121

Evaluación de la coincidencia entre el isocentro de la imagen de simulación y verificación, en el tratamiento con radioterapia del cáncer de cuello uterino : Instituto Nacional de Enfermedades Neoplásicas enero - diciembre 2013

Navarro Mejía, Estrellita de los Milagros January 2014 (has links)
Se realizó un estudio de diseño descriptivo, de tipo observacional, retrospectivo y de corte transversal, con el objetivo de evaluar la coincidencia del isocentro entre la imagen de simulación y la imagen de verificación, en el tratamiento con radioterapia del cáncer de cuello uterino. Se seleccionó de manera no probabilística y por conveniencia 120 casos, de pacientes con cáncer de cuello uterino, que consiste en 120 imágenes radiográficas en proyección antero-posterior y 120 en proyección lateral, realizadas en el Departamento de Radioterapia del Instituto Nacional de Enfermedades Neoplásicas. Se analizó las imágenes radiográficas (verificadoras) una por una, observando y anotando en la ficha de recolección de datos, el valor de las variaciones hechas por los médicos radioncólogos., según los ejes espaciales X, Y y Z a su vez éstas tienen subdivisiones; derecha-izquierda, superior-inferior, anterior-posterior, respectivamente. Los datos fueron procesados y analizados utilizando el programa SPSS versión 19.0. Los resultados mostraron que en un 64.2% del total de casos analizados, sí hubo variación del isocentro entre la imagen de simulación y la de verificación, solo un 35.8% el isocentro de ambas imágenes coinciden. El promedio de variación de los tres ejes (X, Y y Z) es de 0,5cm este valor esta dentro del margen contemplado por la International Commission on Radiation Units and Radiation Units and Measurements (ICRU) Reporte 29. Sin embargo, no podemos acreditar que todo el tiempo de tratamiento, este promedio se conserve, ya que solo se toma una imagen verificadora, antes de iniciar el tratamiento. La paciente durante su tratamiento puede tener cambios físicos, como bajar de peso, es por ello que recomendamos que la toma de imágenes verificadoras sea mínimo 1 vez por semana. El fin de la radioterapia no solo es eliminar el tumor sino también proteger los órganos y tejidos adyacentes, para esto el tecnólogo médico en radioterapia debe estar capacitado y con la disposición de posicionar con exactitud a la paciente, estando siempre atento a los cambios físicos que puedan tener. Los dispositivos de inmovilización cumplen un rol fundamental con ellos nos aseguramos de que la paciente, no se mueva y siempre tenga la misma posición durante todo el tratamiento, estos dispositivos deben ser mejorados e implementados por igual en las tres salas de tratamiento así como en la de simulación, deben ser los mismos. Conclusión: En este estudio se encontró poca coincidencia del isocentro entre la imagen de simulación y verificación, con un promedio de variación en los ejes X, Y y Z mayor a los reportados en la literatura, pero dentro del margen aceptado internacionalmente. Debe prestarse especial atención en las pacientes obesas las cuales posiblemente requieran una mejor técnica de inmovilización. / Tesis
122

Efeito protetor do a-Tocoferol (vitamina E) na estomatite radioinduzida : um ensaio clínico randomizado e duplo-cego

Ferreira, Paulo Renato Figueiredo January 2000 (has links)
Resumo não disponível
123

Utilização da dosimetria opticamente estimulada (OSL) na avaliação de parâmetros de qualidade de feixe em radioterapia / Utilization of optically stimulated dosimetry (OSL) to evaluate beam parameters of quality in radiotherapy

