• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 15
  • 4
  • 2
  • Tagged with
  • 52
  • 52
  • 16
  • 14
  • 13
  • 11
  • 11
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Tratamento de efluente de curtume por biofiltro aerado Submerso pré-tratado com microfiltro de membrana

Bahia, Adilson Silva [UNESP] 11 March 2014 (has links) (PDF)
Made available in DSpace on 2014-12-02T11:16:57Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-11Bitstream added on 2014-12-02T11:20:49Z : No. of bitstreams: 1 000797267.pdf: 1871218 bytes, checksum: 71b27655313be97d91cb308d5fbe6ed7 (MD5) / Os efluentes do processo de industrialização do couro em curtumes apresentam, além de elevadas concentrações de matéria orgânica em termos de Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO), altas concentrações de sólidos totais, suspensos e sulfeto, o que torna o tratamento destes efluentes problemático. O objetivo do presente trabalho foi avaliar a biotratabilidade dos efluentes de curtumes por meio do tratamento por Biofiltro Aaerado Submerso (BF) após pré-tratamento por membrana de microfiltração. Os resultados mostraram que pode haver a viabilidade técnica no uso de BF para remoção de matéria orgânica e sulfeto de águas residuárias industriais de curtume, pois atingiram, respectivamente, a remoção 84% e 98 % / The effluents from leather tanning process have in addition to high concentrations of organic matter in terms of Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD), high concentrations of total solids, total suspended solids and sulfide, which makes problematic the treatment of these effluents. The objective of this study was to evaluate the biotreatability of tannery effluent by submerged aerated biofilter after microfiltration membrane pretreatment. The results showed that can be used in the technical feasibility of BF removal of organic sulphide and industrial raw tannery wastewater as it amounted, respectively, removal to 84% and 98%
32

Caracterização de membranas de poliamida 66 preparadas pelo método de inversão de fases

