• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • Tagged with
  • 6
  • 6
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Factors related to vertical root fractures in teeth restored with prosthetic single crowns: A retrospective clinical study

Al-Hotheiry, Sham, Spahic, Mustafa January 2022 (has links)
Purpose The aim of the present retrospective clinical study was to investigate the factors that could be associated with the occurrence of vertical root fractures regarding tooth-supported single crowns (VRF). Materials and methods This dental record-based retrospective study included patients treated with tooth-supported single crowns during from October 2008 to December 2010 at the Faculty of Odontology, Malmö University, Sweden. All patients rehabilitated with one or more tooth-supported single prosthetic crowns during the aforementioned period were included. The patients needed to have at least 6 months of follow-up and an available digital periapical radiograph taken within 12 months after delivery of the prosthesis (crown cementation). Univariate and multivariate Cox regression models were used to evaluate the associations between 14 clinical covariates and VRF. Results Only 96 single-crowns in 72 patients fulfilled the inclusion criteria. The location of teeth, in the mandible in relation to teeth in the maxilla, related to their posterior position in the jaws, was identified in the Cox regression model as being associated with VRF. Conclusion Tooth-supported single crowns located in the mandible, directly related to the fact that they were located posteriorly, was the factor associated with the occurrence of VRF. However, it is not possible to draw robust conclusions about the results of the present study, due to the small sample size of the present cohort, which was a consequence of many difficulties that arouse during the conduction of the study. More available data would be needed in order to answer important questions about external validity of the present results. / Syfte Syftet med den aktuella retrospektiva kliniska studien var att undersöka de faktorer som kan associeras med uppkomsten av vertikala rotfrakturer (VRF) avseende tandstödda singelkronor.Material och metod Denna retrospektiva studie baserades på tandvårdsjournaler och inkluderade patienter som behandlats med tandstödda singelkronor under perioden från oktober 2008 till december 2010 vid Odontologiska fakulteten, Malmö Universitet, Sverige. Alla patienter som behandlades med en eller flera tandstödda protetiska singelkronor under den tidigare nämnda perioden inkluderades. Patienterna behövde ha minst 6 månaders uppföljning och en tillgänglig digital periapikal röntgenbild tagen inom 12 månader efter utlämning av den protetiska ersättningen (kroncementering). Univariata och multivariata Cox-regressionsmodeller användes för att utvärdera sambanden mellan 14 kliniska kovariater och VRF.Resultat Endast 96 singelkronor hos totalt 72 patienter uppfyllde inklusionskriterierna. Förhållandet som identifierades i Cox-regressionsmodellen är att placeringen av tänder i underkäken i förhållande till tänder i överkäken är associerad med VRF, där relationen kunde relateras till den posteriora regionen i underkäken. Slutsats Tanstödda singelkronor installerade i den posteriora regionen i mandibeln, är faktorn som är förknippad med förekomsten av VRF. Det är dock inte möjligt att dra drastiska slutsatser om resultaten av den föreliggande studien på grund av den lilla urvalsstorleken för den nuvarande kohorten, vilket var till följd av många svårigheter som uppstod under genomförandet av studien. Mer tillgängliga data skulle behövas för att besvara viktiga frågor om extern validitet av de nuvarande resultaten.
2

EFEITO DO TIPO DE INSTRUMENTO E DA TÉCNICA OBTURADORA NA RESISTÊNCIA À FRATURA DE DENTES RESTAURADOS. / EFFECT OF THE INSTRUMENT TYPE AND ROOT CANAL FILLING TECHNIQUE ON FRACTURE RESISTANCE OF RESTORED ROOTS

