• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 59
  • 1
  • Tagged with
  • 60
  • 60
  • 39
  • 24
  • 18
  • 17
  • 11
  • 10
  • 9
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

"Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica" / DEVELOPMENT OF A CERAMIC MATERIAL TO COVER WALLS TO BE APPLIED IN DIAGNOSTIC RADIOLOGICAL PROTECTION

Frimaio, Audrew 12 April 2006 (has links)
Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas. / This study aims to formulate a ceramic composition for wall coating seeking to contribute to the optimization of diagnosis rooms’ shielding. The work was based on experimental measures of X-radiation attenuation (80 and 100 kV) using ceramic coating materials containing different ceramic bases (red, white, grês, stoneware porcelain tiles, etc). Among the appraised ceramic bases, the white grês presented better attenuation properties and it was considered the most suitable material for the targets of this work. Different formulations of white grês were studied and altered in order to obtain better attenuation properties. Simulations of ceramic compositions using grês coating were made maintaining the percentages of 12-20% clay; 6-18% kaolin; 12-25% phyllite; 8-14% quartz; 10- 18% feldspar; 32-40% pegmatite and 6-8% talc in the composition of the necessary raw-material. The quantitative and qualitative chemical compositions of these materials were also evaluated and the most common representative elements are SiO2, Fe2O3, Al2O3, CaO and Ti2O3. Formulations containing Pb and Ba oxides were studied, considering that CaO can be replaced by PbO or BaO. The attenuation properties for X-radiation were investigated by computer simulations considering the incident and transmitted X-ray spectra for the different studied compositions and they were compared to the properties of the reference materials Pb, Ba and BaSO4 (barite). The results obtained with the simulations indicated the formulated composition of grês ceramic base that presented better attenuation properties considering the X-ray energies used in diagnosis (80, 100 and 150 kV). Ceramic plates based on the formulated compositions that presented lower percentage differences related to Pb were experimentally produced and physically tested as wall coating and protecting barrier. Properties as flexion resistance module, density, load rupture, water absorption and Xradiation attenuation were evaluated for all produced plates.
22

"Desenvolvimento de um material cerâmico para utilização em proteção radiológica diagnóstica" / DEVELOPMENT OF A CERAMIC MATERIAL TO COVER WALLS TO BE APPLIED IN DIAGNOSTIC RADIOLOGICAL PROTECTION

