• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 20
  • 5
  • 4
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 56
  • 56
  • 18
  • 14
  • 12
  • 11
  • 11
  • 9
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Monitoring of Splanchnic Regional Perfusion : An Experimental Study of New Application and Validation

Koga, Itaru January 2003 (has links)
Systemic infection, major surgery, trauma and many other causes can lead to impaired organ function. Compensated shock is not detected by global hemodynamic and oxygen measurements, as they take no account for regional variations. Focus has therefore gradually turned from looking at systemic changes to selective investigations of regional blood flow and ischemia. This thesis presents a series of experiments evaluating new application and validation of various monitoring techniques. An experimental porcine model with anesthetized and invasively monitored animals was used. The circulatory interventions included endotoxin infusion (septic shock), aortic constriction and selective clamping of splanchnic arteries. The aim was to compare air with saline tonometry, to validate the intraperitoneal use of tonometry and to reexamine the use of endoluminal reflectance pulse oxymetry. To investigate the relative contributions of regional blood flow and detection of ischemia, measurements of hepatic venous oxygen saturation (ShvO2), lactate concentrations and PCO2 gap were used. Our findings support the use of air instead of saline as the preferred technique for tonometric measurements. With the intraperitoneal application of tonometry we gain more information on regional aspects of the splanchnic circulation, and it appears to be a reliable monitoring option for early detection of ischemia in the small intestine. Measurements of ShvO2 will give an overall reflection of the intestinal circulation. The sigmoid colonic pulse oximetry showed a non-linear response in relation to regional blood flow, and will therefore not be able to detect gradual changes in oxygen saturation. Determination of the regional to endtidal PCO2 gap might prove valuable for monitoring of the intestinal circulation. Because of sophisticated interactions between portal and hepatic arterial blood flow and hepatic compensation for regional ischemia, a combination of monitoring techniques might be needed. The results of this study will hopefully encourage clinical evaluation of intraperitoneal tonometry and endtidal PCO2 gap recordings for non-invasive, semi-continuous, trend monitoring of the splanchnic circulation.
52

Oxygénation des lits capillaires à la papille optique des patients sains et glaucomateux

Tran, Van Loc 01 1900 (has links)
Le glaucome représente la première cause de cécité irréversible à l’échelle mondiale. C’est une maladie neuro-dégénérative caractérisée traditionnellement par une pression intraoculaire (PIO) élevée, un dommage du nerf optique et un défaut du champ visuel correspondant. En fait, la PIO élevée constitue le facteur de risque central associé au développement du glaucome. Cependant, en dépit d’un contrôle adéquat de la PIO, la maladie continue à progresser chez certains patients. Cela montre qu’il existe d’autres facteurs impliqués dans la pathogenèse du glaucome. Des études récentes indiquent qu’un dérèglement de l’oxygène est associé à son développement. En utilisant une nouvelle technologie multi-spectrale capable de mesurer la saturation en oxygène (SaO2) dans les structures capillaires de la rétine, cette étude tentera de déterminer si un état d’oxygénation anormal pourrait se retrouver à la papille optique des patients souffrant de glaucome. Une meilleure compréhension du rôle de l’oxygène pourrait aider à améliorer le pronostic du glaucome. Les résultats de l’étude indiquent que le facteur de position (supérieure, temporale et inférieure de la papille optique) n’a aucun effet sur la mesure SaO2 ainsi que sa variabilité chez les patients normaux. La comparaison de la SaO2 entre les sujets normaux et glaucomateux ne montre pas de différence statistiquement significative. En conclusion, la SaO2 «normale» mesurée dans les yeux glaucomateux n'exclut pas nécessairement que l'hypoxie ne soit pas impliquée dans la pathogenèse. Au moment de l’étude, la PIO était bien contrôlée par des médicaments topiques, ce qui pourrait influencer l’oxygénation à la papille optique. / Glaucoma is the leading cause of irreversible blindness worldwide. Traditionally, open-angle glaucoma was defined as a neurodegenerative disease characterized by high intraocular pressure (IOP), progressive retinal cell death with subsequent visual field loss. Elevated IOP has been identified as one of the major risk factors for glaucomatous optic nerve damage. However, adequate IOP control cannot prevent progression of the disease in all patients suggesting that there are other factors involved in the pathogenesis of glaucoma. Recent studies suggest that hypoxia may contribute to the development of glaucoma. Using a new multi-spectral detection system of oxygen saturation (O2Sa), this study determined whether an abnormal state of oxygenation at the optic disc could be found in glaucoma patients. Knowledge about the influence of the oxygen in glaucoma may help to improve the pronostic of the disease. The results of the study indicate that the position factor (superior, temporal and inferior of the optic nerve head) has no effect on the measurement of O2Sa and its variability in normal patients. Comparing the O2Sa between normal subjects and glaucoma subjects shows no statistically significant difference. In conclusion, the «normal» O2Sa measured in glaucomatous eyes does not necessarily exclude that hypoxia is not involved in the pathogenesis of glaucoma because glaucoma patients were under treatment with topical drops that lowered IOP. These medicines could affect the oxygenation of the optic disc.
53

