• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 158
  • 5
  • Tagged with
  • 163
  • 106
  • 92
  • 67
  • 60
  • 41
  • 39
  • 38
  • 36
  • 36
  • 35
  • 35
  • 35
  • 34
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Estratégias de controle digital a parâmetros fixos e supervisionados por lógica fuzzy aplicadas na melhoria do desempenho de sistemas elétricos de potência: resultados simulados e com experimentação em um micro gerador de energia

MOUTINHO, Marcelo Nascimento 30 April 2014 (has links)
Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-05T18:13:48Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstrategiasControleDigital.pdf: 13991215 bytes, checksum: 031550b79d39024d06a11bd969ea2497 (MD5) / Rejected by Edisangela Bastos (edisangela@ufpa.br), reason: on 2017-10-10T17:05:51Z (GMT) / Submitted by Hellen Luz (hellencrisluz@gmail.com) on 2017-10-16T15:40:15Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstrategiasControleDigital.pdf: 13991215 bytes, checksum: 031550b79d39024d06a11bd969ea2497 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-11-14T14:38:48Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstrategiasControleDigital.pdf: 13991215 bytes, checksum: 031550b79d39024d06a11bd969ea2497 (MD5) / Made available in DSpace on 2017-11-14T14:38:48Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_EstrategiasControleDigital.pdf: 13991215 bytes, checksum: 031550b79d39024d06a11bd969ea2497 (MD5) Previous issue date: 2014-04-30 / Este trabalho apresenta os resultados, simulados e com experimentação, obtidos nos estudos relacionados ao projeto e à implementação de estratégias avançadas de controle digital preditivo do tipo Generalized Predictive Control e supervisionado por lógica fuzzy, aplicadas ao controle e auxílio na melhoria da estabilidade de sistemas elétricos de potência. Uma das principais contribuições deste trabalho é de natureza prática já que a avaliação de uma parte das estratégias de controle preditivo propostas será realizada por meio de testes em um sistema de potência real e de escala reduzida. Outras contribuições do trabalho incluem: a) o desenvolvimento e a validação de um simulador computacional de sistemas de potência utilizado para avaliar dinamicamente o comportamento das estruturas de controle propostas quando o sistema de potência estudado é submetido a contingências operacionais comumente observadas durante sua operação; b) a montagem de um protótipo de sistema de potência real e de escala reduzida utilizado nos ensaios de avaliação de uma parte das estratégias de controle preditivo propostas. O protótipo de sistema de potência, formado por um motor de corrente contínua acoplado a um gerador síncrono de polos salientes conectado a um sistema de potência de escala comercial por uma pequena linha de transmissão, foi montado no Centro de Tecnologia da ELETROBRAS-ELETRONORTE (LACEN), localizado em Belém, Pará. Com os recursos deste protótipo, é possível avaliar e validar estratégias avançadas de controle, monitoração e manutenção preditiva aplicadas às máquinas elétricas rotativas em operação na ELETROBRAS-ELETRONORTE. / This thesis presents the experimental and simulated results obtained in the project and implementation of Generalized Predictive Control, an advanced digital predictive control technique, and fuzzy logic, applied to control and improvement of the stability of electric power systems. One of the main contributions of this thesis is of pratical nature, since a part of the proposed predictive control strategies were experimentaly avaliated by real avaliation tests. These tests are realized with a small scale real power system. There are other contributions like these: a) the project and validation of a computational power system simulator used to evaluate the behavior of the proposed control structures when operational contingencies, commonly observed in normal operation of the power system, are simulated; b) assembly a prototype of a small scale real electric power system used to evaluate a part of the proposed predictive control techniques. The assembled power system prototype is formed by two electric machines: a DC motor and a salient-pole synchronous generator. These two machines are mechanicaly coupled and connected to a commercial power system through a small transmission line simulator. The prototype was assembled at the Centro de Tecnologia da ELETROBRAS-ELETRONORTE (LACEN), located in Belém, Pará, Brazil. Using the prototype's features, it is possible to evaluate and validate advanced monitoring and control strategies. After these avaliations, these strategies can be used as predictive maintenance tools for the rotating electrical machines in operation at ELETROBRAS-ELETRONORTE.
152

