• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A Comparison of Microlab Discussions of Interpersonal Competencies and Corrective Feedback on Counselor Trainees' Defensiveness Levels

Dean, Christian 21 May 2005 (has links)
This study explored the comparison of microlab discussions of interpersonal competencies and corrective feedback on counselor trainees' defensiveness levels. Additionally, the effects of microlab discussions of interpersonal competencies or corrective feedback on counselor trainees' beliefs about their ability to communicate more clearly, receive corrective feedback with less difficulty, and act on corrective feedback receive more easily were explored. Participants in this study (N = 72) were counselor trainees enrolled in three different universities within the New Orleans metropolitan area. Participants completed the Tennessee Self-Concept Scale: Second Edition (TSCS: 2; Fitts & Warren, 1996) at least three weeks before taking part in a microlab discussion of interpersonal competencies or corrective feedback or not taking part in any discussion. Upon completion of the microlab discussion, participants in the treatment conditions completed the TSCS: 2 for the second time. Participants in the control condition simply met and completed the second administration of the TSCS: 2. Analyses of covariance were conducted on the posttest scores using the pretest as a covariate. Also, interaction effects were explored between demographic characteristics and treatment condition on posttest scores as well as responses to a group evaluation. Results did not support any of the hypotheses associated with participants who engaged in microlab discussion would have a lower defensiveness score as compared to a control group. Promising findings resulted from reactions to both microlabs by participants regarding their beliefs about their abilities to communicate more clearly, receive corrective feedback with less difficulty, and act on corrective feedback received more easily in the future. Also, a pattern associated with the number of courses completed was indicated due to a significant correlation with change in defensiveness course and interaction effects with treatment condition on responses to question 1 and 3 of the group evaluation. Counselor education programs, counselors who work with groups, and counselor trainees may benefit from exploring the possible benefits associated with microlab discussions as a form of pregroup training. Future research may provide more insight into the development of an instrument to more effectively measure defensiveness within the context of receiving corrective feedback. Also, the development of multi-session pregroup training may prove to be more effective in reducing defensiveness levels.
2

Microlaboratórios autônomos para monitoramento de parâmetros de qualidade da água. / Autonomous microlaboratories for water quality monitoring parameters.

