• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 26
  • 1
  • Tagged with
  • 27
  • 21
  • 20
  • 18
  • 16
  • 14
  • 12
  • 10
  • 10
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

A correlação entre os erros de retilineidade e angulares nas máquinas de medir a três coordenadas / The correlation between the straightness errors and angular errors in three coordinate measuring machines

Marques, Alessandro 29 March 1999 (has links)
O desempenho metrológico de uma Máquina de Medir a Três Coordenadas (MM3C) está relacionado com a sua capacidade de medir peças com a precisão requerida ou desejada. No entanto, como todo instrumento de medição, essas máquinas possuem erros que afetam as medições gerando o que se convencionou chamar de erros volumétricos. Tais erros podem ser obtidos através de modelos matemáticos que descrevem como os erros individuais de todos os componentes da MM3C se combinam por todo o volume de trabalho. Atualmente, no modelamento dos erros, adota-se a independência entre os erros individuais, entretanto, se analisada a geometria estrutural da máquina, verifica-se que existe dependência entre os erros de retilineidade e os erros angulares. O objetivo deste trabalho é expressar o erro angular em função do erro de retilineidade, possibilitando assim minimizar o número de calibrações necessárias e, consequentemente, o tempo de máquina parada requerido para o levantamento do seu comportamento metrológico. Para que se pudesse atingir o objetivo proposto, foram levantados os erros de retilineidade e os angulares de uma Máquina de Medir a Três Coordenadas da marca Brown & Sharp do tipo Ponte Móvel. Com esses dados e o conhecimento da geometria da máquina, os erros angulares foram equacionados, calculados e comparados com os obtidos experimentalmente. / The metrological performance of a Three Coordinate Measuring Machines (CMM) is related to the capacity of measuring workpieces with a required precision. As every measurement instrument, these machines undergo the effects of internal and external factors that affect the measurement, generating what has been denominated as volumetric errors. Such errors can be obtained through a mathematical model that simulates how the individual errors of the CMM are combined and propagated to any point within the machine working volume. Usually, the independence among the individual errors is adopted when the machine error model is built. However, if the machine geometry is analyzed, the dependence between the straightness error and the angular error can be noted. The objective of this work is to express the angular error as a function of the straightness error. The formulation proposed in this work to express this correlation minimizes the number of calibrations necessary to evaluate the machine behavior. A Brown & Sharp Moving Bridge Coordinate Measuring Machine was used for the experimental evaluation. With this data set and knowing the machine geometry, a mathematical expression relating straightness and angular error was obtained. The calculated error values were then compared with the errors experimentally measured.
12

Calibração indireta de máquina de medir por coordenadas utilizando esquadro mecânico de esferas / Indirect calibration of a coordinate measuring machine using mechanical ball square

Vieira, Alessandro David 15 July 2009 (has links)
Com o crescimento industrial e tecnológico nas últimas décadas, as indústrias passaram a oferecer produtos customizados, ou seja, desenvolvidos com tolerâncias geométricas cada vez mais apertadas e geometrias cada vez mais complexas. Com isso, as máquinas de medir por coordenadas (MMC) vêm tornando-se instrumentos essenciais no ambiente industrial. A MMC é extremamente versátil o que possibilita a medição das mais diversas características geométricas e dimensionais. Padrões para calibração de MMC foram sugeridos e colocados em uso através dos anos, com a finalidade de utilizá-los em testes de aceitação e verificação periódica dos erros e da incerteza de medição de MMC. Novos artefatos para a calibração indireta de MMC visam melhorar os procedimentos de calibração para uso em sistemas de compensação de erros. Diante do exposto acima, este trabalho tem como objetivo desenvolver um procedimento de calibração indireta de MMC com o esquadro de esferas aliado a um modelo reduzido de sintetização de erros (MRSE) para uso em um Sistema de Compensação de Erros. O procedimento possibilita maior rapidez na obtenção dos valores e comportamentos dos erros quando comparado com outros procedimentos de calibração indireta. O procedimento proposto tem como vantagem o uso de um esquadro de esferas para medir todos os termos das equações das componentes do erro volumétrico, nas direções X, Y e Z de uma MMC. / With the technological and industrial growth in recent decades, the industries began to offer customized products, that is, products that fit individual specifications and often present increasingly tight tolerances and increasingly complex geometries. Therefore, the coordinate measuring machines (CMMs) have become an essential tool in the industrial environment. The CMM is very versatile since it allows the measurement of several geometric and dimensional features at once. Different standards for the calibration of CMMs were suggested and put into use through the years. This type of standard is traditionally used in acceptance tests and periodic verifications of the CMMs and in the evaluation of measurement uncertainties. New artifacts for indirect calibration of CMMs are proposed to allow the development of better procedures of error evaluation and compensation. Considering the above, this work aims to develop a procedure for indirect calibration of CMMs using a mechanical ball square combined with a reduced model of synthesis of Errors (MRSE). As a result, a compensation system for CMM errors is obtained. The procedure allows a faster evaluation of the values and behaviors of errors when compared with other indirect calibration procedures. Additionally, the proposed procedure has the advantage of using a single artifact to measure all the components of the volumetric error in the directions X, Y and Z of a CMM.
13

