• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 34
  • 22
  • 9
  • 6
  • 2
  • 2
  • Tagged with
  • 82
  • 21
  • 20
  • 18
  • 18
  • 16
  • 16
  • 15
  • 13
  • 13
  • 12
  • 11
  • 10
  • 10
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Installation et mise en oeuvre d'un détecteur de rayons X à pixels hybrides sur un diffractomètre de laboratoire : applications aux études de densité électronique et aux expériences de cristallographie résolues en temps / Installation and commissioning of a hybrid pixels X-ray detector on a laboratory diffractometer : Applications to electron density studies and time-resolved crystallography

Wenger, Emmanuel 29 May 2015 (has links)
Par rapport aux détecteurs de rayons X couramment utilisés pour la cristallographie, les détecteurs à pixels hybrides apportent des avantages majeurs qui proviennent principalement de l’utilisation d'une chaîne de comptage propre à chaque pixel permettant de compter les photons individuellement et très rapidement. Les principales innovations de ces détecteurs sont les suivantes : (1) Suppression quasi totale du bruit ; (2) Obturateur électronique ultra rapide (de l'ordre de 100 ns) ; (3) Vitesse d'acquisition de 500 images par seconde. Ces avantages déjà mis à profit depuis une petite dizaine d’années sur les lignes synchrotron, sont également très prometteurs pour les diffractomètres de laboratoire. L’objet de la thèse a été de développer un diffractomètre expérimental de laboratoire équipé d’un détecteur à pixels hybrides, XPAD, et de réaliser les premières mesures de diffraction sur monocristal. Ces mesures ont permis de déterminer les corrections et calibrations du détecteur nécessaires pour les mesures sur monocristaux. Conjointement, les méthodes et techniques de traitement des images pour intégrer les intensités de diffraction ont été étudiées. L’intérêt du très faible bruit du détecteur pour l’étude de modèles de densité électronique a été démontré ; le prototype avec le détecteur XPAD a donné de meilleurs résultats que les diffractomètres usuels. Une deuxième application a consisté à utiliser les qualités de vitesse du détecteur pixel pour la mise en œuvre de mesures résolues en temps à l’échelle de la milliseconde. Des mesures sous champs électrique commuté ont permis de montrer le potentiel de ce type de détecteur dans ce domaine de recherche / Compared to X-ray detectors commonly used for crystallography, hybrid pixels detectors provide major advantages primarily due to the use of a counting system proper to each pixel allowing for very fast and individual photon counting. The main innovations of these detectors are: (1) Almost total suppression of noise ; (2) Ultra-fast electronic shutter (about 100 ns) ; (3) Acquisition rate of 500 images per second. These advantages have already been exploited over the past ten years on synchrotron beam lines and are also very promising for laboratory diffractometers. The thesis work was to realize a prototype laboratory diffractometer equipped with such a detector, XPAD, and to achieve single crystal X-ray diffraction measurements. The necessary corrections and calibrations of the detector required for diffraction measurements on single crystals were determined. The methods and image processing techniques to integrate the diffraction intensities were studied. Benefits of the very low noise of the detector for electron density models study were demonstrated; the prototype diffractometer equipped with an XPAD detector gave better results than conventional diffractometers. A second type of application was to use the pixel detector for the implementation of time-resolved diffraction measurements at millisecond timescale. Measurements under switched electric fields have shown the potential of this type of detector in this area of research
32

