• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Reliability of the calculated maximal lactate steady state in amateur cyclists

Adam, Jennifer, Oehmichen, Matthias, Oehmichen, Eva, Rother, Janine, Müller, Ulrike Maria, Hauser, Thomas, Schulz, Henry 13 July 2015 (has links) (PDF)
Abstract provided by Publisher Complex performance diagnostics in sports medicine should contain maximal aerobic and maximal anaerobic performance. The requirements on appropriate stress protocols are high. To validate a test protocol quality criteria like objectivity and reliability are necessary. Therefore, the present study was performed in intention to analyze the reliability of maximal lactate production rate (VLamax) by using a sprint test, maximum oxygen consumption (VO2max) by using a ramp test and, based on these data, resulting power in calculated maximum lactate-steady-state (PMLSS) especially for amateur cyclists. All subjects (n=23, age 26 ± 4 years) were leisure cyclists. At three different days they completed first a sprint test to approximate VLamax. After 60 min of recreation time a ramp test to assess VO2max was performed. The results of VLamax-test and VO2max-test and the body weight were used to calculate PMLSS for all subjects. The intra class correlation (ICC) for VLamax and VO2max was 0.904 and 0.987, respectively, coefficient of variation (CV) was 6.3 % and 2.1 %, respectively. Between the measurements the reliable change index of 0.11 mmol∙l-1∙s-1 for VLamax and 3.3 ml∙kg-1∙min-1 for VO2max achieved significance. The mean of the calculated PMLSS was 237 ± 72 W with an RCI of 9 W and reached with ICC = 0.985 a very high reliability. Both metabolic performance tests and the calculated PMLSS are reliable for leisure cyclists.
2

Reliability of the calculated maximal lactate steady state in amateur cyclists

Adam, Jennifer, Oehmichen, Matthias, Oehmichen, Eva, Rother, Janine, Müller, Ulrike Maria, Hauser, Thomas, Schulz, Henry 13 July 2015 (has links)
Abstract provided by Publisher Complex performance diagnostics in sports medicine should contain maximal aerobic and maximal anaerobic performance. The requirements on appropriate stress protocols are high. To validate a test protocol quality criteria like objectivity and reliability are necessary. Therefore, the present study was performed in intention to analyze the reliability of maximal lactate production rate (VLamax) by using a sprint test, maximum oxygen consumption (VO2max) by using a ramp test and, based on these data, resulting power in calculated maximum lactate-steady-state (PMLSS) especially for amateur cyclists. All subjects (n=23, age 26 ± 4 years) were leisure cyclists. At three different days they completed first a sprint test to approximate VLamax. After 60 min of recreation time a ramp test to assess VO2max was performed. The results of VLamax-test and VO2max-test and the body weight were used to calculate PMLSS for all subjects. The intra class correlation (ICC) for VLamax and VO2max was 0.904 and 0.987, respectively, coefficient of variation (CV) was 6.3 % and 2.1 %, respectively. Between the measurements the reliable change index of 0.11 mmol∙l-1∙s-1 for VLamax and 3.3 ml∙kg-1∙min-1 for VO2max achieved significance. The mean of the calculated PMLSS was 237 ± 72 W with an RCI of 9 W and reached with ICC = 0.985 a very high reliability. Both metabolic performance tests and the calculated PMLSS are reliable for leisure cyclists.

Page generated in 0.1408 seconds