• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • Tagged with
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de tres metodos radiograficos - periapical, panoramico e sistema digital - no diagnostico de lesões apicais produzidas artificialmente

Santos, Julio Cesar Bento dos 06 February 1999 (has links)
Orientador: Solange Maria Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T12:46:37Z (GMT). No. of bitstreams: 1 Santos_JulioCesarBentodos_M.pdf: 7612034 bytes, checksum: 606a68f5cabb358d723b7501b7c58c5b (MD5) Previous issue date: 1999 / Resumo: O presente estudo teve por finalidade avaliar três métodos radiográficos, radiografia periapical, radiografia panorâmica e sistema digital, no diagnóstico de lesões apicais produzidas artificialmente em mandíbulas maceradas. E se o tamanho das lesões interferem no diagnóstico radiográfico. Para tanto, as lesões apicais foram produzidas utilizando-se brocas esféricas com diâmetros diferentes, permitindo assim que o diâmetro das lesões sofresse alteração em tamanho conforme a broca utilizada. Assim, o estudo foi dividido em 04 fases: fase inicial ou 1, caracterizada pela ausência de lesão; fase 2, caracterizada pela lesão produzida com a broca 6 com medida da ponta ativa de 1,8mm; fase 3, caracterizada pela lesão produzida com a broca 8 com medida da ponta ativa de 2,3mm; fase 4, caracterizada pela lesão produzida com a broca 10 com medida da ponta ativa de 2,7mm; e fase cortical ou 5, quando a lesão atingia as corticais ósseas. Todas as fases foram, realizadas em 04 regiões da mandíbula: incisivo, canino, pré-molares e molares. As radiografias foram obtidas após cada fase e, posteriormente, foram analisadas por 04 radiologistas. Houve diferença estatisticamente significante na fase broca 6 (R) nos incisivos a favor do sistema digital. O mesmo ocorreu na fase cortical (LI) na região de pré-molares. Na região dos molares houve uma diferença etatisticamente significante na fase broca 10 (D) para a radiografia panorâmica e na fase cortical esta técnica foi a menos eficaz. Nas demais fases e regiões não houve uma diferença estatisticamente significante / Abstract: The aim of this study was to evaluate three radiographys techniques: periapical radiography, panoramic and digital radiography, about diagnostic accuracy of artificially produced bony lesions in human jaw dry. The periapical diseases were done using burs numbers 6, 8 and 10 thus allowing the lesions diameter to incresing according to burs size. Therefore, the study was dividided in four phases: phase 1 without periapical disease, phase 2 periapical disease made by bur number 6, phase 3 periapical disease made by bur number 8, phase 4 periapical disease made by bur number 10 and phase 5 periapical disease touchs junction area of the cortex. The phases were in four regions in the jaw, anterior, canine, premolar and molar. The radiographies were evaluated by four oral radiologists observers. The results showed that in the anterior region there was a significant statistically difference only at phase 2, that is the lesion was produced with bur 6, the digital radiography was more successfull and it was also observed in the premolar region in the cortical phase. In the molar region there was a false true result during the inicial phase, without lesion. During phase 4 (burn 10 ) and cortical phase there was a statistically significant difference in favor of the panoramic radiography / Mestrado / Radiologia / Mestre em Odontologia
2

Aplicação de técnicas de processamento de imagens para auxílio na detecção de fraturas radiculares verticais em radiografias periapicais digitais / Application of image processing techniques to assist detection of vertical root fractures in digital periapical radiographs

Soares, Lucas Exposto 26 February 2019 (has links)
