PROPRIEDADES DE ATENUAÇÃO DE NANOCOMPÓSITOS PARA USO EM PROTEÇÃO RADIOLÓGICABotelho, Marcel Zago 30 March 2009 (has links)
Made available in DSpace on 2018-06-27T18:56:32Z (GMT). No. of bitstreams: 2
Marcel Zago Botelho.pdf: 6878925 bytes, checksum: 22ad774a47cc0769a99676eb64ea10fe (MD5)
Marcel Zago Botelho.pdf.jpg: 3401 bytes, checksum: 2e13d66eded5ce0245644489e795b21f (MD5)
Previous issue date: 2009-03-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The aim of this study is to evaluate the attenuation properties of the nanocomposites in the
energy range between 20 and 120 keV. In order to evaluate the efficiency of nanostructured
materials in the attenuation of radiation the results will be compared to data obtained with the same
material in the non-nanostructured form. The nanostructured materials are characterized by having a
size of crystallites less than 100nm, and shows different properties with respect to conventional
materials. The nanocomposites used in this study were produced through the aggregation of
nanoparticles of copper oxide (CuO) and zinc oxide (ZnO) to beeswax. The concentration of
nanoparticles in the composite was varied between 5% and 10%. For comparison purpose the
copper oxide and zinc oxide in a non-aggregated nanoparticles were also agregated in a nonnanoparticulated
form to beeswax in the same proportion as for nanostructured materials. Samples
were produced with dimensions 10 cm x 10 cm and 2 mm in thicknesses. The attenuation properties
of the samples produced were evaluated at high energy X-ray beams, emmited by a X-ray
equipment used in conventional radiology, and the low energy x-ray beams are produced by a
clinical mammography equipment. The air kerma values, for different material thicknesses, were
measured with an ionization chamber for x-ray beam produced at 60 kV and 102 kV. Results shows
that the attenuation provided by the copper oxide is slighly higher for the nanoestrured materials
compared with for the non-nanoestrutured ones. In the case of the zinc oxide, the material in the
non-nanometric form shows an increasing of the attenuation relative to the nanoparticulates ones.
In the mammography energy range the study was carried out for beams generated at 22, 26 and 30
kV. It is observed that the copper oxide in nanometric structure attenuate at about 23% more
radiation than the same material in the non-nanoparticulate form. In the case of the zinc oxide the
attenuation is higher at about 7% for the material in the non-nanometric form. This study suggest
that nanostructured materials show great potential for application in radiological protection, because
it can be easily incorporated into different compounds allowing the development of new materials
for use in radiological protection. / Este estudo tem por objetivo determinar as propriedades de atenuação de nanocompósitos na
faixa de energia entre 20 e 120 keV. Com o propósito de avaliar a eficiência dos materiais
nanoestruturados na atenuação da radiação os resultados obtidos serão comparados aos dados
obtidos com o mesmo material na forma não-nanoestruturada. Os materiais nanoestruturados são
caracterizados por terem um tamanho de cristalito inferior a 100nm e apresentar propriedades
diferenciadas em relação aos materiais convencionais. Os nanocompósitos utilizados neste trabalho
foram obtidos a partir da agregação de nanopartículas de óxido de cobre (CuO) e óxido de zinco
(ZnO) a cera de abelha alvejada. A concentração de nanopartículas nos compostos foi variada entre
5% e 10%. Para fins de comparação, o óxido de cobre e o óxido de zinco, na forma nãonanoparticulada
também foram agregados na mesma proporção que os materiais nanoestruturados a
cera de abelha alvejada. Foram produzidas amostras com dimensões 10 cm x 10 cm e 2 mm de
espessura. As propriedades de atenuação destas amostras foram avaliadas em feixes de raios X
produzidos por um equipamento de radiologia convencional, e por um equipamento clínico de
mamografia. Na região de radiologia convencional foram realizadas medições de kerma no ar para
diferentes espessuras de material para feixes de raios X gerados nas tensões de 60 e 102 kV. Os
resultados obtidos mostraram uma leve tendência de maior atenuação da radiação pelo o óxido de
cobre na forma nanométrica que o óxido de cobre na forma não-nanométrica. Observou-se uma
tendência de maior atenuação pelo óxido de zinco na forma não-nanoparticulada. A atenuação da
radiação para feixes de mamografia foi avaliada nas tensões de 22, 26 e 30 kV. Os dados obtidos
mostraram que para o óxido de cobre na forma nanométrica a atenuação da radiação é maior em até
23% com relação às estruturas na forma não-nanométrica. Para o óxido de zinco a atenuação para o
material não-nanométrico foi superior em até 7% relativo às estruturas na forma nanométrica. Os
resultados obtidos neste trabalho sugerem que os materiais nanoestruturados mostram um grande
potencial para aplicação em proteção radiológica, pois podem ser facilmente incorporados a
diferentes compostos possibilitando o desenvolvimento de novos materiais.
