21 |
Atrofia parcial em biopsias de agulha de prostata : Util no diagnostico diferencial entre carcinoma e atrofia da prostata? / Partial atrophy in needle biopsy of prostate : Is it useful in differential diagnosis between atrophy carcinoma of prostate?Worschech, Adriana 29 August 2008 (has links)
Orientador: Athanase Billis / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-11-07T16:10:17Z (GMT). No. of bitstreams: 1
Worschech_Adriana_M.pdf: 2136837 bytes, checksum: e169d43b81c649e3dde44c36f7a96278 (MD5)
Previous issue date: 2008 / Resumo: A atrofia parcial (AP) é uma lesão benigna que mais freqüentemente imita adenocarcinoma, particularmente a variante parcial. AP ocorre com maior freqüência no lobo posterior ou zona periférica e ganhou importância maior com o uso das biópsias por agulha na detecção do carcinoma prostático. A atrofia parcial e a hiperplasia pós-atrófica (atrofia hiperplásica) são as lesões benignas que mais freqüentemente são confundidas com adenocarcinoma. Uma das razões que contribuem para dificultar o diagnóstico da atrofia parcial está relacionada com a ausência de células basais em alguns ácinos. Mais recentemente a aplicação da molécula de AMACR (alfa-metilacil Co-enzima A racemase) como marcador de células neoplásicas através de imunoistoquímica tem auxiliado no diagnóstico diferencial com o adenocarcinoma. Entretanto, sua aplicação na rotina diagnóstica ainda não está estabelecida. A imunoexpressão da AMACR pode causar algumas dúvidas em sua interpretação. Na literatura existem poucos estudos que relatam a expressão da AMACR em atrofia parcial. Avaliamos através da imunoistoquímica a expressão da AMACR e do 34ßE12 (citoqueratina de alto peso molecular) através do coquetel P504S+34ßE12 em material proveniente de 74 biópsias por agulha de próstata correspondendo a 61 pacientes. Foram analisados um total de 1198 ácinos prostáticos (324 ácinos com adenocarcinoma, 213 ácinos normais, 190 ácinos com atrofia parcial, 298 ácinos com hiperplasia pós-atrófica, 139 ácinos com atrofia simples e 34 ácinos com atrofia esclerosante). Nos ácinos com adenocarcinoma a intensidade da marcação da AMACR foi forte em 251/324 (77.5%) e fraca 73/324 (22.5%). Não houveram casos negativos. Nos ácinos normais observou-se marcação para a AMACR forte em 13/213 (6.1%), fraca em 33/213 (15.5%) e negativa em 167/213 (78.4%). A atrofia parcial apresentou marcação para a AMACR fraca em 47/190 (24.7%) e negativa em 143/190 (75.3%). Não houve marcação forte em nenhum dos casos de atrofia parcial. Os ácinos normais mostraram expressão para AMACR negativo, fraco e forte onde os valores foram respectivamente 167/213 (78,4%), 33/213 (15,5%) e 13/213 (6,1%). A atrofia parcial mostrou-se negativa, e fraca para imunoexpressão da AMACR em 143/190 (75,3%) e 47/190 (24,7%) respectivamente. Não foi observada forte positividade em atrofia parcial, no entanto, a fraca positividade observada em cerca de 25% dos ácinos pode causar dificuldade para a interpretação correta no diagnóstico diferencial de câncer e atrofia parcial. A AMACR foi negativa em todos os ácinos da atrofia simples, hiperplásica (ou hiperplasia pós-atrófica) e esclerosante, por conseguinte, sem qualquer ajuda no diagnóstico diferencial de adenocar-cinoma. A distribuição das células basais, observadas na atrofia simples, hiperplásica e esclerosante foram descontínuas e as células do compartimento secretor mostraram imunoexpressão aberrante de 34ßE12 sugerindo um fenótipo intermédio.