Santini, Manuela Favarin 03 March 2012 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study was to assess the effect of instrument type (K-files and nickel-titanium rotary files) and the root canal filling technique (active and passive lateral condensation) on fracture resistance. Sixty eight teeth (canines and premolars) were divided into 4 groups (n=17): G1 - hand instrumentation and active lateral condensation; G2 - hand instrumentation and passive lateral condensation; G3 - rotary instrumentation and active lateral condensation; G4 - rotary instrumentation and passive lateral condensation. Before the filling, the roots were embedded in acrylic resin to simulate the periodontal ligament using a polyether impression material. Every root was restored with glass fiber post and metallic crown. The specimens were mechanical cycled (500.000 cycles, 45°, 37° C, 133 N, 2 Hz) and they were submitted to fracture test (45º, 1 mm/ min) until the fracture occurred. The Kruskal-Wallis test showed that the groups were not different from each other (p = 0. 247). In situations where an endodontic post is required, the instrument type and the obturation technique seem to have no influence on fracture resistance. / O objetivo deste estudo foi avaliar o efeito do tipo de instrumento (limas manuais tipo K e instrumentos rotatórios de NiTi) e da técnica obturadora (condensação lateral ativa e condensação lateral passiva) na resistência à fratura. Para isso, 68 dentes (caninos e pré-molares) foram divididos em 4 grupos (n=17): G1 - instrumentação manual e condensação lateral ativa; G2 - instrumentação manual e condensação lateral passiva; G3 - instrumentação rotatória e condensação lateral ativa; G4 - instrumentação rotatória e condensação lateral passiva. Antes da etapa obturadora, as raízes foram embutidas em resina acrílica para a simulação do ligamento periodontal com material de moldagem à base de poliéter. Todas as raízes foram restauradas com pino de fibra de vidro e coroa metálica. Os espécimes foram submetidos à ciclagem mecânica (500.000 ciclos, 45°, 37° C, 133 N, 2 Hz) e ao teste de resistência à fratura (45º, 1 mm/ min) até a falha ocorrer. O teste de Kruskal-Wallis mostrou que os grupos não foram diferentes entre si (p = 0, 247). Em situações em que há a necessidade de cimentação de pino intrarradicular, a escolha do tipo de instrumento e da técnica obturadora parece não ter influência na resistência à fratura.
3

Acurácia de dois tomógrafos na detecção de fraturas radiculares verticais em dentes com retentores metálicos intracanais / Accuracy of two cone beam computed tomography systems for the detection of vertical root fractures

Siqueira, Claudeir Felipe de Oliveira 10 March 2017 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-19T12:09:37Z No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-04-19T12:13:10Z (GMT) No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-04-19T12:13:10Z (GMT). No. of bitstreams: 2 Dissertação - Claudeir Felipe de Oliveira Siqueira - 2017.pdf: 2068338 bytes, checksum: b1222b1c483b31d5a02f7ca3259bb2aa (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-03-10 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / Vertical root fracture (VRF) is a dental lesion with worse prognosis in dentistry, the diagnosis is made from clinical evaluation, and image exams, clinically the symptoms are signaled and not pathognomonic and even with the introduction of cone beam computed tomography, the metallic artifacts resulting from the images obtained still make it difficult to detect VRF. The aim of this study was to evaluate the accumulation of Eagle 3D and i-Cat tomography in the detection of VRF in endodontically treated single-root teeth with post metallic intracanal. This study was approved by the Research Ethics Committee of UFG under the number 477.315. 