Giglioti, Roberta 15 June 2010 (has links)
O controle de qualidade do feixe é fundamental para garantir os requisitos mínimos de operação aos serviços de radioterapia, visto que a avaliação de parâmetros como simetria, planura, penumbra, fatores filtro e bandeja além de outros parâmetros dosimétricos é imprescindível para garantir constância aos tratamentos radioterápicos minimizando erros na entrega da dose. A avaliação destes parâmetros em radioterapia normalmente é realizada através de câmaras de ionização, filmes radiográficos ou detectores semicondutores sendo eles diodos e MOSFETs. Nos últimos anos o crescimento da utilização da dosimetria opticamente estimulada (OSL) na dosimetria individual externa em diversos países da Europa, USA e America latina como México e Peru proporcionou a aplicação de detectores OSL também na dosimetria em radioterapia visando à avaliação de parâmetros de feixe. A técnica de OSL une características técnicas encontradas em filmes e TLD, acrescidas de novas propriedades não possíveis nas tecnologias utilizadas anteriormente, por exemplo: possibilidade de re-leitura do dosímetro, integração de dose com avaliação de doses intermediárias entre exposições no mesmo dosímetro e simplicidade no processo de leitura. Recentemente a Landauer Inc lançou no mercado americano fitas dosimétricas de OSL para a análise do perfil de dose em Tomografia Computadorizada (TC). Neste trabalho foi avaliada a utilização deste detector OSL em forma de fita, na determinação de parâmetros de qualidade em radioterapia tais como simetria e planura, fatores filtro e bandeja, porcentagem e dose profunda (PDP) e penumbra. Os resultados obtidos permitem concluir que o detector estudado se apresenta eficaz na determinação dos parâmetros de qualidade, porém a metodologia de análise de dados bem como o setup utilizado na irradiação inicial devem ser reformulados buscando obter resultados mais precisos de forma a validar a utilização deste método na rotina de trabalho em radioterapia. / Beam´s quality control is fundamental to ensure minimum operation requirements to radiotherapy services, since parameters evaluation, such as symmetry, planura, shade, filter factors and tray, amongst other ones, is necessary to guarantee stability to radiotherapy treatments, which minimize errors at dose delivery. The evaluation of those parameters in radiotherapy is normally executed through ionization compartments, radiographic films or semiconductor detectors, specifically diode and MOSFETs. Through the last years, the utilization of optically stimulated dosimetry at external individual dosimetry increased in several Europe countries, USA and Latin America countries, such as Mexico and Peru, which made it possible to apply OSL detectors at dosimetry to radiotherapy as well, in order to evaluate clusters parameters of quality. The OSL technique incorporate technical characteristics, found in films and TLD, to new proprieties, which were not available at preceding technologies, such as: possibility of dosimetry rereading, dose integration with intermediary doses evaluation between exposure at the same dosimeter and simplicity at the reading process. Recently, Launder Inc launched in the American market OSL dosimetric ribbons to dose profile analysis in computed tomography (TC). In this paper, it was analyzed this OSL tape shaped detector utilization, in order to determine parameters of quality in radiotherapy, such as symmetry and beam flatness, filter factors and tray, depth dose percentage and dose and shade. The results allowed to conclude that the studied detector is effective to determine parameters of quality. However, analysis methodology, as well as the used setup at initial irradiation, must be reformulated in order to get more accurate results, which it will allow to validate this method utilization at daily work routine in radiotherapy.
124

Efeito protetor do a-Tocoferol (vitamina E) na estomatite radioinduzida : um ensaio clínico randomizado e duplo-cego

Ferreira, Paulo Renato Figueiredo January 2000 (has links)
Resumo não disponível
125

Efeito protetor do a-Tocoferol (vitamina E) na estomatite radioinduzida : um ensaio clínico randomizado e duplo-cego

Ferreira, Paulo Renato Figueiredo January 2000 (has links)
Resumo não disponível
126

Utilização da dosimetria opticamente estimulada (OSL) na avaliação de parâmetros de qualidade de feixe em radioterapia / Utilization of optically stimulated dosimetry (OSL) to evaluate beam parameters of quality in radiotherapy