Analisando-se os estes resultados conclui-se que o diagnóstico diferencial do adenocarcinoma com atrofia parcial deve ser feito com cautela considerando-se que a expressão da AMACR, apesar de fraca em nosso estudo, pode ocorrer em cerca de 25% dos ácinos. Soma-se a este achado o fato de que em 23.2% dos ácinos de atrofia parcial as células basais estão ausentes. Estes dados impõem cautela no difícil diagnóstico diferencial de pequenos focos "suspeitos, mas não diagnósticos de adenocarcinoma da próstata", sendo que, em alguns casos, os critérios puramente morfológicos poderão ser os únicos na identificação da lesão. / Abstract: Prostatic atrophy (PA) is the benign lesion that most frequently mimicks adenocarcinoma particularly the partial variant. PA occurs more frequently in the peripheral zone and gained greater importance with the use of needle biopsies in detecting cancer of the prostate. Partial atrophy and post-atrophic hyperplasia (hyperplastic atrophy) are the benign lesions that most often are confused with adenocarcinoma. One of the reasons that contribute to make the diagnosis of partial atrophy difficult is related to the absence of basal cell in some acini. More recently the application of AMACR (alpha-metilacil Co-enzyme A racemase) as a marker of malignant cells through immunohistochemistry has helped in the differential diagnosis with prostate cancer. However, its application in routine diagnosis is not yet established. The immunoexpression of AMACR may cause some doubt in interpretation. In literature there are few studies that reported the expression of AMACR in partial atrophy. We evaluated by immunohistochemistry the expression of AMACR and 34ßE12 (cytokeratin high-molecular weight) using the cocktail P504S +34ßE12 in 74 needle prostatic biopsies corresponding to 61 patients. We analyzed a total of 1198 prostate acini (324 acini with adenocarcinoma, 213 normal acini, 190 acini with partial atrophy, 298 acini with post-atrophic hyperplasia, 139 acini with simple atrophy and 34 acini with sclerosing atrophy). In adenocarcinoma acini the staining of AMACR was strong in 251/324 (77.5%) and weak in 73/324 (22.5%). There were no negative acini. In normal acini AMACR was strong in 13/213 (6.1%), weak in 33/213 (15.5%) and negative in 167/213 (78.4%). In partial atrophy, acini showed weak AMACR in 47/190 (24.7%) and were negative in 143/190 (75.3%). There was no strong staining in partial atrophy. The immunoexpression of AMACR was negative in all variants of complete atrophy: simple atrophy, hyperplastic atrophy and sclerosing atrophy.
Normal acini showed negative, weak, or strong expression in 167/213 (78.4%), 33/213 (15.5%), and 13/213 (6.1%) acini, respectively. Partial atrophy showed negative, and weak expression in 143/190 (75.3%), and 47/190(24.7%) acini, respectively. No strong positivity was seen in partial atrophy, however, the weak positivity seen in approximately 25% of the acini may be a pitfall for the correct interpretation in the differential diagnosis of cancer and partial atrophy. AMACR was negative in all acini of simple, postatrophic hyperplasia and sclerosing atrophy, therefore, with no help in the differential diagnosis of adenocarcinoma. The distribution of basal cells in simple, postatrophic hyperplasia and sclerotic atrophy was discontinuous and the cells of the secretory compartment showed aberrant expression of 34ßE12 suggesting an intermediate phenotype. Analyzing these results it is concluded that the differential diagnosis of prostate cancer with partial atrophy must be done carefully considering that the expression of AMACR, although weak in our study, can occur in about 25% of the acini. Furthermore, in 23.2% acini of partial atrophy the basal cells are absent. In some cases the microscopic identification of partial atrophy will rely only on morphologic criteria. / Mestrado / Ciencias Biomedicas / Mestre em Ciências Médicas
|
22 |
Enhanced biopsy and regional anaesthesia through ultrasound actuation of a standard needleSadiq, Muhammad January 2013 (has links)