Fraturas radiculares verticais (FRV) são fraturas longitudinais que acontecem na raiz dos dentes. O diagnóstico clínico da FRV é um desafio, já que os pacientes não apresentam sinais e sintomas patognomônicos. Embora apresente limitações, a radiografia periapical deve ser o primeiro exame a ser realizado, pois possui menor custo e dose de radiação do que os exames tomográficos. O objetivo deste trabalho foi avaliar a contribuição de novas técnicas de processamento de imagens para o realce da FRV em radiografias periapicais digitais, visando facilitar sua detecção pelos odontologistas. O método de pré-processamento de imagem proposto foi composto de quatro etapas: ajuste geométrico+ negativo, filtragem de ruído, realce de contraste adaptativo e correção Gamma. Trinta radiografias periapicais digitais de dentes (fraturados ou não) tratados endodonticamente e com pino metálico instalado foram adquiridas. Resultados objetivos mostraram que o método desenvolvido aumentou o valor médio da razão contraste-ruído em 173% em comparação com o método de processamento tradicional fornecido pelo fabricante do equipamento. Testes subjetivos foram realizados com dez especialistas (radiologistas e endodontistas), que classificaram as imagens segundo a presença ou ausência de fratura. Os resultados indicaram que o método proposto melhorou a taxa de detecção de FRV pelos especialistas em 14%, em comparação com o método comercial, mas a especificidade foi reduzida. Dessa forma, a proposta deste trabalho pode ser utilizada como uma ferramenta complementar ao método de processamento tradicional, de modo a aumentar a sensibilidade do exame sem comprometer sua especificidade. / Vertical root fractures (VRF) are longitudinal fractures that occur at the root of the teeth. The clinical diagnosis of VRF is a challenge, since the patients have no pathognomonic signs and symptoms. Although it presents limitations, periapical radiography should be the first examination to be performed, because it has a lower cost and radiation dose than tomographic exams. The aim of this work was to evaluate the contribution of new image processing techniques for the enhancement of VRF in digital periapical radiographs, in order to facilitate its detection by dentists. The proposed image preprocessing method was composed of four steps: geometric adjustment+negative, noise filtering, adaptive contrast enhancement and Gamma correction. Thirty digital radiographs of teeth (fractured or not) treated endodontically and with installed metal pin were acquired. Objective results showed that the method developed increased the mean value of the contrast-to-noise ratio by 173% compared to the traditional processing method provided by the equipment manufacturer. Subjective tests were performed with ten examiners (radiologists and endodontists), who classified the images according to the presence or absence of fracture. The results indicated that the proposed method improved the detection rate of VRF by the examiners by 14% compared to the commercial method, but the specificity was reduced. Therefore, the proposal of this work can be used as a complementary tool to the traditional processing method, in order to increase the sensitivity of the test without compromising its specificity.
3

Estudo comparativo entre a tomografia volumétrica Cone Beam e radiografias periapicais no auxílio ao diagnóstico endodôntico / Comparative study between Cone-Beam volumetric tomography and periapical radiographs on helping endodontic diagnosis

D’Addazio, Paulo Sérgio dos Santos 30 January 2009 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-10-07T19:23:21Z No. of bitstreams: 1 paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-10-11T15:49:18Z (GMT) No. of bitstreams: 1 paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5) / Made available in DSpace on 2016-10-11T15:49:18Z (GMT). No. of bitstreams: 1 paulosergiodossantosdaddazio.pdf: 1362518 bytes, checksum: 07214ba3207394666338f0eeb8fcbd4e (MD5) Previous issue date: 2009-01-30 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo objetivou analisar comparativamente a tomografia volumétrica Cone-Beam e o exame radiográfico periapical, pela técnica de Clark, quanto à identificação de acidentes e complicações endodônticas, simuladas, de interesse endodôntico. Dezesseis dentes humanos, em três mandíbulas humanas, foram submetidos ao preparo de 20 alterações/lesões, de modo a simular situações que podem constituir-se em complicações para o diagnóstico e tratamento endodôntico. As