move. It is desirable for the eyelids to open and close synchronously with contralateral eye. Thus, prosthetic reconstruction of oculopalpebral region is a great challenge. Objectives: To plan, design, enable and build a oculopalpebral prosthesis prototype with mechanical and electric features allowing eyelid motion with synchronization with the sound eye. Material and method: Fabrication of an oculopalpebral prosthesis with a medical grade silicone movable eyelid which has the capability to connect itself to an mechanical-eletrical system responsible to make opening and closing movements on prosthesis movable eyelid. Results and discussion: An oculopalpebral prosthesis was made in thermoactivated acrylic resin. A gap was created to accomodate an electrical system and also allow free motion of a thin silicone eyelid attached to the dispositive. This system can be connected to a sensor which captured the eyelid motion of a sound eye. Conclusion: A mechanical-electrical prototype was planned, designed and developed attached to an oculopalpebral prosthesis stablishing and synchronizing its eyelid movements with the sound eye.
46

Evolução dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial: revisão sistemática / Evolution of retention, fixation and anchorage extraoral in maxillofacial rehabilitation systems: a systematic review

Marcus Vinicius Cobein 02 July 2014 (has links)
Introdução: A utilização de próteses bucomaxilofaciais é de extrema importância para a reintegração no convívio social dos pacientes acometidos de deformidades congênitas ou adquiridas. Tendo em vista os avanços dos sistemas de retenção, fixação e ancoragem extraoral na reabilitação bucomaxilofacial realizou-se revisão sistemática. Objetivos: verificar a evolução das retenções das próteses bucomaxilofaciais comparando os sistemas osseointegrados, aos sistemas não osseointegrados, analisando algumas variáveis como: taxa de sobrevivência dos implantes ao longo do tempo, idade média dos pacientes, etiologia do defeito facial e sitio dos sistemas de retenção relacionado ao tipo de prótese, em formato de revisão sistemática. Métodos: Realizou-se busca bibliográfica nas bases de dados PubMed e SCOPUS, após elaboração de estratégias de busca, obteve-se 2630 artigos onde foram analisados títulos, resumos e eliminadas duplicidades. Resultados: Obteve-se 25 artigos pré-selecionados que passaram pelos critérios de inclusão e exclusão sendo eleitos 13 artigos para a revisão sistemática. Conclusão: As próteses retidas por implantes superam os sistemas convencionais. A perda dos implantes foi muito pequena nos estudos analisados, apesar do tempo de acompanhamento ser relativamente curto e dos protocolos distintos de tratamento. A idade adulta entre a quarta e quinta década de vida foi a de maior prevalência. A etiologia mais incidente são as neoplasias. Os sistemas osseointegrados fixados por implantes por retenção barra clipe se localizam mais na região auricular e retenção magnética nas regiões nasal e orbital. Os sistemas não osseointegrados, a retenção anatômica é mais utilizada na região ocular, retenção mecânica na região orbital e o uso da retenção por adesivos nas regiões nasal e orbital. / Introduction: The use of maxillofacial prostheses is the most importance for reintegration into social life of patients suffering from congenital or acquired deformities. Given the advances in retention, fixation and extraoral anchorage systems in maxillofacial rehabilitation got systematic review. Objectives: To observe the evolution of the retentions of maxillofacial prostheses comparing osseointegrated systems, non osseointegrated systems, analyzing some variables such as survival rate of implants over time, mean patient age, etiology of facial defect and place restraint systems related kind of prosthesis, in a systematic review format. Methods: We performed a literature search in PubMed and SCOPUS database, after preparation of search strategies, we obtained 2630 articles where were checking titles, abstracts and eliminated duplicates were analyzed. Results: We obtained 25 pre-selected articles that passed the criteria for inclusion and exclusion being elected 13 articles for systematic review. Conclusion: The dentures retained by implants outperform conventional systems. The loss of the implants was very small in the analyzed studies, although the follow-up time is relatively short and the different treatment protocols. Between the fourth and fifth ages of life was the most prevalent. The most frequent etiology are neoplasms. Osseointegrated systems for fixed for implants retention bar clip are located more auricular and magnetic retention in the regions nasal and orbital. Non osseointegrated systems, anatomical retention is most commonly used in the ocular region, mechanical retention in orbital region and the use of adhesives for retention in the regions nasal and orbital.
47

Avaliação de fala de pacientes submetidos à glossectomia após adaptação de prótese rebaixadora de palato / Speech evaluation after palatal augmentation in glossectomy patients