|
42 |
Aspectos radiológicos e dose de radiação em mamografia de mulheres com implantes mamários / Radiological aspects and radiation dose in augmentation mammographyCouto, Lilian Soares 23 February 2017 (has links)
Submitted by Cássia Santos (cassia.bcufg@gmail.com) on 2017-03-06T13:16:04Z
No. of bitstreams: 2
Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-03-06T14:55:49Z (GMT) No. of bitstreams: 2
Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-03-06T14:55:49Z (GMT). No. of bitstreams: 2
Dissertação - Lilian Soares Couto - 2017.pdf: 4439690 bytes, checksum: 714aa1514cdb6d691695bec489132c48 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2017-02-23 / The main test for early detection of breast cancer is mammography. In the last decade, there was a significant increase in the number of women undergoing mammography for screening of breast cancer and have breast implants. Despite the mammographic screening recommended for patients with implants, follow the same range as recommended for patients doesn’t have implants, routinely includes images with posterior displacement of the implant (ID), known as Eklund’s maneuver, adding four views in relation to who do not have it. This study aimed to evaluate the mammographic characteristics of the required views and the dose that these patients have received in the examination. Data collection was divided into two stages: the first, for radiological evaluation of images and the second for data collection of radiographic techniques for image production. The radiological evaluation was performed by radiologists, with experience in mammography reading, who independently answered a questionnaire about: 1) implant position, 2) overall improvement image, 3) amount of breast tissue seen in the maneuver in relation to the standard images, 4) if there were findings in the exams, e) which view these findings were seen. For the data of the mammographic techniques, from the records in the DICOM (Digital Imaging and Communications in Medicine) heading of each image were collected: voltage (kV) and current x time (mAs) emitted by the device, target/filter combination, breast thickness and mean glandular dose (DGM). The data were analyzed by means of statistical treatment. Regarding the radiological evaluation, the evaluators agreed that the amount of breast tissue in the in the ID views depends on the position of the implant and is smaller in the retroglandular position. There was a significant increase in the quality of the images with the displacement of the implant and there were no findings seen in the exams, which were not seen in those views. Regarding the radiation doses received by patients with implants, during the mammographic examination, the DGM exceeds the limit recommended by the agencies responsible for the protocols. This study suggests the need for continuity of the research, with an increase in the sample and optimization of the mammographic technique, in order to evaluate the risk benefit ratio of maintaining all views of augmentation mammograms. / O principal exame para detecção precoce do câncer de mama é a mamografia. Na última década, houve um crescimento expressivo do número de mulheres que realizam mamografia para o rastreamento do câncer de mama e possuem implantes mamários. Apesar do rastreamento mamográfico recomendado para as pacientes com implantes, seguir o mesmo intervalo que o preconizado para as pacientes que não possuem, inclui de rotina, imagens com deslocamento posterior do implante, conhecida como manobra de Eklund, adicionando-se quatro incidências em relação às que não possuem. Este trabalho propôs-se à avaliação das características mamográficas das incidências exigidas e da dose de radiação que estas pacientes têm recebido no exame. A coleta de dados foi dividida em duas etapas: a primeira, para avaliação radiológica das imagens e a segunda para levantamento dos dados das técnicas radiográficas para produção das imagens. A avaliação radiológica foi realizada por médicos radiologistas, com experiência em leitura de mamografias, que responderam de forma independente um questionário sobre: 1) posição do implante, 2) melhoria global em detalhe de imagem, 3) quantidade de tecido mamário visto na manobra de Eklund em relação as imagens padrões, 4) se houve alteração nos exames, e) em quais incidências estas alterações foram vistas. Para os dados das técnicas mamográficas, foram coletados, a partir dos registros no cabeçalho DICOM (Digital Imaging and Communications in Medicine) de cada imagem: tensão (kV) e corrente x tempo (mAs), combinação alvo/filtro, espessura da mama e dose glandular média (DGM). Os dados foram analisados por meio de tratamento estatístico. Em relação à avaliação radiológica, os avaliadores concordaram que a quantidade de tecido mamário nas imagens com deslocamento do implante, depende da posição em que o implante se encontra, sendo menor na posição retroglandular. Houve significativo aumento da qualidade das imagens com o deslocamento do implante e não houve nenhuma alteração vista nos exames, que não tenham sido visibilizadas nas imagens com a manobra. Quanto às doses de radiação recebidas pelas pacientes com implantes, durante o exame mamográfico, a DGM excede o limite preconizado pelas agências responsáveis pelos protocolos. Este estudo sugere a necessidade de continuidade da pesquisa, com incremento da amostra e otimização da técnica mamográfica, para que se possa avaliar, a relação benefício risco de se manter todas as incidências em mamografias de mulheres com implantes mamários.
