• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 6
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Estudo da produção de prótese removível em laboratórios da cidade de São Paulo" / Study of Removable Denture Production in laboratories of São Paulo city

Neves, Claudia Ferreira 15 September 2005 (has links)
O propósito deste trabalho foi analisar a produção de prótese removível em três laboratórios da cidade de São Paulo observando o perfil da população que recebeu este tratamento. A produção foi registrada diariamente, por meio de ensaios fotográficos padronizados, durante um mês de trabalho junto aos laboratórios. Foram enviados questionários para complementação de informações das técnicas e materiais utilizados pelos técnicos responsáveis. Da amostra de 367 próteses, 52% foram feitas para mulheres, e 33% para homens; não se notou diferenças estatisticamente significantes entre a quantidade de modelos nos arcos maxilares e mandibulares; segundo a classificação de Kennedy, a Classe I foi a mais freqüente principalmente para os arcos inferiores e, para os arcos superiores, a Classe III; o conector mais utilizado para o arco inferior foi a barra lingual e para o arco superior o tipo em forma de ferradura; com relação aos dentes remanescentes a média de dentes retidos para os arcos inferiores foi de 7,72 dentes, e para os arcos superiores foi de 7,54 dentes; a grande maioria de prótese confeccionada foi a de armação de cobalto-cromo, com grampo circuferencial, ou a barra; as próteses terapêuticas apresentaram uma porcentagem de 5,45% do total. / The aim of this work was to analyze the removable denture production in three dental laboratories, city of São Paulo, regarding to the population profile submitted to this treatment. The production was daily registered, through pattern photographs, during one month of work in each laboratory. Questionnaires were sent in order to obtain a complementation in technical and material information used by the responsible technicians. From the 367 dentures of the sample, 52 % were obtained from women and 33% from men; it was not observed significant statistical differences between the quantity of maxillary and mandibular models; according to Kennedy classification, the Class I was most frequent in inferior dental arches while the Class III was most frequent in superior dental arches; the most used connector was the lingual bar in inferior dental arches and the horseshoe type in superior dental arches; regarding the teeth remaining the mean values were 7.72 teeth for inferior dental arches and 7.54 for superior dental arches; the great majority of prosthesis was confectioned in chrome-cobalt with circumferential arm clasp or bar clasp; the therapeutic prosthesis presented a percentage of 5.45% from the total.
2

"Estudo da produção de prótese removível em laboratórios da cidade de São Paulo" / Study of Removable Denture Production in laboratories of São Paulo city

Claudia Ferreira Neves 15 September 2005 (has links)
O propósito deste trabalho foi analisar a produção de prótese removível em três laboratórios da cidade de São Paulo observando o perfil da população que recebeu este tratamento. A produção foi registrada diariamente, por meio de ensaios fotográficos padronizados, durante um mês de trabalho junto aos laboratórios. Foram enviados questionários para complementação de informações das técnicas e materiais utilizados pelos técnicos responsáveis. Da amostra de 367 próteses, 52% foram feitas para mulheres, e 33% para homens; não se notou diferenças estatisticamente significantes entre a quantidade de modelos nos arcos maxilares e mandibulares; segundo a classificação de Kennedy, a Classe I foi a mais freqüente principalmente para os arcos inferiores e, para os arcos superiores, a Classe III; o conector mais utilizado para o arco inferior foi a barra lingual e para o arco superior o tipo em forma de ferradura; com relação aos dentes remanescentes a média de dentes retidos para os arcos inferiores foi de 7,72 dentes, e para os arcos superiores foi de 7,54 dentes; a grande maioria de prótese confeccionada foi a de armação de cobalto-cromo, com grampo circuferencial, ou a barra; as próteses terapêuticas apresentaram uma porcentagem de 5,45% do total. / The aim of this work was to analyze the removable denture production in three dental laboratories, city of São Paulo, regarding to the population profile submitted to this treatment. The production was daily registered, through pattern photographs, during one month of work in each laboratory. Questionnaires were sent in order to obtain a complementation in technical and material information used by the responsible technicians. From the 367 dentures of the sample, 52 % were obtained from women and 33% from men; it was not observed significant statistical differences between the quantity of maxillary and mandibular models; according to Kennedy classification, the Class I was most frequent in inferior dental arches while the Class III was most frequent in superior dental arches; the most used connector was the lingual bar in inferior dental arches and the horseshoe type in superior dental arches; regarding the teeth remaining the mean values were 7.72 teeth for inferior dental arches and 7.54 for superior dental arches; the great majority of prosthesis was confectioned in chrome-cobalt with circumferential arm clasp or bar clasp; the therapeutic prosthesis presented a percentage of 5.45% from the total.
3

