• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • Tagged with
  • 7
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Atributos da validação do método analítico para quantificação da biotina empregando a técnica potenciométrica

Gonçalves, Gabriela Soldi [UNESP] 20 December 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:18Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-12-20Bitstream added on 2014-06-13T20:28:32Z : No. of bitstreams: 1 goncalves_gs_me_arafcf.pdf: 376750 bytes, checksum: d261fb301fa1b4c966236fbf2eb5c9d0 (MD5) / Universidade Estadual Paulista (UNESP) / O presente trabalho consiste no desenvolvimento de um método analítico para determinação de biotina, utilizando-se a potenciometria indireta. O objetivo é apresentar a validação de método analítico como um processo que estime a eficiência do método proposto na rotina do laboratório para garantia da qualidade total. É um método que envolve equipamento simples e pouco dispendioso como o potenciômetro, que possibilita medir com precisão o valor da concentração de biotina. O doseamento quantitativo de biotina baseia-se no estudo das reações oscilantes do analito perante as análises da titulação indireta utilizando potenciômetro automático. A concentração de biotina foi determinada com massa adicionada conhecida numa matriz que simula uma cápsula, contendo aerosil (1%), estearato de magnésio (1%), celulose microcristalina (20%), amido (40%) e lactose q.s.p. Os resultados mostraram um valor médio de biotina (massa adicionada de aproximadamente 25 mg) determinada de 99,4% com desvio-padrão de 0,0345. As condições experimentais como temperatura, vidraria e concentração dos reagentes foram otimizadas. Os parâmetros investigados no processo de validação para demonstrar o desempenho do método foram: especificidade, linearidade, intervalo, precisão tanto repetitividade, quanto intermediária, exatidão e robustez. O tratamento estatístico dos dados da validação do método analítico envolveu a determinação da média, do desvio padrão e do coeficiente de variação. Para obtenção da curva de calibração se fez necessária a determinação da equação da reta, regressão linear e coeficiente de correlação linear. Este método apresenta grande aplicabilidade em soluções turvas, fluorescentes, opacas ou coradas, ou quando não existem, ou não podem aplicar-se indicadores visuais apropriados. Há possibilidade de determinação... / The present work shows the development of an analytical method for the determination of biotin by using indirect potentiometry. The main goal is to present the validation of analytical methods as a process to estimate the efficiency of the proposed methodology in the laboratory routine for the guaranty of total quality. This method involves simple and low cost devices as the potentiometer, which allows the precise measurement of biotin concentration. The quantitative dosing of biotin is based on the study of the oscillating chemical reactions with the analyte by performing the analysis of the indirect titration with an automatic potentiometer. Biotin concentration was determined by adding a known mass to a matrix that simulates a capsule containing aerosol (1%), estearato de magnésio (1%), celulose microcristalina (20%), amido (40%) e lactose q.s.p. The results showed an average value for the determination of biotin (added mass was ca. 25 mg) of 99.4% with a standard deviation of 0.0345. The experimental conditions as temperature, glassware, and concentration of the chemicals were optimized. The investigated parameters of the validation procedure to demonstrate the performance of the method were: specificity, linearity, interval, precision (repeatability and intermediate), exactness and robustness. The statistical treatment of the data for the validation of the analytical method involved the determination of the average value, standard deviation, and the variation coefficient. In order to obtain the calibration curve, the line´s equation, the linear regression and the coefficient of linear correlation were determined. This method shows great applicability for turbid, fluorescent, opaque or color solutions, or if an appropriate visual indicator is not available or cannot be applied. The method also shows the possibility for the determination of a sequence of equivalence... (Complete abstract click electronic access below)
2

Tratamento de dados em multiescala utlizando transformada wavelet para localização de ontos de inflexão em curvas de análise por redissolução potenciométrica

Lacerda Martins, Valdomiro January 2005 (has links)