Viviane de Carvalho Teles da Silva 05 April 2007 (has links)
O objetivo principal deste estudo foi avaliar a influência da adaptação da prótese rebaixadora de palato na inteligibilidade e na ressonância de fala, e nas características acústicas espectrográficas dos três primeiros formantes das vogais orais do português brasileiro de pacientes submetidos à glossectomia. Participaram 36 pacientes, 33 do sexo masculino e 3 do sexo feminino, com idades entre 30 e 80 anos (Média=53,91±10,53 anos), sendo 14 submetidos à glossectomia total, 12 à glossectomia total e mandibulectomia parcial, 6 à hemiglossectomia e, 4 à glossectomia subtotal. Amostras de fala (conversa espontânea e repetição de 18 sílabas) de pacientes com e sem prótese foram randomizadas e a ressonância e inteligibilidade de fala foram julgadas por 2 fonoaudiólogos. Também foi realizada a análise espectrográfica dos formantes das 7 vogais do português brasileiro com e sem prótese, extraindo-se as médias dos três primeiros formantes. Houve melhora significante na inteligibilidade de fala e de sílabas após adaptação da prótese rebaixadora de palato (p < 0,001). Não houve diferença estatística nos julgamentos da ressonância com e sem prótese. Existiu diferença significante na situação com e sem prótese para o primeiro formante nas vogais /a/, /e/, /u/ (p < 0,001) e tendência estatística na vogal /o/ (p = 0,09); para segundo formante nas vogais /o/, / /, /u/ (p < 0,001), e tendência estatística nas vogais /e/ (p = 0,058) e /i/ (p = 0,080) e para o terceiro formante nas vogais /a/ e / / (p < 0,001). A prótese rebaixadora de palato melhorou a inteligibilidade da fala espontânea e das sílabas dos pacientes glossectomizados. Também aumentou os valores de F2 e F3 para todas as vogais e, de F1 para as vogais /o/, / /, /u/. Isto gerou uma aproximação dos valores dos formantes da maioria das vogais junto aos valores de normalidade. / The main objective of this study was to assess the influence of the palatal augmentation prostheses on speech intelligibility, ressonance and acoustic spectrographic characteristics of the first three formants of oral vowels in Brazilian Portuguese, in patients submitted to glossectomy. Thirty-six (33 men and 3 women), aged 30 to 80 years (mean = 53.9 ±10.5 years) underwent glossectomy (14 = total glossectomy; 12 = total glossectomy associated partial mandibulectomy; 6=hemiglossectomy, and 4 = subtotal glossectomy) constituted the study sample. Speech samples (spontaneous conversation and repetition of 18 syllables) from the patients with and without prosthesis were randomly distributed and the resonance and speech intelligibility were judged by 2 speech language pathologist. A spectrographic assessment of formants of the 7 vowels of Brazilian Portuguese, with and without prosthesis, was performed. The mean values of the first three formants were extracted. There was a statistically significant improvement of the spontaneous speech intelligibility and of the average number of correctly identified syllables with the use of the prosthesis (p<0.05). The speech resonance results have not demonstrated a significant reduction in hypernasality with the palatal augmentation prostheses in place. Statistically significant differences occurred in F1 values for the vowels /a/, /e/, /u/, for F2, there was a significant difference in the vowels /o/, / /, /u/; and for F3, there was a significant difference in the vowels /a/, / / (p < 0.001). Palatal augmentation prosthesis improved intelligibility of spontaneous speech and syllables in glossectomized patients. It also increased F2 and F3 values for all vowels and F1 values for the vowels /o/, / /, /u/. This effect has brought the values of many vowel formants closer to normality.
48

