1

Determinação de endotoxina bacteriana (pirogênio) em radiofármacos pelo método  de formação de gel. Validação / Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation.

Fukumori, Neuza Taeko Okasaki 28 February 2008 (has links)
Antes do Ensaio do Lisado de Amebócitos do Limulus (LAL), a única forma de se avaliar a pirogenicidade em drogas parenterais e dispositivos médicos era o ensaio de pirogênio em coelhos da Farmacopéia Americana (USP). Especialmente para radiofármacos, o ensaio LAL é a escolha para a determinação de endotoxina bacteriana (pirogênio). O objetivo deste trabalho foi validar o método de formação de gel para alguns radiofármacos sem uma interferência mensurável. O guia do método LAL do Food and Drug Administration (FDA) define interferência como uma condição que causa uma diferença significativa entre os pontos finais de gelificação das séries de controle positivo da água e controle positivo do produto utilizando-se um endotoxina padrão. Os experimentos foram realizados de acordo com o teste de endotoxinas bacterianas da USP na m-iodobenzilguanidina-131I, nos radioisótopos Gálio-67 e Tálio-201, nos reagentes liofilizados DTPA, Fitato, GHA, SAH e Sn Coloidal. A Máxima Diluição Válida (MDV) foi calculada para cada produto com base na sua dose clínica e diluições seriadas abaixo da MDV foram avaliadas em duplicata para a detecção de interferências. A sensibilidade declarada do reagente de LAL foi de 0,125 UE mL-1 (Unidades de Endotoxina por mililitro). Para a validação, uma série de diluições foi feita utilizando-se padrão de endotoxina (PE) nas concentrações de 0,5 a 0,03 UE mL-1 para a confirmação da sensibilidade do reagente de LAL, em quadruplicata. A mesma série de diluições foi feita com o PE e o produto diluído 100 vezes em três lotes consecutivos de cada radiofármaco. Os produtos m-iodobenzilguanidina-131I, Gálio-67, Tálio-201, DTPA, SAH e Sn Coloidal foram compatíveis com o método no fator de diluição 1:100. Fitato e GHA apresentaram interferência no ensaio de formação de gel. Outras técnicas para determinar endotoxinas como o ensaio cromogênico (desenvolvimento de cor) e o turbidimétrico (desenvolvimento de turbidez) foram avaliadas para obter informações qualitativas e quantitativas sobre as concentrações de endotoxinas nas amostras. / Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDAs LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the 131I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the liophylized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL-1 (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL-1, to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products 131I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and qualitative information about the endotoxin concentration in samples.
2

Determinação de endotoxina bacteriana (pirogênio) em radiofármacos pelo método  de formação de gel. Validação / Determination of bacterial endotoxin (pyrogen) in radiopharmaceuticals by the gel clot method. Validation.

