• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Novel Methods for T2 Estimation Using Highly Undersampled Radial MRI Data

Huang, Chuan January 2011 (has links)
The work presented in this dissertation involves the development of parametric magnetic resonance imaging (MRI) techniques that can be used in a clinical set up. In the first chapter an introduction of basic magnetic resonance physics is given. The introduction covers the source to tissue magnetization, the origin of the detectable signal, the relaxation mechanisms, and the imaging principles. In the second chapter T₂ estimation - the main parametric MRI technique addressed in this work - is introduced and the problem associated with T₂ estimation from highly undersampled fast spin-echo (FSE) data is presented. In Chapter 3, a novel model-based algorithm with linearization by principal component analysis (REPCOM) is described. Based on simulations, physical phantom and in vivo data, the proposed algorithm is shown to produce accurate and stable T₂ estimates. In Chapter 4, the concept of indirect echoes associated with the acquisition of FSE data is introduced. Indirect echo correction using the extended phase graph approach is then studied for standard sampled data. A novel reconstruction algorithm (SERENADE) is presented for the reconstruction of decay curves with indirect echoes from highly undersampled data. The technique is evaluated using simulations, physical phantom and in vivo data; decay curves with indirect echoes are shown to be accurately recovered by this technique. Chapter 5 is dedicated to correcting the partial volume effect (PVE) in T₂ estimation. For the case of small lesions within a background tissue, PVE affects T₂ estimation which in turn affects lesion classification. A novel joint fitting algorithm is proposed and compared to conventional fitting algorithms using fully sampled spin-echo (SE) images. It is shown that the proposed algorithm is more accurate, robust, and insensitive to region of interest drawing than the conventional fitting algorithms. Because the acquisition of fully sampled SE images is long, the technique is combined with a thick refocusing slice approach in order to be able to use undersampled FSE data and reduce the acquisition time to a breath hold (~ 20 s). The final chapter summarizes the results presented in the dissertations and discusses areas for future work.
2

Development of Advanced Acquisition and Reconstruction Techniques for Real-Time Perfusion MRI

Roeloffs, Volkert Brar 16 June 2016 (has links)
Diese Doktorarbeit befasst sich mit der methodischen Entwicklung von Akquisition- und Rekonstruktionstechniken zur Anwendung von Echtzeit-Bildgebungstechniken auf das Gebiet der dynamischen kontrastmittelgestützten Magentresonanztomographie. Zur Unterdrückung unerwünschter Bildartefakte wird eine neue Spoiling-Technik vorgeschlagen, die auf randomisierten Phasen der Hochfrequenzanregung basiert. Diese Technik erlaubt eine schnelle, artefaktfreie Aufnahme von T1-gewichteten Rohdaten bei radialer Abtastung. Die Rekonstruktion quantitativer Parameterkarten aus solchen Rohdaten kann als nichtlineares, inverses Problem aufgefasst werden. In dieser Arbeit wird eine modellbasierte Rekonstruktionstechnik zur quantitativen T1-Kartierung entwickelt, die dieses inverse Problem mittels der iterativ regularisierten Gauß-Newton-Methode mit parameterspezifischer Regularisierung löst. In Simulationen sowie in-vitro- und in-vivo-Studien wird Genauigkeit und Präzision dieser neuen Methode geprüft, die ihre direkte Anwendung in in-vitro-Experimenten zur "first-pass"-Perfusion findet. In diesen Experimenten wird ein kommerziell verfügbares Phantom verwendet, dass in-vivo-Perfusion simuliert und gleichzeitig vollständige Kontrolle über die vorherrschenden Austauschraten erlaubt.
3

Advances in real-time phase-contrast flow MRI and multi-echo radial FLASH

Tan, Zhengguo 26 April 2016 (has links)
No description available.
4

Multi-Directional Phase-Contrast Flow MRI in Real Time

Kollmeier, Jost M. 31 August 2020 (has links)
No description available.

Page generated in 0.0503 seconds