Nano ceramic fiber reinforced silicone maxillofacial prosthesis

Al-Qenaei, Nouri, 1975- January 2010 (has links)
Indiana University-Purdue University Indianapolis (IUPUI) / The purpose of this study was to investigate the effect of nano ceramic fiber fillers on the physical properties of VST-50HD silicone maxillofacial prosthesis. Nano alumina fibers at 2 percent, 4-percent, and 6-percent wt were mixed into the VST-50HD silicone elastomer (Factor II Inc., Lakeside, AZ), a commercially-available poly(dimethylsiloxanes). Ten dumb-bell-shaped specimens were used to determine the tensile strength according to ISO 37:2005 and elongation at fracture. Ten trouser-shaped test pieces were used to determine the tear resistance according to ISO 34-1:2004. Shore A test method was used to measure the hardness of the material. The data collected from all quantitative studies of the modified silicones were analyzed using one-way ANOVA with concentration of nano ceramic fiber as the main variable. Specimens from VST- 50HD were also made and tested as control. Results: The mean values for tensile strength (MPa) of control group, 2-percent, 4-percent, and 6-percent reinforced nano ceramic fiber fillers were from 3.43 ± 0.12 to 5.48 ± 0.71. Tear strength (MPa) were from 2.34 ± 0.37 to 5.01 ± 0.39. Elongations at fracture were from 699.66 ± 43.69 to 793.51 ± 57.27. Shore A hardness were from 25.76 ± 2.18 to 38.76 ± 1.83. Conclusion: There was a significant difference (p < 0.001) in the mean tensile, tear and Shore A hardness strengths between the control group and 2-percent, 4-percent, and 6-percent percent reinforced nano ceramic fiber fillers; however, there was not a significant difference (p > 0.05) between 2-percent, 4-percent, and 6-percent reinforced nano ceramic fiber fillers. There was a significant difference (p < 0.001) in the mean elongation at fracture between the 2-percent and control group, 4-percent, and 6-percent reinforced nano ceramic fiber fillers; however, there was not a significant difference (p > 0.05) between control group, 4-percent, and 6-percent reinforced nano ceramic fiber fillers. The properties of the experiment were all lower than the control. Further research is needed to determine the appropriate material and amount of dispersing agent, coupling agent, and determination of the hydprophilicity of the nano ceramic fiber fillers with great emphasis on the dispersing agent.
49

Avaliação da influência da pigmentação, opacificador e envelhecimento nas propriedades físicas e mecânicas de um silicone experimental para prótese bucomaxilofacial / Evaluation of the influence of pigmentation, opacifier and aging on physical and mechanical properties of an experimental silicone for maxillofacial prosthesis

