• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Costa, Edna Goncalves da 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
2

"Avaliação da força de tração da sela modificada para prótese" / Evaluation of traction force in modified saddle for prosthesis.

Edna Goncalves da Costa 11 August 2005 (has links)
Do planejamento à execução da prótese mucosa-dento-suportada, a literatura apresenta trabalhos que aponta m as dificuldades do desempenho de uma prótese que se relaciona com tecidos de comportamentos distintos, dente e fibromucosa. Estes trabalhos abordam os problemas biomecânicos e os prejuízos que sofrem o osso e os dentes, sob pressão, durante a mastigação, bem como as dificuldades de distribuição das cargas sobre os tecidos bucais no movimento ocluso-gengival. Porém, essa prótese também sofre forças de tração, por diversas situações clínicas, as quais levam a sela a se deslocar da fibromucosa num movimento gêngivo-oclusal. O objeto desta pesquisa foi desenvolver e testar, em laboratório, um método que possibilitasse à prótese mucosa-dento-suportada dispor de maior retenção na região da fibromucosa, reduzindo o movimento gêngivo-oclusal, e conferindo maior estabilidade à prótese e conforto ao paciente. Para realizar o experimento , foi construída uma base acrílica modificada, correspondente à sela da prótese, com uma canaleta na região que contata a fibromucosa. Esta canaleta foi preenchida com reembasador macio para prótese, à base de silicone. Em seguida, a base foi reembasada no modelo resiliente, especialmente construído para simular a fibromucosa. Uma haste metálica foi fixada em suas extremidades, sendo uma à base acrílica, e a outra extremidade fixada ao mandril do equipamento utilizado para o tracionamento (Versa-Test). Estando a base posicionada sobre o modelo, foram realizados os movimentos de pressão e de tração. A avaliação dos testes foi realizada na base acrílica convencional (sem canaleta) e na base acrílica modificada, cujos valores foram registrados em newton. As bases acrílicas sobre os modelos eram imersas em óleo vegetal, devido ao necessário meio viscoso, com tensão superficial, possibilitando os fenômenos de adesão. Os resultados demonstraram que, na presença de silicone, foi necessária força de tração maior e estatisticamente significante para remover a base do modelo, em relação à base sem silicone. / From the planning to the execution of the tissue-dento-supported prosthesis, the literature presents a range of works standing out the difficulties related to the prosthesis performance when facing distinctive tissues, tooth and fibromucous. These works approach the biomechanical problems and the damages suffered by osseous tissues and teeth under pressure, during the mastication, as well as the difficulties of distribution of the loads on oral tissues in the oclusal-gengival movements. However, this prosthesis also suffers traction forces, in several clinical situations, leading the saddle to move of the fibromucous in a gengival-occlusal movement. The aim of this research was to develop and to test, in a laboratory, a method to improve the tissue-dento-supported prosthesis retention in the fibromucous area reducing the gengival-occlusal movement and allowing a larger stability to the prosthesis and comfort to the patient. In order to accomplish the experiment, a modified acrylic base was confectioned, corresponding to the saddle of the prosthesis and constituted by a small channel in the fibromucous contact area. This channel was filled out with soft reliner for prosthesis, silicon composed. Afterwards, the base was rebased in the resilient model, especially confectioned to simulate the fibromucous. A metallic stem was fixed in two extremities, being one to the acrylic base, and other extremity fixed to the equipment arbor used for the traction (Versa-Test). With the base positioned on the model, the pressure movements and traction were accomplished. The evaluation of the tests was accomplished in the conventional acrylic base (without channel) and in the modified acrylic base, whose values were registered in Newton. The acrylic bases on the models were immersed in the vegetable oil, due to the necessary viscous condition, with superficial tension, making possible the adhesion phenomena. The results demonstrated that in the presence of silicon was necessary a larger and statistically significant traction force to remove the base of the model in relation to the base without silicon.
3

\"Análise fotoelástica das estruturas de suporte de próteses totais com base acrílica e resiliente\" / Photoelastic analysis under support structures of full dentures with acrylic and resilient base