Poletto, Patrícia 29 April 2010 (has links)
Neste trabalho foram preparadas membranas de poliamida 66 (PA 66) pelo método de inversão de fases (IF) e caracterizadas com o objetivo de verificar sua possível aplicação em processos de separação. As membranas de PA 66 foram preparadas utilizando dois solventes diferentes, ácido fórmico (AF) e ácido clorídrico (HCl) e água como não-solvente. As membranas preparadas na forma de filmes (não suportadas) foram caracterizadas por Espectroscopia de Infravermelho com Transformada de Fourier (FT-IR) e calorimetria exploratória diferencial (DSC), onde os resultados mostraram que a estrutura química e o comportamento térmico da PA 66 não foram alterados como o uso de ácidos como solventes. Os filmes apresentaram estrutura assimétrica, com formação de camada densa na parte superior seguida de subestrutura de poros esféricos observada por microscopia eletrônica de varredura (MEV). A espessura de camada densa variou de 10 à 25 μm, para o filme preparado em AF e HCl, respectivamente. O aumento da espessura da camada densa, ou seja, a redução de espaços vazios influenciou diretamente os resultados de percentual de água absorvida e porosidade total. A porosidade foi de 15 contra 50% para os filmes preparados em AF e HCl, respectivamente. O fluxo de vapor de água foi menor para os filmes com maior espessura de camada densa, devido ao aumento da resistência ao transporte de massa. Com o objetivo de aumentar a resistência mecânica dos filmes de poliamida, foram preparadas membranas suportadas em tecido de poliéster para posterior aplicação em processos de separação que utilizam altas pressões. As membranas suportadas foram caracterizadas pelas técnicas de BET para determinação de tamanho médio de poros, ensaios de osmose inversa (OI) e ultrafiltração (UF). Ambas as membranas preparadas em AF e HCl apresentaram valores de tamanho de poro muito próximos quando analisado por BET. O ensaio de compactação com água pura realizado a 40 bar de pressão revelou que as membranas preparadas em AF sofrem maior compactação na sua estrutura apresentando fluxo de permeado em torno de 22 Lm-2h-1 enquanto a membrana preparada em HCl apresentou fluxo de 312 Lm-2h-1. No ensaio de OI, a rejeição máxima ao cloreto de sódio foi de 7% e 4% para a membrana AF-3 e HCl-3, respectivamente. Nos ensaios de ultrafiltração (UF), realizados a 15 bar, ambas as membranas apresentaram valores de rejeição próximos a 70% para albumina de ovo e 80% para albumina bovina. Com esse resultado, podemos concluir que ambas as membranas apresentaram características de tamanho de poro e rejeição para aplicações em processos de UF. / Submitted by Marcelo Teixeira (mvteixeira@ucs.br) on 2014-06-04T16:11:59Z No. of bitstreams: 1 Dissertacao Patricia Poletto.pdf: 15767648 bytes, checksum: 81ddada763fec9ceadc8f928e56747a6 (MD5) / Made available in DSpace on 2014-06-04T16:11:59Z (GMT). No. of bitstreams: 1 Dissertacao Patricia Poletto.pdf: 15767648 bytes, checksum: 81ddada763fec9ceadc8f928e56747a6 (MD5) / In the present study, polyamide 66 (PA 66) membranes were prepared by phase inversion (PI) and characterized in order to verify their potential application in separation processes. PA 66 membranes were prepared using two different solvents, formic acid (FA) and chloridric acid (HCl), and water as a non-solvent. Membranes prepared in film form (not supported) were characterized by Fourier-transform infrared spectroscopy (FT-IR) and differential scanning calorimetry (DSC) and the results showed that the chemical structure and thermal behavior of the PA 66 were not altered by the use of acids as solvents. The films revealed an asymmetric structure with a dense top layer and a porous sublayer featuring spherical pores observed by scanning electron microscopy (SEM). The thickness of the dense layer varied from 10 to 25 μm in films prepared with FA and HCl, respectively. The increase in thickness of the dense layer, i.e., the reduction of empty spaces, directly influenced the results regarding water absorption percentage and total porosity. The porosity found was 15% and 50% for films prepared with FA and HCl, respectively. Water vapor flux was lower in films with a thicker dense layer as a result of a greater resistance to mass transfer. In order to increase mechanical resistance in polyamide films, supported membranes with polyester fabric were prepared for latter application in separation processes through high pressure. Supported membranes were characterized by BET techniques for the determination of pore size, reverse osmosis and ultrafiltration assays. Both membranes prepared with FA and HCl showed very similar pore sizes when analyzed by/with BET. A compression assay with pure water performed at a pressure of 40 bar revealed that membranes prepared with FA undergo greater compaction of its structure and had a permeate flux value of approximately 22 Lm-2h-1 whereas the membrane prepared with HCl had a permeate flux value of 312 Lm-2h-1. On reverse osmosis assays, the maximum rejection to sodium chloride was 7% and 4% for FA-3 and HCl-3 membranes, respectively. On ultrafiltration assays, performed at 15 bar, both membranes had rejection values close to 70% for egg albumin and 80% for bovine albumin. Based on this result, it is possible to conclude that both membranes revealed pore size and rejection characteristics for application in ultrafiltration processes.
33

Preparação e caracterização de membranas impregnadas com nanopartículas de prata e cobre e sua aplicação na desinfecção da água

Biron, Dionisio da Silva 24 February 2016 (has links)
Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2016-06-21T16:37:36Z No. of bitstreams: 1 Dissertacao Dionisio da Silva Biron.pdf: 4968193 bytes, checksum: b3110cb668f93c8ff3069f7d944b6668 (MD5) / Made available in DSpace on 2016-06-21T16:37:36Z (GMT). No. of bitstreams: 1 Dissertacao Dionisio da Silva Biron.pdf: 4968193 bytes, checksum: b3110cb668f93c8ff3069f7d944b6668 (MD5) Previous issue date: 2016-06-21 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES
34

Tratamento de efluente de curtume por biofiltro aerado Submerso pré-tratado com microfiltro de membrana /

