• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 12
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 19
  • 9
  • 9
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação dos efeitos de diferentes agentes condicionadores na descontaminação da superfície de titânio: estudo in vitro / Evaluation of the effects of different conditioning agents in the decontamination of the implant surface: in vitro study

Barros, João Paulo Corrêa 14 March 2016 (has links)
O uso de implantes osseointegrados vem crescendo nas últimas décadas e, juntamente com eles, suas complicações. A periimplantite se apresenta como uma infecção bacteriana que afeta os tecidos moles e duros ao redor do implante, promovendo perda da osseointegração. Assim, o objetivo primário deste estudo foi analisar a efetividade da remoção de bactérias, através do software ImageJ, aderidas às superfícies de titânio por diferentes agentes químicos condicionantes, por meio de análise em microscopia eletrônica de varredura (MEV). Juntamente foi analisado a alteração da rugosidade de superfície após a utilização dos agentes. Foi realizado estudo in vitro, no qual 70 covers (protótipos de implantes) passaram por preparo das superfícies para adequação do meio à cultura bacteriana, fixação das bactérias; e em seguida, foram divididos em 7 grupos (n=10), de acordo com o tratamento: AF180 aplicação de ácido fosfórico (AF) por 180 segundos; AF90- AF por 90 segundos; EDTA180 EDTA por 180 segundos; EDTA90 EDTA por 90 segundos; AC180 ácido cítrico por 180 segundos; AC90 AC por 90 segundos; Controle RAR. A análise comparativa do grau de contaminação bacteriana observado antes e depois do tratamento entre os diferentes grupos foi realizada por meio do teste não paramétrico de Kruskal-Wallis; e as alterações da rugosidade superficial foram analisadas por meio do teste ANOVA a dois critérios, pós-teste de Dunnett. Através desta metodologia, este trabalho sugere que o tratamento de superfícies de titânio contaminadas por meio do emprego de solução em gel de EDTA a 24% por 90 e 180 segundos e ácido cítrico a 50% por 180 segundos é efetiva para remoção de A. atinomycetencomitans. Além disso, o tratamento por meio de EDTA por 90 e 180 segundos promove alteração significativa dos parâmetros de rugosidade superficial, especialmente quando comparado aos grupos controle e AF180, indicando que este tratamento pode resultar em subtração ácida adicional. / The use of dental implants has grown in recent decades and, with them, their complications. The periimplantitis is presented as a bacterial infection that affects the soft and hard tissue around the implant, promoting loss of osseointegration. Thus, the primary objective of this study was to analyze the effectiveness of removal of bacteria tby means of the ImageJ software, adhered to the titanium surfaces by different chemical conditions, through analysis in scanning electron microscopy (SEM). The change of surface roughness was also analyzed after using the chemical agents. An in vitro study in which 70 covers (implant prototypes) was prepared for the bacteria culture, fixation of the bacterias; and then they were divided into 7 groups (n = 10), according to the surface treatment: AF180- application of phosphoric acid (FA) for 180 seconds; AF90- AF for 90 seconds; EDTA180 - EDTA for 180 seconds; EDTA90 - EDTA for 90 seconds; AC180 - citric acid for 180 seconds; AC90 -AC for 90 seconds; Control - RAR. The comparative analysis of the degree of bacterial contamination was performed using Kruskal-Wallis non parametric test; and changes of surface roughness were analyzed by ANOVA two criteria, post-test Dunnett. Through this method, this work suggests that treatment of titanium contaminated surfaces by means of EDTA gel solution employing 24% for 90 and 180 seconds and citric acid 50% for 180 seconds is effective for removing A. atinomycetencomitans. Moreover, treatment using EDTA for 90 to 180 seconds promotes significant change of surface roughness parameters, especially when compared to control groups and AF180, indicating that this treatment can result in additional acidic subtraction.
2

Avaliação in vitro da microinfiltração bacteriana em implantes do tipo hexágono externo, hexágono interno e cone morse / Evaluation in vitro of bacterial microleakage in external hexagonal, internal hexagonal and morse-taper dental implants