Calibração indireta de máquina de medir por coordenadas utilizando esquadro mecânico de esferas / Indirect calibration of a coordinate measuring machine using mechanical ball square

Alessandro David Vieira 15 July 2009 (has links)
Com o crescimento industrial e tecnológico nas últimas décadas, as indústrias passaram a oferecer produtos customizados, ou seja, desenvolvidos com tolerâncias geométricas cada vez mais apertadas e geometrias cada vez mais complexas. Com isso, as máquinas de medir por coordenadas (MMC) vêm tornando-se instrumentos essenciais no ambiente industrial. A MMC é extremamente versátil o que possibilita a medição das mais diversas características geométricas e dimensionais. Padrões para calibração de MMC foram sugeridos e colocados em uso através dos anos, com a finalidade de utilizá-los em testes de aceitação e verificação periódica dos erros e da incerteza de medição de MMC. Novos artefatos para a calibração indireta de MMC visam melhorar os procedimentos de calibração para uso em sistemas de compensação de erros. Diante do exposto acima, este trabalho tem como objetivo desenvolver um procedimento de calibração indireta de MMC com o esquadro de esferas aliado a um modelo reduzido de sintetização de erros (MRSE) para uso em um Sistema de Compensação de Erros. O procedimento possibilita maior rapidez na obtenção dos valores e comportamentos dos erros quando comparado com outros procedimentos de calibração indireta. O procedimento proposto tem como vantagem o uso de um esquadro de esferas para medir todos os termos das equações das componentes do erro volumétrico, nas direções X, Y e Z de uma MMC. / With the technological and industrial growth in recent decades, the industries began to offer customized products, that is, products that fit individual specifications and often present increasingly tight tolerances and increasingly complex geometries. Therefore, the coordinate measuring machines (CMMs) have become an essential tool in the industrial environment. The CMM is very versatile since it allows the measurement of several geometric and dimensional features at once. Different standards for the calibration of CMMs were suggested and put into use through the years. This type of standard is traditionally used in acceptance tests and periodic verifications of the CMMs and in the evaluation of measurement uncertainties. New artifacts for indirect calibration of CMMs are proposed to allow the development of better procedures of error evaluation and compensation. Considering the above, this work aims to develop a procedure for indirect calibration of CMMs using a mechanical ball square combined with a reduced model of synthesis of Errors (MRSE). As a result, a compensation system for CMM errors is obtained. The procedure allows a faster evaluation of the values and behaviors of errors when compared with other indirect calibration procedures. Additionally, the proposed procedure has the advantage of using a single artifact to measure all the components of the volumetric error in the directions X, Y and Z of a CMM.
14

Correlação entre métodos de mensuração da adesão à higienização das mãos em unidade de terapia intensiva neonatal / Correlation between methods of measuring hand hygiene compliance in a neonate intensive care unit

