• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo clínico observacional da facoemulsificação com ultra-som torsional na microincisão coaxial de 2,2 mm.

Araújo, André Gustavo Rolim de January 2008 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, 2008. / Submitted by Ruthléa Nascimento (ruthlea@bce.unb.br) on 2008-10-30T15:42:39Z No. of bitstreams: 1 2008_AndreGustavoRAraujo.pdf: 3310922 bytes, checksum: 700bafc4dbcea13b576c2d77fe094297 (MD5) / Approved for entry into archive by Luanna Maia(luanna@bce.unb.br) on 2009-02-26T16:27:11Z (GMT) No. of bitstreams: 1 2008_AndreGustavoRAraujo.pdf: 3310922 bytes, checksum: 700bafc4dbcea13b576c2d77fe094297 (MD5) / Made available in DSpace on 2009-02-26T16:27:12Z (GMT). No. of bitstreams: 1 2008_AndreGustavoRAraujo.pdf: 3310922 bytes, checksum: 700bafc4dbcea13b576c2d77fe094297 (MD5) / Objetivo: Avaliar clinicamente o desempenho da cirurgia de catarata por facoemulsificação com tecnologia torsional Infiniti Vision SystemTM – OZilTM U/S Torsional® e incisão microcoaxial em córnea clara de 2,2 mm. Métodos: Estudo clínico observacional de 96 olhos com catarata nuclear ou córtico-nuclear grau 2 de acordo com o Sistema de Classificação de Opacidades Lenticulares III, submetidos à cirurgia de facoemulsificação com incisão microcoaxial de 2,2 mm e tecnologia torsional OZiL (OZilTM U/S Torsional® com Infiniti Vision SystemTM no Hospital Oftalmológico de Brasília. Foram analisadas variáveis intra-operatórias de volume de solução salina balanceada (SSB) infundida, tempo cirúrgico (TC) e energia ultra-sônica dissipada acumulada (EDA); variáveis pré e pós-operatórias de um dia e um mês de paquimetria central da córnea (PCC) e densidade de células endoteliais da córnea (DCE). Resultados: Na análise do parâmetro intra-operatório de volume médio de SSB, em ml, utilizado durante a cirurgia, foi de 97,3 com desvio padrão (DP) de ± 9,62. O TC médio foi de 5,08 com DP de ± 0,53. A EDA média dos procedimentos foi de 3,23 com DP de ± 0,39. Os valores médios da PCC, em μm, analisados no pré-operatório, pós-operatório com um dia e um mês foram, respectivamente, 538,98, 545,34 e 541,78 (p-valor 0,05). Os valores médios da DCE, em células por mm2, analisados no pré-operatório, pós-operatório com um dia e um mês foram, respectivamente, 2321, 2281, 2230 (p valor 0,05). A redução percentual da DCE foi de 1,7% no primeiro dia pós-operatório e 4% após um mês da cirurgia. Conclusão: A técnica de facoemulsificação com tecnologia – OZilTM U/S Torsional® e incisão microcoaxial em córnea clara de 2,2 mm parece não afetar prejudicialmente o endotélio corneano, avaliado através dos parâmetros de PCC, DCE, EDA e volume de SSB infundido. _______________________________________________________________________________________ ABSTRACT / Objective: to clinically evaluate the performance of the phacoemulsification cataract surgery using the torsional technology Infiniti Vision SystemTM - OZilTM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision. Methods: observational clinical study comprising 96 eyes with nuclear or cortico-nuclear cataract grade 2 according to Lens Opacities Classification System III submitted to phacoemulsification cataract surgery using the torsional technology Infiniti Vision SystemTM - OZilTM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision at Hospital Oftalmológico de Brasília. Intra-operative variables of used volume of balanced salt solution, surgical time and accumulated dissipated ultrasound energy were analysed. Pre and one-day and one-month post-operative variables of central corneal thickness and corneal endothelial density were also analysed. Results: the mean volume of used balanced salt solution, in ml, was 97,3 with standard deviation of ± 9,62. The mean surgical time, in minutes, was 5,08 with standard deviation of ± 0,53. The mean accumulated dissipated ultrasound energy was 3,23 with standard deviation of ± 0,39. The pre-operative, one-day and one-month post-operative mean values, in μm, of central corneal thickness were, respectively, 538,98, 545,34 and 541,78 (p value 0,05). The pre-operative, one-day and one-month post-operative mean values of corneal endothelial density, in cells per mm2, were, respectively, 2321, 2281, 2230 (p value 0,05). The percentage decrease in corneal endothelial density at first post-operative day was 1,7% and at first post-operative month was 4%. Conclusion: the phacoemulsification technique with the torsional technology Infiniti Vision SystemTM - OZil TM U/S Torsional® with 2,2 mm clear corneal microcoaxial incision seems not to damage or affect negatively the corneal endothelium as suggested by the variables analysed.
2