There is an urgent and unmet clinical need to improve accuracy and safety during needle-based interventional procedures including regional anaesthesia and cancer biopsy. In ultrasound guided percutaneous needle procedures, there is a universal problem of imaging the needle, particularly the tip, especially in dense tissues and steep insertion angles. Poor visualization of the needle tip can have serious consequences for the patients including nerve damage and internal bleeding in regional anaesthesia and, in the case of biopsy, mis-sampling, resulting in misdiagnosis or the need for repeat biopsy. The aim of the work was to design and develop an ergonomic ultrasound device to actuate standard, unmodified needles such that the visibility of needle can be enhanced when observed under colour Doppler mode of ultrasound imaging. This will make the needle procedures efficient through accurate needle placement while reducing the overall procedure duration. The research reported in this thesis provides an insight into the new breed of piezoelectric materials. A methodology is proposed and implemented to characterize the new piezocrystals under ambient and extreme practical conditions. For the first time, the IEEE standard method (1987) was applied to an investigation of this type with binary (PMN-PT) and ternary (PIN-PMN-PT) compositions of piezocrystals. Using the existing data and the data obtained through characterization, finite element analysis (FEA) were carried to adequately design the ultrasound device. Various configurations of the device were modelled and fabricated, using both piezoceramic and piezocrystal materials, in order to assess the dependency of device’s performance on the configuration and type of piezoelectric material used. In order to prove the design concept and to measure the benefits of the device, pre-clinical trials were carried out on a range of specimens including the soft embalmed Thiel cadavers. Furthermore, an ultrasound planar cutting tool with various configurations was also designed and developed as an alternative to the existing cumbersome ultrasonic scalpels. These configurations were based on new piezocrystals including the Mn-doped ternary (Mn:PIN-PMN-PT) material. It is concluded that the needle actuating device can significantly enhance the visibility of standard needles and additionally benefits in reducing the penetration force. However, in order to make it clinically viable, further work is required to make it compliant with the medical environment. The piezocrystals tested under practical conditions although offer extraordinary piezoelectric properties, are vulnerable to extreme temperature and drive conditions. However, it is observed that newer piezocrystals, especially Mn:PIN-PMN-PT have shown the potential to replace the conventional piezoceramics in high power and actuator applications. Moreover, the d31-mode based planar cutting tool contrasts with the cumbersome design of mass-spring transducer structure and has the potential to be used in surgical procedures.
|
23 |
Fine needle aspiration cytology in the study of neck massChen, Xiuyun. January 2003 (has links)
published_or_final_version / Medical Sciences / Master / Master of Medical Sciences
|
24 |
Avaliação da variabilidade interobservador no diagnóstico histopatológico em biópsias de próstataSchumacher, Rita de Cássia Alves January 2006 (has links)
Introdução e objetivos: a punção-biópsia de próstata é a principal forma de diagnóstico do câncer de próstata. A introdução da dosagem sérica do PSA e os programas de rastreamento do câncer de próstata levaram à detecção de neoplasias subclínicas e de pequenas dimensões. A utilização da revisão cega de cortes histológicos no controle de qualidade dos exames permite a reavaliação, fornece a variabilidade interobservadores e possibilita a detecção de exames discrepantes, falsos negativos e positivos. Na próstata tal prática é justificável pela freqüência de diagnósticos de incerteza e de neoplasias de pequenas dimensões, que tornam a interpretação do exame mais difícil e subjetiva. O objetivo deste estudo é avaliar a variabilidade interobservador em biópsias de próstata. Material e métodos: dois patologistas revisaram separadamente 489 exames de biópsias de próstata. Os patologistas desconheciam o diagnóstico original e informações clínicas como valor do PSA, idade e toque retal,obtidos dos prontuários clínicos. A variabilidade interobservador foi quantificada através do índice Kappa. Resultados: foram revisadas biópsias provenientes de 191 pacientes. A média de idade foi de 65,5 anos e a média do PSA de 14,26 ng/ml (mediana=8,4 ng/ml). A concordância geral entre o diagnóstico original e o final (pós-revisão) foi de 94,3% e o índice kappa foi de 0,86 (com intervalo de confiança de 95% entre 0,8 e 0,91). O índice kappa entre os revisores foi de 0,83. A concordância entre os grupos de diagnóstico foi de 94,6% (kappa 0,85) para os exames benignos; 100% (k 0,99) nos adenocarcinomas; 76,5% (k 0,67) nas ASAPs – proliferações de pequenos ácinos atípicos e 50% (k 0,3) nas NIPs – neoplasias intraepiteliais prostáticas de alto grau. Conclusões: Este estudo mostrou a alta concordância interobservador nos diagnósticos