1

Logistika obchodních řetězců / Logistics of retail chains

Králová, Veronika January 2010 (has links)
This diploma thesis aims to review and assess a current state of Czech retail market with fast-moving consumer goods and to analyze a logistic base of leading retail chains doing business in the Czech Republic. A reader can learn about development of retail in the last few years, but also about prediction of the future trends. Based on the theoretical background regarding retail and logistics, the analysis of particular leading companies is made. Moreover, possible future efficiency improvements of companies' process which could lead to better market position are considered. The result of the thesis is the clear picture of well operating retail chain, its logistics and a flow of the goods into the retail market as a whole.
2

Controle inteligente de press?o para uma rede sem reservat?rio de abastecimento urbano de ?gua

Oliveira, Jos? Kleber Costa de 04 May 2012 (has links)
Made available in DSpace on 2014-12-17T14:56:01Z (GMT). No. of bitstreams: 1 JoseKCO_DISSERT.pdf: 2360607 bytes, checksum: ad43aaed1b6651cd3d8e3ffe4e2f5b67 (MD5) Previous issue date: 2012-05-04 / The sanitation companies from Brazil has a great challenge for the XXI century: seek to mitigate the rate of physical waste (water, chemicals and electricity) and financial waste caused by inefficient operating systems drinking water supply, considering that currently we already face, in some cases, the scarcity of water resources. The supply systems are increasingly complex as they seek to minimize waste and at the same time better serve the growing number of users. However, this technological change is to reduce the complexity of the challenges posed by the need to include users with higher quality and efficiency in services. A major challenge for companies of water supplies is to provide a good quality service contemplating reducing expenditure on electricity. In this situation we developed a research by a method that seeks to control the pressure of the distribution systems that do not have the tank in your setup and the water comes out of the well directly to the distribution system. The method of pressure control (intelligent control) uses fuzzy logic to eliminate the waste of electricity and the leaks from the production of pumps that inject directly into the distribution system, which causes waste of energy when the consumption of households is reduced causing the saturation of the distribution system. This study was conducted at Green Club II condominium, located in the city of Parnamirim, state of Rio Grande do Norte, in order to study the pressure behavior of the output of the pump that injects water directly into the distribution system. The study was only possible because of the need we had to find a solution to some leaks in the existing distribution system and the extensions of the respective condominium residences, which sparked interest in developing a job in order to carry out the experiments contained in this research / As empresas de saneamento do Brasil t?m um grande desafio para o s?culo XXI, procurar diminuir o ?ndice de desperd?cios f?sicos (?gua, produtos qu?micos e energia el?trica) e financeiros causados pela inefici?ncia operacional dos sistemas de abastecimento de ?gua pot?vel, levando-se em considera??o que atualmente j? se enfrenta, em alguns casos, a escassez dos recursos h?dricos. Os sistemas de abastecimento est?o cada vez mais complexos porque buscam minimizar os desperd?cios e ao mesmo tempo atender melhor ao crescente n?mero de usu?rios. Contudo, a evolu??o tecnol?gica est? presente para diminuir a complexidade dos desafios hora impostos pela necessidade de contemplar os usu?rios com maior qualidade e efici?ncia nos servi?os. Um dos grandes desafios para as empresas de abastecimento de ?gua est? em proporcionar um servi?o de boa qualidade contemplando a diminui??o das despesas com energia el?trica. Diante disso, desenvolveu-se um trabalho de pesquisa atrav?s de um m?todo que busca controlar a press?o da rede de distribui??o em sistemas que n?o apresentam na sua configura??o o reservat?rio e, por isso a ?gua sai do po?o diretamente para a rede de distribui??o. O m?todo de controle da press?o (controle inteligente) utiliza a l?gica fuzzy para eliminar o desperd?cio de energia el?trica e os vazamentos provocados pela produ??o das bombas que injetam diretamente na rede de distribui??o, provocando desperd?cio de energia quando o consumo das resid?ncias ? reduzido causando o saturamento da rede. Esse trabalho foi realizado no condom?nio Green Club II, situado na cidade de Parnamirim - RN, com o objetivo de estudar o comportamento da press?o da bomba que injeta diretamente na rede de distribui??o. O estudo s? foi poss?vel em virtude da necessidade que havia de se encontrar uma solu??o para alguns vazamentos existentes na rede de distribui??o e nos ramais das resid?ncias do respectivo condom?nio, fato que despertou o interesse em desenvolver um trabalho com o intuito de realizar as experi?ncias contidas nesta pesquisa
3