Pimentel, Gustavo Henrique Diniz 01 July 2009 (has links)
Três dos principais tipos de implantes disponíveis no mercado são: o hexágono externo, o hexágono interno e o cone morse. Um microespaço, presente entre o implante e o intermediário protético, permite a penetração bacteriana e colonização do interior do implante. Esse microespaço, juntamente com a colonização bacteriana, tem sido associado com a perda óssea ao redor dos implantes, característica da periimplantite. O objetivo desse trabalho foi comparar a possível contaminação bacteriana nesses três tipos de implantes, em um período de 24 horas, semelhante ao que acontece na condição de carga imediata. Para tal, foram utilizados 10 implantes de cada tipo, com seus respectivos intermediários protéticos, sendo o Grupo 1 de implantes Hexágono Externo (HE), Grupo 2 de Hexágono Interno (HI) e Grupo 3 de Cone Morse (CM). No interior de cada implante foram inoculados 2L de meio de cultura (BHI). Os espécimes foram depositados individualmente em tubos de ensaio contendo 4 mL de BHI estéril. Após um teste de esterilidade, 100L de BHI contendo Enterococcus faecalis foram inoculados em cada tubo. Após 24 horas em meio contendo bactérias, os espécimes foram removidos, desinfectados e reabertos. Com um cone de papel estéril, o material do interior dos implantes foi coletado e colocado em meio de cultura para avaliar a possível passagem de bactérias do meio externo para o interno dos implantes. O teste foi repetido por mais duas vezes (Teste I, II e III), com o cuidado de se lavar e esterilizar em autoclave os espécimes. Os resultados foram tabulados e o teste exato de Fisher foi aplicado com o nível de significância de 5%. Os resultados do teste I mostraram a contaminação de 8 implantes HE, 4 implantes HI e 2 implantes CM, sendo a contaminação no grupo HE estatisticamente significante maior que nos grupos HI e CM; o teste II mostrou a contaminação de 7 implantes HE, 4 implantes HI e 4 implantes CM, não havendo diferenças estatisticamente significantes; o teste III mostrou a contaminação de 10 implantes HE, 7 implantes HI e 3 implantes CM, revelando diferenças estatisticamente significantes entre o grupo HE e CM. Concluise, portanto, que após um período de 24 horas, houve contaminação bacteriana em todos os grupos avaliados, sendo estatisticamente maior no grupo 1. / Three main types of implants available in the market are: external hexagonal, internal hexagonal and morse-taper. A microgap, present between the implant and the abutment, enables bacterial penetration and colonization of the interior of the implant. This microgap, associated with bacterial colonization, has been related with bone loss around the implants, present in periimplantitis . The aim of this study was to compare the possible bacterial contamination in these three types of implants in a 24 hour period, similarly with immediate loading. 10 implants of each type, with their abutments, were used. The implants of Group 1 were external hexagonal (HE) type, Group 2 were Internal Hexagonal (HI) type and Group 3, morse-taper type(MC). 2 µL of brain-heart infusion (BHI) broth were added into each implant. The specimens were placed individually in glass culture tubes containing 4 mL of sterile BHI broth. After a test to assure sterility, 100 µL of BHI broth containing Enterococcus faecalis were inoculated in each tube. After 24 hours, the specimens were removed, disinfected and reopened. With a sterile paper cone, the material inside the implants were collected and placed in BHI to evaluate the possible passage of bacteria from the outside to the internal side of the implant. The test was repeated two times more (Test I, II and III). The Fisher exact test was used to compare the number of contaminated implants in each group, at a significance level of 5%. The results of test I showed contamination of 8 HE implants, 4 HI implants and 2 CM implants. The contamination in the HE group was statistically higher than CM and HI groups. Test II revealed contamination of 7 HE implants, 4 HI implants and 4 CM implants. No statistically significant differences were observed. Test III showed contamination of 10 HE implants, 7 HI implants and 3 CM implants, revealing statistically significant differences between HE and CM groups. It can be concluded that after a period of 24 hours, there was bacterial leakage in all groups studied, with statistically higher contamination in group 1.
3

Avaliação dos efeitos de diferentes agentes condicionadores na descontaminação da superfície de titânio: estudo in vitro / Evaluation of the effects of different conditioning agents in the decontamination of the implant surface: in vitro study

