Estudo da remoção de Nitrogênio Amoniacal por processo de arraste com ar (air stripping) em lixiviado de aterro sanitário.

BASTOS, F. A. 15 September 2011 (has links)
Made available in DSpace on 2018-08-24T22:53:15Z (GMT). No. of bitstreams: 1 tese_5199_Dissertação definitiva Felipe.pdf: 3695373 bytes, checksum: 835da901132eebe5561ff320277b9841 (MD5) Previous issue date: 2011-09-15 / O lixiviado de aterro sanitário possui alto potencial poluidor, com elevadas concentrações de cloretos, matéria orgânica e nitrogênio amoniacal. Seu processo de tratamento é muito complexo e geralmente envolve diferentes tecnologias. Devido à sua eficácia, o stripping é um tratamento amplamente utilizado para a remoção de NH3 de lixiviado. Esta pesquisa focou no processo de air stripping para remoção de amônia do lixiviado produzido na Central de Tratamento de Resíduos Vila Velha, CTRVV. Para tanto, as influências da variação de pH e da vazão de ar sobre a resposta do processo foram consideradas. Além disso, abordou a relação entre as remoções de alcalinidade total e nitrogênio amoniacal, bem como a formação de espuma. Para realização da parte experimental, foram realizados ensaios com 1 L de lixiviado, usando torres de arraste de com 90 cm de altura e 10 cm de diâmetro interno, em temperatura ambiente e tempo de batelada de 4 h. O experimento foi dividido em duas etapas. A Etapa I teve por objetivo direcionar metodologicamente o procedimento experimental. A Etapa II foi planejada a partir dos conhecimentos obtidos na Etapa I. Os resultados apresentaram eficiências de remoção de amônia 56%, 72% e 83% para as taxas de vazões de ar 2 NL.L-1.min-1, 5 NL.L-1.min-1 e 10 NL.L-1.min-, respectivamente. Com as variações do pH natural da amostra, pH 10, pH 11, e pH 12, obteve-se uma diferença média de 6%, entre os ensaios, sendo que o maior eficiência média foi de 75% para pH 12. Concluiu-se que a taxa de vazão de 5 NL.L-1.min-1 foi a mais adequada para remoção de amônia em lixiviado e a aplicação do pH inicial igual a 10 apresentou ser a mais vantajosa, que para pH 11 e pH 12.
2

Recuperação da amônia liberada no processo de \"air stripping\" aplicado ao tratamento do lixiviado de aterros sanitários / Recovery of ammonia released from air stripping process applied to sanitary landfill leachate treatment

Ferraz, Fernanda de Matos 26 March 2010 (has links)
O lixiviado de aterros sanitários é um efluente líquido poluente devido, principalmente, à sua elevada concentração de amônia. Seu tratamento faz-se necessário para que sejam atendidas as exigências das legislações ambiental e trabalhista, além de minimizados os impactos ambientais de seu lançamento nos corpos d\'água. Esta pesquisa propõe a remoção da amônia presente no lixiviado por meio do processo físico-químico \"air stripping\", que promove a transferência da amônia da fase líquida para gasosa. Para que não se contribua com a poluição atmosférica, o efluente gasoso do \"air stripping\" deve ser tratado em solução de ácido sulfúrico ou água. A neutralização da amônia com solução de ácido sulfúrico gera o sulfato de amônio, e com água, a aquamônia. Tais subprodutos podem ser usados como fertilizantes. Nesta pesquisa, para remoção da amônia do lixiviado foi utilizada uma torre de PVC, com 2,24 m de altura e 15 cm de diâmetro, recheada com anéis do tipo Rashing de polietileno corrugados, com diâmetro de 1,5 cm e 5 cm de comprimento. As vazões de ar utilizadas foram 1200, 1600 e 3600 L/h e as vazões de lixiviado foram 18 e 30 L/h. Para ajuste no pH do lixiviado, utilizou-se hidróxido de cálcio (padrão analítico) e cal comercial. Os fluxos de líquido e ar eram em contracorrente. Para o recolhimento da amônia foram usados dois frascos de 6 L, preenchidos com 4 L de solução de ácido sulfúrico 0,4 mol/L ou água. Os resultados obtidos indicaram remoção praticamente completa de toda a amônia contida no lixiviado. Nas diferentes condições operacionais avaliadas, a concentração de amônia remanescente no lixiviado foi igual ou inferior aos 20 mg/L determinados pela Resolução 397/08 do CONAMA. Quanto ao recolhimento da amônia, a eficiência média obtida nos frascos lavadores próxima a 80%, tanto ) quando utilizada a solução de ácido sulfúrico 0,4 mol/L quanto quando utilizada água. / Sanitary landfill leachate is a pollutant liquid effluent mainly due to its high ammonia concentration. Its treatment is necessary due to environmental and labour legislation requirements, besides prevention of environmental impacts of leachate release in water bodies. This research proposes ammonia removal from leachate by air stripping process, which transfers ammonia from liquid to gaseous phase. In order to prevent atmospheric pollution, air stripping gaseous effluent must be treated with sulphuric acid solution or water. Ammonia neutralization by sulfuric generates ammonium sulfate and by water, aquammonia is generated. Such by-products may be used as fertilizer. In this research, in order to remove leachate ammonia it was used a PVC tower of 2.24 m high and 15 cm diameter, packed with Rashing rings of corrugated polyethylene of 1.5 cm diameter and 5 cm length. Air flows were 1200, 1600 and 3600 L/h and leachete flows were 18 e 30 L/h. Calcium carbonate (standard grade) and commercial hydrated lime were used for pH adjustments. Air and liquid flows were countercurrent. In order to recover ammonia, two flasks of 6 L were used and filled with 4 L of 0.4 mol/L sulfuric acid solution or water. Results showed that ammonia was almost completely removed from leachate. In all operational conditions evaluated, remaining ammonia concentration in leachate was equal or less than 20 mg/L, value established by Resolution 397/08 of Brazilian Council of the Environment. Ammonia recovery with water or a 0.4 mol/L sulfuric acid solution was about 80%.
3

