• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 65
  • 5
  • 4
  • 1
  • Tagged with
  • 76
  • 76
  • 64
  • 59
  • 38
  • 36
  • 31
  • 29
  • 28
  • 18
  • 17
  • 15
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo da produção de prótese removível em laboratórios da cidade de São Paulo" / Study of Removable Denture Production in laboratories of São Paulo city

Neves, Claudia Ferreira 15 September 2005 (has links)
O propósito deste trabalho foi analisar a produção de prótese removível em três laboratórios da cidade de São Paulo observando o perfil da população que recebeu este tratamento. A produção foi registrada diariamente, por meio de ensaios fotográficos padronizados, durante um mês de trabalho junto aos laboratórios. Foram enviados questionários para complementação de informações das técnicas e materiais utilizados pelos técnicos responsáveis. Da amostra de 367 próteses, 52% foram feitas para mulheres, e 33% para homens; não se notou diferenças estatisticamente significantes entre a quantidade de modelos nos arcos maxilares e mandibulares; segundo a classificação de Kennedy, a Classe I foi a mais freqüente principalmente para os arcos inferiores e, para os arcos superiores, a Classe III; o conector mais utilizado para o arco inferior foi a barra lingual e para o arco superior o tipo em forma de ferradura; com relação aos dentes remanescentes a média de dentes retidos para os arcos inferiores foi de 7,72 dentes, e para os arcos superiores foi de 7,54 dentes; a grande maioria de prótese confeccionada foi a de armação de cobalto-cromo, com grampo circuferencial, ou a barra; as próteses terapêuticas apresentaram uma porcentagem de 5,45% do total. / The aim of this work was to analyze the removable denture production in three dental laboratories, city of São Paulo, regarding to the population profile submitted to this treatment. The production was daily registered, through pattern photographs, during one month of work in each laboratory. Questionnaires were sent in order to obtain a complementation in technical and material information used by the responsible technicians. From the 367 dentures of the sample, 52 % were obtained from women and 33% from men; it was not observed significant statistical differences between the quantity of maxillary and mandibular models; according to Kennedy classification, the Class I was most frequent in inferior dental arches while the Class III was most frequent in superior dental arches; the most used connector was the lingual bar in inferior dental arches and the horseshoe type in superior dental arches; regarding the teeth remaining the mean values were 7.72 teeth for inferior dental arches and 7.54 for superior dental arches; the great majority of prosthesis was confectioned in chrome-cobalt with circumferential arm clasp or bar clasp; the therapeutic prosthesis presented a percentage of 5.45% from the total.
2

Comparative in vivo and in vitro studies on the biomechanics of maxillary partial dentures a methodological and experimental study /

Fernandes, Cláudio Pinheiro. January 1998 (has links)
Thesis (doctoral)--Lunds Universitet, Malmö, Sweden, 1998. / Added t.p. with thesis statement inserted. Includes bibliographical references.
3

Comparative in vivo and in vitro studies on the biomechanics of maxillary partial dentures a methodological and experimental study /

Fernandes, Cláudio Pinheiro. January 1998 (has links)
Thesis (doctoral)--Lunds Universitet, Malmö, Sweden, 1998. / Added t.p. with thesis statement inserted. Includes bibliographical references.
4

"Estudo da produção de prótese removível em laboratórios da cidade de São Paulo" / Study of Removable Denture Production in laboratories of São Paulo city