João Paulo Corrêa Barros 14 March 2016 (has links)
O uso de implantes osseointegrados vem crescendo nas últimas décadas e, juntamente com eles, suas complicações. A periimplantite se apresenta como uma infecção bacteriana que afeta os tecidos moles e duros ao redor do implante, promovendo perda da osseointegração. Assim, o objetivo primário deste estudo foi analisar a efetividade da remoção de bactérias, através do software ImageJ, aderidas às superfícies de titânio por diferentes agentes químicos condicionantes, por meio de análise em microscopia eletrônica de varredura (MEV). Juntamente foi analisado a alteração da rugosidade de superfície após a utilização dos agentes. Foi realizado estudo in vitro, no qual 70 covers (protótipos de implantes) passaram por preparo das superfícies para adequação do meio à cultura bacteriana, fixação das bactérias; e em seguida, foram divididos em 7 grupos (n=10), de acordo com o tratamento: AF180 aplicação de ácido fosfórico (AF) por 180 segundos; AF90- AF por 90 segundos; EDTA180 EDTA por 180 segundos; EDTA90 EDTA por 90 segundos; AC180 ácido cítrico por 180 segundos; AC90 AC por 90 segundos; Controle RAR. A análise comparativa do grau de contaminação bacteriana observado antes e depois do tratamento entre os diferentes grupos foi realizada por meio do teste não paramétrico de Kruskal-Wallis; e as alterações da rugosidade superficial foram analisadas por meio do teste ANOVA a dois critérios, pós-teste de Dunnett. Através desta metodologia, este trabalho sugere que o tratamento de superfícies de titânio contaminadas por meio do emprego de solução em gel de EDTA a 24% por 90 e 180 segundos e ácido cítrico a 50% por 180 segundos é efetiva para remoção de A. atinomycetencomitans. Além disso, o tratamento por meio de EDTA por 90 e 180 segundos promove alteração significativa dos parâmetros de rugosidade superficial, especialmente quando comparado aos grupos controle e AF180, indicando que este tratamento pode resultar em subtração ácida adicional. / The use of dental implants has grown in recent decades and, with them, their complications. The periimplantitis is presented as a bacterial infection that affects the soft and hard tissue around the implant, promoting loss of osseointegration. Thus, the primary objective of this study was to analyze the effectiveness of removal of bacteria tby means of the ImageJ software, adhered to the titanium surfaces by different chemical conditions, through analysis in scanning electron microscopy (SEM). The change of surface roughness was also analyzed after using the chemical agents. An in vitro study in which 70 covers (implant prototypes) was prepared for the bacteria culture, fixation of the bacterias; and then they were divided into 7 groups (n = 10), according to the surface treatment: AF180- application of phosphoric acid (FA) for 180 seconds; AF90- AF for 90 seconds; EDTA180 - EDTA for 180 seconds; EDTA90 - EDTA for 90 seconds; AC180 - citric acid for 180 seconds; AC90 -AC for 90 seconds; Control - RAR. The comparative analysis of the degree of bacterial contamination was performed using Kruskal-Wallis non parametric test; and changes of surface roughness were analyzed by ANOVA two criteria, post-test Dunnett. Through this method, this work suggests that treatment of titanium contaminated surfaces by means of EDTA gel solution employing 24% for 90 and 180 seconds and citric acid 50% for 180 seconds is effective for removing A. atinomycetencomitans. Moreover, treatment using EDTA for 90 to 180 seconds promotes significant change of surface roughness parameters, especially when compared to control groups and AF180, indicating that this treatment can result in additional acidic subtraction.
4

Avaliação in vitro da microinfiltração bacteriana em implantes do tipo hexágono externo, hexágono interno e cone morse / Evaluation in vitro of bacterial microleakage in external hexagonal, internal hexagonal and morse-taper dental implants

Gustavo Henrique Diniz Pimentel 01 July 2009 (has links)
Três dos principais tipos de implantes disponíveis no mercado são: o hexágono externo, o hexágono interno e o cone morse. Um microespaço, presente entre o implante e o intermediário protético, permite a penetração bacteriana e colonização do interior do implante. Esse microespaço, juntamente com a colonização bacteriana, tem sido associado com a perda óssea ao redor dos implantes, característica da periimplantite. O objetivo desse trabalho foi comparar a possível contaminação bacteriana nesses três tipos de implantes, em um período de 24 horas, semelhante ao que acontece na condição de carga imediata. Para tal, foram utilizados 10 implantes de cada tipo, com seus respectivos intermediários protéticos, sendo o Grupo 1 de implantes Hexágono Externo (HE), Grupo 2 de Hexágono Interno (HI) e Grupo 3 de Cone Morse (CM). No interior de cada implante foram inoculados 2L de meio de cultura (BHI). Os espécimes foram depositados individualmente em tubos de ensaio contendo 4 mL de BHI estéril. Após um teste de esterilidade, 100L de BHI contendo Enterococcus faecalis foram inoculados em cada tubo. Após 24 horas em meio contendo bactérias, os espécimes foram removidos, desinfectados e reabertos. Com um cone de papel estéril, o material do interior dos implantes foi coletado e colocado em meio de cultura para avaliar a possível passagem de bactérias do meio externo para o interno dos implantes. O teste foi repetido por mais duas vezes (Teste I, II e III), com o cuidado de se lavar e esterilizar em autoclave os espécimes. Os resultados foram tabulados e o teste exato de Fisher foi aplicado com o nível de significância de 5%. Os resultados do teste I mostraram a contaminação de 8 implantes HE, 4 implantes HI e 2 implantes CM, sendo a contaminação no grupo HE estatisticamente significante maior que nos grupos HI e CM; o teste II mostrou a contaminação de 7 implantes HE, 4 implantes HI e 4 implantes CM, não havendo diferenças estatisticamente significantes; o teste III mostrou a contaminação de 10 implantes HE, 7 implantes HI e 3 implantes CM, revelando diferenças estatisticamente significantes entre o grupo HE e CM. Concluise, portanto, que após um período de 24 horas, houve contaminação bacteriana em todos os grupos avaliados, sendo estatisticamente maior no grupo 1. / Three main types of implants available in the market are: external hexagonal, internal hexagonal and morse-taper. A microgap, present between the implant and the abutment, enables bacterial penetration and colonization of the interior of the implant. This microgap, associated with bacterial colonization, has been related with bone loss around the implants, present in periimplantitis . The aim of this study was to compare the possible bacterial contamination in these three types of implants in a 24 hour period, similarly with immediate loading. 10 implants of each type, with their abutments, were used. The implants of Group 1 were external hexagonal (HE) type, Group 2 were Internal Hexagonal (HI) type and Group 3, morse-taper type(MC). 2 µL of brain-heart infusion (BHI) broth were added into each implant. The specimens were placed individually in glass culture tubes containing 4 mL of sterile BHI broth. After a test to assure sterility, 100 µL of BHI broth containing Enterococcus faecalis were inoculated in each tube. After 24 hours, the specimens were removed, disinfected and reopened. With a sterile paper cone, the material inside the implants were collected and placed in BHI to evaluate the possible passage of bacteria from the outside to the internal side of the implant. The test was repeated two times more (Test I, II and III). The Fisher exact test was used to compare the number of contaminated implants in each group, at a significance level of 5%. The results of test I showed contamination of 8 HE implants, 4 HI implants and 2 CM implants. The contamination in the HE group was statistically higher than CM and HI groups. Test II revealed contamination of 7 HE implants, 4 HI implants and 4 CM implants. No statistically significant differences were observed. Test III showed contamination of 10 HE implants, 7 HI implants and 3 CM implants, revealing statistically significant differences between HE and CM groups. It can be concluded that after a period of 24 hours, there was bacterial leakage in all groups studied, with statistically higher contamination in group 1.
5