simulações foram divididas em quatro grupos: G1) fragmento de lima fraturada no conduto radicular; G2) perfurações/rasgos no conduto radicular; G3) núcleos metálicos com desvio em relação ao trajeto do canal radicular e; G4) reabsorções externas. Cada dente foi submetido a exame radiográfico periapical pela técnica de Clark e cada mandíbula, a exame por Tomografia Computadorizada Cone-Beam. A análise dos exames foi realizada por um único observador, especialista em radiologia odontológica. Os resultados gerais utilizando-se o teste estatístico de McNemar demonstraram diferença estatisticamente significante (p < 0,05) para a Tomografia Computadorizada Cone-Beam em relação às radiografias periapicais. A análise estatística dos resultados individuais por alteração/lesão, utilizando-se o teste estatístico de Wilcoxon, demonstrou que houve superioridade da Tomografia Computadorizada Cone-Beam na identificação de reabsorções, com valor estatisticamente significante (p < 0,05). De acordo com os resultados pode-se concluir que, de uma forma geral, a Tomografia Computadorizada Cone-Beam apresentou superioridade em relação às radiografias periapicais convencionais, na identificação das alterações/lesões simuladas. / This study aimed to analyze and compare volumetric tomography ConeBeam and periapical examination, by technique of Clark, identifying accidents and endodontic complications, which were simulated, for endodontic interest. Sixteen human teeth from three human jaws were submitted to preparation of 20 changes/injuries in order to simulate situations that can lead to complications for diagnosis and endodontic treatment. The simulations were divided into four groups: G1) fragment of fractured file in radicular duct; G2) holes/slots in radicular duct; G3) metal cores with deviation from the path of root canal and, G4) external resorption. Each tooth was submitted to examination of periapical radiography, by technique of Clark and each jaw, by the examination of Cone-Beam Computed Tomography. The analysis of the tests was performed by a single observer, a specialist in dental radiology. The overall results using McNemar statistical test showed a difference statistically significant (p < 0.05) for Cone-Beam Computed Tomography if compared to periapical radiographs. Statistical analysis of individual results for alteration/defect, using Wilcoxon statistical test showed superiority of Cone-Beam Computed Tomography to identify resorptions, with statistically significant value (p < 0.05). According to the results it can be concluded that, generally, the Cone-Beam Computed Tomography showed superiority in relation to conventional periapical radiographs, identifying simulated changes/injuries.
4

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Pinheiro, Lucas Rodrigues 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
5

Identificação de dois canais radiculares em incisivos inferiores com imagens radiográficas, tomográficas e microtomográficas / Identification of two root canals in mandibular incisors using radiographic, tomographic and microtomographic images

Fernandes, Luciana Maria Paes da Silva Ramos 06 June 2014 (has links)
Os dentes incisivos inferiores apresentam, em sua maioria, canal radicular único, que pode ter conformações distintas. De acordo com a literatura científica, a presença de um segundo canal radicular pode ser constatada em 10 a 40% dos casos. A não-detecção do segundo canal é um importante fator para o insucesso do tratamento endodôntico. Esta pesquisa foi realizada com os seguintes objetivos: 1) comparar a eficácia na identificação de padrões anatômicos internos em incisivos inferiores permanentes extraídos com uso de imagem radiográfica periapical digital e de tomografia computadorizada de feixe cônico (TCFC); e 2) determinar a prevalência de 2 canais radiculares em incisivos inferiores em imagens de TCFC de um banco de dados de exames previamente realizados, associando com localização do dente, gênero e idade do paciente. Na primeira etapa da pesquisa, 40 dentes incisivos inferiores foram submetidos a escaneamento em microtomógrafo computadorizado da FOB-USP (Skyscan 1074) para