ROBUST BACKGROUND SUBTRACTION FOR MOVING CAMERAS AND THEIR APPLICATIONS IN EGO-VISION SYSTEMS

Sajid, Hasan 01 January 2016 (has links)
Background subtraction is the algorithmic process that segments out the region of interest often known as foreground from the background. Extensive literature and numerous algorithms exist in this domain, but most research have focused on videos captured by static cameras. The proliferation of portable platforms equipped with cameras has resulted in a large amount of video data being generated from moving cameras. This motivates the need for foundational algorithms for foreground/background segmentation in videos from moving cameras. In this dissertation, I propose three new types of background subtraction algorithms for moving cameras based on appearance, motion, and a combination of them. Comprehensive evaluation of the proposed approaches on publicly available test sequences show superiority of our system over state-of-the-art algorithms. The first method is an appearance-based global modeling of foreground and background. Features are extracted by sliding a fixed size window over the entire image without any spatial constraint to accommodate arbitrary camera movements. Supervised learning method is then used to build foreground and background models. This method is suitable for limited scene scenarios such as Pan-Tilt-Zoom surveillance cameras. The second method relies on motion. It comprises of an innovative background motion approximation mechanism followed by spatial regulation through a Mega-Pixel denoising process. This work does not need to maintain any costly appearance models and is therefore appropriate for resource constraint ego-vision systems. The proposed segmentation combined with skin cues is validated by a novel application on authenticating hand-gestured signature captured by wearable cameras. The third method combines both motion and appearance. Foreground probabilities are jointly estimated by motion and appearance. After the mega-pixel denoising process, the probability estimates and gradient image are combined by Graph-Cut to produce the segmentation mask. This method is universal as it can handle all types of moving cameras.
33

LHC luminosity measurement with the ATLAS-MPX detectors

Asbah, Nedaa 12 1900 (has links)
En opération depuis 2008, l’expérience ATLAS est la plus grande de toutes les expériences au LHC. Les détecteurs ATLAS- MPX (MPX) installés dans ATLAS sont basés sur le détecteur au silicium à pixels Medipix2 qui a été développé par la collaboration Medipix au CERN pour faire de l’imagerie en temps réel. Les détecteurs MPX peuvent être utilisés pour mesurer la luminosité. Ils ont été installés à seize différents endroits dans les zones expérimentale et technique d’ATLAS en 2008. Le réseau MPX a recueilli avec succès des données indépendamment de la chaîne d’enregistrement des données ATLAS de 2008 à 2013. Chaque détecteur MPX fournit des mesures de la luminosité intégrée du LHC. Ce mémoire décrit la méthode d’étalonnage de la luminosité absolue mesurée avec les détectors MPX et la performance des détecteurs MPX pour les données de luminosité en 2012. Une constante d’étalonnage de la luminosité a été déterminée. L’étalonnage est basé sur technique de van der Meer (vdM). Cette technique permet la mesure de la taille des deux faisceaux en recouvrement dans le plan vertical et horizontal au point d’interaction d’ATLAS (IP1). La détermination de la luminosité absolue nécessite la connaissance précise de l’intensité des faisceaux et du nombre de trains de particules. Les trois balayages d’étalonnage ont été analysés et les résultats obtenus par les détecteurs MPX ont été comparés aux autres détecteurs d’ATLAS dédiés spécifiquement à la mesure de la luminosité. La luminosité obtenue à partir des balayages vdM a été comparée à la luminosité des collisions proton- proton avant et après les balayages vdM. Le réseau des détecteurs MPX donne des informations fiables pour la détermination de la luminosité de l’expérience ATLAS sur un large intervalle (luminosité de 5 × 10^29 cm−2 s−1 jusqu’à 7 × 10^33 cm−2 s−1 . / In operation since 2008, the ATLAS experiment is the largest of all the experiments at the LHC. The ATLAS-MPX (MPX) detectors installed in ATLAS are based on the Medipix2 silicon pixelated detector which has been developed by the Medipix Collaboration at CERN to perform real-time imaging. They can be used for luminosity measurements. They were installed at sixteen different positions in the ATLAS cavern at the LHC in 2008. The MPX network successfully collected data independently of the ATLAS data recording chain from 2008 to 2013. Each MPX detector provides measurements of the integrated LHC luminosity. This thesis describes the technique for calibrating the luminosity data and performance of MPX detectors for measuring the luminosity in 2012. The calibration was performed via the van der Meer (vdM) scans technique which allows the measurement of the convolved beam sizes in the vertical and the horizontal planes at the ATLAS interaction point (IP1). The determination of the absolute luminosity requires a precise knowledge of the beam intensities and the number of beam bunches. A luminosity calibration constant was determined. The three calibration scans were analyzed and the results were cross-checked among the MPX detectors and other ATLAS sub-detectors specifically dedicated to luminosity measurement. The luminosity determined from the calibration scans was compared to the luminosity of regular runs before and after the vdM scans. The MPX network gives reliable information for the overall ATLAS luminosity determination over a wide dynamic range (luminosity from 5 × 10^29 cm−2 s−1 up to 7 × 10^33 cm−2 s−1).
34