Retrospektive Untersuchung zu implantatverankerten Ohrepithesen

Guo, Gao 03 May 2005 (has links)
Das Ziel dieser Arbeit war es, das klinische Resultat der implantatverankerten Ohrepithese retrospektiv zu untersuchen. Es wurden die Daten von 46 Patienten erhoben, die von 1992 bis 2003 mit implantatverankerten Ohrepithesen versorgt wurden. Bei 20 Patienten mit 53 Implantaten wurde eine spezielle Nachuntersuchung zur Beurteilung der periimplantären Weichgewebssituation durchgeführt. Zwei objektive klinische Parameter, die Sondierungstiefe und die Sulcus Fluid Flow Rate (SFFR), wurden hierfür angewendet. Die subjektive Beurteilung der Hautreaktionen war durch das Graduierungsystem von Holgers klassifiziert. 24 Patienten wurden mit Hilfe eines einheitlichen Fragebogens über die Zufriedenheit und auf mögliche Beschwerden befragt. Die kongenitalen Ohrmissbildungen (62,5%) waren die häufigsten Indikationen bei dieser Behandlung. 156 Implantate und eine Trägerplatte (Epitec-System®) bei den 46 Patienten inseriert, darunter waren 23 Implantate aus dem EO-System®, sowie 133 aus dem Brånemark-System®. Intraoperative Komplikationen traten bei der Implantatinsertion nicht auf. Die Implantationserfolgsrate liegt bei 100%. Bei 34 Patienten (74%) wurden insgesamt 42-mal Hautreaktionen (Entzündungen, Blutungen, Schwellungen) während der Nachkontrolle registriert. Die durchschnittliche Tragezeit der Ohrepithesen betrug 2,7 Jahre. Periimplantäre Hauttaschen sind in unserer Studie bei allen untersuchten Implantaten beobachtet worden. In der speziellen Nachuntersuchung lag der mittlere Wert der Sondierungstiefe und der SFFR bei 2,1 mm bzw. 1,8 mm. Zwischen beiden Parameter wurde eine starke Korrelation festgestellt: Je tiefer die Sondierungstiefe desto höher waren die Werte der SFFR. Bei 22 Implantaten (41,5%) ergaben sich keine Hautreaktionen. Die Entzündungen wurden nur an vier Implantaten (7,5%) beobachtet. 91,7% der befragten Patienten waren mit ihrer Ohrepithese zufrieden. Anhand unserer Studie, dass die implantatverankerten Ohrepithese heute ausgezeichnete und stabile Langzeitergebnisse erzielt werden können. Die tiefe Hauttasche spricht für ein Zeichen der periimplantären Entzündung und eine Notwendigkeit einer periimplantäreren Hautausdünnung. / The purpose of this study is to retrospectively evaluate the clinical results of the implant-retained auricular prosthesis. The data of 46 patients who were treated between 1992 and 2003 with implant-retained auricular prosthesis were evaluated. 20 patients with 53 implants were re-examined to evaluate the periimplant soft tissue situation with two objective clinical parameters periimplant sulcus probing depth and sulcus-fluid-flow-rate (SFFR). The subjective evalution of skin reactions around the abutments was classified as reported by Holgers. Satisfaction and eventual complications were evaluated in 24 patients by using standardized Questionnaires. Congenital malformation (62.5%) was the most common indications for auricular prostheses. A total of 156 implants and a plate (Epitec-System®) were placed in 46 patients, 23 of which were EO-System®, and 133 were Brånemark-System®. No intraoperative complications were reported during the insertion of implants. The implant survival rate was 100%. 42 times of skin reactions (inflammation, bleeding, swelling) were registered in 34 patients. The average wearing time of the prosthesis was 2.7 year. Skin pockets were found in all of the 53 re-examined implants. The middle value of sulcus probing depth and SFFR was respectively 2.1 mm and 1.8 mm. A strong correlation was found between the two parameter, which suggests that a deeper sulcus always presents a high value of SFFR. No adverse skin reactions was found in 22 implants (41.5%). Severe inflammation was observed in only 4 implants (7.5%). 91,7% of patients were satisfied with their prostheses. From this study it can be concluded that the implant-retained auricular prostheses offer a good and secure perspective for patients. The deep sulcus shows a sign of periimplantitis and a surgical thinning of subcutaneous periimplant soft tissue should be perfomed to eliminate it.
6