|
43 |
Caracterização de um dispositivo de ensaio para determinação da camada semiredutora e da filtração com equivalência de qualidade de acordo com a norma ABNT NBR IEC 60601-1-3 / Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3Vlamir Viana 28 June 2012 (has links)
A motivação deste trabalho foi o desenvolvimento e validação de um dispositivo para realizar os testes estabelecidos na ABNT NBR IEC 60601-1-3 nas versões publicadas de 2001[1] e 2011[2]. A finalidade dos ensaios é determinar a camada semirredutora - CSR (Half Value Layer - HVL) e a filtração com equivalência de qualidade, em mmAl, dos materiais que interceptam o feixe de raios X desde a sua emissão até o dispositivo receptor de imagem de raios X. Esta filtração inclui os materiais presentes no conjunto fonte de radiação X, formado pela cúpula de proteção radiológica com o tubo de raios X inserido, pelo sistema de colimação (filtração inerente) e pelos materiais presentes nos suportes de pacientes, como mesa e bucky mural sendo que ambos incorporam dispositivo receptor de imagem que também é avaliado. No desenvolvimento foi levada em consideração a rotina da execução do ensaio, com a finalidade de diminuir ao máximo a interação do operador com o sistema, a fim de reduzir o fator humano na execução, refletindo diretamente na incerteza de medição, na diminuição do tempo de execução e na segurança radiológica. O dispositivo desenvolvido foi validado com relação aos seguintes aspectos: a) Influência do dispositivo trocador de filtros quanto ao posicionamento e distribuição dos filtros; b) Influência da pureza dos filtros de alumínio utilizados no dispositivo, e a c) Comparação entre os ensaios realizados com dispositivo de ensaio desenvolvido com relação aos ensaios realizados com um gerador de raios X de referência. / The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 [1] and 2011 [2]. The purpose of the tests is to determine the half-value layer HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator.
|
44 |
Caracterização de um dispositivo de ensaio para determinação da camada semiredutora e da filtração com equivalência de qualidade de acordo com a norma ABNT NBR IEC 60601-1-3 / Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3Viana, Vlamir 28 June 2012 (has links)
A motivação deste trabalho foi o desenvolvimento e validação de um dispositivo para realizar os testes estabelecidos na ABNT NBR IEC 60601-1-3 nas versões publicadas de 2001[1] e 2011[2]. A finalidade dos ensaios é determinar a camada semirredutora - CSR (Half Value Layer - HVL) e a filtração com equivalência de qualidade, em mmAl, dos materiais que interceptam o feixe de raios X desde a sua emissão até o dispositivo receptor de imagem de raios X. Esta filtração inclui os materiais presentes no conjunto fonte de radiação X, formado pela cúpula de proteção radiológica com o tubo de raios X inserido, pelo sistema de colimação (filtração inerente) e pelos materiais presentes nos suportes de pacientes, como mesa e bucky mural sendo que ambos incorporam dispositivo receptor de imagem que também é avaliado. No desenvolvimento foi levada em consideração a rotina da execução do ensaio, com a finalidade de diminuir ao máximo a interação do operador com o sistema, a fim de reduzir o fator humano na execução, refletindo diretamente na incerteza de medição, na diminuição do tempo de execução e na segurança radiológica. O dispositivo desenvolvido foi validado com relação aos seguintes aspectos: a) Influência do dispositivo trocador de filtros quanto ao posicionamento e distribuição dos filtros; b) Influência da pureza dos filtros de alumínio utilizados no dispositivo, e a c) Comparação entre os ensaios realizados com dispositivo de ensaio desenvolvido com relação aos ensaios realizados com um gerador de raios X de referência. / The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 [1] and 2011 [2]. The purpose of the tests is to determine the half-value layer HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator.
