• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • Tagged with
  • 17
  • 17
  • 7
  • 7
  • 7
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Avaliação de um modelo experimental para estudos radiográficos em endodontia

Maurício Augusto Aquino de Castro 26 January 2007 (has links)
Diversos procedimentos endodônticos dependem da utilização das radiografias periapicais. O exame convencional ainda é o método de eleição para a prática clínica, a despeito dos avanços trazidos com os sistemas digitais e com os localizadores eletrônicos. Ocorre, porém, que nos estudos científicos não se verifica adequada padronização quanto aos modelos de estudo utilizados. Ao mensurar e comparar a densidade óptica das imagens do canal e dentina radicular de radiografias periapicais de um modelo experimental e de indivíduos vivos, este trabalho se propôs avaliar a viabilidade da utilização deste modelo em estudos endodônticos radiográficos. Após coleta de dados avalizada cientificamente pela utilização do aparelho fotodensitômetro (MRA), e análise estatística (Testes de Kolmogorov-Smirnof, Levene com correção de Bonferroni, Kruskal-Wallis, Mann-Whitney e de correlação de Pearson), observou-se que os resultados obtidos não evidenciaram diferenças estatisticamente significativas entre as radiografias do modelo e dos pacientes. Diante disso, conclui-se que o modelo experimental é adequado para a utilização em experimentos endodôntico-radiográficos. / Several endodontic procedures depend of dental radiographs. The conventional radiograph is the usual method to clinical practice, even the advances proportionate by digital systems and electronic apex locators. However, the endodontic studies dont display standardized radiographic models. Analyzing the optical density of the images from an experimental model and patients, based on digital photodensitometer (MRA), this study evaluated the viability of this model in endodontic studies. The Kolmogorov-Smirnof, Levene, Bonferronis correction, Kruskal-Wallis, Mann-Whitney and Pearsons correlation tests dont display statistical differences between images from patients and the model. Thus concluded that is adequate to use in radiographicendodontic studies.
12

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Pinheiro, Lucas Rodrigues 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
13

Identificação de dois canais radiculares em incisivos inferiores com imagens radiográficas, tomográficas e microtomográficas / Identification of two root canals in mandibular incisors using radiographic, tomographic and microtomographic images

Fernandes, Luciana Maria Paes da Silva Ramos 06 June 2014 (has links)
Os dentes incisivos inferiores apresentam, em sua maioria, canal radicular único, que pode ter conformações distintas. De acordo com a literatura científica, a presença de um segundo canal radicular pode ser constatada em 10 a 40% dos casos. A não-detecção do segundo canal é um importante fator para o insucesso do tratamento endodôntico. Esta pesquisa foi realizada com os seguintes objetivos: 1) comparar a eficácia na identificação de padrões anatômicos internos em incisivos inferiores permanentes extraídos com uso de imagem radiográfica periapical digital e de tomografia computadorizada de feixe cônico (TCFC); e 2) determinar a prevalência de 2 canais radiculares em incisivos inferiores em imagens de TCFC de um banco de dados de exames previamente realizados, associando com localização do dente, gênero e idade do paciente. Na primeira etapa da pesquisa, 40 dentes incisivos inferiores foram submetidos a escaneamento em microtomógrafo computadorizado da FOB-USP (Skyscan 1074) para estabelecer o padrão ouro do tipo anatômico interno de cada dente. Os dentes foram então classificados em: Tipo I (1 canal radicular regular, n=12), Tipo Ia (1 canal radicular oval, n=12) e Tipo III (2 canais radiculares, n=16). Em seguida, os dentes foram divididos em 10 grupos de 4 dentes e posicionados em alvéolos de uma mandíbula humana