30 single-root teeth were endodontically treated and prepared with metal pins. The sample was divided randomly in Control Group (CTL) and Fractured Group (FRT). The fractures were made only in FRT Group by the Universal Test machine, with load cell 500N and speed of 1mm/ min. The teeth were placed in dry jaw and placed in a vessel with distilled water to be purchased as TCFC images by Eagle 3D tomographs (protocol 1: FOV 5X5 cm and voxel: 0.1 mm - protocol 2: FOV 6X8 cm and voxel: 0.16 mm) and i-CAT (protocol 3: FOV 8 × 8 cm and voxel: 0.125 mm - protocol 4: FOV 8 × 8 cm and voxel: 0.2 mm). Two experienced evaluators classified as composite images by absence of fracture or by subjective revisions of an interference of the formation of non-diagnostic artefacts and reconstruction type and efficient in the detection of VRF. The inter-examiner agreement was verified by kappa test. Measurements of sensitivity, specificity and accuracy were adopted for each device. The area under the ROC curve was also calculated and compared using the ANOVA. The results indicated that protocols 1 and 3 were more accurate (AUC protocol 1: 0.784 - p <0.05 and AUC protocol 2: 0.729 - p <0.05). According to the subjective evaluation of the examiners, in protocols 1 and 4 of greater interference of the formation of artifacts without diagnosis of VRF and a parasagittal reconstruction was the most efficient for a detection of the fracture line. It is concluded that protocols 1 and 3 highlight a better performance in the detection of VRF and that the size of voxel is a factor that directly influences the accuracy. / Resumo: A fratura radicular vertical (FRV) é a lesão dentária com o pior prognóstico na Odontologia. O diagnóstico é um desafio, pois clinicamente os pacientes apresentam sinais e sintomas não patognomônicos e apesar da introdução da tomografia computadorizada de feixe cônico (TCFC) como ferramenta de diagnóstico , os artefatos metálicos resultantes das imagens obtidas tornam difícil a detecção da FRV. Vários fatores de digitalização e reconstrução incluindo FOV (Field of view), tamanho do voxel, o número de projeções base (aquisições) para a reconstrução e a formação de artefatos na imagem tem influência significativa na acurácia do exame. O objetivo deste trabalho foi avaliar a acurácia dos tomógrafos Eagle 3D e i-Cat na detecção de FRV em dentes unirradiculares tratados endodonticamente com retentor metálico intracanal. Foram tratados endodonticamente e confeccionados pinos metálicos em 30 dentes unirradiculares. A amostra foi randomicamente dividida em dois grupos: Grupo Controle (CTL) e Grupo Fraturado (FRT). As fraturas foram confeccionadas somente no Grupo FRT pela Máquina de Ensaios Universal, com célula de carga 500N e velocidade de 1mm/min. Os dentes foram posicionados em mandíbula seca e colocados em um recipiente com água destilada para serem adquiridas as imagens de TCFC pelos tomógrafos Eagle 3D (protocolo 1: FOV 5X5 cm e voxel: 0,1 mm - protocolo 2: FOV 6X8 cm e voxel: 0,16 mm) e i-CAT (protocolo 3: FOV 8X8 cm e voxel: 0,125 mm - protocolo 4: FOV 8X8 cm e voxel: 0,2 mm). Dois avaliadores experientes classificaram as imagens conforme a presença ou ausência de fratura e avaliaram a interferência dos artefatos e do tipo de reconstrução na detecção de FRV. A concordância interexaminador foi verificada pelo teste kappa. As medidas de sensibilidade, especificidade e acurácia foram medidas para cada aparelho. Também foi calculada a área sob a curva (AUC) ROC, e os resultados comparados utilizando o modelo de análise variância (ANOVA). Os resultados indicaram que os protocolos 1 e 3 foram mais acurados (AUC protocolo 1: 0,784 – p<0,05 e AUC protocolo 2: 0,729 – p<0,05). Segundo avaliação subjetiva dos examinadores, nos protocolos 1 e 4 há maior interferência da formação de artefatos no diagnóstico de FRV e a reconstrução transversal se mostrou mais eficiente para a detecção da linha de fratura. Conclui-se que os protocolos 1 (Eagle 3D: FOV 5X5 cm e voxel: 0,1 mm) e 3 (i-CAT: FOV 8X8 cm e voxel: 0,125 mm) apresentam melhor acurácia na detecção de FRV e que o tamanho do voxel é um fator que influência diretamente na acurácia
4