Claudia Ferreira Neves 15 September 2005 (has links)
O propósito deste trabalho foi analisar a produção de prótese removível em três laboratórios da cidade de São Paulo observando o perfil da população que recebeu este tratamento. A produção foi registrada diariamente, por meio de ensaios fotográficos padronizados, durante um mês de trabalho junto aos laboratórios. Foram enviados questionários para complementação de informações das técnicas e materiais utilizados pelos técnicos responsáveis. Da amostra de 367 próteses, 52% foram feitas para mulheres, e 33% para homens; não se notou diferenças estatisticamente significantes entre a quantidade de modelos nos arcos maxilares e mandibulares; segundo a classificação de Kennedy, a Classe I foi a mais freqüente principalmente para os arcos inferiores e, para os arcos superiores, a Classe III; o conector mais utilizado para o arco inferior foi a barra lingual e para o arco superior o tipo em forma de ferradura; com relação aos dentes remanescentes a média de dentes retidos para os arcos inferiores foi de 7,72 dentes, e para os arcos superiores foi de 7,54 dentes; a grande maioria de prótese confeccionada foi a de armação de cobalto-cromo, com grampo circuferencial, ou a barra; as próteses terapêuticas apresentaram uma porcentagem de 5,45% do total. / The aim of this work was to analyze the removable denture production in three dental laboratories, city of São Paulo, regarding to the population profile submitted to this treatment. The production was daily registered, through pattern photographs, during one month of work in each laboratory. Questionnaires were sent in order to obtain a complementation in technical and material information used by the responsible technicians. From the 367 dentures of the sample, 52 % were obtained from women and 33% from men; it was not observed significant statistical differences between the quantity of maxillary and mandibular models; according to Kennedy classification, the Class I was most frequent in inferior dental arches while the Class III was most frequent in superior dental arches; the most used connector was the lingual bar in inferior dental arches and the horseshoe type in superior dental arches; regarding the teeth remaining the mean values were 7.72 teeth for inferior dental arches and 7.54 for superior dental arches; the great majority of prosthesis was confectioned in chrome-cobalt with circumferential arm clasp or bar clasp; the therapeutic prosthesis presented a percentage of 5.45% from the total.
5

Influencia da reutilização de hidrocoloides reversiveis na alteração linear de modelos de revestimentos utilizados no processo de fundição de proteses parciais removiveis

Silva-Concilio, Lais Regiane da 12 November 2002 (has links)
Orientador: Celia Marisa Rizzatti Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T19:46:49Z (GMT). No. of bitstreams: 1 Silva-Concilio_LaisRegianeda_M.pdf: 2601283 bytes, checksum: e3d20b72a9e5b76acb85ff36d0a4bd45 (MD5) Previous issue date: 2002 / Resumo: O objetivo deste trabalho foi avaliar a alteração linear de modelos refratários obtidos a partir de moldes de hidrocolóide reversível (HR) de duas marcas comerciais (DUPLlCADOR VIPI® -Dental VIPI Ltda. e DUPLlCADOR K27® - Knebel Produtos Dentários Ltda.), submetidos a 15 ciclos de