Remoção de amônia do lixiviado por arraste de ar e caracterização por fracionamento com membrana. / Removal of ammonia from the leachate by air drag and characterization by fractionation with membranes.

Rafael Gundim Silva 24 February 2011 (has links)
A proposta deste trabalho é estudar a tecnologia para a remoção de amônia do lixiviado através do processo físico-químico de arraste com ar e a sua caracterização por processos de fracionamento com membranas de MF e UF. Foram analisados no processo de arraste de ar os parâmetros pH, vazão de ar e tempo de operação. Foi verificada a remoção de nitrogênio amoniacal de 93,5% em um tempo de operação de 6 horas, com ajuste de pH igual a 11 e vazão de ar 100 L/h. Após a remoção do nitrogênio amoniacal, os lixiviados foram submetidos a processo de fracionamento com membranas de microfiltração (MF) e ultrafiltração (UF), sendo investigadas a remoção de amônia, a condutividade, DQO, COD, cloreto e pH. Obtiveram-se resultados praticamente constantes à medida que o lixiviado permeou nas membranas de MF e UF. Ademais, empregaram-se testes de toxicidade e ensaios de tratabilidade biológica com amostras de lixiviado bruto, lixiviado tratado (baixa concentração de amônia) e lixiviados fracionados com membranas de MF e UF. Nos ensaios de tratabilidade biológica os resultados mostraram que não houve uma remoção significativa de matéria orgânica e nos testes de toxicidade com organismos Danio rerio, embora tenha ocorrido uma redução na toxicidade na sequência dos experimentos, foi constatado que o lixiviado bruto, lixiviado tratado com remoção de amônia e fracionados com membranas de MF e UF mantiveram elevada toxicidade. / The proposal of present work is to study the technology for removing ammonia from leachate by physico-chemical process of air stripping and its characterization after fractionation processes with MF and UF membranes. Were analyzed the process of entrainment of air pH, air flow rate and operating time. Moreover, there was the removal of ammonia nitrogen from 93.5% in a running time of 6 hours, with pH adjustment equal to 11 and air flow rate 100 L / h. Soon after the first treatment the leachate were characterized in the process of fractionation with membranes (MF and UF) and were investigated the remotion of ammonia, conductivity, COD, COD, chloride and pH. Getting results were nearly constant as the leachate permeated the membranes of MF and UF. Moreover, were employed for toxicity tests and biological treatability tests on samples of raw leachate, leachate treatment group (low ammonia concentration) and leachates fractionated with the MF and UF membranes. In tests of biological treatability results showed no significant removal of organic matter and toxicity tests with organisms Danio rerio, besides the occurrence of a reduction in toxicity, it was found that the raw leachate, leachate treated with removal of ammonia and fractionated with the MF and UF membranes maintained high values of toxicity.
4

Remoção de amônia do lixiviado por arraste de ar e caracterização por fracionamento com membrana. / Removal of ammonia from the leachate by air drag and characterization by fractionation with membranes.