estabelecer o padrão ouro do tipo anatômico interno de cada dente. Os dentes foram então classificados em: Tipo I (1 canal radicular regular, n=12), Tipo Ia (1 canal radicular oval, n=12) e Tipo III (2 canais radiculares, n=16). Em seguida, os dentes foram divididos em 10 grupos de 4 dentes e posicionados em alvéolos de uma mandíbula humana para exposição radiográfica periapical digital direta com duas tomadas variando o ângulo horizontal de incidência (Schick CDR) e para escaneamento em 3 tomógrafos (Kodak 9000 3D, Veraviewepocs 3De e NewTom 5G) da Universidade de Loma Linda, CA, EUA. Dois examinadores treinados classificaram o tipo anatômico de cada dente e suas respostas foram comparadas ao padrão ouro estabelecido por microtomografia. Para descrição dos resultados, utilizou-se a porcentagem (%) de respostas certas / erradas. Aplicou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%, para verificação da associação entre variáveis. As concordâncias inter e intraexaminador foram determinadas por teste de kappa. Na segunda etapa da pesquisa, foram interpretadas imagens de incisivos inferiores de 100 pacientes, cujos exames estavam disponíveis no banco de dados do tomógrafo i-CAT Classic da FOB-USP. Dois examinadores avaliaram a anatomia interna de incisivos inferiores, em reconstruções axiais, sagitais e coronais, classificando-a de acordo com o número de canais radiculares. A prevalência de 2 canais radiculares foi relacionada à localização do dente e ao gênero e idade do paciente. Para descrição dos dados coletados, utilizou-se a porcentagem (%). Para verificar a associação entre variáveis, utilizou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%. Para a concordância intra e interexaminador, utilizou-se o teste de kappa. Como resultado da primeira etapa da pesquisa, obteve-se alto índice de detecção de tipos anatômicos para todos os métodos avaliados (p <0,05). Para dentes com Tipo I (1 canal radicular regular), as imagens de TCFC foram superiores em comparação à radiografia periapical digital com dupla exposição (RP= 67% de acerto; TCFC= 98% de acerto, p <0,05). Considerando os 3 aparelhos de TCFC, não houve diferença estatística significante entre eles para identificação do Tipo I. Já para dentes com Tipo Ia (1 canal radicular oval), houve diferença estatística significante somente entre radiografia periapical digital com dupla exposição e o tomógrafo NewTom (RP= 44% de acerto; TCFC NewTom= 88% de acerto). Não houve diferença significante entre os outros 2 tomógrafos e radiografia periapical ou entre os 3 tomógrafos. Considerando dentes com Tipo III (2 canais radiculares), não houve diferença estatística significante entre nenhum dos métodos. Todos os métodos apresentaram números de respostas certas semelhantes para o Tipo III, sugerindo que a radiografia periapical com dupla angulação é suficiente para identificação de 2 canais radiculares em incisivos inferiores. A concordância intraexaminador para radiografia periapical foi regular (kappa=0,40 a 0,66) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,85). A concordância interexaminador para radiografia periapical foi de ruim a regular (kappa=0,25 a 0,32) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,92). Na segunda etapa da pesquisa, o total de 386 incisivos inferiores foi avaliado, sendo 192 incisivos centrais e 194 incisivos laterais. A prevalência de 2 canais radiculares constatada no total de dentes foi de 16,5%, sendo de 13% em incisivos centrais e de 20% nos incisivos laterais (p >0,05). Não houve diferença estatisticamente significante entre gêneros e idades. A concordância intra e interexaminador foi regular (kappa intra=0,60; kappa inter=0,57). Como conclusão da primeira etapa da pesquisa, observou-se que a identificação do número de canais radiculares foi efetiva em todos os métodos. No entanto, limitações foram encontradas para a diferenciação da forma do canal radicular. Na segunda etapa da pesquisa, concluiuse que a presença de 2 canais radiculares em incisivos inferiores de pacientes da região de Bauru é de aproximadamente 20% e não depende da localização do dente ou de gênero e idade do paciente. / Mandibular incisors