reutilização. Para isto, foi utilizado um modelo metálico com 4 marcações (A, B, C e D) que quando unidas, admitiam a mensuração linear das distâncias AB, BC, CD, DA, BD e AC. A partir deste modelo, foram confeccionados 10 modelos em gesso tipo IV, divididos aleatoriamente, para cada marca comercial de HR, em dois grupos com 5 modelos cada um (Grupo Controle). O HR foi fluidificado em forno de microondas de acordo com as instruções dos fabricantes e vertido no interior da mufla que continha o modelo de gesso. O molde era preenchido com revestimento de silicato de etila (REFRADEN® - Knebel Produtos Dentários Ltda.), e deste eram obtido os seus modelos refratários, respectivos a cada marca comercial. Esta metodologia foi repetida nos 15 ciclos de reutilização de cada HR. Os modelos refratários gerados pela 1a fluidificação, 5a, 10a e 15a reutilizações dos HRs, totalizando 40 modelos, foram mensurados em um microscópio mensurador (Mesuring Microscope STM - Olympus®). As médias foram submetidas à análise estatística pelos testes de Análise de Variância, Tukey e Dunnett, ao nível de 5% de significância. Os resultados evidenciaram que os modelos refratários obtidos pelo HR da marca VIPI® apresentaram alterações lineares em relação ao Grupo Controle, nas distâncias AB (1a fuidificação= -1,25% e 5a reutilização= -1,20%); AD (1a fluidificação=0,76%, 10a =0,65% e 15a =0,52% reutilizações); BD (1a fluidificação=0,58%). De acordo com os resultados obtidos, foi possível concluir que, mesmo havendo diferença significativa até 15 ciclos de reutilizações do HR, este fator não comprometeu à finalidade protética que se propõe o HR, gerando modelos de revestimento aceitáveis para ambas marcas comerciais investigadas / Abstract: The aim of this study was to evaluate linear alterations of refractories models obtained by 15 several cycles of heating using two reversible hydrocolloides (HR) (DUPLlCADOR VIPI® and DUPLlCADOR K27®).It was used a metallic master model with four defined points (A, B, C and D) which were linked to permit the measurement of the distances AB, BC, CD, DA, DB and AC. From this model, 10 stone models were obtained and separated in two groups randomized, according to the HR. After this, each model was duplicated with the same HR, according to the manufacturer. The mold was poured with ethyla silicate investment (REFRADEN® and so, the refractories models were obtained. By this methodology, each HR was used for 15 cycles. The respective refractories models obtained at the 1sth, 5th, 10th and 15thfluidification-geleification cycles were measured 3 times at a linear microscope (Mesuring Microscope STM - Olympus®. The averages of the distances were analyzed by ANOVA, Tukey and Dunnett testes (p<0.05).The results showed that the refractories models obtained by VIPI® HR had linear alterations when compared to stone models (control group) in distances AB (1st cycle= - 1.25% and 5th cycle=-1.20%); AD (1st cycle=0.76%, 10th=0.65% and 15th=0.52% cycles); BD (1st cycle=0.58%). According to the results, it can be concluded that although there is a significative difference after using HR for 15 cycles, it is irrelevant due to prosthetic use of HR when making investment model with both commercial types studied. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
6