Avaliação da acurácia da tomografia computadorizada de feixe cônico na detecção de fraturas radiculares verticais em dentes com núcleo metálico fundido

Junqueira, Rafael Binato 14 January 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-21T13:18:07Z No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:11:04Z (GMT) No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) / Made available in DSpace on 2016-04-24T02:11:04Z (GMT). No. of bitstreams: 1 rafaelbinatojunqueira.pdf: 3138866 bytes, checksum: 0ad9fc0b6e140d0a267c6e92dbbec5fa (MD5) Previous issue date: 2013-01-14 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O diagnóstico de fraturas radiculares verticais constitui um desafio para o cirurgiãodentista, e sua detecção precoce dependerá da busca de sinais clínicos e radiográficos. Os exames complementares são fundamentais neste processo, destacando-se a radiografia periapical e a tomografia computadorizada de feixe cônico (TCFC). Entretanto, em dentes tratados endodonticamente e que possuem núcleo metálico, a avaliação da imagem tomográfica pode ser prejudicada pela formação de artefatos. O presente estudo avaliou a acurácia da tomografia computadorizada de feixe cônico na detecção de fraturas radiculares verticais em dentes com núcleo metálico fundido. Dezoito dentes humanos monorradiculares foram tratados endodonticamante e preparados para núcleo metálico fundido, sendo submetidos à fratura radicular vertical in vitro, recobertos com cera e posicionados em alvéolos de mandíbulas secas. Toda a amostra foi submetida duas vezes (com e sem núcleo) à radiografia periapical digital pela técnica de Clark e a exames de TCFC com dois voxels: 0,125 mm e 0,25 mm. As imagens foram avaliadas por três radiologistas e os resultados submetidos à análise estatística. Foram calculados os índices de sensibilidade, especificidade, preditivo positivo e preditivo negativo, além das áreas sob as curvas ROC (acurácia). As acurácias dos exames foram comparadas pelo teste qui-quadrado, não havendo diferença significativa (p≥0,05). A comparação entre os dentes com e sem núcleo em cada exame, pelo teste exato de Fischer, revelou diferença significativa para a TCFC com voxel de 0,125 e para a radiografia periapical (p<0,05). As imagens com voxel de 0,125 tiveram maior acurácia nos dentes sem núcleo, porém, sem diferença significativa. Concluiu-se que a radiografia periapical digital, com variação da angulação horizontal, deve ser o primeiro exame complementar realizado para a investigação de fraturas radiculares verticais. Caso este método seja inconclusivo, a TCFC mostra-se como alternativa eficaz nos dentes sem núcleo metálico. / The diagnosis of vertical root fractures is a challenge to dentists, and early detection will depend on the search of clinical and radiographic signs. Complementary exams are very important in this process, highlighting periapical radiography and cone beam computed tomography (CBCT). However, in endodontically treated and with metallic post teeth, the evaluation of tomographic image can be worse due to artifacts. The present study evaluated the accuracy of CBCT in detection of vertical root fractures in teeth with metallic cast post. Eighteen monorradicular human teeth were endodontically treated and prepared to metallic post. They were subjected to fractures in vitro, recovered with wax and inserted in dry human skulls. The sample was submitted twice (with and without metallic post) to periapical radiography and CBCT (2 voxels: 0,125mm e 0,25 mm).The images were analyzed by three radiologists and the results were submitted to statistical analysis. Sensibility, specificity, positive predictive and negative predictive values were calculated, beyond the areas under ROC curves (accuracy). The accuracy of the exams were compared by chi-squared test, showing no significant differences (p≥0,05). The comparisons between teeth with and without metallic posts in each exam, by Fischer exact test, revealed significant difference to CBCT voxel 0,125 and periapical radiography (p<0,05). The images of CBCT voxel 0,125 were more accurate in teeth without metallic post, although with no significance. It was concluded that periapical digital radiography, with variation of the horizontal angle, should be the first supplementary exam held for investigation of vertical root fractures. If this method is inconclusive, CBTC shows up an effective alternative in teeth without metallic post.
5

Risco de fratura radicular em pré-molar superior restaurado com pino intra-radicular: análise por elementos finitos / Risk of root fracture in upper premolars restored with an intraradicular post: finite element analysis