Barbosa, Luciana Rezende 15 June 2010 (has links)
Introdução: A utilização de métodos simples e de baixo custo para se medir a adesão à higienização das mãos em serviços de saúde torna-se cada vez mais necessária, a fim de permitir a avaliação da qualidade da assistência prestada, dos investimentos realizados e da eficácia das intervenções objetivando o aumento da adesão à prática. Objetivo: Correlacionar o método indireto de medir a adesão à higienização das mãos com o método direto em uma unidade de terapia intensiva neonatal de um hospital público universitário em Belo Horizonte, Minas Gerais. Método: Estudo analítico de observação direta da higienização de mãos de profissionais e visitantes. Paralelamente, o número de higienizações de mãos obtido por meio de contadores eletrônicos instalados no interior dos dosadores de sabão neutro e gel alcoólico. A correlação entre os métodos foi analisada pelo diagrama de dispersão e pela regressão. Resultados: Foram observadas 7.324 oportunidades de higienização de mãos em 255 períodos de uma hora cada. Foi identificada uma correlação positiva moderada quando a variável resposta foi a porcentagem de adesão e uma correlação positiva forte quando a variável resposta foi o número de higienizações de mãos. Conclusões: A existência de uma concordância e uma correlação positiva entre os dois métodos significa a possibilidade da utilização de métodos indiretos para monitorar o aumento ou a diminuição da adesão à higienização das mãos. O monitoramento dessa importante prática de prevenção de infecções permite aos serviços de saúde aprimorar a qualidade do cuidado assistido, incentivo para a realização de melhorias, investigação de surtos e infra-estrutura física adequada / Introduction: The use of a simple and low cost method to measure hand hygiene compliance in health care services becomes more and more necessary to allow assessment of the quality of care, investments done and interventions effectiveness aiming to increase compliance. Objective: To correlate the indirect method of measuring hand hygiene compliance with the direct method in a neonate intensive care unit at a university public hospital in Belo Horizonte, Minas Gerais. Method: Analytical study of hand hygiene direct observation of health care workers and visitors. At the same time, the number of hand hygiene was obtained through the electronic counters device installed inside the alcohol and blend soap dispensers was obtained. Correlation between methods was analyzed using dispersion diagram and regression. Results: 7.324 hand hygiene opportunities were observed during 255 periods of one hour each one. Moderate positive correlation was identified when the dependent variable was percentage of compliance and a strong positive correlation when the dependent variable was the number of hand hygiene. Conclusions: The existence of the concordance and the positive correlation between the two methods means the possibility to use indirect methods to monitor hand hygiene compliance increase or decrease. The monitoring of this important practice of infection prevention allow the health care services to improve quality of care assessment, incentive for performance improvement, outbreak investigation, and infrastructure design
15

Correlação entre métodos de mensuração da adesão à higienização das mãos em unidade de terapia intensiva neonatal / Correlation between methods of measuring hand hygiene compliance in a neonate intensive care unit