Influencia da altura do remanescente coronario e do tipo de retenção intra-radicular na resistencia e modo de fratura de raizes bovinas restauradas com coroas totais

Resende, Cristina do Amparo 24 January 2005 (has links)
Orientador: Luis Roberto Marcondes Martins / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T03:54:21Z (GMT). No. of bitstreams: 1 Resende_CristinadoAmparo_M.pdf: 828266 bytes, checksum: 67ff65721ab9a2c7931bd0a2be4a3001 (MD5) Previous issue date: 2005 / Resumo: O objetivo deste estudo foi avaliar a influência da altura do remanescente coronário e de diferentes tipos de retenções intra-radiculares na resistência à fratura de raízes bovinas restauradas com coroas totais confeccionadas em resina composta laboratorial nas seguintes condições: ausência de remanescente coronário ou presença de um ou dois milímetros e cinco métodos de retenção intra-radicular. Cento e cinqüenta dentes bovinos foram selecionados padronizando-se as dimensões das raízes. As coroas foram seccionadas e as raízes remanescentes receberam tratamento endodôntico e foram divididas, aleatoriamente, em quinze experimentais (n=10): G1 - pino de fibra de vidro (FV) e 0 mm; G2 - FV e 1 mm; G3 - FV e 2 mm; G4 - pino pré-fabricado metálico (PM) e 0 mm; G5 - PM e 1 mm; G6 - PM e 2 mm; G7 - pino de fibra de carbono (FC) e 0 mm; G8 - FC e 1 mm; G9 - FC e 2 mm; G10 - núcleo metálico fundido (NMF) e 0 mm; G11 - NMF e 1 mm; G12 - NMF e 2 mm; G13 ¿ preenchimento do canal radicular com resina composta (RC) e 0 mm; G14 - RC e 1 mm; G15 - RC e 2 mm. As coroas totais foram cimentadas com cimento resinoso e as raízes foram fixadas em resina poliestirênica, simulando-se o ligamento periodontal com material de moldagem à base de poliéter. As amostras foram submetidas ao carregamento tangencial de compressão, sob um ângulo de 135o a 0,5 mm/min até ocorrer a fratura. Os resultados (ANOVA / Tukey a=0,05) demonstraram que na ausência de remanescente, o grupo RC apresentou os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com FC, FV e PM; o grupo restaurado com NMF apresentou os menores valores médios de resistência à fratura. Na presença de 1 mm de remanescente o grupo PM apresentou os maiores valores de resistência à fratura, não diferindo estatisticamente dos grupos restaurados com FV, NMF e RC e o grupo FC apresentou os menores valores médios. Na presença de 2 mm de remanescente, os diferentes tipos de retenções não promoveram diferenças entre os valores médios de resistência à fratura. Para os grupos restaurados com FV, FC e NMF, a altura do remanescente não influenciou nos resultados. Para os grupos PM, a altura de 1 mm proporcionou os maiores valores de resistência à fratura e o grupo com 2 mm de remanescente apresentou os menores valores. No grupo RC, a ausência de remanescente dental coronário promoveu os melhores resultados e o grupo com 1 mm de remanescente apresentou os piores resultados. A análise geral dos