Hodnocení tepové frekvence a saturace krve kyslíkem pomocí chytrého telefonu / Heart rate and blood oxygen saturation estimation using smartphone

Jordánová, Ivana January 2018 (has links)
Heart rate, Oxygen saturation, HR, SpO2, MATLAB, smartphone, mobile phone, photopletysmogram, PPG
54

Role endotelinových receptorů typu A a B v modelu fokální ischemie u mláďat laboratorního potkana / The role of endothelin receptors type A and B in the model of focal cerebral ischemia in immature rats

Vondráková, Kateřina January 2014 (has links)
Hypoxic-ischemic insult is a most common form of perinatal brain damage that threatens a newborn's life and can leads to permanent neurological sequelae. However, detailed aspects of the cerebral ischemia in the immature brain stay unanswered. We decide to use the model of focal cerebral ischemia induced by intrahippocampal endothelin-1 (ET-1) in 12-days-old rats. The knowledge about consequences of ET-1 induced ischemia and the role of endothelin receptors (ETA and ETB) in ischemia-induced consequences in immature brain are poor at present. Agonists and selective antagonists of the ETA and ETB receptors were used to determine the role of these receptors in the development of ischemia, changes in regional blood flow and tissue oxygenation, local changes of biochemical parameters and acute neuronal death. Our results indicates, that activation of the ETA receptors causes a strong decrease of the blood flow, induced related hypoxia and subsequent neuronal degeneration, whereas activation of ETB receptors has likely modulatory role. Moreover, ischemia causes increase of excitatory amino acids concentration, whereas inhibitory amino acid, except taurine, decreased after ischemia. These facts provides new insights in a case of perinatal ischemia. This thesis demonstrates the wide range of different effects of...
55

Noninvasive Blood Flow and Oxygenation Measurements in Diseased Tissue

Rinehart, Benjamin S. 17 December 2021 (has links)
No description available.
56

Development and Testing of a Near-Infrared Spectroscopy Opioid Overdose Detection Device

Michael D Maclean (8795939) 12 October 2021 (has links)
Opioid overdose is a growing epidemic plaguing the United States. Overdose related death has risen from 16,849 in 1999 to 69,029 in 2018. Almost 7 out of 10 of these deaths were due to opioids with 47% being caused by fentanyl or other synthetic opioids. There is a strong need to reduce the amount of overdose-related deaths. Indirect methods should be a first priority, and include counseling and care. For some individuals, this treatment option is unavailable because the drug user may not have the desire or economic means to pursue it. In this case, a more direct preventative approach is needed. This paper presents a novel method of detecting poor peripheral oxygenation, a biomarker linked to opioid overdose. A wristwatch near-infrared spectroscopy device (NIRS) was developed. SPICE simulations were conducted to confirm proper operation of electrical systems. The device was fabricated on a printed circuit board and mounted to a 3D printed enclosure. Absorbance of green, red and infrared (IR) light were measured. Additionally, peripheral capillary oxygen saturation (SpO2) modulation index and changes in concentration of oxyhemoglobin and deoxyhemoglobin were calculated from raw data. A brachial occlusion test was performed to mimic the effects of opioid overdose on peripheral oxygenation. A statistically significant difference (p < 0.05) was observed between pre-occlusion and during-occlusion groups in two subjects for measurement of peak-to-peak values of green raw data, red raw data, IR raw data, oxyhemoglobin concentration change, and deoxyhemoglobin concentration change. Peak-to-peak was observed as a consistent indicator of poor peripheral oxygenation and could serve as a useful metric in the detection of opioid overdose.

Page generated in 0.1463 seconds