Impactos na qualidade da energia elétrica provenientes do rápido crescimento da demanda no Sudeste do Estado do Pará

ESTEVES, Eduardo Augusto Cardoso 15 March 2012 (has links)
Submitted by Samira Prince (prince@ufpa.br) on 2012-09-25T14:32:24Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ImpactosQualidadeEnergia.pdf: 1971120 bytes, checksum: 2908c7316fcee52419ff96183b767ded (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2012-09-27T12:17:59Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ImpactosQualidadeEnergia.pdf: 1971120 bytes, checksum: 2908c7316fcee52419ff96183b767ded (MD5) / Made available in DSpace on 2012-09-27T12:17:59Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_ImpactosQualidadeEnergia.pdf: 1971120 bytes, checksum: 2908c7316fcee52419ff96183b767ded (MD5) Previous issue date: 2012 / Nos últimos anos, o desenvolvimento sócio econômico da Região Sudeste do Estado do Pará, tem sido causado principalmente pela exploração e processamento industrial de minérios, que agregado ao crescimento populacional, tem gerado grande evolução na demanda do consumo de energia elétrica, devido à instalação cada vez mais crescente de novas cargas industriais, comerciais, residenciais e rurais monofásicas. Todo esse aumento de carga já está impactando diretamente o desempenho das subestações distribuidoras da Concessionária de Energia Elétrica, no que tange a manifestação de distúrbios de regime permanente causados por harmônicas, tais como zumbidos em transformador de força e rompimento de condutores de média tensão. Estes distúrbios são apresentado em um estudo de caso envolvendo as Subestações (SE´s) Itacaiúnas e Itupiranga. Para comprovar a nocividade desses distúrbios nessas SE´s, foram realizadas campanhas de medição para obtenção de resultados práticos e, então, executadas simulações envolvendo estudos de curtocircuito, fluxo de carga e propagação de harmônicos, de forma a se obter um diagnóstico analítico sobre as situações encontradas e assim, ser possível emitir recomendações para a mitigação dos problemas detectados. Este trabalho será de grande valia à Concessionária de Energia Elétrica, podendo ser tomado como uma das referências para estudos de qualidade de energia elétrica, em outras subestações, além de dar embasamento experimental às futuras cobranças da ANEEL, com relação à implantação dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST). / In the recent years, the social and economical development in the Southeast of the State of Pará has been mainly caused by the exploitation and processing of mineral industries, which added to the population growth, has generated a high increase in the demand of electric energy and consumption due to the increasing installation of new industrial, commercial, residential and rural single-phase charges. This global increase is impacting directly the performance of distribution of electric utility, which can be expressed by the permanent disturbances caused by harmonics, such as buzzing in the power transformer and disruption of medium voltage conductors. These disturbances will be presented in a study of case involving the Substations (SE’s) Itacaiúna and Itupiranga. To prove how they can be harmful in these SE’s, campaigns of measurement were performed to obtain practical results and then, to perform studies involving simulations of short-circuit, load flow and spreading of harmonics in order to obtain an analytical diagnostic about the situations found and thus to issue recommendations to solve the problems identified. This study will provide a valuable support to the Concessionaire of Energy and it may be taken as a reference to the study of Power Quality in other substations, in addition to experimental basis for future charges from ANEEL, regarding the implementation of procedures in Electric Power Distribution National Electric System (PRODIST).
153

Sistema de controle baseado em lógica fuzzy para regulagem de temperatura em aquecedor de óleo térmico da planta de anodo verde da Albrás