Santos, Andrea Fagundes Vaz dos 17 February 2009 (has links)
A restauração de dentes com grande destruição tecidual e endodonticamente tratados ainda representa um desafio para o cirurgião-dentista. A falha mais crítica após este tipo de tratamento é a fratura radicular, com maior incidência no grupo dos pré-molares superiores. O achatamento mésio-distal dos canais destes dentes e o descolamanto do pino oval têm sido apontados como os principais fatores predisponentes para este tipo de fratura. A hipótese deste trabalho é que a presença do pino aumenta o risco de fratura quando ocorre concomitantemente descolamento na interface pino/cimento. Este risco seria maior nos casos em que o pino acompanha o formato oval característico do canal do segundo pré-molar superior. O objetivo deste trabalho foi comparar, por análise de elementos finitos, as respostas de tensão máxima principal (smax) em modelos que simularam pinos de seção transversal circular ou oval, aderidos ou descolados e em modelos de dentes hígidos com canal de seção transversal circular ou oval. Foi avaliado também o risco de descolamento da interface pino/cimento. Foram construídos dois modelos 3D de segundo pré-molar superior hígido, um com canal oval (Ho) e outro com canal circular (Hc). A partir dos modelos dos dentes hígidos foram construídos modelos com pino intra-radicular de fibra de vidro e com núcleo metálico fundido. Para os casos de canais ovais (Co), os pinos poderiam apresentar seções transversais circular (Pc) ou oval (Po), enquanto para os canais circulares (Cc) foram simulados apenas pinos circulares. Todos os materiais foram considerados homogêneos, lineares e isotrópicos, com exceção do pino de fibra de vidro que foi considerado ortotrópico. Para cada modelo foi simulada uma condição de perfeita adesão (A) e outra de total descolamento (D) entre pino e cimento resinoso. Uma carga de 300 N foi aplicada a 45° na aresta central-interna da cúspide vestibular (carregamento cêntrico) ou desviada 1,4 mm para a mesial (carregamento excêntrico). Os diferentes modelos foram comparados quanto à distribuição da smax e magnitude, localização e orientação dos vetores dos picos de smax na dentina. Foi analisado também o risco de descolamento da interface pino/cimento, e os riscos de fratura do pino, núcleo e cimento. O pico de tração para os casos D foi de até 4,7 vezes maior que o encontrado nos dentes hígidos e nos casos A. Nos casos D, os pinos circulares chegam a apresentar tensão 1,7 vezes maior que os ovais. Ainda para os casos D, as raízes de seção transversal circular tiveram smax 1,3 vezes maior que as de seção transversal oval, mantendo o pino sempre circular. Já para os casos A, os valores foram muito semelhantes (embora, em geral, um pouco maiores) aos do dente hígido. O maior risco de descolamento foi detectado entre pino metálico fundido e cimento. O risco de fraturar a raiz foi maior em pinos descolados com pino metálico. Em raízes restauradas com pino de fibra, o maior risco de fratura ocorreu no núcleo e no pino, embora o valor do índice de risco de fratura seja muito mais alto que para os dentes restaurados com pino metálico. / The restoration of teeth with a large tissue destruction and endodontic treatment still presents a challenge for clinicians. The most critical failure after this type of treatment is the root fracture, with more incidence for upper premolars. The mesial-distal flattening of the root canal of these teeth and the detachment of the oval post have been pointed out as main factors predisposed to this type of fracture. The hypothesis of this study is that the presence of posts increases the risk of failure when this happens concomitantly to its detachment at the post/cement interface. This risk would be greater for cases in which the post follows the typical oval shape of the upper second premolar root canal. The objective of this study was to compare, by finite element analysis, the reply of the maximum principal stress (smax) for models which simulated posts with circular or oval cross-section, bonded or detached and for intact teeth models with circular or oval root canal. The risk of post/cement interface detachment was also evaluated. Two 3D models of an intact upper premolar, one with an oval canal (Ho) and other with a circular one (Hc) were obtained. From these models, other ones were obtained with glass fiber intra-radicular post and with cast core. For oval canals (Co), posts could presented circular (Pc) or oval (Po) crosssections, while for circular ones (Cc), only circular posts were simulated. All materials were considered homogeneous, linear and isotropic, except the glass fiber post which was considered orthotropic. For each model, a perfect bonding condition was simulated (A) and another with total detachment (D) between the post and the cement. A 300 N load was applied at 45° on the central-internal edge of the buccal cusp (centric loading) or diverted from 1,4 mm through the mesial (excentric loading). All different models were compared on stress distribution of smax and magnitude, and also smax peak vectors localization, and orientation at the dentin. The post/cement interface risk of detachment and the risk of fracture for posts, core and cement were analyzed. The tension peak for D cases was up to 4,7 times greater than that found for intact teeth and for A cases. For D cases, circular posts sometimes presented up to 1,7 times greater than oval ones. Further for D cases, roots with circular crosssectional had the smax 1,3 times greater than those with oval cross-sectional, with the post always circular. For A cases, values were however much similar (even though, in general, they were a little greater) to intact ones. The major risk of detachment was detected between the metallic post and the cement. The risk of root fracture is greater for detached posts with metallic posts. For restored roots with fiber posts, the major risk of fracture occurs to the core and the post, even the risk of fracture index is much greater than for restored teeth with metallic post.
6

Risco de fratura radicular em pré-molar superior restaurado com pino intra-radicular: análise por elementos finitos / Risk of root fracture in upper premolars restored with an intraradicular post: finite element analysis