Roberta Giglioti 15 June 2010 (has links)
O controle de qualidade do feixe é fundamental para garantir os requisitos mínimos de operação aos serviços de radioterapia, visto que a avaliação de parâmetros como simetria, planura, penumbra, fatores filtro e bandeja além de outros parâmetros dosimétricos é imprescindível para garantir constância aos tratamentos radioterápicos minimizando erros na entrega da dose. A avaliação destes parâmetros em radioterapia normalmente é realizada através de câmaras de ionização, filmes radiográficos ou detectores semicondutores sendo eles diodos e MOSFETs. Nos últimos anos o crescimento da utilização da dosimetria opticamente estimulada (OSL) na dosimetria individual externa em diversos países da Europa, USA e America latina como México e Peru proporcionou a aplicação de detectores OSL também na dosimetria em radioterapia visando à avaliação de parâmetros de feixe. A técnica de OSL une características técnicas encontradas em filmes e TLD, acrescidas de novas propriedades não possíveis nas tecnologias utilizadas anteriormente, por exemplo: possibilidade de re-leitura do dosímetro, integração de dose com avaliação de doses intermediárias entre exposições no mesmo dosímetro e simplicidade no processo de leitura. Recentemente a Landauer Inc lançou no mercado americano fitas dosimétricas de OSL para a análise do perfil de dose em Tomografia Computadorizada (TC). Neste trabalho foi avaliada a utilização deste detector OSL em forma de fita, na determinação de parâmetros de qualidade em radioterapia tais como simetria e planura, fatores filtro e bandeja, porcentagem e dose profunda (PDP) e penumbra. Os resultados obtidos permitem concluir que o detector estudado se apresenta eficaz na determinação dos parâmetros de qualidade, porém a metodologia de análise de dados bem como o setup utilizado na irradiação inicial devem ser reformulados buscando obter resultados mais precisos de forma a validar a utilização deste método na rotina de trabalho em radioterapia. / Beam´s quality control is fundamental to ensure minimum operation requirements to radiotherapy services, since parameters evaluation, such as symmetry, planura, shade, filter factors and tray, amongst other ones, is necessary to guarantee stability to radiotherapy treatments, which minimize errors at dose delivery. The evaluation of those parameters in radiotherapy is normally executed through ionization compartments, radiographic films or semiconductor detectors, specifically diode and MOSFETs. Through the last years, the utilization of optically stimulated dosimetry at external individual dosimetry increased in several Europe countries, USA and Latin America countries, such as Mexico and Peru, which made it possible to apply OSL detectors at dosimetry to radiotherapy as well, in order to evaluate clusters parameters of quality. The OSL technique incorporate technical characteristics, found in films and TLD, to new proprieties, which were not available at preceding technologies, such as: possibility of dosimetry rereading, dose integration with intermediary doses evaluation between exposure at the same dosimeter and simplicity at the reading process. Recently, Launder Inc launched in the American market OSL dosimetric ribbons to dose profile analysis in computed tomography (TC). In this paper, it was analyzed this OSL tape shaped detector utilization, in order to determine parameters of quality in radiotherapy, such as symmetry and beam flatness, filter factors and tray, depth dose percentage and dose and shade. The results allowed to conclude that the studied detector is effective to determine parameters of quality. However, analysis methodology, as well as the used setup at initial irradiation, must be reformulated in order to get more accurate results, which it will allow to validate this method utilization at daily work routine in radiotherapy.
127

Estudo e desenvolvimento de um modelo de análise de risco para Radiocirurgia intracraniana / Study and development of a risk analysis model to radiosurgery