ALMEIDA, José Guilherme Castro de 23 December 2011 (has links)
Submitted by Samira Prince (prince@ufpa.br) on 2012-10-08T14:38:40Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_SistemaControleBaseado.pdf: 3210601 bytes, checksum: 5105571d91a2692c89f007b995429652 (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2012-10-08T15:29:04Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_SistemaControleBaseado.pdf: 3210601 bytes, checksum: 5105571d91a2692c89f007b995429652 (MD5) / Made available in DSpace on 2012-10-08T15:29:04Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Dissertacao_SistemaControleBaseado.pdf: 3210601 bytes, checksum: 5105571d91a2692c89f007b995429652 (MD5) Previous issue date: 2011 / Neste trabalho são apresentados os resultados de uma técnica que permitiu implementar a estratégia de controle de temperatura do aquecedor de óleo térmico da fabrica de Anodo Verde da Albrás Alumínio Brasileiro S/A. No projeto utilizou-se um sistema hierarquizado baseado em conjuntos e lógica Fuzzy. O uso dessa metodologia fez com que o sistema fosse capaz de reagir adequadamente diante das variações do ponto de operação do aquecedor, pois o controle Fuzzy exibe algumas características do aprendizado humano, sendo considerado um exemplo de inteligência artificial. O aquecedor de óleo térmico é fundamental no processo de fabricação de blocos inódicos, utilizados como pólo positivo no processo de eletrólise na obtenção do alumínio primário. O sistema de óleo térmico aquece os misturadores e pré-aquecedor de coque, mantendo a temperatura desses equipamentos dentro dos limites estabelecidos pela engenharia de processo. A variável temperatura impacta diretamente na energia de mistura da pasta e na qualidade do produto final, que é o bloco anódico. A metodologia apresentada permitiu alcançar um controle de temperatura que atendeu satisfatoriamente os parâmetros de processo. O programa foi desenvolvido em linguagem ladder é executado em controladores lógicos programáveis (CLP’S) da Rockwell Automation. O controle já está em plena operação nas fábricas de anodos e os resultados obtidos demonstram a eficácia e viabilidade do sistema, que futuramente estará sendo implementado no controle de outros equipamentos da Albrás. / This work presents the results of a fuzzy control strategy to regulate the temperature of the heater thermal oil, in the Anode Green process at Albrás Aluminum Brasileiro S/A factory. The use of this methodology has resulted in the system being able to react adequately against of the variations on the point of operation of the heater, because the Fuzzy control displays some characteristics of human learning. The heater thermal oil equipment is fundamental in the process of manufacture of blocks butts, used as positive pole in the process of electrolysis in the acquisition of primary aluminum. The system of thermal oil warms the mixers and pre-heating of coke, keeping the temperature of the equipment within the limits established by process engineering. The variable temperature impacts directly in the energy mix of the pulp and the quality of the final product, which is block anode. The methodology presented allowed to reach a temperature control that satisfactorily achieved the process parameters. The program was developed in language scada is executed in programmable logic controllers (PLC'S) of Rockwell Automation. The methodology presented allowed to reach a temperature control that satisfactorily achieved the process parameters. The control is already in full operation at the plants of anodes and the results obtained demonstrate the effectiveness and viability of the system, which in future will be implemented in the control of other equipment of Albras.
154

Identificação de correntes de inrush na proteção diferencial de transformadores de potência através do gradiente da corrente diferencial e de mapas auto-organizáveis