Rocha, Zaira Mendes da 10 November 2009 (has links)
Neste trabalho, foram desenvolvidos MicroLaboratórios Autônomos (MLA), baseados no conceito de MicrosSistemas de Análise Total (TAS), que permitem a integração das etapas associadas ao método analítico em único dispositivo. Os MLA foram fabricados utilizando a tecnologia LTCC (Low Temperature Co-fired Ceramics), que permitiu um alto grau de integração das plataformas químicas microfluídica e eletrônica, utilizando o mesmo substrato. O MLA amperométrico foi construído de forma a integrar canais, misturadores e eletrodos (auxiliar, de referência e de trabalho (sendo o último facilmente removível, tornando o dispositivo mais versátil)). Também, possui integrado em sua superfície um potenciostato, capaz de aplicar potenciais constantes e registrar com precisão correntes na faixa de nA a A. Com o equipamento, foram realizadas medições de cianeto de ferro e cloro livre confirmando a funcionalidade do MLA amperométrico. Para tal, foram testadas concentrações de K4Fe(CN)6 variando de 0,1 3 mM, apresentando faixa linear de 0,1 a 0,75 mM com coeficiente de correlação linear de 0,997 e RSD de 1,91 % (calculado para a amostra de 0,75 mM, n = 13). Cloro livre foi medido na faixa de 0,35 7,10 mM apresentando resposta linear com r2 = 0,998, o RSD obtido foi de 1,93 % (3,5 mM; n = 15). O cloro livre foi medido em amostra reais de piscinas na faixa 0,4 a 1,1 mg L-1 e os resultados foram comparados com o método DPD (Ndietil- p-fenilenodiamina) apresentando resultados similares com r2 = 0,91. O MLA fotométrico segue o mesmo princípio do amperométrico com canais, misturadores, célula de fluxo, detector, arranjo de LEDs (420, 480, 515, 565, 590, 630 e 700 nm) e eletrônica de controle integrados no mesmo substrato. O equipamento foi desenvolvido permitindo dois modos de operação: espectrofotômetro e fotômetro. No modo espectrofotométrico foi empregado na determinação qualitativa e quantitativa de diversos corantes (alaranjado de metila, azul de metileno, verde de bromocressol e vermelho de fenol). Já na opção fotométrico foi usado na determinação de fósforo reativo em águas, por meio de um sistema completamente automatizado. Neste caso, o controle de diversas válvulas e uma bomba peristáltica permitiu a implementação de procedimentos de automatização como: multicomutação, amostragem binária e parada de fluxo (stopped flow. A utilização deste sistema automatizado permitiu a comparação entre dois métodos de preparações de amostra: diluição on-line (utilizando as válvulas) e preparadas manualmente. Para ambos os casos foram analisadas duas faixas de concentrações (0,1 a 1 mg L-1 e 1,5 a 15 mg L-1). A primeira faixa apresentou-se linear para ambos os métodos de preparação de amostra, apresentando limites de detecção para fósforo reativo de 15,8 g L-1 e 14,9 g L-1. Por outro lado, foi observado que a segunda faixa de concentração não obedece à lei de Beer. Na segunda faixa, a curva analítica foi linear no intervalo de concentração de 1,5 a 7,5 mg L-1 de fósforo reativo com r2 = 0,965 e RSD de 0,43 % (7,5 mg L-1, n = 3). A frequência de medições analíticas foi de 30 determinações por hora, o que indica que a plataforma proposta pode ser utilizada em monitoramente contínuo e de tempo real. / Analysis System (uTAS) concept which allows the integration of all steps related to an analytical process in a single device. The developed MLAs were used to monitor water quality. The MLAs were fabricated using the LTCC (Low Temperature Co-fired Ceramics) technology which allows a high integration level between chemical, microfluidics and electronics platforms on the same substrate. The amperometric MLA was build in order to integrate channels, mixers and electrodes (reference, auxiliary and work) being the last one easily removable making the device even more versatile. It also has, integrated on its surface, a potentiostate capable of applying constant voltages and precisely recording currents in the range from nA to A. With this equipment, measurements were conducted for free chlorine and iron, confirming the functionality of the amperometric MLA. Concentrations from 0,1 to 3 mM of K4Fe(CN)6 were evaluated obtaining a linear range from 0,1 to 0,75 mM with a linear correlation coefficient of 0,997 and a RSD of 1,91 % (calculated for the 0,75 mM sample with n = 13). Free chlorine was evaluated in the range from 0,35 to 7,10 mM obtaining a linear response with a r2 = 0,998, the obtained RSD was 1,93 % (for 3,5 mM; n = 15). Free chlorine was also evaluated in real samples from swimming pools in the range from 0,4 to 1,1 mg·L-1, comparing the results with those obtained by the colorimetric DPD method, showing similar values with a r2 = 0,91. The photometric MLA follows the same principle of the amperometric one, with channels, mixers, flow cell, detector, LEDs array (420, 480, 515, 565, 590, 630 e 700 nm) and control electronics, integrated in the same substrate. This equipment was developed for two operation modes: spectrophotometric and photometric. The spectrophotometric mode was used for qualitative and quantitative determination of different dyes (methyl orange, methylene blue, bromocressol green and phenol red). The photometric option was used for the determination of phosphate concentration in water, by means of a fully automated system. In this case the control of several valves and a peristaltic pump allowed the implementation or automated procedures like multicommutation, binary sampling and stopped flow. The use of this automated system allowed the comparison between two methods for sample preparation: online dilution (with valves) and manual preparation. In both cases two concentration ranges were evaluated (0,1 a 1 mg L-1 and 1,5 a 15 mg L-1). The first range linear for both sample preparation methods, with detection limits of 15,8 g L-1 e 14,9 g L-1 for orthophosphate. On the other side it was observed that in the second range of concentrations it does not obey the Beers law. In the second range, the analytics curve was linear in the interval from 1,5 to 7,5 mg L-1 of orthophosphate with a r2 = 0,965 and a RSD of 0,43 % (7,5 mg L-1, n = 3). The analytical frequency was about 30 determinations per hour, which indicates a good performance of the proposed device for on-line and real time monitoring.
3

Microlaboratórios autônomos para monitoramento de parâmetros de qualidade da água. / Autonomous microlaboratories for water quality monitoring parameters.