benignos e adenocarcinomas. As maiores variações ocorreram nas lesões pré-malignas (NIP) e nos diagnósticos duvidosos, expressas por uma menor concordância interobservador e baixo índice kappa. A revisão cega de biópsias de próstata pode ser útil e deve ser recomendada nos caso duvidosos, onde há uma forte suspeita de neoplasia, uma vez que o diagnóstico de neoplasias pequenas e lesões pré-neoplásicas é de difícil interpretação e pode estar relacionada a uma maior variabilidade interobservador. / Introduction: prostate needle biopsy is the standard procedure for the diagnosis of prostate cancer. The introduction of PSA screening and other screening methods has allowed for the detection of subclinical and minimal carcinomas of the prostate. The blind review of histological sections for the quality control of exams permits reassessment, provides interobserver variability and allows the detection of discrepant exam results, false negatives and false positives. This practice is justified in case of the prostate, due to the frequently uncertain diagnoses and due to the presence of focal carcinoma, which render the interpretation of exam results more difficult and less objective. The aim of this study is to assess the interobserver variability in prostate biopsies carried out at a teaching hospital. Materials and Methods: two pathologists individually reviewed 489 prostate biopsies. Both pathologists were blinded to the original diagnosis and to clinical data such as PSA levels, age, and digital rectal examination status. Interobserver variability was measured using the kappa coefficient. Results: a total of 489 biopsies of 191 patients were reviewed. Mean patient age was 65.5 years, and PSA levels averaged 14.26 ng/ml (median:8,4ng/ml). Overall agreement between the original and final diagnoses was 94.3% with a kappa of 0.86 (95%CI between 0.8 and 0.91). The interobserver kappa value was 0.83. Agreement among diagnostic groups was 94.6% (kappa = 0.85) for benign exams; 100% (kappa = 0.99) for adenocarcinomas; 76.5% (kappa = 0.67) for atypical small acinar proliferations (ASAP) and 50% (kappa = 0.3) for high-grade prostatic intraepithelial neoplasias (HGPIN). Conclusions: The blind review of prostate biopsies can be useful and is recommended in uncertain cases highly suspicious of malignancy, since the diagnosis of minimal carcinoma and preneoplastic lesions is difficult and is related to a larger interobserver variability.
|
25 |
Avaliação da variabilidade interobservador no diagnóstico histopatológico em biópsias de próstataSchumacher, Rita de Cássia Alves January 2006 (has links)
Introdução e objetivos: a punção-biópsia de próstata é a principal forma de diagnóstico do câncer de próstata. A introdução da dosagem sérica do PSA e os programas de rastreamento do câncer de próstata levaram à detecção de neoplasias subclínicas e de pequenas dimensões. A utilização da revisão cega de cortes histológicos no controle de qualidade dos exames permite a reavaliação, fornece a variabilidade interobservadores e possibilita a detecção de exames discrepantes, falsos negativos e positivos. Na próstata tal prática é justificável pela freqüência de diagnósticos de incerteza e de neoplasias de pequenas dimensões, que tornam a interpretação do exame mais difícil e subjetiva. O objetivo deste estudo é avaliar a variabilidade interobservador em biópsias de próstata. Material e métodos: dois patologistas revisaram separadamente 489 exames de biópsias de próstata. Os patologistas desconheciam o diagnóstico original e informações clínicas como valor do PSA, idade e toque retal,obtidos dos prontuários clínicos. A variabilidade interobservador foi quantificada através do índice Kappa. Resultados: foram revisadas biópsias provenientes de 191 pacientes. A média de idade foi de 65,5 anos e a média do PSA de 14,26 ng/ml (mediana=8,4 ng/ml). A concordância geral entre o diagnóstico original e o final (pós-revisão) foi de 94,3% e o índice kappa foi de 0,86 (com intervalo de confiança de 95% entre 0,8 e 0,91). O índice kappa entre os revisores foi de 0,83. A concordância entre os grupos de diagnóstico foi de 94,6% (kappa 0,85) para os exames benignos; 100% (k 0,99) nos adenocarcinomas; 76,5% (k 0,67) nas ASAPs – proliferações de pequenos ácinos atípicos e 50% (k 0,3) nas NIPs – neoplasias intraepiteliais prostáticas de alto grau. Conclusões: Este estudo mostrou a alta concordância interobservador nos diagnósticos benignos e adenocarcinomas. As maiores variações ocorreram nas lesões pré-malignas (NIP) e nos diagnósticos duvidosos, expressas por uma menor concordância interobservador e baixo índice kappa. A revisão