• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • Tagged with
  • 12
  • 9
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Efeito de terapia fotodinâmica utilizando curcumina como fotossensibilizante sobre o biofilme de S. gordonii formado sobre superfícies lisa e rugosa de titânio / Effect of photodynamic therapy using curcumin as a photosensitizer on the S. gordonii biofilm formed on smooth and rough surfaces of titanium

Flavia Luiza Rancan 13 March 2017 (has links)
A prevenção das doenças periimplantares baseia-se em procedimentos de rotina na clínica, com a remoção mecânica do biofilme associada ou não de agentes antimicrobianos locais e sistêmicos. No entanto, o controle do biofilme oral sobre a superfície de implantes é dificultado particularmente sobre as superfícies rugosas do titânio, que apesar de facilitarem a osseointegração, também favorecem a formação do biofilme. Objetivos: Objetivou-se analisar in vitro o efeito da TFD (Terapia fotodinâmica) usando curcumina como fotossensibilizador sobre o biofilme formado na superfície de discos de titânio com superfície rugosa e lisa. Material e Métodos: Biofilme mono espécie de Streptococus gordonii, colonizador inicial do biofilme dental, foi formado em superfícies lisas (usinadas) e rugosas (tratadas) de discos de titânio por 72 horas. Os discos lisos e rugosos foram então distribuídos em 3 grupos: tratados por 5 minutos com curcumina (60?M), clorexidina 0,12% como controle positivo e solução de DMSO (dimetilsufóxido), etanol e água como controle negativo (veículo da curcumina). As amostras foram divididas em 2 sub-grupos: ativado por LED azul (455-492nm) por 7 minutos e não-ativado. A atividade metabólica do biofilme foi determinada pelo método de redução do Sal tetralisol XTT e os resultados analisados estatisticamente pela análise da variância (ANOVA) seguida pelo teste de Tukey (p < 0,05). Resultados: Na ausência de luz, apenas o tratamento com clorexidina promoveu redução microbiana (controle positivo). O tratamento com curcumina ativada pela luz azul reduziu o número de bactérias viáveis no biofilme em 71% nos discos lisos e em 77% nos rugosos, não havendo diferença estatística com o controlepositivo.Conclusão: Os dados in vitro indicam que TFD associada à curcumina tem atividade sobre biofilme microbiano, sugerindo seu potencial no controle do biofilme oral sobre a superfície de titânio, e que este efeito independe da topografia da superfície. / Prevention of periimplant diseases is based on routine procedures in the clinic, with the mechanical removal of biofilm associated or not with local and systemic antimicrobial agents. However, the control of oral biofilm on the surface of implants is particularly difficult on the rough surfaces of titanium, which, although facilitating osseointegration, also favors biofilm formation. Objectives: The objective of this study was to analyze in vitro the effect of PDT using curcumin as a photosensitizer on the biofilm formed on the surface of titanium discs with a rough and smooth surface. Material and Methods: Biofilm mono species of Streptococus gordonii, initial colonizer of the dental biofilm, was formed on smooth (machined) and rough (treated) surfaces of titanium discs for 72 hours. The smooth and rough discs were then divided into 3 groups: treated for 5 minutes with curcumin (60 ?M), 0.1% chlorhexidine as a positive control and DMSO, ethanol and water solution as a negative control. The samples were divided into 2 subgroups: activated by blue LED (455-492nm) for 7 minutes and non-activated. The metabolic activity of the biofilm was determined by the reduction XTT salt method and the results analyzed statistically by ANOVA followed by the Tukey\'s test (p <0.05) Results: In the absence of light, only the chlorhexidine treatment promoted microbial reduction (positive control). The blue light-activated curcumin treatment reduced the number of viable bacteria in the biofilm in 71% in the smooth discs and in 77% in the wrinkles, and there was no statistical difference with the positive control. Conclusion: In vitro data indicate that PDT associated with curcumin has activity on microbial biofilm, suggesting its potential in the control of oral biofilm on the titanium surface, and that this effect is independent of surface topography.
Read more
12

Exatidão de filtros de imagem na avaliação radiográfica do nível ósseo peri-implantar / Accuracy of enhancement filters in measuring in-vitro periimplant bone level

Vaz, Sergio Lins de Azevedo, 1984- 20 August 2018 (has links)
Orientador: Paulo Sérgio Flores Campos / Texto do capítulo 1 em inglês / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-20T12:07:20Z (GMT). No. of bitstreams: 1 Vaz_SergioLinsdeAzevedo_M.pdf: 1201820 bytes, checksum: c01a9a7bcc2ca60b934986c91f46e192 (MD5) Previous issue date: 2012 / Resumo: O objetivo neste trabalho foi identificar a exatidão de alguns filtros de imagem na mensuração do nível ósseo peri-implantar, por meio da radiografia digital. Para isso, vinte implantes de titânio (Titamax, Neodent, Curitiba, PR, Brasil) foram instalados em seis fragmentos de costelas bovinas, nas quais foram criados defeitos do tipo perda óssea. Utilizando um sistema intra-bucal de placas de fósforo (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Alemanha), radiografias periapicais foram realizadas posicionando os implantes segundo a técnica do paralelismo. Após a obtenção das imagens, nove filtros do software DBSWIN foram aplicados: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss e sculpture. Um avaliador mensurou as distâncias entre o ombro do implante à porção mais apical do defeito no software Image J. Os defeitos também foram mensurados nas costelas bovinas utilizando um paquímetro digital. O teste não-paramétrico de Friedman comparou os valores obtidos nas imagens com aplicação dos filtros aos encontrados nas imagens originais e nas costelas bovinas, adotando nível de significância de 5%. Os resultados mostraram diferenças estatisticamente significantes para os filtros caries1, caries2, endo e perio (P < 0.05) tanto em relação às imagens originais, quanto em relação às mensurações obtidas com o paquímetro. As mensurações obtidas com as imagens originais, filtros fine e emboss foram mais próximas às obtidas com o paquímetro. Concluiu-se que os filtros fine e emboss foram os mais exatos na mensuração do nível ósseo peri-implantar, sendo equiparáveis às imagens originais. Os filtros caries1, caries2, endo e perio foram os menos exatos, não sendo indicados para este fim / Abstract: This study aimed to identify the accuracy of some enhancement filters of an intraoral phosphor-plate system for measuring the simulated periimplant bone level. Twenty titanium implants (Titamax, Neodent, Curitiba, PR, Brazil) were placed into six fragments of bovine ribs and defects simulating bone loss were created. Periapical radiographs were taken with a phosphor-plate system (Vista Scan, Dürr Dental, Beitigheim-Bissingen, Germany) according to the paralleling standard technique, and nine enhancement filters were applied: fine, caries 1, caries 2, perio, endo, noise reduction, invert, emboss and sculpture. An oral radiologist measured on the Image J software the distance from the neck of the implant to the most apical contact of the bone with the implant. The Friedman non-parametric test compared the radiographic measurements to those obtained on the bovine ribs with a digital caliper. The significance level adopted was 5%. The caries1, caries2, endo, and perio filters resulted on measurements statistically different from both the original images and the measures of the digital caliper (P < 0.05). In conclusion, the fine and emboss filters resulted on the most precise filters, with similar measures to the original images. The caries1, caries2, endo, and perio filters were the less accurate for measuring the periimplant bone level / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica
Read more

Page generated in 0.0515 seconds