Spelling suggestions: "subject:"potenciais visuais provocados""
1 |
Análise de técnicas de separação cega de fontes para remoção de artefatos em interfaces cérebro-máquinaAlmeida, Cristiano Camilo dos Santos de January 2013 (has links)
Orientador: Ricardo Suyama / Dissertação (mestrado) - Universidade Federal do ABC. Programa de Pós-Graduação em Engenharia da Informação, 2013
|
2 |
Avaliação da acuidade visual em crianças com hidrocefalia : um estudo eletrofisiológico por potencial visual evocado de varredura / Visual acuity evaluation in children with hydrocephalus : an electrophysiological study with sweep visual evoked potentialPereira, Silvana Alves 22 April 2008 (has links)
O objetivo do estudo foi medir a acuidade visual (AV) em crianças com diagnóstico de hidrocefalia, apresentando ou não a válvula de derivação ventricular (DVP). Participaram da pesquisa um total de 55 crianças (34 F e 21M) com diagnóstico de hidrocefalia (45 com DVP e 10 sem DVP), com idade entre zero a 291 semanas (média 74 semanas). A AV foi medida pela técnica do Potencial Visual Evocado de Varredura e os resultados foram comparados a valores de referência (Norcia, 1985b). Os diagnósticos etiológicos que levaram à hidrocefalia foram: hemorragia intracraniana (25 crianças), mielomeningocele (20 crianças) e hidrocefalia congênita (10 crianças). O diagnóstico de hidrocefalia foi estabelecido em média no 16° dia de vida. Verificamos que, 31 crianças tiveram o procedimento realizado com menos de 15 dias do diagnóstico de hidrocefalia enquanto que em 14 a válvula foi instalada após 15 dias. Das 55 crianças avaliadas no 1° exame, 18 fizeram o 2° exame, 13 fizeram o 3° exame, 10 completaram quatro exames e apenas cinco completaram as cinco avaliações. Os resultados mostram que dentre as 101 avaliações de AV realizadas em todas as crianças, 95 exames (94%) se mostraram alterados e seis normais. Não há diferença estatística entre a AV das crianças sem derivação em comparação com aquelas crianças cuja DVP foi realizada com tempo de derivação maior que 15 dias (p = 0.699). Houve, todavia, uma diferença estatística na AV, quando comparamos as crianças, cujas derivações foram realizadas em até 15 dias do diagnóstico da hidrocefalia, com aquelas cuja derivação foi realizada após 15 dias (p = 0.038) ou com aquelas que não foram derivadas (p = 0.031). Crianças que não tiveram complicações na DVP tiveram um melhor resultado de AV quando comparado com o grupo com complicação (p = 0.0001). No grupo de crianças com complicação, novamente aquelas que foram derivadas com tempo inferior a 15 dias do diagnóstico da hidrocefalia apresentou melhores resultados de AV quando comparado com aquelas crianças com complicação cuja derivação foi realizada com mais de 15 dias (p = 0.029). Nós concluímos que é possível a medida da acuidade visual de resolução pelos PVEs de varredura em crianças com diagnóstico de hidrocefalia e os valores geralmente são piores comparando aos valores normativos. O tempo da derivação e o número de complicações decorrentes da DVP parecem interferir nesta diferença. Em nosso conhecimento, este foi o primeiro trabalho a avaliar progressivamente, a acuidade visual de crianças, nos primeiros anos de vida, com hidrocefalia, com ou sem DVP e correlacionar o resultado com o tempo de derivações e número de complicações. Apesar da grande evolução tecnológica alcançada pela oftalmologia, ainda não somos capazes de prevenir as alterações visuais detectáveis pelo simples exame de AV nas crianças com hidrocefalia. O tempo para a inserção da válvula de derivação e o tratamento para as complicações ainda são medidas retardadas devido à prematuridade, instabilidade hemodinâmica e a não autorização do familiar. Estes motivos podem comprometer o desenvolvimento visual destas crianças. / The objective was to measure the visual acuity (VA) of children with the diagnosis of hydrocephalus with or without peritoneal-ventricular shunt (PVS). A total of 55 children with the diagnosis of hydrocephalus (45 with PVS and 10 without PVS) were included in the study (34F and 21M), with an age range of 0 to 291 weeks (mean=74 weeks). The VA was measured by the sweep visual evoked potential technique and the results were compared with reference values proposed by Norcia (1985b). Etiological diagnosis of the hydrocephalus was as follows: intracranial hemorrhage (25 children), meningomyelocele (20 children) and congenital hydrocephalus (10 children). The diagnosis of hydrocephalus was made in an average time of 16 days of life. After the diagnosis, the insertion of the PVS, when made, was accomplished in average on the 16th day. Of those with a PVS, in 31 the ventricular valve was inserted before 15 days after the diagnosis whereas in 14 in shunt was inserted after 15 days. Of the 55 children evaluated in the first exam, 18 were evaluated in a second exam, 13 did the third exam, 10 completed 4 exams and only 5 completed the 5 evaluations. The results of the 101 sweep visual evoked potential performed in all children, 95 exams (94%) were abnormal and only 6 were normal. There was no statistical difference in the VA of children without a ventricular shunt in comparison with those in which the shunt was inserted after 15 days of the diagnosis of hydrocephalus (p=0.699). There was, however, a statistical difference in the VA between children with a ventricular shunt inserted before 15 days of the diagnosis and children with a ventricular shunt after 15 days (p=0.038) or those without a shunt (p=0.031). Children with no complications of the ventricular shunt had a better VA as compared to those with shunt complications (p= 0.0001). In the group of children with complications, again those who had a shunt inserted before 15 days bad better VA results in comparison to those in whom the shunt was inserted after 15days (p=0.029). We concluded that measuring visual acuity by sweep visual evoked potential is feasible in children with the diagnosis of hydrocephalus and that results are usually worse comparing with reference values. The timing for insertion of a ventricular shunt and the occurrence of complications of this procedure are factors that may influence the VA. To our knowledge, this is the first study that progressively evaluated the VA in children, of early age, with hydrocephalus, with or without a ventricular shunt and correlated the VA with the timing and complications of the ventricular shunt. Despite the great technological advance in ophthalmology, we are still unable to prevent visual impairments, detectable by simple visual acuity tests, in children with hydrocephalus. The timing of the insertion of the ventricular shunt and the adequate treatment of the potential complications may be delayed due to prematurity, hemodynamic instability and family refusal. This delay may compromise the visual development of these children.