Rafael Gundim Silva 24 February 2011 (has links)
A proposta deste trabalho é estudar a tecnologia para a remoção de amônia do lixiviado através do processo físico-químico de arraste com ar e a sua caracterização por processos de fracionamento com membranas de MF e UF. Foram analisados no processo de arraste de ar os parâmetros pH, vazão de ar e tempo de operação. Foi verificada a remoção de nitrogênio amoniacal de 93,5% em um tempo de operação de 6 horas, com ajuste de pH igual a 11 e vazão de ar 100 L/h. Após a remoção do nitrogênio amoniacal, os lixiviados foram submetidos a processo de fracionamento com membranas de microfiltração (MF) e ultrafiltração (UF), sendo investigadas a remoção de amônia, a condutividade, DQO, COD, cloreto e pH. Obtiveram-se resultados praticamente constantes à medida que o lixiviado permeou nas membranas de MF e UF. Ademais, empregaram-se testes de toxicidade e ensaios de tratabilidade biológica com amostras de lixiviado bruto, lixiviado tratado (baixa concentração de amônia) e lixiviados fracionados com membranas de MF e UF. Nos ensaios de tratabilidade biológica os resultados mostraram que não houve uma remoção significativa de matéria orgânica e nos testes de toxicidade com organismos Danio rerio, embora tenha ocorrido uma redução na toxicidade na sequência dos experimentos, foi constatado que o lixiviado bruto, lixiviado tratado com remoção de amônia e fracionados com membranas de MF e UF mantiveram elevada toxicidade. / The proposal of present work is to study the technology for removing ammonia from leachate by physico-chemical process of air stripping and its characterization after fractionation processes with MF and UF membranes. Were analyzed the process of entrainment of air pH, air flow rate and operating time. Moreover, there was the removal of ammonia nitrogen from 93.5% in a running time of 6 hours, with pH adjustment equal to 11 and air flow rate 100 L / h. Soon after the first treatment the leachate were characterized in the process of fractionation with membranes (MF and UF) and were investigated the remotion of ammonia, conductivity, COD, COD, chloride and pH. Getting results were nearly constant as the leachate permeated the membranes of MF and UF. Moreover, were employed for toxicity tests and biological treatability tests on samples of raw leachate, leachate treatment group (low ammonia concentration) and leachates fractionated with the MF and UF membranes. In tests of biological treatability results showed no significant removal of organic matter and toxicity tests with organisms Danio rerio, besides the occurrence of a reduction in toxicity, it was found that the raw leachate, leachate treated with removal of ammonia and fractionated with the MF and UF membranes maintained high values of toxicity.
5

Recuperação da amônia liberada no processo de \"air stripping\" aplicado ao tratamento do lixiviado de aterros sanitários / Recovery of ammonia released from air stripping process applied to sanitary landfill leachate treatment

Fernanda de Matos Ferraz 26 March 2010 (has links)
O lixiviado de aterros sanitários é um efluente líquido poluente devido, principalmente, à sua elevada concentração de amônia. Seu tratamento faz-se necessário para que sejam atendidas as exigências das legislações ambiental e trabalhista, além de minimizados os impactos ambientais de seu lançamento nos corpos d\'água. Esta pesquisa propõe a remoção da amônia presente no lixiviado por meio do processo físico-químico \"air stripping\", que promove a transferência da amônia da fase líquida para gasosa. Para que não se contribua com a poluição atmosférica, o efluente gasoso do \"air stripping\" deve ser tratado em solução de ácido sulfúrico ou água. A neutralização da amônia com solução de ácido sulfúrico gera o sulfato de amônio, e com água, a aquamônia. Tais subprodutos podem ser usados como fertilizantes. Nesta pesquisa, para remoção da amônia do lixiviado foi utilizada uma torre de PVC, com 2,24 m de altura e 15 cm de diâmetro, recheada com anéis do tipo Rashing de polietileno corrugados, com diâmetro de 1,5 cm e 5 cm de comprimento. As vazões de ar utilizadas foram 1200, 1600 e 3600 L/h e as vazões de lixiviado foram 18 e 30 L/h. Para ajuste no pH do lixiviado, utilizou-se hidróxido de cálcio (padrão analítico) e cal comercial. Os fluxos de líquido e ar eram em contracorrente. Para o recolhimento da amônia foram usados dois frascos de 6 L, preenchidos com 4 L de solução de ácido sulfúrico 0,4 mol/L ou água. Os resultados obtidos indicaram remoção praticamente completa de toda a amônia contida no lixiviado. Nas diferentes condições operacionais avaliadas, a concentração de amônia remanescente no lixiviado foi igual ou inferior aos 20 mg/L determinados pela Resolução 397/08 do CONAMA. Quanto ao recolhimento da amônia, a eficiência média obtida nos frascos lavadores próxima a 80%, tanto ) quando utilizada a solução de ácido sulfúrico 0,4 mol/L quanto quando utilizada água. / Sanitary landfill leachate is a pollutant liquid effluent mainly due to its high ammonia concentration. Its treatment is necessary due to environmental and labour legislation requirements, besides prevention of environmental impacts of leachate release in water bodies. This research proposes ammonia removal from leachate by air stripping process, which transfers ammonia from liquid to gaseous phase. In order to prevent atmospheric pollution, air stripping gaseous effluent must be treated with sulphuric acid solution or water. Ammonia neutralization by sulfuric generates ammonium sulfate and by water, aquammonia is generated. Such by-products may be used as fertilizer. In this research, in order to remove leachate ammonia it was used a PVC tower of 2.24 m high and 15 cm diameter, packed with Rashing rings of corrugated polyethylene of 1.5 cm diameter and 5 cm length. Air flows were 1200, 1600 and 3600 L/h and leachete flows were 18 e 30 L/h. Calcium carbonate (standard grade) and commercial hydrated lime were used for pH adjustments. Air and liquid flows were countercurrent. In order to recover ammonia, two flasks of 6 L were used and filled with 4 L of 0.4 mol/L sulfuric acid solution or water. Results showed that ammonia was almost completely removed from leachate. In all operational conditions evaluated, remaining ammonia concentration in leachate was equal or less than 20 mg/L, value established by Resolution 397/08 of Brazilian Council of the Environment. Ammonia recovery with water or a 0.4 mol/L sulfuric acid solution was about 80%.

Page generated in 0.069 seconds