Bahia, Adilson Silva. January 2014 (has links)
Orientador: Tsunao Matsumoto / Banca: Liliane Lazzari Albertin / Banca: Luis Fernando Rossi Léo / Resumo: Os efluentes do processo de industrialização do couro em curtumes apresentam, além de elevadas concentrações de matéria orgânica em termos de Demanda Química de Oxigênio (DQO) e Demanda Bioquímica de Oxigênio (DBO), altas concentrações de sólidos totais, suspensos e sulfeto, o que torna o tratamento destes efluentes problemático. O objetivo do presente trabalho foi avaliar a biotratabilidade dos efluentes de curtumes por meio do tratamento por Biofiltro Aaerado Submerso (BF) após pré-tratamento por membrana de microfiltração. Os resultados mostraram que pode haver a viabilidade técnica no uso de BF para remoção de matéria orgânica e sulfeto de águas residuárias industriais de curtume, pois atingiram, respectivamente, a remoção 84% e 98 % / Abstract: The effluents from leather tanning process have in addition to high concentrations of organic matter in terms of Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD), high concentrations of total solids, total suspended solids and sulfide, which makes problematic the treatment of these effluents. The objective of this study was to evaluate the biotreatability of tannery effluent by submerged aerated biofilter after microfiltration membrane pretreatment. The results showed that can be used in the technical feasibility of BF removal of organic sulphide and industrial raw tannery wastewater as it amounted, respectively, removal to 84% and 98% / Mestre
35

Preparação e caracterização de membranas impregnadas com nanopartículas de prata e cobre e sua aplicação na desinfecção da água

Biron, Dionisio da Silva 24 February 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES
36

Caracterização de membranas de poliamida 66 preparadas pelo método de inversão de fases