most commonly have a single root canal, which can present with different anatomic configurations. According to the literature, the presence of a second root canal can be observed in 10 - 40% of the teeth. Difficulty in detecting the second root canal is an important factor for the endodontic treatment failure. The aim of this research was: 1) to compare the efficacy of digital periapical radiography (PA) with double exposure and cone beam computed tomography (CBCT) in the identification of internal anatomic patterns in mandibular incisors, and 2) to determine the prevalence of 2 root canals in mandibular incisors using cone beam computed tomographic images of a patient database, comparing to tooth position and patients gender and age. In the first part of this research, 40 extracted mandibular incisors underwent microcomputed tomographic (micro-CT) scanning (Skyscan 1074) in order to establish the gold standard for internal anatomic pattern. The teeth were classified according to: Type I (1 regular root canal, n=12), Type Ia (1 oval root canal, n=12), and Type III (2 root canals, n=16). Then, the teeth were divided into 10 groups of 4 teeth and placed in a preserved human mandible for direct digital periapical radiographic double exposure (Schick CDR) and CBCT scans using Kodak 9000 3D, Veraviewepocs 3De and NewTom 5G. Two blinded examiners classified the anatomic pattern of each tooth and their answers were compared to the gold standard (microtomographic images). Percentage (%) of right / wrong answers was used for the statistical analysis of the results. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. In the second part of this research, CBCT images of a 100 patients database from FOB-USP were examined. Two examiners assessed the internal anatomy of mandibular incisors in axial, sagittal and coronal reconstructions and classified the teeth according to the number of root canals. The prevalence of 2 root canals was related to the tooth location and patients gender and age. Percentage (%) was used to describe the collected data. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. The results of the first part of the research showed a high level of identification of anatomic patterns for all the methods (p <0.05). Considering Type I (1 regular root canal), CBCT images were better in comparison to PA (PA= 67%; CBCT= 98%, p <0.05). There was no significant difference between the 3 CBCT scanners. For Type Ia (1 oval root canal), there was a significant difference between PA and CBCT imaging using the NewTom unit only (PA= 44%, NewTom CBCT= 88%). No significant differences were found between the other 2 CBCT units and PA or between the 3 CBCT units. Considering Type III (2 root canals), there was no significant difference between the various methods. All the methods presented similar corrected answers index for Type III, which may suggest that PA with double exposure is sufficient for the identification of 2 root canals in mandibular incisors. The intraexaminer agreement was fair for PA (kappa=0.40 to 0.66) and good to very good for the CBCT units (kappa=0.62 to 0.85). The interexaminer agreement was poor to fair for PA (kappa=0.25 to 0.32) and good to very good for CBCT units (kappa=0.62 to 0.92). In the second part of this research, the total amount of 386 mandibular incisors was assessed in CBCT images (192 mandibular central incisors and 194 mandibular lateral incisors). The overall prevalence of 2 root canals was 16.5%, and 13% in mandibular central incisors and 20% in mandibular lateral incisors (p >0.05). There was no significant difference between gender and age. The intra and interexaminer agreement was fair (kappa intra=0.60; kappa inter=0.57). For the first part of this research, it is possible to conclude that the identification of the number of root canals was effective using all the methods. However, limitations were found in differentiating the shape of the root canal. As a conclusion of the second part of this research, the presence of 2 root canals in mandibular incisors of Bauru region patients is approximately 20% and it does not depend on tooth location or patients gender and age.