Made available in DSpace on 2014-06-12T23:15:39Z (GMT). No. of bitstreams: 2 arquivo9239_1.pdf: 1568641 bytes, checksum: 107b83e746d7a76fcdfffb50c2b20304 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Técnicas de análise instrumental que empregam medidas baseadas em pontos de inflexão podem ter sua precisão comprometida devido à necessidade de diferenciação dos sinais analíticos, a qual é muito sensível à presença de ruído instrumental. Para superar este inconveniente, é proposta neste trabalho uma nova estratégia para localização de pontos de inflexão que explora a capacidade de processamento em multiescala da transformada Wavelet (do inglês: Wavelet Transform - WT) evitando a necessidade explicita da diferenciação de sinais analíticos. Para estudar a viabilidade da estratégia WT proposta, ela inicialmente foi utilizada na determinação de pontos de inflexão em curvas sigmoidais simuladas. Os efeitos de ruído e assimetria nas curvas são discutidos. Como resultado, observa-se que a estratégia WT fornece uma estimativa não-tendenciosa do ponto de inflexão, sendo ainda menos afetada pelo ruído que um procedimento baseado na primeira derivada do sinal. Após este estudo preliminar, a utilidade prática da estratégia proposta foi avaliada na determinação de metais em águas usando a técnica de análise por redissolução potenciométrica (do inglês: Potentiometric Stripping Analysis - PSA), cuja precisão é significativamente dependente da localização do ponto de inflexão usado na determinação do parâmetro analítico. Para enfatizar a utilidade da estratégia proposta, foi empregado nas medidas um potenciostato labmade que apresenta sinais consideravelmente ruidosos. Inicialmente foram determinados Pb(II) e Cd(II) em amostras aquosas sintéticas e os resultados obtidos com o uso da estratégia WT proposta foram sempre concordantes os valores esperados. Em seguida, foram determinados Pb(II) e Cu(II) em águas naturais, com resultados concordantes com os obtidos empregando um instrumento comercial, cujo software usa dPSA (Derivative Potentiometric Stripping Analysis) para a determinação do parâmetro analítico. Os desvios padrão obtidos nas análises usando ambas as estratégias foram em média menores que 0,3 μg l-1 e estes podem ser considerados bastantes aceitáveis ao se levar em conta os níveis de concentração encontrados, em torno de 3 a 7 μg l-1 (partes por bilhão ppb), nas determinações de Pb(II) e Cu(II). Diante dos resultados obtidos, tanto nas curvas sigmoidais simuladas, quanto nas determinações por PSA com o potenciostato labmade, pode-se considerar que a estratégia WT proposta é viável, podendo ser usada em quaisquer problemas que involvam a determinação de parâmetros analíticos com base em pontos de inflexão de uma curva
3

Aperfeiçoamento de métodos para a determinação de componentes ácidos e básicos em amostras de água de chuva / Enhancement of methods for the determination of acid and alkaline compounds in rainwater samples

Coelho, Lucia Helena Gomes 14 April 2005 (has links)
O estudo da variação da composição atmosférica contribui para a compreensão dos efeitos das emissões antrópicas sobre a troposfera. A análise química da água de chuva assume importância neste contexto, uma vez que a precipitação úmida constitui um excelente meio de remoção de muitos poluentes da atmosfera. O aumento de acidez das chuvas, em várias partes do planeta, tem sido associado, predominantemente, à presença de ácidos fortes como o sulfúrico e nítrico, e ácidos orgânicos como acético e fórmico, originados pela oxidação de compostos de enxofre, nitrogênio e carbono, respectivamente. Dando continuidade a pesquisas anteriores sobre deposição úmida realizadas no IQ-USP, no presente trabalho buscou-se extrair mais informações de titulações potenciométricas e condutométricas de água de chuva, mediante aperfeiçoamento dos métodos de cálculo, com recursos quimiométricos modernos, de modo a complementar as medidas de pH e condutividade convencionais. As concentrações de espécies ácidas ou básicas nas amostras de água de chuva são da ordem de 10-5 mol L-1, muito abaixo das concentrações empregadas na prática cotidiana das titulações potenciométricas (tipicamente, no intervalo de 10-1 a 10-3 mol L-1). Dessa forma, propôs-se o uso de um método de regressão não linear (RNL) multiparamétrica, baseado no método de Levenberg-Marquardt, para a análise de dados potenciométricos (TP-RNL) após procedimento de transposição de coordenadas das curvas de titulação. Ao lado das determinações das concentrações dos analitos, pôde-se estimar ou refinar as constantes de protonação das bases de Brönsted presentes. Para tanto, procedeu-se ao ajuste por RNL das concentrações e/ou das constantes de protonação das bases presentes, de modo a minimizar o quadrado dos desvios entre os valores experimentais e os calculados em função do titulante adicionado, recorrendo a uma equação geral baseada no número médio de protonação de cada uma das bases. Ficou demonstrada a possibilidade de se determinar a soma de ácidos fortes completamente dissociados, soma de ácidos fracos com pK próximo a 4 (principalmente ácidos acético e fórmico), HCO3-/H2CO3 e a soma de bases fracas com pK ao redor de 9 (essencialmente NH3/NH4+). Durante as titulações, a facilidade em se coletar medidas de condutância simultaneamente às de pH levou a elaboração de um método sofisticado de análise de curvas de titulação