padrões de fratura demonstrou que 68% das fraturas atingiram os terços apical ou médio. Os grupos restaurados com pinos de fibra de vidro apresentaram os melhores padrões de fratura, enquanto os restaurados apenas com resina composta apresentaram os piores padrões de fratura / Abstract: The purpose of this study was to evaluate the influence of dental coronal structure height and different types of intraradicular retention on the fracture strength of bovine roots restored with total crowns made of laboratory composite resin under the following conditions: absence of dental coronal structure or presence of one or two millimeters, and five methods of intraradicular retention. One hundred fifty bovine teeth were chosen and the canal size was standardized. The crowns were sectioned and the canals were treated endodontically and the specimens distributed randomly into 15 experimental groups: G1 ¿ fiberglass post (FV) and 0 mm; G2 ¿ FV and 1 mm; G3 ¿ FV and 2 mm; G4 ¿ prefabricated metal post (PM) and 0 mm; G5 ¿ (PM) and 1 mm; G6 ¿ (PM) and 2 mm; G7 ¿ carbon fiber post (FC) and 0 mm; G8 ¿ (FC) and 1 mm; G9 ¿ (FC) 1 mm; G15 ¿ RC and 2 mm. Total crowns were luted with resin cement and the roots were fixed in resin blocks and artificial periodontal ligament was simulated with casting material made of polyether. The specimens were submitted to compressive strength test at 135o and 0.5 mm/min until fracture occurred. The results (ANOVA / Tukey a=0.05), showed that in absence of dental coronal structure, the group RC presented the most fracture strength values, not differing statistically from groups restored by FC, FV and PM, and the group restored by NMF presented the lowest mean values. In the presence of 1 mm, Group PM presented the highest fracture strength values, not differing statistically from groups restored by FV, NMF and RC, and the group restored by FC presented the lowest mean values. In the presence of 2 mm, the different types of intraradicular retentions did not cause differences among mean fracture strength values. In the groups restored by FV, FC and NMF, the dental coronal structure height had no influence on the results. In the PM group, the height of 1 mm, showed the highest and the group with 2 mm presented the lowest mean values. In the group RC the absence of dental coronal structure showed the best results and the group with 1 mm presented the worst results. The general fracture pattern analysis showed that 68% of fractures involved the gingival and apical thirds. The groups restored by FV showed the best fracture patterns, and the groups restored by RC, the worst / Mestrado / Dentística / Mestre em Clínica Odontológica
7

Avaliação de satisfação dos usuários e qualidade das Próteses Parcial Removível instaladas na clínica de graduação da FOUSP entre 2010-2014 / Satisfaction evaluation and quality of removable partial dentures in the FOUSP undergraduate clinic between 2010-2014