Luciana Rezende Barbosa 15 June 2010 (has links)
Introdução: A utilização de métodos simples e de baixo custo para se medir a adesão à higienização das mãos em serviços de saúde torna-se cada vez mais necessária, a fim de permitir a avaliação da qualidade da assistência prestada, dos investimentos realizados e da eficácia das intervenções objetivando o aumento da adesão à prática. Objetivo: Correlacionar o método indireto de medir a adesão à higienização das mãos com o método direto em uma unidade de terapia intensiva neonatal de um hospital público universitário em Belo Horizonte, Minas Gerais. Método: Estudo analítico de observação direta da higienização de mãos de profissionais e visitantes. Paralelamente, o número de higienizações de mãos obtido por meio de contadores eletrônicos instalados no interior dos dosadores de sabão neutro e gel alcoólico. A correlação entre os métodos foi analisada pelo diagrama de dispersão e pela regressão. Resultados: Foram observadas 7.324 oportunidades de higienização de mãos em 255 períodos de uma hora cada. Foi identificada uma correlação positiva moderada quando a variável resposta foi a porcentagem de adesão e uma correlação positiva forte quando a variável resposta foi o número de higienizações de mãos. Conclusões: A existência de uma concordância e uma correlação positiva entre os dois métodos significa a possibilidade da utilização de métodos indiretos para monitorar o aumento ou a diminuição da adesão à higienização das mãos. O monitoramento dessa importante prática de prevenção de infecções permite aos serviços de saúde aprimorar a qualidade do cuidado assistido, incentivo para a realização de melhorias, investigação de surtos e infra-estrutura física adequada / Introduction: The use of a simple and low cost method to measure hand hygiene compliance in health care services becomes more and more necessary to allow assessment of the quality of care, investments done and interventions effectiveness aiming to increase compliance. Objective: To correlate the indirect method of measuring hand hygiene compliance with the direct method in a neonate intensive care unit at a university public hospital in Belo Horizonte, Minas Gerais. Method: Analytical study of hand hygiene direct observation of health care workers and visitors. At the same time, the number of hand hygiene was obtained through the electronic counters device installed inside the alcohol and blend soap dispensers was obtained. Correlation between methods was analyzed using dispersion diagram and regression. Results: 7.324 hand hygiene opportunities were observed during 255 periods of one hour each one. Moderate positive correlation was identified when the dependent variable was percentage of compliance and a strong positive correlation when the dependent variable was the number of hand hygiene. Conclusions: The existence of the concordance and the positive correlation between the two methods means the possibility to use indirect methods to monitor hand hygiene compliance increase or decrease. The monitoring of this important practice of infection prevention allow the health care services to improve quality of care assessment, incentive for performance improvement, outbreak investigation, and infrastructure design
16

BATIMETRIA DE PEQUENOS RESERVATÓRIOS ATRAVÉS DE METODOLOGIA CONVENCIONAL E ALTERNATIVA / BATHYMETRY SMALL RESERVOIRS BY CONVENTIONAL AND ALTERNATIVE METHODS

Bilhalva, Wagner Danton de Bittencourt 19 February 2013 (has links)
For legal use of artificial water reservatories, it is necessary liberation of competent authorities granting the request for water use. The application requires extensive information about the object to be measured. When the object of the measure is a reservatory, the information required is the volume of water mass stored. To quantify the depth value and then get the volume of water reservatory already constructed, the current methodologies using tools like electronic tachometer (season total), multibeam echo sounder and mono and remote sensing. This methods give informations about water quantity and quality, which increases practice bathymetry. Therefore the goal of this study is to develop a more practical and less expensive method of measure, using an alternative apparatus for bathymetric surveys in small reservatories. Therefore, we compared depths measures obtained by the conventional known and consolidated method tape using topographical surveys. This method obtains measurements with the sonar device Garmin Fishfinder 90, developed for fishing. The depth values obtained with both method sare compared statistically to evaluate the significance and degree of correlation between both methods (tape and sonar). We propose a model to estimate the correct depth with sonar observed. With this model it is possible to use sonar bathymetry for small reservatories, making it possible to execute bathymetric measure with less expensive cost. It is concluded that it is possible to use sonar bathymetry for small reservoirs, making it possible to execute more agile bathymetric much lower cost when compared with the use of echo sounder professional. / Para o uso legal da água de reservatórios artificiais, é necessário realizar junto ao órgão competente o pedido de outorga do uso da água, do qual esse pedido requer inúmeras informações sobre o objeto a ser outorgado. Quando o objeto de outorga é um reservatório, uma das informações solicitadas é o volume de massa d'água armazenado. Para quantificar o valor de profundidade e posteriormente obter o volume hídrico de reservatórios já construídos, as metodologias atuais utilizam instrumentos como taquímetro eletrônico (estação total), ecobatímetro de mono e multifeixe,sensoriamento remoto e trena que possibilitam obter informações quali-quantitavitas hídricas, o que encarece a prática da batimetria. Sendo assim o objetivo deste estudo foi desenvolver uma metodologia mais prática e de menor custo, com a utilização de um aparelho alternativo, para levantamentos batimétricos em reservatórios de pequeno porte. Para tanto, comparou-se medidas de profundidades obtidas através do método convencional conhecido e consolidado, que usa trena de levantamentos topográficos com medidas obtidas com o aparelho sonar Garmin Fishfinder 90, desenvolvido para pesca. Os valores de profundidade obtidos com ambos os métodos foram comparados estatisticamente, para avaliar a o grau de correlação e significância entre ambas as metodologias (trena e sonar). Foi criado um modelo de correção para a estimativa de profundidade observada com o sonar. Conclui-se que é possível utilizar o sonar, para batimetria em pequenos reservatórios, tornando possível a execução de levantamentos batimétricos mais ágeis a custos bem mais reduzidos quando comparado com o uso de ecobatímetro profissional.
17