condutométrica. Para tanto, desenvolveu-se uma equação de RNL baseada na contribuição das espécies em cada valor de pH e na condutância iônica medida (TC-RNL). A equação de TC-RNL é alimentada por dados de pH em função do titulante adicionado, oriundos de titulações potenciométricas. Dessa forma, foi possível caracterizar diretamente amônio e bicarbonato, além do conteúdo iônico total que não participa dos equilíbrios ácidos/base existentes no sistema. Adicionalmente, foi possível separar a contribuição do ácido acético da do fórmico, tarefa impossível por TP-RNL, ao menos nas baixas concentrações encontradas na chuva. Nas mesmas amostras de chuva tituladas foi procedida a análise por eletroforese capilar de zona com detecção condutométrica sem contato (CZE-CCD), conforme procedimento descrito na literatura, estimando-se os cátions e ânions majoritários. Num aperfeiçoamento do método para ânions, viabilizou-se a determinação simultânea HCO3-. Para validar os resultados obtidos por CZE-CCD, recorreu-se à cromatografia de íons. As concentrações de vários analitos, dependendo das amostras de chuva, avizinham-se do limite de quantificação das técnicas TP-RNL, TC-RNL e CZE-CCD. Mesmo assim, para as amostras de chuva analisadas, em geral, houve concordância satisfatória entre os valores estimados pelas três técnicas para espécies agrupadas da seguinte forma: ácidos fortes, ácidos fracos, amônio e bicarbonato. / Ivestigation of the variability of atmospheric chemical composition is an important tool for the evaluation and comprehension of anthropic emissions effects.Rainwater analysis has great importance in this context because wet deposition represents an efficient removal route of many atmospheric pollutants. The acidification of rainwater over wide regions of the planet is associated with the increased presence of strong acids, like sulfuric and nitric ones, and organic acids, such as acetic and formic, mainly originated from oxidative reactions od sulfur, nitrogen and carbon compounds in the atmosphere. In the context of a broad research line at IQ-USP devoted to the study of wet deposition and associated atmospheric chemistry, this dissertation advances the subject of using moderm chemometric methods to extract reliable analytical information from potentiometric and conductometric titrations of rainwater. The concentrations of acidic and alkaline species in rainwater are typically below 5 x 10-5 mol L-1, out of the reach of conventional potentiometric titrations (widely applied in the range of 10-1 and 10-3 mol L-1). Thus, multiparametric non-linear regression based on Levenberg-Marquardt method combined with coordinates transposition to reduce iterative calculation is proposed for the analysis of potentiometric data (PT-NLR). General equations based on the average protonation number of each base are used to describe the system. Bases concentrations and/or protonation constants are adjusted by NLR in order to minimize the sum-of-squares of the residuals between experimental and calculated values of the titration curves. The data analysis was tuned to provide four parameters as output: the sum of strong acids, the sum of weak acids with pK around 4.2 (mainly acetic and formic acids), the sum of HCO3-/H2co3 and the sum of weak bases with pK near 9 (essentially NH3/NH4+). To extract more analytical information from the acid/base titrations, conductance meassurements were made simultaneously with the pH readings, and a sophisticated data analysis method was envisioned. The pH data and available protonation constants for bases included in the model are used to compute the distribution of the species. The available conductivity of each species of the model is introduced in a general equation where the only unknowns are the total concentrations of the bases and of electrolyte not involved in acid/base equilibria. All these concentrations are adjusted by NLR on the conductance data, resulting in the first successful conductometric titration method with non-linear regression analysis, CT-NLR. The great advantage over PT-NLR was the capability to distinguish the contributions of acetic and formic acids in rainwater (an impossible task in PT-NLR method), but total strong acids, ammonium and bicarbonate are determined as well, beside the total ionic content of species not involved acid-base equilibria. Rainwater samples were also analysed by capillary zone electriphoresis equipment with contactless conductometric detection (CZE-CCD), as decribed in literature, regarding the major cations and anions. An improved CE method for anions was developed to afford the simultaneous determination of HCO3-. Validation of results was made with the reference method of ion chromatography. Although in many samples some analytes are low and close to the quantification limits od CZE-CCD, PT-NLR and CT-NLR, satisfactory agreement was achieved between values obtained by the three techniques for strong acids, weak acids, ammonium and bicarbonate.