Flávia Cristina da Silva Teixeira 17 August 2015 (has links)
Mundialmente, eventos relatados constituídos por incidentes e acidentes em radioterapia, tem aumentado ao longo dos últimos 25 anos e a maioria destes eventos são resultados de falha humana, além de terem ocorrido com maior frequência em centros sofisticados que utilizam alta tecnologia. Em radioterapia a Gestão da Qualidade necessita de uma abordagem prospectiva através de análise de risco. Esta abordagem é defendida por recentes publicações por ser atualmente uma urgência em virtude do expressivo número de acidentes ocorridos. Dada a complexidade do processo em radioterapia, a busca pela qualidade do tratamento de forma a garantir a segurança do paciente é um dos assuntos mais discutidos mundialmente. Embora apenas 14% dos centros de radioterapia no Brasil ofereçam tratamentos com a técnica de radiocirurgia intracranial (SRS), estudos relativos a qualidade do tratamento relacionada a segurança do paciente submetido à esta técnica, é de relevante importância, pois qualquer desvio da dose prescrita é considerado muito mais crítico que em outras modalidades de tratamento radioterápico, já que são utilizadas altas doses de radiação que em geral variam de 10 Gy a 40 Gy para lesões até 50 mm de diâmetro, que são aplicadas em uma única fração ou até cinco frações. Tendo em vista tais conhecimentos, o objetivo deste trabalho foi atender um novo paradigma de Gestão da Qualidade, através do desenvolvimento de um modelo de análise de risco e de um Índice de Qualidade para a SRS no Brasil, a partir da técnica de Mapa do Processo e FMEA utilizadas pelo TG 100/AAPM. O trabalho foi desenvolvido em três centros de radioterapia de referência em alta tecnologia, dois localizados no Rio de Janeiro e um em São Paulo. Um Mapa do Processo de SRS foi identificado em cada centro de radioterapia e em seguida foi aplicada a técnica FMEA para todos os subprocessos identificados no mapa. A partir dos valores de NPR obtidos pela FMEA foi realizado um ranqueamento dos modos de falha. Modos de falha com NPR ≥ 100 e S ≥ 7 foram escolhidos como prioridade para implementação de estratégias de segurança. A partir das pontuações do parâmetro S atribuídas na aplicação da FMEA foi criado o Índice de Severidade (IS) e um Índice de Qualidade (IQ) foi criado a partir de uma relação entre o NPR e o IS. O resultado deste estudo, indica que as estratégias de segurança sejam implementadas para os 10 primeiros modos de falha do ranking e uma reavaliação do processo deve ocorrer a cada 1 ano. É também indicado que o IQ obtenha uma melhora mínima de 9% após a reavaliação do processo. De forma geral, o estudo mostrou que a adoção da ferramenta FMEA juntamente com o IQ são de fato justificadas, por minimizar os riscos para o paciente, melhorando a qualidade do tratamento aprimorando a segurança, criando mecanismos que permitam a garantia de que a dose será entregue de forma precisa e exata, e consequentemente, aumentando as chances de cura ou do controle local com uma desejada qualidade de vida para estes pacientes. / The reported events in radiotherapy that constitute accidents or incidents have increased worldwide in the last 25 years. Most of these events resulted from human failure and have happened in radiotherapy centers that use high technologies. The radiotherapy Quality Management needs a prospective approach through risk analysis. This approach is supported by recent publications as this actually extremely needed due the large number of accidents. Because of the complexity of the process in radiotherapy, the search for quality of care in order to ensure patient safety is one of the most discussed topics worldwide. Although only 14% of radiotherapy centers in Brazil offer treatments with intracranial radiosurgery technique (SRS), studies about the quality of care related to the safety of patients undergoing this technique is of great importance. Any deviations from the prescribed dose using SRS technique is considered more critical than in other methods of radiation treatment, as the delivered doses in SRS are higher, in the range of 10 Gy to 40 Gy, to lesions up to 50 mm in diameter, which are delivered in a single fraction or in five fractions. In view of those information, this work aims to satisfy the new Quality Management paradigm by developing a risk analysis model, and a Quality Index for SRS in Brazil, through the techniques of Process Map and FMEA used in the TG100/AAPM. The study was performed in three high technology reference radiotherapy centers, two located in Rio de Janeiro city and one in Sao Paulo city. A SRS Process Map was identified for each radiotherapy center, and then FMEA technique was applied in every subprocesses identified on the map. From NPR values obtained by the FMEA a ranking of failure modes was held. Failure modes with NPR ≥ 100 and S ≥ 7 were chosen as priority to implement safety strategies. From the scores assigned to the S parameter in the implementation of FMEA a Severity Index (SI) and a Quality Index (QI) were created from an association between the NPR and the SI. The result of this study indicates that safety strategies should be implemented for the first 10 failure modes of the ranking, and a new evaluation of the process should occur every year. In addition, it is also indicated that the QI shows a minimum improvement of 9 % after the re-evaluation of the process. Overall, the study showed that the adoption of the FMEA tool together with the QI are justified as they minimize the risks to the patient, improving the quality of care and enhancing the safety Taken together the FMEA and the QI create mechanisms for ensuring that the dose will be delivered more precisely and accurately, and consequently, this increases the chances of cure or local control of the tumor, improving quality of life of the patients.
128