Eduardo, Daniel de Paula 28 September 2006 (has links)
O objetivo dessa pesquisa foi avaliar, com o auxilio do método fotoelástico, o comportamento das tensões sobre as estruturas de suporte da prótese total mandibular, nas seguintes condições: 1. Prótese total com base confeccionada de forma convencional com resina acrílica; 2.Prótese total com base de resina acrílica e uma camada de material resiliente à base de silicone. Para o experimento foram confeccionadas 4 próteses totais, sendo uma com base de resina acrílica e 3 com bases de resina acrílica e material resiliente, com espessuras de 1mm, 2mm e 3mm. As 4 próteses, mais o modelo fotoelástico, constituíram os corpos de prova denominados: CPO (base de resina ); CP1; CP2 e CP3 (bases de resina e material resiliente). As condições de carregamento foram feitas com 0,5; 1,0; 1,5 e 2,0 bars, nesta seqüência, para cada corpo de prova. A seqüência de ensaios mostrou um comportamento de distribuição de tensões menos abrangente para o corpo de prova de base acrílica CP0, com as tensões concentradas na crista do rebordo e em pontos mais localizados na extensão da área basal, enquanto que os corpos de prova com material resiliente, CP1, CP2 e CP3, mostraram maior abrangência na distribuição das tensões para modelo, com franjas fotoelásticas mais extensas, à medida que a camada resiliente era mais espessa. Observou-se ainda, que com o aumento da espessura da camada resiliente, houve uma redução na largura e na intensidade das franjas, realizada de maneira mais uniforme e ampla, gerando intensidades menores e menos concentradas. As conclusões a que se chegou foram: 1. O corpo de prova de base acrílica CP0, apresentou concentração de tensões na crista do rebordo e em alguns pontos mais localizados da extensão da área basal do modelo fotoelástico, para todas as condições de carregamento; 2. Os corpos de prova com resina acrílica e material resiliente, CP1, CP2 e CP3 promoveram uma distribuição de tensões mais abrangentes no modelo fotoelástico; 3. O CP2 foi o que apresentou maior alteração na intensidade das tensões, na seqüência de imagens de 0,0 de carga até o carregamento máximo de 2,0 bars. O comportamento apresentado pelo CP1, sob todas as condições de carregamento e sob todos os aspectos avaliados, parece ser o mais recomendável para bases de próteses totais, compostas de resina acrílica e material resiliente à base de silicone. / The objective of this study was to evaluate the stress distribution under support structures of full dentures with acrylic and resilient base. The methodology used was the photoelastic analysis in four different conditions, full denture with acrylic base and full denture with acrylic and resilient base with different thickness (1mm, 2mm and 3mm). Like this a dry human skull was reproduced in photoelastic resin material and its lower dental arch was shaped in order to simulate an edentulous arch. In this way, four dentures were prepared and the load tests were done. The load distribution along the lower jaw was assessed by photoelastic stress analysis and showed that in denture with conventional acrylic base the loads were more concentrated and located in some areas whereas in dentures with conventional acrylic base and resilient base the loads were more uniformly distributed. The results and observed aspects suggested that the better thickness for denture resilient liners considering the stress distribution is 1mm although the 2mm and 3mm are also good to distribute the loads more uniformly than the acrylic hard base.
4

\"Análise fotoelástica das estruturas de suporte de próteses totais com base acrílica e resiliente\" / Photoelastic analysis under support structures of full dentures with acrylic and resilient base

Daniel de Paula Eduardo 28 September 2006 (has links)
O objetivo dessa pesquisa foi avaliar, com o auxilio do método fotoelástico, o comportamento das tensões sobre as estruturas de suporte da prótese total mandibular, nas seguintes condições: 1. Prótese total com base confeccionada de forma convencional com resina acrílica; 2.Prótese total com base de resina acrílica e uma camada de material resiliente à base de silicone. Para o experimento foram confeccionadas 4 próteses totais, sendo uma com base de resina acrílica e 3 com bases de resina acrílica e material resiliente, com espessuras de 1mm, 2mm e 3mm. As 4 próteses, mais o modelo fotoelástico, constituíram os corpos de prova denominados: CPO (base de resina ); CP1; CP2 e CP3 (bases de resina e material resiliente). As condições de carregamento foram feitas com 0,5; 1,0; 1,5 e 2,0 bars, nesta seqüência, para cada corpo de prova. A seqüência de ensaios mostrou um comportamento de distribuição de tensões menos abrangente para o corpo de prova de base acrílica CP0, com as tensões concentradas na crista do rebordo e em pontos mais localizados na extensão da área basal, enquanto que os corpos de prova com material resiliente, CP1, CP2 e CP3, mostraram maior abrangência na distribuição das tensões para modelo, com franjas fotoelásticas mais extensas, à medida que a camada resiliente era mais espessa. Observou-se ainda, que com o aumento da espessura da camada resiliente, houve uma redução na largura e na intensidade das franjas, realizada de maneira mais uniforme e ampla, gerando intensidades menores e menos concentradas. As conclusões a que se chegou foram: 1. O corpo de prova de base acrílica CP0, apresentou concentração de tensões na crista do rebordo e em alguns pontos mais localizados da extensão da área basal do modelo fotoelástico, para todas as condições de carregamento; 2. Os corpos de prova com resina acrílica e material resiliente, CP1, CP2 e CP3 promoveram uma distribuição de tensões mais abrangentes no modelo fotoelástico; 3. O CP2 foi o que apresentou maior alteração na intensidade das tensões, na seqüência de imagens de 0,0 de carga até o carregamento máximo de 2,0 bars. O comportamento apresentado pelo CP1, sob todas as condições de carregamento e sob todos os aspectos avaliados, parece ser o mais recomendável para bases de próteses totais, compostas de resina acrílica e material resiliente à base de silicone. / The objective of this study was to evaluate the stress distribution under support structures of full dentures with acrylic and resilient base. The methodology used was the photoelastic analysis in four different conditions, full denture with acrylic base and full denture with acrylic and resilient base with different thickness (1mm, 2mm and 3mm). Like this a dry human skull was reproduced in photoelastic resin material and its lower dental arch was shaped in order to simulate an edentulous arch. In this way, four dentures were prepared and the load tests were done. The load distribution along the lower jaw was assessed by photoelastic stress analysis and showed that in denture with conventional acrylic base the loads were more concentrated and located in some areas whereas in dentures with conventional acrylic base and resilient base the loads were more uniformly distributed. The results and observed aspects suggested that the better thickness for denture resilient liners considering the stress distribution is 1mm although the 2mm and 3mm are also good to distribute the loads more uniformly than the acrylic hard base.

Page generated in 0.0862 seconds