4

Aperfeiçoamento de métodos para a determinação de componentes ácidos e básicos em amostras de água de chuva / Enhancement of methods for the determination of acid and alkaline compounds in rainwater samples

Lucia Helena Gomes Coelho 14 April 2005 (has links)
O estudo da variação da composição atmosférica contribui para a compreensão dos efeitos das emissões antrópicas sobre a troposfera. A análise química da água de chuva assume importância neste contexto, uma vez que a precipitação úmida constitui um excelente meio de remoção de muitos poluentes da atmosfera. O aumento de acidez das chuvas, em várias partes do planeta, tem sido associado, predominantemente, à presença de ácidos fortes como o sulfúrico e nítrico, e ácidos orgânicos como acético e fórmico, originados pela oxidação de compostos de enxofre, nitrogênio e carbono, respectivamente. Dando continuidade a pesquisas anteriores sobre deposição úmida realizadas no IQ-USP, no presente trabalho buscou-se extrair mais informações de titulações potenciométricas e condutométricas de água de chuva, mediante aperfeiçoamento dos métodos de cálculo, com recursos quimiométricos modernos, de modo a complementar as medidas de pH e condutividade convencionais. As concentrações de espécies ácidas ou básicas nas amostras de água de chuva são da ordem de 10-5 mol L-1, muito abaixo das concentrações empregadas na prática cotidiana das titulações potenciométricas (tipicamente, no intervalo de 10-1 a 10-3 mol L-1). Dessa forma, propôs-se o uso de um método de regressão não linear (RNL) multiparamétrica, baseado no método de Levenberg-Marquardt, para a análise de dados potenciométricos (TP-RNL) após procedimento de transposição de coordenadas das curvas de titulação. Ao lado das determinações das concentrações dos analitos, pôde-se estimar ou refinar as constantes de protonação das bases de Brönsted presentes. Para tanto, procedeu-se ao ajuste por RNL das concentrações e/ou das constantes de protonação das bases presentes, de modo a minimizar o quadrado dos desvios entre os valores experimentais e os calculados em função do titulante adicionado, recorrendo a uma equação geral baseada no número médio de protonação de cada uma das bases. Ficou demonstrada a possibilidade de se determinar a soma de ácidos fortes completamente dissociados, soma de ácidos fracos com pK próximo a 4 (principalmente ácidos acético e fórmico), HCO3-/H2CO3 e a soma de bases fracas com pK ao redor de 9 (essencialmente NH3/NH4+). Durante as titulações, a facilidade em se coletar medidas de condutância simultaneamente às de pH levou a elaboração de um método sofisticado de análise de curvas de titulação condutométrica. Para tanto, desenvolveu-se uma equação de RNL baseada na contribuição das espécies em cada valor de pH e na condutância iônica medida (TC-RNL). A equação de TC-RNL é alimentada por dados de pH em função do titulante adicionado, oriundos de titulações potenciométricas. Dessa forma, foi possível caracterizar diretamente amônio e bicarbonato, além do conteúdo iônico total que não participa dos equilíbrios ácidos/base existentes no sistema. Adicionalmente, foi possível separar a contribuição do ácido acético da do fórmico, tarefa impossível por TP-RNL, ao menos nas baixas concentrações encontradas na chuva. Nas mesmas amostras de chuva tituladas foi procedida a análise por eletroforese capilar de zona com detecção condutométrica sem contato (CZE-CCD), conforme procedimento descrito na literatura, estimando-se os cátions e ânions majoritários. Num aperfeiçoamento do método para ânions, viabilizou-se a determinação simultânea HCO3-. Para validar os resultados obtidos por CZE-CCD, recorreu-se à cromatografia de íons. As concentrações de vários analitos, dependendo das amostras de chuva, avizinham-se do limite de quantificação das técnicas TP-RNL, TC-RNL e CZE-CCD. Mesmo assim, para as amostras de chuva analisadas, em geral, houve concordância satisfatória entre os valores estimados pelas três técnicas para espécies agrupadas da seguinte forma: ácidos fortes, ácidos fracos, amônio e bicarbonato. / Ivestigation of the variability of atmospheric chemical composition is an important tool for the evaluation and comprehension of anthropic emissions effects.Rainwater analysis has great importance in this context because wet deposition represents an efficient removal route of many atmospheric pollutants. The acidification of rainwater over wide regions of the planet is associated with the increased presence of strong acids, like sulfuric and nitric ones, and organic acids, such as acetic and formic, mainly originated from oxidative reactions od sulfur, nitrogen and carbon compounds in the atmosphere. In the context of a broad research line at IQ-USP devoted to the study of wet deposition and associated atmospheric chemistry, this dissertation advances the subject of using moderm chemometric methods to extract reliable analytical information from potentiometric and conductometric titrations of rainwater. The