|
3 |
Repercussões visuais da exposição ocupacional a uma mistura de solventes orgânicos: visão cromática e acromática em frentistas brasileiros / Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workersCosta, Thiago Leiros 13 December 2010 (has links)
Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicos / Purpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffuse
|
4 |
Repercussões visuais da exposição ocupacional a uma mistura de solventes orgânicos: visão cromática e acromática em frentistas brasileiros / Visual repercussions of occupational exposure to a mixture of solvents: Chromatic and achromatic vision in brazilian gas station workersThiago Leiros Costa 13 December 2010 (has links)
Objetivo: Avaliar repercussões da exposição ocupacional a uma mistura de solventes orgânicos sobre o desempenho visual de um grupo de frentistas. Método: Foram aplicados testes de ordenamento e discriminação de matizes, campo visual e sensibilidade ao contraste espacial de luminância em 25 frentistas (20 homens, M=36,4 anos, DP=8,9) e 25 controles sem histórico de exposição crônica a solventes (10 homens, M=33,8 anos, DP=8,8). As concentrações metabólitos urinários de tolueno (M=0,3 g/g de creatinina; DP=0,16) e xileno (M=0,1 g/g de creatinina; DP=0,02) e o tempo de trabalho (M=9,6 anos; DP=6,2) foram utilizados como indicativos da exposição dos frentistas. Os participantes foram submetidos a exame oftalmológico, e quando necessário, corrigir a acuidade visual para 20/20. Todas as medidas foram realizadas monocularmente com um olho escolhido ao acaso, com exceção do Potencial Visual Evocado Multifocal (PVEmf) e da campimetria. Para avaliar a visão de cores, utilizamos o Lanthony D15-d e Cambridge Colour Test 2.0. Na campimetria estática automatizada foi utilizado o protocolo branco-branco 24-2 do aparelho Humphrey Field Analyzer II-750i. A atividade elétrica visual cortical foi avaliada com o sistema de PVEmf Veris Science 5.2.4, utilizando um estímulo de 60 setores. A sensibilidade ao contraste espacial de luminância foi avaliada no teste Metropsis, para grades senoidais em 7 frequências espaciais de 0,2 a 20,0 cpg. Resultados: Os escores do grupo de frentistas e do grupo controle foram comparados pelo teste Mann-Whitney U. No teste de discriminação de cores (CCT), houve diferença estatística significativa entre controles e frentistas para a área total da elipse (p<0,01), elipticidade (p<0,05) e limiares nos eixos protan, deutan e tritan (p<0,05). No D15d houve diferença significativa entre os 8 dois grupos (p<0,01). Os dados da campimetria apresentaram diferenças significativas entre os dois grupos para as excentricidades de 90, 150 e 210, além dos valores de MD e PSD (p<0,05). Dos três frentistas avaliados com o PVEmf, todos apresentaram uma diminuição significativa (p<0,05) da amplitude do sinal (em relação a dados normativos) em um mínimo de 30 setores do campo visual, resultado que não foi observado no grupo controle. Nos testes de visão de cores, foi encontrada uma correlação (Spearman) positiva e significativa entre o tempo de trabalho e os índices do Lanthony D15d (p=0,52; p<0,05) e os limiares no eixo deutan (p=0,59; p<0,05). Na campimetria, houve correlações negativas significativas com o tempo de trabalho para a área da Fóvea (p=-051; p<0,05), e para os anéis de 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). Não foi encontrada correlação significativa entre a sensibilidade ao contraste e o tempo de trabalho. Conclusões: Os resultados mostram alterações amplas e difusas no processamento visual em decorrência da exposição crônica a solventes orgânicos / Purpose: To evaluate the outcome of chronic occupational exposure to a mixture of solvents on the visual system of a group of gas station workers. Methods: 25 gas station workers (20 male; M=36,4 years old, SD=8,9) and 25 controls (10 male; M=33,8 years old, DP=8,8) with no history of chronic exposure to solvents were tested for hue discrimination and arrangement, spatial contrast sensitivity, visual field and multifocal VEPs. Urinary concentrations of toluene (M=0,3g/g of creatinine; Sd=0,16) and xylene metabolites (M=0,1 g/g creatinine; SD=0), along with the time of work (M=9,6 years; SD=6,2) were used as indicators of the exposure. The participants were submitted to an ophthalmologic examination and corrected the visual acuity to 20/20 whenever needed. All measurements were monocular (eye randomly chosen) and only one eye was tested, except for Multifocal Visual Evoked Potential (mfVEP) and the automated perimetry. Color was evaluated with the Lanthony D15d and Cambridge Colour Test 2.0. Automatic static perimetry used the white-on-white 24-2 protocol of the Humphrey Field Analyzer II-750i. Visual field was also evaluated with the mfVEP system Veris Science 5.2.4. Contrast sensitivity was measured with Metropsis software, using sine wave gratings of 0,2; 0,5; 1,0; 2,0; 5,0; 10,0 and 20,0 cpd. Results: The results for the two groups were compared using the Mann-Whitney U test. In the color discrimination test, the groups were significantly different for the thresholds in the three confusion axis tested (p<0,05), area of the ellipse (p<0,01) and ellipticity (p<0,05). In the color arrangement test, the two groups were significantly different (p<0,01). The automated perimetry results were also significantly different between groups for the 90, 150 e 210 eccentricity rings (p<0,05) and the MD and PSD values (p<0,05). Only three of the workers were tested with the mfVEP so far. All three had at least 30 sectors in the visual field 10 with significant loss of amplitude in the response (p<0,05, when compared to normative data). This result was not observed in the control group. The Spearman correlation coefficient was used to look for significant correlations between time of work and visual performance. For color vision, we found significant positive correlation between time of work and indexes of the Lanthony D15d (p=0,52; p<0,05) and deutan axis thresholds (p=0,59; p<0,05) for the CCT test. The analysis of sensitivity in eccentricity rings of perimetry data showed significant negative correlation with the time of work for the Fovea (p=-051; p<0,05) and rings of 30 (p=-0,46; p<0,05), 90 (p=-0,46; p<0,05) e 150 (p=-0,46; p<0,05). The contrast sensitivity data was not significantly correlated with time of work. Conclusions: The results presented here suggest that chronic occupational exposure to organic solvents leads to changes in the visual system function even when the exposure is within occupational safety limits. The results also suggest that the visual changes are extensive and diffuse