ALENCAR, Raidson Jenner Negreiros de 10 June 2013 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2014-01-13T19:13:15Z No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_IdentificacaoCorrentesInrush.pdf: 2054419 bytes, checksum: 36597eb5c3f5ca05153702c4e53b98db (MD5) / Approved for entry into archive by Ana Rosa Silva(arosa@ufpa.br) on 2014-01-15T13:17:40Z (GMT) No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_IdentificacaoCorrentesInrush.pdf: 2054419 bytes, checksum: 36597eb5c3f5ca05153702c4e53b98db (MD5) / Made available in DSpace on 2014-01-15T13:17:40Z (GMT). No. of bitstreams: 2 license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Tese_IdentificacaoCorrentesInrush.pdf: 2054419 bytes, checksum: 36597eb5c3f5ca05153702c4e53b98db (MD5) Previous issue date: 2013 / A principal dificuldade encontrada na proteção diferencial de transformadores de potência é a correta distinção entre as correntes de inrush e as correntes de faltas internas. Tradicionalmente os relés diferenciais executam esta tarefa utilizando a técnica de restrição por harmônicos baseada na premissa de que as correntes de inrush possuem alta concentração de componentes harmônicas de segunda ordem, contudo essa técnica nem sempre é eficaz. O presente trabalho tem como objetivo apresentar a proposta de duas novas metodologias capazes de realizar a identificação e distinção entre as correntes de inrush das correntes de faltas internas na proteção diferencial de transformadores de potência através de metodologias que não dependem do conteúdo de harmônicos do sinal da corrente diferencial. A primeira metodologia proposta, denominada de método do gradiente da corrente diferencial, é baseada no comportamento do vetor gradiente, obtido através da diferenciação numérica do sinal da corrente diferencial. O critério de distinção utilizado é baseado no desvio padrão do ângulo do vetor gradiente que apresenta comportamento diferenciado para correntes de inrush e correntes de curto-circuito. A segunda metodologia proposta é baseada na capacidade de reconhecimento e classificação de padrões das redes neurais de Mapeamento Auto-organizável de Kohonen. Como padrão de entrada e de treinamento da rede neural é utilizado um vetor contendo quatro níveis do espectro do desvio padrão do ângulo do vetor gradiente da corrente diferencial nas três fases do transformador de potência. A eficácia dos métodos foi testada através da simulação de diversas situações de faltas internas e correntes de inrush, incluindo situações de “Sympathetic Inrush”, em um transformador de potência usando o software EMTP/ATP e através da implementação do algoritmo em MATLAB®, apresentando resultados altamente promissores. / A principal dificuldade encontrada na proteção diferencial de transformadores de potência é a correta distinção entre as correntes de inrush e as correntes de faltas internas. Tradicionalmente os relés diferenciais executam esta tarefa utilizando a técnica de restrição por harmônicos baseada na premissa de que as correntes de inrush possuem alta concentração de componentes harmônicas de segunda ordem, contudo essa técnica nem sempre é eficaz. O presente trabalho tem como objetivo apresentar a proposta de duas novas metodologias capazes de realizar a identificação e distinção entre as correntes de inrush das correntes de faltas internas na proteção diferencial de transformadores de potência através de metodologias que não dependem do conteúdo de harmônicos do sinal da corrente diferencial. A primeira metodologia proposta, denominada de método do gradiente da corrente diferencial, é baseada no comportamento do vetor gradiente, obtido através da diferenciação numérica do sinal da corrente diferencial. O critério de distinção utilizado é baseado no desvio padrão do ângulo do vetor gradiente que apresenta comportamento diferenciado para correntes de inrush e correntes de curto-circuito. A segunda metodologia proposta é baseada na capacidade de reconhecimento e classificação de padrões das redes neurais de Mapeamento Auto-organizável de Kohonen. Como padrão de entrada e de treinamento da rede neural é utilizado um vetor contendo quatro níveis do espectro do desvio padrão do ângulo do vetor gradiente da corrente diferencial nas três fases do transformador de potência. A eficácia dos métodos foi testada através da simulação de diversas situações de faltas internas e correntes de inrush, incluindo situações de “Sympathetic Inrush”, em um transformador de potência usando o software EMTP/ATP e através da implementação do algoritmo em MATLAB®, apresentando resultados altamente promissores.
155

Avaliação de estratégias de controle de potência reativa de aerogeradores síncronos em redes elétricas