Vomero, Marina Peris 29 January 2015 (has links)
O objetivo deste estudo foi propor a utilização de um novo silicone (Bio-Skin - BS) para prótese bucomaxilofacial. Foram analisadas alteração de cor, dureza Shore A, resistência à tração, características de superfície (MEV) e composição química (EDS) frente à diferentes pigmentações e envelhecimentos. Como parâmetro de comparação foi empregado o silicone MDX4-4210. Foram obtidos 120 espécimes para cada material com formato circular e 160 em forma de haltere, a partir de matrizes metálicas de corte, os quais foram distribuídos em 4 grupos: PI - pigmentação intrínseca (pó de maquiagem); OP - opacificador (sulfato de bário, BaSO4); PIO - associação de PI + OP; SP - sem adição de PI ou OP. Em seguida, os espécimes foram distribuídos aleatoriamente em 3 subgrupos para exposição ao envelhecimento por luz natural (LN, n=10), luz ultravioleta (UV, n=10) e ausência de luz (C, n=10). O período experimental foi de 12 meses. A alteração de cor foi verificada com auxílio de espectrocolorímetro e sistema CIE L*a*b*. Para a dureza foi utilizado um durômetro Shore A e a análise da resistência à tração foi realizada em máquina universal de ensaio. As variáveis de resposta quantitativas foram mensuradas imediatamente após a obtenção dos espécimes e após o período experimental. A análise de superfície foi realizada por microscopia eletrônica de varredura (MEV) e a composição química dos silicones, por espectroscopia por energia dispersiva (EDS). Os dados foram submetidos à análise de variância e teste complementar de Tukey (p<0,05). Os resultados das análises por MEV e EDS foram apresentados em imagens e gráficos. Houve interação entre todos os fatores (p<0,05) e ambos os materiais sofreram variações em função das pigmentações e envelhecimentos. Para alteração de cor, o silicone experimental (BS) apresentou as menores variações de cor. Analisando os silicones em função da pigmentação, o MDX apresentou maiores variações com os espécimes SP e com OP envelhecidos por luz natural e luz UV. Para o BS, houve alteração significativa da cor dos espécimes SP e OP somente após o envelhecimento por LN. Os dois materiais apresentaram aumento da dureza frente a todas as condições, sendo que o silicone BS apresentou a maior variação. O silicone experimental apresentou resistência à tração superior ao MDX em todas as situações. O MDX não sofreu influência significativa na resistência à tração por nenhuma das pigmentações ou envelhecimento, exceto quanto pigmentado com pó de maquiagem e envelhecido por UV, onde houve aumento da resistência. Quanto ao silicone BS, os maiores valores de resistência à tração foram encontrados com a PI e PIO em todos os grupos de envelhecimento. Pode-se considerar que o material experimental apresentou resultados favoráveis em relação à alteração de cor, dureza Shore A e resistência à tração para sua aplicação clínica em prótese bucomaxilofacial. A associação da pigmentação intrínseca, por meio de pó de maquiagem com opacificador, protegeu o silicone da alteração de cor e promoveu alterações aceitáveis nas propriedades mecânicas dos materiais. Todos os processos de envelhecimento promoveram alterações nas propriedades dos materiais. / The aim of this study was to propose the use of a new silicone (Bio-Skin - BS) for maxillofacial prosthesis. Color change, Shore A hardness, tensile strength, surface characteristics (SEM) and chemical composition (EDS) were analyzed, regarding different pigmentation and aging methods. The MDX4-4210 silicone was used as parameter of comparison. Specimens (120 circular and 160 dumbbell-shaped) were obtained for each material, from metal cutting molds, which were divided into 4 groups: IP - intrinsic pigmentation (makeup powder); OP - opacifier (barium sulfate, BaSO4); IPO - IP + OP association; WP - without adding IP or OP. Then, the specimens were randomly divided into 3 subgroups to aging by exposure to natural light (NL, n = 10), ultraviolet light (UV, n = 10) and without light (C, n = 10). The experimental period was 12 months. The color change was observed with spectrocolorimeter and CIE L*a*b* system. For hardness we used a Shore A durometer and the analysis of tensile strength was performed in a universal testing machine. The quantitative response variables were measured immediately after obtaining the specimens and after the experimental period. The surface analysis was performed by scanning electron microscopy (SEM) and the chemical composition of silicones, by energy dispersive spectroscopy (EDS). Data were submitted to ANOVA and Tukey\'s test (p <0.05). SEM and EDS results were presented in pictures and graphics. There was interaction between all factors (p <0.05) and both materials varied depending on the pigmentation and aging methods. For color change, the experimental silicone (BS) showed the lowest color variations. Analyzing the silicones due to the pigmentation, the MDX showed higher variation with the WP and OP specimens aged in natural light and UV light. For BS, there was significant change in the color of the WP and OP specimens only after aging for NL. The two materials presented an increase in hardness front of all conditions, and the BS silicone showed the greatest variation. The experimental silicone showed superior tensile strength to MDX in all situations. The MDX was not affected in tensile strength by any pigmentation or aging, except for the group pigmented with makeup powder and aged by UV, where there was an increase of resistance. As to BS silicone, the highest tensile strength values were found for the IP and IPO in all age groups. It can be considered that the experimental material showed favorable results regarding color change, Shore A hardness and tensile strength for clinical use in maxillofacial prosthesis. The association of intrinsic pigmentation through makeup powder and opacifier, protected silicone of color change and promoted acceptable changes in mechanical properties of the materials. All the aging processes promoted changes in material properties.
50

Avaliação da influência da pigmentação, opacificador e envelhecimento nas propriedades físicas e mecânicas de um silicone experimental para prótese bucomaxilofacial / Evaluation of the influence of pigmentation, opacifier and aging on physical and mechanical properties of an experimental silicone for maxillofacial prosthesis