|
45 |
Informatização e unificação dos programas de proteção radiológica: monitoramento das radiações ionizantes e sua otimização / Web-based system to unify the radiological protection programs: ionizing radiation monitoring and optimizationLevy, Denise Sahyun 25 August 2015 (has links)
Um programa de monitoramento para fins de proteção radiológica deve mostrar como ele auxilia na obtenção e demonstração de um grau de proteção adequado e comprovar que as condições de trabalho continuam satisfatórias com o transcorrer do tempo. Para o controle operacional das exposições à radiação ionizante em qualquer local de trabalho, a Comissão Internacional de Proteção Radiológica (CIPR) recomenda um programa de proteção radiológica operacional, proporcional ao grau de risco, para garantir o gerenciamento efetivo das medidas necessárias para se satisfazer o principio da otimização. O presente trabalho de pesquisa tem como premissa o potencial das Tecnologias da Informação e Comunicação (TIC) como ferramenta para a comunicação e disseminação do conhecimento em Proteção Radiológica. O trabalho inclui a informatização da filosofia e técnica do monitoramento e sua otimização, unificando e inter-relacionando informações advindas de diversas publicações nacionais e internacionais, oferecendo às instalações radiativas brasileiras um veículo completo para informação e pesquisa, que permite dimensionar os esforços de otimização tornando-os eficazes e justificados. O sistema oferece ainda tópicos de discussões no intuito de ampliar o repertório dos profissionais do campo da proteção radiológica, suscitando novas reflexões a favor da segurança. Trata-se dos temas desenvolvidos nesta tese, a saber: a necessidade de um monitoramento auditor e discussões mais aprofundadas sobre as exposições potenciais. As reflexões propostas na presente tese vêm ao encontro das novas exigências internacionais, propondo ações passíveis de serem incorporadas na prática laboral. Dentro dos princípios da proteção radiológica, a implementação de um programa de monitoramento auditor permite avaliar se os critérios e ações previamente estabelecidas pelo Serviço de Proteção Radiológica são ou não atendidos, se foram implementados com eficácia e se permanecem adequados. Os fatos resultantes dos procedimentos de auditoria auxiliam a detectar deficiências no processo, possibilitando conclusões e recomendações diante de possíveis fatores desencadeadores de exposições indevidas. Por meio de exames sistemáticos das atividades realizadas em cada tipo de monitoramento, a auditoria infere segurança ao processo, respaldando o trabalhador na realização do monitoramento relacionado com a tarefa e respaldando a instalação, que empreende ações responsáveis a favor da segurança. Em relação às exposições potenciais, somente duas publicações da CIPR são expressivas e desenvolvem o assunto. Entretanto, ainda que forneçam a fundamentação teórica, são incompletas em seus exemplos. Há uma grande falta de conhecimento das probabilidades de falhas, o que atualmente constitui um vasto campo de pesquisa da proteção radiológica. A presente tese propõe, a partir de árvores de falhas, caminhos que auxiliam a quantificar probabilisticamente a ocorrência das exposições potenciais e a probabilidade de se atingir um determinado valor da dose. Acreditamos que o potencial das TIC contribuirá largamente para a disseminação da informação para as instalações radiativas, estimulando o desenvolvimento neste país de grandes extensões territoriais, onde permanece um desafio oferecer o acesso à informação ao maior número de pessoas possível, minimizando custos e maximizando resultados. / A monitoring program for the purposes of radiological protection should demonstrate an adequate protection degree and prove that working conditions remain appropriate as time goes by. For operational control of exposures to ionizing radiation in any workplace, the International Comission on Radiation Protection (ICRP) recommends establishing a program of operational radiation protection, proportional to the risk, to ensure the effective management of all necessary measures to satisfy the principle of optimization. This research work focus on the potential value of Information and Communication Technologies (ICTs) to enhance communication and education on Radiological Protection throughout Brazil. The work includes the informatization of the monitoring policy and techniques, interrelating information currently scattered in several documents, providing Brazilian radioactive facilities a complete repository for research, consultation and information, which allows to size optimization efforts by technology, enabling them to be effective and justified. The content of monitoring programs involves not only the collection and interrelationship of existing information in the publications, but also new approaches from some recommendations, presenting some initiatives towards safety. In this sense, the two contents researched and expanded are: the need for an auditor monitoring and discussions on potential exposures. The recommendations proposed in this thesis meet the new international requirements stablished by the International Agency of Nuclear Energy (IAEA) and propose appropriate actions to be incorporated into labor practice. Respecting the scope of the principles of radiological protection, an auditing program permits to evaluate whether criteria and actions previously established by Radiological Protection Service are effectively implemented and remain appropriate as time goes by. The results of auditing procedures help to detect deficiencies in the process, enabling conclusions and recommendations, avoiding possible triggers of undue exposures. Through systematic examinations of activities in each type of monitoring, auditing attempt to ensure the process, supporting the employee in performing task-related monitoring and support the facility that choose responsible actions towards safety. Furthermore, regarding potential exposures, only two publications of ICRP develop expressively the issue. Even though these publications provide the fundamental theory, they are incomplete in their examples. There is still lack of knowledge of failure probabilities, which currently constitutes a broad research field in radiological protection. This research work proposes the development of fault trees, suggesting paths to quantify probabilistically the occurrence of potential exposures, as well as probabilities to reach a certain level of dose. We believe that the potential of ICT shall contribute greatly to provide information where it is needed, stimulating development in this large country where it is a strong challenge to ensure access to information to as many people as possible, minimizing costs and optimizing results.