Aplicación de un termómetro auditivo infrarrojo en la evaluación de la salud periimplantaria

Moya Villaescusa, Maria José 26 February 2005 (has links)
Introducción: En la actualidad, no existe un protocolo universalmente aceptado para la evaluación clínica de los implantes dentales, siendo la mayoría de ellos de naturaleza tardía.Objetivo: Establecer el patrón de normalidad de la temperatura periimplantar, para introducir un método objetivo de diagnóstico precoz implantológico.Material y métodos: Se incluyeron en el estudio un total de 129 implantes osteointegrados, protésicamente restaurados, y clínicamente sanos, los cuales fueron sometidos a una exploración térmica, clínica y radiográfica.Resultados: Tras aplicar un análisis de conglomerados a la muestra, obtuvimos dos grupos diferenciados estadísticamente, tanto desde el punto de vista del diferencial de temperatura, como desde el de la temperatura periimplantaria.Conclusión: El patrón de normalidad de la temperatura periimplantar va a depender de la localización anatómica del implante en la arcada, pudiendo distinguirse entre una región fría (segundo y tercer sextante) y una región cálida (mandíbula y primer sextante). / Introduction: Nowadays, it does not exist a protocol universally accepted for the clinical evaluation of dental implants, being most of them of late nature. Objetive: to establish a pattern of normality of the periimplant temperature, to introduce an objective method of implantology precocious diagnostic.Material and methods: They were included in the study 129 osteointegrated, restored and clinically healthy. These implants were explored thermally, clinically and radiographically.Results: After applying an analysis of conglomerates to the sample, we obtained two groups differed statistically, so much from the point of view of the differential of temperature, as from the periimplant temperature. Conclusions: The pattern of normality of the periimplant temperature will depend on the anatomical localization of the implant in the arcade, being able to be distinguished among a cold region (formed by the second and third sextant) and a warm region (composed by mandible region and the first sextant).
7

Efeito de terapia fotodinâmica utilizando curcumina como fotossensibilizante sobre o biofilme de S. gordonii formado sobre superfícies lisa e rugosa de titânio / Effect of photodynamic therapy using curcumin as a photosensitizer on the S. gordonii biofilm formed on smooth and rough surfaces of titanium

Rancan, Flavia Luiza 13 March 2017 (has links)
A prevenção das doenças periimplantares baseia-se em procedimentos de rotina na clínica, com a remoção mecânica do biofilme associada ou não de agentes antimicrobianos locais e sistêmicos. No entanto, o controle do biofilme oral sobre a superfície de implantes é dificultado particularmente sobre as superfícies rugosas do titânio, que apesar de facilitarem a osseointegração, também favorecem a formação do biofilme. Objetivos: Objetivou-se analisar in vitro o efeito da TFD (Terapia fotodinâmica) usando curcumina como fotossensibilizador sobre o biofilme formado na superfície de discos de titânio com superfície rugosa e lisa. Material e Métodos: Biofilme mono espécie de Streptococus gordonii, colonizador inicial do biofilme dental, foi formado em superfícies lisas (usinadas) e rugosas (tratadas) de discos de titânio por 72 horas. Os discos lisos e rugosos foram então distribuídos em 3 grupos: tratados por 5 minutos com curcumina (60?M), clorexidina 0,12% como controle positivo e solução de DMSO (dimetilsufóxido), etanol e água como controle negativo (veículo da curcumina). As amostras foram divididas em 2 sub-grupos: ativado por LED azul (455-492nm) por 7 minutos e não-ativado. A atividade metabólica do biofilme foi determinada pelo método de redução do Sal tetralisol XTT e os resultados analisados estatisticamente pela análise da variância (ANOVA) seguida pelo teste de Tukey (p < 0,05). Resultados: Na ausência de luz, apenas o tratamento com clorexidina promoveu redução microbiana (controle positivo). O tratamento com curcumina ativada pela luz azul reduziu o número de bactérias viáveis no biofilme em 71% nos discos lisos e em 77% nos rugosos, não havendo diferença estatística com o controlepositivo.Conclusão: Os dados in vitro indicam que TFD associada à curcumina tem atividade sobre biofilme microbiano, sugerindo seu potencial no controle do biofilme oral sobre a superfície de titânio, e que este efeito independe da topografia da superfície. / Prevention of periimplant diseases is based on routine procedures in the clinic, with the mechanical removal of biofilm associated or not with local and systemic antimicrobial agents. However, the control of oral biofilm on the surface of implants is particularly difficult on the rough surfaces of titanium, which, although facilitating osseointegration, also favors biofilm formation. Objectives: The objective of this study was to analyze in vitro the effect of PDT using curcumin as a photosensitizer on the biofilm formed on the surface of titanium discs with a rough and smooth surface. Material and Methods: Biofilm mono species of Streptococus gordonii, initial colonizer of the dental biofilm, was formed on smooth (machined) and rough (treated) surfaces of titanium discs for 72 hours. The smooth and rough discs were then divided into 3 groups: treated for 5 minutes with curcumin (60 ?M), 0.1% chlorhexidine as a positive control and DMSO, ethanol and water solution as a negative control. The samples were divided into 2 subgroups: activated by blue LED (455-492nm) for 7 minutes and non-activated. The metabolic activity of the biofilm was determined by the reduction XTT salt method and the results analyzed statistically by ANOVA followed by the Tukey\'s test (p <0.05) Results: In the absence of light, only the chlorhexidine treatment promoted microbial reduction (positive control). The blue light-activated curcumin treatment reduced the number of viable bacteria in the biofilm in 71% in the smooth discs and in 77% in the wrinkles, and there was no statistical difference with the positive control. Conclusion: In vitro data indicate that PDT associated with curcumin has activity on microbial biofilm, suggesting its potential in the control of oral biofilm on the titanium surface, and that this effect is independent of surface topography.
8