para exposição radiográfica periapical digital direta com duas tomadas variando o ângulo horizontal de incidência (Schick CDR) e para escaneamento em 3 tomógrafos (Kodak 9000 3D, Veraviewepocs 3De e NewTom 5G) da Universidade de Loma Linda, CA, EUA. Dois examinadores treinados classificaram o tipo anatômico de cada dente e suas respostas foram comparadas ao padrão ouro estabelecido por microtomografia. Para descrição dos resultados, utilizou-se a porcentagem (%) de respostas certas / erradas. Aplicou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%, para verificação da associação entre variáveis. As concordâncias inter e intraexaminador foram determinadas por teste de kappa. Na segunda etapa da pesquisa, foram interpretadas imagens de incisivos inferiores de 100 pacientes, cujos exames estavam disponíveis no banco de dados do tomógrafo i-CAT Classic da FOB-USP. Dois examinadores avaliaram a anatomia interna de incisivos inferiores, em reconstruções axiais, sagitais e coronais, classificando-a de acordo com o número de canais radiculares. A prevalência de 2 canais radiculares foi relacionada à localização do dente e ao gênero e idade do paciente. Para descrição dos dados coletados, utilizou-se a porcentagem (%). Para verificar a associação entre variáveis, utilizou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%. Para a concordância intra e interexaminador, utilizou-se o teste de kappa. Como resultado da primeira etapa da pesquisa, obteve-se alto índice de detecção de tipos anatômicos para todos os métodos avaliados (p <0,05). Para dentes com Tipo I (1 canal radicular regular), as imagens de TCFC foram superiores em comparação à radiografia periapical digital com dupla exposição (RP= 67% de acerto; TCFC= 98% de acerto, p <0,05). Considerando os 3 aparelhos de TCFC, não houve diferença estatística significante entre eles para identificação do Tipo I. Já para dentes com Tipo Ia (1 canal radicular oval), houve diferença estatística significante somente entre radiografia periapical digital com dupla exposição e o tomógrafo NewTom (RP= 44% de acerto; TCFC NewTom= 88% de acerto). Não houve diferença significante entre os outros 2 tomógrafos e radiografia periapical ou entre os 3 tomógrafos. Considerando dentes com Tipo III (2 canais radiculares), não houve diferença estatística significante entre nenhum dos métodos. Todos os métodos apresentaram números de respostas certas semelhantes para o Tipo III, sugerindo que a radiografia periapical com dupla angulação é suficiente para identificação de 2 canais radiculares em incisivos inferiores. A concordância intraexaminador para radiografia periapical foi regular (kappa=0,40 a 0,66) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,85). A concordância interexaminador para radiografia periapical foi de ruim a regular (kappa=0,25 a 0,32) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,92). Na segunda etapa da pesquisa, o total de 386 incisivos inferiores foi avaliado, sendo 192 incisivos centrais e 194 incisivos laterais. A prevalência de 2 canais radiculares constatada no total de dentes foi de 16,5%, sendo de 13% em incisivos centrais e de 20% nos incisivos laterais (p >0,05). Não houve diferença estatisticamente significante entre gêneros e idades. A concordância intra e interexaminador foi regular (kappa intra=0,60; kappa inter=0,57). Como conclusão da primeira etapa da pesquisa, observou-se que a identificação do número de canais radiculares foi efetiva em todos os métodos. No entanto, limitações foram encontradas para a diferenciação da forma do canal radicular. Na segunda etapa da pesquisa, concluiuse que a presença de 2 canais radiculares em incisivos inferiores de pacientes da região de Bauru é de aproximadamente 20% e não depende da localização do dente ou de gênero e idade do paciente. / Mandibular incisors most commonly have a single root canal, which can present with different anatomic configurations. According to the literature, the presence of a second root canal can