concentrations of acidic and alkaline species in rainwater are typically below 5 x 10-5 mol L-1, out of the reach of conventional potentiometric titrations (widely applied in the range of 10-1 and 10-3 mol L-1). Thus, multiparametric non-linear regression based on Levenberg-Marquardt method combined with coordinates transposition to reduce iterative calculation is proposed for the analysis of potentiometric data (PT-NLR). General equations based on the average protonation number of each base are used to describe the system. Bases concentrations and/or protonation constants are adjusted by NLR in order to minimize the sum-of-squares of the residuals between experimental and calculated values of the titration curves. The data analysis was tuned to provide four parameters as output: the sum of strong acids, the sum of weak acids with pK around 4.2 (mainly acetic and formic acids), the sum of HCO3-/H2co3 and the sum of weak bases with pK near 9 (essentially NH3/NH4+). To extract more analytical information from the acid/base titrations, conductance meassurements were made simultaneously with the pH readings, and a sophisticated data analysis method was envisioned. The pH data and available protonation constants for bases included in the model are used to compute the distribution of the species. The available conductivity of each species of the model is introduced in a general equation where the only unknowns are the total concentrations of the bases and of electrolyte not involved in acid/base equilibria. All these concentrations are adjusted by NLR on the conductance data, resulting in the first successful conductometric titration method with non-linear regression analysis, CT-NLR. The great advantage over PT-NLR was the capability to distinguish the contributions of acetic and formic acids in rainwater (an impossible task in PT-NLR method), but total strong acids, ammonium and bicarbonate are determined as well, beside the total ionic content of species not involved acid-base equilibria. Rainwater samples were also analysed by capillary zone electriphoresis equipment with contactless conductometric detection (CZE-CCD), as decribed in literature, regarding the major cations and anions. An improved CE method for anions was developed to afford the simultaneous determination of HCO3-. Validation of results was made with the reference method of ion chromatography. Although in many samples some analytes are low and close to the quantification limits od CZE-CCD, PT-NLR and CT-NLR, satisfactory agreement was achieved between values obtained by the three techniques for strong acids, weak acids, ammonium and bicarbonate.
5

Desenvolvimento de métodos eletroanalíticos (análise por redissolução e eletroforese capilar) para a determinação de metais e ânions em combustíveis e derivados de petróleo / Development of electroanalytical methods (Stripping Analysis and Capillary Electrophoresis) for the determination of metals and anions in fuels and petroleum-based products

Muñoz, Rodrigo Alejandro Abarza 15 March 2006 (has links)
Neste trabalho foram desenvolvidos métodos eletroanalíticos (redissolução potenciométrica e voltamétrica) para a determinação de metais (mercúrio, cobre, chumbo e zinco) em petróleo, óleo diesel, óleo lubrificante e álcool combustível. Para analisar álcool, foi também desenvolvido um método por eletroforese capilar, que possibilita a determinação de cátions (sódio, potássio e cálcio) e ânions (cloreto, sulfato e nitrato). Procedimentos envolvendo a utilização de fornos de microondas (focalizadas - que opera a pressão atmosférica - e com cavidade, que promove a digestão em frascos pressurizados) para a decomposição de petróleo, óleo diesel e óleo lubrificante são descritos. As determinações de cobre e mercúrio por redissolução potenciométrica apresentaram melhores limites de detecção do que a voltametria de redissolução de onda quadrada nas amostras digeridas, utilizando eletrodos de ouro confeccionados a partir de CDs graváveis (Cdtrodos), como eletrodo de trabalho. Para a determinação de chumbo e zinco nas mesmas amostras digeridas, os melhores resultados foram obtidos com eletrodos de filme de mercúrio e utilizando a voltametria de redissolução potenciométrica. Perdas de mercúrio por volatilização foram verificadas quando as amostras foram digeridas em fornos de microondas focalizadas. Para os demais metais, a utilização deste forno foi vantajosa por proporcionar melhores limites de detecção devido à utilização de maiores massas de amostra no processo de digestão. A utilização de um banho ultrassônico de bancada para promover a extração de cobre e chumbo de óleos lubrificantes na presença da mistura 1:1 (v/v) de HClconc. e H2O2 (30% m/v) mostrou-se eficiente. Trinta minutos de exposição à energia ultrassônica foram necessários para a extração quantitativa de ambos os metais. Nas soluções extratoras, o teor dos metais foi determinado por voltametria de redissolução anódica, usando CDtrodos. Os limites de