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Costa, Edna Goncalves da 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
4

Análise da transmissão e distribuição de tensões aplicadas em próteses totais convencionais reembasadas com diferentes espessuras de forrador macio / Analysis of Transmission and Distribution Voltages Applied to the Conventional Denture relined with a liner Soft

Lima, Juliana Bisinotto Gomes 08 July 2011 (has links)
Os materiais resilientes ou macios para reembasamento de base de próteses são utilizados na clínica odontológica com a finalidade de proporcionar maior conforto e eficiência mastigatória aos pacientes que utilizam próteses removíveis totais e que por situações específicas não suportam uma prótese removível total convencional com base rígida. Atualmente é muito utilizado nas próteses removíveis transicionais, para minimizar as pressões sobre implantes que se encontram na fase de osseointegração, além de proporcionar ausência de lesões traumáticas e condicionamento tecidual durante o período pós-cirúrgico; em casos de rebordo alveolar atrofiado; irritação crônica superficial possivelmente devido à pressão do forame mentoniano; rebordo em lâmina de faca; após radiação terapêutica dissipando as forças oclusais, entre outras. Assim, é objetivo deste estudo analisar por meio do método de elementos finitos tridimensional a distribuição de tensões aplicadas na prótese removível total reembasada com forradores macios em diferentes espessuras e consequente transmissão a mucosa e ao rebordo, definindo a espessura ideal de material reembasador. Os corpos-de-prova constituirão-se em modelos projetados de mandíbula desdentada com uma prótese total apoiada sobre o rebordo. São 6 modelos: modelo 1: prótese removível total apoiada diretamente sobre o rebordo sem material reembasador (caso controle); modelo 2: prótese removível total reembasada com 0,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 3: prótese removível total reembasada com 1mm de espessura de material reembasador apoiada sobre o rebordo; modelo 4: prótese removível total reembasada com 1,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 5: prótese removível total reembasada com 2,0mm de espessura de material reembasador apoiada sobre o rebordo; modelo 6: prótese removível total reembasada com 2,5mm de espessura de material reembasador apoiada sobre o rebordo. Uma força de 60N foi aplicada ao longo eixo dos dentes das próteses, sendo de mesma intensidade bilateralmente e simultaneamente. Após a execução dos teste e análise dos resultados verifica-se que a adição de apenas 0,5 mm de material reembasador (modelo 2), diminuiu em 10% o pico de tensão, ocorrendo diminuições menores com o aumento gradual da espessura de material reembasador. Dentro das características do presente trabalho, a diminuição dos picos são menores do que 1% entre os modelos 4 e 5, sugerindo que para mandíbulas com boa adaptação da prótese, superfície óssea lisa, sem espículas, nichos dentários ou outros fatores semelhantes, não é significativo uma espessura maior do que 1,5 mm de material reembasador . Um resultado que sai desse padrão se refere ao modelos 5 e 6, onde o aumento de 2 para 2,5 mm de espessura do material reembasador promoveu um aumento nos picos de tensão. Diante das características in vitro deste estudo conclui-se que uma espessura de 2mm de material reembasador é o suficiente para amortecer as forças mastigatórias. No presente estudo, espessura maior que 2mm promoveu tensões à mucosa e ao rebordo. / The soft or resilient materials for relining denture base are used in clinical dentistry in order to provide greater comfort and chewing efficiency of patients which use removable dentures for total and specific situations as they does not tolerate a removable prosthesis with total conventional rigid base. Currently it is widely used in transitional dentures, to minimize the pressures on implants in process of osseointegration, while providing no traumatic injuries and conditioning tissue during the postoperative period, in cases of atrophic alveolar ridge; superficial chronic irritation possibly due to pressure from the mental foramen, edging knife blade, and after radiation therapy dissipating occlusal forces. The aim of this study is to analyze through the three-dimensional finite element stress distribution applied in full removable denture rebased with soft liners in different thicknesses and consequent transmission to the mucosa and the edge, setting the ideal thickness of relining. The samples used in test form in models designed for edentulous mandible with a denture resting on the edge. There are 6 models: Model 1: Full removable denture supported directly on the alveolar ridge without relining (case control), Model 2: Full removable denture rebased with 0.5 mm thick relining resting on the alveolar ridge; Model 3: total removable prosthesis rebased with 1mm thickness relining resting on the alveolar ridge; Model 4: Full removable denture rebased with 1.5 mm thick relining resting on the alveolar ridge; Model 5: Full removable denture rebased with 2.0 mm thick relining resting on the alveolar ridge; Model 6: Full removable denture rebased with 2.5 mm thick supported on relining the alveolar ridge. A force of 60N was applied to the long axis of the tooth prosthesis, with the same intensity bilaterally and simultaneously. After execution of test and analysis of results shows that the addition of only 0.5 mm relining (model 2), down 10% peak tension, smaller decreases occurred with the gradual increase of the thickness of relining. Among the features of the present study, the decrease of the peaks are less than 1% between sections 4 and 5, suggesting that mandibles with good adaptation to the prosthesis, bone surface smooth, without spines, teeth or niches other similar factors, it is not a significant thickness greater than 1.5 mm relining. A result that comes out of this pattern refers to models 5 and 6, where the increase of 2 to 2.5 mm thick relining promoted an increase in spikes. The features of this in vitro study concluded that a thickness of 2mm relining is enough to absorb chewing forces. In this study, thickness greater than 2mm must transfer tension to the mucosa and alveolar ridge.
5