Uso de biópticos (ICL y Lasik) para la corrección de la alta miopía

Puig Galy, Javier José 16 May 2001 (has links)
OBJETIVOS: Determinar la eficacia, predictibilidad, estabilidad y seguridad de la cirugía refractiva mediante "Biópticos" (combinación del implante de una lente fáquica de cámara posterior y láser in situ queratomileusis) en pacientes afectos de altas miopías.Describir el procedimiento quirúrgico y mostrar los resultados visuales y refractivos del mismo.MATERIAL Y MÉTODOS:Hemos analizado 102 ojos de 63 pacientes afectos de alta miopía, intervenidos mediante el implante de una lente fáquica de cámara posterior tipo ICLTM y láser in situ queratomileusis (Lasik).El seguimiento postoperatorio medio fue de 19 meses (rango: 12-36 meses).RESULTADOS:El equivalente esférico medio preoperatorio fue de -18,20 ± 4,21 D., con un astigmatismo medio asociado de -1,87 ± 1,57 D. La media aritmética del equivalente esférico tras implantar la lente fáquica y antes de realizar el Lasik fue de -2,59 ± 2,04 D. El equivalente esférico medio tras el procedimiento Bióptico completo resultó ser de -0,28 ± 0,33 D., con un cilindro medio de -0,53 ± 0,35 D.El 100% de los pacientes se encontraban postoperatoriamente en el rango de ± 1,00 D. respecto a la emetropía, mientras el 95,09% lo hacían en el rango de ± 0,50 D.Las refracciones postoperatorias se mantuvieron estables durante los sucesivos controles, sin cambios estadísticamente significativos.La agudeza visual sin corrección mejoró en todos los casos. La agudeza visual corregida se mantuvo igual o mejoró postoperatoriamente en todos los casos excepto en dos. La media de ganancia de agudeza visual corregida postoperatoria fue de dos líneas de Snellen.Todos los pacientes se mostraron muy satisfechos con los resultados obtenidos.DISCUSIÓN:El uso combinado de lentes fáquicas de cámara posterior tipo ICLTM y Láser in situ queratomileusis (Lasik) constituye un método efectivo y predecible para corregir la alta miopía.Es frecuente la mejoría postoperatoria de la agudeza visual corregida de estos pacientes. Los resultados muestran una considerable seguridad del procedimiento a corto y medio plazo, así como una gran estabilidad refractiva. / PURPOSE: To determine the efficacy, predictability, stability and safety of "Bioptics" refractive surgery (combined posterior chamber phakic intraocular lens implantation and laser in situ keratomileusis) in eyes with extreme myopia. To report the technique and to assess the results (refraction and visual acuity) of this surgical procedure.MATERIAL AND METHODS: We analyzed the results of 102 eyes that received a posterior chamber hydrogel-collagen plate phakic IOL (ICLTM) and also underwent secondary Lasik for the correction of extreme myopia. Mean follow-up was 19 months after the Lasik procedure (range 12 to 36 months).RESULTS: Mean preoperative spherical equivalent refraction was -18,20 ± 4,21 D., and mean refractive cylinder was -1,87 ± 1,57 D. Mean spherical equivalent refraction after IOL implantation and before Lasik was -2,59 ± 2,04 D. Mean postoperative spherical equivalent refraction one year after the Lasik portion of the double Bioptics procedure was -0,28 ± 0,33 D., and mean refractive cylinder was -0,53 ± 0,35 D.One hundred percent were within ± 1,00 D. and 95,09 % were within ± 0,50 D. of emmetropia at last examination.The refractions remained stable with a statistically insignificant change during follow-up.Uncorrected visual acuity improved in all cases. Best spectacle-corrected acuity remained the same or improved in all but two cases. Mean best spectacle-corrected acuity gain after the double procedure was two Snellen lines.Patient satisfaction with the final visual outcome was very high.CONCLUSIONS: Combined posterior chamber phakic IOL implantation with ICLTM lens and Lasik (Bioptics) is an effective and reasonably predictable method for correcting high myopia. Gains in spectacle-corrected visual acuity were common, and results demonstrated good short-medium term safety and refractive stability.
3