be observed in 10 - 40% of the teeth. Difficulty in detecting the second root canal is an important factor for the endodontic treatment failure. The aim of this research was: 1) to compare the efficacy of digital periapical radiography (PA) with double exposure and cone beam computed tomography (CBCT) in the identification of internal anatomic patterns in mandibular incisors, and 2) to determine the prevalence of 2 root canals in mandibular incisors using cone beam computed tomographic images of a patient database, comparing to tooth position and patients gender and age. In the first part of this research, 40 extracted mandibular incisors underwent microcomputed tomographic (micro-CT) scanning (Skyscan 1074) in order to establish the gold standard for internal anatomic pattern. The teeth were classified according to: Type I (1 regular root canal, n=12), Type Ia (1 oval root canal, n=12), and Type III (2 root canals, n=16). Then, the teeth were divided into 10 groups of 4 teeth and placed in a preserved human mandible for direct digital periapical radiographic double exposure (Schick CDR) and CBCT scans using Kodak 9000 3D, Veraviewepocs 3De and NewTom 5G. Two blinded examiners classified the anatomic pattern of each tooth and their answers were compared to the gold standard (microtomographic images). Percentage (%) of right / wrong answers was used for the statistical analysis of the results. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. In the second part of this research, CBCT images of a 100 patients database from FOB-USP were examined. Two examiners assessed the internal anatomy of mandibular incisors in axial, sagittal and coronal reconstructions and classified the teeth according to the number of root canals. The prevalence of 2 root canals was related to the tooth location and patients gender and age. Percentage (%) was used to describe the collected data. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. The results of the first part of the research showed a high level of identification of anatomic patterns for all the methods (p <0.05). Considering Type I (1 regular root canal), CBCT images were better in comparison to PA (PA= 67%; CBCT= 98%, p <0.05). There was no significant difference between the 3 CBCT scanners. For Type Ia (1 oval root canal), there was a significant difference between PA and CBCT imaging using the NewTom unit only (PA= 44%, NewTom CBCT= 88%). No significant differences were found between the other 2 CBCT units and PA or between the 3 CBCT units. Considering Type III (2 root canals), there was no significant difference between the various methods. All the methods presented similar corrected answers index for Type III, which may suggest that PA with double exposure is sufficient for the identification of 2 root canals in mandibular incisors. The intraexaminer agreement was fair for PA (kappa=0.40 to 0.66) and good to very good for the CBCT units (kappa=0.62 to 0.85). The interexaminer agreement was poor to fair for PA (kappa=0.25 to 0.32) and good to very good for CBCT units (kappa=0.62 to 0.92). In the second part of this research, the total amount of 386 mandibular incisors was assessed in CBCT images (192 mandibular central incisors and 194 mandibular lateral incisors). The overall prevalence of 2 root canals was 16.5%, and 13% in mandibular central incisors and 20% in mandibular lateral incisors (p >0.05). There was no significant difference between gender and age. The intra and interexaminer agreement was fair (kappa intra=0.60; kappa inter=0.57). For the first part of this research, it is possible to conclude that the identification of the number of root canals was effective using all the methods. However, limitations were found in differentiating the shape of the root canal. As a conclusion of the second part of this research, the presence of 2 root canals in mandibular incisors of Bauru region patients is approximately 20% and it does not depend on tooth location or patients gender and age.