|
5 |
Avaliação da acuidade visual em crianças com hidrocefalia : um estudo eletrofisiológico por potencial visual evocado de varredura / Visual acuity evaluation in children with hydrocephalus : an electrophysiological study with sweep visual evoked potentialSilvana Alves Pereira 22 April 2008 (has links)
O objetivo do estudo foi medir a acuidade visual (AV) em crianças com diagnóstico de hidrocefalia, apresentando ou não a válvula de derivação ventricular (DVP). Participaram da pesquisa um total de 55 crianças (34 F e 21M) com diagnóstico de hidrocefalia (45 com DVP e 10 sem DVP), com idade entre zero a 291 semanas (média 74 semanas). A AV foi medida pela técnica do Potencial Visual Evocado de Varredura e os resultados foram comparados a valores de referência (Norcia, 1985b). Os diagnósticos etiológicos que levaram à hidrocefalia foram: hemorragia intracraniana (25 crianças), mielomeningocele (20 crianças) e hidrocefalia congênita (10 crianças). O diagnóstico de hidrocefalia foi estabelecido em média no 16° dia de vida. Verificamos que, 31 crianças tiveram o procedimento realizado com menos de 15 dias do diagnóstico de hidrocefalia enquanto que em 14 a válvula foi instalada após 15 dias. Das 55 crianças avaliadas no 1° exame, 18 fizeram o 2° exame, 13 fizeram o 3° exame, 10 completaram quatro exames e apenas cinco completaram as cinco avaliações. Os resultados mostram que dentre as 101 avaliações de AV realizadas em todas as crianças, 95 exames (94%) se mostraram alterados e seis normais. Não há diferença estatística entre a AV das crianças sem derivação em comparação com aquelas crianças cuja DVP foi realizada com tempo de derivação maior que 15 dias (p = 0.699). Houve, todavia, uma diferença estatística na AV, quando comparamos as crianças, cujas derivações foram realizadas em até 15 dias do diagnóstico da hidrocefalia, com aquelas cuja derivação foi realizada após 15 dias (p = 0.038) ou com aquelas que não foram derivadas (p = 0.031). Crianças que não tiveram complicações na DVP tiveram um melhor resultado de AV quando comparado com o grupo com complicação (p = 0.0001). No grupo de crianças com complicação, novamente aquelas que foram derivadas com tempo inferior a 15 dias do diagnóstico da hidrocefalia apresentou melhores resultados de AV quando comparado com aquelas crianças com complicação cuja derivação foi realizada com mais de 15 dias (p = 0.029). Nós concluímos que é possível a medida da acuidade visual de resolução pelos PVEs de varredura em crianças com diagnóstico de hidrocefalia e os valores geralmente são piores comparando aos valores normativos. O tempo da derivação e o número de complicações decorrentes da DVP parecem interferir nesta diferença. Em nosso conhecimento, este foi o primeiro trabalho a avaliar progressivamente, a acuidade visual de crianças, nos primeiros anos de vida, com hidrocefalia, com ou sem DVP e correlacionar o resultado com o tempo de derivações e número de complicações. Apesar da grande evolução tecnológica alcançada pela oftalmologia, ainda não somos capazes de prevenir as alterações visuais detectáveis pelo simples exame de AV nas crianças com hidrocefalia. O tempo para a inserção da válvula de derivação e o tratamento para as complicações ainda são medidas retardadas devido à prematuridade, instabilidade hemodinâmica e a não autorização do familiar. Estes motivos podem comprometer o desenvolvimento visual destas crianças. / The objective was to measure the visual acuity (VA) of children with the diagnosis of hydrocephalus with or without peritoneal-ventricular shunt (PVS). A total of 55 children with the diagnosis of hydrocephalus (45 with PVS and 10 without PVS) were included in the study (34F and 21M), with an age range of 0 to 291 weeks (mean=74 weeks). The VA was measured by the sweep visual evoked potential technique and the results were compared with reference values proposed by Norcia (1985b). Etiological diagnosis of the hydrocephalus was as follows: intracranial hemorrhage (25 children), meningomyelocele (20 children) and congenital hydrocephalus (10 children). The diagnosis of hydrocephalus was made in an average time of 16 days of life. After the diagnosis, the insertion of the PVS, when made, was accomplished in average on the 16th day. Of those with a PVS, in 31 the ventricular valve was inserted before 15 days after the diagnosis whereas in 14 in shunt was inserted after 15 days. Of the 55 children evaluated in the first exam, 18 were evaluated in a second exam, 13 did the third exam, 10 completed 4 exams and only 5 completed the 5 evaluations. The results of the 101 sweep visual evoked potential performed in all children, 95 exams (94%) were abnormal and only 6 were normal. There was no statistical difference in the VA of children without a ventricular shunt in comparison with those in which the shunt was inserted after 15 days of the diagnosis of hydrocephalus (p=0.699). There was, however, a statistical difference in the VA between children with a ventricular shunt inserted before 15 days of the diagnosis and children with a ventricular shunt after 15 days (p=0.038) or those without a shunt (p=0.031). Children with no complications of the ventricular shunt had a better VA as compared to those with shunt complications (p= 0.0001). In the group of children with complications, again those who had a shunt inserted before 15 days bad better VA results in comparison to those in whom the shunt was inserted after 15days (p=0.029). We concluded that measuring visual acuity by sweep visual evoked potential is feasible in children with the diagnosis of hydrocephalus and that results are usually worse comparing with reference values. The timing for insertion of a ventricular shunt and the occurrence of complications of this procedure are factors that may influence the VA. To our knowledge, this is the first study that progressively evaluated the VA in children, of early age, with hydrocephalus, with or without a ventricular shunt and correlated the VA with the timing and complications of the ventricular shunt. Despite the great technological advance in ophthalmology, we are still unable to prevent visual impairments, detectable by simple visual acuity tests, in children with hydrocephalus. The timing of the insertion of the ventricular shunt and the adequate treatment of the potential complications may be delayed due to prematurity, hemodynamic instability and family refusal. This delay may compromise the visual development of these children.