Audrew Frimaio 12 April 2006 (has links)
Este estudo tem por objetivo formular um composto cerâmico para revestimento de paredes visando contribuir para a otimização da blindagem de salas de diagnóstico. O trabalho foi baseado em medidas experimentais de atenuação da radiação X (80 e 100 kV) empregando materiais cerâmicos de revestimento contendo diferentes suportes cerâmicos (vermelho, branco, grês, porcelanatos, etc). Dentre os suportes cerâmicos avaliados, o grês branco apresentou melhores propriedades atenuadoras, e foi considerado o mais adequado para a proposta deste trabalho. Diferentes formulações de grês branco foram estudadas e alteradas a fim de obter melhores propriedades atenuadoras. Foram efetuadas simulações de composições cerâmicas de revestimento grês dentro das porcentagens de matérias-primas necessárias na composição que são 12-20% argila; 6-18% caulim; 12-25% filito; 8-14% quartzo; 10-18% feldspato; 32- 40% pegmatito; 6-8% talco. As composições químicas quantitativas e qualitativas destes materiais foram também avaliadas, e os elementos constituintes mais comuns são SiO2, Fe2O3, Al2O3, CaO e Ti2O3. Considerando que o CaO pode ser substituído pelo PbO ou BaO, foram estudadas formulações com maiores teores de óxidos de Pb e Ba. O comportamento destes materiais como atenuadores para a radiação X foi investigado por meio de simulações computacionais que levaram em consideração os espectros de raios X incidentes e transmitidos através das diferentes composições estudadas e comparado com os materiais de referência Pb, Ba e BaSO4 (barita). Os resultados obtidos nas simulações indicaram as formulações do composto de suporte cerâmico grês que demonstram melhores propriedades de atenuação levando-se em conta as energias usadas em raios X diagnóstico (80, 100 e 150 kV). Placas cerâmicas baseadas na composição formulada que apresentou menor diferença percentual em relação ao Pb foram produzidas em laboratório e testadas fisicamente como revestimento de parede e barreira protetora. Propriedades como módulo de resistência à flexão, densidade, carga de ruptura, absorção de água e atenuação da radiação X foram avaliadas para todas as placas produzidas. / This study aims to formulate a ceramic composition for wall coating seeking to contribute to the optimization of diagnosis rooms’ shielding. The work was based on experimental measures of X-radiation attenuation (80 and 100 kV) using ceramic coating materials containing different ceramic bases (red, white, grês, stoneware porcelain tiles, etc). Among the appraised ceramic bases, the white grês presented better attenuation properties and it was considered the most suitable material for the targets of this work. Different formulations of white grês were studied and altered in order to obtain better attenuation properties. Simulations of ceramic compositions using grês coating were made maintaining the percentages of 12-20% clay; 6-18% kaolin; 12-25% phyllite; 8-14% quartz; 10- 18% feldspar; 32-40% pegmatite and 6-8% talc in the composition of the necessary raw-material. The quantitative and qualitative chemical compositions of these materials were also evaluated and the most common representative elements are SiO2, Fe2O3, Al2O3, CaO and Ti2O3. Formulations containing Pb and Ba oxides were studied, considering that CaO can be replaced by PbO or BaO. The attenuation properties for X-radiation were investigated by computer simulations considering the incident and transmitted X-ray spectra for the different studied compositions and they were compared to the properties of the reference materials Pb, Ba and BaSO4 (barite). The results obtained with the simulations indicated the formulated composition of grês ceramic base that presented better attenuation properties considering the X-ray energies used in diagnosis (80, 100 and 150 kV). Ceramic plates based on the formulated compositions that presented lower percentage differences related to Pb were experimentally produced and physically tested as wall coating and protecting barrier. Properties as flexion resistance module, density, load rupture, water absorption and Xradiation attenuation were evaluated for all produced plates.
23

Avaliação da resposta de detectores termoluminescentes na dosimetria de feixes clínicos utilizando diferentes objetos simuladores / Response evaluation of thermoluminescent detectors in clinical beams dosimetry using different phantoms

Luciana Cardoso Matsushima 23 August 2010 (has links)
A radioterapia é uma das três principais modalidades de tratamento utilizadas no tratamento de doenças malignas, como o câncer; as duas outras são a quimioterapia e a radiocirurgia. Em contraste com outras especialidades médicas que necessitam principalmente de conhecimento clínico e da experiência de especialistas, a radioterapia, com o uso da radiação ionizante no tratamento do câncer, necessita de grandes investimentos em tecnologias modernas e do esforço colaborativo de diversos profissionais que contribuem para o sucesso do tratamento. Na área de dosimetria clínica, uma calibração eficiente e precisa do feixe de radiação garante o conhecimento da dose fornecida ao paciente, assegurando, portanto, o sucesso do tratamento radioterápico. Este trabalho tem por objetivo o estudo comparativo da resposta termoluminescente dos dosímetros de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN (6 mm de diâmetro e 0,8 mm de espessura) com a resposta dos dosímetros de fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti com 3,15 x 3,15 x 0,9 mm3) na dosimetria de feixes clínicos de fótons (6 e 15 MV) e elétrons (6 e 9 MeV) utilizando objetos simuladores de água sólida (RMI-457), água e PMMA. Foram obtidas as curvas de dose-resposta para a radiação gama do cobalto-60 (60Co) no ar e em condições de equilíbrio eletrônico (placa de PMMA), e para elétrons e fótons clínicos nas profundidades de dose máxima. Foi avaliada também a sensibilidade dos dosímetros termoluminescentes e determinada a reprodutibilidade da resposta e a eficiência intrínseca para os diferentes tipos de simuladores e energias de radiação estudadas. Os resultados obtidos indicam que a principal vantagem do dosímetro de CaSO4:Dy é a sua maior sensibilidade para as doses de radiação avaliadas para os feixes do 60Co, fótons e elétrons, representando, portanto, uma alternativa viável para a aplicação em dosimetria nos setores de radioterapia. / Radiotherapy is one of the three principal treatment modalities used in the treatment of malignant diseases such as cancer, the other two are chemotherapy and radiosurgery. In contrast to other medical specialties that rely mainly on the clinical knowledge and experience of medical specialists, radiotherapy, with its use of ionizing radiation in treatment of cancer, relies heavily on modern technology and the collaborative efforts of several professionals whose coordinated team approach greatly influences the outcome of the treatment. In the area of clinical dosimetry, an efficient and accurate calibration of the radiation beam ensures knowledge of the radiation dose delivered to the patient, allowing thus the success of radiotherapy. This study aims to compare the thermoluminescent response of calcium sulphate doped with dysprosium (CaSO4:Dy) dosimeters produced by IPEN (6 mm in diameter and 0,8 mm tick) with the response of lithium fluoride (3,15 x 3,15 x 0,9 mm3) doped with magnesium and titanium (LiF:Mg,Ti) in dosimetry of clinical photons (6 and 15 MV) and electrons beams (6 and 9 MeV) using solid water (RMI-457), water and PMMA phantoms. Initially, the dose-response curves were obtained for irradiation in cobalt-60 gamma radiation source in air (PMMA plates) and under electronic equilibrium conditions and for clinical electrons and photons beams at depth of maximum dose. The sensitivities of the thermoluminescent dosimeters were also evaluated and the values of their reproducibilities and intrinsic efficiency were determined for the response to differents types of phantoms and radiation energy. The obtained results indicate that the main advantage of CaSO4:Dy dosimeters is the enhanced sensitivity to radiation doses measured for 60Co, photons and electrons beams, thus representing a viable alternative for application in dosimetry in the radiotherapy area.
24

