• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 1
  • Tagged with
  • 18
  • 18
  • 18
  • 16
  • 16
  • 14
  • 8
  • 7
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação dos métodos de previsão e controle de capacidade de carga em estacas tipo perfil metálico “H”

Inácio da Silva, Leandro 31 January 2013 (has links)
Submitted by Romulus Lima (romulus.lima@ufpe.br) on 2015-03-10T13:53:40Z No. of bitstreams: 2 Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-10T13:53:40Z (GMT). No. of bitstreams: 2 Dissertação Leandro Inacio da Silva.pdf: 10343622 bytes, checksum: c57f859f206fc18bfb4d6b53cb664f29 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2013 / CAPES / O presente trabalho avalia a capacidade de carga obtida através de diversos métodos: semiempíricos (Aoki-Velloso (1975), Décourt-Quaresma (1978, 1982) e de Teixeira (1996)); métodos dinâmicos (Fórmulas de Brix, Holandeses, Velloso (1987), Rosa (2000) e Uto et al (1985)) para 25 estacas metálicas perfil “H”, através de ensaios de carregamento dinâmicos de energia crescente (programa CASE e CAPWAP) e prova de carga estática. As estacas foram executadas em uma edificação localizada em Paulista-PE. Os resultados obtidos pelos métodos semiempíricos apresentaram comportamento conservador quando comparados com os resultados de ensaio de carregamento dinâmico e prova de carga estática, sendo o método de Aoki-Velloso (1975) o que teve melhor aproximação. As fórmulas dinâmicas com base nos dados de nega mostraram-se extremamente conservadoras na estimativa da capacidade de carga, diferente dos resultados obtidos das fórmulas com base no repique elástico que apresentaram resultados com boa correlação. Em relação aos resultados obtidos pelo programa CASE e os obtidos em provas de carga estática mostram que a depender das circunstâncias, o ensaio de carregamento dinâmico pode superestimar a capacidade de carga.
2

Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soils

Benvenutti, Márcio 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
3

Comportamento de radiers estaqueados assentes em solos arenosos

Bittencourt, Eduardo de Castro 06 April 2018 (has links)
Submitted by Automação e Estatística (sst@bczm.ufrn.br) on 2018-07-03T11:24:44Z No. of bitstreams: 1 EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2018-07-09T13:57:00Z (GMT) No. of bitstreams: 1 EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5) / Made available in DSpace on 2018-07-09T13:57:00Z (GMT). No. of bitstreams: 1 EduardoDeCastroBittencourt_DISSERT.pdf: 5316061 bytes, checksum: be3a5cddd8a4237ce02148bbeb4f2961 (MD5) Previous issue date: 2018-04-06 / Observa-se nas últimas décadas, a busca da otimização de fundações estaqueadas a partir da consideração do benefício que o contato do bloco ou radier com o solo pode conferir para aumento de capacidade de carga e aumento de rigidez. Contribuição que não é inserida no dimensionamento do sistema de fundação pela metodologia tradicional de grupo de estacas. Assim, nesta dissertação foi realizada uma análise do comportamento de uma fundação que foi concebida pela metodologia de grupo de estacas, à luz da técnica de radier estaqueado, através de modelagens numéricas. A obra em estudo é do Instituto do Cérebro, localizada no Campus Central da Universidade Federal do Rio Grande do Norte (UFRN), cidade de Natal-RN. Pesquisas teóricas e experimentais, destacando trabalhos pioneiros e mais recentes a respeito da temática deste trabalho, foram utilizados como subsídios para apresentar o estado da arte de fundações em radier estaqueado. A fundação analisada é constituída por estacas escavadas do tipo hélice contínua, com comprimentos de 15, 17 e 20 m e diâmetros de 250, 400 e 500 mm. Para análise do comportamento desta fundação, foi utilizado o programa numérico PLAXIS 3D Foundation, baseado no Método dos Elementos Finitos (MEF). Para averiguar se o programa foi manuseado de maneira correta, foi realizada a verificação do software por meio de análises comparativas de casos previamente estudados por outros pesquisadores. Os dados de entrada do programa e retroanálise dos parâmetros geotécnicos do solo foram subsidiados por ensaios de simples reconhecimento (SPT), realizados em campo conforme procedimentos recomendados pela NBR 6484/2001 e provas de carga estática em estaca (PCE), realizadas segundo método de execução apresentado na NBR 12131/2006. O subsolo local, modelado assumindo o seu comportamento elástico perfeitamente plástico, é formado por camadas de areia fina e média, pouco siltosa, compacta, até atingir o impenetrável. Observou-se nos resultados obtidos que a interação do bloco de fundação incrementou a capacidade de carga e a rigidez do sistema. O bloco de fundação apresentou até 21% de contribuição no recebimento dos esforços aplicados na fundação. Além disso, observou-se que a capacidade de carga do sistema de fundação em radier estaqueado não se configura apenas na soma algébrica das resistências isoladas do bloco e estaca(s). Diante destes resultados, pode-se concluir que a metodologia de fundação em radier estaqueado se configura como uma técnica positiva para a cidade de Natal para obras de médio porte. / It is observed in the last decades, the search of the optimization of pile foundations from the analysis of the benefit that the contact of the pile cap or raft with the ground can confer to increase the load capacity and stiffness. Contribution that is not inserted in the design of the foundation system by the traditional methodology of pile group. Thus, in the present dissertation an analysis of the behavior of a foundation conceived by the pile group methodology was carried out, in light of the piled raft, through numerical modeling. The study work is from Instituto Cérebro, located in the Central Campus of the Federal University of Rio Grande do Norte (UFRN), Natal-RN. Theoretical and experimental studies, highlighting pioneering and more recent searchs on the theme of this work, were used as subsidies to present the state of the art of foundations in piled raft. The study foundation consists of bored piles of the continuous flight auger, composed of lengths of 15, 17 and 20 m and diameters of 250, 400 and 500 mm. For the analysis of the behavior of this foundation, the numerical program PLAXIS 3D Foundation, based on the Finite Element Method (FEM). To verify if the program was handled correctly, the verification of the software was done through comparative analysis of cases previously studied by other researchers. The program input data and back-analysis of soil geotechnical parameters were subsidized by Standard Penetration Test (SPT), carried out in the field according to the procedures recommended by NBR 6484/2001 and static load tests (PCE), carried out according in NBR 12131/2006. The local subsoil, which was modeled assuming its elastic behavior perfectly plastic, is formed by layers of fine and medium sand, little compact silt, until reaching the impenetrable. The water level was not detected in any of the 13 boring performed. It was observed in the results obtained that the interaction of the pile cap with the soil increased the load capacity and stiffness of the system. The pile cap presented up to 21% contribution in receiving the efforts applied in the foundation. In addition, it has been observed that the load capacity of the piled raft foundation system is not confined to the algebraic sum of the isolated resistances of the pile cap and pile(s). Considering these results, it can be concluded that the methodology of foundation in piled raft is configured as a positive foundation technique for the city of Natal for medium-sized buildings.
4

Cravação de tubulões a céu aberto para melhoria da capacidade de carga em solos colapsíveis / Driving of belled piles to improve bearing capacity on collapsible soils