|
6 |
Avaliação da acuidade visual de recém-nascidos pequenos para a idade gestacional pelos métodos do potencial visual evocado de varredura e cartões de acuidade de Teller / Evaluation of Visual Acuity in Small-for-Gestational-Age Newborns Using Sweep VEP and Teller Acuity Card MethodsFrança, Valtenice de Cássia Rodrigues de Matos 09 December 2008 (has links)
Objetivo: Avaliar os efeitos da desnutrição intra-uterina na acuidade visual (AV) de resolução de grades pelo Potencial Visual Evocado de Varredura (PVEv) e Cartões de Acuidade de Teller (CAT). Método: Avaliamos a AV de resolução de grades, binocularmente, de 41 recém-nascidos com idade estacional 37 semanas, destes 23 nasceram com o peso adequado para a idade gestacional (AIG - Idade: 14,3 ± 7,5 semanas) e 18 nasceram pequenos para a idade gestacional (PIG - Idade: 10,7 ± 4,1semanas). A AV foi determinada usando ambas as técnicas psicofísica (CAT) e eletrofisiológica (PVEv). Durante o teste dos CAT foram apresentados cartões contendo em um dos lados grades de ondas quadradas pretas e brancas com freqüência espacial entre 0,23 e 19 ciclos por grau de ângulo visual a 55 cm do participante. O teste iniciou com o cartão com a freqüência espacial mais baixa com orientação randômica desconhecida pelo experimentador. Cartões contendo freqüências espaciais mais altas foram apresentados gradativamente até que uma resposta incorreta ocorresse, então o cartão anterior era apresentado novamente. A AV foi definida pela média aritmética das freqüências espaciais contidas nos cartões para 4 reversões. Para o registro do PVEv, o sistema PowerDiva (Brosnahan et al., 1998) foi usado para gerar todos os estímulos e analisar as repostas provocadas. Estímulos de grades senoidais em reversão de fase em 3, 6 ou 10 Hz foram apresentados em monitor de vídeo monocromático de 21 polegadas com luminância média de 161,13 cd/m2. Registramos o eletroencefalograma com três eletrodos ativos (O1, Oz, O2) relacionados ao eletrodo de referência no vertex. Durante cada tentativa com duração de 10 segundos, resentávamos uma faixa de freqüência espacial que aumentava linearmente. Para cada condição (freqüência temporal - FT) foram usadas no mínimo três tentativas para estimar o limiar. Consideramos o canal que registrou a AV mais alta com boa razão sinal-ruído (SNR>3:1), fase constante e critério estatístico. Resultados: Não encontramos diferenças significativas na AV entre os grupos para nenhum dos métodos. Para o PVEv, não encontramos diferenças significativas na AV, amplitude, ruído ou SNR entre os grupos para nenhuma das FT. Análises intra-grupos mostraram que os valores de amplitude, SNR e ruído foram significativamente diferentes entre as freqüências temporais apenas para os PIG. Entretanto, os PIG até 8 semanas de idade mostraram uma tendência para amplitudes e SNR mais altas para a FT de 3 Hz comparadas aos AIG. Esses mesmos PIG mostraram uma tendência para valores de fase maiores respostas lentas) em comparação aos AIG. Entretanto, a taxa de desenvolvimento da fase foi maior para os PIG do que para os AIG em todas as FT. Conclusão. Não há alteração significativa na AV de recém-nascidos PIG, entretanto as informações de medidas supra-limiares são consistentes com a hipótese que a desnutrição intra-uterina torna as respostas visuais mais lentas entre a retina e o córtex visual. Os dados também sugerem de forma sutil que tais efeitos são passageiros afetando primariamente o grupo de recém-nascidos mais jovens e que o sistema visual dos PIG tem plasticidade suficiente para atingir rapidamente os níveis normais. Mais dados serão necessários para validar esta interpretação. / Objective: To evaluate the effects of intra-uterine malnutrition on grating visual acuity (VA) using Sweep VEP and Teller Acuity Cards (TAC). Method: Binocular grating acuity was evaluated in 41 newborns with gestational age 37 weeks. Twentythree were born with appropriate weight for gestational age (AGA age: 14.3 ± 7.5 weeks) and 18 were born small for gestational age (SGA age: 10.7 ± 4.1 weeks). Visual acuity was determined using both psychophysical (Teller Acuity Cards) and electrophysiological (sVEP) techniques. For the TAC evaluation, cards having calibrated black and white square waves gratings at spatial frequencies (SFs) between 0.23 and 19 cycles/degree were presented 55 cm from the subject. The test began with the lowest SF card in random orientation to which the experimenter was blind. Subsequent cards were presented in order of increasing SF until an incorrect response was made, at which time the prior (lower-SF) card was presented again. Visual acuity was defined as the average of the SF values for 4 reversals. For the sVEP recordings, the PowerDIVA VEP system (Brosnahan et al., 1998) was used to generate all stimuli and analyze the evoked responses. Stimuli were spatial luminance sinewave gratings presented on a 21-inch monochromatic high-resolution monitor (1600x1200 pixels) with an average luminance of 161.1 cd/m2. Gratings were phase-reversed at either 3, 6 or 10 Hz. The electroencephalogram was recorded using 3 active electrodes (O1,Oz,O2) related to the reference electrode at vertex. During each 10-sec sVEP trial a linear sweep of increasing SF was presented. Sweep ranges were selected according to the subjects age. For each condition (each TF), a minimum of 3 trials were used to estimate thresholds, but the majority of measures were the result of a vector average of 5 to 10 trials. For each condition, the acuity estimate used derived from the channel with the highest acuity with statistically significant signal-to-noise ratio (>3:1) and stable phase during the high-SNR portion of the response. Results: There were no statistical differences in visual acuity between the two groups (SGA and AGA) for either method (sVEP or TAC). For the sVEP, acuities were not statistically different for the different TFs. There were also no statistical differences between groups for the sVEP measures of amplitude, phase, noise or signal-to-noise ratio. Intra-group analysis of the sVEP measures at the three TFs revealed statistical differences for amplitude, noise and signal-to-noise ratio, but only for SGA group. However, the SGA subjects less than or equal to 8 weeks of age showed a tendency for higher amplitudes and SNR for 3Hz temporal frequency compared to AGA subjects, and these same SGA subjects showed tendency for larger phase values (slower responses) compared to AGA. However, phase development rate was faster for SGA than for AGA for all temporal frequencies. Conclusion: There were no significant alterations of visual acuity in SGA babies, but the data from suprathreshold measures are consistent with the hypothesis that intrauterine malnutrition results in slower visual responses between retina and cortex. The data obtained so far suggest that such affects are transient, affecting primarily the younger group of infants, and that the visual system in SGA infants has sufficient plasticity to recover rapidly to normal levels. More data is needed to validate this interpretation of the results.