Modelo reduzido de sintetização de erros para máquinas de medir a três coordenadas / not available

Renata Belluzzo Zirondi 27 March 2002 (has links)
Desde sua criação por Ferranti, cerca de 50 anos atrás, as tecnologias de projeto e de fabricação das Máquinas de Medir a Três Coordenadas evoluíram muito. Entretanto, ainda é possível fabricar equipamentos livres de erros. Para garantir a acuracidade das medições realizadas é necessário que se conheça tais erros e que rotinas de compensação sejam implementadas. O levantamento dos erros de qualquer equipamento é feito através de procedimentos de calibração. Entretanto, devido à complexidade das MM3Cs, ainda não existem procedimentos internacionalmente aceitos, por usuários e fabricantes, para avaliar o desempenho metrológico desses equipamentos. Técnicas normalizadas existentes, a exemplo, JIS B 7440 de 1987, B89.4.1 de 1997, VDI/VDE 2617 de 1986 entre outras, propõem testes de desempenho que na maioria das vezes superestimam os erros da MM3C. Além disso, dificultam a rastreabilidade para quaisquer condições de medição diferente daquelas em que foi realizado o teste. Assim, diante do exposto, este trabalho tem por objetivo principal apresentar um novo modelo de sintetização de erros para MM3Cs, o Modelo Reduzido de Sintetização de erros. Este modelo possui equações de sintetização, para Ex, Ey e Ez, reduzidas, em comparação à outros modelos conhecidos, necessita de pequeno tempo na calibração o que reduz o custo desta atividade, possibilita o diagnóstico das fontes de erros e garante a rastreabilidade dos erros calculados. / Since the introduction of coordinate measuring machines by Ferranti in late fifties, the CMM design and manufacturing technology have enormously developed. Nevertheless, it is stile impossible to produce mechanical devices that are exempted from errors. In order to ensure measurements accuracy, it becomes necessary to understand such errors and establish compensation routines. The errors survey of any piece of equipment is performed by means of calibration procedures. However, due to the complexity of CMMs, there are not, until the present time, procedures that are internationally accepted by uses and manufactures to evaluate the metrological performance of this sort of equipment. Current standardized techniques, for instance, JIS B 7440 from 1987, B89.4.1. from 1997, VDI/VDE 2617 from 1986, among others, propose performance tests that usually overestimate CMM errors. Furthermore, they obstruct traceability to whatever measurement condition that is different from the ones used to perform the test. This being the case, the aim of this work comprises the presentation of the new error sinthetization model. This model deals with sinthetization equations for Ex, Ey and Ez that are reduced if compared to other known models, requires short calibration periods, reducing its expenses, allow the determination of the sources of errors and ensures traceability of calculated errors.
18

A correlação entre os erros de retilineidade e angulares nas máquinas de medir a três coordenadas / The correlation between the straightness errors and angular errors in three coordinate measuring machines

