1 |
Amniotic fluid and fetal bladder volume in the last trimester of pregnancy: relationship between volumes and gender.January 1997 (has links)
Leung Yee Fong, Vivian. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1997. / Includes bibliographical references (leaves 159-169). / Acknowledgments --- p.i / Legend for figures --- p.ii / Legend for tables --- p.v / List of abbreviations --- p.vii / Abstract --- p.viii / Chapter Ch 1 --- Introduction --- p.1 / Chapter 1.1 --- Embryology --- p.1 / Chapter 1.1.1 --- Embryology of amniotic cavity --- p.1 / Chapter 1.1.2 --- Embryology of kidney and bladder --- p.3 / Chapter Ch 2 --- Background: What is already known about amniotic fluid volume? --- p.7 / Chapter 2.1 --- Normal physiology --- p.7 / Chapter 2.1.1 --- The origin of amniotic fluid: Where does it come from? --- p.8 / Chapter 2.1.2 --- Where does the amniotic fluid go? How reabsorbed? --- p.14 / Chapter 2.1.3 --- How is amniotic fluid volume controlled? --- p.18 / Chapter 2.2 --- Abnormal physiology --- p.26 / Chapter 2.2.1 --- Too much liquor: polyhydramnios --- p.26 / Chapter 2.2.2 --- Too little liquor: oligohydramnios --- p.28 / Chapter 2.2.3 --- Diseases and gender differences that may be related to parity and amniotic fluid volume --- p.30 / Chapter 2.3 --- Techniques of measuring amniotic fluid volume --- p.32 / Chapter 2.3.1 --- History --- p.32 / Chapter 2.3.2 --- Current most popular technique: amniotic fluid index --- p.38 / Chapter 2.4 --- Summary of what is known and not yet known about amniotic fluid volume --- p.48 / Chapter Ch 3 --- Aims of this study --- p.49 / Chapter Ch4 --- Method --- p.50 / Chapter 4.1 --- Equipment --- p.50 / Chapter 4.2 --- Subject selection criteria --- p.50 / Chapter 4.2.1 --- Criteria --- p.50 / Chapter 4.2.2 --- Total number of subjects studied --- p.51 / Chapter 4.2.3 --- Total number of subjects selected fulfilling all criteria --- p.51 / Chapter 4.2.4 --- Subject preparation --- p.52 / Chapter 4.3 --- Technique --- p.53 / Chapter 4.3.1 --- "Standard measurement of BPD, AC, FL and EFW" --- p.53 / Chapter 4.3.2 --- Standard measurement of Doppler --- p.54 / Chapter 4.3.3 --- Amniotic fluid index --- p.55 / Chapter 4.3.4 --- Bladder volume --- p.59 / Chapter 4.3.5 --- Fetal renal pelvis --- p.61 / Chapter 4.3.6 --- Intra-observer error techniques and calculation --- p.63 / Chapter 4.4 --- Techniques used in analysis --- p.65 / Chapter Ch5 --- Results --- p.67 / Chapter 5.1 --- Fetal parameters --- p.68 / Chapter 5.1.1 --- Fetal biparietal diameter (BPD) --- p.68 / Chapter 5.1.2 --- Fetal abdominal circumference (AC) --- p.69 / Chapter 5.1.3 --- Fetal femur length (FL) --- p.70 / Chapter 5.1.4 --- Pulsatility index values of umbilical artery --- p.71 / Chapter 5.1.5 --- Birth weight (BW) --- p.74 / Chapter 5.1.6 --- Estimated fetal weight --- p.76 / Chapter 5.2 --- Amniotic fluid index --- p.79 / Chapter 5.2.1 --- Amniotic fluid index-overall --- p.79 / Chapter 5.2.2 --- Amniotic fluid index-male and female --- p.81 / Chapter 5.2.3 --- The ten segments of amniotic fluid index distribution --- p.83 / Chapter 5.2.4 --- Amniotic fluid index relationship to estimated fetal weight --- p.86 / Chapter 5.2.5 --- Amniotic fluid index with gravidity and parity --- p.89 / Chapter 5.2.6 --- Amniotic fluid index with estimated fetal weight of different parity (best fit line) for both male and female --- p.93 / Chapter 5.3 --- Fetal urinary bladder volume (BV) --- p.96 / Chapter 5.3.1 --- Bladder volume-overall --- p.96 / Chapter 5.3.2 --- Bladder volume-male and female --- p.97 / Chapter 5.3.3 --- Bladder volume with estimated fetal weight- overall --- p.100 / Chapter 5.3.4 --- Bladder volume with estimated fetal weight in both male and female --- p.101 / Chapter 5.3.5 --- Bladder volume with gravidity and parity --- p.103 / Chapter 5.3.6 --- Bladder volume with amniotic fluid index --- p.105 / Chapter 5.4 --- Anteroposterior diameter of the fetal renal pelvis --- p.106 / Chapter 5.5 --- Hydronephrosis index values --- p.107 / Chapter Ch 6 --- Discussion --- p.108 / Chapter 6.1 --- Review of the study --- p.108 / Chapter 6.2 --- Discussion on subject --- p.111 / Chapter 6.2.1 --- Gestational age chosen --- p.111 / Chapter 6.2.2 --- Subject preparation --- p.112 / Chapter 6.3 --- Discussion of method --- p.114 / Chapter 6.3.1 --- Equipment --- p.114 / Chapter 6.3.2 --- Technique --- p.117 / Chapter 6.4 --- Discussion on results --- p.128 / Chapter 6.4.1 --- Normality of population --- p.128 / Chapter 6.4.2 --- Low birth weight/ IUGR in Chinese and Caucasian --- p.129 / Chapter 6.4.3 --- Cut-off points to detect oligohydramnios and polyhydramnios --- p.132 / Chapter 6.4.4 --- Amniotic fluid index-relationship with fetal weight --- p.143 / Chapter 6.4.5 --- Amniotic fluid index-relationship to parity --- p.145 / Chapter 6.4.6 --- "Relationship between gender, estimated fetal weight and amniotic fluid index" --- p.147 / Chapter 6.4.7 --- Parity and cut-off points for oligohydramnios and polyhydramnios --- p.150 / Chapter 6.4.8 --- Relationship of amniotic fluid volume to urinary function --- p.152 / Chapter Ch 7 --- Conclusions --- p.157 / References --- p.159
|
2 |
Interrelationships between stress, dietary intake, and plasma ascorbic acid during pregnancyMcFarland, Mary Ann January 1982 (has links)
The relationships between stress, ascorbic acid status, and the adequacy of nutrient intake during the third trimester of pregnancy were studied. Adequacy of nutrient and ascorbic acid intake were measured by diet histories and 24 hour recalls. Plasma ascorbic acid and cortisol levels were determined. Stress was assessed by Spielberger State-Trait Anxiety Inventories (STAI) and Symptom Checklists (SCL). Factors which may affect stress were assessed by a General Background Information Questionnaire.
All subjects had acceptable plasma ascorbic acid levels (0.48 - 1.64). A-State and A-Trait scores, X̄ = 1.55 and X̄ = 1.63 respectively, indicated the majority of subjects to be little stressed. There were positive significant correlations between age and cortisol, A-State and A-Trait measures of STAI, nutritional scores from diet histories and plasma cortisol. Significant negative correlations were obtained between month of pregnancy and plasma ascorbic acid levels, total ascorbic acid intake and A-State measurements of STAI, A-State measurements and income, A-State measurements and education, and A-State measurements and ascorbic intake as calculated from diet histories. There was no significant correlations between STAI, measurements and cortisol, plasma ascorbic acid and cortisol, and STAI measurements and plasma ascorbic acid. This study showed no conclusive evidence that ascorbic acid status or nutrient intake were affected by psychological stress. / Master of Science
|
3 |
Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm deliveryRolnik, Daniel Lorber 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks
|
4 |
Avaliação sequencial do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina -símile na predição do parto prematuro / Sequential evaluation of the cervix and test for phosphorylated insulin-like growth factor binding protein-1 in the prediction of preterm deliveryDaniel Lorber Rolnik 06 November 2013 (has links)
INTRODUÇÃO: O antecedente de parto prematuro espontâneo em gestação anterior é considerado o principal e mais importante fator de risco clínico para prematuridade, principal causa de morbidade e mortalidade neonatal. Cerca de 25% das pacientes que tiveram parto prematuro apresentarão recorrência. A prevenção secundária consiste na pesquisa de marcadores de maior risco, com o intuito de instituir medidas terapêuticas apropriadas e de evitar tratamentos desnecessários. A hipótese do presente estudo é a de que existe correlação entre os resultados da avaliação do colo uterino e do teste para proteína-1 fosforilada ligada ao fator de crescimento insulina-símile (phIGFBP-1) e que a utilização de ambos em associação possa predizer a ocorrência de parto prematuro com maior sensibilidade. OBJETIVOS: Averiguar a utilidade da medida do comprimento do colo uterino e do teste para phIGFBP-1 na predição do parto prematuro antes de 37 e de 34 semanas, a existência de relação dos testes entre si, o melhor valor de corte da medida do colo em diferentes idades gestacionais e a melhor época de realização de cada um dos exames. MÉTODO: Foram compilados e submetidos a análise secundária os dados de 101 gestantes com antecedente de parto prematuro atendidas no Setor de Baixo Peso Fetal da Clínica Obstétrica do Hospital das Clínicas da Faculdade de Medicina da Universidade de São Paulo, entre 2003 e 2008. A medida do comprimento cervical e o teste para phIGFBP-1 foram realizados a cada três semanas, entre 24 e 34 semanas de gestação, e comparados