|
7 |
Desenvolvimento da acuidade visual e sensibilidade ao contraste em recém-nascidos pequenos para a idade gestacional por potenciais visuais evocados de varredura / Development of visual acuity and contrast sensitivity in small-for gestational-age newborns assessed by sweep visual evoked potentialsFrança, Valtenice de Cássia Rodrigues de Matos 10 December 2012 (has links)
Objetivo: Avaliar o desenvolvimento da Acuidade Visual (AV) de resolução de grades e a Sensibilidade ao Contraste (SC) de recém-nascidos de termo pequenos para a idade gestacional (PIG). Método: Medimos a AV e a SC de 126 recém-nascidos de termo com o potencial visual evocado de varredura (PVEv; Norcia & Tyler 1985). 73 recém-nascidos (Média de Idade = 11,3 ± 4,3 semanas) nasceram com o peso adequado para a idade gestacional - AIG (percentil 10; Alexander et al., 1996) e 53 recém-nascidos (Média de Idade = 9,2± 3,8 semanas) nasceram pequenos para a idade gestacional - PIG (percentil <10). Mediu-se o PVEv com o sistema PowerDiva (Norcia & Tyler, 1985; Chen et al., 2005) o qual gerou os estímulos e analisou as respostas provocadas. O PVEv foi registrado com três canais unipolares colocados em O1, Oz, and O2 relacionados ao eletrodo de referência no vertex. Utilizaram-se os estímulos de grades senoidais verticais em reversão de fase em 6 Hz com a luminância média de 161 cd/m2. Para medir a AV, o contraste de 80% era mantido fixo e a freqüência espacial aumentava linearmente em intervalos de 1 segundo, durante 10 segundos. Para avaliar a SC, a freqüência espacial de 0,5 cpg era mantida fixa e o contraste aumentava logaritmicamente em intervalos de 1 segundo, durante 10 segundos. Os resultados de ambas as funções visuais foram baseados na média vetorial de pelo menos três tentativas do PVEv. Analisou-se, também, a média do ruído e quatro medidas supralimiares: amplitude máxima (Amáx), razão sinal-ruído em Amáx (SNRmáx), fase em Amáx (máx) e a inclinação da reta do PVEv. Considerou-se o canal que registrou a AV e a SC mais alta, satisfazendo o critério rigoroso de fase e amplitude para assegurar que as respostas corticais eram confiáveis e significativamente acima do ruído. Resultados: O teste Qui-quadrado mostrou que uma proporção significativa de recém-nascidos PIG menores de 9 semanas de idade apresentava valores de AV e SC abaixo da média do grupo AIG com o peso ao nascimento igual ou acima do percentil 50 (P50). Além disso, nas medidas de AV, uma proporção significativa de recémnascidos PIG de 5 a 24 semanas de idade apresentava valores de Amáx, ruído médio e SNRmáx significativamente menores que a média do grupo AIG (P50). A ANOVA fatorial confirmou que a AV, SC, ruído médio e todas as medidas supralimiares apresentaram um desenvolvimento significativo, isto é, as médias dos valores para os recém-nascidos abaixo de 10 semanas de idade apresentavam-se significativamente menores do que as médias dos valores entre 10 e 24 semanas de idade. Além disso, a taxa de desenvolvimento de máx era semelhante para os dois grupos, assim como para os dados de desenvolvimento de fase de Hamer e Norcia (1994). Conclusões: Os recém-nascidos de termo pequenos para a idade gestacional apresentaram alterações no desenvolvimento da acuidade visual de resolução de grades e sensibilidade ao contraste para frequência espacial baixa, principalmente nos 2 primeiros meses de vida quando as alterações nos limiares foram mais evidentes. Além disso, as alterações significativas encontradas para o ruído médio e amplitudes supralimiares durante os seis primeiros meses de vida, mostram que mesmo se os limiares de acuidade visual e contraste não fossem afetados, efeitos neuronais significantes ocorreriam nas vias visuais que conduzem a resposta gerada pelo PVEv (Mirabella et al., 2006) / Objectives: To evaluate the development of cortical grating acuity (VA) and contrast sensitivity (CS) in term infants born small for gestational age (SGA). Methods: Using the sweep visual evoked potential (sVEP; Norcia & Tyler 1985), we measured cortical VA and CS in 126 term infants. Seventy-three (average age = 11.3 ± 4.34 weeks) were born with birthweight within normal limits (> 10th percentile; Alexander et al., 1996). 53 infants were born SGA (average age = 9.2 ± 3.8 weeks). sVEPs were measured using the PowerDiva system (Norcia & Tyler, 1985; Chen et al., 2005) which generated the stimuli and analyzed the evoked responses. The sVEP was recorded using 3 unipolar channels placed at O1, Oz, and O2 with a reference electrode at the vertex. Stimuli were vertical sinewave luminance gratings phase-reversing at 6 Hz with a mean luminance of 161 cd/m2. To measure VA, spatial frequency (SF) was swept linearly from low to high during a 10-second trial, generating ten 1-sec time bins of sVEP data. Grating contrast was fixed at 80% during the SF sweep. To evaluate CS, SF was fixed at 0.5 c/deg, and contrast was increased logarithmically across 10 1-sec recording epochs. The resulting sVEP data from both protocols were based on a vector average of a minimum of 3 sVEP trials. In addition to thresholds, we analyzed average noise (Nav), and 4 suprathreshold measures - peak amplitude (Apeak), signal-to-noise ratio at Apeak (SNRpeak), phase at Apeak (peak) and slope of the rising phase of the sVEP (m). The data used were those obtained from the recording channel generating the highest VA or CS while satisfying strict phase and amplitude criteria to ensure that the responses were reliable and significantly above the noise. Results: A Chi-squared test showed that a significant proportion of the young ( 9 weeks) SGA infants had values of VA and CS that were below the mean of control infants (with birthweights above the international 50th percentile). In addition, mean Nav, Apeak and SNRpeak for the whole group of SGA infants were below the means of control infants across the whole age range tested. A factorial ANOVA confirmed that VA, CS, Nav and all the suprathreshold measures underwent significant development; that is, the mean values prior to 10 weeks were significantly different than the mean values between 10 and 24 weeks. In addition, the rate of development of peak was similar for the two groups as well as to prior phase-development data Hamer and Norcia (1994). Conclusions: Birth at term with weight small for gestational age appears to significantly affect development of both cortical grating acuity and contrast sensitivity for low-SF gratings. Effects on thresholds are most evident in the first 2 months. Moreover, the significant effects we found in Nav and suprathreshold amplitudes throughout the first 6 months of life show that, even if acuity and contrast thresholds are not affected, significant neuronal effects occur in the visual pathways leading to the sVEP signal (Mirabella et al., 2006)