Analýza paralelního provozu uzlových oblastí 110 kV TR Krasíkov a TR Neznášov / Analysis of parallel operation of nodal areas of 110 kV Krasikov and Neznasov transformers stations

Kostkan, Petr January 2018 (has links)
Currently, the nodal areas of Neznášov substation and Krasíkov substation, which belong to ČEZd distribution network 110 kV – East, are operand as separate units. In the defined setting, each nodal area comprises of two 400/110 kV transformers. In the case of failure of the transformer T401 or T402, the criterion N-1 for twenty percent of the rated output is not met. Such problem can be solved by parallel operation of nodal areas of Neznášov substation and Krasíkov substation. The principal as well as practical aim of this thesis is to interconnect the bridge operated connection in separated areas into parallel/loop operation of nodal areas (supplied by 400/110 kV transformers). Computing software is used to calculate the steady state and short-circuit conditions in the distribution network 110 kV for separate and parallel operation of mentioned nodal areas. Power flow analysis is aimed at assessment and evaluation of voltage conditions, transformers loading (400/110 kV and 110/vn) as well as 110 kV lines loading. Obtained short-circuit indices is used to examine short-circuit, withstand capability of the 110 kV substation. Finally, benefits as well as drawbacks of the separate and parallel operation are compared and evaluated. If necessary, the technical arrangements are proposed/designed in order to allow parallel operation of nodal areas Neznášov substation and Krasíkov substation.
4

Ustálený chod a zkratové poměry v síti 110 kV E.ON napájené z rozvodny 110 kV Otrokovice v roce 2011 / Stabilized operation and short - circuit conditions within E.ON 110 kV power network supplied from Otrokovice 110kV switching station, during the period of 2011

Jurča, Ondřej January 2011 (has links)
Distribution network 110 kV owned by E. ON in the area Otrokovice; powered by 110 kV and two variants of involvement contained.The first option is basic involvement, without the use of the bridge. The second option includes involvement with the bridge. The aim of this study is to compare; by calculating the steady-state network operation and short circuit conditions of the network, the involvement of these two options. The thesis is divided into two parts, theoretical and practical. The theoretical part consists of a description of the steady operation of networks of high-voltage and short circuit ratio calculations. Load flow calculations are described by the Gauss-Seidel and Newton iterative method. In the case of short-circuit conditions, the effects of their characteristic values, processes and various methods of calculation are described.In the second part, this theoretical knowledge is applied to input data and dispatching programme with the appropriate calculations of network operation and short circuit conditions. The calculated values are listed in the thesis, on the basis of which an evaluation of the two possible connections is made.
5

Distribuční soustava Kypru - realizovatelnost obnovitelných zdrojů a přenos energie / Distribution system of Cyprus - feasibility of renewable energy sources and transfer of energy

Šimonová, Lucie January 2011 (has links)
Until a few decades ago few people could imagine that the photovoltaic, solar thermal and other power based on renewable resources, will become a reality. Today people from all over the world on the contrary try at full blast derive benefit from of all possible available source. Using sunlight as a source of energy is first enforced only for small devices such as calculators for charging the battery, but now we are able to produced energy from the sun to supply people around the world. Of course it is not possible supply consumer sector plus firm only from performances renewable power supply. Therefore endeavour is derive benefit from classical energy production at the same time with others power supply. The basic components of photovoltaic and solar thermal power are panels. The panels are made of different materials in different shapes and sizes. During production, the resulting effect looks in addition to costs associated with production. For photovoltaic and solar thermal power plant requires sufficient sunlight. The sunshine has biggest intensity on south of ours planets. Therefore endeavour is build lump these power station just in stand with bigger intensity sunshine. One of them is just Cyprus, too.