Comparação entre dois métodos de descontaminação da superfície de implantes na re-osseointegração após a periimplantite induzida por ligadura. Estudo histomorfométrico e microbiológico em cães / Comparison of two implant surface decontamination protocols on reosseointegration of induced perimplantitis in beagle dogs. A microbiologic an histomorphometric study

Ramos, Umberto Demoner 29 July 2016 (has links)
Introdução: A doença periimplantar caracteriza-se pela perda óssea progressiva em implantes dentais osseointegrados. Sua origem é bacteriana, e acomete cerca de 20% da população com reabilitações implantossuportadas. O sucesso do tratamento parece depender da desinfecção da superfície dos implantes para resolução da inflamação, e da configuração dos defeitos ósseos para a regeneração dos tecidos. Até o momento, não há protocolos bem estabelecidos para a desinfecção da superfície de implantes osseointegrados. O objetivo deste estudo foi comparar dois métodos de desinfecção da superfície de implantes, e o efeito do uso da regeneração óssea guiada no tratamento da periimplantite induzida em cães. Materiais e Método: Oito cães beagle receberam 8 implantes cada. Após 8 semanas, ligaduras de seda foram posicionadas, e removidas após mais 8 semanas. O tratamento foi realizado após 10 semanas, por meio de desinfecção com a terapia fotodinâmica antimicrobiana ou aplicação tópica tetraciclina 50mg/ml, com ou sem procedimentos de regeneração óssea guiada associados. Durante o tratamento foram coletadas amostras microbiológicas por meio de um swab com microbrush estéril antes do tratamento, e imediatamente após o tratamento. A eutanásia ocorreu 12 semanas após o tratamento para processamento histológico. Os desfechos de tratamento analisados foram: ganho ósseo linear (mm), ganho ósseo (%), reosseointegração (%), redução bacteriana total e proporcional após o tratamento (%). Resultados: Os resultados gerais não demonstraram diferenças significantes entre os grupos quando comparados os métodos de desinfecção, e o uso ou não de procedimentos regenerativos. O uso da regeneração óssea guiada não resultou em melhoras no ganho ósseo, e sítios vestibulares apresentaram piores resultados regenerativos. A exposição precoce ao meio bucal afetou negativamente os resultados do tratamento, independente do grupo. Conclusão: Ambas terapias antiinfecciosas, associadas ou não a procedimentos regenerativos, obtiveram sucesso na resolução da inflamação e desinfecção da superfície dos implantes, com ganho ósseo parcial, sem o uso de antibioticoterapia sistêmica. / Objectives: This study used a dog model to evaluate two anti-infective treatment protocols for the treatment of periimplantitis with or without the use of guided bone regeneration (GBR). Material and Methods: Eight beagle dogs received eight implants each. After 8 weeks, silk ligatures were installed and then removed after 8 weeks, and after the end of 10 weeks the lesions were treated either with antimicrobial photodynamic therapy (aPDT) or topical tetracycline hydrochloride 50mg/ml with and without guided bone regeneration. Microbiological samples were collected with sterile microbrush before, and immediately after treatment. The animals were euthanized 12 weeks after treatment and submitted to histological processing. The outcomes evaluated included: linear bone gain (mm), bone gain (%), re-osseointegration (%), bacteria total counts before and after each treatment, and proportions of microorganisms. The effects of the implant site, early exposure and type of anti-infective treatment on bone regeneration were evaluated. Results: Both treatment presented success on decontamination of implant surface, with no difference between them. The overall results failed to detect significant differences between the anti-infective treatments and the adjunctive use of guided bone regeneration failed provide better re-osseointegration or bone gain in either of the anti-infective treatments. Buccal sites and implant early exposure negatively affect bone regeneration. Conclusion: Both antiinfective therapies successfully decontaminated implant surface. Stand-alone or combined with guided bone regeneration allowed similar and partial bone gain, without the use of systemic antibiotics.
9