|
8 |
Desenvolvimento das funções de acuidade visual e sensibilidade ao contraste visual medidas por potenciais visuais provocados de varredura em crianças nascidas a termo e prematuras / Development of visual acuity functions and visual contrast sensitivity mesaured by visual evoked potentials in premature and term babiesOliveira, André Gustavo Fernandes de 08 August 2007 (has links)
A prematuridade ao nascimento é um fator de risco para a visão, podendo causar retinopatia, uma condição em que há descolamento da retina. Retinopatia da prematuridade ocorre em uma parcela relativamente pequena dos recém nascidos prematuros e não sabemos se os demais, cujo desenvolvimento visual é aparentemente normal, seguem de fato o mesmo curso que o observado em bebes nascidos após uma gestação completa, ou se também sofrem algum prejuízo devido ao nascimento prematuro. Alternativamente, estes bebês poderiam ter um desenvolvimento visual acelerado pela sua exposição mais longa ao mundo visual. Para saber se a condição de prematuridade acelera, retarda, ou não altera o desenvolvimento da visão, o presente trabalho comparou o desenvolvimento das funções de acuidade visual e de sensibilidade ao contraste espacial de luminância em bebês nascidos prematuros e a termo. O estudo utilizou o método dos Potenciais Visuais Corticais Provocados de Varredura para examinar essas funções. Possíveis correlações entre os limiares visuais obtidos durante o primeiro ano de vida e idade gestacional, índices de Apgar, e valores de peso ao nascimento, foram examinadas. Os participantes foram 57 bebês de ambos os sexos encaminhados pelo Hospital Universitário da Universidade de São Paulo, dos quais 31 prematuros e 26 nascidos a termo. As avaliações foram realizadas principalmente em 3 fases do desenvolvimento visual: 4, 6 e 12 meses de vida. Os bebês prematuros tiveram suas idades corrigidas com relação à idade gestacional para a comparação com os grupos de termos. Um grupo de 14 sujeitos adultos também foi avaliado com os mesmos estímulos visuais. As avaliações das funções de acuidade visual e sensibilidade ao contraste foram realizadas através do método de potenciais visuais corticais provocados de varredura. Eletrodos posicionados no escalpo da região occipital dos pacientes captaram as respostas eletrofisiológicas provocadas por estímulos gerados em um monitor de alta resolução por um sistema computadorizado (sistema NuDiva). Estes estímulos consistiam de grades quadradas com valor de contraste fixo (80%) para avaliação da acuidade visual, e grades senoidais de 4 freqüências espaciais: 0,2 , 0,8 , 2,0 e 4,0 ciclos por grau para a avaliação da sensibilidade ao contraste. Prematuros e termos não apresentaram diferenças estatísticas significantes nas funções visuais avaliadas em nenhuma fase do desenvolvimento. O pico de sensibilidade ao contraste ocorreu entre .8 e 2.0 cpg de 4 meses de idade. No sexto mês o pico deslocou-se para 2.0 cpg, e entre os meses 9 e 12 passou para freqüências espaciais mais altas, por volta de 4.0 cpg coincidindo com o pico encontrado para os adultos. Nossos dados sugerem que nem a experiência visual, maior nos prematuros em relação aos termos, nem o tempo de gestação, maior nos termos em relação aos prematuros, afetam o desenvolvimento da visão espacial em humanos. / Prematurity at birth is a risk factor for vision, since it may lead to retinopathy - a condition in which there is retinal detachment. Retinopathy of prematurity occurs in a relatively small percentage of premature infants and it is not known if the remainder, whose visual development is apparently normal, follow the same course as in term babies after a complete gestational period, or if they also suffer some loss from having been born before complete development. Alternatively, these babies might have an accelerated visual development due to their longer exposure to the visual world, compared to term babies. To examine if prematurity accelerates, slows down, or does not affect visual development, the present study compared the development of visual acuity and contrast sensitivity in premature and term babies. The study used the methodology of the sweep visual evoked potentials to examine these functions. Possible correlations between visual thresholds obtained during the first year of life and gestational age, apgar index and birth weight, were examined. Participants were 57 infants of both genders, recruited by the University Hospital of São Paulo University, of which 31 were prematurely born and 26 were term infants. Evaluations were performed at three visual developmental epochs: 4, 6 e 12 months of age. The age of preterm infants was corrected by their gestational ages in order to allow comparison with the term infants. Another group with 14 adult subjects was tested with the same visual stimulus. Visual acuity and contrast sensitivity tests were performed with the sweep visual evoked potential method. Electrodes placed over the infant\'s scalp at the occipital role recorded electrophysiological responses evoked to visual stimuli generated by a high resolution monitor of a computerized system. The stimuli were square wave gratings with 80% of contrast to evaluate visual acuity, and sine wave gratings of 4 spatial frequencies: 0,2 , 0,8 , 2,0 e 4,0 cycles per degree to evaluate contrast sensitivity. Preterm and term infants did not show statistical differences in the evaluated visual functions in any developmental phase. The contrast sensitivity peak occurred between 0.8 and 2.0 cpd at 4 months of age. At the sixth month the peak moved to 2.0 cpd and it was displaced to a higher spatial frequency (4.0 cpd) at 12 months, where it coincides with the adult SCS peak. Our data suggest that neither visual experience, longer in the preterm, nor gestational age, longer in the term infants, seems to affect spatial vision functions in humans.