Márcio Benvenutti 08 November 2001 (has links)
Os tubulões a céu aberto são amplamente utilizados como elementos estruturais de fundação de edifícios residenciais nas cidades pequenas e médias do Brasil. Relatam-se as etapas de um projeto de fundações por tubulões desenvolvido em uma área previamente ocupada por construções residenciais antigas. Após cuidadosa demolição e limpeza, deparou-se com o desafio de executar as fundações sem o perigo de danificar as construções adjacentes (tubulões à céu aberto de divisa nos dois lados e no fundo). No projeto, utilizaram-se procedimentos usuais e alguns específicos que refletem a prática corrente nos últimos 10 anos, na região de Campinas, com resultados extremamente satisfatórios. Nos solos porosos e colapsíveis, presentes em várias regiões brasileiras, as fundações não raramente têm apresentado comportamento inadequado, quando o solo é inundado. Com a significativa elevação do seu teor de umidade, esses solos exibem o recalque de colapso, caracterizando-se como colapsíveis. Como já se tem a comprovação da eficiência da compactação do solo para viabilizar o emprego de fundações rasas, por sapatas, em solos colapsíveis (CINTRA, 1998), resolveu-se estudar os possíveis benefícios da criação de tubulões a céu aberto. No campo experimental de Fundações da USP/São Carlos, foram executadas dois tubulões a céu aberto com fuste de diâmetro de 0,50 m e base apoiada à cota - 6,00 m, com diâmetro de 1,50 m e altura de 0,90 m. O primeiro tubulão a céu aberto foi ensaiado na condição não-inundada do solo, na cota inicial de apoio da base e sucessivamente, com a cravação de 0,15 m, 0,30 m e 0,45 m, o que corresponde a 10%, 20% e 30% do diâmetro da base, respectivamente. Observou-se que a cravação majorou a capacidade de carga em 42%, 85% e 12%, respectivamente. O segundo tubulão a céu aberto foi ensaiado com o solo pré-inundado, para quantificar o efeito da colapsibilidade do terreno na redução da capacidade de carga. ) Constatou-se uma redução de 51% a 53% nos valores de capacidade de carga anteriormente obtidos. Mas a carga de colapso, ou capacidade de carga na condição inundada, também teve uma majoração importante, aumentando em 45%, 90% e 135% com a cravação de 10%, 20% e 30% do diâmetro da base, respectivamente. Conclui-se que a cravação de tubulões a céu aberto, inicialmente executados com escavação e concretagem in situ, pode ser uma solução interessante em solos colapsíveis. / The belled piles are largely used as fundation for structural elements of residential buildings in small and medium cities in Brazil. The steps of a foundation design is developed in an area previously occupied by old residential buildings. After a careful demolition and clean up process, the challenger is to build the foundations without the danger of harming the adjacent buildings (Division of belled piles on both side and on the bottom). On the design, some specific and some standard procedures are used, which reflect the current practice over the last 10 years, in the Campinas region, with extremely satisfactory results . In porous and collapsible soil, that can be found in many Brazilian regions, these piles usually have presented an inadequate behavior, when the soil is soaked. With a significant elevation on its moisture content, these soils present the collapse settlement, being characterized as collapsible. Since there is already the confirmation of the compacting process efficacy in making the employment of shallow foundations on collapsible soils feasible (CINTRA, 1998), it was decided to study the possible benefits of driving the belled piles on the improvement of the bearing capacity. At the Experimental Foundation Field of USP/São Carlos, two piles were tested. Both piles were 6,00 m long and had a shaft diameter of 0.50 m. The enlarged bases had a diameter of 1.50 m and a height of 0.90 m. The first pile was tested under the non-soaked condition of the soil, on the initial quota of base support, and then with the 0.15 m, 0.30 m and 0.45 driving, which corresponds to 10%, 20%, and 30% of the base diameter, respectively. It was observed that the driving improved the bearing capacity in 42%, 85%, and 127%, respectively. The second pile was tested on a soaked soil, to quantity the collapsibility effect on the reduction of the bearing capacity. A reduction of 51% to 53% on the values of the bearing capacity previously obtained was observed, but the collapse load, also presented an important improvement, increasing 45%, 90%, and 135% with the driving of 10%, 20%, and 30% of the base diameter, respectively. We can conclude that the driving of belled piles, inittially executed with digging and concreting in situ, may be an interesting solution on collapsible soils.
5

Estacas de compactação para melhoria de solo / Compaction piles to soil improvement