Comparação entre dois métodos de descontaminação da superfície de implantes na re-osseointegração após a periimplantite induzida por ligadura. Estudo histomorfométrico e microbiológico em cães / Comparison of two implant surface decontamination protocols on reosseointegration of induced perimplantitis in beagle dogs. A microbiologic an histomorphometric study

Umberto Demoner Ramos 29 July 2016 (has links)
Introdução: A doença periimplantar caracteriza-se pela perda óssea progressiva em implantes dentais osseointegrados. Sua origem é bacteriana, e acomete cerca de 20% da população com reabilitações implantossuportadas. O sucesso do tratamento parece depender da desinfecção da superfície dos implantes para resolução da inflamação, e da configuração dos defeitos ósseos para a regeneração dos tecidos. Até o momento, não há protocolos bem estabelecidos para a desinfecção da superfície de implantes osseointegrados. O objetivo deste estudo foi comparar dois métodos de desinfecção da superfície de implantes, e o efeito do uso da regeneração óssea guiada no tratamento da periimplantite induzida em cães. Materiais e Método: Oito cães beagle receberam 8 implantes cada. Após 8 semanas, ligaduras de seda foram posicionadas, e removidas após mais 8 semanas. O tratamento foi realizado após 10 semanas, por meio de desinfecção com a terapia fotodinâmica antimicrobiana ou aplicação tópica tetraciclina 50mg/ml, com ou sem procedimentos de regeneração óssea guiada associados. Durante o tratamento foram coletadas amostras microbiológicas por meio de um swab com microbrush estéril antes do tratamento, e imediatamente após o tratamento. A eutanásia ocorreu 12 semanas após o tratamento para processamento histológico. Os desfechos de tratamento analisados foram: ganho ósseo linear (mm), ganho ósseo (%), reosseointegração (%), redução bacteriana total e proporcional após o tratamento (%). Resultados: Os resultados gerais não demonstraram diferenças significantes entre os grupos quando comparados os métodos de desinfecção, e o uso ou não de procedimentos regenerativos. O uso da regeneração óssea guiada não resultou em melhoras no ganho ósseo, e sítios vestibulares apresentaram piores resultados regenerativos. A exposição precoce ao meio bucal afetou negativamente os resultados do tratamento, independente do grupo. Conclusão: Ambas terapias antiinfecciosas, associadas ou não a procedimentos regenerativos, obtiveram sucesso na resolução da inflamação e desinfecção da superfície dos implantes, com ganho ósseo parcial, sem o uso de antibioticoterapia sistêmica. / Objectives: This study used a dog model to evaluate two anti-infective treatment protocols for the treatment of periimplantitis with or without the use of guided bone regeneration (GBR). Material and Methods: Eight beagle dogs received eight implants each. After 8 weeks, silk ligatures were installed and then removed after 8 weeks, and after the end of 10 weeks the lesions were treated either with antimicrobial photodynamic therapy (aPDT) or topical tetracycline hydrochloride 50mg/ml with and without guided bone regeneration. Microbiological samples were collected with sterile microbrush before, and immediately after treatment. The animals were euthanized 12 weeks after treatment and submitted to histological processing. The outcomes evaluated included: linear bone gain (mm), bone gain (%), re-osseointegration (%), bacteria total counts before and after each treatment, and proportions of microorganisms. The effects of the implant site, early exposure and type of anti-infective treatment on bone regeneration were evaluated. Results: Both treatment presented success on decontamination of implant surface, with no difference between them. The overall results failed to detect significant differences between the anti-infective treatments and the adjunctive use of guided bone regeneration failed provide better re-osseointegration or bone gain in either of the anti-infective treatments. Buccal sites and implant early exposure negatively affect bone regeneration. Conclusion: Both antiinfective therapies successfully decontaminated implant surface. Stand-alone or combined with guided bone regeneration allowed similar and partial bone gain, without the use of systemic antibiotics.
10

Comparação dos tratamentos cirúrgico e não cirúrgico da perimplantite : análise clínica de 3 meses de um ensaio controlado randomizado