Zaira Mendes da Rocha 10 November 2009 (has links)
Neste trabalho, foram desenvolvidos MicroLaboratórios Autônomos (MLA), baseados no conceito de MicrosSistemas de Análise Total (TAS), que permitem a integração das etapas associadas ao método analítico em único dispositivo. Os MLA foram fabricados utilizando a tecnologia LTCC (Low Temperature Co-fired Ceramics), que permitiu um alto grau de integração das plataformas químicas microfluídica e eletrônica, utilizando o mesmo substrato. O MLA amperométrico foi construído de forma a integrar canais, misturadores e eletrodos (auxiliar, de referência e de trabalho (sendo o último facilmente removível, tornando o dispositivo mais versátil)). Também, possui integrado em sua superfície um potenciostato, capaz de aplicar potenciais constantes e registrar com precisão correntes na faixa de nA a A. Com o equipamento, foram realizadas medições de cianeto de ferro e cloro livre confirmando a funcionalidade do MLA amperométrico. Para tal, foram testadas concentrações de K4Fe(CN)6 variando de 0,1 3 mM, apresentando faixa linear de 0,1 a 0,75 mM com coeficiente de correlação linear de 0,997 e RSD de 1,91 % (calculado para a amostra de 0,75 mM, n = 13). Cloro livre foi medido na faixa de 0,35 7,10 mM apresentando resposta linear com r2 = 0,998, o RSD obtido foi de 1,93 % (3,5 mM; n = 15). O cloro livre foi medido em amostra reais de piscinas na faixa 0,4 a 1,1 mg L-1 e os resultados foram comparados com o método DPD (Ndietil- p-fenilenodiamina) apresentando resultados similares com r2 = 0,91. O MLA fotométrico segue o mesmo princípio do amperométrico com canais, misturadores, célula de fluxo, detector, arranjo de LEDs (420, 480, 515, 565, 590, 630 e 700 nm) e eletrônica de controle integrados no mesmo substrato. O equipamento foi desenvolvido permitindo dois modos de operação: espectrofotômetro e fotômetro. No modo espectrofotométrico foi empregado na determinação qualitativa e quantitativa de diversos corantes (alaranjado de metila, azul de metileno, verde de bromocressol e vermelho de fenol). Já na opção fotométrico foi usado na determinação de fósforo reativo em águas, por meio de um sistema completamente automatizado. Neste caso, o controle de diversas válvulas e uma bomba peristáltica permitiu a implementação de procedimentos de automatização como: multicomutação, amostragem binária e parada de fluxo (stopped flow. A utilização deste sistema automatizado permitiu a comparação entre dois métodos de preparações de amostra: diluição on-line (utilizando as válvulas) e preparadas manualmente. Para ambos os casos foram analisadas duas faixas de concentrações (0,1 a 1 mg L-1 e 1,5 a 15 mg L-1). A primeira faixa apresentou-se linear para ambos os métodos de preparação de amostra, apresentando limites de detecção para fósforo reativo de 15,8 g L-1 e 14,9 g L-1. Por outro lado, foi observado que a segunda faixa de concentração não obedece à lei de Beer. Na segunda faixa, a curva analítica foi linear no intervalo de concentração de 1,5 a 7,5 mg L-1 de fósforo reativo com r2 = 0,965 e RSD de 0,43 % (7,5 mg L-1, n = 3). A frequência de medições analíticas foi de 30 determinações por hora, o que indica que a plataforma proposta pode ser utilizada em monitoramente contínuo e de tempo real. / Analysis System (uTAS) concept which allows the integration of all steps related to an analytical process in a single device. The developed MLAs were used to monitor water quality. The MLAs were fabricated using the LTCC (Low Temperature Co-fired Ceramics) technology which allows a high integration level between chemical, microfluidics and electronics platforms on the same substrate. The amperometric MLA was build in order to integrate channels, mixers and electrodes (reference, auxiliary and work) being the last one easily removable making the device even more versatile. It also has, integrated on its surface, a potentiostate capable of applying constant voltages and precisely recording currents in the range from nA to A. With this equipment, measurements were conducted for free chlorine and iron, confirming the functionality of the amperometric MLA. Concentrations from 0,1 to 3 mM of K4Fe(CN)6 were evaluated obtaining a linear range from 0,1 to 0,75 mM with a linear correlation coefficient of 0,997 and a RSD of 1,91 % (calculated for the 0,75 mM sample with n = 13). Free chlorine was evaluated in the range from 0,35 to 7,10 mM obtaining a linear response with a r2 = 0,998, the obtained RSD was 1,93 % (for 3,5 mM; n = 15). Free chlorine was also evaluated in real samples from swimming pools in the range from 0,4 to 1,1 mg·L-1, comparing the results with those obtained by the colorimetric DPD method, showing similar values with a r2 = 0,91. The photometric MLA follows the same principle of the amperometric one, with channels, mixers, flow cell, detector, LEDs array (420, 480, 515, 565, 590, 630 e 700 nm) and control electronics, integrated in the same substrate. This equipment was developed for two operation modes: spectrophotometric and photometric. The spectrophotometric mode was used for qualitative and quantitative determination of different dyes (methyl orange, methylene blue, bromocressol green and phenol red). The photometric option was used for the determination of phosphate concentration in water, by means of a fully automated system. In this case the control of several valves and a peristaltic pump allowed the implementation or automated procedures like multicommutation, binary sampling and stopped flow. The use of this automated system allowed the comparison between two methods for sample preparation: online dilution (with valves) and manual preparation. In both cases two concentration ranges were evaluated (0,1 a 1 mg L-1 and 1,5 a 15 mg L-1). The first range linear for both sample preparation methods, with detection limits of 15,8 g L-1 e 14,9 g L-1 for orthophosphate. On the other side it was observed that in the second range of concentrations it does not obey the Beers law. In the second range, the analytics curve was linear in the interval from 1,5 to 7,5 mg L-1 of orthophosphate with a r2 = 0,965 and a RSD of 0,43 % (7,5 mg L-1, n = 3). The analytical frequency was about 30 determinations per hour, which indicates a good performance of the proposed device for on-line and real time monitoring.

Page generated in 0.0523 seconds