Marina Peris Vomero 29 January 2015 (has links)
O objetivo deste estudo foi propor a utilização de um novo silicone (Bio-Skin - BS) para prótese bucomaxilofacial. Foram analisadas alteração de cor, dureza Shore A, resistência à tração, características de superfície (MEV) e composição química (EDS) frente à diferentes pigmentações e envelhecimentos. Como parâmetro de comparação foi empregado o silicone MDX4-4210. Foram obtidos 120 espécimes para cada material com formato circular e 160 em forma de haltere, a partir de matrizes metálicas de corte, os quais foram distribuídos em 4 grupos: PI - pigmentação intrínseca (pó de maquiagem); OP - opacificador (sulfato de bário, BaSO4); PIO - associação de PI + OP; SP - sem adição de PI ou OP. Em seguida, os espécimes foram distribuídos aleatoriamente em 3 subgrupos para exposição ao envelhecimento por luz natural (LN, n=10), luz ultravioleta (UV, n=10) e ausência de luz (C, n=10). O período experimental foi de 12 meses. A alteração de cor foi verificada com auxílio de espectrocolorímetro e sistema CIE L*a*b*. Para a dureza foi utilizado um durômetro Shore A e a análise da resistência à tração foi realizada em máquina universal de ensaio. As variáveis de resposta quantitativas foram mensuradas imediatamente após a obtenção dos espécimes e após o período experimental. A análise de superfície foi realizada por microscopia eletrônica de varredura (MEV) e a composição química dos silicones, por espectroscopia por energia dispersiva (EDS). Os dados foram submetidos à análise de variância e teste complementar de Tukey (p<0,05). Os resultados das análises por MEV e EDS foram apresentados em imagens e gráficos. Houve interação entre todos os fatores (p<0,05) e ambos os materiais sofreram variações em função das pigmentações e envelhecimentos. Para alteração de cor, o silicone experimental (BS) apresentou as menores variações de cor. Analisando os silicones em função da pigmentação, o MDX apresentou maiores variações com os espécimes SP e com OP envelhecidos por luz natural e luz UV. Para o BS, houve alteração significativa da cor dos espécimes SP e OP somente após o envelhecimento por LN. Os dois materiais apresentaram aumento da dureza frente a todas as condições, sendo que o silicone BS apresentou a maior variação. O silicone experimental apresentou resistência à tração superior ao MDX em todas as situações. O MDX não sofreu influência significativa na resistência à tração por nenhuma das pigmentações ou envelhecimento, exceto quanto pigmentado com pó de maquiagem e envelhecido por UV, onde houve aumento da resistência. Quanto ao silicone BS, os maiores valores de resistência à tração foram encontrados com a PI e PIO em todos os grupos de envelhecimento. Pode-se considerar que o material experimental apresentou resultados favoráveis em relação à alteração de cor, dureza Shore A e resistência à tração para sua aplicação clínica em prótese bucomaxilofacial. A associação da pigmentação intrínseca, por meio de pó de maquiagem com opacificador, protegeu o silicone da alteração de cor e promoveu alterações aceitáveis nas propriedades mecânicas dos materiais. Todos os processos de envelhecimento promoveram alterações nas propriedades dos materiais. / The aim of this study was to propose the use of a new silicone (Bio-Skin - BS) for maxillofacial prosthesis. Color change, Shore A hardness, tensile strength, surface characteristics (SEM) and chemical composition (EDS) were analyzed, regarding different pigmentation and aging methods. The MDX4-4210 silicone was used as parameter of comparison. Specimens (120 circular and 160 dumbbell-shaped) were obtained for each material, from metal cutting molds, which were divided into 4 groups: IP - intrinsic pigmentation (makeup powder); OP - opacifier (barium sulfate, BaSO4); IPO - IP + OP association; WP - without adding IP or OP. Then, the specimens were randomly divided into 3 subgroups to aging by exposure to natural light (NL, n = 10), ultraviolet light (UV, n = 10) and without light (C, n = 10). The experimental period was 12 months. The color change was observed with spectrocolorimeter and CIE L*a*b* system. For hardness we used a Shore A durometer and the analysis of tensile strength was performed in a universal testing machine. The quantitative response variables were measured immediately after obtaining the specimens and after the experimental period. The surface analysis was performed by scanning electron microscopy (SEM) and the chemical composition of silicones, by energy dispersive spectroscopy (EDS). Data were submitted to ANOVA and Tukey\'s test (p <0.05). SEM and EDS results were presented in pictures and graphics. There was interaction between all factors (p <0.05) and both materials varied depending on the pigmentation and aging methods. For color change, the experimental silicone (BS) showed the lowest color variations. Analyzing the silicones due to the pigmentation, the MDX showed higher variation with the WP and OP specimens aged in natural light and UV light. For BS, there was significant change in the color of the WP and OP specimens only after aging for NL. The two materials presented an increase in hardness front of all conditions, and the BS silicone showed the greatest variation. The experimental silicone showed superior tensile strength to MDX in all situations. The MDX was not affected in tensile strength by any pigmentation or aging, except for the group pigmented with makeup powder and aged by UV, where there was an increase of resistance. As to BS silicone, the highest tensile strength values were found for the IP and IPO in all age groups. It can be considered that the experimental material showed favorable results regarding color change, Shore A hardness and tensile strength for clinical use in maxillofacial prosthesis. The association of intrinsic pigmentation through makeup powder and opacifier, protected silicone of color change and promoted acceptable changes in mechanical properties of the materials. All the aging processes promoted changes in material properties.

Page generated in 0.1078 seconds