cega de biópsias de próstata pode ser útil e deve ser recomendada nos caso duvidosos, onde há uma forte suspeita de neoplasia, uma vez que o diagnóstico de neoplasias pequenas e lesões pré-neoplásicas é de difícil interpretação e pode estar relacionada a uma maior variabilidade interobservador. / Introduction: prostate needle biopsy is the standard procedure for the diagnosis of prostate cancer. The introduction of PSA screening and other screening methods has allowed for the detection of subclinical and minimal carcinomas of the prostate. The blind review of histological sections for the quality control of exams permits reassessment, provides interobserver variability and allows the detection of discrepant exam results, false negatives and false positives. This practice is justified in case of the prostate, due to the frequently uncertain diagnoses and due to the presence of focal carcinoma, which render the interpretation of exam results more difficult and less objective. The aim of this study is to assess the interobserver variability in prostate biopsies carried out at a teaching hospital. Materials and Methods: two pathologists individually reviewed 489 prostate biopsies. Both pathologists were blinded to the original diagnosis and to clinical data such as PSA levels, age, and digital rectal examination status. Interobserver variability was measured using the kappa coefficient. Results: a total of 489 biopsies of 191 patients were reviewed. Mean patient age was 65.5 years, and PSA levels averaged 14.26 ng/ml (median:8,4ng/ml). Overall agreement between the original and final diagnoses was 94.3% with a kappa of 0.86 (95%CI between 0.8 and 0.91). The interobserver kappa value was 0.83. Agreement among diagnostic groups was 94.6% (kappa = 0.85) for benign exams; 100% (kappa = 0.99) for adenocarcinomas; 76.5% (kappa = 0.67) for atypical small acinar proliferations (ASAP) and 50% (kappa = 0.3) for high-grade prostatic intraepithelial neoplasias (HGPIN). Conclusions: The blind review of prostate biopsies can be useful and is recommended in uncertain cases highly suspicious of malignancy, since the diagnosis of minimal carcinoma and preneoplastic lesions is difficult and is related to a larger interobserver variability.
|
26 |
Avaliação da variabilidade interobservador no diagnóstico histopatológico em biópsias de próstataSchumacher, Rita de Cássia Alves January 2006 (has links)
Introdução e objetivos: a punção-biópsia de próstata é a principal forma de diagnóstico do câncer de próstata. A introdução da dosagem sérica do PSA e os programas de rastreamento do câncer de próstata levaram à detecção de neoplasias subclínicas e de pequenas dimensões. A utilização da revisão cega de cortes histológicos no controle de qualidade dos exames permite a reavaliação, fornece a variabilidade interobservadores e possibilita a detecção de exames discrepantes, falsos negativos e positivos. Na próstata tal prática é justificável pela freqüência de diagnósticos de incerteza e de neoplasias de pequenas dimensões, que tornam a interpretação do exame mais difícil e subjetiva. O objetivo deste estudo é avaliar a variabilidade interobservador em biópsias de próstata. Material e métodos: dois patologistas revisaram separadamente 489 exames de biópsias de próstata. Os patologistas desconheciam o diagnóstico original e informações clínicas como valor do PSA, idade e toque retal,obtidos dos prontuários clínicos. A variabilidade interobservador foi quantificada através do índice Kappa. Resultados: foram revisadas biópsias provenientes de 191 pacientes. A média de idade foi de 65,5 anos e a média do PSA de 14,26 ng/ml (mediana=8,4 ng/ml). A concordância geral entre o diagnóstico original e o final (pós-revisão) foi de 94,3% e o índice kappa foi de 0,86 (com intervalo de confiança de 95% entre 0,8 e 0,91). O índice kappa entre os revisores foi de 0,83. A concordância entre os grupos de diagnóstico foi de 94,6% (kappa 0,85) para os exames benignos; 100% (k 0,99) nos adenocarcinomas; 76,5% (k 0,67) nas ASAPs – proliferações de pequenos ácinos atípicos e 50% (k 0,3) nas NIPs – neoplasias intraepiteliais prostáticas de alto grau. Conclusões: Este estudo mostrou a alta concordância interobservador nos diagnósticos benignos e adenocarcinomas. As maiores variações ocorreram nas lesões pré-malignas (NIP) e nos diagnósticos duvidosos, expressas por uma menor concordância interobservador e baixo índice kappa. A revisão cega de biópsias de próstata pode ser útil e deve ser recomendada nos caso duvidosos, onde há uma forte suspeita de neoplasia, uma vez que o diagnóstico de neoplasias pequenas e lesões pré-neoplásicas