Avaliação de dosímetros termoluminescentes empregando objetos simuladores equivalentes à água para aplicação na dosimetria de feixes clínicos de elétrons / Evaluation of thermoluminescent dosimeters using water equivalent phantoms for application in clinical electrons beams dosimetry

Amanda Bravim 26 January 2011 (has links)
A dosimetria em Radioterapia prevê a calibração do feixe de radiação e a dosimetria de rotina para controle de qualidade, pois o seu principal objetivo é determinar, com maior precisão, a dose absorvida pelo tumor. Este trabalho tem como objetivo avaliar o comportamento de três dosímetros termoluminescentes na dosimetria de feixes clínicos de elétrons. O desempenho de detectores de sulfato de cálcio dopado com disprósio (CaSO4:Dy) produzidos pelo IPEN foi comparado com o de dois dosímetros comercialmente disponíveis pela Harshaw, ambos denominados TLD-100, porém com dimensões distintas. Os dosímetros foram caracterizados com a utilização de objetos simuladores de água, água sólida RMI-457 e PMMA em campos de radiação de elétrons de 4, 6, 9, 12 e 16 MeV. Também foram realizadas medidas em feixes de fótons de 6 e 15 MV (2 e 5 MeV) apenas para comparação de resultados. As curvas de dose-resposta foram obtidas para a radiação gama do 60Co no ar e em condições de equilíbrio eletrônico e para feixes clínicos de fótons e elétrons nas profundidades de máxima dose. A sensibilidade, a reprodutibilidade, a eficiência intrínseca e a dependência energética dos dosímetros termoluminescentes foram estudadas. O CaSO4:Dy apresentou comportamento semelhante ao dos TLD-100 com uma vantagem em relação à sensibilidade para os feixes e doses de radiação estudados. Sendo assim, o dosímetro produzido pelo IPEN pode ser considerado uma nova alternativa para a dosimetria nos departamentos de Radioterapia. / The dosimetry in Radiotherapy provides the calibration of the radiation beam as well as the quality control of the dose in the clinical routine. Its main objective is to determine with greater accuracy the dose absorbed by the tumor. This study aimed to evaluate the behavior of three thermoluminescent dosimeters for the clinical electron beam dosimetry. The performance of the calcium sulfate detector doped with dysprosium (CaSO4: Dy) produced by IPEN was compared with two dosimeters commercially available by Harshaw. Both are named TLD-100, however they differ in their dimensions. The dosimeters were evaluated using water, solid water (RMI-457) and PMMA phantoms in different exposure fields for 4, 6, 9, 12 and 16 MeV electron beam energies. It was also performed measurements in photon beams of 6 and 15 MV (2 and 5 MeV) only for comparison. The dose-response curves were obtained for the 60Co gamma radiation in air and under conditions of electronic equilibrium, both for clinical beam of photons and electrons in maximum dose depths. The sensitivity, reproducibility, intrinsic efficiency and energy dependence response of dosimeters were studied. The CaSO4: Dy showed the same behavior of TLD-100, demonstrating only an advantage in the sensitivity to the beams and radiation doses studied. Thus, the dosimeter produced by IPEN can be considered a new alternative for dosimetry in Radiotherapy departments.
25