detecção do método para a determinação de cobre e chumbo foram, respectivamente, de 23 e 67 ng g-1 de óleo, aplicando 120 s de tempo de deposição. A voltametria de redissolução anódica em eletrodo de ouro possibilitou a determinação de cobre e chumbo em álcool combustível, sem qualquer tratamento prévio das amostras. Limites de detecção de 120 e 235 ng L-1 para cobre e chumbo, respectivamente, foram obtidos aplicando 15 min de tempo de deposição. Alternativamente, a evaporação do etanol seguido da redissolução em água desionizada permitiu a determinação dos metais por análise de redissolução. Todos os resultados obtidos utilizando diferentes metodologias de decomposição de amostras foram comparados com os resultados obtidos por análises por espectrometria de absorção atômica com forno de grafite. O método envolvendo a evaporação prévia, seguida da redissolução dos íons em meio aquoso também se mostrou muito favorável para realizar a determinação de cátions e ânions por eletroforese capilar em amostras de etanol hidratado combustível. Os íons Na+, K+ e Ca2+, Cl-, NO3- e SO42- foram encontrados nas amostras analisadas. Os limites de detecção destes íons se encontram na faixa de 0,06 e 0,18 mg L-1. / In this work eletroanalytical methodologies (potentiometric stripping analysis and anodic stripping voltammetry) for the determination of metals (mercury, copper, lead, and zinc) in crude oil, lubricating oil, diesel fuel, and ethanol fuel are proposed. A capillary electrophoresis method for ethanol fuel was developed to determine cations (sodium, potassium, and calcium) and anions (chloride, sulphate, and nitrate). Microwave digestion methods using different ovens (a focused microwave oven – operating at atmospheric pressure, and a cavity microwave oven, which employs pressurized vessels) for crude oil, lubricating oil, and diesel fuel are described. The determination of copper and mercury by potentiometric stripping analysis presents better detection limits than stripping voltammetric determinations for the digested sample analysis. Loss of mercury by volatilization was verified when samples were digested in the focused microwave oven. Otherwise, this oven presented some advantages for the other metals, as the improved detection limits due to the employment of higher sample mass for the digestion process. The use of a ultrasonic bath to promote the extraction of copper and lead from lubricating oils in the presence of 1:1 (v/v) HClconc and H2O2 (30% m/v) was efficient. Thirty minutes of ultrasonic exposure were necessary for quantitative exctraction of copper and lead. Anodic stripping voltammetry using gold CDtrodes was applied for metal determination in the extracted solutions. The detection limits of the proposed method for copper and lead were 23 and 67 ng g-1, respectively, under application of 120 seconds as deposition time. Anodic stripping voltammetry at a gold electrode was used for the determination of copper and lead in ethanol fuel, without any prior sample treatment. Detection limits of 120 and 235 ng L-1 for copper and lead, respectively, were attained applying 900 s as deposition time. Alternatively, the ethanol evaporation followed by re-suspension in deionised water allowed the metals determination by stripping analysis. All results obtained for sample decomposition methods were compared with the ones obtained by electrothermal atomic absorption spectrometric determinations. The method, which employs prior ethanol evaporation followed by re-suspension in deionised water, was applied for the determination of cations and anions by capillary electrophoresis in the hydrated ethanol fuel (automotive fuel). Na+, K+, Ca2+, Cl-, NO3-, and SO42- ions were found in the analyzed samples. The detection limits for these ions were situated between 0.06 and 0.18 mg L-1.
6

Desenvolvimento de métodos eletroanalíticos (análise por redissolução e eletroforese capilar) para a determinação de metais e ânions em combustíveis e derivados de petróleo / Development of electroanalytical methods (Stripping Analysis and Capillary Electrophoresis) for the determination of metals and anions in fuels and petroleum-based products

Rodrigo Alejandro Abarza Muñoz 15 March 2006 (has links)
Neste trabalho foram desenvolvidos métodos eletroanalíticos (redissolução potenciométrica e voltamétrica) para a determinação de metais (mercúrio, cobre, chumbo e zinco) em petróleo, óleo diesel, óleo lubrificante e álcool combustível. Para analisar álcool, foi também desenvolvido um método por eletroforese capilar, que possibilita a determinação de cátions (sódio, potássio e cálcio) e ânions (cloreto, sulfato e nitrato). Procedimentos envolvendo a utilização de fornos de microondas (focalizadas - que opera a pressão atmosférica - e com cavidade, que promove a digestão em frascos pressurizados) para a decomposição de petróleo, óleo diesel e óleo lubrificante são descritos. As determinações de cobre e mercúrio por redissolução potenciométrica apresentaram