|
9 |
Desenvolvimento da acuidade visual e sensibilidade ao contraste em recém-nascidos pequenos para a idade gestacional por potenciais visuais evocados de varredura / Development of visual acuity and contrast sensitivity in small-for gestational-age newborns assessed by sweep visual evoked potentialsValtenice de Cássia Rodrigues de Matos França 10 December 2012 (has links)
Objetivo: Avaliar o desenvolvimento da Acuidade Visual (AV) de resolução de grades e a Sensibilidade ao Contraste (SC) de recém-nascidos de termo pequenos para a idade gestacional (PIG). Método: Medimos a AV e a SC de 126 recém-nascidos de termo com o potencial visual evocado de varredura (PVEv; Norcia & Tyler 1985). 73 recém-nascidos (Média de Idade = 11,3 ± 4,3 semanas) nasceram com o peso adequado para a idade gestacional - AIG (percentil 10; Alexander et al., 1996) e 53 recém-nascidos (Média de Idade = 9,2± 3,8 semanas) nasceram pequenos para a idade gestacional - PIG (percentil <10). Mediu-se o PVEv com o sistema PowerDiva (Norcia & Tyler, 1985; Chen et al., 2005) o qual gerou os estímulos e analisou as respostas provocadas. O PVEv foi registrado com três canais unipolares colocados em O1, Oz, and O2 relacionados ao eletrodo de referência no vertex. Utilizaram-se os estímulos de grades senoidais verticais em reversão de fase em 6 Hz com a luminância média de 161 cd/m2. Para medir a AV, o contraste de 80% era mantido fixo e a freqüência espacial aumentava linearmente em intervalos de 1 segundo, durante 10 segundos. Para avaliar a SC, a freqüência espacial de 0,5 cpg era mantida fixa e o contraste aumentava logaritmicamente em intervalos de 1 segundo, durante 10 segundos. Os resultados de ambas as funções visuais foram baseados na média vetorial de pelo menos três tentativas do PVEv. Analisou-se, também, a média do ruído e quatro medidas supralimiares: amplitude máxima (Amáx), razão sinal-ruído em Amáx (SNRmáx), fase em Amáx (máx) e a inclinação da reta do PVEv. Considerou-se o canal que registrou a AV e a SC mais alta, satisfazendo o critério rigoroso de fase e amplitude para assegurar que as respostas corticais eram confiáveis e significativamente acima do ruído. Resultados: O teste Qui-quadrado mostrou que uma proporção significativa de recém-nascidos PIG menores de 9 semanas de idade apresentava valores de AV e SC abaixo da média do grupo AIG com o peso ao nascimento igual ou acima do percentil 50 (P50). Além disso, nas medidas de AV, uma proporção significativa de recémnascidos PIG de 5 a 24 semanas de idade apresentava valores de Amáx, ruído médio e SNRmáx significativamente menores que a média do grupo AIG (P50). A ANOVA fatorial confirmou que a AV, SC, ruído médio e todas as medidas supralimiares apresentaram um desenvolvimento significativo, isto é, as médias dos valores para os recém-nascidos abaixo de 10 semanas de idade apresentavam-se significativamente menores do que as médias dos valores entre 10 e 24 semanas de idade. Além disso, a taxa de desenvolvimento de máx era semelhante para os dois grupos, assim como para os dados de desenvolvimento de fase de Hamer e Norcia (1994). Conclusões: Os recém-nascidos de termo pequenos para a idade gestacional apresentaram alterações no desenvolvimento da acuidade visual de resolução de grades e sensibilidade ao contraste para frequência espacial baixa, principalmente nos 2 primeiros meses de vida quando as alterações nos limiares foram mais evidentes. Além disso, as alterações significativas encontradas para o ruído médio e amplitudes supralimiares durante os seis primeiros meses de vida, mostram que mesmo se os limiares de acuidade visual e contraste não fossem afetados, efeitos neuronais significantes ocorreriam nas vias visuais que conduzem a resposta gerada pelo PVEv (Mirabella et al., 2006) / Objectives: To evaluate the development of cortical grating acuity (VA) and contrast sensitivity (CS) in term infants born small for gestational age (SGA). Methods: Using the sweep visual evoked potential (sVEP; Norcia & Tyler 1985), we measured cortical VA and CS in 126 term infants. Seventy-three (average age = 11.3 ± 4.34 weeks) were born with birthweight within normal limits (> 10th percentile; Alexander et al., 1996). 53 infants were born SGA (average age = 9.2 ± 3.8 weeks). sVEPs were measured using the PowerDiva system (Norcia & Tyler, 1985; Chen et al., 2005) which generated the stimuli and analyzed the evoked responses. The sVEP was recorded using 3 unipolar channels placed at O1, Oz, and O2 with a reference electrode at the vertex. Stimuli were vertical sinewave luminance gratings phase-reversing at 6 Hz with a mean luminance of 161 cd/m2. To measure VA, spatial frequency (SF) was swept linearly from low to high during a 10-second trial, generating ten 1-sec time bins of sVEP data. Grating contrast was fixed at 80% during the SF sweep. To evaluate CS, SF was fixed at 0.5 c/deg, and contrast was increased logarithmically across 10 1-sec recording epochs. The resulting sVEP data from both protocols were based on a vector average of a minimum of 3 sVEP trials. In addition to thresholds, we analyzed average noise (Nav), and 4 suprathreshold measures - peak amplitude (Apeak), signal-to-noise ratio at Apeak (SNRpeak), phase at Apeak (peak) and slope of the rising phase of the sVEP (m). The data used were those obtained from the recording channel generating the highest VA or CS while satisfying strict phase and amplitude criteria to ensure that the responses were reliable and significantly above the noise. Results: A Chi-squared test showed that a significant proportion of the young ( 9 weeks) SGA infants had values of VA and CS that were below the mean of control infants (with birthweights above the international 50th percentile). In addition, mean Nav, Apeak and SNRpeak for the whole group of SGA infants were below the means of control infants across the whole age range tested. A factorial ANOVA confirmed that VA, CS, Nav and all the suprathreshold measures underwent significant development; that is, the mean values prior to 10 weeks were significantly different than the mean values between 10 and 24 weeks. In addition, the rate of development of peak was similar for the two groups as well as to prior phase-development data Hamer and Norcia (1994). Conclusions: Birth at term with weight small for gestational age appears to significantly affect development of both cortical grating acuity and contrast sensitivity for low-SF gratings. Effects on thresholds are most evident in the first 2 months. Moreover, the significant effects we found in Nav and suprathreshold amplitudes throughout the first 6 months of life show that, even if acuity and contrast thresholds are not affected, significant neuronal effects occur in the visual pathways leading to the sVEP signal (Mirabella et al., 2006)
|
10 |