Contribuição para otimização das doses individuais dos trabalhadores no processo de expedição do gerador de Tecnécio-99m / Contribution to optimization of individual doses of workers in shipment of generator technetium-99m

Lizandra Pereira de Souza Fonseca 21 December 2009 (has links)
O Instituto de Pesquisas Energéticas e Nucleares, IPEN, pesquisa e produz radiofármacos que são distribuídos para todo o Brasil. Atualmente o radiofármaco com a maior quantidade de embalados expedidos por ano e com a maior atividade total é o gerador de tecnécio-99m. Com o intuito de diminuir as doses individuais dos trabalhadores envolvidos na produção de radiofármacos foi realizado um estudo de otimização da proteção radiológica no processo de expedição do gerador de tecnécio-99m, utilizando as técnicas de análise de custo-benefício diferencial, análise de custo-benefício integral, análise de prioridade com atributos múltiplos e análise com critérios múltiplos excedentes. Com alterações na configuração do embalado para despacho do gerador e com a aquisição de uma esteira transportadora foi possível estabelecer 4 opções de proteção. Os atributos considerados foram o custo da proteção, a dose coletiva, a dose individual e o esforço físico realizado pelo trabalhador para movimentar o embalado na falta da esteira. Para verificar a robustez das soluções analíticas encontradas com as técnicas utilizadas na otimização foi realizado um estudo de sensibilidade e foi constatado que a opção 3 é mais robusta que a opção 1, que deixa de ser a solução analítica com um aumento de R$ 20.000,00 no custo da proteção. / The Instituto de Pesquisas Energéticas e Nucleares, IPEN, radiopharmaceuticals research and produce that are distributed throughout Brazil, currently the radiopharmaceutical with the largest number of packaged shipped per year and with the highest total activity is the 99m technetium generator. To reduce individual doses for workers involved in the production of radiopharmaceuticals was performed a study of radiological protection optimization in the shipment process of technetium generator, using the techniques: diferencial cost-benefit analysis, integral cost-benefit analysis, multi-attribute utility analysis and multi-criteria outranking analysis. With changes in the configuration of packed for generator dispatch and with the acquirement of a mat transporter it was possible establish 4 protection options. The attributes considered were the protection cost, collective dose, individual dose and physical effort by worker to move the package without the mat. To assess the robustness of analytical solutions found with the techniques used in the optimization we performed a sensitivity study and found that option 3 is more robust than option 1, which is no longer the analytical solution with an increase of R$ 20.000,00 the cost of protection.
26

Controle de dose em transporte rodoviário de material radioativo / Dose control in road transport of radioactive material