é de difícil interpretação e pode estar relacionada a uma maior variabilidade interobservador. / Introduction: prostate needle biopsy is the standard procedure for the diagnosis of prostate cancer. The introduction of PSA screening and other screening methods has allowed for the detection of subclinical and minimal carcinomas of the prostate. The blind review of histological sections for the quality control of exams permits reassessment, provides interobserver variability and allows the detection of discrepant exam results, false negatives and false positives. This practice is justified in case of the prostate, due to the frequently uncertain diagnoses and due to the presence of focal carcinoma, which render the interpretation of exam results more difficult and less objective. The aim of this study is to assess the interobserver variability in prostate biopsies carried out at a teaching hospital. Materials and Methods: two pathologists individually reviewed 489 prostate biopsies. Both pathologists were blinded to the original diagnosis and to clinical data such as PSA levels, age, and digital rectal examination status. Interobserver variability was measured using the kappa coefficient. Results: a total of 489 biopsies of 191 patients were reviewed. Mean patient age was 65.5 years, and PSA levels averaged 14.26 ng/ml (median:8,4ng/ml). Overall agreement between the original and final diagnoses was 94.3% with a kappa of 0.86 (95%CI between 0.8 and 0.91). The interobserver kappa value was 0.83. Agreement among diagnostic groups was 94.6% (kappa = 0.85) for benign exams; 100% (kappa = 0.99) for adenocarcinomas; 76.5% (kappa = 0.67) for atypical small acinar proliferations (ASAP) and 50% (kappa = 0.3) for high-grade prostatic intraepithelial neoplasias (HGPIN). Conclusions: The blind review of prostate biopsies can be useful and is recommended in uncertain cases highly suspicious of malignancy, since the diagnosis of minimal carcinoma and preneoplastic lesions is difficult and is related to a larger interobserver variability.
|
27 |
Análise comparativa da punção aspirativa por agulha fina (PAAF) em relação a biópsia em cavidade oral e região de cabeça e pescoço / Comparative analysis of Fine Needle Aspiration Biopsy (FNAB) versus biopsy in oral cavity and head and neck regionAna Paula Candido dos Santos 22 October 2010 (has links)
O presente estudo teve como objetivos avaliar a sensibilidade, a especificidade e a acurácia da Punção Aspirativa por Agulha Fina (PAAF) em nódulos submucosos da cavidade bucal e da região de cabeça e pescoço como ferramenta auxiliar de diagnóstico. Foram selecionados 50 pacientes consecutivamente que procuraram a Clínica da Disciplina de Estomatologia Clínica da FOUSP, portadores de lesões em boca e em região de cabeça e pescoço. O material obtido pela PAAF foi enviado a um mesmo patologista apenas com o diagnóstico clínico e após a emissão do laudo da PAAF o laudo do anátomo patológico era emitido servindo como padrão ouro. Após os cálculos, o resultado da sensibilidade foi de 75%, a especificidade foi de 96%, a acurácia foi de 58,8%, o valor preditivo positivo foi de 86% e o valor preditivo negativo foi de 93%. A significância foi estabelecida para 5% e o teste usado foi o teste de Kappa com valor de P<0,001 e um teste qui-quadrado, com valor de P=0,788. Pela análise dos resultados a PAAF teve uma alta sensibilidade para identificar lesões malignas, uma alta especificidade para identificar lesões benignas e uma baixa acurácia para se obter um diagnóstico definitivo. / The objectives of this present study are to evaluate the sensitivity, specificity and accuracy of Fine Needle Aspiration Biopsy (FNAB) in submucous nodules of oral cavity and nodules of head and neck region as an auxiliary tool of diagnoses. 50 patients that looked for the Clinic of the Discipline of Oral Stomatology of FOUSP were consecutively selected, carrying lesions in the oral cavity and the head and neck region. The material obtained by FNA was sent to only one pathologist with the clinical diagnosis and after the emission of FNAB report the biopsy report was emitted serving as the gold standard. After the calculation, the results of sensibility was 75%, the specificity was 96%, the accuracy was 58,8%, the positive predict value was 86% and the negative predict value was 93%. The significance was established for 5% and the tests used was Kappa with P<0,001 and a Chi-square with a P value of 0,778.With the results analysis the FNAB had a high sensibility to identify malignant lesions, a high specificity to identify benign lesions and a low accuracy to obtain final diagnoses.