Neuza Taeko Okasaki Fukumori 28 February 2008 (has links)
Antes do Ensaio do Lisado de Amebócitos do Limulus (LAL), a única forma de se avaliar a pirogenicidade em drogas parenterais e dispositivos médicos era o ensaio de pirogênio em coelhos da Farmacopéia Americana (USP). Especialmente para radiofármacos, o ensaio LAL é a escolha para a determinação de endotoxina bacteriana (pirogênio). O objetivo deste trabalho foi validar o método de formação de gel para alguns radiofármacos sem uma interferência mensurável. O guia do método LAL do Food and Drug Administration (FDA) define interferência como uma condição que causa uma diferença significativa entre os pontos finais de gelificação das séries de controle positivo da água e controle positivo do produto utilizando-se um endotoxina padrão. Os experimentos foram realizados de acordo com o teste de endotoxinas bacterianas da USP na m-iodobenzilguanidina-131I, nos radioisótopos Gálio-67 e Tálio-201, nos reagentes liofilizados DTPA, Fitato, GHA, SAH e Sn Coloidal. A Máxima Diluição Válida (MDV) foi calculada para cada produto com base na sua dose clínica e diluições seriadas abaixo da MDV foram avaliadas em duplicata para a detecção de interferências. A sensibilidade declarada do reagente de LAL foi de 0,125 UE mL-1 (Unidades de Endotoxina por mililitro). Para a validação, uma série de diluições foi feita utilizando-se padrão de endotoxina (PE) nas concentrações de 0,5 a 0,03 UE mL-1 para a confirmação da sensibilidade do reagente de LAL, em quadruplicata. A mesma série de diluições foi feita com o PE e o produto diluído 100 vezes em três lotes consecutivos de cada radiofármaco. Os produtos m-iodobenzilguanidina-131I, Gálio-67, Tálio-201, DTPA, SAH e Sn Coloidal foram compatíveis com o método no fator de diluição 1:100. Fitato e GHA apresentaram interferência no ensaio de formação de gel. Outras técnicas para determinar endotoxinas como o ensaio cromogênico (desenvolvimento de cor) e o turbidimétrico (desenvolvimento de turbidez) foram avaliadas para obter informações qualitativas e quantitativas sobre as concentrações de endotoxinas nas amostras. / Before the Limulus amebocyte lysate (LAL) test, the only available means of pirogenicity testing for parenteral drugs and medical devices was the United States Pharmacopoeia (USP) rabbit pyrogen test. Especially for radiopharmaceuticals, the LAL assay is the elective way to determine bacterial endotoxin. The aim of this work was to validate the gel clot method for some radiopharmaceuticals without measurable interference. The FDAs LALTest guideline defines interference as a condition that causes a significant difference between the endpoints of a positive water control and positive product control series using a standard endotoxin. Experiments were performed in accordance to the USP bacterial endotoxins test in the 131I- m-iodobenzylguanidine; the radioisotopes Gallium-67 and Thallium-201; the liophylized reagents DTPA, Phytate, GHA, HSA and Colloidal Tin. The Maximum Valid Dilution (MVD) was calculated for each product based upon the clinical dose of the material and a twofold serial dilution below the MVD was performed in duplicate to detect interferences. The labeled sensitivity of the used LAL reagent was 0.125 EU mL-1 (Endotoxin Units per milliliter). For validation, a dilution series was performed, a twofold dilution of control standard endotoxin (CSE) from 0.5 to 0.03 EU mL-1, to confirm the labeled sensitivity of the LAL reagent being tested in sterile and non pyrogenic water, in quadruplicate. The same dilution series was performed with the CSE and the product in the 1:100 dilution factor, in three consecutive batches of each radiopharmaceutical. The products 131I-m-iodobenzylguanidine, Gallium-67, Thallium-201, DTPA, HSA and Colloidal Tin were found compatible with the LAL test at a 1:100 dilution factor. Phytate and GHA showed some interference in the gel clot test. Other techniques to determine endotoxins as the chromogenic (color development) and the turbidimetric test (turbidity development), were also assessed to get valuable quantitative and qualitative information about the endotoxin concentration in samples.
3

A reutilização de coelhos submetidos ao teste de pirogênio com soros hiperimunes sujeitos a vigilância sanitária / The re-use of rabbits subjected to the test pirogen with organic products subject to the health surveillance