Gerulis, Eduardo 05 December 2013 (has links)
As doses de radiação ionizante para os trabalhadores no transporte de material radioativo devem ser tão pequenas quanto razoavelmente exequível. As doses médias dos motoristas e carregadores amostrados neste trabalho devem ser diminuídas. A demonstração do controle das doses em veículo rodoviário com material radioativo, requisitada pelo regulamento brasileiro atual, norma CNEN NE 5.01, é apresentada em formulário próprio com valores de exposição obtidos em posições de ocupação regular de indivíduos do público e de trabalhadores, mesmo quando se expede veículo sem a necessidade de uso exclusivo (∑ IT 50). Este trabalho mostra, por meio de pesquisa bibliográfica, elaboração de modelos e pesquisa de campo, que esta demonstração do controle com a obtenção dos valores de exposição nesta situação, para um método de controle melhor, deve ser realizada pela apresentação do registro do acúmulo de cargas, limitado (∑ IT 50), a fim de evitar a obtenção destas medidas, para que haja padronização com regulamentos estrangeiros e para que os custos e os tempos, importantes para expedição de radiofármacos com meia-vida curta, e também as atuais doses laborais dos técnicos de radioproteção sejam todos diminuídos. Os valores de exposição dos parâmetros utilizados com esse método são menores do que seus limites regulamentares. Para contribuir com essas finalidades devem ser apresentadas pelo regulamento brasileiro atualizado as distâncias de segregação entre as cargas e as cabines dos veículos. / The radiation doses to workers in the transport of radioactive material should be as low as reasonably achievable. The average doses of drivers and loaders, sampled in this thesis should be decreased. The demonstration of doses control in a road vehicle with radioactive material required by the current Brazilian regulation, CNEN NE 5.01 should be written in its own printed form with exposure values obtained in normally occupied positions from workers and members of the public, even when the consignment does not need \"exclusive use\" (∑ IT 50). Through bibliographic research, modeling and field research, this research work shows that this demonstration of the control should be done by writing the registration accumulation of load, limited (∑ IT 50), also in the own printed form. It is for a better control method, in order to avoid the use of measuring equipment, to build standardization with foreign regulations, to the current occupational doses of radioprotection technicians, the costs and time, (important for consignment with radiopharmaceuticals short half-life) would be all smaller. Exposure values of the parameters used with this method are smaller than regulatory limits. The segregation distances between loads and the cabins of vehicles shall be showed by Brazilian regulation updated to contribute to these aims.
27

Avaliação das doses resultantes de procedimentos radiodiagnósticos realizados em medicina veterinária e avaliação das doses secundárias de radiação espalhada no corpo clínico e nos proprietários dos animais / Evaluation of doses from radiodiagnotic procedures performed in veterinary medicine and assessing of the doses of secondary radiation in the medical staff and animal owners

Veneziani, Glauco Rogério 25 March 2013 (has links)
O objetivo primordial em radiologia veterinária é a produção de radiografias com qualidade diagnóstica, em uma primeira tentativa. Esse objetivo deve atender a três propósitos: (1) diminuir a exposição à radiação do paciente e trabalhadores; (2) diminuir o custo do estudo para o cliente e (3) produzir dados diagnósticos para rápida interpretação e tratamento do paciente. Esse trabalho teve por objetivo a determinação das doses em cães submetidos a radiografias de tórax e abdômen utilizando a técnica da dosimetria termoluminescente (TL). As doses de radiação foram avaliadas com a utilização de dosímetros termoluminescentes de sulfato de cálcio dopado com disprósio (CaSO4:Dy) e fluoreto de lítio dopado com magnésio e titânio (LiF:Mg,Ti). Os resultados obtidos indicam que é extremamente importante a avaliação das doses de radiação envolvidas em procedimentos diagnósticos de radiologia veterinária, para a avaliação das doses nos animais e para ser usado como um parâmetro para a monitoração individual dos proprietários de animais, que auxiliam no posicionamento, e para a proteção dos trabalhadores ocupacionalmente expostos nas Clínicas de Radiologia Veterinária. / The primary goal in veterinary radiography is to produce radiographs of diagnostic quality on the first attempt. This goal serves three purposes: (1) to decrease radiation exposure to the patient and veterinary personnel; (2) to decrease the cost of the study for the client; and (3) to produce diagnostic data for rapid interpretation and treatment of the patient. This work aimed to determine the doses in dogs submitted to chest and abdomen Xrays using the technique of thermoluminescence (TL) dosimetry. The radiation doses were assessed using thermoluminescent dosimeters of calcium sulphate doped with dysprosium (CaSO4:Dy) and lithium fluoride doped with magnesium and titanium (LiF:Mg,Ti). The obtained results indicate that is extremely important the assessment of radiation doses involved in veterinary diagnostic radiology procedures, to evaluate the delivered doses to the animals, to be used as a parameter in the individual monitoring of pets owners, who assist the animal positioning, and to protect occupationally exposed workers at the Veterinary Radiology Clinics.
28