NASCIMENTO, André Cavalcante do 11 2009 (has links)
Submitted by Irvana Coutinho (irvana@ufpa.br) on 2011-03-30T14:08:53Z No. of bitstreams: 2 NASCIMENTO, Andre Cavalcante do PPGEngenharia Elétrica tese.pdf: 2273415 bytes, checksum: 499dfcfe91476179f87605f7f44906d5 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) / Made available in DSpace on 2011-03-30T14:08:53Z (GMT). No. of bitstreams: 2 NASCIMENTO, Andre Cavalcante do PPGEngenharia Elétrica tese.pdf: 2273415 bytes, checksum: 499dfcfe91476179f87605f7f44906d5 (MD5) license_rdf: 22876 bytes, checksum: 0a4e855daae7a181424315bc63e71991 (MD5) Previous issue date: 2009 / No presente trabalho é avaliada uma metodologia de injeção de potência reativa em redes elétricas durante afundamentos de tensão provocados por curto-circuito, em parques eólicos interligados, adotada em alguns países com maturidade tecnológica na produção de energia eólica. Nos estudos desenvolvidos, foi utilizado o aerogerador síncrono a imã permanente com conversor pleno em função da grande controlabilidade do conversor interligado à rede e por possuir elevada capacidade de fornecimento de potência reativa, comparada a outras tecnologias de aerogeradores. No Brasil, os requisitos de interligação de parques eólicos as redes elétricas, definido pelo Operador Nacional do Sistema, ainda não estipula a necessidade de adoção de tal metodologia durante defeitos na rede elétrica, apenas especifica a curva de capacidade de afundamentos de tensão que os aerogeradores devem seguir para evitar o desligamento frente a afundamentos de tensão. Os critérios de proteção do aerogerador síncrono são avaliados a partir de simulações de curto-circuito em uma rede de teste adotando-se os requisitos do Brasil, sem injeção de potência reativa, sendo comparados com o de outros países que adotam curvas de injeção de potência reativa. / In the present work a methodology of reactive power injection in electric grids during voltage dips provoked by short-circuit, in connected wind farms, adopted at some countries with technological maturity in the production of wind energy in the world is evaluated. In the developed studies, the direct drive synchronous wind generator was used with full converter due to the high controllability of the converter connected to the electric grid and for possessing high capacity of reactive power supply, compared to other wind generators technologies. In Brazil, the grid code to connect wind farms to the electric grids, defined by the National Operator of the Electrical System, doesn't stipulate yet the need of adoption of such methodology during faults in the electric grid. It just specifies the ride through apability curve for voltage dips that the wind generators should follow to avoid the trip of the undervoltage relay. Criteria of the synchronous wind generators protection are evaluated starting from short-circuit simulations in a test grid with adoption of the Brazilian grid code, without reactive power injection, being compared with those of other countries that adopt reactive power injection curves. / IFPA - Instituto Federal de Educação, Ciência e Tecnologia do Pará
156

Análise do impacto de conversores de frequência na qualidade da energia do sistema de distribuição de uma indústria de petróleo

MAGALHÃES, Christiane Marques Sousa de 06 October 2010 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2012-04-13T18:54:52Z No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Edisangela Bastos(edisangela@ufpa.br) on 2012-04-13T18:56:10Z (GMT) No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-04-13T18:56:10Z (GMT). No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2010 / Apresenta-se neste trabalho uma análise da qualidade da energia do sistema de distribuição de uma indústria de petróleo, de modo a avaliar o impacto da instalação de conversores de frequência no que diz respeito ao fenômeno de distorção harmônica. Os dados de distorção harmônica de tensão foram coletados através de duas medições com duração de sete dias consecutivos, sendo uma realizada antes e outra depois da instalação dos conversores de frequência. Adicionalmente, um estudo computacional utilizando o PTW (Power Tools for Windows) é apresentado com o intuito de simular condições futuras de instalação de novos conversores de frequência e de avaliar a influência dos bancos de capacitores na amplificação da distorção harmônica no sistema de distribuição. / In this work, it is presented an analysis of the distribution system power quality of an oil industry in order to evaluate the impact of the installation of frequency converters regarding the harmonic distortion. The harmonic distortion data were collected through two measurements over a period of seven consecutive days, one performed before and other after the installation of frequency converters. Additionally, a computational study using PTW (Power Tools for Windows) is presented in order to simulate future conditions of new frequency converters installation and to analyse the influence of capacitor banks in the amplification of distribution system harmonic distortion.
157

Metodologia de auxílio na tomada de decisão na formação de conjuntos de unidades consumidoras de energia elétrica