|
46 |
Implantação de radiações de referência em máquina de raios X diagnóstico médico para fins de calibração de dosímetros pessoaisAnnibal Theotonio Baptista Neto 28 February 2005 (has links)
Nenhuma / Campos de raios-x que estejam em conformidade com os requisitos internacionais de padronização nem sempre são disponíveis em uma região e, principalmente, em países em desenvolvimento. Esta situação tem sido usada como justificativa para a ausência de calibração de dosímetros pessoais e tem contribuído para a falta de confiabilidade nos programas de monitoração de trabalhadores expostos à radiação. Considerando a existência de diversas máquinas de raios-x em hospitais e a necessidade da calibração de dosímetros pessoais, este trabalho investigou a viabilidade da implantação de feixes de radiação-x destinados à calibração, comparáveis às radiações padronizadas internacionalmente, em uma máquina de raios-x diagnóstico médico. A implantação das radiações para calibração foi realizada com a determinação e comparação de parâmetros dos feixes de raios-x como a tensão do tubo, camada semi-redutora, uniformidade do campo de radiação, filtração e radiação espalhada. Os procedimentos, a geometria e as condições de irradiação foram, sempre, os mais simples possíveis para uma confiabilidade mínima dos resultados, nas condições usuais em hospitais. A viabilidade do uso dos feixes de radiação implantados foi confirmado através da análise do desempenho de um dosímetro pessoal do tipo filme, em calibrações e irradiações no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear, no Laboratório Nacional de Metrologia das Radiações Ionizantes e no University of Wisconsin Radiation Calibration Laboratory. Apesar da diferença entre os feixes de raios-x implantados e as radiações de referência, o desempenho do dosímetro pessoal atendeu aos requisitos para a monitoração individual. / X-ray fields that comply with international standardization requirements are not available in a world region, mainly in developing countries. This is used as an excuse for a lack of calibration of personal dosimeters and, consequently, a lack of reliability in individual monitoring programs applied to occupational workers under radiation exposures. Considering the availability of x-ray machines in many hospitals, this work studied the feasibility of implementing x-ray calibration beams in a medical diagnostic machine, which are comparable to international reference radiations for calibrating personal dosimeters. Implementation of the calibration beams was carried out by determining and comparing beam parameters as tube voltage, half-value layer, beam uniformity, filtration and scattered radiation. Procedures, geometry and exposure conditions were as simple as possible for a minimum reliability and close to the hospital conditions. The feasibility of the use of the implemented radiation beams was confirmed by analyzing the performance of a film personal dosimeter under calibration and irradiation at the Dosimeter Calibration Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear, the National Metrology Laboratory for Ionizing Radiations and the University of Wisconsin Radiation Calibration Laboratory. In spite of the difference between the implemented x-ray beams and the reference radiations, the performance of the film personal dosimeter complied with the accuracy requirements for individual monitoring.