Camargo, Marcelli Soares de Souza 06 June 2016 (has links)
O objetivo deste trabalho foi avaliar a qualidade e satisfação das próteses parciais removíveis instaladas na clínica da graduação da disciplina de prótese removível no período de 2010-2014. Os pacientes que participaram da clínica nesse período foram contactados por telefone e convidados a participar da clínica de retorno da disciplina e ao mesmo tempo verificar a qualidade das próteses e a satisfação do paciente. Do total de 284 próteses instaladas nesse período, 50 foram avaliadas neste trabalho. Os pacientes que aceitaram participar da pesquisa preencheram 4 questionários: 1) TCLE, 2) Mini-mental; 3) GOHAI e 4) Anamnese da Prótese. Das próteses presentes no estudo classificaram-se em Perfeitas (sem queixa) e Problemáticas (com queixa). Após preenchido os questionários, relacionou-se a queixa principal com arco restaurado, análise da oclusão presente na prótese em função na boca, qualidade da sela, higienização da prótese e o momento em que a falha é decorrente. Como conclusão, teve-se que a queixa \"soltar sozinha\" foi a de maior destaque e está relacionada ao momento da falha pós- instalação. As próteses mal adaptadas estão relacionadas com uma qualidade de vida prejudicada e isto reforça que os retornos periódicos para controle da prótese são fundamentais para o sucesso clínico da prótese. / The objective of this study was to evaluate the quality and satisfaction of removable partial dentures installed in removable prosthesis undergraduate clinic in the 2010-2014 period. Patients attending the clinic during this period were contacted by telephone and invited to participate in the discipline of clinical and return at the same time check the quality of prosthetics and patient satisfaction. Of the total of 284 implants installed during this period, 50 were evaluated in this study. Patients who agreed to participate completed 4 questionnaires: 1) TCLE, 2) MiniMental, 3)GOHAI and 4) anamnesis of the prosthesis. Prostheses present in the study were classified in Optimal (without complaint) and Problematic (complaining). Thus, the complaint related to restored arch, occlusal analysis in the function of the prosthesis, saddle quality, denture cleaning and the time when the failure is due. In conclusion, it was that the complaint \"drop alone\" was the most prominent and is related to the time of after installation failure. Poorly adapted prostheses are associated with impaired quality of life and this reinforces that the periodic returns to the prosthesis control are fundamental for clinical success of the prosthesis.
8

"Estudo comparativo da resistência à infiltração que diferentes materiais resinosos utilizados na cimentação de retentores intra-radiculares oferecem à passagem de fluidos que atravessam a dentina" / Comparative study of the infiltration resistance that different resinous materials used in intra-radicular retainers foundation offer to the fluids passage that cross through the dentine.

Mukai, Marcio Katsuyoshi 01 September 2005 (has links)
O Objetivo deste estudo é avaliar in vitro, a resistência que diferentes materiais resinosos têm a passagem de fluidos que atravessam a dentina na ausência de cemento radicular. Foram utilizados 60 dentes humanos cedidos pelo banco de dentes da FOUSP. Os dentes foram submetidos a tratamento endodôntico segundo a técnica de Paiva e Antoniazzi e armazenados a uma temperatura de 37°C em umidade 100% por 24 horas para o preparo do retentor intra -radicular respeitando o limite apical de 4 mm. Os retentores intra-radiculares foram modelados com resina tipo Duralay e fundidos com liga de prata e cimentados com os seguintes materiais: Oxifosfato de Zinco (SS White), Enforce (Dentsply), Panavia F (Kuraray) e Rely X (3M) . Após a cimentação, delimitou-se uma janela na região cervical da raiz onde o cemento foi removido com uma broca diamantada, a parte externa da raiz foi impermeabilizada com cianocrilato de etila e esmalte cosmético para posterior imersão em uma solução de azul de metileno a 1% por 48 horas. Decorrido este período, a camada impermeabilizante foi removida, os dentes foram desgastados no sentido mésio distal e avaliados com o programa Imagelab. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes (p < 0,01) do Panavia F (Kuraray) em relação aos outros três materiais, demonstrando a superioridade desse material no que se refere à impermeabilização do sistema de canais radiculares. Podemos concluir que dentre os materiais avaliados o cimento Panavia F (Kuraray) apresentou diferença estatisticamente significante, tanto para no segmento cervical quanto terço médio. / This study objective is to evaluate in vitro, the resistance that different resinous materials have through the fluids passage cross through the dentine in the absence of radicular cementum. 60 human teeth given by FOUSP bank of teeth were used. The teeth were submitted to endodontic treatment according to Paiva's and Antoniazzi´s technique and stored in a temperature of 37°C in humidity 100% during 24 hours for the preparation of the intra-radicular retainer, respecting the 4 mm apical limit. The intra -radicular retainers were modeled with Duralay resin type and melted with silver league and cemented with the following materials: Zinc Oxiphosfate (SS White), Enforce (Dentsply), Panavia F (Kuraray) and Rely X (3M). After the foundation, a window was delimited in the root cervical area where the cementum was removed with a diamond drill. The external part of the root was made waterproof with etile cyanocrylate and cosmetic enamel for subsequent immersion in a 1% blue methylen solution for 48 hours. Elapsed this period, the waterproof layer was removed, the teeth were consumed in the mesio-distal direction and appraised with the Imagelab software. The impregnated area by the tracer agent of the in the film of the cements comparison, in the cervical and medium thirds, revealed significant statistical differences (p <0,01) of Panavia F (Kuraray) in relation to the other three materials, demonstrating the superiority of that material in relationship to the radicular chanal “waterproofing" system. It’s possible to conclude that among the appraised materials, the Panavia F (Kuraray) cement presented significant statistical difference, in the cervical segment as well as the medium third.
9