Design of back-illuminated voltage-domain global shutter pixels with dual in-pixel storage

Stark, Laurence January 2017 (has links)
Global shutter pixels are indispensable for applications wherein the minimisation of motion artefacts is of critical importance. However, these pixels are more complex than the common rolling shutter type pixels and require some form of per-pixel storage. They are almost invariably reliant upon metal light shielding in order to protect their in-pixel memory nodes and this prevents them from taking advantage of some of the latest developments in CMOS image sensor technology. Backside-illumination is the most prominent example of such a technology. The greater sensitivity afforded by the reduced optical stack height is indispensable for many applications, particularly in the mobile market where form factor and power consumption are constrained. The design challenge is to exploit these advantages offered by backside-illumination without making use of metal shielding of the per-pixel memory. The research in this thesis covers the design, implementation and characterisation of a back-illuminated voltage-domain global shutter pixel. The pixel architecture is a novel 10 transistor-per-pixel architecture with dual independent in-pixel storage nodes. Beginning with the pixel architecture, the design is developed through TCAD-driven photodiode and pixel layout co-optimisation. The behaviour of pixels with differential parasitic light sensitivity (PLS) behaviour is analysed in greater detail than previously reported and a prediction model is developed based upon this. The 10T pixel is characterised and found to have excellent PLS of -73:5 dB native and -82:5 dB differential PLS at 940 nm. The dual in-pixel storage enables the pixel to operate either in a low noise correlated double sampling mode with differential PLS, or in an exposure-bracketed high dynamic range imaging (HDR) mode. This HDR mode is successfully demonstrated and yields substantial enhancement of the pixel dynamic range.
35

Remote sensing of the spatio-temporal distribution of invasive water hyacinth (Eichhornia crassipes) in the Greater Letaba River System in Tzaneen, South Africa

Thamaga, Kgabo Humphrey January 2018 (has links)
Thesis (MSc. (Geography)) --University of Limpopo, 2018 / Water hyacinth (Eichhornia crassipes) is recognised as the most notorious invasive species the world-over. Although its threats and effects are fully documented, its distribution is not yet understood, especially in complex environments, such as river systems. This has been associated with the lack of accurate (high spatial resolution) and robust techniques, together with the reliable data sources necessary for its quantification and monitoring. The advent of new generation sensors i.e. Landsat 8 Operational Land Imager (OLI) and Sentinel-2 MultiSpectral Instrument (MSI) data, with unique sensor design and improved sensing characteristics is therefore perceived to provide new opportunities for mapping the distribution of invasive water hyacinth in small waterbodies. This study aimed at mapping and understanding the spatio-temporal distribution of invasive water hyacinth in the Greater Letaba river system in Tzaneen, Limpopo Province of South Africa using Landsat 8 OLI and Sentinel-2 MSI data. Specifically, the study sought to identify multispectral remote sensing variables that can optimally detect and map invasive water hyacinth. Landsat 8 OLI and Sentinel-2 MSI were tested based on the spectral bands, vegetation indices, as well as the combined spectral bands plus vegetation indices, using discriminant analysis algorithm. From the findings, Sentinel-2 MSI outperformed Landsat 8 OLI in mapping water hyacinth, with an overall classification (OA) accuracy of 77.56% and 68.44%, respectively. This observation was further confirmed by a t-test statistical analysis which showed that there were significant differences (t=6.313, p<0.04) between the performance of the two sensors. Secondly, the study sought to map the spatial distribution of invasive water hyacinth in the river system over time (Seasonal). Multi-date 10 m Sentinel-2 MSI images were used to detect and monitor the seasonal distribution and variations of water hyacinth in the Greater Letaba River system. The study demonstrated that, about 63.82% of the river system was infested with water hyacinth during the wet season and 28.34% during the dry season. Sentinel-2 MSI managed to depict species spatio-temporal distribution with an OA of 80.79% during wet season and 79.04% in dry season, using integrated spectral bands and vegetation indices. New generation sensors provide new opportunities and potential for seasonal or long-term monitoring of aquatic invasive species like water hyacinth- a previously challenging task with broadband multispectral sensors. / Risk and Vulnerability Science Centre (RSVC)
36