melhores limites de detecção do que a voltametria de redissolução de onda quadrada nas amostras digeridas, utilizando eletrodos de ouro confeccionados a partir de CDs graváveis (Cdtrodos), como eletrodo de trabalho. Para a determinação de chumbo e zinco nas mesmas amostras digeridas, os melhores resultados foram obtidos com eletrodos de filme de mercúrio e utilizando a voltametria de redissolução potenciométrica. Perdas de mercúrio por volatilização foram verificadas quando as amostras foram digeridas em fornos de microondas focalizadas. Para os demais metais, a utilização deste forno foi vantajosa por proporcionar melhores limites de detecção devido à utilização de maiores massas de amostra no processo de digestão. A utilização de um banho ultrassônico de bancada para promover a extração de cobre e chumbo de óleos lubrificantes na presença da mistura 1:1 (v/v) de HClconc. e H2O2 (30% m/v) mostrou-se eficiente. Trinta minutos de exposição à energia ultrassônica foram necessários para a extração quantitativa de ambos os metais. Nas soluções extratoras, o teor dos metais foi determinado por voltametria de redissolução anódica, usando CDtrodos. Os limites de detecção do método para a determinação de cobre e chumbo foram, respectivamente, de 23 e 67 ng g-1 de óleo, aplicando 120 s de tempo de deposição. A voltametria de redissolução anódica em eletrodo de ouro possibilitou a determinação de cobre e chumbo em álcool combustível, sem qualquer tratamento prévio das amostras. Limites de detecção de 120 e 235 ng L-1 para cobre e chumbo, respectivamente, foram obtidos aplicando 15 min de tempo de deposição. Alternativamente, a evaporação do etanol seguido da redissolução em água desionizada permitiu a determinação dos metais por análise de redissolução. Todos os resultados obtidos utilizando diferentes metodologias de decomposição de amostras foram comparados com os resultados obtidos por análises por espectrometria de absorção atômica com forno de grafite. O método envolvendo a evaporação prévia, seguida da redissolução dos íons em meio aquoso também se mostrou muito favorável para realizar a determinação de cátions e ânions por eletroforese capilar em amostras de etanol hidratado combustível. Os íons Na+, K+ e Ca2+, Cl-, NO3- e SO42- foram encontrados nas amostras analisadas. Os limites de detecção destes íons se encontram na faixa de 0,06 e 0,18 mg L-1. / In this work eletroanalytical methodologies (potentiometric stripping analysis and anodic stripping voltammetry) for the determination of metals (mercury, copper, lead, and zinc) in crude oil, lubricating oil, diesel fuel, and ethanol fuel are proposed. A capillary electrophoresis method for ethanol fuel was developed to determine cations (sodium, potassium, and calcium) and anions (chloride, sulphate, and nitrate). Microwave digestion methods using different ovens (a focused microwave oven – operating at atmospheric pressure, and a cavity microwave oven, which employs pressurized vessels) for crude oil, lubricating oil, and diesel fuel are described. The determination of copper and mercury by potentiometric stripping analysis presents better detection limits than stripping voltammetric determinations for the digested sample analysis. Loss of mercury by volatilization was verified when samples were digested in the focused microwave oven. Otherwise, this oven presented some advantages for the other metals, as the improved detection limits due to the employment of higher sample mass for the digestion process. The use of a ultrasonic bath to promote the extraction of copper and lead from lubricating oils in the presence of 1:1 (v/v) HClconc and H2O2 (30% m/v) was efficient. Thirty minutes of ultrasonic exposure were necessary for quantitative exctraction of copper and lead. Anodic stripping voltammetry using gold CDtrodes was applied for metal determination in the extracted solutions. The detection limits of the proposed method for copper and lead were 23 and 67 ng g-1, respectively, under application of 120 seconds as deposition time. Anodic stripping voltammetry at a gold electrode was used for the determination of copper and lead in ethanol fuel, without any prior sample treatment. Detection limits of 120 and 235 ng L-1 for copper and lead, respectively, were attained applying 900 s as deposition time. Alternatively, the ethanol evaporation followed by re-suspension in deionised water allowed the metals determination by stripping analysis. All results obtained for sample decomposition methods were compared with the ones obtained by electrothermal atomic absorption spectrometric determinations. The method, which employs prior ethanol evaporation followed by re-suspension in deionised water, was applied for the determination of cations and anions by capillary electrophoresis in the hydrated ethanol fuel (automotive fuel). Na+, K+, Ca2+, Cl-, NO3-, and SO42- ions were found in the analyzed samples. The detection limits for these ions were situated between 0.06 and 0.18 mg L-1.