Proposta de inovação no sistema de aquisição de imagens aplicado em retinógrafos digitais / Proposal of innovation in the imaging system applied in digital fundus camera

Flávio Pascoal Vieira 12 April 2013 (has links)
A retinografia e angiografia digital são técnicas de observação e captura de imagens do fundo do olho que permitem o diagnóstico de diversas patologias. O aperfeiçoamento dos retinógrafos digitais, viabilizado pelos avanços tecnológicos observados nas últimas décadas, tornou possíveis modificações sistêmicas inovadoras como a apresentada e discutida neste trabalho. O principal objetivo é avaliar comparativamente a resolução espacial de imagens captadas com uma configuração que utiliza apenas um sensor monocromático e um conjunto de LEDs cromáticos, com imagens geradas por um sensor com filtro cromático integrado. A proposta é suportada por resultados teóricos que indicam um desempenho superior do uso de sensores monocromáticos em retinografia. Para validação da nova metodologia o sistema descrito foi montado e várias fotos da retina foram capturadas. Todo o processo de imageamento do fundo do olho é descrito, incluindo rotinas de software que precisaram ser criadas em decorrência das inovações. A partir das imagens capturadas foram aplicadas técnicas de avaliação global de maneira que as previsões teóricas puderam ser verificadas. Por fim são apresentadas conclusões sobre o desempenho global do sistema e adicionados tópicos como sugestões para continuidade futura do trabalho. / The digital retinography and angiography are techniques to observe and capture images of the eye fundus that allows the diagnosis of several diseases. The improvements of digital fundus camera made possible by technological advances seen in recent decades have made possible innovative systemic changes, as the presented and discussed in this work. The main objective is to comparatively evaluate the spatial resolution of images captured with a configuration that uses only a monochrome sensor and a set of chromatic LEDs, with images generated by a sensor with integrated color filter. The proposal is supported by theoretical results that indicate a superior performance when using a monochrome sensor to get fundus images. To validate the new methodology, the system described was assembled and several retina pictures were taken. The whole process of imaging the eye fundus is described, including software procedures that had to be created as a consequence of the innovations. From the images captured, overall evaluation techniques have been applied, so that theoretical forecasts could be verified. Finally, conclusions are presented on the overall performance of the system and suggestions for topics for future work were added.
4

Proposta de inovação no sistema de aquisição de imagens aplicado em retinógrafos digitais / Proposal of innovation in the imaging system applied in digital fundus camera