Análise da transmissão e distribuição de tensões aplicadas em próteses totais convencionais reembasadas com diferentes espessuras de forrador macio / Analysis of Transmission and Distribution Voltages Applied to the Conventional Denture relined with a liner Soft

Juliana Bisinotto Gomes Lima 08 July 2011 (has links)
Os materiais resilientes ou macios para reembasamento de base de próteses são utilizados na clínica odontológica com a finalidade de proporcionar maior conforto e eficiência mastigatória aos pacientes que utilizam próteses removíveis totais e que por situações específicas não suportam uma prótese removível total convencional com base rígida. Atualmente é muito utilizado nas próteses removíveis transicionais, para minimizar as pressões sobre implantes que se encontram na fase de osseointegração, além de proporcionar ausência de lesões traumáticas e condicionamento tecidual durante o período pós-cirúrgico; em casos de rebordo alveolar atrofiado; irritação crônica superficial possivelmente devido à pressão do forame mentoniano; rebordo em lâmina de faca; após radiação terapêutica dissipando as forças oclusais, entre outras. Assim, é objetivo deste estudo analisar por meio do método de elementos finitos tridimensional a distribuição de tensões aplicadas na prótese removível total reembasada com forradores macios em diferentes espessuras e consequente transmissão a mucosa e ao rebordo, definindo a espessura ideal de material reembasador. Os corpos-de-prova constituirão-se em modelos projetados de mandíbula desdentada com uma prótese total apoiada sobre o rebordo. São 6 modelos: modelo 1: prótese removível total apoiada diretamente sobre o rebordo sem material reembasador (caso controle); modelo 2: prótese removível total reembasada com 0,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 3: prótese removível total reembasada com 1mm de espessura de material reembasador apoiada sobre o rebordo; modelo 4: prótese removível total reembasada com 1,5mm de espessura de material reembasador apoiada sobre o rebordo; modelo 5: prótese removível total reembasada com 2,0mm de espessura de material reembasador apoiada sobre o rebordo; modelo 6: prótese removível total reembasada com 2,5mm de espessura de material reembasador apoiada sobre o rebordo. Uma força de 60N foi aplicada ao longo eixo dos dentes das próteses, sendo de mesma intensidade bilateralmente e simultaneamente. Após a execução dos teste e análise dos resultados verifica-se que a adição de apenas 0,5 mm de material reembasador (modelo 2), diminuiu em 10% o pico de tensão, ocorrendo diminuições menores com o aumento gradual da espessura de material reembasador. Dentro das características do presente trabalho, a diminuição dos picos são menores do que 1% entre os modelos 4 e 5, sugerindo que para mandíbulas com boa adaptação da prótese, superfície óssea lisa, sem espículas, nichos dentários ou outros fatores semelhantes, não é significativo uma espessura maior do que 1,5 mm de material reembasador . Um resultado que sai desse padrão se refere ao modelos 5 e 6, onde o aumento de 2 para 2,5 mm de espessura do material reembasador promoveu um aumento nos picos de tensão. Diante das características in vitro deste estudo conclui-se que uma espessura de 2mm de material reembasador é o