SANTOS, Fábio Corrêa dos 08 October 2010 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2012-04-13T22:25:01Z No. of bitstreams: 2 Dissertacao_MetodologiaAuxilioTomada.pdf: 1746611 bytes, checksum: c217fec4c01b56932d1ed727804ec9e8 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Edisangela Bastos(edisangela@ufpa.br) on 2012-04-13T22:25:56Z (GMT) No. of bitstreams: 2 Dissertacao_MetodologiaAuxilioTomada.pdf: 1746611 bytes, checksum: c217fec4c01b56932d1ed727804ec9e8 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-04-13T22:25:56Z (GMT). No. of bitstreams: 2 Dissertacao_MetodologiaAuxilioTomada.pdf: 1746611 bytes, checksum: c217fec4c01b56932d1ed727804ec9e8 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2010 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / A edição dos procedimentos de distribuição de energia elétrica (PRODIST) confirmou a análise comparativa entre empresas de distribuição de energia elétrica estabelecida pela Resolução 024/2000 como base para o estabelecimento das metas dos indicadores de continuidade DEC (Índice de Duração Equivalente de Interrupção por Consumidor) e FEC (Índice de Frequência Equivalente de Interrupção por Consumidor). O estabelecimento das metas é influenciado diretamente pela definição dos conjuntos de unidades consumidoras das empresas de distribuição de energia elétrica, portanto, é de interesse das empresas distribuidoras uma boa definição desses conjuntos. Este trabalho apresenta o desenvolvimento de uma metodologia baseada em técnicas de aprendizado de máquina que auxilie as empresas de distribuição de energia elétrica na tomada de decisão da definição de conjuntos de unidades consumidoras objetivando melhor compatibilidade das metas para os indicadores de DEC e FEC com a realidade dos conjuntos em relação às características ambientais e de infra-estrutura da área de concessão da empresa distribuidora. / The issue of Proceedings of Electric Power Distribution (PRODIST) confirmed the comparative analysis of the distribution companies of electricity established by Resolution 024/2000 as the basis for establishing the goals of continuity indicators DEC (Costomer Average Duration Interruption Index) and FEC (Costomer Average Frequency Interruption Index). The setting of targets is directly influenced by the definition of the sets of consumer units of the distribution companies of electricity is therefore of interest to the distribution companies a good definition of these sets. This work presents the development of a methodology based on machine learning techniques to assist companies in electric power distribution in decision making of the definition of sets of consumers units aimed at improving compatibility of the goals for the indications of DEC and FEC with reality assemblies in relation to environmental characteristics and of infrastructure of the concession area of the distribution company.
158

Ferramentas para gestão estratégica da engenharia de manutenção: uma aplicação prática do MASP

SANTOS, Jackson Freitas 04 July 2012 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-02-03T18:29:41Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_FerramentasGestaoEstrategica.pdf: 2360127 bytes, checksum: 05758293a4fa8d73bf89e8a3f1d54318 (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-02-04T12:26:16Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_FerramentasGestaoEstrategica.pdf: 2360127 bytes, checksum: 05758293a4fa8d73bf89e8a3f1d54318 (MD5) / Made available in DSpace on 2015-02-04T12:26:16Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Dissertacao_FerramentasGestaoEstrategica.pdf: 2360127 bytes, checksum: 05758293a4fa8d73bf89e8a3f1d54318 (MD5) Previous issue date: 2012 / Eletronorte - Centrais Elétricas do Norte do Brasil S/A / Normalmente, os programas de manutenções implementados nas empresas de geração, transmissão e distribuição de energia elétrica buscam evitar que falhas venham a provocar a retirada do equipamento do sistema elétrico, o que significa grandes perdas financeiras, seja pela diminuição do faturamento, seja pelo pagamento de multas a agência reguladora, alem da diminuição da confiabilidade do sistema. Para evitar esses inconvenientes, a engenharia de manutencao lanca mao de ferramentas estrategicas para a gestao e solucoes dos problemas, visando a otimizacao, juntamente com circulo virtuoso de melhorias continuas nos processos de manutencao. Este trabalho tem por finalidade fazer uma analise da Metodologia de Analise e Solucao de Problemas (MASP), como ferramenta de gestao estrategica na busca e solucao de problemas no ambito da engenharia de manutencao. Para isso, inicialmente, apresenta-se uma serie de informacoes sobre a gestao da manutencao, bem como todo o arcabouco que envolve qualidade e ferramentas gerenciais. Com o capitulo que trata especificamente do MASP, tem-se uma nocao mais exata do quanto cada ferramenta e necessaria para que se possa desenvolver um bom trabalho, visto que ele retrata que essa metodologia nada mais e do que o somatorio de todas as ferramentas existentes, colocadas de maneira ordenada. Por fim, apresentam-se quatro estudos de casos, pelos quais pretendemos demonstrar a Metodologia de Analise e Solucao de Problemas e a aplicabilidade na gestão estratégica, com visão em resultados no ambiente da engenharia de manutenção no pilar das manutenções programadas e autônomas - MP/MA, no ambito da Divisãoo de Transmissão de Ji-Parana/RO - ORDJ, vinculada a Centrais Eletricas do Norte do Brasil (Eletronorte). Na conclusao, faz-se uma analise critica do uso da metodologia na prestação de serviços, baseada na aplicaão supracitada. / Typically, maintenance programs implemented in companies for generation, transmission and distribution of electricity that seek to avoid failure will cause the removal of equipment from the electrical system, which means large financial losses, either by decreased revenues, either by paying fines the regulatory agency, in addition to decreased system reliability. To avoid these drawbacks, the maintenance engineering makes use of strategic tools for the management of problems and solutions aimed at optimizing along with virtuous cycle of continuous improvement in maintenance processes. This study aims to make an analysis of the Methodology Analysis and Troubleshooting (MASP) as a strategic management tool to find and solve problems within the maintenance engineering. Thus initially presents a lot of information on the management of maintenance as well as the entire framework involving quality and management tools. With the chapter that deals specifically with MASP, have become a better sense of how each tool is required so that we can develop a good job, since it portrays that this methodology is nothing more than the sum of all existing tools placed in an orderly manner. Finally, we present four case studies where we intend to demonstrate the methodology Analysis and Troubleshooting (MASP) and applicability in strategic management vision into results in environmental engineering maintenance on the pillar of scheduled maintenance and autonomous - MP/MA within the Transmission Division Ji-Parana/RO - ADJR, linked to Power Plants in Northern Brazil (Eletronorte). In conclusion, it is a critical analysis of the methodology used in the provision of services, based on the above application.
159