Andrea Fagundes Vaz dos Santos 17 February 2009 (has links)
A restauração de dentes com grande destruição tecidual e endodonticamente tratados ainda representa um desafio para o cirurgião-dentista. A falha mais crítica após este tipo de tratamento é a fratura radicular, com maior incidência no grupo dos pré-molares superiores. O achatamento mésio-distal dos canais destes dentes e o descolamanto do pino oval têm sido apontados como os principais fatores predisponentes para este tipo de fratura. A hipótese deste trabalho é que a presença do pino aumenta o risco de fratura quando ocorre concomitantemente descolamento na interface pino/cimento. Este risco seria maior nos casos em que o pino acompanha o formato oval característico do canal do segundo pré-molar superior. O objetivo deste trabalho foi comparar, por análise de elementos finitos, as respostas de tensão máxima principal (smax) em modelos que simularam pinos de seção transversal circular ou oval, aderidos ou descolados e em modelos de dentes hígidos com canal de seção transversal circular ou oval. Foi avaliado também o risco de descolamento da interface pino/cimento. Foram construídos dois modelos 3D de segundo pré-molar superior hígido, um com canal oval (Ho) e outro com canal circular (Hc). A partir dos modelos dos dentes hígidos foram construídos modelos com pino intra-radicular de fibra de vidro e com núcleo metálico fundido. Para os casos de canais ovais (Co), os pinos poderiam apresentar seções transversais circular (Pc) ou oval (Po), enquanto para os canais circulares (Cc) foram simulados apenas pinos circulares. Todos os materiais foram considerados homogêneos, lineares e isotrópicos, com exceção do pino de fibra de vidro que foi considerado ortotrópico. Para cada modelo foi simulada uma condição de perfeita adesão (A) e outra de total descolamento (D) entre pino e cimento resinoso. Uma carga de 300 N foi aplicada a 45° na aresta central-interna da cúspide vestibular (carregamento cêntrico) ou desviada 1,4 mm para a mesial (carregamento excêntrico). Os diferentes modelos foram comparados quanto à distribuição da smax e magnitude, localização e orientação dos vetores dos picos de smax na dentina. Foi analisado também o risco de descolamento da interface pino/cimento, e os riscos de fratura do pino, núcleo e cimento. O pico de tração para os casos D foi de até 4,7 vezes maior que o encontrado nos dentes hígidos e nos casos A. Nos casos D, os pinos circulares chegam a apresentar tensão 1,7 vezes maior que os ovais. Ainda para os casos D, as raízes de seção transversal circular tiveram smax 1,3 vezes maior que as de seção transversal oval, mantendo o pino sempre circular. Já para os casos A, os valores foram muito semelhantes (embora, em geral, um pouco maiores) aos do dente hígido. O maior risco de descolamento foi detectado entre pino metálico fundido e cimento. O risco de fraturar a raiz foi maior em pinos descolados com pino metálico. Em raízes restauradas com pino de fibra, o maior risco de fratura ocorreu no núcleo e no pino, embora o valor do índice de risco de fratura seja muito mais alto que para os dentes restaurados com pino metálico. / The restoration of teeth with a large tissue destruction and endodontic treatment still presents a challenge for clinicians. The most critical failure after this type of treatment is the root fracture, with more incidence for upper premolars. The mesial-distal flattening of the root canal of these teeth and the detachment of the oval post have been pointed out as main factors predisposed to this type of fracture. The hypothesis of this study is that the presence of posts increases the risk of failure when this happens concomitantly to its detachment at the post/cement interface. This risk would be greater for cases in which the post follows the typical oval shape of the upper second premolar root canal. The objective of this study was to compare, by finite element analysis, the reply of the maximum principal stress (smax) for models which simulated posts with circular or oval cross-section, bonded or detached and for intact teeth models with circular or oval root canal. The risk of post/cement interface detachment was also evaluated. Two 3D models of an intact upper premolar, one with an oval canal (Ho) and other with a circular one (Hc) were obtained. From these models, other ones were obtained with glass fiber intra-radicular post and with cast core. For oval canals (Co), posts could presented circular (Pc) or oval (Po) crosssections, while for circular ones (Cc), only circular posts were simulated. All materials were considered homogeneous, linear and isotropic, except the glass fiber post which was considered orthotropic. For each model, a perfect bonding condition was simulated (A) and another with total detachment (D) between the post and the cement. A 300 N load was applied at 45° on the central-internal edge of the buccal cusp (centric loading) or diverted from 1,4 mm through the mesial (excentric loading). All different models were compared on stress distribution of smax and magnitude, and also smax peak vectors localization, and orientation at the dentin. The post/cement interface risk of detachment and the risk of fracture for posts, core and cement were analyzed. The tension peak for D cases was up to 4,7 times greater than that found for intact teeth and for A cases. For D cases, circular posts sometimes presented up to 1,7 times greater than oval ones. Further for D cases, roots with circular crosssectional had the smax 1,3 times greater than those with oval cross-sectional, with the post always circular. For A cases, values were however much similar (even though, in general, they were a little greater) to intact ones. The major risk of detachment was detected between the metallic post and the cement. The risk of root fracture is greater for detached posts with metallic posts. For restored roots with fiber posts, the major risk of fracture occurs to the core and the post, even the risk of fracture index is much greater than for restored teeth with metallic post.

Page generated in 0.0687 seconds