|
47 |
Informatização e unificação dos programas de proteção radiológica: monitoramento das radiações ionizantes e sua otimização / Web-based system to unify the radiological protection programs: ionizing radiation monitoring and optimizationDenise Sahyun Levy 25 August 2015 (has links)
Um programa de monitoramento para fins de proteção radiológica deve mostrar como ele auxilia na obtenção e demonstração de um grau de proteção adequado e comprovar que as condições de trabalho continuam satisfatórias com o transcorrer do tempo. Para o controle operacional das exposições à radiação ionizante em qualquer local de trabalho, a Comissão Internacional de Proteção Radiológica (CIPR) recomenda um programa de proteção radiológica operacional, proporcional ao grau de risco, para garantir o gerenciamento efetivo das medidas necessárias para se satisfazer o principio da otimização. O presente trabalho de pesquisa tem como premissa o potencial das Tecnologias da Informação e Comunicação (TIC) como ferramenta para a comunicação e disseminação do conhecimento em Proteção Radiológica. O trabalho inclui a informatização da filosofia e técnica do monitoramento e sua otimização, unificando e inter-relacionando informações advindas de diversas publicações nacionais e internacionais, oferecendo às instalações radiativas brasileiras um veículo completo para informação e pesquisa, que permite dimensionar os esforços de otimização tornando-os eficazes e justificados. O sistema oferece ainda tópicos de discussões no intuito de ampliar o repertório dos profissionais do campo da proteção radiológica, suscitando novas reflexões a favor da segurança. Trata-se dos temas desenvolvidos nesta tese, a saber: a necessidade de um monitoramento auditor e discussões mais aprofundadas sobre as exposições potenciais. As reflexões propostas na presente tese vêm ao encontro das novas exigências internacionais, propondo ações passíveis de serem incorporadas na prática laboral. Dentro dos princípios da proteção radiológica, a implementação de um programa de monitoramento auditor permite avaliar se os critérios e ações previamente estabelecidas pelo Serviço de Proteção Radiológica são ou não atendidos, se foram implementados com eficácia e se permanecem adequados. Os fatos resultantes dos procedimentos de auditoria auxiliam a detectar deficiências no processo, possibilitando conclusões e recomendações diante de possíveis fatores desencadeadores de exposições indevidas. Por meio de exames sistemáticos das atividades realizadas em cada tipo de monitoramento, a auditoria infere segurança ao processo, respaldando o trabalhador na realização do monitoramento relacionado com a tarefa e respaldando a instalação, que empreende ações responsáveis a favor da segurança. Em relação às exposições potenciais, somente duas publicações da CIPR são expressivas e desenvolvem o assunto. Entretanto, ainda que forneçam a fundamentação teórica, são incompletas em seus exemplos. Há uma grande falta de conhecimento das probabilidades de falhas, o que atualmente constitui um vasto campo de pesquisa da proteção radiológica. A presente tese propõe, a partir de árvores de falhas, caminhos que auxiliam a quantificar probabilisticamente a ocorrência das exposições potenciais e a probabilidade de se atingir um determinado valor da dose. Acreditamos que o potencial das TIC contribuirá largamente para a disseminação da informação para as instalações radiativas, estimulando o desenvolvimento neste país de grandes extensões territoriais, onde permanece um desafio oferecer o acesso à informação ao maior número de pessoas possível, minimizando custos e maximizando resultados. / A monitoring program for the purposes of radiological protection should demonstrate an adequate protection degree and prove that working conditions remain appropriate as time goes by. For operational control of exposures to ionizing radiation in any workplace, the International Comission on Radiation Protection (ICRP) recommends establishing a program of operational radiation protection, proportional to the risk, to ensure the effective management of all necessary measures to satisfy the principle of optimization. This research work focus on the potential value of Information and Communication Technologies (ICTs) to enhance communication and education on Radiological Protection throughout Brazil. The work includes the informatization of the monitoring policy and techniques, interrelating information currently scattered in several documents, providing Brazilian radioactive facilities a complete repository for research, consultation and information, which allows to size optimization efforts by technology, enabling them to be effective and justified. The content of monitoring programs involves not only the collection and interrelationship of existing information in the publications, but also new approaches from some recommendations, presenting some initiatives towards safety. In this sense, the two contents researched and expanded are: the need for an auditor monitoring and discussions on potential exposures. The recommendations proposed in this thesis meet the new international requirements stablished by the International Agency of Nuclear Energy (IAEA) and propose appropriate actions to be incorporated into labor practice. Respecting the scope of the principles of radiological protection, an auditing program permits to evaluate whether criteria and actions previously established by Radiological Protection Service are effectively implemented and remain appropriate as time goes by. The results of auditing procedures help to detect deficiencies in the process, enabling conclusions and recommendations, avoiding possible triggers of undue exposures. Through systematic examinations of activities in each type of monitoring, auditing attempt to ensure the process, supporting the employee in performing task-related monitoring and support the facility that choose responsible actions towards safety. Furthermore, regarding potential exposures, only two publications of ICRP develop expressively the issue. Even though these publications provide the fundamental theory, they are incomplete in their examples. There is still lack of knowledge of failure probabilities, which currently constitutes a broad research field in radiological protection. This research work proposes the development of fault trees, suggesting paths to quantify probabilistically the occurrence of potential exposures, as well as probabilities to reach a certain level of dose. We believe that the potential of ICT shall contribute greatly to provide information where it is needed, stimulating development in this large country where it is a strong challenge to ensure access to information to as many people as possible, minimizing costs and optimizing results.