Vieira, Flávio Pascoal 12 April 2013 (has links)
A retinografia e angiografia digital são técnicas de observação e captura de imagens do fundo do olho que permitem o diagnóstico de diversas patologias. O aperfeiçoamento dos retinógrafos digitais, viabilizado pelos avanços tecnológicos observados nas últimas décadas, tornou possíveis modificações sistêmicas inovadoras como a apresentada e discutida neste trabalho. O principal objetivo é avaliar comparativamente a resolução espacial de imagens captadas com uma configuração que utiliza apenas um sensor monocromático e um conjunto de LEDs cromáticos, com imagens geradas por um sensor com filtro cromático integrado. A proposta é suportada por resultados teóricos que indicam um desempenho superior do uso de sensores monocromáticos em retinografia. Para validação da nova metodologia o sistema descrito foi montado e várias fotos da retina foram capturadas. Todo o processo de imageamento do fundo do olho é descrito, incluindo rotinas de software que precisaram ser criadas em decorrência das inovações. A partir das imagens capturadas foram aplicadas técnicas de avaliação global de maneira que as previsões teóricas puderam ser verificadas. Por fim são apresentadas conclusões sobre o desempenho global do sistema e adicionados tópicos como sugestões para continuidade futura do trabalho. / The digital retinography and angiography are techniques to observe and capture images of the eye fundus that allows the diagnosis of several diseases. The improvements of digital fundus camera made possible by technological advances seen in recent decades have made possible innovative systemic changes, as the presented and discussed in this work. The main objective is to comparatively evaluate the spatial resolution of images captured with a configuration that uses only a monochrome sensor and a set of chromatic LEDs, with images generated by a sensor with integrated color filter. The proposal is supported by theoretical results that indicate a superior performance when using a monochrome sensor to get fundus images. To validate the new methodology, the system described was assembled and several retina pictures were taken. The whole process of imaging the eye fundus is described, including software procedures that had to be created as a consequence of the innovations. From the images captured, overall evaluation techniques have been applied, so that theoretical forecasts could be verified. Finally, conclusions are presented on the overall performance of the system and suggestions for topics for future work were added.
5

Sensor de frente de onda para uso oftalmológico / Wavefront sensor for ophthalmological use

Santos, Jesulino Bispo dos 16 April 2004 (has links)
Este trabalho descreve os passos envolvidos no desenvolvimento de um protótipo de aberroscópio para uso oftalmológico. Este instrumento faz incidir no fundo do olho humano um feixe luminoso de baixa potência e amostra, por meio do método de Hartmann, as frentes de onda da luz espalhada. A partir dos dados coletados, a forma das frentes de onda são reconstituídas e as aberrações eventualmente existentes no olho são calculadas e representadas por intermédio dos polinômios de Zernike. Aqui são expostos os fundamentos deste método, algumas das suas propriedades e limitações. Também é mostrada a caracterização funcional do protótipo desenvolvido, testando-o com elementos ópticos de propriedades conhecidas / This work describes the steps involved in the aberroscope prototype development for ophthalmological use. This instrument injects inside the human eye a low power light beam and sample, by Hartmann method, the wavefronts produced by ocular fundus light scattering. From collected data, the wavefront shape is reconstructed and the eye aberrations that eventually existent are calculated and adjusted by Zernike polynomials. Are discussed the method foundations, some of properties and limitations. Also the functional characterization of the developed prototype is shown, by testing it with optical elements of known properties
6

Sensor de frente de onda para uso oftalmológico / Wavefront sensor for ophthalmological use

Jesulino Bispo dos Santos 16 April 2004 (has links)
Este trabalho descreve os passos envolvidos no desenvolvimento de um protótipo de aberroscópio para uso oftalmológico. Este instrumento faz incidir no fundo do olho humano um feixe luminoso de baixa potência e amostra, por meio do método de Hartmann, as frentes de onda da luz espalhada. A partir dos dados coletados, a forma das frentes de onda são reconstituídas e as aberrações eventualmente existentes no olho são calculadas e representadas por intermédio dos polinômios de Zernike. Aqui são expostos os fundamentos deste método, algumas das suas propriedades e limitações. Também é mostrada a caracterização funcional do protótipo desenvolvido, testando-o com elementos ópticos de propriedades conhecidas / This work describes the steps involved in the aberroscope prototype development for ophthalmological use. This instrument injects inside the human eye a low power light beam and sample, by Hartmann method, the wavefronts produced by ocular fundus light scattering. From collected data, the wavefront shape is reconstructed and the eye aberrations that eventually existent are calculated and adjusted by Zernike polynomials. Are discussed the method foundations, some of properties and limitations. Also the functional characterization of the developed prototype is shown, by testing it with optical elements of known properties

Page generated in 0.0542 seconds