Soares, Wilson Cartaxo 18 December 2002 (has links)
Este trabalho apresenta alguns parâmetros geotécnicos do solo arenoso na região litorânea de João Pessoa/PB, após a melhoria com estacas de compactação, instaladas pelo método denominado vibro-deslocamento. Esse procedimento é um método de melhoria de solos arenosos em que as estacas de areia e brita são introduzidas em solos de baixa resistência com o propósito de aumentar sua resistência e diminuir os recalques da fundação. Realizaram-se ensaios de cone, prova de carga em placa, sondagem SPT e anotação do diagrama de cravação das estacas, para se estudarem os efeitos da melhoria do solo arenoso por meio de estacas de compactação. São mostradas correlações entre o 'N IND.SPT', antes e após a compactação do solo, entre a resistência de ponta do cone e 'N IND.SPT', antes e após a compactação, bem como os resultados de provas de carga em placa, realizadas nos solos natural e compactado. Observou-se que a diminuição do espaçamento entre estacas aumenta a resistência do solo. Com base no 'N IND.SPT', é apresentada uma forma de previsão da capacidade de carga de fundações por sapata, instaladas em solo arenoso compactado com estacas de areia / This work presents some geotechnical parameters in sandy soil improved by compaction piles installed by vibro-displacement on the cost of the city of João Pessoa in Northeastern Brazil. Significant increases on bearing capacity can be achieved with this ground improvement technique allowing the use of shallow foundation, even in the case of high buildings. Forty eight sand piles with diameter of 0,30 m and 3,5 m long were installed on three different groups varying distance between the piles. Standard penetration tests, cone penetration tests and plate load tests were carried out before and after the installation of piles. The comparison between the tests allows quantify the benefit of soil improvement by compaction piles. Empirical relationships between 'N IND.SPT' before and after improvement, and relationships between qc and 'N IND.SPT' were established. These relations and results of plate load tests allowed an assessment of the influence of distance between the piles in the compacted soil. A prediction of bearing capacity of shallow foundations in sandy soil improved by sand piles, based on 'N IND.SPT' values is presented
6

Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the sampler

Neves, Luis Fernando de Seixas 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
7

Estacas de compactação para melhoria de solo / Compaction piles to soil improvement

Wilson Cartaxo Soares 18 December 2002 (has links)
Este trabalho apresenta alguns parâmetros geotécnicos do solo arenoso na região litorânea de João Pessoa/PB, após a melhoria com estacas de compactação, instaladas pelo método denominado vibro-deslocamento. Esse procedimento é um método de melhoria de solos arenosos em que as estacas de areia e brita são introduzidas em solos de baixa resistência com o propósito de aumentar sua resistência e diminuir os recalques da fundação. Realizaram-se ensaios de cone, prova de carga em placa, sondagem SPT e anotação do diagrama de cravação das estacas, para se estudarem os efeitos da melhoria do solo arenoso por meio de estacas de compactação. São mostradas correlações entre o 'N IND.SPT', antes e após a compactação do solo, entre a resistência de ponta do cone e 'N IND.SPT', antes e após a compactação, bem como os resultados de provas de carga em placa, realizadas nos solos natural e compactado. Observou-se que a diminuição do espaçamento entre estacas aumenta a resistência do solo. Com base no 'N IND.SPT', é apresentada uma forma de previsão da capacidade de carga de fundações por sapata, instaladas em solo arenoso compactado com estacas de areia / This work presents some geotechnical parameters in sandy soil improved by compaction piles installed by vibro-displacement on the cost of the city of João Pessoa in Northeastern Brazil. Significant increases on bearing capacity can be achieved with this ground improvement technique allowing the use of shallow foundation, even in the case of high buildings. Forty eight sand piles with diameter of 0,30 m and 3,5 m long were installed on three different groups varying distance between the piles. Standard penetration tests, cone penetration tests and plate load tests were carried out before and after the installation of piles. The comparison between the tests allows quantify the benefit of soil improvement by compaction piles. Empirical relationships between 'N IND.SPT' before and after improvement, and relationships between qc and 'N IND.SPT' were established. These relations and results of plate load tests allowed an assessment of the influence of distance between the piles in the compacted soil. A prediction of bearing capacity of shallow foundations in sandy soil improved by sand piles, based on 'N IND.SPT' values is presented
8

