• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 15
  • 2
  • 2
  • 1
  • Tagged with
  • 36
  • 36
  • 26
  • 16
  • 16
  • 15
  • 13
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • 9
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Effect of JPEG2000 compression on landmark identification of lateral cephalometric digital radiographs a thesis /

Abdelkarim, Ahmad Ali. January 2008 (has links)
Thesis (M.S.) --University of Texas Graduate School of Biomedical Sciences at San Antonio, 2008. / Vita. Includes bibliographical references.
2

Radiation dose and image quality in diagnostic radiology : optimization of the dose - image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector /

Geijer, Håkan, January 2001 (has links)
Diss. (sammanfattning) Linköping : Univ., 2001. / Härtill 5 uppsatser.
3

Quantifying image quality in diagnostic radiology using simulation of the imaging system and model observers /

Ullman, Gustaf, January 2008 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2008. / Härtill 6 uppsatser. Includes bibliographical references.
4

Quantifying image quality in diagnostic radiology using simulation of the imaging system and model observers /

Ullman, Gustaf, January 2008 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2008. / Härtill 6 uppsatser.
5

Visual linearization of image data for the display of digital intraoral radiographs /

Li, Gang, January 2004 (has links)
Diss. (sammanfattning) Stockholm : Karol. inst., 2004. / Härtill 6 uppsatser.
6

Effect of slit scan imaging techniques on image quality on radiotherapy electronic portal imaging

Walton, Dean R. January 2008 (has links)
Thesis (M.S.)--University of Toledo, 2008. / "In partial fulfillment of the requirements for the degree of Master of Science in Biomedical Sciences." Title from title page of PDF document. Bibliography: pages 67-72.
7

An in-vitro comparison of working length determination between a digital system and conventional film when source-film/sensor distance and exposure time are modified

Ley, Paul J. January 2009 (has links)
Thesis (M.S.D.)--Indiana University School of Dentistry, 2009. / Title from PDF t.p. (viewed Aug. 11, 2009) Advisors: Mychel Vail, Chair of the Research Committee, Susan Zunt, Ted Parks, Kenneth Sponik, Joseph Legan. Curriculum vitae. Includes abstract. Includes bibliographical references (leaves 103-119).
8

Avaliação da interface osso e implantes dentários em exames por imagem e suas implicações no diagnóstico