Alessandro Marques 29 March 1999 (has links)
O desempenho metrológico de uma Máquina de Medir a Três Coordenadas (MM3C) está relacionado com a sua capacidade de medir peças com a precisão requerida ou desejada. No entanto, como todo instrumento de medição, essas máquinas possuem erros que afetam as medições gerando o que se convencionou chamar de erros volumétricos. Tais erros podem ser obtidos através de modelos matemáticos que descrevem como os erros individuais de todos os componentes da MM3C se combinam por todo o volume de trabalho. Atualmente, no modelamento dos erros, adota-se a independência entre os erros individuais, entretanto, se analisada a geometria estrutural da máquina, verifica-se que existe dependência entre os erros de retilineidade e os erros angulares. O objetivo deste trabalho é expressar o erro angular em função do erro de retilineidade, possibilitando assim minimizar o número de calibrações necessárias e, consequentemente, o tempo de máquina parada requerido para o levantamento do seu comportamento metrológico. Para que se pudesse atingir o objetivo proposto, foram levantados os erros de retilineidade e os angulares de uma Máquina de Medir a Três Coordenadas da marca Brown & Sharp do tipo Ponte Móvel. Com esses dados e o conhecimento da geometria da máquina, os erros angulares foram equacionados, calculados e comparados com os obtidos experimentalmente. / The metrological performance of a Three Coordinate Measuring Machines (CMM) is related to the capacity of measuring workpieces with a required precision. As every measurement instrument, these machines undergo the effects of internal and external factors that affect the measurement, generating what has been denominated as volumetric errors. Such errors can be obtained through a mathematical model that simulates how the individual errors of the CMM are combined and propagated to any point within the machine working volume. Usually, the independence among the individual errors is adopted when the machine error model is built. However, if the machine geometry is analyzed, the dependence between the straightness error and the angular error can be noted. The objective of this work is to express the angular error as a function of the straightness error. The formulation proposed in this work to express this correlation minimizes the number of calibrations necessary to evaluate the machine behavior. A Brown & Sharp Moving Bridge Coordinate Measuring Machine was used for the experimental evaluation. With this data set and knowing the machine geometry, a mathematical expression relating straightness and angular error was obtained. The calculated error values were then compared with the errors experimentally measured.
19

Modelos de sintetização plena e reduzida de erros em máquinas de medir por coordenadas / Synthesizing technique and reduced synthesizing technique of errors in coordinate measuring machines

Morais, César Augusto Galvão de 02 March 2012 (has links)
A atual competitividade da economia mundial exige um controle de qualidade sofisticado em indústrias de manufatura, pois, devido ao grande número de empresas do setor são constantes as exigências de melhorias na produção. Deste modo, sistemas de medição rápidos, precisos e flexíveis como a MMC (Máquina de Medir por Coordenada) são introduzidos junto ao processo produtivo e, no que se refere à inspeção dimensional, eles proporcionam os quesitos pretendidos. Como todas as máquinas, a MMC está suscetível a erros, o que resulta em valores errôneos de sua resposta de leitura. Neste contexto, o objetivo principal do trabalho é descrever uma metodologia para efetuar um levantamento de erros em uma MMC, equacionando e quantificando nas suas direções preferenciais os erros incidentes durante um procedimento de medição. O levantamento de erros foi realizado em uma MMC do tipo ponte móvel sob as formas, teórica e experimental. A metodologia aplicada sob a forma teórica foi elaborada pelo método reduzido de sintetização de erros e pelo método pleno de sintetização de erros. Para estas sintetizações foram desenvolvidos matematicamente modelos da máquina por meio de uma análise de sua estrutura e também utilizando a teoria das transformações homogêneas. O levantamento de erros sob a forma experimental, sintetização experimental de erros, foi realizado de forma plena, obtendo valores dos 21 erros individuais. Para este método, foi utilizado canhão laser de medição, conjunto de óticas de medição por interferometria, apalpador eletrônico, nível eletrônico, esquadro mecânico de granito, além de dispositivos de fixação. Por meio dos valores obtidos na sintetização experimental permitiu-se conhecer a influência dos erros na ponta da sonda de medição. Os resultados mostraram que o eixo \"Z\" apresentou os menores erros de rotação, com amplitude menor que 1,7 arcoseg, contrariamente aos eixos \"X\" e \"Y\". Constatou-se que as sintetizações de erros apresentadas podem ser empregadas como técnica de error budget, pois permitem conhecer os erros da máquina de medir por coordenadas e também rastreá-los em todo o seu volume de trabalho. / The current competitiveness of the global economy requires a sophisticated quality control in manufacturing industries, because, due to the large number of companies in this sector are constant the requirements of improvements in production. Thus, fast, accurate and flexible, systems of measurement as the CMM (Coordinate Measuring Machine) are introduced at production process and, with respect to dimensional inspection, this provides the qualities intended. Like all machines, the CMM is susceptible to errors, resulting in erroneous values of their reading response. In this context, the main objective of the study is to describe a methodology of error budget in a CMM, equating and quantifying in their preferred directions the errors incidents during a measurement procedure. The error budget was held in a moving bridge CMM in the forms, theoretical and experimental. The methodology applied in the theoretical form was developed by the method of reduced synthesizing technique of errors and the method of synthesizing technique of errors. For these synths were developed mathematical models of the machine by way of an analysis of its structure and also using the homogeneous transformations. The experimental synthesizing technique of errors was made with obtaining the individual values of 21 errors. For this method, was used a laser measurement, optical set of measurement by interferometry, electronic probe, electronic level, granite square, and fixation devices. Through the values obtained in the experimental synthesizing technique enabled to know the influence of errors on the tip of the probe. The results showed that the \"Z\" axis had the lowest errors of rotation, with amplitude less than 1.7 arcoseg, contrary to the axis \"X\" and \"Y\". It was verified that the methods of synthesizing technique of errors can be used as error budget, because they provide to know the errors of a coordinate measuring machine and also trace them throughout their volume.
20