6

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Lucas Rodrigues Pinheiro 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
7

Identificação de dois canais radiculares em incisivos inferiores com imagens radiográficas, tomográficas e microtomográficas / Identification of two root canals in mandibular incisors using radiographic, tomographic and microtomographic images

Luciana Maria Paes da Silva Ramos Fernandes 06 June 2014 (has links)
Os dentes incisivos inferiores apresentam, em sua maioria, canal radicular único, que pode ter conformações distintas. De acordo com a literatura científica, a presença de um segundo canal radicular pode ser constatada em 10 a 40% dos casos. A não-detecção do segundo canal é um importante fator para o insucesso do tratamento endodôntico. Esta pesquisa foi realizada com os seguintes objetivos: 1) comparar a eficácia na identificação de padrões anatômicos internos em incisivos inferiores permanentes extraídos com uso de imagem radiográfica periapical digital e de tomografia computadorizada de feixe cônico (TCFC); e 2) determinar a prevalência de 2 canais radiculares em incisivos inferiores em imagens de TCFC de um banco de dados de exames previamente realizados, associando com localização do dente, gênero e idade do paciente. Na primeira etapa da pesquisa, 40 dentes incisivos inferiores foram submetidos a escaneamento em microtomógrafo computadorizado da FOB-USP (Skyscan 1074) para estabelecer o padrão ouro do tipo anatômico interno de cada dente. Os dentes foram então classificados em: Tipo I (1 canal radicular regular, n=12), Tipo Ia (1 canal radicular oval, n=12) e Tipo III (2 canais radiculares, n=16). Em seguida, os dentes foram divididos em 10 grupos de 4 dentes e posicionados em alvéolos de uma mandíbula humana para exposição radiográfica periapical digital direta com duas tomadas variando o ângulo horizontal de incidência (Schick CDR) e para escaneamento em 3 tomógrafos (Kodak 9000 3D, Veraviewepocs 3De e NewTom 5G) da Universidade de Loma Linda, CA, EUA. Dois examinadores treinados classificaram o tipo anatômico de cada dente e suas respostas foram comparadas ao padrão ouro estabelecido por microtomografia. Para descrição dos resultados, utilizou-se a porcentagem (%) de respostas certas / erradas. Aplicou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%, para verificação da associação entre variáveis. As concordâncias inter e intraexaminador foram determinadas por teste de kappa. Na segunda etapa da pesquisa, foram interpretadas imagens de incisivos inferiores de 100 pacientes, cujos exames estavam disponíveis no banco de dados do tomógrafo i-CAT Classic da FOB-USP. Dois examinadores avaliaram a anatomia interna de incisivos inferiores, em reconstruções axiais, sagitais e coronais, classificando-a de acordo com o número de canais radiculares. A prevalência de 2 canais radiculares foi relacionada à localização do dente e ao gênero e idade do paciente. Para descrição dos dados coletados, utilizou-se a porcentagem (%). Para verificar a associação entre variáveis, utilizou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%. Para a concordância intra e interexaminador, utilizou-se o teste de kappa. Como resultado da primeira etapa da pesquisa, obteve-se alto índice de detecção de tipos anatômicos para todos os métodos avaliados (p <0,05). Para dentes com Tipo I (1 canal radicular regular), as imagens de TCFC foram superiores em comparação à radiografia periapical digital com dupla exposição (RP= 67% de acerto; TCFC= 98% de acerto, p <0,05). Considerando os 3 aparelhos de TCFC, não houve diferença estatística significante entre eles para identificação do Tipo I. Já para dentes com Tipo Ia (1 canal radicular oval), houve diferença estatística significante somente entre radiografia periapical digital com dupla exposição e o tomógrafo NewTom (RP= 44% de acerto; TCFC NewTom= 88% de acerto). Não houve diferença significante entre os outros 2 tomógrafos e radiografia periapical ou entre os 3 tomógrafos. Considerando dentes com Tipo III (2 canais radiculares), não houve diferença estatística significante entre nenhum dos métodos. Todos os métodos apresentaram números de respostas certas semelhantes para o Tipo III, sugerindo que a radiografia periapical com dupla angulação é suficiente para identificação de 2 canais radiculares em incisivos inferiores. A concordância intraexaminador para radiografia periapical foi regular (kappa=0,40 a 0,66) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,85). A concordância interexaminador para radiografia periapical foi de ruim a regular (kappa=0,25 a 0,32) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,92). Na segunda etapa da pesquisa, o total de 386 incisivos inferiores foi avaliado, sendo 192 incisivos centrais e 194 incisivos laterais. A prevalência de 2 canais radiculares constatada no total de dentes foi de 16,5%, sendo