Uso de técnicas de mineração de dados para a extração de indicação de falha na operação de hidrogeradores a partir de medidas de descargas parciais

PARDAUIL, Ana Carolina Neves 17 June 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-01-27T15:40:38Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-01-30T12:17:53Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5) / Made available in DSpace on 2017-01-30T12:17:53Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_TecnicasMineracaoDados.pdf: 5205222 bytes, checksum: 0ac0aceafcb8be8da514e3982160642b (MD5) Previous issue date: 2016-06-17 / Mediante estudos realizados pelo CIGRE em 2009, constatou-se que a fonte principal de falhas elétricas em hidrogeradores estão correlacionados a isolação elétrica. Devido a isto, monitorar as condições do enrolamento estatórico tornou-se primordial e um dos meios de se realizar este procedimento é através da medição e análise de descargas parciais, sendo este um dos métodos mais eficazes e seguros para análise do isolamento do estator do gerador. No entanto, apesar de possuírem padrões bem definidos, não é trivial encaixar os sinais obtidos nestes padrões, devido principalmente ao grande número e variedades de ocorrências de DPs. Este aumento no volume de dados obtidos foi devido a melhorias nos equipamentos e softwares do IMA-DP que viabilizou melhor planejamento e periodicidade nas medições. O uso de uma ferramenta que agilize este processo de identificação e diagnóstico das Descargas Parciais é proposto neste trabalho, baseado em técnicas de mineração dados utilizando árvores de decisão, que é uma solução para análise de grandes volumes de dados. No caso especifico aqui apresentado, utilizou-se 2435 medições provenientes da fase A de um dos hidrogeradores da Casa de Força 1 da Usina Hidrelétrica de Tucuruí, o que foi fundamental para validar o método, pois trata-se de dados reais do sistema. Foi utilizada uma abordagem híbrida (não-supervisionado/ supervisionado) para identificar padrões e posteriormente classifica-los dentre as formas conhecidas de DPs. Obteve-se respostas de classificação dos sinais de forma rápida e muito satisfatória, principalmente ao se converter os dados dos mapas estatísticos em histogramas de amplitude, conseguindo assim, clusters bem definidos e uma árvore de decisão que apresentou índices de acerto global na sua validação acima de 98%. / By studies conducted by CIGRE in 2009, it was found that the main source of hydro generator failures is correlated to the machine electrical insulation. Due to this fact, monitoring the stator winding conditions became an important supervising procedure. A very used practice to accomplish this supervision is through the measurement and analysis of partial discharges (PDs), being this practice one of the most effective and secure methods for analysis of generator stator insulation. However, although PDs have well-defined standards, it is not trivial to classify the obtained PDs signals in these patterns, mainly due to the large number and variety of PDs occurrences. Today, the significant increase in the amount of PDs data available was due to improvements in equipment and software for PDs monitoring, as for example the system IMA-DP, which has contributed to better planned and more frequent measurement campaigns. So, this work proposes the use of an intelligent tool to facilitate the process of identification and diagnosis of partial discharges, based on data mining techniques using decision trees (DT), which is a solution for analyzing large amount of data. In the specific case presented in this dissertation it was used 2,435 measurements obtained for phase A of a hydro generator of the Tucurui Hydro Plant, which was essential to validate the proposed method, because they represent real data obtained from the Hydro Plant operation. A hybrid approach (supervised/unsupervised) was used to identify and rank PDs patterns among the well-known forms of DPs. A fast and very satisfactory PDs classification procedure was achieved, especially when converting data from statistical maps into amplitude histograms, thus, obtaining well-defined clusters and a created decision tree that achieved global indices of accuracy above 98%.
160