Freitas, Carlos Borges Rolim January 2008 (has links)
Made available in DSpace on 2014-07-28T18:10:46Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 88.pdf: 1790108 bytes, checksum: ed390bad661dddf012595ee892a4b51c (MD5) Previous issue date: 2008 / Made available in DSpace on 2014-12-22T16:56:36Z (GMT). No. of bitstreams: 2 88.pdf: 1790108 bytes, checksum: ed390bad661dddf012595ee892a4b51c (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2008 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / Todos produtos injetáveis devem estar livres de pirogênio. Existem dois métodos oficiais para a detecção da contaminação pirogênica: o teste em coelhos e o teste do Lisado do Amebócito de Limulus (LAL), também denominado como ensaio de endotoxina. Entretanto, o LAL tem como limitação detectar somente endotoxinas e sofrer interferências do ajuste do pH, por cátions que neutralizam as cargas negativas das endotoxinas, das altas concentrações de sais, por quelantes que capturam cátions bivalentes e etc. No caso das análises de produtos biológicos (soros hiperimunes, hemoderivados etc), não há reação, possibilitando a resposta de resultados falsos negativos. O Instituto Nacional de Controle de Qualidade em Saúde (INCQS) analisa diversos produtos injetáveis, entre eles, os soros hiperimunes (antivenenos, anti-rábico, anti-tetânico etc) que são distribuídos pelo Programa Nacional de Imunização(PNI/MS) aos postos de saúde. Pela Farmacopéia Brasileira, coelhos que tenham recebido estes produtos no teste de pirogênio não podem ser reutilizados com outros produtos biológicos. Este fato implica na utilização de um grande número de animais para estas análises. / Injectable products must to be free of any kind of pyrogenic contamination. Two methods are the official ones for testing this contamination: the Rabbit Test and the Limulus Amoebocyte Lysate Test (LAL) or so called, Endotoxin Assay. However, LAL is limited only for detecting endotoxin, besides suffering some kind of interferences, it is not possible to test biological products, such as hyperimmune sera, blood derivates etc), since these products produce false-negative results. The National Institute of Quality Control in Health (INCQS) perform analysis of a great variety of injectable products, among them, we find anti-venom, anti-rabies and anti-tetanus sera. The Brazilian Pharmacopoeia states that rabbit which have received previous injection of a biological products is not allowed to be re-used in another assay for the same kind of product. This fact implies on using a great number of animals. Due to the lack of information in the scientific literature about the re-use of rabbits which have received previous injection of hyperimmune sera, this study was elaborated using an experimental design where animals were divided into four groups that received from a single injection of 1ng/mL spiked sera up to a group that received 3 negative sera injections in a 48 hours interval and challenged on day 7 with spiked serum. Results showed that the response to the positive stimulus did not presented significant statistical difference, independently of the amount of negative sera previously injected. So, it was possible to conclude that for Anti-Bothrops, Anti-rabies and Anti-tetanus sera it is possible to reuse rabbits for 4 times within a 7-day period.
4

Avaliação do Teste de Ativação de Monócitos na determinação da contaminação pirogênica com ácido lipoteicóico em produtos injetáveis / Evaluation of Monocyte Activation Test in determining pyrogenic contamination with lipoteichoic acid in injectable products