Poletto, Patrícia 29 April 2010 (has links)
Neste trabalho foram preparadas membranas de poliamida 66 (PA 66) pelo método de inversão de fases (IF) e caracterizadas com o objetivo de verificar sua possível aplicação em processos de separação. As membranas de PA 66 foram preparadas utilizando dois solventes diferentes, ácido fórmico (AF) e ácido clorídrico (HCl) e água como não-solvente. As membranas preparadas na forma de filmes (não suportadas) foram caracterizadas por Espectroscopia de Infravermelho com Transformada de Fourier (FT-IR) e calorimetria exploratória diferencial (DSC), onde os resultados mostraram que a estrutura química e o comportamento térmico da PA 66 não foram alterados como o uso de ácidos como solventes. Os filmes apresentaram estrutura assimétrica, com formação de camada densa na parte superior seguida de subestrutura de poros esféricos observada por microscopia eletrônica de varredura (MEV). A espessura de camada densa variou de 10 à 25 μm, para o filme preparado em AF e HCl, respectivamente. O aumento da espessura da camada densa, ou seja, a redução de espaços vazios influenciou diretamente os resultados de percentual de água absorvida e porosidade total. A porosidade foi de 15 contra 50% para os filmes preparados em AF e HCl, respectivamente. O fluxo de vapor de água foi menor para os filmes com maior espessura de camada densa, devido ao aumento da resistência ao transporte de massa. Com o objetivo de aumentar a resistência mecânica dos filmes de poliamida, foram preparadas membranas suportadas em tecido de poliéster para posterior aplicação em processos de separação que utilizam altas pressões. As membranas suportadas foram caracterizadas pelas técnicas de BET para determinação de tamanho médio de poros, ensaios de osmose inversa (OI) e ultrafiltração (UF). Ambas as membranas preparadas em AF e HCl apresentaram valores de tamanho de poro muito próximos quando analisado por BET. O ensaio de compactação com água pura realizado a 40 bar de pressão revelou que as membranas preparadas em AF sofrem maior compactação na sua estrutura apresentando fluxo de permeado em torno de 22 Lm-2h-1 enquanto a membrana preparada em HCl apresentou fluxo de 312 Lm-2h-1. No ensaio de OI, a rejeição máxima ao cloreto de sódio foi de 7% e 4% para a membrana AF-3 e HCl-3, respectivamente. Nos ensaios de ultrafiltração (UF), realizados a 15 bar, ambas as membranas apresentaram valores de rejeição próximos a 70% para albumina de ovo e 80% para albumina bovina. Com esse resultado, podemos concluir que ambas as membranas apresentaram características de tamanho de poro e rejeição para aplicações em processos de UF. / In the present study, polyamide 66 (PA 66) membranes were prepared by phase inversion (PI) and characterized in order to verify their potential application in separation processes. PA 66 membranes were prepared using two different solvents, formic acid (FA) and chloridric acid (HCl), and water as a non-solvent. Membranes prepared in film form (not supported) were characterized by Fourier-transform infrared spectroscopy (FT-IR) and differential scanning calorimetry (DSC) and the results showed that the chemical structure and thermal behavior of the PA 66 were not altered by the use of acids as solvents. The films revealed an asymmetric structure with a dense top layer and a porous sublayer featuring spherical pores observed by scanning electron microscopy (SEM). The thickness of the dense layer varied from 10 to 25 μm in films prepared with FA and HCl, respectively. The increase in thickness of the dense layer, i.e., the reduction of empty spaces, directly influenced the results regarding water absorption percentage and total porosity. The porosity found was 15% and 50% for films prepared with FA and HCl, respectively. Water vapor flux was lower in films with a thicker dense layer as a result of a greater resistance to mass transfer. In order to increase mechanical resistance in polyamide films, supported membranes with polyester fabric were prepared for latter application in separation processes through high pressure. Supported membranes were characterized by BET techniques for the determination of pore size, reverse osmosis and ultrafiltration assays. Both membranes prepared with FA and HCl showed very similar pore sizes when analyzed by/with BET. A compression assay with pure water performed at a pressure of 40 bar revealed that membranes prepared with FA undergo greater compaction of its structure and had a permeate flux value of approximately 22 Lm-2h-1 whereas the membrane prepared with HCl had a permeate flux value of 312 Lm-2h-1. On reverse osmosis assays, the maximum rejection to sodium chloride was 7% and 4% for FA-3 and HCl-3 membranes, respectively. On ultrafiltration assays, performed at 15 bar, both membranes had rejection values close to 70% for egg albumin and 80% for bovine albumin. Based on this result, it is possible to conclude that both membranes revealed pore size and rejection characteristics for application in ultrafiltration processes.
37

Formação de biofilmes microbianos em membranas poliméricas de poliamida e polietersulfona e seu controle por agentes sanitizantes. / Microbial biofilms formation in polymeric membranes of polyamide and polyethersulfone and its control by sanitizers agents