Avaliação da dose fetal em radioterapia de mama, com câmara de ionização cilíndrica, usando blindagem e filtros físico e dinâmico

Filipov, Danielle 10 December 2010 (has links)
Quando uma mulher grávida é submetida à radioterapia mamária, o feto pode ser gravemente afetado pela dose periférica. Com o objetivo de verificar essa dose, um objeto simulador humanóide foi irradiado na mama esquerda. O phantom é um manequim adaptado, com alguns materiais (de densidades próximas a da água) dentro e fora do mesmo. A irradiação foi feita usando feixes de raios X de energia de 6 MeV, provenientes de um acelerador linear “Clinac 600C”. Durante as irradiações, foi empregada uma blindagem, constituída de blocos e placas de chumbo, em torno da região abdominal do manequim. Além disso, foram utilizados dois tipos de filtros: físico, com angulação de 30o, e dinâmico. Através de uma câmara de ionização cilíndrica posicionada na região fetal do simulador, verificou-se que, ao final do tratamento mamário, a dose de radiação periférica atinge valores entre 3,90 e 48,67 cGy quando se irradia com o filtro físico, e entre 1,75 e 13,78 cGy para o filtro dinâmico; ambos com a blindagem. Através dos dados obtidos, conclui-se que a implantação do filtro físico incrementa a dose periférica devido ao aumento da intensidade da radiação de fuga e ao espalhamento causado pelo material atenuador. Além disso, a blindagem empregada não foi suficiente para bloquear toda radiação secundária: Ao se empregar o filtro em cunha, segundo a literatura, as doses podem ser capazes de induzir o retardo mental e o câncer durante a vida pós-nascimento. Já com o filtro dinâmico esses riscos são reduzidos drasticamente, chegando a ser ínfimos. / When a pregnant woman is submitted to breast radiotherapy, the fetus may be seriously affected by the peripheral dose. In order to verify that dose, a humanoid phantom, was irradiated at the left breast. The phantom is an adapted manikin, with some materials (densities close to water) inside and outside of it. The irradiation was done using a 6 MeV x-ray beam energy from a linear accelerator “Clinac 600C”. During the irradiation, a shield around the abdominal area of the manikin, consisting of blocks and slabs of lead was used. In addition, two types of filters were used: a physical, with 30o angulation, and an enhanced dynamic one. Through a cylindrical ionization chamber, positioned in the simulator ́s fetal region, it was found that, at the end of the breast treatment, the peripheral doses reach values between 3.90 and 48.67 cGy, when the physical wedge was used. With the application of the enhanced dynamic wedge, the values were between 1.75 and 13.78 cGy. According to the obtained data, the physical wedge can increase the peripheral dose due to the larger background radiation intensity and to the scattering caused by the attenuator material. In addition, the shielding couldn ́t block all the secondary radiation, which, according to the literature, can be able to induce mental retardation and cancer during postnatal life. However, the induction to these effects is negligible, when the type of wedge was changed.
129

Estudo e desenvolvimento de um modelo de análise de risco para Radiocirurgia intracraniana / Study and development of a risk analysis model to radiosurgery