14

Estudo clínico randomizado e controlado de implantes de diâmetro reduzido confeccionados em titânio puro e uma liga de titânio/zircônico instalados em área de molares inferiores: resultados de 1 ano de acompanhamento / One-year follow up of titanium/zirconium alloy X commercially pure titanium narrow-diameter implants placed in the molar region of the mandible: a randomized controlled trial

Lívia de Souza Tolentino 17 November 2014 (has links)
O objetivo do presente estudo clínico randomizado e controlado foi de avaliar e comparar o nível ósseo marginal (NOM) ao redor de implantes de diâmetro reduzido (IDRs - 3,3 mm) confeccionados em uma liga de titânio/zircônio e titânio puro instalados em regiões de molares inferiores após um ano das próteses estarem em função. Dez pacientes participaram do estudo. Em cada paciente um IDR de titânio com adição de zircônio (TiZr; Grupo Teste) e um IDR de titânio puro (Ti; Grupo Controle) foram instalados de forma randomizada em áreas contralaterais de molares inferiores. Após 8 semanas de cicatrização, as próteses metalocerâmicas foram instaladas e os pacientes foram incluídos em um programa de controle de placa bacteriana. Radiografias periapicais foram utilizadas para avaliar o NOM nas faces mesial e distal dos implantes. Essas medidas foram realizadas imediatamente após a instalação das próteses (T1) e um ano após as próteses estarem em função (T2). Além disso, profundidade clínica de sondagem, sangramento à sondagem, supuração, placa bacteriana visível, e mobilidade do implante foram avaliados para a determinação das taxas de sucesso e sobrevivência do implante. Após 1 ano de acompanhamento, a média da mudança do nível ósseo periimplantar marginal nas faces interproximais foi de 0,32±0,27 e 0,35±0,24 mm nos sítios do Grupo Teste e Controle, respectivamente (p> 0,05). Não houve diferença estatisticamente significativa entre os grupos. Além disso, não houve falhas nos implantes neste período de acompanhamento e os valores médios das variáveis clínicas estudas também foram similares entre os grupos (p> 0,05). Desta forma, este trabalho sugere que IDRs feitos da liga titânio/zircônio ou de titânio puro, podem ser igualmente usados para suportar coroas unitárias em regiões posteriores da mandíbula. / The aim of the present randomized controlled trial study was to analyze marginal bone loss (MBL) and clinical parameters around narrow-diameter implants (NDIs - 3.3 mm) made of titanium/zirconium alloy (TiZr) in comparison to commercially pure titanium (cpTi) installed in the molar region of the mandible after one year in function. Ten patients participated in the study. A TiZr and a cpTi NDI were randomly installed in contralateral molar sites of the mandible of each patient in a split-mouth design. Eight weeks after healing, all metal-ceramic single crowns were adapted to the implants and patients were enrolled in a plaque control program. MBL at the mesial and distal aspects of the implants were evaluated by comparing periapical radiographs taken immediately after prosthesis installation (T1) and one year after loading (T2). Clinical probing depth, bleeding on probing, suppuration, visible plaque, and implant mobility were evaluated to determine implant success and survival rates. Mean MBL at the interproximal aspects of TiZr implant sites was 0.32±0.27 mm, while at cpTi implant sites MBL was 0.35±0.24 mm (p> 0.05). Both TiZr and cpTi NDIs presented 100% implant survival and success rates, with no significant differences in the clinical parameters studied (p> 0.05). In conclusion, TiZr and cpTi NDIs presented similar outcomes after one year in function in the molar region of the mandible. The results suggest that TiZr and cpTi NDIs may be equally used to support single crowns in the posterior area of the mouth. However, further studies with longer follow-up periods are necessary to confirm these findings.
15

Tomografia computadorizada por feixe cônico para identificação de defeitos ósseos peri-implantares quimicamente simulados em costelas bovinas frescas / Cone beam computed tomography for identification of peri-implant bone loss chemically simulated in fresh bovine ribs