Camargo, Liliane Rodrigues, 1981- 19 August 2018 (has links)
Orientadores: Arnaldo Yosteruy Kuaye, Luiz Antonio Viotto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-19T05:42:17Z (GMT). No. of bitstreams: 1 Camargo_LilianeRodrigues_M.pdf: 1091941 bytes, checksum: 60be1838dcd0800329468f3b7825e521 (MD5) Previous issue date: 2011 / Resumo: O grande consumo de águas minerais tem alavancado muitos estudos de relação caracterização microbiológica, nas mais diversas regiões brasileiras. Trabalhos revelam que a grande maioria das águas brasileiras envasadas e águas de poços artesianos possuem contaminação microbiana, causando grande preocupação com relação à qualidade da água a ser consumida. Dentre os processos para tratamento da água mineral, a fim de atender as exigências comerciais e de legislações, está a microfiltração. O processo consiste da utilização de filtros de membranas poliméricas, nos quais os microrganismos ficam retidos (barreira mecânica). De acordo com a Resolução RDC nº 275/2005 Agência Nacional de Vigilância Sanitária (ANVISA), os microrganismos Escherichia coli e Pseudomonas aeruginosa, estão inseridos, juntamente com outras bactérias, como Enterococos, Clostridium perfringens e coliformes totais no quadro de controle microbiano de águas minerais. Devido à utilização dos filtros de membrana para controle destes microrganismos, há a necessidade da realização da sanitização desses filtros para evitar proliferação de microrganismos na superfície; prevenindo o entupimento dos poros da membrana e contaminação do processo. O sanitizante a base de ácido peracético e água quente são os principais agentes sanitizantes utilizados na indústria de água mineral para sanitização de equipamentos. Assim este trabalho objetivou avaliar a formação de biofilme microbiano de Escherichia coli e Pseudomonas aeruginosa em membranas poliméricas de poliamida e polietersulfona e a eficiência da sanitização das membranas por solução de ácido peracético a 0,1%, 0,2% e água quente a 85 ºC em dois diferentes tempos de contato, 10 minutos e 20 minutos. O teste foi realizado através do contato de cupons de 1 cm2 das membranas com o inóculo na concentração de 104 UFC/ mL, em temperaturas de 5, 25 e 35ºC e a análise dos cupons após 24h, 48h e 72h de contato. A quantidade de células aderidas de Escherichia coli para ambas as membranas foi de 4 log UFC/ cm2 para as primeiras 24h de contato, chegando até 6 log UFC/cm2 após 72h de contato para a temperatura de 35ºC. Para Pseudomonas aeruginosa, o comportamento de adesão foi similar, onde a maior quantidade chegou à 6,25 log UFC/cm2 após 72h de contato para a temperatura de 25ºC. Para avaliar a eficiência dos agentes sanitizantes, os cupons foram submetidos ao processo de adesão dos microrganismos e após 24 horas de contato na temperatura de 35ºC foram colocados em contato com a solução sanitizante à base de ácido peracético 0,1%, 0,2% e água quente à 85ºC durante 10 e 20 minutos. Os sanitizantes utilizados ofereceram grande eficiência na redução das bactérias aderidas nas membranas. A concentração do sanitizante químico mais efetivo foi 0,2% para 10 e 20 minutos de contato, onde cerca de 80% dos cupons tiveram redução de > 4 Log UFC/cm2. A água na temperatura de 85ºC em ambos os tempos de contato (10 minutos e 20 minutos) também ofereceu grande eficiência na redução logarítmica dos microrganismos, onde 100% dos cupons apresentaram redução > 4 Log UFC/cm2 / Abstract: The high consumption of mineral water has leveraged many studies regarding microbiological, in several brazilian regions. Papers reveal that the vast majority of brazilian bottled waters and water from artesian wells have microbiological contamination, causing great concern about the quality of water being consumed. Among the processes for treatment of mineral water in order to meet business requirements and laws is microfiltration. The process consist in the use of polymer membrane filters, the where the microorganisms are withheld (mechanical barrier). According to Resolution RDC 275/2005 of National Agency for Sanitary Vigilance (ANVISA) microorganisms Escherichia coli and Pseudomonas aeruginosa, are inserted, along with other bacteria such as Enterococcus, Clostridium perfringens and total coliforms under control of microbiological characteristics of mineral waters. Due to the use of membrane filters to control these microorganisms, there is the need to perform sanitization filters to prevent the proliferation of microorganisms on the surface, preventing the clogging of the pores of the membrane and process contamination. The sanitizing the basis of peracetic acid and hot water are the main agents sanitizers available in the industry of mineral water to equipments sanitize. This study aimed to evaluate the microbial biofilm formation of Escherichia coli and Pseudomonas aeruginosa in polymeric membranes of polyamide and polyethersulfone membranes and the sanitizing ef ficiencyprocess with of peracetic acid 0.1%, 0.2% and hot water at 85 °C in two different contact times, 10 minutes and 20 minutes. The test was conducted through the contact of coupons with 1 cm2 of the membranes in the inoculum with concentration of 104 CFU /mL, at temperatures of 5, 25 and 35 °C and an alysis of the coupons after 24h, 48h and 72h of contact. The amount of Escherichia coli cells attached to both membranes was 4 log CFU /cm2 for the first 24 hours of contact, reaching 6 log CFU /cm2 after 72 hours of contact to a temperature of 35 °C. For Pseudomonas aeruginosa, the adherence behavior was similar, where the largest amount reached 6.25 log CFU /cm2 after contact for 72 hours at 25 º C. To evaluate the effectiveness of sanitizing agents, the coupons were subjected to the adhesion of microorganisms and after 24 hours of contact at 35 ºC were placed in contact with the sanitizing solution based on peracetic acid 0.1%, 0.2% and hot water at 85 °C for 10 to 20 minutes. The sanitizers used offered high efficiency in reducing bacteria attached on the membranes. The concentration of chemical sanitizer most effective was 0.2% for 10 and 20 minutes of contact, where about 80% of the coupons was reduced by > 4 Log CFU/cm2. The water temperature at 85 °C in both contact times (10 and 20 minutes) also offered greater efficiency in logarithmic reduction of microorganisms, where 100% of the coupons showed a reduction > 4 Log UFC/cm2 / Mestrado / Mestre em Tecnologia de Alimentos
38