Vidor, Michele Machado January 2015 (has links)
Introdução: O desenvolvimento da radiologia digital e da tomografia computadorizada de feixe cônico (TCFC) permitiu aos profissionais diferentes formas de avaliação das imagens. Entretanto, frente a materiais metálicos, é observada a formação de artefatos tanto na imagem tomográfica, quanto nas radiografias digitais após a aplicação de filtros de processamento. Objetivo: Esta pesquisa objetivou investigar a interferência provocada por materiais metálicos na avaliação da interface osso/implante em radiografias periapicais convencional e digital, e em TCFC. Materiais e Métodos: Foram inseridos implantes de titânio em 74 blocos de costelas bovina frescas. Em 37, a inserção foi em íntima relação com as paredes ósseas (Grupo Controle-GC) e nos outros 37 com um espaço de 0.125 mm (Grupo Teste-GT). As radiografias periapicais foram realizadas com filme convencional e dois sistemas digitais de placa de fósforo. As imagens volumétricas foram adquiridas em dois equipamentos de TCFC. Nos sistemas digitais as imagens foram investigadas com e sem a utilização dos filtros e, nas tomografias, com diferentes protocolos de aquisição. Três examinadores treinados e cegados realizaram a avaliação utilizando uma escala Likert de cinco pontos. Foram utilizados testes de sensibilidade, especificidade e acurácia (área sob a curva ROC) e teste de concordância de Kendall (W). Resultados: Na avaliação radiográfica (ARTIGO I), foi observada maior acurácia do exame convencional e das imagens do sistema VistaScan com filtros Caries2 e Endo e do sistema Express com filtro Sharpen3 na detecção da justaposição entre osso e implante. Na avaliação tomográfica (ARTIGO II), somente as imagens do tomógrafo i-Cat com a resolução de voxel de 0.125mm não apresentaram diferença significativa com a radiografia convencional na acurácia diagnóstica. Conclusão: Na avaliação radiográfica da justaposição entre o osso e o implante, preferência deve ser dada às radiografias convencionais ou às digitais com filtros de realce (Caries2, Endo e Sharpen3). Em caso da existência de exames de TCFC com voxel 0.125 mm, tal avaliação também pode ser realizada. / Introduction: The development of digital radiology and computed tomography cone beam (CBCT) enabled professionals different possibilities of images evaluation. However, when metallic materials are present, artifacts formation can be observed in tomographic images and in digital radiography after processing fiters. Objective: This study investigated the interference caused by metallic materials in bone/implant interface evaluation with conventional and digital periapical radiographs, and CBCT. Materials and Methods: Titanium implants were placed into 74 fresh bovine ribs. In 37, the implants were in close relation with the bone walls (Control Group-CG) and the remaining 37 ribs preparations promoted a 0.125 mm space (Test Group-GT) .The periapical radiographs were taken with conventional film and digital photostimulable phosphor plate (PSP) system of two commercial brands. The volumetric images were acquired in two CBCT equipment. The digital images were investigated with and without the use of processing filters available and the tomographic with different acquisition protocol. Three trained and blinded examiners performed the evaluation using a five points Likert scale. Sensitivity, specificity and accuracy (area under the ROC curve) tests were used and Kendall´s coefficient of concordance (W). Results: In the radiographic evaluation (Article I), there was a higher accuracy to detect the juxtaposition between bone and implant with the conventional radiography and the images of VistaScan system using the Caries2 and Endo filters, and Express system with Sharpen3 filter. In the tomographic evaluation (Article II), only the images with 0.125mm of voxel resolution from i-Cat CBCT showed no significant difference with conventional radiography in the diagnostic accuracy. Conclusion: In radiographic evaluation of juxtaposition between bone and implant preference should be given to conventional radiographs or in digital radiographs to Caries2, Endo and Sharpen3 enhancement filters. In case of the existence of CBCT exams (voxel 0.125mm), such evaluation can also be performed.
9

Avaliação da influência dos formatos DICOM e JPEG na reprodutibilidade de pontos cefalométricos em Telerradiografia digital em Norma Frontal / Evaluation of influence of DICOM and JPEG formats in the reproducibility of cephalometric landmarks in digital Frontal Teleradiographies

Saez, Daniel Martinez 31 March 2009 (has links)
Made available in DSpace on 2016-08-03T16:31:14Z (GMT). No. of bitstreams: 1 DANIEL MARTINEZ SAEZ.pdf: 1606570 bytes, checksum: c2773e8408583cb2ada8e4b43508558e (MD5) Previous issue date: 2009-03-31 / The digital image on DICOM format request a large store size capability, making difficult the transmission through internet, usually requesting the image compression via JPEG file format. The aim of this study was to evaluate the influence of DICOM and JPEG file formats on Quality Factors 100, 80 and 60, in the reproducibility intra and interexaminer at cephalometrics landmarks identification at digital Frontal Teleradiographies. The sample consists of 120 digital images of Frontal Teleradiographies, obtained from 30 individuals. The 30 original images in DICOM format was converted into a JPEG format on Quality Factors 100, 80 and 60. After blind and random the sample, three calibrated orthodontist marked 18 cephalometric points on each image using a computerized cephalometric program which has in account cephametric points values in a X and Y cartesians coordinates system. At the results, the statistical tests at intraclasses correlations and variant analysis (ANOVA) presents a reproducibility agreement of the cephalometric points on digital Frontal Teleradiographies on intra such as interexaminer, except for points ZL, ZR, AZ, JR, NC, CN on coordinate Y and A6 on coordinate X, independently of file formats. As a conclusion, the file formats DICOM and JPEG on Quality Factors 100, 80 and 60 do not affected the reproducibility intra and interexaminers on a cephalometric landmarks identification.(AU) / A imagem digital no formato DICOM requer grande espaço para armazenamento, dificultando o arquivamento e transmissão da imagem via internet, sendo necessária, muitas vezes, a compressão das imagens por meio de formatos de arquivo como o JPEG. O objetivo neste estudo foi avaliar a influência dos formatos DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, na reprodutibilidade intra e interexaminador na marcação de pontos cefalométricos em Telerradiografias digitais em Norma Frontal. A amostra consistiu de 120 imagens digitais de Telerradiografias em Norma Frontal, obtidas de 30 indivíduos. As 30 imagens originais, em formato DICOM, posteriormente, foram convertidas para o formato JPEG, nos Fatores de Qualidade 100, 80 e 60. Após cegar e randomizar a amostra, três ortodontistas calibrados marcaram os 18 pontos cefalométricos em cada imagem utilizando um programa de cefalometria computadorizada, que registra as medidas dos pontos cefalométricos em um sistema de coordenadas cartesianas X e Y. Nos resultados, os testes estatísticos de correlações intraclasses e análise de variância (ANOVA) apresentaram concordância de reprodutibilidade dos pontos cefalométricos em Telerradiografias digitais em Norma Frontal, tanto intra como interexaminador, com exceção dos pontos ZL, ZR, AZ, JR, NC, CN na coordenada Y e A6 na coordenada X, independentemente dos formatos de arquivo. Em conclusão, os formatos de arquivo DICOM e JPEG, nos Fatores de Qualidade 100, 80 e 60, não afetaram a reprodutibilidade intra e interexaminador na marcação dos pontos cefalométricos.(AU)
10