Flávia Cristina da Silva Teixeira 17 August 2015 (has links)
Mundialmente, eventos relatados constituídos por incidentes e acidentes em radioterapia, tem aumentado ao longo dos últimos 25 anos e a maioria destes eventos são resultados de falha humana, além de terem ocorrido com maior frequência em centros sofisticados que utilizam alta tecnologia. Em radioterapia a Gestão da Qualidade necessita de uma abordagem prospectiva através de análise de risco. Esta abordagem é defendida por recentes publicações por ser atualmente uma urgência em virtude do expressivo número de acidentes ocorridos. Dada a complexidade do processo em radioterapia, a busca pela qualidade do tratamento de forma a garantir a segurança do paciente é um dos assuntos mais discutidos mundialmente. Embora apenas 14% dos centros de radioterapia no Brasil ofereçam tratamentos com a técnica de radiocirurgia intracranial (SRS), estudos relativos a qualidade do tratamento relacionada a segurança do paciente submetido à esta técnica, é de relevante importância, pois qualquer desvio da dose prescrita é considerado muito mais crítico que em outras modalidades de tratamento radioterápico, já que são utilizadas altas doses de radiação que em geral variam de 10 Gy a 40 Gy para lesões até 50 mm de diâmetro, que são aplicadas em uma única fração ou até cinco frações. Tendo em vista tais conhecimentos, o objetivo deste trabalho foi atender um novo paradigma de Gestão da Qualidade, através do desenvolvimento de um modelo de análise de risco e de um Índice de Qualidade para a SRS no Brasil, a partir da técnica de Mapa do Processo e FMEA utilizadas pelo TG 100/AAPM. O trabalho foi desenvolvido em três centros de radioterapia de referência em alta tecnologia, dois localizados no Rio de Janeiro e um em São Paulo. Um Mapa do Processo de SRS foi identificado em cada centro de radioterapia e em seguida foi aplicada a técnica FMEA para todos os subprocessos identificados no mapa. A partir dos valores de NPR obtidos pela FMEA foi realizado um ranqueamento dos modos de falha. Modos de falha com NPR ≥ 100 e S ≥ 7 foram escolhidos como prioridade para implementação de estratégias de segurança. A partir das pontuações do parâmetro S atribuídas na aplicação da FMEA foi criado o Índice de Severidade (IS) e um Índice de Qualidade (IQ) foi criado a partir de uma relação entre o NPR e o IS. O resultado deste estudo, indica que as estratégias de segurança sejam implementadas para os 10 primeiros modos de falha do ranking e uma reavaliação do processo deve ocorrer a cada 1 ano. É também indicado que o IQ obtenha uma melhora mínima de 9% após a reavaliação do processo. De forma geral, o estudo mostrou que a adoção da ferramenta FMEA juntamente com o IQ são de fato justificadas, por minimizar os riscos para o paciente, melhorando a qualidade do tratamento aprimorando a segurança, criando mecanismos que permitam a garantia de que a dose será entregue de forma precisa e exata, e consequentemente, aumentando as chances de cura ou do controle local com uma desejada qualidade de vida para estes pacientes. / The reported events in radiotherapy that constitute accidents or incidents have increased worldwide in the last 25 years. Most of these events resulted from human failure and have happened in radiotherapy centers that use high technologies. The radiotherapy Quality Management needs a prospective approach through risk analysis. This approach is supported by recent publications as this actually extremely needed due the large number of accidents. Because of the complexity of the process in radiotherapy, the search for quality of care in order to ensure patient safety is one of the most discussed topics worldwide. Although only 14% of radiotherapy centers in Brazil offer treatments with intracranial radiosurgery technique (SRS), studies about the quality of care related to the safety of patients undergoing this technique is of great importance. Any deviations from the prescribed dose using SRS technique is considered more critical than in other methods of radiation treatment, as the delivered doses in SRS are higher, in the range of 10 Gy to 40 Gy, to lesions up to 50 mm in diameter, which are delivered in a single fraction or in five fractions. In view of those information, this work aims to satisfy the new Quality Management paradigm by developing a risk analysis model, and a Quality Index for SRS in Brazil, through the techniques of Process Map and FMEA used in the TG100/AAPM. The study was performed in three high technology reference radiotherapy centers, two located in Rio de Janeiro city and one in Sao Paulo city. A SRS Process Map was identified for each radiotherapy center, and then FMEA technique was applied in every subprocesses identified on the map. From NPR values obtained by the FMEA a ranking of failure modes was held. Failure modes with NPR ≥ 100 and S ≥ 7 were chosen as priority to implement safety strategies. From the scores assigned to the S parameter in the implementation of FMEA a Severity Index (SI) and a Quality Index (QI) were created from an association between the NPR and the SI. The result of this study indicates that safety strategies should be implemented for the first 10 failure modes of the ranking, and a new evaluation of the process should occur every year. In addition, it is also indicated that the QI shows a minimum improvement of 9 % after the re-evaluation of the process. Overall, the study showed that the adoption of the FMEA tool together with the QI are justified as they minimize the risks to the patient, improving the quality of care and enhancing the safety Taken together the FMEA and the QI create mechanisms for ensuring that the dose will be delivered more precisely and accurately, and consequently, this increases the chances of cure or local control of the tumor, improving quality of life of the patients.
130