Étiquetage des quarks b par un détecteur de vertex à pixels dans l'expérience ATLAS auprès du LHC

Vacavant, Laurent 13 June 1997 (has links) (PDF)
Dans ce travail, les potentialités du détecteur ATLAS pour l'identification des jets issus de quark beau sont étudiées. L'étiquetage topologique, basé sur le paramètre d'impact des traces chargées, est utilisé. Une bonne identification de ces jets sera très précieuse au LHC, en particulier durant les premières années de fonctionnement pour mettre en évidence le cas échéant un boson de Higgs d'une masse comprise entre 80 GeV/c2 et 120 GeV/c2. Pour évaluer les performances dans ce domaine, un algorithme de recherche et reconstruction des traces chargées exploitant la simulation détaillée du détecteur interne d'ATLAS a été réalisé. La recherche est initiée dans les détecteurs à pixels. L'efficacité et la qualité de reconstruction assurent une bonne discrimination entre les jets b et les autres jets. Après simulation complète et reconstruction d'événements H->bbbar, H->gg, H->uubar, H->ssbar et H->ccbar (mH = 100 GeV/c2), les réjections moyennes des jets non-b pour une efficacité d'étiqueter les jets b de 50% sont: Rg = 39+-5 Ru = 60+-9 Rs = 38+-5 Rc = 9+-1 Les résultats de l'analyse des données prises lors de tests en faisceau des premiers prototypes de matrices de détecteurs à pixels en technologie résistante aux radiations justifient les potentialités de ce type de détecteur pour la recherche de traces et la mesure précise de leur paramètre d'impact.
37

Recherche d'un boson de Higgs leger produit en association avec une paire de quarks top dans l'experience ATLAS

Leveque, Jessica 30 June 2003 (has links) (PDF)
L'un des principaux objectifs de l'experience ATLAS est la recherche de la derniere particule manquante du modele standard, le boson de Higgs, et l'etude de ses proprietes. Cette experience sera placee aupres du futur collisionneur de protons LHC, dont le demarrage est prevu pour l'annee 2007 au CERN. Les travaux presentes dans cette these sont dedies a la recherche d'un boson de Higgs de masse inferieure a 200 GeV/c2, dans le canal de production associee pp->ttH. L'identification des jets contenant des hadrons beaux est fondamentale pour l'etude du boson de Higgs et du quark top. Les performances d'etiquetage des jets b sont etudiees en details dans le canal ttH, H->bb, et pour des conditions de fonctionnement tres proches de celles attendues au demarrage des prises de donnees, (detecteur a pixels incomplet, bruit d'empilement et inefficacites de detection). Pour une efficacite d'identifcation de jets b de 60%, les taux de rejet attendus sont de 80% pour les jets legers et 7% pour les jets c. Si la decouverte du boson de Higgs dans ATLAS semble relativement aisee, la mesure de ses parametres, et en particulier la determination des couplages aux differents fermions, est beaucoup plus delicate. Une etude de faisabilite est proposee pour un nouveau canal, ttH, H->WW(*). Ce canal est le seul qui permet une determination directe du couplage de Yukawa du quark top dans l'intervalle de masse 130-200 GeV/c2. Pour un boson de Higgs de 160 GeV/c2, la precision statistique attendue apres trois annees de prise de donnees a haute luminosite est de 7 %.
38

Développement d'une caméra à rayons X ultra-rapide utilisant des détecteurs à pixels hybrides.