Identificação e enumeração rapidas de Escherichia coli e Salmonella typhimurium no ovo de galinha atraves da tecnica da membrana filtrante / Identification and rapid enumeration of Escherichia coli and Salmonella typhimurium in chicken eggs by the technique of filtering membrane

Leite, Clarice Queico Fujimura 08 June 1984 (has links)
Orientador : Fumio Yokoya / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos e Agricola / Made available in DSpace on 2018-07-20T00:41:04Z (GMT). No. of bitstreams: 1 Leite_ClariceQueicoFujimura_D.pdf: 3804903 bytes, checksum: d606b7f70d7b2f4627cf89586684ed12 (MD5) Previous issue date: 1984 / Resumo: Dentro da linha de pesquisa de identificação e enumeração rápida de microrganismos, o presente trabaiho foi realizado no sentido de verificar a viabilidade do emprego da membrana filtrante na recuperação de Escherichia cali e Salmanella trphimurium, inoculadas experimentalmente em ovo de galinha (clara, gema e ovo liquido). Após ó tratamento com a protease bacteriana "Alcalase", viabilizou-se a filtragem de 5,0 g de clara, 2,5 g de ovo liquido e l,O g de gema, através da membrana HAWG 47 mm da marca Millipore. A recuperaçao de E..ca}i em clara foi realizada através do emprego siImultâneo da técnica de plaqueamento em profundidade e de um método por nós desenvolvido, utilizando a membrana filtrante. Os resultados obtidos com a técnica do plaqueamento foram próximos aos conseguidos com a técnica proposta. Colocando os dois resultados em gráfico, foi obtida uma reta de regressão com coeficiente de correlação de 0;95 e coeficiente angular de 0,99. Os resultados da experiência de inoculação de ovo liquido com E. cali, obtidos com o emprego das duas técnicas, forneceram uma reta com coeficiente de correlação de 0,98. O coeficiente angular"foi baixo, 0,39 .havendo necessidade da introdução de um fator de correção multiplicativo de 2,6, para compensar a menor recuperação obtida com o uso da técnica da membrana filtrante. O isolamento de E. coli da gema foi insatisfatório, com o emprego da técnica da membrana filtrante. A S. typhimurium, previamente .inoculada em clara e em ovo liquido, foi recuperada como emprego da técnica clássica de enriquecimento e isolamento em meios seletivos e com o método por nós desenvolvido. Os resultados demonstraram que mesmo em concentrações tão baixas como 0,3 microrganismo por grama de clara, é possivel recuperar a s. typhimurium através da técnica da membrana filtrante. A recuperação deste microrganismo do ovo liquido foi insatisfatória / Abstract: In the line of research for the identification and rapid enumeration of micro-organisms, the present work was carried out with the object of verifying the viabili ty of the use of a membrane filter in the recuperation of Escherichia coli and Salmonella typhimurium, inoculated experimentally into the hen'g egg (white, yolk, and whole liquid egg). After treatment wi th bacterian protease "Alcala se", 5.0 g of egg white, 2.5 g of whole liquid egg, and 1,0 g of egg yolk were filtered through the 47 mm HAWG filter (Millipore). The recuperation of E. coli from the egg white was done by means of the simultaneous use of pour plate method and a method developed by us, using a membrane filter. The results obtained using the pour plate technique were very similar to those developed by the authors of this research. When both results were plotted on a graph, a line of regression with a correlation coefficient of 0,95 and an angular coefficient of 0,99 was obtained. The results of the experiment involving the inoculationof the whole liquid egg with E. coli, using both techniques, showed a line with a correlation coeficient of 0.98. The angular coefficient of 0.39 was low, making the introduction of a manipulative correction factor of 2,6 necessary in order to compensate for a lesser recuperation obtained using the membrane filter technique. The isolation of E. coli from the yolk was not satisfactory using the membrane filter technique. The S.typhimurium, previously inoculated into the white and whole liquid egg, was recuperated us1ng the classic technique of enrichment and isolation in selective media and als,oby methods developed by USe The results show that even in concentrations as low as 0.3 micro-organisms per gram of egg white, it is possible to recuperate the S. typhimurium by use of the membrane filter technique. The recuperation of this microorganism from the who1e 1iquid egg was insatisfactory / Doutorado / Ciência de Alimentos / Doutor em Ciência de Alimentos
39