Metodologia para a determinação da eficiência do ensaio SPT através de prova de carga estática sobre o amostrador padrão / Methodology to determine the SPT efficiency through static load test over the sampler

Luis Fernando de Seixas Neves 23 March 2004 (has links)
O ensaio de simples reconhecimento de solos (SPT) é a ferramenta de investigação de solos mais utilizada no mundo. Devido ao grande número de parâmetros que influenciam os seus resultados, a medida de sua eficiência passa a ser indispensável à transposição de experiências entre as práticas desenvolvidas em diferentes locais. Infelizmente, a medida da eficiência através da instrumentação do impacto do martelo é economicamente inviável para a maioria das empresas de sondagem no Brasil. Este trabalho apresenta uma metodologia para a determinação da eficiência do SPT baseada no princípio de Hamilton e na realização de prova de carga estática sobre o amostrador, que pode ser uma alternativa para sanar esta situação. / The standard penetration test (SPT) is the most used soil investigation tool in the world. Due to the great number of variables that influences its results, the measurement of the efficiency becomes imperative to the transposition of experiences between developed practices in different places. Unfortunately, the measurement of the efficiency through the instrumentation of the hammer impact is economically inpracticable to most of the soil investigation firms in Brazil. This work presents a methodology to determinate the SPT efficiency based on the Hamilton\'s principle and on the execution of static load test over the sampler, what seems to be a good alternative to end this situation.
9

Novo procedimento para a realização de análise capwap no ensaio de carregamento dinâmico em estacas pré-moldadas. / New prodedure to perform CAPWAP analysis on dinamic load test in precast concrete piles.

Murakami, Daniel Kina 01 October 2015 (has links)
Desde a década de 1980 diversos autores apresentaram correlações entre provas de carga estática e ensaios de carregamento dinâmico em estacas. Para uma boa correlação é fundamental que os testes sejam bem executados e que atinjam a ruptura segundo algum critério, como o de Davisson, por exemplo, além de levar em conta o intervalo de tempo entre a execução da prova de carga estática e do ensaio dinâmico, face ao efeito \"set up\". Após a realização do ensaio dinâmico realiza-se a análise CAPWAP que permite a determinação da distribuição do atrito lateral em profundidade, a carga de ponta e outros parâmetros dos solos tais como quakes e damping. A análise CAPWAP é realizada por tentativas através do procedimento \"signal matching\", isto é, o melhor ajuste entre os sinais de força medido pelos sensores e o calculado. É relativamente fácil mostrar que a mesma solução pode ser obtida através de dados de entrada diferentes. Isso significa que apesar de apresentarem cargas mobilizadas próximas o formato da curva da simulação de prova de carga estática, obtida pelo CAPWAP, assim como a distribuição do atrito lateral, podem ser diferentes, mesmo que as análises apresentem \"match quality\" (MQWU) satisfatórios. Uma forma de corrigir o formato da curva simulada do CAPWAP, assim como a distribuição do atrito lateral, é através da comparação com provas de carga estática (PCE). A sobreposição das duas curvas, a simulada e a \"real\", permite a determinação do quake do fuste através do trecho inicial da curva carga-recalque da prova de carga estática, que por sua vez permite uma melhor definição da distribuição do atrito lateral e da reação de ponta. Neste contexto surge o conceito de \"match quality de recalques\" (MQR). Quando a PCE não está disponível, propõe-se efetuar um carregamento estático utilizando o peso próprio do martelo do bate-estaca (CEPM). Mostra-se, através de dois casos de obra, em que estavam disponíveis ensaios de carregamento dinâmico e PCEs, que esse procedimento permite obter uma melhor solução do ponto de vista físico, isto é consistente com as características do subsolo e com a curva carga-recalque da PCE, e não apenas matemático, através da avaliação do \"match quality\" (MQWU). / Since the 1980s a lot of authors showed correlations between static load tests and dynamic load tests on piles. For a good correlation it is necessary a good execution of the load test, also it is necessary to choose a capacity value from the results of the static load test, for example, the Davisson Offset limit load. The time of execution between the static load test and the dynamic load test should be considered because of the set up effect. Dynamic data may be further analyzed by CAPWAP Method to evaluate the soil resistance distribution, the toe resistance, quake and damping values. It is a signal matching method. Its results are based on the \"best possible match\" between computed pile top variable such as the pile top force and its measured equivalent. It is easy to demonstrate almost the same pile capacity on CAPWAP using different soil parameters. It means that even the pile capacity is almost the same, the shape of the pile top load-displacement of the CAPWAP Method and the shaft friction distribution can be different, although all results confirm good match quality. One way to correct the shape of the top loaddisplacement of the CAPWAP Method, as well as the shaft friction distribution, is by comparisson to a static load test. Overlaying both curves, the static load test and the CAPWAP Method, it is possible to determine the shaft quake value on the initial loads on the top load-displacement curve, allowing this way a improvement of the shaft resistance distribution and the toe resistance. In this context arises the concept of \"match quality of settlements\". When the static load test is not avaliabe, this thesis proposes a static load test using the hammer\'s weight of the pile driving machine. It is shown by two case studies that were available static load tests and dynamic load tests, this procedure allows a better solution on physics aspects, this is consistent with the subsoil conditions and the load-settlement curve of the static load test, not only a mathematical solution based on match quality.
10