Dawiec, Arkadiusz 04 May 2011 (has links) (PDF)
L'objectif du projet, dont le travail présenté dans cette thèse est une partie, était de développer une caméra à rayons X ultra-rapide utilisant des pixels hybrides pour l'imagerie biomédicale et la science des matériaux. La technologie à pixels hybrides permet de répondre aux besoins des ces deux champs de recherche, en particulier en apportant la possibilité de sélectionner l'énergie des rayons X détectés et de les imager à faible dose. Dans cette thèse, nous présentons une caméra ultra-rapide basée sur l'utilisation de circuits intégrés XPAD3-S développés pour le comptage de rayons X. En collaboration avec l'ESRF et SOLEIL, le CPPM a construit trois caméras XPAD3. Deux d'entre elles sont utilisée sur les lignes de faisceau des synchrotrons SOLEIL et ESRF, et le troisième est installé dans le dispositif d'irradiation PIXSCAN II du CPPM. La caméra XPAD3 est un détecteur de rayons X de grande surface composé de huit modules de détection comprenant chacun sept circuits XPAD3-S équipés d'un système d'acquisition de données ultrarapide. Le système de lecture de la caméra est basé sur l'interface PCI Express et sur l'utilisation de circuits programmables FPGA. La caméra permet d'obtenir jusqu'à 240 images/s, le nombre maximum d'images étant limité par la taille de la mémoire RAM du PC d'acquisition. Les performances de ce dispositif ont été caractérisées grâce à plusieurs expériences à haut d'ebit de lecture réalisées dans le système d'irradiation PIXSCAN II. Celles-ci sont décrites dans le dernier chapitre de cette thèse.
39

Habilitation à Diriger des Recherches

Calvet, D. 21 March 2011 (has links) (PDF)
Ce document résume mes activités entre 1995 et 2010. Dans un premier temps, le développement d'un détecteur à pixels de silicium pour l'amélioration du Forward Proton Spectrometer de l'expérience H1 à DESY est présenté. Ensuite, les développements des circuits de lecture du détecteur à pixels de l'expérience ATLAS au CERN sont détaillés, en particulier le développement de bancs de test de ces circuits ainsi que la simulaton de leur comportement dans un environnement réaliste. Puis, l'infrastructure de la digitization des détecteurs à silicium (Pixels et SCT) est présentée. Une deuxième partie décrit la production de l'électronique frontale de lecture du calorimètre hadronique à tuiles scintillantes d'ATLAS (TileCal), en particulier le développement du système de test MobiDICK. Les logiciels de contrôle du système de calibration du TileCal par laser sont aussi détaillés. Pour finir, mes activités d'enseignement, d'encadrement et de diffusion des connaissances (en particulier le Cosmophone) sont mentionnées.
40

Mesure de formes et de champs de déplacements tridimensionnels par stéréo-corrélation d'images

Garcia, Dorian 21 December 2001 (has links) (PDF)
De nombreux domaines concernant le comportement mécanique des matériaux posent le problème de la mesure des déplacements ou des déformations. Pour ce type de mesure, les méthodes optiques se sont largement imposées en raison de leur caractère non intrusif, de leur grande résolution spatiale, de leur sensibilité élevée, de l'importance du champ examiné à tout instant et des progrès de l'informatique qui permet le traitement automatique d'un grand volume d'information.<br /><br />Dans ce contexte, nous avons développé un système de mesure de formes 3D ou de champs de déplacements 3D par stéréovision (en particulier par stéréo-corrélation).<br /><br />Cette technique permet : (1) la mesure de la forme 3D d'un objet à partir d'une simple paire d'images stéréoscopiques de l'objet, (2) la mesure de champs de déplacements 3D à partir d'au moins 2 paires d'images correspondant à différents instants de déformation de l'objet (en général analyse d'une séquence de paires d'images acquises en cours de déformation).<br /><br />Les points développés dans la thèse sont : le calibrage fort d'une caméra ou d'un capteur de vision stéréoscopique, la reconstruction 3D par stéréovision (en particulier par stéréo-corrélation), la mesure de champs de déplacements 3D à partir du couplage de la stéréo-corrélation et du suivi de pixels dans une séquence d'images par corrélation. Compte tenu de la finalité métrologique de ces travaux, nous accordons une attention toute particulière à la précision des méthodes mises en oeuvre (qualité du calibrage, qualité de la mise en correspondance des images, corrélation subpixel,...).<br /><br />Ces travaux ont été appliqués à l'emboutissage de tôles minces (mesure de formes 3D d'emboutis et mesure de champs de déformations à la surface d'emboutis 3D), à la mise en forme de polymères (mesure de champs de déplacements 3D sur des membranes en élastomère soufflées), et à l'étude du comportement mécanique de bétons réfractaires renforcés de fibres métalliques (mesure de champs de déplacements 3D lors d'essais de traction).

Page generated in 0.1346 seconds