Lucas Rodrigues Pinheiro 12 March 2015 (has links)
O objetivo deste estudo foi avaliar a acurácia, sensibilidade, especificidade e concordância inter e intra-observador dos exames radiográficos: radiografia periapical digital indireta (RP) por meio de placas de fósforo e tomografia computadorizada por feixe cônico (TCFC) na detecção de defeitos ósseos peri-implantares quimicamente simulados com Ácido Perclórico a 70%. 80 implantes foram instalados em blocos de costela bovina. Os implantes foram divididos em 2 grupos (grupo controle e grupo teste), em seguida o grupo teste foi dividido em 2 subgrupos (G1 e G2). O grupo G1 foi exposto a 4h de ácido causando defeitos de aproximadamente 3-4 mm de profundidade e largura <=1 mm, enquanto o grupo G2 foi exposto a 12h . Posteriormente, as amostras foram submetidas a um sistema de Radiografia digital indireta por meio de placa de fósforo (CS 7600) e a dois diferentes tomógrafos, utilizando variados protocolos (iCAT Next Generation e 3D Accuitomo 170). Os observadores avaliaram as imagens em um programa de visualização independente (OsiriX MD) utilizando a ferramenta a 3D-RMP que permite explorar cortes axiais, coronais, sagitais, parassagitais e circunferenciais simultaneamente. Nas amostras avaliadas por radiografia periapical, os valores da ASC encontrados nas amostras com defeitos ósseo menores variaram entre 0,442 a 0,534; no iCAT Next Generantion, variaram entre 0,645 a 0.828 em dois protocolos diferente. No 3D Accuitomo 170, variaram entre 0.563 a 0.904, em protocolos diferentes. No grupo com defeito ósseos maiores os resultados foram superiores. Na radiografia periapical, os valores encontrados variaram entre 0,652 a 0,771; no iCAT Next Generation, variaram entre 0,708 a 0,946 em dois protocolos diferentes e no 3D Accuitomo 170, entre 0.628 a 0.962 em 4 protocolos diferentes. A radiografia periapical foi a modalidade testada que obteve pior desempenho, especialmente no grupo de lesões menores. O protocolo de 90 kVp, FOV 4x4 cm e 1009 projeções de raios-X do 3D Accuitomo 170 foi o que obteve os valores de diagnóstico mais altos. A TCFC obteve resultados mais satisfatórios que a RP para a detecção de defeitos ósseos peri-implantares. Porém o uso da TCFC deve ser cauteloso e criterioso na hora da escolha do protocolo de aquisição adequado para cada situação. / The aim of this study was to test the accuracy, sensitivity, specificity, inter and intra-observer and area AZ values of two radiographic examinations: digital periapical radiographs and cone beam computed tomography (CBCT) in the detection of two sizes of peri-implant bone defects chemically simulated with Perchloric Acid 70%. PR and CBCT were performed in 80 dental implants installed in blocks of bovine rib. An indirect digital radiography system using smart phosphor plates (CS 7600) and two different CBCT scanners, using different protocols (iCAT Next Generation 3D Accuitomo 170) were evaluated. Observers evaluated the images in a separate DICOM viewer (OsiriX MD) using the 3D-RMP tool. This tool allows the visualization of axial, coronal, sagittal, cross-section and circumferential images. In samples evaluated by periapical radiography, the AZ values found in the samples with smaller bone defects ranged from 0.442 to 0.534; in iCAT Next Generantion, ranged from 0.645 to 0.828 in two different protocols. In 3D Accuitomo 170, ranged 0.563-0.904 in four different protocols. In the group with larger bone defect results were superior. In periapical, the values found ranged from 0.652 to 0.771; iCAT the Next Generation ranged from 0.708 to 0.946 in two different protocols and 3D Accuitomo 170, 0.628-0.962 in 4 different protocols. Periapical radiographs were tested method that had a worse performance, especially in the smaller lesions group. The protocol FOV 4x4 cm and 1009 frames of 3D Accuitomo 170 had the highest diagnostic values. The CBCT proved to be a useful imaging modality for detecting the peri-implant bone defects, with better results than PR. But the use of CBCT should be cautious and careful when choosing the acquisition protocol appropriate for each situation.