Estudos dos efeitos das descargas atmosféricas nos índices de desempenho da subestação de Vila do Conde e subestação de Marabá

SANTOS, Luciano Silva dos 10 May 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-04-27T14:05:39Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-05-04T12:57:18Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) / Made available in DSpace on 2017-05-04T12:57:18Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Dissertacao_EstudosEfeitosDescargas.pdf: 3450211 bytes, checksum: fca30650fac216b6df30f8e2dc05f5a8 (MD5) Previous issue date: 2016-05-10 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este trabalho tem como objetivo apresentar os efeitos de descargas atmosféricas nos índices de desempenho na subestação de Vila do Conde (SE VDC) e de Marabá (SE MB), onde estão situadas na região norte, no estado do Pará, integrando o Sistema Norte - Nordeste de Transmissão da ELETRONORTE, estando interligadas às Usinas Hidrelétrica de Tucuruí (UHE Tucuruí). Foram estudadas, estabelecendo as relações entre as informações meteorológicas cedidas pelo SIPAM e dados fornecidos pelo centro de operações da Eletronorte no período de 2005 a 2013 de forma a determinar os efeitos nocivos das descargas atmosféricas, as quais são responsáveis pela intensificação de interrupções no fornecimento de energia elétrica. A análise por restrita à área de atuação da Eletronorte SE VDC e SE MB. O estudo desenvolvido evidência os desligamentos por descargas atmosféricas na linha de transmissão VDC/CASTANHAL de 230 KV e no disjuntor de 500 KV VCDJ7-08 e linha de transmissão MB/Imperatriz de 500 KV. Os resultados demonstram que a incidência de um raio pode causar surtos diretos e indiretos em linhas de transmissão e subestações de alta potência. Neste contexto justifica o estudo de formas eficientes de prevenção, sendo uma das finalidades deste trabalho. / This paper aims to present the effects of lightning in the performance indices in Vila do Conde substation (SE VDC) and Maraba (SE MB), which are situated in the north, in the state of Pará, integrating the North System - Eletronorte Transmission northeast, being connected to the Tucuruí Hydroelectric Power Plants (HPP Tucuruí). They were studied, establishing relations between the weather information provided by the SIPAM and data provided by central Eletronorte's operations in the period 2005-2013 in order to determine the harmful effects of lightning, which are responsible for the intensification of supply interruptions electricity. The analysis restricted to the area of operation of Eletronorte SE and SE VDC MB. The study developed evidence disconnections by lightning on transmission line VDC / CASTANHAL 230 KV and 500 KV breaker VCDJ7-08 and transmission line MB / Empress of 500 KV. The results demonstrate that a lightning strike may cause direct and indirect surges in transmission lines and high power substations. In this context it justifies the study of efficient forms of prevention, one of the purposes of this work.

Page generated in 0.0492 seconds