|
48 |
A flexibilização da competência e do processo normativo em relação à segurança e a proteção radiológica / The flexibility of competence and regulatory process regarding safety and radiation protectionAna, Vanessa da 09 December 2016 (has links)
O uso e a aplicação cada vez mais constante da tecnologia nuclear consistente em áreas relacionadas à saúde, energia, industrial, bélica, agrícola, entre outras, faz com que haja a necessidade de uma regulamentação de acordo com os padrões de segurança e proteção radiológica internacionais. Dessa forma, utilizando-se de conceitos provenientes do Direito Constitucional, do Direito Ambiental e do Direito do Trabalho, o enfoque da presente pesquisa foi investigar a difícil questão da competência nuclear e a competência ambiental, a impossibilidade de legislar dos Estados, bem como a falta de regulamentação sobre Rejeitos radioativos. Para tanto, foram atualizados e revisados critérios e métodos de interpretação constitucional para solucionar possíveis antinomias jurídicas advindas de múltipla positivação de normas pelos entes federados que dificultam tanto o asseguramento quanto o aprimoramento da Proteção radiológica do trabalhador e do meio ambiente. Finalmente, a hipótese considerada demonstrou que as mudanças na estrutura legislativa nas três esferas de poderes são necessárias, visando à aplicabilidade de responsabilidade legal na esfera nuclear, principalmente no que se refere às entidades administrativas e estatais. / The use and increasingly steady application of consistent nuclear technology in areas related to health, energy, industrial, war, agriculture, among others, means that there is a need for regulation in accordance with the safety standards and international radiological protection . Thus, using concepts from the Constitutional Law, Environmental Law and Labor Law, the focus of this research was to investigate the difficult issue of nuclear competence and environmental responsibility, the impossibility of legislating states, as well as the lack of regulation on radioactive waste. Therefore, it has been updated and revised criteria and methods of constitutional interpretation to solve possible legal antinomies arising from multiple positivation of the federal entities rules that hinder both the assurance and the improvement of radiation protection of workers and the environment. Finally, the working hypothesis has shown that changes in the legislative framework in the three spheres of power is needed in order to applicability of legal liability in the nuclear sphere, especially with regard to administrative and state entities
|
49 |
Avaliação do conhecimento e atitudes dos profissionais de saúde de um hospital de ensino sobre proteção radiológica / Assessment of knowledge and attitudes of health professionals from a university hospital about radiation protectionBatista, Vinicius Martins Dias 14 March 2017 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2017-03-27T10:21:54Z
No. of bitstreams: 1
Vinicius Martins Dias Batista.pdf: 1543209 bytes, checksum: 0d8e882a87ce71946ea5ad1860282d27 (MD5) / Made available in DSpace on 2017-03-27T10:21:54Z (GMT). No. of bitstreams: 1
Vinicius Martins Dias Batista.pdf: 1543209 bytes, checksum: 0d8e882a87ce71946ea5ad1860282d27 (MD5)
Previous issue date: 2017-03-14 / Background: The concept of radioprotection is usually recognized as important among the technical level of health professionals and higher. However, the information on the formal knowledge and its application in practice are scarce. Noticing the discrepancy in radiation protection process in sectors using ionizing radiation, decided to search the knowledge that health professionals have on radiation protection and the need for educational intervention for professionals to work consciously and with adequate protection. Objectives: To assess the knowledge that the health professionals of a university hospital (UH) have about radioprotection, educate staff about the harmful effects of ionizing radiation and application of the ALARA (As Low As Reasonably Achievable) principle in routine work and implement the knowledge of radioprotection through playful learning using teaching materials and easy to understand. Methods: This is an exploratory cross-sectional study with a qualitative analysis of the open questions and the quantitative issues addressed by a semi-structured questionnaire was applied to 59 employees from different sectors of UH to assess the degree of knowledge. From the findings it was prepared a booklet with playful images to be distributed to all employees of the UH. In the internal prevention week of work accidents at the UH it was made by the employees a performance about radioprotection. Results: According to the participants with technical or graduated degree, they did not have training on radiation protection as students or it was insufficient to practice. The work environment, even in a UH, provides little information about radiation protection and the rules which govern it. Much of the respondents (25%) even knowing not observe the radiation protection procedures. In the assessment of formal knowledge on the concept and the usual measures of radioprotection we observed that 1/3 of the participants have good theoretical knowledge, 1/3 have incomplete knowledge and 1/3 is completely unaware of the concept and radioprotection actions. Conclusion: The employees of a UH, even at graduated level, need training on radiation protection, because