16

Estudo clínico randomizado e controlado de implantes de diâmetro reduzido confeccionados em titânio puro e uma liga de titânio/zircônico instalados em área de molares inferiores: resultados de 1 ano de acompanhamento / One-year follow up of titanium/zirconium alloy X commercially pure titanium narrow-diameter implants placed in the molar region of the mandible: a randomized controlled trial

Tolentino, Lívia de Souza 17 November 2014 (has links)
O objetivo do presente estudo clínico randomizado e controlado foi de avaliar e comparar o nível ósseo marginal (NOM) ao redor de implantes de diâmetro reduzido (IDRs - 3,3 mm) confeccionados em uma liga de titânio/zircônio e titânio puro instalados em regiões de molares inferiores após um ano das próteses estarem em função. Dez pacientes participaram do estudo. Em cada paciente um IDR de titânio com adição de zircônio (TiZr; Grupo Teste) e um IDR de titânio puro (Ti; Grupo Controle) foram instalados de forma randomizada em áreas contralaterais de molares inferiores. Após 8 semanas de cicatrização, as próteses metalocerâmicas foram instaladas e os pacientes foram incluídos em um programa de controle de placa bacteriana. Radiografias periapicais foram utilizadas para avaliar o NOM nas faces mesial e distal dos implantes. Essas medidas foram realizadas imediatamente após a instalação das próteses (T1) e um ano após as próteses estarem em função (T2). Além disso, profundidade clínica de sondagem, sangramento à sondagem, supuração, placa bacteriana visível, e mobilidade do implante foram avaliados para a determinação das taxas de sucesso e sobrevivência do implante. Após 1 ano de acompanhamento, a média da mudança do nível ósseo periimplantar marginal nas faces interproximais foi de 0,32±0,27 e 0,35±0,24 mm nos sítios do Grupo Teste e Controle, respectivamente (p> 0,05). Não houve diferença estatisticamente significativa entre os grupos. Além disso, não houve falhas nos implantes neste período de acompanhamento e os valores médios das variáveis clínicas estudas também foram similares entre os grupos (p> 0,05). Desta forma, este trabalho sugere que IDRs feitos da liga titânio/zircônio ou de titânio puro, podem ser igualmente usados para suportar coroas unitárias em regiões posteriores da mandíbula. / The aim of the present randomized controlled trial study was to analyze marginal bone loss (MBL) and clinical parameters around narrow-diameter implants (NDIs - 3.3 mm) made of titanium/zirconium alloy (TiZr) in comparison to commercially pure titanium (cpTi) installed in the molar region of the mandible after one year in function. Ten patients participated in the study. A TiZr and a cpTi NDI were randomly installed in contralateral molar sites of the mandible of each patient in a split-mouth design. Eight weeks after healing, all metal-ceramic single crowns were adapted to the implants and patients were enrolled in a plaque control program. MBL at the mesial and distal aspects of the implants were evaluated by comparing periapical radiographs taken immediately after prosthesis installation (T1) and one year after loading (T2). Clinical probing depth, bleeding on probing, suppuration, visible plaque, and implant mobility were evaluated to determine implant success and survival rates. Mean MBL at the interproximal aspects of TiZr implant sites was 0.32±0.27 mm, while at cpTi implant sites MBL was 0.35±0.24 mm (p> 0.05). Both TiZr and cpTi NDIs presented 100% implant survival and success rates, with no significant differences in the clinical parameters studied (p> 0.05). In conclusion, TiZr and cpTi NDIs presented similar outcomes after one year in function in the molar region of the mandible. The results suggest that TiZr and cpTi NDIs may be equally used to support single crowns in the posterior area of the mouth. However, further studies with longer follow-up periods are necessary to confirm these findings.