Costa, Ricardo dos Santos Araujo January 2017 (has links)
As doenças perimplantares (DPi) vêm sendo consideradas umas das maiores causas de perdas tardias de implantes dentários e nenhum dos tratamentos já propostos na literatura mostrou ser eficiente a ponto de se tornar a primeira escolha terapêutica. Considerando que a definição correta do tratamento depende invariavelmente do entendimento da etiopatogenia, ocorrências e diagnóstico das DPi, o objetivo da presente tese foi abordar as DPi através de uma ampla revisão dos seus conceitos e da apresentação de dados clínicos preliminares de três meses de um ensaio clínico controlado randomizado comparando os resultados dos tratamentos cirúrgico (C) e não cirúrgico (NC) da perimplantite. Foram incluídos implantes apresentando um ou mais sítios com profundidade de sondagem perimplantar (PSi) ≥ 5mm, com presença de sangramento submucoso (SSi) e/ou supuração e apresentando perda óssea radiográfica (PO) ≥ 3mm. O tratamento não cirúrgico incluiu debridamento mecânico com curetas de teflon e irrigação com solução salina, assim como o tratamento cirúrgico, com acesso por retalho mucoperiostal. Não foram utilizadas técnicas ressectivas e nem implantoplastia. A amostra foi randomizada de maneira estratificada para o hábito de fumar e a presente análise, de 3 meses de acompanhamento após o tratamento, se refere à amostra de 22 indivíduos (29 implantes), sendo 12 (17 implantes) no grupo C e 10 (12 implantes) no NC. No início do estudo não foram observadas diferenças significativas entre os grupos para variáveis demográficas e clínicas, exceto nas condições periodontais de índice de placa visível (IPV) (NC 22,3±14,08 / C 40,2±19,9) e sangramento a sondagem (NC 15,9±10,2 / C 31,8±15,9). Após três meses de tratamento, não houve desistências e, considerando o pior sítio do implante, os dois tratamentos reduziram significativamente as medidas de PSi (NC 5,8±0,27 para 4,3±0,55mm / C 5,9±0,29 para 5,0±0,28mm), os dois grupos apresentaram redução de SSi mas apenas no grupo C foi significativa, diminuindo de 100% para 53%. Não houve diferenças entre os níveis de perda de inserção clínica (PIi). Em uma análise multivariada para identificar os preditores de sucesso dos tratamentos, implantes com PSi basal > 6 mm apresentaram piores reduções de PSi, SSi e PIi, o histórico de periodontite dificultou a redução de PSi enquanto indivíduos com 5 ou mais implantes e reabilitados com próteses cimentadas apresentaram piores reduções de SSi. A taxa de sucesso dos tratamentos foi de 33% no grupo NC e 17% para o grupo C sem diferenças estatísticas. Conclui-se que ambos os tratamentos diminuíram sinais inflamatórios embora sem a demonstração de diferenças entre eles, e que preditores de risco ao sucesso do tratamento devem ser investigados. / Peri-implant diseases (PiD) have been considered the major causes of late loss of dental implants, and none of the proposed treatments in the literature demonstrated to be efficient to become the first therapeutic choice. Considering that the correct definition of treatment depends invariably on the understanding of the etiopathogenesis, occurrence and diagnosis of PiD, the aim of the present theses was to approach PiD through a 9oné99ono f its concepts and presenting preliminary clinical data of 3 months from a randomized controlled 9oné9 comparing surgical (ST) and non-surgical (NST) treatments of peri-implantitis. Implants presenting pocket depth (PD) ≥5mm and bleeding on probing (Bosshardt et al.) with radiographic bone loss ≥3 mm were included in the study. NST included mechanical debridement of the implant with Teflon curets and irrigation with saline solution, whereas ST included the debridement with mucoperiostal flap. Ressective surgery and implantoplasty were not applied. The sample was randomized by stratification according to smoking habit, and the present 3-months analysis after treatment referes to 22 individuals (29 implants), 12 (17 implants) in ST and 10 (12 implants) in the NST group. At basliene, no significant differences were observed between groups for demographic and clinical variables, except for periodontal conditions of teeth in regards to visible plaque (NST 22.3±14.08% and ST 40.2±19.9%) and BOP (NST 15.9±10.2% and ST 31.8±15.9%). After 3 months, there were no drop-outs and, considering the worst site of each implant, the two treatments reduced significantly mean PD (NST 5.8±0.27mm to 4.3±0.55mm and ST 5.9±0.29mm to 5.0±0.28mm. Both groups presented reduction in BOP, but only in the ST the reduction was significant, decreasing from 100% to 53%. There were no significant differences in clinical attachment loss after 3 months in the two groups. In a multivariable analysis to identify predictors of treatment success, implants with baseline PD >6mm presented lower reduction in PD over 3 months, as well as BOP and CAL. Previous history of periodontitis lead to higher PD and individuals with more then 5 implants and rehabilitated with bonded prosthesis had higher BOP over time. It can be concluded that both treatments reduced signs of inflammation although without significant differences between them, and baseline PD, number of implants, history of periodontitis and type of prosthetic fixation may be used as predictors of clinical outcomes of peri-implantitis treatment.

Page generated in 0.0866 seconds