Estudo da resistência de quatro diferentes materiais utilizados na cimentação de pinos à infiltração lateral / Study of lateral infiltration resistance of four different materials used for posts cementing

Mukai, Marcio Katsuyoshi 12 August 2010 (has links)
A raspagem e o aplainamento radicular removem o cemento presente nesta área, o qual funcionaria como barreira de dentina contra a penetração de bactérias, toxinas e outros produtos vindos da superfície externa do dente. O objetivo deste estudo foi avaliar, in vitro, em dentes tratados endodonticamente, a resistência apresentada por diferentes materiais de cimentação na infiltração do azul de metileno, que poderia atravessar a dentina radicular, quando submetido a duas diferentes situações: a) raspagem e aplainamento do cemento radicular e b) remoção de cemento com pontas diamantadas. Para isso, utilizou-se 48 dentes humanos unirradiculares, cedidos pelo banco de dentes da FOUSP, tratados endodonticamente e preparados para receberem pinos. Estes foram modelados com resina acrílica para que, por meio de fundição, fossem obtidos os retentores intrarradiculares metálicos. Os dentes foram divididos em 4 grupos com 12 espécimes, e a cada um dos grupos, destinado um tipo de material diferente para a cimentação: Cimento de Zinco® (SS White, Rio de Janeiro, Rio de Janeiro, Brasil), Cimentos resinosos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos). Após esse procedimento, delimitaram-se duas janelas na região cervical da raiz, sendo que num dos lados o cemento foi removido com uma ponta diamantada e no lado oposto, com 40 golpes de cureta Gracey 5-6 (Neumar, São Paulo, São Paulo, Brasil) paralelos ao longo eixo do dente. Exceto nas regiões instrumentadas, o dente foi impermeabilizado externamente e exposto à solução de azul de metileno a 1% e pH 7,2 durante 48 horas. As amostras foram desgastadas no sentido do longo eixo até o maior diâmetro do pino e a área impregnada pelo corante foi digitalizada e mensurada com o programa Imagelab®. A comparação da área impregnada pelo agente traçador na película dos cimentos, nos terços cervical e médio, revelou diferenças estatisticamente significantes entre si (p < 0,05). No lado em que a dentina foi removida com broca, houve diferença estatisticamente significante quando os três materiais adesivos foram comparados com o Cimento de Zinco (SS White, Rio de Janeiro, Rio de Janeiro, Brasil). Na comparação entre os cimentos resinosos houve diferença estatisticamente significante (p<05) somente entre os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan) e Rely X U 100® (3M Dental, Seefeld, Alemanha) para o terço apical. Na superfície tratada com curetas periodontais, verificou-se diferença estatisticamente significante entre os grupos estudados (p < 0,05) apenas quando comparados o cimento Rely X U 100® (3M Dental, Seefeld, Alemanha) com Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) para o terço cervical. Concluiu-se que para o tratamento com ponta diamantada, que os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) têm comportamento semelhante para os terços cervical e médio, diferindo apenas no terço apical. Já para o tratamento com curetas periodontais, os cimentos Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Alemanha) e Rely X Luting 2® (3M Dental, Sant Paul, Estados Unidos) mostraram resultados similares para os terços médio e apical, diferindo apenas no terço cervical. / Scaling and root planning remove cementum present in this area, which would acts as a dentin barrier against penetration of bacterias, toxins and other products coming from the surface of the tooth. The objective of this study was to evaluate in vitro endodontically treated teeth, the resistance of different materials to methylene blue, which could cross the root dentin when submitted to two different situations: a) scaling and root planning b) removal of cementum with drills. It was used 48 human uniradicular teeth, assigned by FOUSPs teeth bank and were endodontically treated and prepared to receive pins. These were modeled with an acrylic resin in order to obtain the metallic intraradicular posts. The teeth were divided into four groups with twelve specimens. Each one of the groups received a different material for cementing: Cement of Zinc® (SS White, Rio de Janeiro, Rio de Janeiro, Brazil), Panavia F® Resin Cements (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States). After this procedure, it was delimited two windows in the cervical region of the root. One of the sides the cementum was removed with a diamond drill and on the other side, with 40 Gracey 5-6 curette strokes (Neumar, São Paulo, Brazil) parallel to the long axis of the tooth. Except on the instrumented regions, the tooth was externally sealed and exposed to a 1% methylen blue solution and pH 7.2 during 48 hours. The samples were scraped from the long axis until the largest post diameter. The impregnated area with the dye were scanned and measured with the Imagelab® program. The comparison between the impregnated area through the tracer agent on the cement film in the cervical and medium thirds revealed statistically significant differences (p<0,05). On the side where the dentin was removed with a drill, there was a statistically significant difference when the three adhesive materials were compared to the Zinc Cement (SS White, Rio de Janeiro, Rio de Janeiro, Brazil). In the comparison between the resin cements there was a statistically significant difference (p<0,05) only between the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan) and Rely X U 100® (3M Dental, Seefeld, Germany) for the apical third. On the surface treated with periodontal curettes, it was identified a meaningful statistical difference between the studied groups (p<0,05) only when compared the cements: Rely X U 100® (3M Dental, Seefeld, Germany) with Rely X Luting 2® (3M Dental, Sant Paul, United States) for the cervical third. The conclusion was that when the treatment uses a drill, the cements: Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) have similar behavior to the cervical and medium third. The unique difference comes from the apical third. On the other hand, the treatments using periodontal curettes, the cements Panavia F® (Kuraray, Kurashiki, Okayama, Japan), Rely X U 100® (3M Dental, Seefeld, Germany) and Rely X Luting 2® (3M Dental, Sant Paul, United States) resulted in similar results for the medium and apical thirds, only differing on the cervical third.
10