17

Identificação de dois canais radiculares em incisivos inferiores com imagens radiográficas, tomográficas e microtomográficas / Identification of two root canals in mandibular incisors using radiographic, tomographic and microtomographic images

Luciana Maria Paes da Silva Ramos Fernandes 06 June 2014 (has links)
Os dentes incisivos inferiores apresentam, em sua maioria, canal radicular único, que pode ter conformações distintas. De acordo com a literatura científica, a presença de um segundo canal radicular pode ser constatada em 10 a 40% dos casos. A não-detecção do segundo canal é um importante fator para o insucesso do tratamento endodôntico. Esta pesquisa foi realizada com os seguintes objetivos: 1) comparar a eficácia na identificação de padrões anatômicos internos em incisivos inferiores permanentes extraídos com uso de imagem radiográfica periapical digital e de tomografia computadorizada de feixe cônico (TCFC); e 2) determinar a prevalência de 2 canais radiculares em incisivos inferiores em imagens de TCFC de um banco de dados de exames previamente realizados, associando com localização do dente, gênero e idade do paciente. Na primeira etapa da pesquisa, 40 dentes incisivos inferiores foram submetidos a escaneamento em microtomógrafo computadorizado da FOB-USP (Skyscan 1074) para estabelecer o padrão ouro do tipo anatômico interno de cada dente. Os dentes foram então classificados em: Tipo I (1 canal radicular regular, n=12), Tipo Ia (1 canal radicular oval, n=12) e Tipo III (2 canais radiculares, n=16). Em seguida, os dentes foram divididos em 10 grupos de 4 dentes e posicionados em alvéolos de uma mandíbula humana para exposição radiográfica periapical digital direta com duas tomadas variando o ângulo horizontal de incidência (Schick CDR) e para escaneamento em 3 tomógrafos (Kodak 9000 3D, Veraviewepocs 3De e NewTom 5G) da Universidade de Loma Linda, CA, EUA. Dois examinadores treinados classificaram o tipo anatômico de cada dente e suas respostas foram comparadas ao padrão ouro estabelecido por microtomografia. Para descrição dos resultados, utilizou-se a porcentagem (%) de respostas certas / erradas. Aplicou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%, para verificação da associação entre variáveis. As concordâncias inter e intraexaminador foram determinadas por teste de kappa. Na segunda etapa da pesquisa, foram interpretadas imagens de incisivos inferiores de 100 pacientes, cujos exames estavam disponíveis no banco de dados do tomógrafo i-CAT Classic da FOB-USP. Dois examinadores avaliaram a anatomia interna de incisivos inferiores, em reconstruções axiais, sagitais e coronais, classificando-a de acordo com o número de canais radiculares. A prevalência de 2 canais radiculares foi relacionada à localização do dente e ao gênero e idade do paciente. Para descrição dos dados coletados, utilizou-se a porcentagem (%). Para verificar a associação entre variáveis, utilizou-se o teste do qui-quadrado (X2), com nível de significância estatística de 5%. Para a concordância intra e interexaminador, utilizou-se o teste de kappa. Como resultado da primeira etapa da pesquisa, obteve-se alto índice de detecção de tipos anatômicos para todos os métodos avaliados (p <0,05). Para dentes com Tipo I (1 canal radicular regular), as imagens de TCFC foram superiores em comparação à radiografia periapical digital com dupla exposição (RP= 67% de acerto; TCFC= 98% de acerto, p <0,05). Considerando os 3 aparelhos de TCFC, não houve diferença estatística significante entre eles para identificação do Tipo I. Já para dentes com Tipo Ia (1 canal radicular oval), houve diferença estatística significante somente entre radiografia periapical digital com dupla exposição e o tomógrafo NewTom (RP= 44% de acerto; TCFC NewTom= 88% de acerto). Não houve diferença significante entre os outros 2 tomógrafos e radiografia periapical ou entre os 3 tomógrafos. Considerando dentes com Tipo III (2 canais radiculares), não houve diferença estatística significante entre nenhum dos métodos. Todos os métodos apresentaram números de respostas certas semelhantes para o Tipo III, sugerindo que a radiografia periapical com dupla angulação é suficiente para identificação de 2 canais radiculares em incisivos inferiores. A concordância intraexaminador para radiografia periapical foi regular (kappa=0,40 a 0,66) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,85). A concordância interexaminador para radiografia periapical foi de ruim a regular (kappa=0,25 a 0,32) e de boa a excelente para os aparelhos de TCFC (kappa=0,62 a 0,92). Na segunda etapa da pesquisa, o total de 386 incisivos inferiores foi avaliado, sendo 192 incisivos centrais e 194 incisivos laterais. A prevalência de 2 canais radiculares constatada no total de dentes foi de 16,5%, sendo de 13% em incisivos centrais e de 20% nos incisivos laterais (p >0,05). Não houve diferença estatisticamente