• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Využití multi-echo sekvencí pro DSC-MRI / Using multi-echo sequences in DSC-MRI

Černý, Štěpán January 2016 (has links)
The task of this thesis is to study the subject of perfusion analysis based on dynamic imaging with T2/T2* contrast. The focus was on the acquisition commonly used for DSC-MRI and especially in the acquisition pulse sequences that use images with different echo time, so called Multi-echo sequence. Principles of dynamic measurement by magnetic resonance imaging, the role of contrast agents and their influence on the relaxation times are described. It also describes the problems perfusion analysis, measurement and mathematical modeling parameters entering to the convolution dependency for getting perfusion parametersIn the experimental part is developed automatic algorithm to gain curves relaxation time T2 *. Next, the synthetic data are created and tested robustness estimate perfusion parameters against noise. In the next phase of work there are compared real scanned objects with using a conversion with T2 * and free of T2*. In the last phase of work is compared influence of length of used echo times on concentration curves and after perfusion analysis influence on resulting perfusion parameters.
2

Studies of the crystalline lens using magnetic resonance imaging

Jones, Catherine Elizabeth January 2004 (has links)
The eye lens grows continuously throughout life and changes its shape as the eye changes focus from a distant to a near object (the process of accommodation). These changes are complex because they may affect not only the shape of the lens, but also its refractive index distribution. To date there has been no satisfactory technique for directly and non-invasively measuring these changes. In this study the refractive index distribution through the isolated lens was measured non-invasively using a novel MRI technique. The dependence of the refractive index value of lens tissue on its transverse relaxation rate (R2) was determined empirically from measurements on lens homogenate samples. Using a multi-spin-echo imaging sequence, data were acquired for constructing R2 maps of a central slice through the isolated lens. These R2 maps were transformed to refractive index maps using the empirically determined dependence of refractive index on R2. Using a standard algorithm for ray tracing through gradient index media, the propagation of light rays through the index map were simulated. The optical properties of the lens, such as focal length, were then measured. The technique was validated by also directly measuring the focal length of each lens using laser ray tracing. The subtle changes in refractive index distribution that are responsible for the dramatic change in the optical properties of the isolated lens with age, were observed for the first time. The decrease in surface power of the isolated lens with age accounted only partially for the decrease in total lens power with age, the remainder resulting from a reduction in the gradient of refractive index (GRIN) power. It is likely that this reduction in GFUN power is the mechanism by which the eye maintains emmetropia (good distant vision) with age despite the increasing curvature of its surfaces. The reduction in the GRIN power of the lens was found to be mainly due to a flattening of the refractive index profile in the central region of the lens, accompanied by steepening of the profile near the edge of the lens. In agreement with a previous MRI study of the isolated human eye lens, this study found a decrease in the refractive index of the nucleus with age. However the age related change in this study was not as large and not found to be statistically significant. The results demonstrate that existing simple models for the optics of the eye lens are inadequate to accurately describe its properties. Several more sophisticated models were considered in an attempt to describe better the age-dependent changes that occur in both the power of the lens and its longitudinal aberration. Mathematical modelling was also used to simulate the accommodative process and investigate possible changes in the index distribution of the lens that may occur with accommodation. A preliminary in vivo study was performed aimed at observing the change in the refractive index distribution of the eye lens with age and accommodation. These results demonstrated the feasibility of the technique for in vivo applications and showed that within experimental error there is little change in the central refractive index of the lens with age. However the resolution achievable with standard clinical imaging sequences and signal detection hardware was not optimal for in vivo refractive index mapping of changes in the human eye lens with accommodation. Finally therefore, methods for refining the technique for in vivo applications are discussed which may make it possible to directly and simultaneously measure both the shape and refractive index distribution of the lens with age and accommodation.
3

Porovnání a optimalizace měření single-echo a multi-echo BOLD fMRI dat / Comparison and assessment of single-echo and multi-echo BOLD fMRI acquisition

Kovářová, Anežka January 2018 (has links)
This master’s thesis deals with functional magnetic resonance and monitoring of the effect of acquisition acceleration methods on the quality of functional images and observed BOLD signal. The basic principles of magnetic resonance imaging, the explanation of the specifics of functional magnetic resonance and the formation and scanning of BOLD signal are described here. Subsequently, there is the definition of fMRI experiment and description of sequences used for fMRI, focusing on aquisition acceleration techniques. The influence of sequence parameters on image quality and the data processing methods are explained aftewards. The practical part describes the parameters of used sequences, the acquisition procedure and the task for the subject during aquisition. Data from 26 healthy volunteers were obtained and analyzed afterwards. Based on this, the differencesbetween the different sequence variants were evaluated and the initial assumption that the multi-echo acquisition yields better results with faster measurements than single-echo was confirmed.
4

Advances in real-time phase-contrast flow MRI and multi-echo radial FLASH

Tan, Zhengguo 26 April 2016 (has links)
No description available.

Page generated in 0.044 seconds