Medidor não invasivo de alta tensão, tempo e exposição em aparelhos de raios x

Laan, Flavio Tadeu van der January 1996 (has links)
Neste trabalho, propõe-se desenvolver um medidor para controle de qualidade em RX diagnóstico, que permite medidas rápidas de alta tensão, tempo e exposição em aparelhos de RX, de modo não invasivo, baseado na leitura frontal do feixe. A unidade é composta de dois diodos fotovoltaicos como transdutores, amplificadores de corrente, como condicionadores de sinais e de um sistema de aquisição e processamento, para o tratamento do sinal digital. 0 medidor permite a medida da alta tensão de pico (kVp), taxa de exposição (R/min), e do tempo de exposição (s) em aparelhos de RX, na faixa de 50 a 150 kVp. As medidas são realizadas num sistema microprocessado, programadas por teclado e apresentadas num display alfanumérico. São memorizadas e transferidas a um microcomputador por meio de uma saída serial / This work contains a development of an instrument for non invasive as well fast measurement of essential parameters related to quality control of X-ray equipment's using only the frontal reading of the beam intensity. The unit is composed of a data acquisition system for reading two Photovoltaic diodes sensor, for measurement of Peak Kilovoltage (kVp), Exposure Rate (R/min) and Exposure Time (s) of the x-ray equipment. The measurements are performed with microprocessed instrumentation, with programmed keyboard ability, alphanumeric display, memory data storage and serial output to microcomputer connection.
29

Medidor não invasivo de alta tensão, tempo e exposição em aparelhos de raios x

Laan, Flavio Tadeu van der January 1996 (has links)
Neste trabalho, propõe-se desenvolver um medidor para controle de qualidade em RX diagnóstico, que permite medidas rápidas de alta tensão, tempo e exposição em aparelhos de RX, de modo não invasivo, baseado na leitura frontal do feixe. A unidade é composta de dois diodos fotovoltaicos como transdutores, amplificadores de corrente, como condicionadores de sinais e de um sistema de aquisição e processamento, para o tratamento do sinal digital. 0 medidor permite a medida da alta tensão de pico (kVp), taxa de exposição (R/min), e do tempo de exposição (s) em aparelhos de RX, na faixa de 50 a 150 kVp. As medidas são realizadas num sistema microprocessado, programadas por teclado e apresentadas num display alfanumérico. São memorizadas e transferidas a um microcomputador por meio de uma saída serial / This work contains a development of an instrument for non invasive as well fast measurement of essential parameters related to quality control of X-ray equipment's using only the frontal reading of the beam intensity. The unit is composed of a data acquisition system for reading two Photovoltaic diodes sensor, for measurement of Peak Kilovoltage (kVp), Exposure Rate (R/min) and Exposure Time (s) of the x-ray equipment. The measurements are performed with microprocessed instrumentation, with programmed keyboard ability, alphanumeric display, memory data storage and serial output to microcomputer connection.
30

Medidor não invasivo de alta tensão, tempo e exposição em aparelhos de raios x

Laan, Flavio Tadeu van der January 1996 (has links)
Neste trabalho, propõe-se desenvolver um medidor para controle de qualidade em RX diagnóstico, que permite medidas rápidas de alta tensão, tempo e exposição em aparelhos de RX, de modo não invasivo, baseado na leitura frontal do feixe. A unidade é composta de dois diodos fotovoltaicos como transdutores, amplificadores de corrente, como condicionadores de sinais e de um sistema de aquisição e processamento, para o tratamento do sinal digital. 0 medidor permite a medida da alta tensão de pico (kVp), taxa de exposição (R/min), e do tempo de exposição (s) em aparelhos de RX, na faixa de 50 a 150 kVp. As medidas são realizadas num sistema microprocessado, programadas por teclado e apresentadas num display alfanumérico. São memorizadas e transferidas a um microcomputador por meio de uma saída serial / This work contains a development of an instrument for non invasive as well fast measurement of essential parameters related to quality control of X-ray equipment's using only the frontal reading of the beam intensity. The unit is composed of a data acquisition system for reading two Photovoltaic diodes sensor, for measurement of Peak Kilovoltage (kVp), Exposure Rate (R/min) and Exposure Time (s) of the x-ray equipment. The measurements are performed with microprocessed instrumentation, with programmed keyboard ability, alphanumeric display, memory data storage and serial output to microcomputer connection.

Page generated in 0.0923 seconds