the training course failed in this respect. We believe the same should happen in other health institutions. The actions aimed at training in radiation protection were very well accepted by employees and their effective translation greater individual and collective protection is being evaluated / Introdução: O conceito de radioproteção é habitualmente reconhecido como importante entre os profissionais de saúde de nível técnico e superior, porém, são escassas as informações sobre o conhecimento formal e sua aplicação na prática. Percebendo a defasagem no processo de proteção radiológica nos setores que utilizam radiação ionizante, resolvi pesquisar o conhecimento que os profissionais da saúde têm sobre proteção radiológica e a necessidade de intervenção educativa para que os profissionais trabalhem de forma consciente e com proteção adequada. Objetivos: Avaliar o conhecimento que os profissionais de saúde de um hospital de ensino (HE) têm sobre radioproteção; conscientizar as equipes sobre os efeitos danosos das radiações ionizantes e aplicação do princípio ALARA (As Low As Reasonably Achievable) na rotina de trabalho e implementar o conhecimento sobre radioproteção através do ensino lúdico utilizando material didático e de fácil compreensão. Métodos: Trata-se de um estudo transversal exploratório com análise qualitativa das questões abertas e quantitativa das questões dirigidas. Foi aplicado um questionário semiestruturado a 59 funcionários dos diferentes setores do HE para avaliar o grau de conhecimento existente. A partir dos achados foi elaborada uma cartilha com imagens lúdicas para ser distribuída a todos os funcionários do HE. Na semana interna de prevenção de acidentes de trabalho do HE foi feita pelos funcionários teatralização sobre a radioproteção. Resultados: Na opinião dos participantes o curso técnico ou superior que fizeram não forneceu formação sobre radioproteção ou esta foi insuficiente para a prática. O ambiente de trabalho, mesmo em um HE, disponibiliza poucas informações sobre radioproteção e as normas que a regem. Boa parte dos entrevistados (25%) mesmo tendo conhecimento não observam as medidas de radioproteção. Na aferição do conhecimento formal sobre o conceito e as medidas habituais de radioproteção observamos que 1/3 dos participantes tem bom conhecimento teórico, 1/3 tem conhecimento incompleto e 1/3 desconhece completamente o conceito e as ações de radioproteção. Conclusão: Os funcionários de um HE, mesmo os de nível superior, têm necessidade de capacitação sobre radioproteção, pois o curso de formação falhou neste aspecto. Acreditamos que o mesmo deve acontecer em outras instituições de saúde. As ações objetivando a capacitação em radioproteção foram muito bem aceitas pelos funcionários e sua tradução efetiva em maior proteção individual e coletiva está sendo avaliada
|
50 |
A flexibilização da competência e do processo normativo em relação à segurança e a proteção radiológica / The flexibility of competence and regulatory process regarding safety and radiation protectionVanessa da Ana 09 December 2016 (has links)
O uso e a aplicação cada vez mais constante da tecnologia nuclear consistente em áreas relacionadas à saúde, energia, industrial, bélica, agrícola, entre outras, faz com que haja a necessidade de uma regulamentação de acordo com os padrões de segurança e proteção radiológica internacionais. Dessa forma, utilizando-se de conceitos provenientes do Direito Constitucional, do Direito Ambiental e do Direito do Trabalho, o enfoque da presente pesquisa foi investigar a difícil questão da competência nuclear e a competência ambiental, a impossibilidade de legislar dos Estados, bem como a falta de regulamentação sobre Rejeitos radioativos. Para tanto, foram atualizados e revisados critérios e métodos de interpretação constitucional para solucionar possíveis antinomias jurídicas advindas de múltipla positivação de normas pelos entes federados que dificultam tanto o asseguramento quanto o aprimoramento da Proteção radiológica do trabalhador e do meio ambiente. Finalmente, a hipótese considerada demonstrou que as mudanças na estrutura legislativa nas três esferas de poderes são necessárias, visando à aplicabilidade de responsabilidade legal na esfera nuclear, principalmente no que se refere às entidades administrativas e estatais. / The use and increasingly steady application of consistent nuclear technology in areas related to health, energy, industrial, war, agriculture, among others, means that there is a need for regulation in accordance with the safety standards and international radiological protection . Thus, using concepts from the Constitutional Law, Environmental Law and Labor Law, the focus of this research was to investigate the difficult issue of nuclear competence and environmental responsibility, the impossibility of legislating states, as well as the lack of regulation on radioactive waste. Therefore, it has been updated and revised criteria and methods of constitutional interpretation to solve possible legal antinomies arising from multiple positivation of the federal entities rules that hinder both the assurance and the improvement of radiation protection of workers and the environment. Finally, the working hypothesis has shown that changes in the legislative framework in the three spheres of power is needed in order to applicability of legal liability in the nuclear sphere, especially with regard to administrative and state entities
|
Page generated in 0.068 seconds