Avaliação da dose fetal em radioterapia de mama, com câmara de ionização cilíndrica, usando blindagem e filtros físico e dinâmico

Filipov, Danielle 10 December 2010 (has links)
Quando uma mulher grávida é submetida à radioterapia mamária, o feto pode ser gravemente afetado pela dose periférica. Com o objetivo de verificar essa dose, um objeto simulador humanóide foi irradiado na mama esquerda. O phantom é um manequim adaptado, com alguns materiais (de densidades próximas a da água) dentro e fora do mesmo. A irradiação foi feita usando feixes de raios X de energia de 6 MeV, provenientes de um acelerador linear “Clinac 600C”. Durante as irradiações, foi empregada uma blindagem, constituída de blocos e placas de chumbo, em torno da região abdominal do manequim. Além disso, foram utilizados dois tipos de filtros: físico, com angulação de 30o, e dinâmico. Através de uma câmara de ionização cilíndrica posicionada na região fetal do simulador, verificou-se que, ao final do tratamento mamário, a dose de radiação periférica atinge valores entre 3,90 e 48,67 cGy quando se irradia com o filtro físico, e entre 1,75 e 13,78 cGy para o filtro dinâmico; ambos com a blindagem. Através dos dados obtidos, conclui-se que a implantação do filtro físico incrementa a dose periférica devido ao aumento da intensidade da radiação de fuga e ao espalhamento causado pelo material atenuador. Além disso, a blindagem empregada não foi suficiente para bloquear toda radiação secundária: Ao se empregar o filtro em cunha, segundo a literatura, as doses podem ser capazes de induzir o retardo mental e o câncer durante a vida pós-nascimento. Já com o filtro dinâmico esses riscos são reduzidos drasticamente, chegando a ser ínfimos. / When a pregnant woman is submitted to breast radiotherapy, the fetus may be seriously affected by the peripheral dose. In order to verify that dose, a humanoid phantom, was irradiated at the left breast. The phantom is an adapted manikin, with some materials (densities close to water) inside and outside of it. The irradiation was done using a 6 MeV x-ray beam energy from a linear accelerator “Clinac 600C”. During the irradiation, a shield around the abdominal area of the manikin, consisting of blocks and slabs of lead was used. In addition, two types of filters were used: a physical, with 30o angulation, and an enhanced dynamic one. Through a cylindrical ionization chamber, positioned in the simulator ́s fetal region, it was found that, at the end of the breast treatment, the peripheral doses reach values between 3.90 and 48.67 cGy, when the physical wedge was used. With the application of the enhanced dynamic wedge, the values were between 1.75 and 13.78 cGy. According to the obtained data, the physical wedge can increase the peripheral dose due to the larger background radiation intensity and to the scattering caused by the attenuator material. In addition, the shielding couldn ́t block all the secondary radiation, which, according to the literature, can be able to induce mental retardation and cancer during postnatal life. However, the induction to these effects is negligible, when the type of wedge was changed.