Efeito de soluções higienizadoras diárias em ligas de cobalto-cromo e resina acrílica termopolimerizável para prótese parcial removível. / Effect of denture cleansers on the properties of removable partial denture: in vitro study.

Felipucci, Daniela Nair Borges 09 October 2009 (has links)
A higienização das próteses removíveis é fundamental para a longevidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de higienizadores de imersão nas superfícies da liga metálica e resina acrílica termopolimerizável de Prótese Parcial Removível (PPR), simulando 180 dias. Discos (12 mm x 3 mm) foram confeccionados com ligas metálicas de cobalto-cromo para PPR: Vera PDI® (VP) e DeguDent® (DD). Cada disco metálico foi incluído em mufla previamente preparada por matrizes de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os espécimes (n= 5) foram imersos nas seguintes soluções: água destilada (grupo controle - AD), hipoclorito de sódio 0,05% (HS), Cepacol® (cloreto de cetilpiridínio 0,005% - CE), Periogard® (digluconato de clorexidina 0,12% - PE), Corega Tabs® (peróxido alcalino e enzima - CT), Polident® (peróxido alcalino e enzima - PO) e Medical Interporous Dentures® (ácido cítrico - MI). Foram realizadas análise da estabilidade de cor por meio de espectrocolorímetro, análise visual da presença de manchas no metal, análise da perda de massa em balança de alta precisão e análise da rugosidade por meio de rugosímetro. Como estudo complementar, foram realizadas análises quantitativas da liberação de íons (cobalto e cromo) em cada solução com espectrômetro de massas e análises ópticas e qualitativas com microscópio eletrônico de varredura (MEV) e espectrometria de energia dispersiva de Raios-X (EDS). Os resultados de rugosidade, alteração de cor e massa apresentaram distribuição normal e homogênea, tendo sido submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à rugosidade (Ra&micro;m), não houve diferença estatisticamente significante entre as soluções e ligas tanto para o metal quanto para a resina. Com relação à alteração de cor da resina acrílica termopolimerizável (&Delta;E), houve diferença estatisticamente significante entre as ligas, soluções e na interação liga x solução. As soluções AD, CE e PE propiciaram menores valores que as demais. A resina associada à DD apresentou maior alteração de cor do que quando associada à VP (1,06 ± 0,51 e 0,51 ± 0,28, respectivamente). Com relação à presença de manchas no metal, o HS propiciou manchamento em 100% dos espécimes. O grupo MI/DD propiciou em 60% e o MI/VP em 40% dos espécimes. Quando avaliada a alteração de massa (g), as soluções CT e MI propiciaram maiores valores. Entre as ligas, a VP apresentou maior perda de massa. Com relação à liberação de íons cobalto e cromo, a solução de HS e a MI propiciaram maior liberação e quando comparadas as ligas, VP apresentou maior liberação de íons. Com o MEV pôde-se verificar que houve corrosão generalizada com o HS e por pites com a MI. Concluiu-se que as soluções CE, PE e PO não apresentaram efeitos deletérios podendo ser auxiliares à escovação para higienização de PPR. / The hygiene care of the removable dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on the surfaces of the alloys and heat-polymerized acrylic resin for removable partial denture (RPD), simulating a period of 180 days. Circular specimens (12 mm x 3 mm) had been fabricated with cobalt-chromium alloys: Vera PDI&trade; (VP) and DeguDent&trade; (DD). The cast specimens were centered in the moulds previously prepared by matrices of teflon (38 mm x 18 mm x 4 mm) and the acrylic resin was inserted. The specimens (n= 5) had been immersed in the following solutions: distilled water (control - DW), sodium hypochlorite 0.05% (SH), Cepacol&trade; (cetilpiridinium chloride 0.005% - CE), Periogard&trade; (chlorexidine gluconate 0.12% - PE), Corega Tabs&trade; (alkaline peroxide and enzyme - CT), Polident&trade; (alkaline peroxide and enzyme - PO) and Medical Interporous Dentures&trade; (citric acid - MI). The color stability was analyzed using a colorimeter, and the presence of tarnishes on the metal was performed by a visual analysis. The weight loss was measured with a precision balance and the surface roughness was analyzed with a surf-test analyzer. As complementary analyzes a quantitative study of ions release (cobalt and chromium) using inductively mass spectrometry and optical and qualitative analyses with scanning electron microscopy (SEM) associated to dispersive energy spectrometry were performed. The results of roughness, color stability and weight loss presented normal and homogeneous distribution and were submitted to ANOVA (p &le; 0.05) and Tukey test. There was no significant difference among the solutions and between the alloys for both metal and resin roughness (Ra &micro;m). The acrylic resin color stability (&Delta;E) was analyzed and showed significant difference among the solutions, alloys and interaction. AD, CE and PE solutions presented the lowest values of color changes. The resin associated to DD presented higher color change than when associated with the VP (1.06 ± 0.51 and 0.51 ± 0.28, respectively). The HS caused tarnishes on 100% of specimens. The MI/DD group provided 60% and the MI/VP in 40% of specimens. When was analyzed the mass loss (g), the solutions CT and MI had the higher values. Between the alloys VP presented higher weight loss. HS and MI presented greater ionic release and between the alloys, VP presented greater release. With the SEM it was possible observe the presence of widespread corrosion in the HS group and pites corrosion in the MI group. It was concluded that CE, PE, CT and PO solutions had no deleterious effects on the compounds of RPD and may be indicate as auxiliaries to brushing in the RPD hygiene care.

Page generated in 0.0927 seconds