|
28 |
Ancillary methods to improve diagnostic accuracy of thyroid nodules on fine-needle aspiration cytology smearsVan Wyk, Christine 12 1900 (has links)
Thesis (MScMed (Dept. of Biomedical Sciences. Anatomy and Histology) --University of Stellenbosch, 2007. / Thyroid nodules are a common clinical problem encountered by physicians, surgeons and radiologists who deal with the head and neck region. However, most follicular lesions of the thyroid are benign, so that the indications for surgery should be as accurate as possible. The morphological difficulty on fine-needle aspiration biopsy (FNAB) of reliably distinguishing preoperatively between benign and malignant lesions has led to a search for ancillary methods that can assist with the diagnosis.
The aim of the first study was to develop a cytological scoring system to improve diagnostic accuracy of fine-needle aspiration biopsy of papillary carcinomas with special reference to the follicular variant of papillary carcinoma. The objective of the second study was the application of immunodiagnostic markers Galectin-3 and HBME-1 to histology tissue sections and their corresponding fine-needle aspiration cytology smears to assess their value in distinguishing benign from malignant thyroid lesions.
In the first study 16 different cytological features such as background, architecture and cellular morphology were quantatively assessed and scored. Only 14 of the 16 variables were statistically significant. The statistical analysis demonstrated that a score ≥ 4 was indicative of a papillary carcinoma with a sensitivity of 96%. A score < 4 suggested a benign multinodular goiter with a specificity of 97%.
In the second study Galectin-3 and HBME-1 were applied to histology tissue sections and their corresponding fine-needle aspiration cytology smears. Statistical analyses showed that the sensitivity of immunohistochemistry for diagnosing malignancy was better than the immunocytochemistry, but the specificity of immunocytochemistry was superior. Furthermore the diagnostic accuracy of immunohistochemistry (86%) and immunocytochemistry (88%) using co-expression of these two antibodies was excellent. In this study on immunocytochemistry, papillary carcinomas were clearly identified with a 100% co-expression in the classic and 71% in the follicular variant of papillary carcinoma. For the surgeon the identification of papillary carcinoma is critical, as this determines the extent of surgery. Similary, the confirmation of a non-neoplastic lesion may prevent surgery. In most cases follicular neoplasms, benign or malignant, will usually be excised for histopathology, prior to definite therapy.
These studies show that the implementation of ancillary methods such as a scoring system and immunodiagnostic markers can improve the diagnostic accuracy of thyroid fine-needle aspiration biopsies in our laboratory. This may lead to better management of thyroid nodules. However, it is advisable that cytopathologists always take all the clinical features and image analyses into consideration before making a diagnosis.
|
29 |
Simulador de realidade virtual para o treinamento de biópsia por agulha de nódulos da glândula tireóide. / Virtual reality simulator for training of thyroid gland nodules needle biopsy.Souza, Ilana de Almeida 30 November 2007 (has links)
A biópsia por agulha fina é um procedimento importante na investigação de tumores, considerado de baixo-custo, minimamente invasivo e ideal para o fornecimento de um diagnóstico preciso em casos de nódulos da glândula tireóide. Para a realização bem sucedida da biópsia por agulha, a exatidão é essencial e a prática proporciona benefícios significativos tanto na recuperação do paciente, quanto na obtenção de resultados acurados. Esta tese investigou a possibilidade do desenvolvimento de um simulador de realidade virtual para treinamento de biópsia guiada por ultrassom de nódulos da glândula tireóide. O simulador de realidade virtual proposto e desenvolvido é também uma ferramenta educativa, pois além de praticar o procedimento, o usuário pode visualizar tanto um modelo da tireóide para sentir sua textura, quanto um modelo completo do pescoço com todos os seus órgãos internos, podendo ser rotacionado. O sistema consiste de duas interfaces: uma tridimensional, apresentando os modelos virtuais com estereoscopia na mesa de visualização, cuja interação do usuário é feita através do teclado ou dispositivo háptico (Phantom OmniTM); e uma segunda que simula o exame de ultrassom, com todas as funcionalidades de um exame real, sendo manipulada pelo mouse. As duas se comunicam e todo o processo é mostrado na janela do instrutor, que substitui o supervisor orientando o usuário durante o treinamento. O simulador de realidade virtual foi avaliado experimentalmente por profissionais da área médica e tecnológica, sendo aprovado como uma ferramenta para treinamento e ensino de biópsia de nódulos da glândula tireóide. / The fine needle biopsy is an important procedure to investigations in tumors, low-cost considered, minimally invasive and ideal for supplying an accurate diagnosis in cases of thyroid gland nodules. The exactness is essential for the successful accomplishment of the needle biopsy and the practice provides significant benefits in the recovery of the patient, as well as in attainment of accurate results. This thesis investigated the possibility of the development of virtual reality simulator for the training of the ultrasound guided needle biopsy of thyroid gland nodules. The proposed and developed virtual reality simulator is also an educative tool, because besides practicing the procedure, the user can visualize thyroid model to feel its texture, as well as a complete model of the neck with all its internal organs and it can be rotated. The system consists of two interfaces: first is a three-dimensional which presents the virtual models with stereoscopy in the visualization table, whose interaction of the user is made through the keyboard or haptic device (Phantom OmniTM); and second one that simulates the ultrasound images, with all the functionalities of a real examination, manipulated by the mouse. The two interfaces communicate with each other and all the process is shown in the instructor window that substitutes the supervisor and guides the user during the training. The virtual reality simulator was experimentally evaluated by professionals of the medical and technological areas, being approved as a tool for training and education in needle biopsy of the thyroid gland nodules.