7

Avaliação da concentração de metais pesados (Zn, Cd, Pb e Cu) em água de chuva visando sua aplicação como fonte alternativa de água potável na cidade de Juiz de Fora/MG

Cerqueira, Marcos Rodrigues Facchini 02 March 2012 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-07-07T12:40:57Z No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 4104766 bytes, checksum: a30bb0a2c3edae3f0d744732482aa070 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-07-08T13:31:42Z (GMT) No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 4104766 bytes, checksum: a30bb0a2c3edae3f0d744732482aa070 (MD5) / Made available in DSpace on 2016-07-08T13:31:42Z (GMT). No. of bitstreams: 1 marcosrodriguesfacchinicerqueira.pdf: 4104766 bytes, checksum: a30bb0a2c3edae3f0d744732482aa070 (MD5) Previous issue date: 2012-03-02 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / FAPEMIG - Fundação de Amparo à Pesquisa do Estado de Minas Gerais / Muitas pessoas sofrem da falta crônica de água potável para necessidades pessoais e, nesse contexto, a água de chuva surge como uma possível fonte alternativa. Em cima disso, foi proposto um método simples e efetivo para a determinação de cobre(II), cádmio(II), zinco(II) e chumbo(II) em 64 amostras de água de chuva de Juiz de Fora/MG/Brasil utilizando a técnica de redissolução potenciométrica. Um potenciostato μ-AUTOLAB foi utilizado para a aquisição dos dados e a célula eletroquímica consistia de um eletrodo de trabalho de carbono vítreo modificado com filme de mercúrio, um eletrodo de Ag/AgCl(sat) como eletrodo de referência e um de eletrodo de platina como eletrodo auxiliar. Foi realizada uma avaliação do pH do meio variando de 0-3 para uma determinação simultânea de Cd, Pb e Cu e de 0-6 para a determinação de Zn. Um Planejamento Estrela 22 foi realizado para a otimização das condições eletroquímicas das determinações. Para as determinações de Cd, Pb e Cu foram estudados níveis entre -1,06 e -0,64 V para o potencial de deposição (Ed), com tempo de deposição (td) entre 239 s e 662 s. Para a determinação de Zn os níveis estudados para o Ed foram entre -1,70 V e -1,10 V, com td entre 239 s e 662 s. A condição ótima encontrada para o pH do meio foi de pH = 4 para a determinação de Zn e um pH = 0 para a determinação de Cd, Pb e Cu. De acordo com as superfícies de resposta obtidas, foi estipulado para a determinação de Zn um Ed = -1,40 V e um td = 300 s e para a determinação de Cd, Pb e Cu um Ed = -1,00 V e um td = 300 s. Foram construídas curvas analíticas para verificar a linearidade do método. Os limites de detecção e quantificação foram de 1,26 e 3,83 μg L-1 para Zn, 0,38 e 1,26 μg L-1 para Cd, 0,41 e 1,36 μg L-1 para Pb e 0,96 e 3,20 μg L-1 para Cu, respectivamente. O método mostrou valores de recuperação entre 86 e 113%. As amostras de água de chuva também foram analisadas por espectroscopia de absorção atômica em forno de grafite (GFAAS), como método de referência, demonstrando uma boa correlação entre os resultados. Foram encontrados valores entre 3,93 e 13,8 μg L-1 de Zn, 3,11 e 7,51 μg L-1 de Cu, enquanto que nenhuma concentração significativa foi observada para Pb e Cd. Conforme os valores estipulados na Portaria nº 2914, de 12 de dezembro de 2011, do Ministério da Saúde, a água de chuva da região de Juiz de Fora pode ser considerada como potável com relação os parâmetros avaliados. / Many people suffer from a chronicle lack of potable water for their personal needs and, in this context, the rainwater arises as a possible alternative source. Upon this, an effective and simple method to determine copper(II), cadmium(II), zinc(II) and lead(II) in 64 rainwater samples from Juiz de Fora/MG/Brazil, using potentiometric stripping analysis (PSA), is proposed. A μ-AUTOLAB potentiostat was used for data acquisition and the electrochemical cell consisted of a working glassy carbon electrode modified with a thin mercury film, an Ag/AgCl(sat) as reference electrode and a platinum as auxiliary electrode. The pH of the medium was evaluated in the range of 0-3 for the simultaneous determination of Cd, Pb and Cu, and in the range of 0-6 for Zn. A 22 Star Design was run to optimize the analytical conditions. For Cd, Pb and Cu determination the studied levels for deposition potential (Ed) were between -1.06 V and -0.64 V, with deposition time (td) between 239 s and 662 s. For Zn determination the studied levels for Ed were between -1.70 V and -1.10 V, with td between 239 s and 662 s. The optimum medium pH conditions found were of pH = 4 for Zn determination and pH = 0 for Cd, Pb and Cu determination. According to the obtained response surfaces it was stipulated for Zn determination a Ed = -1.40 V and a td = 300 s and for Cu, Pb and Cd determination a Ed = -1.00 V and a td = 300 s. Analytical curves were constructed to verify the method linearity. The detection and quantification limits were of 1.26 and 3.83 μg L-1 for Zn, 0.378 and 1.26 μg L-1 for Cd, 0.407 and 1.36 μg L-1 for Pb and 0.960 and 3.20 μg L-1 for Cu, respectively. The method showed recovery values between 86 and 113%. The rainwater samples were also analyzed by graphite furnace atomic absorption spectrometry (GFAAS), as reference method, showing a good correlation between the results. Values between 3.93 and 13.8 μg L-1 of Zn, 3.11 and 7.51 μg L-1 of Cu were found, while no significant concentrations of Pb and Cd were found. According to the stipulated values on Portaria nº 2914, of december 12 of 2011, from Ministério da Saúde, the Juiz de Fora region rainwater can be considered potable, with respect to the evaluated parameters.

Page generated in 0.126 seconds