Avaliação da acuidade visual de recém-nascidos pequenos para a idade gestacional pelos métodos do potencial visual evocado de varredura e cartões de acuidade de Teller / Evaluation of Visual Acuity in Small-for-Gestational-Age Newborns Using Sweep VEP and Teller Acuity Card MethodsValtenice de Cássia Rodrigues de Matos França 09 December 2008 (has links)
Objetivo: Avaliar os efeitos da desnutrição intra-uterina na acuidade visual (AV) de resolução de grades pelo Potencial Visual Evocado de Varredura (PVEv) e Cartões de Acuidade de Teller (CAT). Método: Avaliamos a AV de resolução de grades, binocularmente, de 41 recém-nascidos com idade estacional 37 semanas, destes 23 nasceram com o peso adequado para a idade gestacional (AIG - Idade: 14,3 ± 7,5 semanas) e 18 nasceram pequenos para a idade gestacional (PIG - Idade: 10,7 ± 4,1semanas). A AV foi determinada usando ambas as técnicas psicofísica (CAT) e eletrofisiológica (PVEv). Durante o teste dos CAT foram apresentados cartões contendo em um dos lados grades de ondas quadradas pretas e brancas com freqüência espacial entre 0,23 e 19 ciclos por grau de ângulo visual a 55 cm do participante. O teste iniciou com o cartão com a freqüência espacial mais baixa com orientação randômica desconhecida pelo experimentador. Cartões contendo freqüências espaciais mais altas foram apresentados gradativamente até que uma resposta incorreta ocorresse, então o cartão anterior era apresentado novamente. A AV foi definida pela média aritmética das freqüências espaciais contidas nos cartões para 4 reversões. Para o registro do PVEv, o sistema PowerDiva (Brosnahan et al., 1998) foi usado para gerar todos os estímulos e analisar as repostas provocadas. Estímulos de grades senoidais em reversão de fase em 3, 6 ou 10 Hz foram apresentados em monitor de vídeo monocromático de 21 polegadas com luminância média de 161,13 cd/m2. Registramos o eletroencefalograma com três eletrodos ativos (O1, Oz, O2) relacionados ao eletrodo de referência no vertex. Durante cada tentativa com duração de 10 segundos, resentávamos uma faixa de freqüência espacial que aumentava linearmente. Para cada condição (freqüência temporal - FT) foram usadas no mínimo três tentativas para estimar o limiar. Consideramos o canal que registrou a AV mais alta com boa razão sinal-ruído (SNR>3:1), fase constante e critério estatístico. Resultados: Não encontramos diferenças significativas na AV entre os grupos para nenhum dos métodos. Para o PVEv, não encontramos diferenças significativas na AV, amplitude, ruído ou SNR entre os grupos para nenhuma das FT. Análises intra-grupos mostraram que os valores de amplitude, SNR e ruído foram significativamente diferentes entre as freqüências temporais apenas para os PIG. Entretanto, os PIG até 8 semanas de idade mostraram uma tendência para amplitudes e SNR mais altas para a FT de 3 Hz comparadas aos AIG. Esses mesmos PIG mostraram uma tendência para valores de fase maiores respostas lentas) em comparação aos AIG. Entretanto, a taxa de desenvolvimento da fase foi maior para os PIG do que para os AIG em todas as FT. Conclusão. Não há alteração significativa na AV de recém-nascidos PIG, entretanto as informações de medidas supra-limiares são consistentes com a hipótese que a desnutrição intra-uterina torna as respostas visuais mais lentas entre a retina e o córtex visual. Os dados também sugerem de forma sutil que tais efeitos são passageiros afetando primariamente o grupo de recém-nascidos mais jovens e que o sistema visual dos PIG tem plasticidade suficiente para atingir rapidamente os níveis normais. Mais dados serão necessários para validar esta interpretação. / Objective: To evaluate the effects of intra-uterine malnutrition on grating visual acuity (VA) using Sweep VEP and Teller Acuity Cards (TAC). Method: Binocular grating acuity was evaluated in 41 newborns with gestational age 37 weeks. Twentythree were born with appropriate weight for gestational age (AGA age: 14.3 ± 7.5 weeks) and 18 were born small for gestational age (SGA age: 10.7 ± 4.1 weeks). Visual acuity was determined using both psychophysical (Teller Acuity Cards) and electrophysiological (sVEP) techniques. For the TAC evaluation, cards having calibrated black and white square waves gratings at spatial frequencies (SFs) between 0.23 and 19 cycles/degree were presented 55 cm from the subject. The test began with the lowest SF card in random orientation to which the experimenter was blind. Subsequent cards were presented in order of increasing SF until an incorrect response was made, at which time the prior (lower-SF) card was presented again. Visual acuity was defined as the average of the SF values for 4 reversals. For the sVEP recordings, the PowerDIVA VEP system (Brosnahan et al., 1998) was used to generate all stimuli and analyze the evoked responses. Stimuli were spatial luminance sinewave gratings presented on a 21-inch monochromatic high-resolution monitor (1600x1200 pixels) with an average luminance of 161.1 cd/m2. Gratings were phase-reversed at either 3, 6 or 10 Hz. The electroencephalogram was recorded using 3 active electrodes (O1,Oz,O2) related to the reference electrode at vertex. During each 10-sec sVEP trial a linear sweep of increasing SF was presented. Sweep ranges were selected according to the subjects age. For each condition (each TF), a minimum of 3 trials were used to estimate thresholds, but the majority of measures were the result of a vector average of 5 to 10 trials. For each condition, the acuity estimate used derived from the channel with the highest acuity with statistically significant signal-to-noise ratio (>3:1) and stable phase during the high-SNR portion of the response. Results: There were no statistical differences in visual acuity between the two groups (SGA and AGA) for either method (sVEP or TAC). For the sVEP, acuities were not statistically different for the different TFs. There were also no statistical differences between groups for the sVEP measures of amplitude, phase, noise or signal-to-noise ratio. Intra-group analysis of the sVEP measures at the three TFs revealed statistical differences for amplitude, noise and signal-to-noise ratio, but only for SGA group. However, the SGA subjects less than or equal to 8 weeks of age showed a tendency for higher amplitudes and SNR for 3Hz temporal frequency compared to AGA subjects, and these same SGA subjects showed tendency for larger phase values (slower responses) compared to AGA. However, phase development rate was faster for SGA than for AGA for all temporal frequencies. Conclusion: There were no significant alterations of visual acuity in SGA babies, but the data from suprathreshold measures are consistent with the hypothesis that intrauterine malnutrition results in slower visual responses between retina and cortex. The data obtained so far suggest that such affects are transient, affecting primarily the younger group of infants, and that the visual system in SGA infants has sufficient plasticity to recover rapidly to normal levels. More data is needed to validate this interpretation of the results.
|
Page generated in 0.1051 seconds