Lopes, Izabela Gimenes January 2014 (has links)
Submitted by Alexandre Sousa (alexandre.sousa@incqs.fiocruz.br) on 2014-08-01T12:58:03Z No. of bitstreams: 1 Dissertação Izabela.pdf: 1302143 bytes, checksum: ab457123bfc94643d499a3062e8b2cc2 (MD5) / Made available in DSpace on 2014-08-01T12:58:03Z (GMT). No. of bitstreams: 1 Dissertação Izabela.pdf: 1302143 bytes, checksum: ab457123bfc94643d499a3062e8b2cc2 (MD5) Previous issue date: 2014 / Fundação Oswaldo Cruz. Instituto Nacional de Controle de Qualidade em Saúde / O teste de detecção de pirogênio é preconizado nas farmacopeias como teste de segurança imprescindível para a avaliação da qualidade de produtos injetáveis. Os métodos alternativos ao teste de pirogênio em coelhos são o Teste de Lisado de Amebócitos de Limulus (LAL) e o Teste de Ativação de Monócitos (MAT). Esses métodos ainda não podem substituir o teste em coelhos por completo, pois no caso do LAL os resultados podem não ser confiáveis quando a análise é realizada na presença de algumas substâncias interferentes com alto teor de lipídios e proteínas (encontrados nos medicamentos biológicos) e glucanas, além disso, o teste só detecta endotoxinas. Em relação ao MAT, já que o teste é sensível para todos os tipos de pirogênios e tem o mesmo mecanismo biológico responsável pela reação de febre em humanos, o Interagency Coordinating Committee on the Validation of Alternative Methods (ICCVAM) recomendou sua utilização desde que fique demonstrada a equivalência de seus resultados ao teste em coelhos, em conformidade com a regulamentação aplicável. Verifica-se assim, que a literatura carece de dados que envolvam a comparação entre a dose limite que causa febre em coelhos e a correspondência para o MAT relacionado ao ácido lipoteicóico (ALT), sendo assim, esse estudo tem como objetivo principal avaliar a utilização do MAT na detecção da contaminação de ALT de S. aureus em Cloreto de Sódio 0,9 % apirogênico artificialmente contaminado, através do estabelecimento de curva dose-resposta de ALT em coelhos; curva concentração-resposta de ALT para o MAT e avaliação em paralelo dos resultados obtidos utilizando ALT no teste em coelhos, LAL cromogênico e MAT. A resposta de febre foi observada a partir de 75.000 ng de ALT/Kg nos coelhos e no MAT para sangue criopreservado/IL-1β foi estabelecida em 50.000 ng/mL de ALT, ou 5,41 UEE/mL. O teste de LAL apresentou resultado falso-reativo a partir de 10.000 ng/mL de ALT. Os resultados apresentados neste estudo fornecem informações importantes sobre a comparação entre o teste de pirogênio em coelhos, MAT e LAL, contribuindo com dados para a validação do MAT, envolvendo outros pirogênios que não a endotoxina, e também para a aceitação deste teste pelos órgãos regulatórios no Brasil visando uma possível substituição do uso de animais, garantindo, assim, a segurança da saúde da população. / The pyrogenic test is preconized in the Pharmacopeias as a safety test indispensable for the quality of evaluation of injectable products. The alternative methods to the rabbit pyrogen test are the Limulus Amebocite Lysate (LAL) Test and the Monocyte Activation Test (MAT). These methods cannot replace the rabbit test completely yet, for in the case of LAL the results may not be reliable when the analysis is carried out in the presence of some interfering substances with high content of lipids and proteins (found in biological medicines) and glucans, moreover, the test only detects endotoxins. Concerning the MAT, since the test is sensitive to all types of pyrogens and has the same biological mechanism responsible for the fever reaction in humans, the Interagency Coordinating Committee on the Validation of Alternative Methods (Comitê de Coordenação Interagências sobre Validação de Métodos Alternativos - ICCVAM) have recommended its utilization provided that the equivalence of its results from the rabbit test, in conformity with the applicable regulation. It can be verified, then, that the literature lacks the data which involves the comparison between the limit dose that causes fever in rabbits and the consequence for the MAT related to the lipoteichoic acid (LTA), that being so, the aim of this study is mainly the utilization of MAT in the detection of the contamination of LTA of S. aureus in apyrogenic 0.9 % Sodium Chloride artificially contaminated, through the establishment of the dose-response curve of LTA in rabbits; concentration-response curve of LTA for the MAT and parallel evaluation of the results obtained by utilizing LTA in the test in rabbits, chromogenic LAL and MAT. The fever response was observed from 75.000 ng of LTA/Kg in rabbits and in MAT and for cryopreserved blood/IL-1β was established in 50.000 ng/mL of LTA, or 5,41 UEE/mL. The LAL test presented a false-positive result from 10.000 ng/mL of ALT. The results presented in this study provide important information on the comparison between the rabbit pyrogen test, MAT and LAL, contributing with data to the evaluation of MAT, involving pyrogens other than endotoxin, and also to the acceptance of this test by the regulatory organs in Brazil aiming at a possible animal substitution, and guaranteeing, then, the health security of the population.

Page generated in 0.045 seconds