Estudo da viabilidade do emprego da técnica de subtração radiográfica digital em radiografias periapicais com registro a posteriori

Assis, Afonso Celso Souza de [UNESP] 31 May 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-05-31Bitstream added on 2014-06-13T19:26:45Z : No. of bitstreams: 1 assis_acs_me_sjc.pdf: 596243 bytes, checksum: fb9783652a81f3cb2ec3e7e3c9337fbc (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Apesar de ser uma técnica limitada, a subtração digital é utilizada na Odontologia. A adição do computador e seus algoritmos para equalização de contraste e também correção geométrica, tornou possível a aplicação da subtração radiográfica digital (SRD), utilizando radiografias intrabucais. Neste estudo foi avaliada a viabilidade da utilização da subtração radiográfica digital pelo programa Regeemy – Image Registration and Mosaicking v.0.2.43-RCB (DPI-INPE, São José dos Campos, SP, Brazil) em radiografias periapicais digitalizadas e obtidas sem utilização de padronização rígida durante as exposições por meio de registro a posteriori. A seleção dos pontos de controle foram realizadas de forma automática e em quantidade múltipla pelo Reggemy. Esses pontos serviram como coordenadas a partir das quais o programa alinhou o par de imagens e gerou uma terceira imagem de acordo com a projeção geométrica da imagem de referência. Com o uso do Adobe Photoshop© foram selecionados os ROI das imagens utilizando guias e coordenadas. Depois de aplicados os testes estatísticos foi verificado que a metodologia do presente estudo não permite concluir que a subtração utilizando-se o programa Regeemy é inviável quando realizada sem padronização / The digital subtraction has been widely used in dentistry. The addition of computer and its algorithms for equalization of contrast and geometric correction also made possible the application of radiographic digital subtraction (SRD) using intraoral radiographs. This study assessed the feasibility of using X-ray digital subtraction of the program Regeemy - Image Registration and mosaicking v.0.2.43-RCB (DPI-INPE, Sao Jose dos Campos, SP, Brazil) in periapical radiographs digitized and obtained without the use of standardized rigid during the exposures by registering the event. The selection of control points were performed automatically and in quantity by multiple Reggemy. These points were used as coordinates from which the program aligned the image pair and a third image generated according to the geometrical projection of the reference image. Using Adobe Photoshop ©, we selected the ROI of the images using guides and coordinates. After applying the statistical tests we can conclude that the methodology of this study does not suggest that the subtraction using the program Regeemy is feasible when performed without standardization. It is suggested further studies to evaluate the impact of subtraction radiography with no standardization in clinical diagnosis

Page generated in 0.1144 seconds