de 13% em incisivos centrais e de 20% nos incisivos laterais (p >0,05). Não houve diferença estatisticamente significante entre gêneros e idades. A concordância intra e interexaminador foi regular (kappa intra=0,60; kappa inter=0,57). Como conclusão da primeira etapa da pesquisa, observou-se que a identificação do número de canais radiculares foi efetiva em todos os métodos. No entanto, limitações foram encontradas para a diferenciação da forma do canal radicular. Na segunda etapa da pesquisa, concluiuse que a presença de 2 canais radiculares em incisivos inferiores de pacientes da região de Bauru é de aproximadamente 20% e não depende da localização do dente ou de gênero e idade do paciente. / Mandibular incisors most commonly have a single root canal, which can present with different anatomic configurations. According to the literature, the presence of a second root canal can be observed in 10 - 40% of the teeth. Difficulty in detecting the second root canal is an important factor for the endodontic treatment failure. The aim of this research was: 1) to compare the efficacy of digital periapical radiography (PA) with double exposure and cone beam computed tomography (CBCT) in the identification of internal anatomic patterns in mandibular incisors, and 2) to determine the prevalence of 2 root canals in mandibular incisors using cone beam computed tomographic images of a patient database, comparing to tooth position and patients gender and age. In the first part of this research, 40 extracted mandibular incisors underwent microcomputed tomographic (micro-CT) scanning (Skyscan 1074) in order to establish the gold standard for internal anatomic pattern. The teeth were classified according to: Type I (1 regular root canal, n=12), Type Ia (1 oval root canal, n=12), and Type III (2 root canals, n=16). Then, the teeth were divided into 10 groups of 4 teeth and placed in a preserved human mandible for direct digital periapical radiographic double exposure (Schick CDR) and CBCT scans using Kodak 9000 3D, Veraviewepocs 3De and NewTom 5G. Two blinded examiners classified the anatomic pattern of each tooth and their answers were compared to the gold standard (microtomographic images). Percentage (%) of right / wrong answers was used for the statistical analysis of the results. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. In the second part of this research, CBCT images of a 100 patients database from FOB-USP were examined. Two examiners assessed the internal anatomy of mandibular incisors in axial, sagittal and coronal reconstructions and classified the teeth according to the number of root canals. The prevalence of 2 root canals was related to the tooth location and patients gender and age. Percentage (%) was used to describe the collected data. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. The results of the first part of the research showed a high level of identification of anatomic patterns for all the methods (p <0.05). Considering Type I (1 regular root canal), CBCT images were better in comparison to PA (PA= 67%; CBCT= 98%, p <0.05). There was no significant difference between the 3 CBCT scanners. For Type Ia (1 oval root canal), there was a significant difference between PA and CBCT imaging using the NewTom unit only (PA= 44%, NewTom CBCT= 88%). No significant differences were found between the other 2 CBCT units and PA or between the 3 CBCT units. Considering Type III (2 root canals), there was no significant difference between the various methods. All the methods presented similar corrected answers index for Type III, which may suggest that PA with double exposure is sufficient for the identification of 2 root canals in mandibular incisors. The intraexaminer agreement was fair for PA (kappa=0.40 to 0.66) and good to very good for the CBCT units (kappa=0.62 to 0.85). The interexaminer agreement was poor to fair for PA (kappa=0.25 to 0.32) and good to very good for CBCT units (kappa=0.62 to 0.92). In the second part of this research, the total amount of 386 mandibular incisors was assessed in CBCT images (192 mandibular central incisors and 194 mandibular lateral incisors). The overall prevalence of 2 root canals was 16.5%, and 13% in mandibular central incisors and 20% in mandibular lateral incisors (p >0.05). There was no significant difference between gender and age. The intra and interexaminer agreement was fair (kappa intra=0.60; kappa inter=0.57). For the first part of this research, it is possible to conclude that the identification of the number of root canals was effective using all the methods. However, limitations were found in differentiating the shape of the root canal. As a conclusion of the second part of this research, the presence of 2 root canals in mandibular incisors of Bauru region patients is approximately 20% and it does not depend on tooth location or patients gender and age.