suficiente para amortecer as forças mastigatórias. No presente estudo, espessura maior que 2mm promoveu tensões à mucosa e ao rebordo. / The soft or resilient materials for relining denture base are used in clinical dentistry in order to provide greater comfort and chewing efficiency of patients which use removable dentures for total and specific situations as they does not tolerate a removable prosthesis with total conventional rigid base. Currently it is widely used in transitional dentures, to minimize the pressures on implants in process of osseointegration, while providing no traumatic injuries and conditioning tissue during the postoperative period, in cases of atrophic alveolar ridge; superficial chronic irritation possibly due to pressure from the mental foramen, edging knife blade, and after radiation therapy dissipating occlusal forces. The aim of this study is to analyze through the three-dimensional finite element stress distribution applied in full removable denture rebased with soft liners in different thicknesses and consequent transmission to the mucosa and the edge, setting the ideal thickness of relining. The samples used in test form in models designed for edentulous mandible with a denture resting on the edge. There are 6 models: Model 1: Full removable denture supported directly on the alveolar ridge without relining (case control), Model 2: Full removable denture rebased with 0.5 mm thick relining resting on the alveolar ridge; Model 3: total removable prosthesis rebased with 1mm thickness relining resting on the alveolar ridge; Model 4: Full removable denture rebased with 1.5 mm thick relining resting on the alveolar ridge; Model 5: Full removable denture rebased with 2.0 mm thick relining resting on the alveolar ridge; Model 6: Full removable denture rebased with 2.5 mm thick supported on relining the alveolar ridge. A force of 60N was applied to the long axis of the tooth prosthesis, with the same intensity bilaterally and simultaneously. After execution of test and analysis of results shows that the addition of only 0.5 mm relining (model 2), down 10% peak tension, smaller decreases occurred with the gradual increase of the thickness of relining. Among the features of the present study, the decrease of the peaks are less than 1% between sections 4 and 5, suggesting that mandibles with good adaptation to the prosthesis, bone surface smooth, without spines, teeth or niches other similar factors, it is not a significant thickness greater than 1.5 mm relining. A result that comes out of this pattern refers to models 5 and 6, where the increase of 2 to 2.5 mm thick relining promoted an increase in spikes. The features of this in vitro study concluded that a thickness of 2mm relining is enough to absorb chewing forces. In this study, thickness greater than 2mm must transfer tension to the mucosa and alveolar ridge.
6

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Edna Goncalves da Costa 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
7

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Davi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
8

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Letícia Resende Davi 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.

Page generated in 0.0954 seconds