Medição do tipo passa-não passa em máquina de medir a três coordenadas / Go-not-go gauge type inspection using a CMM (Computer Measuring Machine)

Flores, Fabricio Jesus 09 November 2001 (has links)
A fabricação de produtos cada vez melhores é fator imperativo, pois sob o ponto de vista dos fabricantes, maior fatia do mercado, maiores lucros, e para o consumidor produtos de melhor desempenho, maior vida útil, maior compacticidade, ou seja, qualidade. Por sua vez, garantir esta qualidade exige uma definição adequada das características do produto, obrigando o mundo tecnológico a investir na procura por melhores meios de controle dimensional. A tendência pelo aumento da qualidade dos produtos faz surgir a necessidade de se construir ou aperfeiçoar sistemas de medição que possam avaliar com grande rapidez e acuracidade as mais diversas características dimensionais. O objetivo deste trabalho é implementar um sistema informatizado que permita simular calibradores do tipo Passa-Não Passa em uma Máquina de Medir a Três Coordenadas (MM3C) do tipo Ponte Móvel. Cabe destacar que a grande vantagem do sistema proposto consiste na flexibilidade que se tem nas mudanças das características geométricas de cada calibrador. Com pequenas alterações no programa computacional pode-se modificar tolerâncias, diâmetros e qualidades de inspeção. Para tanto, o sistema deve possuir uma base de dados com informações da peça a ser avaliada. Com o auxílio destas informações, o sistema pode orientar o operador sobre os procedimentos a serem tomados durante o processo de inspeção. / The manufacturing of better products is an imperative factor, as it results, from the manufacturers point of view, in larger market share, high profit and, for the consumers, better performance and long life products, which means quality. On the other hand, providing quality demands a suitable definition of the product features, pushing the technology world into a search for better means of dimensional control. The tendency of increasing product quality raises the necessity of constructing or improving measurement systems which are able to evaluate a wide variety of dimensional characteristics with high accuracy and velocity. The aim of this work is to accomplish a computer system that simulates go-not-go gauges on a moving bridge coordinate measuring machine. The great advantage of the proposed system consists in the flexibility available to adapt into each gauge different geometric features. With small modifications in the computational program, tolerances, diameters and ISO tolerance can be altered. In order to perform these modifications, the system must hold a database regarding the article to be evaluated. With this information, the system can guide the operator about the procedure to be followed during the inspection process.

Page generated in 0.0365 seconds