|
30 |
Simulador de realidade virtual para o treinamento de biópsia por agulha de nódulos da glândula tireóide. / Virtual reality simulator for training of thyroid gland nodules needle biopsy.Ilana de Almeida Souza 30 November 2007 (has links)
A biópsia por agulha fina é um procedimento importante na investigação de tumores, considerado de baixo-custo, minimamente invasivo e ideal para o fornecimento de um diagnóstico preciso em casos de nódulos da glândula tireóide. Para a realização bem sucedida da biópsia por agulha, a exatidão é essencial e a prática proporciona benefícios significativos tanto na recuperação do paciente, quanto na obtenção de resultados acurados. Esta tese investigou a possibilidade do desenvolvimento de um simulador de realidade virtual para treinamento de biópsia guiada por ultrassom de nódulos da glândula tireóide. O simulador de realidade virtual proposto e desenvolvido é também uma ferramenta educativa, pois além de praticar o procedimento, o usuário pode visualizar tanto um modelo da tireóide para sentir sua textura, quanto um modelo completo do pescoço com todos os seus órgãos internos, podendo ser rotacionado. O sistema consiste de duas interfaces: uma tridimensional, apresentando os modelos virtuais com estereoscopia na mesa de visualização, cuja interação do usuário é feita através do teclado ou dispositivo háptico (Phantom OmniTM); e uma segunda que simula o exame de ultrassom, com todas as funcionalidades de um exame real, sendo manipulada pelo mouse. As duas se comunicam e todo o processo é mostrado na janela do instrutor, que substitui o supervisor orientando o usuário durante o treinamento. O simulador de realidade virtual foi avaliado experimentalmente por profissionais da área médica e tecnológica, sendo aprovado como uma ferramenta para treinamento e ensino de biópsia de nódulos da glândula tireóide. / The fine needle biopsy is an important procedure to investigations in tumors, low-cost considered, minimally invasive and ideal for supplying an accurate diagnosis in cases of thyroid gland nodules. The exactness is essential for the successful accomplishment of the needle biopsy and the practice provides significant benefits in the recovery of the patient, as well as in attainment of accurate results. This thesis investigated the possibility of the development of virtual reality simulator for the training of the ultrasound guided needle biopsy of thyroid gland nodules. The proposed and developed virtual reality simulator is also an educative tool, because besides practicing the procedure, the user can visualize thyroid model to feel its texture, as well as a complete model of the neck with all its internal organs and it can be rotated. The system consists of two interfaces: first is a three-dimensional which presents the virtual models with stereoscopy in the visualization table, whose interaction of the user is made through the keyboard or haptic device (Phantom OmniTM); and second one that simulates the ultrasound images, with all the functionalities of a real examination, manipulated by the mouse. The two interfaces communicate with each other and all the process is shown in the instructor window that substitutes the supervisor and guides the user during the training. The virtual reality simulator was experimentally evaluated by professionals of the medical and technological areas, being approved as a tool for training and education in needle biopsy of the thyroid gland nodules.
|
Page generated in 0.0635 seconds