8

Avaliação da acurácia da tomografia computadorizada de feixe cônico na detecção de fraturas radiculares verticais em dentes com núcleo metálico fundido

Junqueira, Rafael Binato 14 January 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-21T13:18:07Z No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:11:04Z (GMT) No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) / Made available in DSpace on 2016-04-24T02:11:04Z (GMT). No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) Previous issue date: 2013-01-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O diagnóstico de fraturas radiculares verticais constitui um desafio para o cirurgiãodentista, e sua detecção precoce dependerá da busca de sinais clínicos e radiográficos. Os exames complementares são fundamentais neste processo, destacando-se a radiografia periapical e a tomografia computadorizada de feixe cônico (TCFC). Entretanto, em dentes tratados endodonticamente e que possuem núcleo metálico, a avaliação da imagem tomográfica pode ser prejudicada pela formação de artefatos. O presente estudo avaliou a acurácia da tomografia computadorizada de feixe cônico na detecção de fraturas radiculares verticais em dentes com núcleo metálico fundido. Dezoito dentes humanos monorradiculares foram tratados endodonticamante e preparados para núcleo metálico fundido, sendo submetidos à fratura radicular vertical in vitro, recobertos com cera e posicionados em alvéolos de mandíbulas secas. Toda a amostra foi submetida duas vezes (com e sem núcleo) à radiografia periapical digital pela técnica de Clark e a exames de TCFC com dois voxels: 0,125 mm e 0,25 mm. As imagens foram avaliadas por três radiologistas e os resultados submetidos à análise estatística. Foram calculados os índices de sensibilidade, especificidade, preditivo positivo e preditivo negativo, além das áreas sob as curvas ROC (acurácia). As acurácias dos exames foram comparadas pelo teste qui-quadrado, não havendo diferença significativa (p≥0,05). A comparação entre os dentes com e sem núcleo em cada exame, pelo teste exato de Fischer, revelou diferença significativa para a TCFC com voxel de 0,125 e para a radiografia periapical (p<0,05). As imagens com voxel de 0,125 tiveram maior acurácia nos dentes sem núcleo, porém, sem diferença significativa. Concluiu-se que a radiografia periapical digital, com variação da angulação horizontal, deve ser o primeiro exame complementar realizado para a investigação de fraturas radiculares verticais. Caso este método seja inconclusivo, a TCFC mostra-se como alternativa eficaz nos dentes sem núcleo metálico. / The diagnosis of vertical root fractures is a challenge to dentists, and early detection will depend on the search of clinical and radiographic signs. Complementary exams are very important in this process, highlighting periapical radiography and cone beam computed tomography (CBCT). However, in endodontically treated and with metallic post teeth, the evaluation of tomographic image can be worse due to artifacts. The present study evaluated the accuracy of CBCT in detection of vertical root fractures in teeth with metallic cast post. Eighteen monorradicular human teeth were endodontically treated and prepared to metallic post. They were subjected to fractures in vitro, recovered with wax and inserted in dry human skulls. The sample was submitted twice (with and without metallic post) to periapical radiography and CBCT (2 voxels: 0,125mm e 0,25 mm).The images were analyzed by three radiologists and the results were submitted to statistical analysis. Sensibility, specificity, positive predictive and negative predictive values were calculated, beyond the areas under ROC curves (accuracy). The accuracy of the exams were compared by chi-squared test, showing no significant differences (p≥0,05). The comparisons between teeth with and without metallic posts in each exam, by Fischer exact test, revealed significant difference to CBCT voxel 0,125 and periapical radiography (p<0,05). The images of CBCT voxel 0,125 were more accurate in teeth without metallic post, although with no significance. It was concluded that periapical digital radiography, with variation of the horizontal angle, should be the first supplementary exam held for investigation of vertical root fractures. If this method is inconclusive, CBTC shows up an effective alternative in teeth without metallic post.

Page generated in 0.0876 seconds