An evaluation of a modified membrane filter technique for the recovery of fecal coliforms exposed to selected heavy metals

Gayle, Benjamin P. 28 July 2010 (has links)
A bench study was conducted to compare two membrane filter techniques for their efficiency in recovering fecal coliforms exposed to selected heavy metals. The effects on recovery by increasing time and metal concentration were also examined. The recovery methods employed included the standard membrane filter technique (S-MF) and a modified membrane filter technique (M-MF)~ which consisted of a lactose agar overlay and a five-hour preincubation at 35 C. The heavy metals Cd, Cr, Pb, and Zn were examined, each at two concentrations, to evaluate their effect on the recovery of the I. coli test organism, after exposure for 6, 24, and 48 hours. A statistical analysis of the data found the recoveries obtained by the M-MF to be significantly greater (.0001 level) than those of the S-MF, in all cases. Time was also found to significantly effect recovery, with recoveries decreasing as time increased. A significant difference was also found between the effects of the heavy metals tested and the concentrations of metals was likewise found to significantly effect recovery, with decreased recoveries being obtained at the high concentration of each metal. / Master of Science
40

An evaluation of a modified membrane filter procedure for enumerating stressed fecal coliforms in chlorinated sewage effluents

Clark, Steven Paul January 1977 (has links)
Wastewater samples were collected from both the secondary settling and the chlorine contact tanks at a secondary sewage treatment plant (trickling filter) in Blacksburg, Virginia and analyzed for fecal coliforms using three procedures. Physical parameters including total suspended solids, DO, pH, turbidity, temperature and total chlorine residual were measured in effort to ascertain their effect on fecal coliform recoveries. The three procedures employed included the multiple-tube fermentation technique that yields the most probable number (MPN), the standard MF technique (SF-MF), and a modified MF technique (IF-MF) which consisted of a lactose overlay and a 5-hour incubation period at 44.5°C. A statistical analysis of the data showed that the means of the recoveries by the IF-MF technique were significantly greater (0.01 level) than those by the SF-MF technique in both the secondary settling tank and the chlorine contact tank samples. Recoveries by the IF-MF technique were comparable to those by the MPN technique when samples from the secondary settling basin were analyzed, but not in samples from the chlorine contact tank. However, the means of the IF-MF recovery procedure were within the 95 percent confidence interval associated with the MPN. No relationships could be established between the observed variations in the physical and chemical characteristics of the treated sewage samples and the fecal coliform densities. / Master of Science

Page generated in 0.0881 seconds