com o desfecho de parto prematuro e nascimento com 34 semanas ou menos, e o melhor valor de corte do colo uterino foi estabelecido por meio de curva de características operacionais. RESULTADOS: Das 101 gestações estudadas, 25 (24,8%) terminaram em parto prematuro, das quais 12 (11,9%) ocorreram com 34 semanas ou menos. As idades gestacionais médias de avaliação foram de 24, 27, 30 e 33 semanas, e os valores de corte do colo uterino foram de 22, 21, 20 e 16 mm, respectivamente. A medida do comprimento do colo apresentou maior sensibilidade (cerca de 70%) e foi capaz de predizer o parto prematuro em todas as avaliações. O teste para phIGFBP-1 não foi útil com 24 semanas, porém foi capaz de detectar de forma independente o risco de prematuridade com 27, com 30 e com 33 semanas. Houve associação estatística dos exames entre si, de forma que o comprimento cervical médio foi menor em gestantes com teste positivo para phIGFBP-1. A associação dos exames elevou a sensibilidade e o valor preditivo negativo de forma significativa. CONCLUSÕES: A medida do comprimento do colo pela ultrassonografia transvaginal constitui bom marcador de risco para parto prematuro com 24 semanas, e o teste para phIGFBP-1 é útil após 27 semanas. A associação dos dois exames possui alta sensibilidade e alto valor preditivo negativo em gestantes de alto risco para prematuridade espontânea, e a realização do primeiro com 24 semanas e do segundo com 27 semanas constitui bom modelo preditivo para o parto prematuro / INTRODUCTION: The history of spontaneous preterm birth in a previous pregnancy is considered the main and most important clinical risk factor for preterm birth, the leading cause of neonatal morbidity and mortality. About 25% of these patients will deliver prematurely again. Secondary prevention consists in the search for markers of increased risk, in order to institute appropriate therapeutic actions and to avoid unnecessary treatments. The hypothesis of this study is that there is a correlation between the results of the evaluation of the cervix and the test for phosphorylated insulin-like growth factor binding protein-1 (phIGFBP-1) and that the use of both in combination can predict the occurrence of preterm delivery with higher sensitivity. OBJECTIVES: To investigate the usefulness of the measurement of the cervical length and phIGFBP-1 rapid test in the prediction of preterm birth before 37 and 34 weeks, the existence of a relationship between the tests themselves, the best cutoff value of cervical length measurement at different gestational ages and the best time to carry out each of the exams. METHODS: Data of 101 women with previous preterm birth assisted at the Obstetrical Clinic of the Hospital das Clínicas, Faculty of Medicine, University of São Paulo between 2003 and 2008 were collected and subjected to secondary analysis. The measurement of cervical length and the phIGFBP-1 test were performed every three weeks, between 24 and 34 weeks gestation, and compared with the outcome of premature birth before 37 and 34 weeks, and the best cutoff value of the cervix was determined by receiver operator characteristic curves. RESULTS: Of the 101 pregnancies studied, 25 (24.8%) ended in preterm birth, of which 12 (11.9%) occurred at 34 weeks or less. The mean gestational age in each evaluation was 24, 27, 30 and 33 weeks, and the cutoff of the cervix were 22, 21, 20 and 16 millimeters, respectively. The measurement of cervical length showed the highest sensitivity (approximately 70%) and was able to predict preterm birth in all evaluations. The phIGFBP-1 test was not useful at 24 weeks, but was able to independently detect the risk of prematurity at 27, 30 and 33 weeks. Statistical association between the exams was observed, so that the mean cervical length was lower in pregnant women testing positive for phIGFBP-1. The combination of both tests significantly increased the sensitivity and negative predictive value. CONCLUSIONS: The measurement of cervical length by transvaginal ultrasound is a good marker of risk for preterm delivery at 24 weeks, and the test for phIGFBP-1 is useful after 27 weeks. The association of the two tests is valuable and shows high sensitivity and high negative predictive value in women at high risk for spontaneous preterm birth, when the first is preformed with 24 weeks, and the second with 27 weeks
|
Page generated in 0.1022 seconds