Análise de provas de carga dinâmica em tubulões a céu aberto no campo experimental de fundações da EESC/USP / Analysis of dynamic loading test in large diameter bored piles, in the experimental field of EESC

Soares, Fábio Lopes 13 March 2003 (has links)
Apresenta-se o conceito de elemento isolado de fundação em tubulão, e analisa-se 10 provas de carga dinâmica de energia crescente, nos tubulões, considerando as provas de carga estática realizadas anteriormente nos mesmos. Os ensaios são realizados em tubulões a céu aberto, situados em maciço de solo da formação Rio Claro e Itaqueri, no campo experimental de fundações da USP/EESC. As análises baseiam-se em curvas de resistência x deslocamento e gráficos que mostram a evolução da resistência mobilizada com o aumento da energia aplicada, resultantes dos impactos do ensaio dinâmico de energia crescente (metodologia PDA e análises CAPWAP). Analisam-se também a influência da pré-inundação e da variação da sucção do maciço de solos nos ensaios dinâmicos, o efeito do reensaio e a variabilidade nos resultados de ensaios de investigação geotécnica (SPT e CPT), realizados no campo experimental. Os resultados das provas de carga dinâmica de energia crescente mostram que a resposta do sistema isolado de fundação em tubulão é diferente a cada nível de energia aplicada e que a história de carregamento do elemento isolado de fundação é de extrema importância para análise dos ensaios nele realizado. / The concept of an isolated foundation element in large diameter bored pile is presented and 10 dynamic loading tests with increased energy are analysed. The interpretation of the dynamic loading tests has been proceeded with due consideration of the results of static loading tests performed previously. The loading tests have been carried out in large diameter bored piles founded in Rio Claro and Itaqueri soil formation, situated in the experimental foundation field of USP/EESC. The analyses are based on resistance x displacement curves and selected graphics illustrating the development of mobilized resistance with increasing applied energy during a dynamic loading test (PDA methodology and CAPWAP type analysis). The influence of previous inundation in soil mass and suction variation are also analysed, as well as the effect of test repetition and variability in SPT and CPT results. The results obtained with the dynamic loading tests with increasing energy revealed a distinct behaviour of the isolated foundation system for each level of applied energy, showing that the loading history is an aspect of extreme relevance to an adequate analysis of the dynamic tests perfomed.

Page generated in 0.0871 seconds