significante entre gêneros e idades. A concordância intra e interexaminador foi regular (kappa intra=0,60; kappa inter=0,57). Como conclusão da primeira etapa da pesquisa, observou-se que a identificação do número de canais radiculares foi efetiva em todos os métodos. No entanto, limitações foram encontradas para a diferenciação da forma do canal radicular. Na segunda etapa da pesquisa, concluiuse que a presença de 2 canais radiculares em incisivos inferiores de pacientes da região de Bauru é de aproximadamente 20% e não depende da localização do dente ou de gênero e idade do paciente. / Mandibular incisors most commonly have a single root canal, which can present with different anatomic configurations. According to the literature, the presence of a second root canal can be observed in 10 - 40% of the teeth. Difficulty in detecting the second root canal is an important factor for the endodontic treatment failure. The aim of this research was: 1) to compare the efficacy of digital periapical radiography (PA) with double exposure and cone beam computed tomography (CBCT) in the identification of internal anatomic patterns in mandibular incisors, and 2) to determine the prevalence of 2 root canals in mandibular incisors using cone beam computed tomographic images of a patient database, comparing to tooth position and patients gender and age. In the first part of this research, 40 extracted mandibular incisors underwent microcomputed tomographic (micro-CT) scanning (Skyscan 1074) in order to establish the gold standard for internal anatomic pattern. The teeth were classified according to: Type I (1 regular root canal, n=12), Type Ia (1 oval root canal, n=12), and Type III (2 root canals, n=16). Then, the teeth were divided into 10 groups of 4 teeth and placed in a preserved human mandible for direct digital periapical radiographic double exposure (Schick CDR) and CBCT scans using Kodak 9000 3D, Veraviewepocs 3De and NewTom 5G. Two blinded examiners classified the anatomic pattern of each tooth and their answers were compared to the gold standard (microtomographic images). Percentage (%) of right / wrong answers was used for the statistical analysis of the results. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. In the second part of this research, CBCT images of a 100 patients database from FOB-USP were examined. Two examiners assessed the internal anatomy of mandibular incisors in axial, sagittal and coronal reconstructions and classified the teeth according to the number of root canals. The prevalence of 2 root canals was related to the tooth location and patients gender and age. Percentage (%) was used to describe the collected data. Chi-square test (X2) was used to verify the association between variables (p <.05). Inter and intraexaminer agreements were determined using kappa values. The results of the first part of the research showed a high level of identification of anatomic patterns for all the methods (p <0.05). Considering Type I (1 regular root canal), CBCT images were better in comparison to PA (PA= 67%; CBCT= 98%, p <0.05). There was no significant difference between the 3 CBCT scanners. For Type Ia (1 oval root canal), there was a significant difference between PA and CBCT imaging using the NewTom unit only (PA= 44%, NewTom CBCT= 88%). No significant differences were found between the other 2 CBCT units and PA or between the 3 CBCT units. Considering Type III (2 root canals), there was no significant difference between the various methods. All the methods presented similar corrected answers index for Type III, which may suggest that PA with double exposure is sufficient for the identification of 2 root canals in mandibular incisors. The intraexaminer agreement was fair for PA (kappa=0.40 to 0.66) and good to very good for the CBCT units (kappa=0.62 to 0.85). The interexaminer agreement was poor to fair for PA (kappa=0.25 to 0.32) and good to very good for CBCT units (kappa=0.62 to 0.92). In the second part of this research, the total amount of 386 mandibular incisors was assessed in CBCT images (192 mandibular central incisors and 194 mandibular lateral incisors). The overall prevalence of 2 root canals was 16.5%, and 13% in mandibular central incisors and 20% in mandibular lateral incisors (p >0.05). There was no significant difference between gender and age. The intra and interexaminer agreement was fair (kappa intra=0.60; kappa inter=0.57). For the first part of this research, it is possible to conclude that the identification of the number of root canals was effective using all the methods. However, limitations were found in differentiating the shape of the root canal. As a conclusion of the second part of this research, the presence of 2 root canals in mandibular incisors of Bauru region patients is approximately 20% and it does not depend on tooth location or patients gender and age.

Page generated in 0.0723 seconds